JAH05-20R [TDK]
AC-DC Regulated Power Supply Module, 1 Output, 100W, 222 X 75 MM, 35 MM HEIGHT, MODULE;型号: | JAH05-20R |
厂家: | TDK ELECTRONICS |
描述: | AC-DC Regulated Power Supply Module, 1 Output, 100W, 222 X 75 MM, 35 MM HEIGHT, MODULE |
文件: | 总9页 (文件大小:510K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
JAH Series
Power Supplies
AC Input
Single Output, General-Purpose
FEATURES
• Low profile, single output AC.200V input power supply.
• Small open frame.
• These low noise power supplies are FCC/VDE class
B standards compliant.
• Low price.
PART NUMBERS AND RATINGS
10W type
Current(A)
2
0.84
0.67
15W type
Current(A)
3
1.3
1
25W type
Current(A)
5
2.1
1.7
1.1
Output voltage(V)
Part No.
Part No.
JAH05-3R0
JAH12-1R3
JAH15-1R0
JAH24-R63
Part No.
5
JAH05-2R0
JAH12-R84
JAH15-R67
JAH24-R42
JAH05-5R0
JAH12-2R1
JAH15-1R7
JAH24-1R1
12
15
24
0.42
0.63
50W type
Current(A)
10
4.2
3.4
100W type
Current(A)
20
8.4
6.7
4.2
150W type
Current(A)
30
12.5
10
Output voltage(V)
Part No.
Part No.
Part No.
5
JAH05-10R
JAH12-4R2
JAH15-3R4
JAH24-2R1
JAH05-20R
JAH12-8R4
JAH15-6R7
JAH24-4R2
JAH05-30R
JAH12-13R
JAH15-10R
JAH24-6R3
12
15
24
2.1
6.3
Specifications which provide more details for the proper and safe use of the described product are available upon request.
All specifications are subject to change without notice.
JAH Series
Power Supplies
AC Input
Single Output, General-Purpose
SPECIFICATIONS
10W TYPE
Part No.
JAH05-2R0
5V • 2A
10
JAH12-R84
12V • 0.84A
10.1
JAH15-R67
15V • 0.67A
10.1
JAH24-R42
24V • 0.42A
10.1
1
Output voltage, current
Maximum output power
Input requirements
W
2
Input voltage Eac
Input frequency
Input current
V
Hz
A
170 to 265[Rating:200-240]
47 to 66[Single phase]
0.2max.[200V]
Fuse rating
A
1.25[Internal]
Surge current
A
20max.[200V]
Leakage current
Efficiency
mA
%
0.75max.[240V, operating]
71typ.
73typ.
73typ.
73typ.
Output characteristics
Output voltage
Voltage variable range
Maximum output current
Overvoltage threshold
Overcurrent threshold
V
V
A
V
A
%
%
5
12
15
24
4.5 to 5.5
2
5.6 to 6.9
2.1min.
10.8 to 13.2
0.84
13.4 to 15.7
0.9min.
13.5 to 16.5
0.67
16.7 to 19
0.7min.
21.6 to 26.4
0.42
26.7 to 30.5
0.44min.
1
Input variation
Load variation
Temperature
variation
2max.(1typ.)[Within the input voltage range]
2max.(1typ.)[10 to 100% load]
Total variation ±3max.(±1typ.)
Voltage stability
%
2max.(1typ.)[0 to +40°C]
Drift
Dynamic load
%
0.5max.(0.1typ.)[After input voltage ON for 30min to 8h]
±4max./1max.[50 to 100% sudden load change]
%/ms
mV
ms
Ripple noise Ep-p
Start up time
120max.
190max.
220max.
310max.
400max.[200V]
30min.(42typ.)[200V]
Hold up time
ms
Accessory equipment
Operation indicator
Overvoltage protection
Overcurrent protection
Remote ON-OFF
Remote sensing
Output voltage external variable
function
None
Voltage shielding type, recovers upon reset(interval approx. 40s).
Fixed current and voltage threshold type, automatic recovery, but overcurrent of 1s min. is shielded.
None
None
None
Standards
Safety standards
Noise terminal voltage
Construction
EN60950(TÜV) approved.
VCCI class 2, FCC class B, VDE class B compliant.
External dimensions H×W×L
Weight
mm
g
21×60×120
110max.
Mounting method
1 side (Open frame)
1 Current rating(maximum output current) is determined for –10 to +40°C. Derating is required when used outside this temperature range.
2 Output can stop if input voltage drops below the minimum value continuously for over 1s during supply of power to load.
Specifications which provide more details for the proper and safe use of the described product are available upon request.
All specifications are subject to change without notice.
JAH Series
Power Supplies
AC Input
Single Output, General-Purpose
SPECIFICATIONS
15W TYPE
Part No.
JAH05-3R0
5V • 3A
15
JAH12-1R3
12V • 1.3A
15.6
JAH15-1R0
15V • 1A
15
JAH24-R63
24V • 0.63A
15.1
1
Output voltage, current
Maximum output power
Input requirements
W
2
Input voltage Eac
Input frequency
Input current
V
Hz
A
170 to 265[Rating:200-240]
47 to 66[Single phase]
0.25max.[200V]
Fuse rating
A
1.25[Internal]
Surge current
Leakage current
Efficiency
A
mA
%
20max.[200V, 25°C, cold start]
0.75max.[240V, operating]
72typ.
76typ.
76typ.
77typ.
Output characteristics
Output voltage
Voltage variable range
Maximum output current
Overvoltage threshold
Overcurrent threshold
V
V
A
V
A
%
%
5
12
15
24
4.5 to 5.5
3
5.6 to 6.9
3.2min.
10.8 to 13.2
1.3
13.4 to 15.7
1.4min.
13.5 to 16.5
1
16.7 to 19
1.05min.
21.6 to 26.4
0.63
26.7 to 30.5
0.66min.
1
Input variation
Load variation
Temperature
variation
2max.(1typ.)[Within the input voltage range]
2max.(1typ.)[10 to 100% load]
Total variation ±3max.(±1typ.)
Voltage stability
%
2max.(1typ.)[0 to +40°C]
Drift
Dynamic load
%
0.5max.(0.1typ.)[After input voltage ON for 30min to 8h]
±4max./1max.[50 to 100% sudden load change]
%/ms
mV
ms
Ripple noise Ep-p
Start up time
120max.
190max.
220max.
310max.
400max.[200V]
18min.(25typ.)[200V]
Hold up time
ms
Accessory equipment
Operation indicator
Overvoltage protection
Overcurrent protection
Remote ON-OFF
Remote sensing
Output voltage external variable
function
None
Voltage shielding type, recovers upon reset(interval approx. 40s).
Fixed current and voltage threshold type, automatic recovery, but overcurrent of 1s min. is shielded.
None
None
None
Standards
Safety standards
Noise terminal voltage
Construction
EN60950(TÜV3) approved.
VCCI class 2, FCC class B, VDE class B compliant.
External dimensions H×W×L
Weight
mm
g
21×60×120
110max.
Mounting method
1 side (Open frame)
1 Current rating(maximum output current) is determined for –10 to +40°C. Derating is required when used outside this temperature range.
2 Output can stop if input voltage drops below the minimum value continuously for over 1s during supply of power to load.
Specifications which provide more details for the proper and safe use of the described product are available upon request.
All specifications are subject to change without notice.
JAH Series
Power Supplies
AC Input
Single Output, General-Purpose
SPECIFICATIONS
25W TYPE
Part No.
JAH05-5R0
5V • 5A
25
JAH12-2R1
12V • 2.1A
25.2
JAH15-1R7
15V • 1.7A
25.5
JAH24-1R1
24V • 1.1A
26.4
1
Output voltage, current
Maximum output power
Input requirements
W
2
Input voltage Eac
Input frequency
Input current
V
Hz
A
170 to 265[Rating:200-240]
47 to 66[Single phase]
0.35max.[200V ]
Fuse rating
A
1.6[Internal ]
Surge current
Leakage current
Efficiency
A
mA
%
30max.[200V, 1st surge current]
0.75max.[240V, operating]
77typ.
77typ.
79typ.
80typ.
Output characteristics
Output voltage
Voltage variable range
Maximum output current
Overvoltage threshold
Overcurrent threshold
V
V
A
V
A
%
%
5
12
15
24
4.5 to 5.5
5
5.6 to 6.9
5.3min.
10.8 to 13.2
2.1
13.4 to 15.7
2.2min.
13.5 to 16.5
1.7
16.7 to 19
1.8min.
21.6 to 26.4
1.1
26.7 to 30.5
1.2min.
1
Input variation
Load variation
Temperature
variation
2max.(1typ.)[Within the input voltage range]
2max.(1typ.)[10 to 100% load]
Total variation ±3max.(±1typ.)
Voltage stability
%
2max.(1typ.)[0 to +40°C]
Drift
Dynamic load
%
0.5max.(0.1typ.)[After input voltage ON for 30min to 8h]
±4max./1max.[50 to 100% sudden load change]
%/ms
mV
ms
Ripple noise Ep-p
Start up time
120max.
190max.
220max.
310max.
500max.[200V]
27min.(35typ.)[200V]
Hold up time
ms
Accessory equipment
Operation indicator
Overvoltage protection
Overcurrent protection
Remote ON-OFF
Remote sensing
Output voltage external variable
function
None
Voltage shielding type, recovers upon reset(interval approx. 40s).
Fixed current and voltage threshold type, automatic recovery, but overcurrent of 1s min. is shielded.
None
None
None
Standards
Safety standards
Noise terminal voltage
Construction
EN60950(TÜV) approved.
VCCI class 2, FCC class B, VDE class B compliant.
External dimensions H×W×L
Weight
mm
g
25×60×143
160max.
Mounting method
1 side (Open frame)
1 Current rating(maximum output current) is determined for –10 to +40°C. Derating is required when used outside this temperature range.
2 Output can stop if input voltage drops below the minimum value continuously for over 1s during supply of power to load.
Specifications which provide more details for the proper and safe use of the described product are available upon request.
All specifications are subject to change without notice.
JAH Series
Power Supplies
AC Input
Single Output, General-Purpose
SPECIFICATIONS
50W TYPE
Part No.
JAH05-10R0
5V • 10A
50
JAH12-4R2
12V • 4.2A
50.4
JAH15-3R4
15V • 3.4A
51
JAH24-2R1
24V • 2.1A
50.4
1
Output voltage, current
Maximum output power
Input requirements
W
2
Input voltage Eac
Input frequency
Input current
V
Hz
A
170 to 265[Rating:200-240]
47 to 66[Single phase]
0.65max.[200V ]
Fuse rating
A
2[Internal ]
Surge current
Leakage current
Efficiency
A
mA
%
30max.[200V, 25°C, cold start]
0.75max.[240V, operating]
80typ.
80typ.
82typ.
83typ.
Output characteristics
Output voltage
Voltage variable range
Maximum output current
Overvoltage threshold
Overcurrent threshold
V
V
A
V
A
%
%
5
12
15
24
4.5 to 5.5
10
5.6 to 6.9
10.5min.
10.8 to 13.2
4.2
13.4 to 15.7
4.4min.
13.5 to 16.5
3.4
16.7 to 19
3.5min.
21.6 to 26.4
2.1
26.7 to 30.5
2.2min.
1
Input variation
Load variation
Temperature
variation
2max.(1typ.)[Within the input voltage range]
2max.(1typ.)[10 to 100% load]
Total variation ±3max.(±1typ.)
Voltage stability
%
2max.(1typ.)[0 to +40°C]
Drift
Dynamic load
%
0.5max.(0.1typ.)[After input voltage ON for 30min to 8h]
±4max./1max.[50 to 100% sudden load change]
%/ms
mV
ms
Ripple noise Ep-p
Start up time
120max.
190max.
220max.
310max.
500max.[200V]
17min.(25typ.)[200V]
Hold up time
ms
Accessory equipment
Operation indicator
Overvoltage protection
Overcurrent protection
Remote ON-OFF
Remote sensing
Output voltage external variable
function
None
Voltage shielding type, recovers upon reset(interval approx. 40s).
Fixed current and voltage threshold type, automatic recovery, but overcurrent of 1s min. is shielded.
None
None
None
Standards
Safety standards
Noise terminal voltage
Construction
EN60950(TÜV) approved.
VCCI class 2, FCC class B, VDE class B compliant.
External dimensions H×W×L
Weight
mm
g
30×60×185
240max.
Mounting method
1 side (Open frame)
1 Current rating(maximum output current) is determined for –10 to +40°C. Derating is required when used outside this temperature range.
2 Output can stop if input voltage drops below the minimum value continuously for over 1s during supply of power to load.
Specifications which provide more details for the proper and safe use of the described product are available upon request.
All specifications are subject to change without notice.
JAH Series
Power Supplies
AC Input
Single Output, General-Purpose
SPECIFICATIONS
100W TYPE
Part No.
JAH05-20R
5V • 20A
100
JAH12-8R4
12V • 8.4A
100.8
JAH15-6R7
15V • 6.7A
100.5
JAH24-4R2
24V • 4.2A
100.8
1
Output voltage, current
Maximum output power
Input requirements
Input voltage Eac
Input frequency
Input current
W
V
Hz
A
170 to 265[Rating:200-240]
47 to 66[Single phase]
1.5max.[200V]
Fuse rating
A
3.15[Internal]
Surge current
Leakage current
Efficiency
A
mA
%
30max.[200V, 1st surge current, reset after roughly 10s min.]
0.75max.[240V, operating]
81typ.
84typ.
85typ.
87typ.
Output characteristics
Output voltage
Voltage variable range
Maximum output current
Overvoltage threshold
Overcurrent threshold
V
V
A
V
A
%
%
5
12
15
24
4.5 to 5.5
20
5.6 to 6.9
21min.
10.8 to 13.2
8.4
13.4 to 15.7
8.9min.
13.5 to 16.5
6.7
16.7 to 19
7.1min.
21.6 to 26.4
4.2
26.7 to 30.5
4.5min.
1
Input variation
Load variation
Temperature
variation
2max.(1typ.)[Within the input voltage range]
2max.(1typ.)[10 to 100% load]
Total variation ±3max.(±1typ.)
Voltage stability
%
2max.(1typ.)[0 to +40°C]
Drift
Dynamic load
%
0.5max.(0.1typ.)[After input voltage ON for 30min to 8h]
±4max./1max.[50 to 100% sudden load change]
%/ms
mV
ms
Ripple noise Ep-p
Start up time
120max.
190max.
220max.
310max.
250max.[200V]
27min.(35typ.)[200V]
Hold up time
ms
Accessory equipment
Operation indicator
Overvoltage protection
Overcurrent protection
Remote ON-OFF
Remote sensing
None
Voltage shielding type, recovers upon reset(interval approx. 40s).
Fixed current and voltage threshold type, automatic recovery, but overcurrent of 1s min. is shielded.
None
None
None
2
Output voltage external variable function
Standards
Safety standards
EN60950(TÜV) approved.
Noise terminal voltage
Construction
VCCI class 2, FCC class B, VDE class B compliant.
External dimensions H×W×L
Weight
mm
g
35×75×222
550max.
Mounting method
1 side (Open frame)
1 Current rating(maximum output current) is determined for –10 to +40°C. Derating is required when used outside this temperature range.
2 The power supply can be damaged if output current exceeds the rated value, and the overload condition(output current that is greater than the output
current rating and less than the overcurrent detection threshold) continues for 1min minimum.
Specifications which provide more details for the proper and safe use of the described product are available upon request.
All specifications are subject to change without notice.
JAH Series
Power Supplies
AC Input
Single Output, General-Purpose
SPECIFICATIONS
150W TYPE
Part No.
JAH05-30R
5V • 30A
150
JAH12-13R
12V • 12.5A
150
JAH15-10R
15V • 10A
150
JAH24-6R3
24V • 6.3A
151.2
1
Output voltage, current
Maximum output power
Input requirements
Input voltage Eac
Input frequency
Input current
W
V
Hz
A
170 to 265[Rating:200-240]
47 to 66[Single phase]
1.95max.[200V]
Fuse rating
A
3.15[Internal]
Surge current
Leakage current
Efficiency
A
mA
%
30max.[200V, 1st surge current, reset after roughly 10s min.]
0.75max.[240V, operating]
82typ.
83typ.
84typ.
86typ.
Output characteristics
Output voltage
Voltage variable range
Maximum output current
Overvoltage threshold
Overcurrent threshold
V
V
A
V
A
%
%
5
12
15
24
4.5 to 5.5
30
5.6 to 6.9
31.5min.
10.8 to 13.2
12.5
13.4 to 15.7
13.2min.
13.5 to 16.5
10
16.7 to 19
10.5min.
21.6 to 26.4
6.3
26.7 to 30.5
6.7min.
1
Input variation
Load variation
Temperature
variation
2max.(1typ.)[Within the input voltage range]
2max.(1typ.)[10 to 100% load]
Total variation ±3max.(±1typ.)
Voltage stability
%
2max.(1typ.)[0 to +40°C]
Drift
Dynamic load
%
0.5max.(0.1typ.)[After input voltage ON for 30min to 8h]
±4max./1max.[50 to 100% sudden load change]
%/ms
mV
ms
Ripple noise Ep-p
Start up time
120max.
190max.
220max.
310max.
250max.[200V]
30min.(40typ.)[200V]
Hold up time
ms
Accessory equipment
Operation indicator
Overvoltage protection
Overcurrent protection
Remote ON-OFF
Remote sensing
None
Voltage shielding type, recovers upon reset(interval approx. 40s).
Fixed current and voltage threshold type, automatic recovery, but overcurrent of 1s min. is shielded.
None
None
2
Output voltage external variable
function
None
Standards
Safety standards
Noise terminal voltage
Construction
EN60950(TÜV) approved.
VCCI class 2, FCC class B, VDE class B compliant.
External dimensions H×W×L
Weight
mm
g
40×85×222
620max.
Mounting method
1 side (Open frame)
1 Current rating(maximum output current) is determined for –10 to +40°C. Derating is required when used outside this temperature range.
2
The power supply can be damaged if output current exceeds the rated value, and the overload condition(output current that is greater than the output
current rating and less than the overcurrent detection threshold) continues for 1min minimum.
Specifications which provide more details for the proper and safe use of the described product are available upon request.
All specifications are subject to change without notice.
JAH Series
Power Supplies
AC Input
Single Output, General-Purpose
TERMINAL DESIGNATIONS AND FUNCTIONS
JAH10W
Terminal No. 1: Input terminal(No. 1 pin of CP1)
Live line. Fuse is built in.
9 grounding pad
soldering surface
(
)
Terminal No. 2: Input terminal(No. 4 pin of CP1)
Neutral line
8 1-ø3
9 clearance
clearance
(
both product and
soldering surface
(
)
product surface
)
Terminal No. 3: Input terminal(No. 8 pin of CP1)
Ground
4-ø3.5
5
Terminal No. 4: Ground
VR
1
2
3
Connect with input terminal(No. 8 pin of CP1). If the power supply is
connected electrically to equipment via the spacer, etc., the spacer
material should be electrically conductive(spacer contact surface=6mm
max. dia.).
6
7
Terminal No. 5: Output voltage adjustment
Clockwise rotation increases output voltage.
Terminal No. 6: + output terminal(No. 2 pin of CP51)
Terminal No. 7: – output terminal(No. 1 pin of CP51)
Terminal No. 8: Spacer mounting hole
4
9 grounding pad
soldering surface
9 grounding pad
soldering surface
(
)
(
)
clearance
clearance
A
spacer should be used that is constructed from an insulating
(
)
(
)
product surface
product surface
material(spacer contact surface=6mm max. dia.).
JAH15W
Terminal No. 1: Input terminal(No. 1 pin of CP1)
Live line. Fuse is built in.
9 grounding pad
(
)
Terminal No. 2: Input terminal(No. 4 pin of CP1)
Neutral line
soldering surface
8 1-ø3
9 clearance
clearance
(
both product and
soldering surface
(
)
product surface
)
Terminal No. 3: Input terminal(No. 8 pin of CP1)
Ground
4-ø3.5
VR
1
2
3
Terminal No. 4: Ground
5
6
7
Connect with input terminal(No. 8 pin of CP1). If the power supply is
connected electrically to equipment via the spacer, etc., the spacer
material should be electrically conductive(spacer contact surface=6mm
max. dia.).
Terminal No. 5: Output voltage adjustment
Clockwise rotation increases output voltage.
Terminal No. 6: + output terminals(No. 3 and 4 pins of CP51)
Terminal No. 7: – output terminals(No. 1 and 2 pins of CP51)
Terminal No. 8: Spacer mounting hole
4
9 grounding pad
soldering surface
9 grounding pad
soldering surface
(
)
(
)
clearance
clearance
(
)
product surface
(
)
product surface
A
spacer should be used that is constructed from an insulating
material(spacer contact surface=6mm max. dia.).
Terminal No. 1: Input terminal(No. 6 pin of CP1)
Live line. Fuse is built in.
JAH25W
9 clearance
Terminal No. 2: Input terminal(No. 4 pin of CP1)
Neutral line
9 clearance
(
both product and
soldering surface
5
(
both product and
soldering surface
)
)
Terminal No. 3: Input terminal(No. 1 pin of CP1)
Ground
4-ø3.5
VR
1
2
Terminal No. 4: Ground
Connect with input terminal(No. 1 pin of CP1). If the power supply is
connected electrically to equipment via the spacer, etc., the spacer
material should be electrically conductive(spacer contact surface=6mm
max. dia.).
3
4
6
7
Terminal No. 5: Output voltage adjustment
Clockwise rotation increases output voltage.
Terminal No. 6: + output terminals(No. 1 and 2 pins of CP51)
Terminal No. 7: – output terminals(No. 3 and 4 pins of CP51)
Terminal No. 8: Spacer mounting hole
8 1-ø3
9 clearance
9 grounding pad
soldering surface
(
)
(
both product and
soldering surface
clearance
)
(
)
product surface
A
spacer should be used that is constructed from an insulating
Dimensions in mm
material(spacer contact surface=6mm max. dia.).
Specifications which provide more details for the proper and safe use of the described product are available upon request.
All specifications are subject to change without notice.
JAH Series
Power Supplies
AC Input
Single Output, General-Purpose
TERMINAL DESIGNATIONS AND FUNCTIONS
JAH50W
Terminal No. 1: Input terminal(No. 6 pin of CP1)
Live line. Fuse is built in.
Terminal No. 2: Input terminal(No. 4 pin of CP1)
Neutral line
9 clearance
8 1-ø3
9 clearance
(
both product and
(
both product and
soldering surface
)
soldering surface
)
Terminal No. 3: Input terminal(No. 1 pin of CP1)
Ground
Terminal No. 4: Ground
Connect with input terminal(No. 1 pin of CP1). If the power supply is
connected electrically to equipment via the spacer, etc., the spacer
material should be electrically conductive(spacer contact surface=6mm
max. dia.).
4-ø3.5
1
2
3
6
7
Terminal No. 5: Output voltage adjustment
Clockwise rotation increases output voltage.
Terminal No. 6: + output terminals(No. 1 and 2 pins of CP51)
Terminal No. 7: – output terminals(No. 3 and 4 pins of CP51)
Terminal No. 8: Spacer mounting hole
4
4
9 grounding pad
9 grounding pad
(
)
soldering surface
clearance
5
(
)
soldering surface
clearance
(
)
product surface
(
)
product surface
A
spacer should be used that is constructed from an insulating
material(spacer contact surface=6mm max. dia.).
Terminal No. 1: Input terminal(No. 6 pin of CP1)
Live line. Fuse is built in.
Terminal No. 2: Input terminal(No. 4 pin of CP1)
Neutral line
Terminal No. 3: Input terminal(No. 1 pin of CP1)
Ground
Terminal No. 4: Ground
JAH100W
9 grounding pad
soldering surface
9 grounding pad
soldering surface
(
)
(
)
8 1-ø3
clearance
clearance
5
(
)
product surface
(
)
product surface
1
2
4-ø3.5
6
Connect with input terminal(No. 1 pin of CP1). If the power supply is
connected electrically to equipment via the spacer, etc., the spacer
material should be electrically conductive(spacer contact surface=6mm
max. dia.).
3
7
Terminal No. 5: Output voltage adjustment
Clockwise rotation increases output voltage.
Terminal No. 6: + output terminals(No. 1 to 4 pins of CP51)
Terminal No. 7: – output terminals(No. 5 to 8 pins of CP51)
Terminal No. 8: Spacer mounting hole
4
9 grounding pad
soldering surface
9 grounding pad
soldering surface
(
)
(
)
A spacer should be used that is constructed from an insulating
material(spacer contact surface=6mm max. dia.).
clearance
clearance
(
)
(
)
product surface
product surface
JAH150W
Terminal No. 1: Input terminal(No. 6 pin of CP1)
Live line. Fuse is built in.
Terminal No. 2: Input terminal(No. 4 pin of CP1)
Neutral line
Terminal No. 3: Input terminal(No. 1 pin of CP1)
Ground
Terminal No. 4: Ground
9 clearance
9 clearance
4-ø3.5
(
(
both product and
)
soldering surface
both product and
soldering surface
9 10
)
4
5
6
1
2
Connect with input terminal(No. 1 pin of CP1). If the power supply is
connected electrically to equipment via the spacer, etc., the spacer
material should be electrically conductive(spacer contact surface=6mm
max. dia.).
Terminal No. 5: Output voltage adjustment
Clockwise rotation increases output voltage.
Terminal No. 6: + output terminals(No. 1 to 6 pins of CP51)
Terminal No. 7: – output terminals(No. 1 to 7 pins of CP52)
Terminal No. 8: Spacer mounting hole
3
7
4
4
9 grounding pad
A spacer should be used that is constructed from an insulating
material(spacer contact surface=6mm max. dia.).
Terminal No. 9: VCC terminal(No. 1 pin of CP2)
VCC+
9 grounding pad
8 1-ø3
(
)
soldering surface
clearance
(
)
soldering surface
clearance
(
)
product surface
(
)
product surface
Dimensions in mm
Terminal No. 10: VCC terminals(No. 2 pin of CP2)
VCC–
15±2V should be applied to the VCC terminals if JAH power supplies are
used in parallel. An isolated external DC power supply should be used to
apply this voltage to the VCC terminals.
A123_JAH
980916
Specifications which provide more details for the proper and safe use of the described product are available upon request.
All specifications are subject to change without notice.
©2020 ICPDF网 联系我们和版权申明