GH600-1.7 [TDK]
可编程电源;型号: | GH600-1.7 |
厂家: | TDK ELECTRONICS |
描述: | 可编程电源 |
文件: | 总20页 (文件大小:4830K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
™
GH1kW/1.5kW Series
Programmable DC Power Supplies
Half-Rack 1kW/1.5kW in 1U Height
! Advanced Features Built-In !
• Arbitrary Waveform Generator with Auto-Trigger Capability
• Programmable Slew Rate Control (Vout/Iout)
• Constant Power Limit Operation • Internal Resistance Programming
• Built-In Remote Isolated Analog Interface
• Built-In LAN (LXI 1.5), USB, and RS-232/RS-485 Interfaces
• Optional EtherCAT, Modbus-TCP, IEEE (488.2) Interfaces
• Blank Front Panel Option Available
2
™
The
family of programmable power supplies sets a new standard for flexible, reliable,
AC/DC power systems in OEM, Industrial and Laboratory applications.
Features include:
•
•
•
Leading DC Programmable power density (1.5kW in 1U height) in 19” Half-Rack-mount
Light-weight <3.5 kg
Wide Range of popular worldwide AC inputs:
GH1kW/1.5kW: 1ø (85~265VAC)
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Active PFC (0.99 typical)
Output Voltage up to 600V, Current up to 150A
Built-in LAN ( 1.5), USB, RS-232/RS-485 Interface
Multi-Drop capability (RS-485)
Multi-functional front panel display
Last-Setting Memory
Auto-Start / Safe-Start: user selectable
High Resolution 16 bit ADCs & DACs
Arbitrary Waveform Generator with Auto-Trigger Capability
Store up to 100 steps into four internal memory cells
High-speed Programming
Constant Voltage/Constant Current operation modes
Constant Power (CP) Limit
Slew-Rate Control (V/I)
Internal Resistance Programming Simulation
Local / Remote Sensing - software controlled
Built-In Remote Isolated Analog Program/Monitor and Control Interface
Protection functions (OVP, UVP, UVL, FOLD (CV/CC), OCL, OTP, AC FAIL)
Fan speed profile controlled by ambient temperature and load
Certified LabWindows™/CVI, LabVIEW™, and IVI Drivers
Optional EtherCAT, Modbus-TCP, IEEE (488.2) Interfaces
19" Rack Mount capability for ATE and OEM application
Scalable Power Systems
Parallel Systems with Auto-Configure
Worldwide Safety Agency approvals
CE Mark for Low Voltage, EMC and RoHS3 Directives
Five year warranty
Applications
™
power supplies have been designed to meet the demands of a wide variety of applications.
Test & Measurement systems, Component Device Testing, Manufacturing and process control.
Semiconductor Processing & Burn-In, Aerospace & Satellite Testing, Medical Imaging, Green Technology.
Higher power systems can be configured with up to four 1.5kW units.
Each unit is 1U with zero space between them (zero stack).
OEM Designers have a wide variety of Inputs and Outputs from which to select
depending on application and location.
3
GH1kW/1.5kW Front Panel Description
3
3
4
2
1
5
6
1. Input Power ON/OFF Switch
2. Air Intake allows zero stacking for maximum system flexibility and power density.
3. Reliable Detent Encoders for settings and Menu navigation.
4. High Contrast/Brightness display with wide viewing angle, 16 segment LCD
5. Function/Status LEDs: Active modes and function indicators
6. Pushbuttons allow flexible user configuration
GH1kW/1.5kW Rear Panel Description
5
4
3
2
1
10
8
12
7
6
9
11
1. Isolated Analog Programming, Monitoring and other control connector (DB26 Female)
2. USB Interface connector (Type B).
3. RS-232/RS-485 IN/OUT Remote Digital Interface (RJ-45 type) for Multi-Drop connection
4. LAN (
1.5) Interface connector (RJ-45 type with LAN status indicators).
5. Auto paralleling Bus connectors (mini I/O type) for connecting Master unit-to-Slave and Slave unit-to-Slave unit.
6. Remote/Local Output Voltage Sense Connections (spring cage).
7. Output Connections: Rugged busbars (shown) for models up to and including 100V Output;
Output connector: PHOENIX CONTACT GIC 2.5/4-G-7,62 for models with Outputs >100V.
Plug connector: PHOENIX CONTACT GIC 2.5/4-ST-7,62 for models with Outputs >100V.
8. GH1.5kW Input: 85~265VAC, Single Phase, 50/60 Hz.
AC Input Connector: PHOENIX CONTACT Power Combicon PC 5/3-G-7,62
AC Input Plug Connector: PHOENIX CONTACT Power Combicon PC 5/3-STCL1-7,62
Series with strain relief. (Model shown) GH1kW AC Input Connector: IEC320 C16.
9. Optional Interface Position for IEEE 488.2 SCPI or AnyBus Interface.
10. Exhaust air assures reliable operation when units are zero stacked.
11. Functional Ground connection (M3x8mm screw).
12. Reset button. Set default Power Supply settings.
4
Front Panel Display MENU/CONTROL buttons:
Voltage
Encoder
(Clickable)
Current
Encoder
(Clickable)
MENU buttons and
Output Control buttons
and Status LEDs
Active menu LEDs
Output ON/OFF
Status LED
Back
Alarm LED
Program
Menu
System
Menu
Voltage/Current
Preview mode
FINE
Output setting
Configurations
Menu
Communications
Menu
Protection
Menu
Front Panel Display indicators
External Voltage
Programming
External Current
Programming
Voltage Display + ‘V’ Symbol
(16 Segment)
Operation
Mode
Current Display + ‘A’ Symbol
(16 Segment)
AUTO-start
FOLDback
Voltage
Power Supply Remote Communication Active,
SAFE-start
Indicator
Address &
RS232/485, USB, LAN, OPT
(GPIB, Anybus, etc…)
Current
Power Indicator
Active
Indicator
Memory–Cell
(Sequence)
LFP (Locked Front Panel)
TRIGger
System Active
5
™
GHB1kW/1.5kW Series
Blank Front Panel (ATE version)
OUT (LED)
REM (LED)
POWER (LED)
2
3
1
A Blank Front Panel is available for applications where the front panel display and controls are not required
and only remote interface (Digital/Analog) is needed.
The Blank Front Panel option has all the standard product functions and features except the display.
The power supply can be controlled via the rear panel Remote Digital Interface
(LAN, USB, RS-232/RS-485) or via the Remote Isolated Analog Interface.
™
Parallel and Series Configurations
Standard Unit - zero stacked up to 4 units
Parallel operation - Master/Slave:
Auto paralleling Scalable Master-Slave Operation.
Active current sharing allows up to four identical units to
be connected
Total real current is programmed, measured and reported
by the Master. Up to four supplies operate as one.
Series operation
Two units may be connected in series to increase the output voltage
or to provide bipolar output. (Max 600V to Chassis Ground).
Multi-Drop Remote Programming via Communication Interface
Standard Built-in LAN, USB, RS-232 & RS-485 allows "Multi-Drop" daisy-chain control of up to 31 Power supplies
on the same communication bus. Can be daisy chained via built-in RS-485 Interface.
•
•
First unit is LAN, USB, RS-232, RS-485, etc.
All other units use RS-485 daisy chain with linking cable.
RS-485 Link
RS-485 Link
LAN, USB, RS-232, RS-485, IEEE, AnyBus
6
Graphical User Interface
Advanced "Virtual Front Panel" allows programming and monitoring unit(s) with or without front panel display.
1. Control and monitor up-to 31 units with "Address" bar
2. Front panel set-up menu control (PROGram, SYSTem, CONFiguration, PROTection and COMMunication)
3. Informative "Parameters" status bar
4. Individual unit and Global command control
5. Data logging including errors, events and recovery
6. Realtime Graph and Waveform creator, store/load sequence.
7. Solar array mode - calculate MPP (Max Peak Power) for solar array.
8. Registers View: Operation Status, Fault, Event Status, ENABLE and INTERLOCK signals.
9. Remote communication state LOC, REM, LLO.
10. Programmed signals 1&2
GUI Waveform Profile Generator
7
How to order GH1kW/1.5kW - Power Supply Identification / Accessories
GH
10 - 150
-
-
-
Series Name
Output
Output
InterfaceOptions
AC Cord Options
only for 1kW
Accessories Options
Front Panel Type
Empty: standard
B: Blank Front Panel
Voltage
(0~10V)
Current
Region: E - Europe
M - Printed *User Manual
* User Manual & GUI are
available on the website
P - Bus Parralleling Cable
(0~150A)
U - North America
J - Japan
AC Inputs (All Models)
C - China
1Ø, 85 ~ 265Vac
I - Middle East
Interface Options (Factory installed)
P/N
-
LAN (
1.5 compliant with Multi-Drop capability)- built-in
USB 2.0 compliant with Multi-Drop capability - built-in
RS-232/RS-485 - built-in
-
-
-
Isolated Analog Program/Monitor Interface
(5V/10V Pgm/Mon with 600V isolation) - built-in
IEEE (488.2 & SCPI compliant with Multi-Drop capability installed)
IEEE
MDBS
ECAT
Modbus-TCP
EtherCAT
Models 1kW
Model
Voltage (V) Current (A) Power (W)
Model
Voltage (V) Current (A) Power (W)
GH10-100
GH20-50
GH30-34
GH40-25
GH60-17
0~10V
0~20V
0~30V
0~40V
0~60V
0~100
0~50
0~34
0~25
0~17
1000
1000
1020
1000
1020
GH80-12.5
GH100-10
GH150-7
0~80V
0~12.5
0~10
0~7
1000
1000
1050
1050
1020
0~100V
0~150V
0~300V
0~600V
GH300-3.5
GH600-1.7
0~3.5
0~1.7
Models 1.5kW
Model
Voltage (V) Current (A) Power (W)
Model
Voltage (V) Current (A) Power (W)
GH10-150
GH20-75
GH30-50
GH40-38
GH60-25
0~10V
0~20V
0~30V
0~40V
0~60V
0~150
0~75
0~50
0~38
0~25
1500
1500
1500
1520
1500
GH80-19
GH100-15
GH150-10
GH300-5
GH600-2.6
0~80V
0~19
0~15
0~10
0~5
1520
1500
1500
1500
1560
0~100V
0~150V
0~300V
0~600V
0~2.6
Accessories
Rack Mounting applications P/N:GH/RM
The Rack Mounted kit allows the units to be zero stacking for maximum system flexibility and power density
without increasing the 1U height of the units To install one GH1kW/1.5kW
unit or two units side-by-side in a standard 19" rack in 1U(1.75") height,
use option kit P/N:GH/RM
Single unit installation
Single GH1kW/1.5kW power supply in a standard 19" rack in 1U(1.75") height
Dual unit installation
Two GH1kW/1.5kW power supplies side-by-side in a standard 19" rack
in 1U (1.75") height
Benchtop applications Multi Output P/N:GH/MO
The benchtop stacking kit allows the units to be Zero stacked for maximum system
flexibility and power density without increasing the 1U height of the units.
To install a GH1kW/1.5kW two units one on top of the other use option kit P/N:GH/MO-2U
8
™
GH1kW SERIES SPECIFICATIONS
OUTPUT RATING
GH
V
A
10-100
10
100
20-50
20
50
30-34
30
34
40-25
40
25
60-17
60
17
80-12.5
80
12.5
100-10
100
10
150-7
150
7
300-3.5
300
3.5
600-1.7
600
1.7
1.Rated output voltage(*1)
2.Rated output current (*2)
3.Rated output power
W
1000
1000
1020
1000
1020
1000
1000
1050
1050
1020
INPUT CHARACTERISTICS
1.Input voltage/freq. (*3)
2. Maximum Input current at 100% load (100/200)
3.Power Factor (Typ)
4.Efficiency at 100 Vac/200Vac, rated output (*17)
5.Inrush current (*5)
V
---
A
---
%
A
10
20
30
40
60
80
100
150
300
600
85~265Vac, continuous, 47~63Hz,Single Phase
12.5/6.5
0.99 @ 100Vac 0.98 @ 200Vac, rated output power.
86/88
Less than 50A
87/89
87/89
87/89
87/89
60
87/89
80
88/90
100
88/90
150
88/90
300
88/90
600
CONSTANT VOLTAGE MODE
1.Max. Line regulation (*6)
2.Max. Load regulation (*7)
3.Ripple and noise (p-p, 20MHz) (*8)
4.Ripple r.m.s. 5Hz~1MHz (*8)
5.Temperature coefficient
6.Temperature stability
V
---
---
mV
mV
10
20
30
40
0.01% of rated output voltage
0.01% of rated output voltage +2mV
50
6
50
6
50
6
60
7
60
7
75
10
75
20
75
20
200
50
500
100
PPM/°C 50PPM/°C from rated output voltage, following 30 minutes warm-up.
---
---
0.01% of rated Vout over 8hrs interval following 30 minutes warm-up. Constant line, load & temp.
Less than 0.01% of rated output voltage+2mV over 30 minutes following power on.
7. Warm-up drift
8.Remote sense compensation/wire (*10)
9.Up-prog. Response time (*11)
Full load (*12)
10.Down-prog.response time:
No load (*12)
V
2
35
30
500
2
35
30
700
5
35
60
900
5
35
60
5
35
60
5
35
60
5
40
80
5
50
120
2500
5
5
mS
mS
mS
100
220
3300
100
220
3500
1200
1500
1700
2000
Time for output voltage to recover within 0.5% of its rated output for a load change 10~90% of rated output current. Output set-point: 10~100%,
Local sense. Less than 1.5mS, for 10V models. Less than 1mS, for models up to and including 100V. 2mS for models above 100V.
11.Transient response time
mS
12.Start up delay
13.Hold-up time
Sec Less than 6 Sec
mS 20ms typical, rated output power
CONSTANT CURRENT MODE
1.Max. Line regulation (*6)
2.Max. Load regulation (*9)
3.Ripple r.m.s. @ rated voltage. B.W 5Hz~1MHz. (*13)
V
---
---
10
20
30
40
60
80
100
≤20
150
≤10
300
≤8
600
≤5
0.01% of rated output current. +2mA
0.02% of rated output current. +5mA
mA
≤420
≤160
≤100
≤60
≤50
≤30
10V~100V 100PPM/ꢀC from rated output current, following 30 minutes warm-up.
150V~600V 70PPM/ꢀC from rated output current, following 30 minutes warm-up.
0.02% of rated Iout over 8hrs. interval following 30 minutes warm-up. Constant line, load & temperature.
10V~100V model: Less than +/-0.25% of rated output current over 30 minutes following power on.
150V~600V: Less than +/-0.15% of rated output current over 30 minutes following power on.
5.Temperature coefficient
6.Temperature stability
7. Warm-up drift
PPM/°C
---
---
ANALOG PROGRAMMING AND MONITORING (ISOLATED FROM THE OUTPUT)
1.Vout voltage programming
2.Iout voltage programming (*14)
3.Vout resistor programming
4.Iout resistor programming (*14)
5.Output voltage monitor
---
---
---
---
---
---
0~100%, 0~5V or 0~10V, user selectable. Accuracy and linearity: +/-0.15% of rated Vout.
0~100%, 0~5V or 0~10V, user selectable. Accuracy and linearity: +/-0.4% of rated Iout.
0~100%, 0~5/10Kohm full scale, user selectable. Accuracy and linearity: +/-0.5% of rated Vout.
0~100%, 0~5/10Kohm full scale, user selectable. Accuracy and linearity: +/-0.5% of rated Iout.
0~5V or 0~10V, user selectable. Accuracy: +/-0.5% of rated Vout.
6.Output current monitor (*14)
0~5V or 0~10V, user selectable. Accuracy: +/-0.5% of rated Iout.
SIGNALS AND CONTROLS (ISOLATED FROM THE OUTPUT)
1. Power supply OK #1 signal
2. CV/CC signal
3. LOCAL/REMOTE Analog control
4. LOCAL/REMOTE Analog signal
5. ENABLE/DISABLE signal
---
---
---
---
---
---
---
Power supply output monitor. Open collector. Output On: On. Output Off: Off. Maximum Voltage: 30V, Maximum Sink Current: 10mA.
CV/CC Monitor. Open collector. CC mode: On. CV mode: Off. Maximum Voltage: 30V, Maximum Sink Current: 10mA.
Enable/Disable analog programming control by electrical signal or dry contact. Remote: 0~0.6V or short. Local: 2~30V or open.
analog programming control monitor signal. Open collector. Remote: On. Local: Off. Maximum Voltage: 30V, Maximum Sink Current: 10mA.
Enable/Disable PS output by electrical signal or dry contact. 0~0.6V or short, 2~30V or open. User selectable logic.
Enable/Disable PS output by electrical signal or dry contact. Remote: 0~0.6V or short. Local: 2~30V or open.
6. INTERLOCK (ILC) control
7. Programmed signals
Two open drain programmable signals. Maximum voltage 25V, Maximum sink current 100mA (Shunted by 27V zener)
Maximum low level input voltage = 0.8V,Minimum high level input voltage = 2.5V, Maximum high level input = 5V positive edge
trigger: tw=10us minimum. Tr,Tf=1us Maximum, Min delay between 2 pulses 1ms.
8. TRIGGER IN / TRIGGER OUT signals
---
9. DAISY_IN/SO control signal
10. DAISY_OUT/PS_OK #2 signal
---
---
By electrical Voltage: 0~0.6V/2~30V or dry contact.
4~5V=OK, 0V (500ohm impedance)=Fail
FUNCTIONS AND FEATURES
1. Parallel operation
2. Series operation
3. Daisy chain
4. Constant power control
5. Output resistance control
---
---
---
---
---
Possible. Up to 4 identical units in Master/Slave mode. Refer to instruction manual.
Possible. Two identical units. Refer to instruction manual.
Power supplies can be connected in Daisy chain to synchronize their turn-on and turn-off.
Limits the output power to a proggrammed value. Programming via the communication ports or the front panel.
Emulates series resistance. Resistance range: 1~1000mΩ. Programming via the communication ports or the front panel.
Programmable Output rise and Output fall slew rate. Programming range: 0.0001~999.99 V/mSec. or A/mSec. Programming via the communication
ports or the front panel.
Profiles of up to 100 steps can be stored in 4 memory cells. Activation by command via the communication ports or by the front panel.
6. Slew rate control
---
---
7. Arbitrary waveforms
PROGRAMMING AND READBACK (USB, LAN,
V
10
20
30
40
60
80
100
150
300
600
RS232/485, Optional IEEE (*16) Interfaces
1.Vout programming accuracy (*15)
2.Iout programming accuracy (*14)
3.Vout programming resolution
4.Iout programming resolution
5.Vout readback accuracy
)
---
---
---
---
---
---
%
0.05% of rated output voltage
0.1% of actual output current+0.2% of rated output current
0.002% of rated output voltage
0.0025% of rated output current
0.05% of rated output voltage
0.2% of rated output current
0.011%
0.011%
6.Iout readback accuracy (*14)
7.Vout readback resolution (of rated output voltage)
8.Iout readback resolution (of rated output current))
0.006%
0.003%
0.004%
0.004%
0.003%
0.005%
0.002%
0.007%
0.002%
0.009%
0.011%
0.011%
0.007%
0.015%
0.004%
0.004%
0.002%
0.007`%
%
9
™
GH1.5kW SERIES SPECIFICATIONS
OUTPUT RATING
GH
V
10-150
10
20-75
20
30-50
30
40-38
40
38
60-25
60
25
80-19
80
19
100-15
100
15
150-10
150
10
300-5
300
5
600-2.6
600
2.6
1.Rated output voltage(*1)
2.Rated output current (*2)
3.Rated output power
A
150
75
50
W
1500
1500
1500
1520
1500
1520
1500
1500
1500
1560
INPUT CHARACTERISTICS
1.Input voltage/freq. (*3)
2. Maximum Input current at 100% load (100/200)
3.Power Factor (Typ)
4.Efficiency at 100 Vac/200Vac, rated output (*19)
5.Inrush current (*5)
V
---
A
---
%
A
10
20
30
40
60
80
100
150
300
600
85~265Vac, continuous, 47~63Hz,Single Phase
18.5/9
0.99 @ 100Vac 0.98 @ 200Vac, rated output power.
86/88
Less than 50A
87/89
87/89
87/89
87/89
60
87/89
80
88/90
100
88/90
150
88/90
300
88/90
600
CONSTANT VOLTAGE MODE
1.Max. Line regulation (*6)
2.Max. Load regulation (*7)
3.Ripple and noise (p-p, 20MHz) (*8)
4.Ripple r.m.s. 5Hz~1MHz (*8)
5.Temperature coefficient
6.Temperature stability
V
---
---
mV
mV
10
20
30
40
0.01% of rated output voltage
0.01% of rated output voltage +2mV
50
6
50
6
50
6
60
7
60
7
75
8
130
30
75
20
180
45
500
100
PPM/°C 50PPM/°C from rated output voltage, following 30 minutes warm-up.
---
---
0.01% of rated Vout over 8hrs interval following 30 minutes warm-up. Constant line, load & temp.
Less than 0.01% of rated output voltage+2mV over 30 minutes following power on.
7. Warm-up drift
8.Remote sense compensation/wire (*10)
9.Up-prog. Response time (*11)
Full load (*12)
10.Down-prog.response time:
No load (*12)
V
2
20
20
300
2
20
20
500
5
20
20
600
5
20
30
900
5
20
30
5
20
50
5
20
50
5
30
60
5
30
70
5
40
80
mS
mS
mS
1200
1300
1700
2200
2700
3000
Time for output voltage to recover within 0.5% of its rated output for a load change 10~90% of rated output current. Output set-point: 10~100%,
Local sense. Less than 1mS, for models up to and including 100V. 2mS, for models above 100V.
11.Transient response time
mS
12.Start up delay
13.Hold-up time
Sec Less than 6 Sec
mS 20ms typical, rated output power
CONSTANT CURRENT MODE
1.Max. Line regulation (*6)
2.Max. Load regulation (*9)
3.Ripple r.m.s. @ rated voltage. B.W 5Hz~1MHz. (*13)
V
---
---
10
20
30
40
60
80
100
≤40
150
≤10
300
≤8
600
≤5
0.01% of rated output current. +2mA
0.02% of rated output current. +5mA
mA
≤250
≤130
≤100
≤60
≤50
≤30
10V~100V 100PPM/ꢀC from rated output current, following 30 minutes warm-up.
150V~600V 70PPM/ꢀC from rated output current, following 30 minutes warm-up.
0.01% of rated Iout over 8hrs. interval following 30 minutes warm-up. Constant line, load & temperature.
10V~100V model: Less than +/-0.25% of rated output current over 30 minutes following power on.
150V~600V: Less than +/-0.15% of rated output current over 30 minutes following power on.
5.Temperature coefficient
6.Temperature stability
7. Warm-up drift
PPM/°C
---
---
ANALOG PROGRAMMING AND MONITORING (ISOLATED FROM THE OUTPUT)
1.Vout voltage programming
2.Iout voltage programming (*14)
3.Vout resistor programming
4.Iout resistor programming (*14)
5.Output voltage monitor
---
---
---
---
---
---
0~100%, 0~5V or 0~10V, user selectable. Accuracy and linearity: +/-0.15% of rated Vout.
0~100%, 0~5V or 0~10V, user selectable. Accuracy and linearity: +/-0.4% of rated Iout.
0~100%, 0~5/10Kohm full scale, user selectable. Accuracy and linearity: +/-0.5% of rated Vout.
0~100%, 0~5/10Kohm full scale, user selectable. Accuracy and linearity: +/-0.5% of rated Iout.
0~5V or 0~10V, user selectable. Accuracy: +/-0.5% of rated Vout.
6.Output current monitor (*14)
0~5V or 0~10V, user selectable. Accuracy: +/-0.5% of rated Iout.
SIGNALS AND CONTROLS (ISOLATED FROM THE OUTPUT)
1. Power supply OK #1 signal
2. CV/CC signal
3. LOCAL/REMOTE Analog control
4. LOCAL/REMOTE Analog signal
5. ENABLE/DISABLE signal
---
---
---
---
---
---
---
Power supply output monitor. Open collector. Output On: On. Output Off: Off. Maximum Voltage: 30V, Maximum Sink Current: 10mA.
CV/CC Monitor. Open collector. CC mode: On. CV mode: Off. Maximum Voltage: 30V, Maximum Sink Current: 10mA.
Enable/Disable analog programming control by electrical signal or dry contact. Remote: 0~0.6V or short. Local: 2~30V or open.
analog programming control monitor signal. Open collector. Remote: On. Local: Off. Maximum Voltage: 30V, Maximum Sink Current: 10mA.
Enable/Disable PS output by electrical signal or dry contact. 0~0.6V or short, 2~30V or open. User selectable logic.
Enable/Disable PS output by electrical signal or dry contact. Remote: 0~0.6V or short. Local: 2~30V or open.
6. INTERLOCK (ILC) control
7. Programmed signals
Two open drain programmable signals. Maximum voltage 25V, Maximum sink current 100mA (Shunted by 27V zener)
Maximum low level input voltage = 0.8V,Minimum high level input voltage = 2.5V, Maximum high level input = 5V positive edge
trigger: tw=10us minimum. Tr,Tf=1us Maximum, Min delay between 2 pulses 1ms.
8. TRIGGER IN / TRIGGER OUT signals
---
9. DAISY_IN/SO control signal
10. DAISY_OUT/PS_OK #2 signal
---
---
By electrical Voltage: 0~0.6V/2~30V or dry contact.
4~5V=OK, 0V (500ohm impedance)=Fail
FUNCTIONS AND FEATURES
1. Parallel operation
2. Series operation
3. Daisy chain
4. Constant power control
5. Output resistance control
---
---
---
---
---
Possible. Up to 4 identical units in Master/Slave mode. Refer to instruction manual.
Possible. Two identical units. Refer to instruction manual.
Power supplies can be connected in Daisy chain to synchronize their turn-on and turn-off.
Limits the output power to a proggrammed value. Programming via the communication ports or the front panel.
Emulates series resistance. Resistance range: 1~1000mΩ. Programming via the communication ports or the front panel.
Programmable Output rise and Output fall slew rate. Programming range: 0.0001~999.99 V/mSec. or A/mSec. Programming via the communication
ports or the front panel.
Profiles of up to 100 steps can be stored in 4 memory cells. Activation by command via the communication ports or by the front panel.
6. Slew rate control
---
---
7. Arbitrary waveforms
PROGRAMMING AND READBACK (USB, LAN,
V
10
20
30
40
60
80
100
150
300
600
RS232/485, Optional IEEE (*18) Interfaces
1.Vout programming accuracy (*15)
2.Iout programming accuracy (*14)
3.Vout programming resolution
4.Iout programming resolution
5.Vout readback accuracy
)
---
---
---
---
---
---
%
0.05% of rated output voltage
0.1% of actual output current+0.2% of rated output current
0.002% of rated output voltage
0.0025% of rated output current
0.05% of rated output voltage
0.2% of rated output current
0.011%
0.01%
6.Iout readback accuracy (*14)
7.Vout readback resolution (of rated output voltage)
8.Iout readback resolution (of rated output current))
0.006%
0.002%
0.004%
0.003%
0.003%
0.003%
0.002%
0.005%
0.002%
0.006%
0.011%
0.007%
0.007%
0.015%
0.004%
0.003%
0.002%
0.004`%
%
10
™
PROTECTIVE FUNCTIONS
1.Foldback protection
GH1kW/1.5kW SERIES SPECIFICATIONS
V
10
20
30
40
60
80
100
150
300
600
Output shut-down when power supply changes mode from CV or Power Limit to CC mode or from CC or Power Limit to CV mode.
User presetable. Reset by AC input recycle in autostart mode, by Power Switch, by OUTPUT button, by rear panel or by communication.
---
2.Over-voltage protection (OVP)
3.Over -voltage programming range
4. Over-voltage programming accuracy
5.Output under voltage limit (UVL)
6.Over temperature protection
---
V
---
---
---
---
Output shut-down. Reset by AC input recycle in autostart mode, by OUTPUT button, by rear panel or by communication.
0.5~12
1~24
2~36
2~44.1
5~66.15
5~88.2
5~110.25
5~165.37
5~330.75
5~661.5
+/-1% of rated output voltage
Prevents from adjusting Vout below limit. Does not apply in analog programming. Preset by front panel or communication port.
Shuts down the output. Auto recovery by autostart mode.
Prevents adjustment of Vout below limit.
7. Output under voltage limit (UVL)
Prevents adjustment of Vout below limit. P.S output turns Off during under voltage condition. Reset by AC input recycle in autostart mode, by
Power Switch, by OUTPUT button, by rear panel or by communication.
8. Output under voltage protection (UVP)
---
FRONT PANEL
1.Control functions
---
---
---
---
---
---
---
---
---
---
---
---
Multiple options with 2 Encoders
Vout/Iout/Power Limit manual adjust
OVP/UVL/UVP manual adjust
Protection Functions - OVP, UVL,UVP, Foldback, OCL, ENA, ILC
Communication Functions - Selection of LAN,IEEE,RS232,RS485,USB or Optional communication interface.
Output ON/OFF. Front Panel Lock.
Communication Functions - Selection of Baud Rate, Address, IP and communication language.
Analog Control Functions - Selection Voltage/resistive programming, 5V/10V, 5K/10K programming
Analog Monitor Functions - Selection of Voltage/Current Monitoring 5V/10V.
Vout: 4 digits, accuracy: 0.05% of rated output voltage +/-1 count.
Iout: 4 digits, accuracy: 0.2% of rated output current +/-1 count.
OUTPUT ON, ALARM, PREVIEW, FINE, COMMUNICATION, PROTECTION,CONFIGURATION, SYSTEM, SEQUENCER.
2.Display
3.Front Panel Buttons Indications
4. Front Panel Display Indications
Voltage, Current, Power, CV, CC, CP, External Voltage, External Current, Address, LFP, Autostart, Safetstart, Foldback V/I, Remote (communication),
RS/USB/LAN/IEEE communication, Trigger, Load/Store Cell.
---
ENVIRONMENTAL CONDITIONS
1.Operating temperature
2.Storage temperature
3.Operating humidity
4.Storage humidity
---
---
%
0~50°C, 100% load.
-30~85°C
20~90% RH (no condensation).
10~95% RH (no condensation).
%
5.Altitude
---
Operating: 10000ft (3000m), output current derating 2%/100m or Ta derating 1°C/100m above 2000m. Non operating: 40000ft (12000m).
MECHANICAL
1.Cooling
2.Weight
---
kg
Forced air cooling by internal fans. Air flow direction: from Front panel to power supply rear
Less than 3.5kg.
W: 214, H: 43.6, D: 432 (Without busbars and busbars cover),
W: 214, H: 43.6, D: 493 (Including busbars and busbars cover) (Refer to Outline drawing).
3.Dimensions (WxHxD)
mm
4.Vibration
5.Shock
---
---
MIL-810G, method 514.6, Procedure I, test condition Annex C - 2.1.3.1
Less than 20G, half sine, 11mSec. Unit is unpacked.
SAFETY/EMC
1.Applicable standards:
Safety GH1kW/1.5kW
---
---
UL61010-1, CSA22.2 No. 61010-1, IEC61010-1, EN61010-1.
Vout≤50V Models: Output, J1, J2, J3, J4, J5, J6, J7, J8 (sense) & J9 (communication options) are Non Hazardous.
60≤Vout≤600V Models: Output & J8 (sense) are hazardous, J1, J2, J3, J4, J5, J6, J7 & J9 (communication options) are Non Hazardous.
1.1. Interface classification
GH1kW/1.5kW
Vout≤50V Models: Input – Output & J8 (sense), J1, J2, J3, J4, J5, J6, J7 & J9 (communication options): 4242VDC 1min,
Input - Ground: 2835VDC 1min.
60V≤Vout≤100V Models: Input – Output & J8 (sense), J1, J2, J3, J4, J5, J6, J7 & J9 (communication options): 4242VDC 1min,
Output & J8 (sense) - J1, J2, J3, J4, J5, J6, J7 & J9 (communication options): 850VDC 1min.
Output & J8 (sense) - Ground: 1500VDC 1min, Input - Ground: 2835VDC 1min.
100V<Vout≤600V Models: Input – Output & J8 (sense), J1, J2, J3, J4, J5, J6, J7 and J9 (communication options): 4242VDC 1min.
Output & J8 (sense) - J1, J2, J3, J4, J5, J6, J7 & J9 (communication options): 1275VDC 1min.
Output & J8 (sense) - Ground: 2500VDC 1min.
1.2 Withstand voltage
GH1kW/1.5kW
---
Input - Ground: 2835VDC 1min.
1.3 Insulation resistance
2.Conducted emmision
3.Radiated emission
4. EMC compliance
---
---
---
---
100Mohm at 25ºC, 70%RH. Output to Ground 500VDC
IEC/EN61204-3 Industrial environment, Annex H table H.1 , FCC Part 15-A, VCCI-A.
IEC/EN61204-3 Industrial environment, Annex H table H.3 and H4, FCC Part 15-A, VCCI-A
IEC/EN61204-3 Industrial environment
EMC (*4)
Unless otherwise noted, specifications are warranted over the ambient temperature range of 0° to 50°C
NOTES:
*1: Minimum voltage is guaranteed to maximum 0.1% of rated output voltage.
*2: Minimum current is guaranteed to maximum 0.2% of rated output current.
*3: For cases where conformance to various safety standards (UL, IEC, etc…) is required, to be described as 100-240Vac (50/60Hz).
*4: Signal and control ports interface cables length: Less than 3m, DC output power port cables length: Less than 30m.
*5: Not including EMI filter inrush current, less than 0.2mSec.
*6: 85~132Vac or 170~265Vac. Constant load.
*7: From No-Load to Full-Load, constant input voltage. Measured at the sensing point in Remote Sense.
*8: For 10V~150V models: Measured with JEITA RC-9131C (1:1) probe. For 200~600V model: Measured with 100:1 probe.
*9: For load voltage change, equal to the unit voltage rating, constant input voltage.
*10: The maximum voltage on the power supply terminals must not exceed the rated voltage.
*11: From 10% to 90% of Rated Output Voltage, with rated, resistive load.
*12: From 90% to 10% of Rated Output Voltage.
*13: For 10V model, the ripple is measured at 20~100% of rated output voltage and rated output current. For other models, the ripple is measured at 10~100% of rated output
voltage and rated output current. B.W 5Hz~1MHz.
*14: The Constant Current programming, readback and monitoring accuracy do not include the warm-up and Load regulation thermal drift.
*15: Measured at the sensing point.
*16 Max. ambient temperature for using IEEE is 40°C.
*17: Ta=25°C, rated output power.
11
Outline Drawing
GH1kW (10V-100V)
™
12
Outline Drawing
GH1kW (150V-600V)
™
13
Outline Drawing
GHB1kW
™
14
Outline Drawing
GH1.5kW (10V-100V)
™
15
Outline Drawing
GH1.5kW (150V-600V)
™
16
Outline Drawing
GHB1.5kW
™
17
18
19
NORTH AMERICA
Denmark
TDK-Lambda Americas Inc
TDK-Lambda Nordic
Haderslevvej 36B, DK-6000 Kolding, Denmark
TEL: +45-8853-8086
E-mail: info@dk.tdk-lambda.com
www.emea.lambda.tdk.com/dk
405 Essex Rd. Neptune, NJ 07753
Tel: +1-732-922-9300 Fax: +1-732-922-1441
E-mail: sales@us.tdk-lambda.com
www.us.lambda.tdk.com
UK
JAPAN
TDK-Lambda UK Ltd.
Kingsley Avenue Ilfracombe, Devon
EX 34 8ES, United Kingdom
TDK-Lambda Corporation
Nihonbashi Takashimaya Mitsui Bldg. 2-5-1 Nihonbashi,
Chuo-ku, Tokyo 103-6128, JAPAN
Tel: +44-1271-856666 Fax: +44-1271-864894
E-mail: info@uk.tdk-lambda.com
www.emea.lambda.tdk.com/uk
TEL: +81-3-6778-1113 FAX: +81-3-6778-1160
www.jp.lambda.tdk.com
CHINA
FRANCE
TDK-Lambda (China) Electronics Co. Ltd,
Shanghai Office 5th Floor Kehui Tower, 1188 Qinzhou Road (North),
Xuhui District Shanghai 200233, China
TDK-Lambda France SAS
3 Avenue du Canada,
Parc Technopolis - Bâtiment Sigma,
91940 Les Ulis – France CS 41077
Tel: +33 1 60 12 71 65 Fax: +33 1 60 12 71 66
E-mail: france@fr.tdk-lambda.com
www.emea.lambda.tdk.com/fr
Tel: +86-21-6485-0777 Fax: +86-21-6485-0666
www.lambda.tdk.com.cn
Beijing Branch of TDK-Lambda (China) Electronic Co. Ltd.
Room 12B11-12B12, Unit 7 Dacheng square, No.28
Xuanwumenxi Street, Xuanwu District Beijing, 100053, CHINA
Tel: +86-10-6310-4872 Fax: +86-10-6310-4874
www.lambda.tdk.com.cn
GERMANY
TDK-Lambda Germany GmbH
Karl-Bold-Str.40,
D-77855 Achern, Germany
Tel: +49-7841-666-0 Fax: +49-7841-500-0
E-mail: info.germany@de.tdk-lambda.com
www.emea.lambda.tdk.com/de
Shenzhen Branch of TDK-Lambda (China) Electronics Co.Ltd.
69/F, Ping An Finance Centre, 5033 Yitian Road,
Futian District, Shenzhen,China
Tel: +86-755-83588261 Fax: +86-755-83588260
www.lambda.tdk.com.cn
AUSTRIA
KOREA
TDK-Lambda Germany GmbH Austria Sales Office
Aredstrasse 22, 2544 Leobersdorf, Austria
Tel: +43-2256-65584 Fax: +43-2256-64512
E-mail: info@at.tdk-lambda.com
TDK-Lambda Corporation Korea Branch
Seocho-Dong,12F. Songnam Bldg. 273, Gangnam Daero,
Seocho-Gu, Seoul 06730, Republic of Korea
Tel: +82-2-3473-7051 Fax: +82-2-3472-9137
www.lambda.tdk.co.kr
www.emea.lambda.tdk.com/at
ITALY
SINGAPORE
TDK-Lambda France Sas Succursale Italiana
Via Giacomo Matteotti 62,
20092 Cinisello Balsamo (MI), Italia
Tel: +39-02-6129-3863 Fax: +39-02-6129-0900
E-mail: info.italia@it.tdk-lambda.com
www.emea.lambda.tdk.com/it
TDK-Lambda Singapore Pte.Ltd.
Blk 1008 Toa Payoh North # 07-01/03
Singapore 318996
Tel: +65-6251-7211 Fax: +65-6250-9171
www.sg.lambda.tdk.com
INDIA
ISRAEL
TDK India Private Limited. Power Supply Division
#87, The Centrum, 4th Floor, Infantry Road, Bengaluru,
Karnataka, -560 001, INDIA
TDK-Lambda Ltd.
Sales Office: Alexander Yanai 1, Petah Tikva, 4927701, ISRAEL
Tel: +972-3-9024-333 Fax: +972-3-9024-777
Tel: +91-80-40390660 Fax: +91-80-40390603
Plant: 56 Haharoshet St.,
MALAYSIA
Karmiel Industrial Zone 2165158, Israel
Tel: +972-4-9887-491 Fax: +972- 4-9583-071
www.emea.lambda.tdk.com/il E-mail: info@tdk-lambda.co.il
TDK-Lambda Malaysia Sdn. Bhd. (Nilai Office)
c/o TDK (Malaysia) Sdn. Bhd., Lot 709, Nilai Industrial Estate
71800 Nilai, Negeri Sembilan, MALAYSIA
Switzerland
TEL: +60-6-797-8800 Fax: +60-6-797-8966
TDK-Lambda Germany GmbH
Switzerland Sales Office, Eichtalstr. 55
8634 Hombrechtikon - Switzerland
Tel: +41 44 850 53 53
E-mail: info@ch.tdk-lambda.com
www.emea.lambda.tdk.com/ch
https://product.tdk.com/en/power
www.emea.lambda.tdk.com
相关型号: