JAH05-20R [TDK]

AC-DC Regulated Power Supply Module, 1 Output, 100W, 222 X 75 MM, 35 MM HEIGHT, MODULE;
JAH05-20R
型号: JAH05-20R
厂家: TDK ELECTRONICS    TDK ELECTRONICS
描述:

AC-DC Regulated Power Supply Module, 1 Output, 100W, 222 X 75 MM, 35 MM HEIGHT, MODULE

文件: 总9页 (文件大小:510K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
JAH Series  
Power Supplies  
AC Input  
Single Output, General-Purpose  
FEATURES  
• Low profile, single output AC.200V input power supply.  
• Small open frame.  
• These low noise power supplies are FCC/VDE class  
B standards compliant.  
• Low price.  
PART NUMBERS AND RATINGS  
10W type  
Current(A)  
2
0.84  
0.67  
15W type  
Current(A)  
3
1.3  
1
25W type  
Current(A)  
5
2.1  
1.7  
1.1  
Output voltage(V)  
Part No.  
Part No.  
JAH05-3R0  
JAH12-1R3  
JAH15-1R0  
JAH24-R63  
Part No.  
5
JAH05-2R0  
JAH12-R84  
JAH15-R67  
JAH24-R42  
JAH05-5R0  
JAH12-2R1  
JAH15-1R7  
JAH24-1R1  
12  
15  
24  
0.42  
0.63  
50W type  
Current(A)  
10  
4.2  
3.4  
100W type  
Current(A)  
20  
8.4  
6.7  
4.2  
150W type  
Current(A)  
30  
12.5  
10  
Output voltage(V)  
Part No.  
Part No.  
Part No.  
5
JAH05-10R  
JAH12-4R2  
JAH15-3R4  
JAH24-2R1  
JAH05-20R  
JAH12-8R4  
JAH15-6R7  
JAH24-4R2  
JAH05-30R  
JAH12-13R  
JAH15-10R  
JAH24-6R3  
12  
15  
24  
2.1  
6.3  
Specifications which provide more details for the proper and safe use of the described product are available upon request.  
All specifications are subject to change without notice.  
JAH Series  
Power Supplies  
AC Input  
Single Output, General-Purpose  
SPECIFICATIONS  
10W TYPE  
Part No.  
JAH05-2R0  
5V • 2A  
10  
JAH12-R84  
12V • 0.84A  
10.1  
JAH15-R67  
15V • 0.67A  
10.1  
JAH24-R42  
24V • 0.42A  
10.1  
1
Output voltage, current  
Maximum output power  
Input requirements  
W
2
Input voltage Eac  
Input frequency  
Input current  
V
Hz  
A
170 to 265[Rating:200-240]  
47 to 66[Single phase]  
0.2max.[200V]  
Fuse rating  
A
1.25[Internal]  
Surge current  
A
20max.[200V]  
Leakage current  
Efficiency  
mA  
%
0.75max.[240V, operating]  
71typ.  
73typ.  
73typ.  
73typ.  
Output characteristics  
Output voltage  
Voltage variable range  
Maximum output current  
Overvoltage threshold  
Overcurrent threshold  
V
V
A
V
A
%
%
5
12  
15  
24  
4.5 to 5.5  
2
5.6 to 6.9  
2.1min.  
10.8 to 13.2  
0.84  
13.4 to 15.7  
0.9min.  
13.5 to 16.5  
0.67  
16.7 to 19  
0.7min.  
21.6 to 26.4  
0.42  
26.7 to 30.5  
0.44min.  
1
Input variation  
Load variation  
Temperature  
variation  
2max.(1typ.)[Within the input voltage range]  
2max.(1typ.)[10 to 100% load]  
Total variation ±3max.(±1typ.)  
Voltage stability  
%
2max.(1typ.)[0 to +40°C]  
Drift  
Dynamic load  
%
0.5max.(0.1typ.)[After input voltage ON for 30min to 8h]  
±4max./1max.[50 to 100% sudden load change]  
%/ms  
mV  
ms  
Ripple noise Ep-p  
Start up time  
120max.  
190max.  
220max.  
310max.  
400max.[200V]  
30min.(42typ.)[200V]  
Hold up time  
ms  
Accessory equipment  
Operation indicator  
Overvoltage protection  
Overcurrent protection  
Remote ON-OFF  
Remote sensing  
Output voltage external variable  
function  
None  
Voltage shielding type, recovers upon reset(interval approx. 40s).  
Fixed current and voltage threshold type, automatic recovery, but overcurrent of 1s min. is shielded.  
None  
None  
None  
Standards  
Safety standards  
Noise terminal voltage  
Construction  
EN60950(TÜV) approved.  
VCCI class 2, FCC class B, VDE class B compliant.  
External dimensions H×W×L  
Weight  
mm  
g
21×60×120  
110max.  
Mounting method  
1 side (Open frame)  
1 Current rating(maximum output current) is determined for –10 to +40°C. Derating is required when used outside this temperature range.  
2 Output can stop if input voltage drops below the minimum value continuously for over 1s during supply of power to load.  
Specifications which provide more details for the proper and safe use of the described product are available upon request.  
All specifications are subject to change without notice.  
JAH Series  
Power Supplies  
AC Input  
Single Output, General-Purpose  
SPECIFICATIONS  
15W TYPE  
Part No.  
JAH05-3R0  
5V • 3A  
15  
JAH12-1R3  
12V • 1.3A  
15.6  
JAH15-1R0  
15V • 1A  
15  
JAH24-R63  
24V • 0.63A  
15.1  
1
Output voltage, current  
Maximum output power  
Input requirements  
W
2
Input voltage Eac  
Input frequency  
Input current  
V
Hz  
A
170 to 265[Rating:200-240]  
47 to 66[Single phase]  
0.25max.[200V]  
Fuse rating  
A
1.25[Internal]  
Surge current  
Leakage current  
Efficiency  
A
mA  
%
20max.[200V, 25°C, cold start]  
0.75max.[240V, operating]  
72typ.  
76typ.  
76typ.  
77typ.  
Output characteristics  
Output voltage  
Voltage variable range  
Maximum output current  
Overvoltage threshold  
Overcurrent threshold  
V
V
A
V
A
%
%
5
12  
15  
24  
4.5 to 5.5  
3
5.6 to 6.9  
3.2min.  
10.8 to 13.2  
1.3  
13.4 to 15.7  
1.4min.  
13.5 to 16.5  
1
16.7 to 19  
1.05min.  
21.6 to 26.4  
0.63  
26.7 to 30.5  
0.66min.  
1
Input variation  
Load variation  
Temperature  
variation  
2max.(1typ.)[Within the input voltage range]  
2max.(1typ.)[10 to 100% load]  
Total variation ±3max.(±1typ.)  
Voltage stability  
%
2max.(1typ.)[0 to +40°C]  
Drift  
Dynamic load  
%
0.5max.(0.1typ.)[After input voltage ON for 30min to 8h]  
±4max./1max.[50 to 100% sudden load change]  
%/ms  
mV  
ms  
Ripple noise Ep-p  
Start up time  
120max.  
190max.  
220max.  
310max.  
400max.[200V]  
18min.(25typ.)[200V]  
Hold up time  
ms  
Accessory equipment  
Operation indicator  
Overvoltage protection  
Overcurrent protection  
Remote ON-OFF  
Remote sensing  
Output voltage external variable  
function  
None  
Voltage shielding type, recovers upon reset(interval approx. 40s).  
Fixed current and voltage threshold type, automatic recovery, but overcurrent of 1s min. is shielded.  
None  
None  
None  
Standards  
Safety standards  
Noise terminal voltage  
Construction  
EN60950(TÜV3) approved.  
VCCI class 2, FCC class B, VDE class B compliant.  
External dimensions H×W×L  
Weight  
mm  
g
21×60×120  
110max.  
Mounting method  
1 side (Open frame)  
1 Current rating(maximum output current) is determined for –10 to +40°C. Derating is required when used outside this temperature range.  
2 Output can stop if input voltage drops below the minimum value continuously for over 1s during supply of power to load.  
Specifications which provide more details for the proper and safe use of the described product are available upon request.  
All specifications are subject to change without notice.  
JAH Series  
Power Supplies  
AC Input  
Single Output, General-Purpose  
SPECIFICATIONS  
25W TYPE  
Part No.  
JAH05-5R0  
5V • 5A  
25  
JAH12-2R1  
12V • 2.1A  
25.2  
JAH15-1R7  
15V • 1.7A  
25.5  
JAH24-1R1  
24V • 1.1A  
26.4  
1
Output voltage, current  
Maximum output power  
Input requirements  
W
2
Input voltage Eac  
Input frequency  
Input current  
V
Hz  
A
170 to 265[Rating:200-240]  
47 to 66[Single phase]  
0.35max.[200V ]  
Fuse rating  
A
1.6[Internal ]  
Surge current  
Leakage current  
Efficiency  
A
mA  
%
30max.[200V, 1st surge current]  
0.75max.[240V, operating]  
77typ.  
77typ.  
79typ.  
80typ.  
Output characteristics  
Output voltage  
Voltage variable range  
Maximum output current  
Overvoltage threshold  
Overcurrent threshold  
V
V
A
V
A
%
%
5
12  
15  
24  
4.5 to 5.5  
5
5.6 to 6.9  
5.3min.  
10.8 to 13.2  
2.1  
13.4 to 15.7  
2.2min.  
13.5 to 16.5  
1.7  
16.7 to 19  
1.8min.  
21.6 to 26.4  
1.1  
26.7 to 30.5  
1.2min.  
1
Input variation  
Load variation  
Temperature  
variation  
2max.(1typ.)[Within the input voltage range]  
2max.(1typ.)[10 to 100% load]  
Total variation ±3max.(±1typ.)  
Voltage stability  
%
2max.(1typ.)[0 to +40°C]  
Drift  
Dynamic load  
%
0.5max.(0.1typ.)[After input voltage ON for 30min to 8h]  
±4max./1max.[50 to 100% sudden load change]  
%/ms  
mV  
ms  
Ripple noise Ep-p  
Start up time  
120max.  
190max.  
220max.  
310max.  
500max.[200V]  
27min.(35typ.)[200V]  
Hold up time  
ms  
Accessory equipment  
Operation indicator  
Overvoltage protection  
Overcurrent protection  
Remote ON-OFF  
Remote sensing  
Output voltage external variable  
function  
None  
Voltage shielding type, recovers upon reset(interval approx. 40s).  
Fixed current and voltage threshold type, automatic recovery, but overcurrent of 1s min. is shielded.  
None  
None  
None  
Standards  
Safety standards  
Noise terminal voltage  
Construction  
EN60950(TÜV) approved.  
VCCI class 2, FCC class B, VDE class B compliant.  
External dimensions H×W×L  
Weight  
mm  
g
25×60×143  
160max.  
Mounting method  
1 side (Open frame)  
1 Current rating(maximum output current) is determined for –10 to +40°C. Derating is required when used outside this temperature range.  
2 Output can stop if input voltage drops below the minimum value continuously for over 1s during supply of power to load.  
Specifications which provide more details for the proper and safe use of the described product are available upon request.  
All specifications are subject to change without notice.  
JAH Series  
Power Supplies  
AC Input  
Single Output, General-Purpose  
SPECIFICATIONS  
50W TYPE  
Part No.  
JAH05-10R0  
5V • 10A  
50  
JAH12-4R2  
12V • 4.2A  
50.4  
JAH15-3R4  
15V • 3.4A  
51  
JAH24-2R1  
24V • 2.1A  
50.4  
1
Output voltage, current  
Maximum output power  
Input requirements  
W
2
Input voltage Eac  
Input frequency  
Input current  
V
Hz  
A
170 to 265[Rating:200-240]  
47 to 66[Single phase]  
0.65max.[200V ]  
Fuse rating  
A
2[Internal ]  
Surge current  
Leakage current  
Efficiency  
A
mA  
%
30max.[200V, 25°C, cold start]  
0.75max.[240V, operating]  
80typ.  
80typ.  
82typ.  
83typ.  
Output characteristics  
Output voltage  
Voltage variable range  
Maximum output current  
Overvoltage threshold  
Overcurrent threshold  
V
V
A
V
A
%
%
5
12  
15  
24  
4.5 to 5.5  
10  
5.6 to 6.9  
10.5min.  
10.8 to 13.2  
4.2  
13.4 to 15.7  
4.4min.  
13.5 to 16.5  
3.4  
16.7 to 19  
3.5min.  
21.6 to 26.4  
2.1  
26.7 to 30.5  
2.2min.  
1
Input variation  
Load variation  
Temperature  
variation  
2max.(1typ.)[Within the input voltage range]  
2max.(1typ.)[10 to 100% load]  
Total variation ±3max.(±1typ.)  
Voltage stability  
%
2max.(1typ.)[0 to +40°C]  
Drift  
Dynamic load  
%
0.5max.(0.1typ.)[After input voltage ON for 30min to 8h]  
±4max./1max.[50 to 100% sudden load change]  
%/ms  
mV  
ms  
Ripple noise Ep-p  
Start up time  
120max.  
190max.  
220max.  
310max.  
500max.[200V]  
17min.(25typ.)[200V]  
Hold up time  
ms  
Accessory equipment  
Operation indicator  
Overvoltage protection  
Overcurrent protection  
Remote ON-OFF  
Remote sensing  
Output voltage external variable  
function  
None  
Voltage shielding type, recovers upon reset(interval approx. 40s).  
Fixed current and voltage threshold type, automatic recovery, but overcurrent of 1s min. is shielded.  
None  
None  
None  
Standards  
Safety standards  
Noise terminal voltage  
Construction  
EN60950(TÜV) approved.  
VCCI class 2, FCC class B, VDE class B compliant.  
External dimensions H×W×L  
Weight  
mm  
g
30×60×185  
240max.  
Mounting method  
1 side (Open frame)  
1 Current rating(maximum output current) is determined for –10 to +40°C. Derating is required when used outside this temperature range.  
2 Output can stop if input voltage drops below the minimum value continuously for over 1s during supply of power to load.  
Specifications which provide more details for the proper and safe use of the described product are available upon request.  
All specifications are subject to change without notice.  
JAH Series  
Power Supplies  
AC Input  
Single Output, General-Purpose  
SPECIFICATIONS  
100W TYPE  
Part No.  
JAH05-20R  
5V • 20A  
100  
JAH12-8R4  
12V • 8.4A  
100.8  
JAH15-6R7  
15V • 6.7A  
100.5  
JAH24-4R2  
24V • 4.2A  
100.8  
1
Output voltage, current  
Maximum output power  
Input requirements  
Input voltage Eac  
Input frequency  
Input current  
W
V
Hz  
A
170 to 265[Rating:200-240]  
47 to 66[Single phase]  
1.5max.[200V]  
Fuse rating  
A
3.15[Internal]  
Surge current  
Leakage current  
Efficiency  
A
mA  
%
30max.[200V, 1st surge current, reset after roughly 10s min.]  
0.75max.[240V, operating]  
81typ.  
84typ.  
85typ.  
87typ.  
Output characteristics  
Output voltage  
Voltage variable range  
Maximum output current  
Overvoltage threshold  
Overcurrent threshold  
V
V
A
V
A
%
%
5
12  
15  
24  
4.5 to 5.5  
20  
5.6 to 6.9  
21min.  
10.8 to 13.2  
8.4  
13.4 to 15.7  
8.9min.  
13.5 to 16.5  
6.7  
16.7 to 19  
7.1min.  
21.6 to 26.4  
4.2  
26.7 to 30.5  
4.5min.  
1
Input variation  
Load variation  
Temperature  
variation  
2max.(1typ.)[Within the input voltage range]  
2max.(1typ.)[10 to 100% load]  
Total variation ±3max.(±1typ.)  
Voltage stability  
%
2max.(1typ.)[0 to +40°C]  
Drift  
Dynamic load  
%
0.5max.(0.1typ.)[After input voltage ON for 30min to 8h]  
±4max./1max.[50 to 100% sudden load change]  
%/ms  
mV  
ms  
Ripple noise Ep-p  
Start up time  
120max.  
190max.  
220max.  
310max.  
250max.[200V]  
27min.(35typ.)[200V]  
Hold up time  
ms  
Accessory equipment  
Operation indicator  
Overvoltage protection  
Overcurrent protection  
Remote ON-OFF  
Remote sensing  
None  
Voltage shielding type, recovers upon reset(interval approx. 40s).  
Fixed current and voltage threshold type, automatic recovery, but overcurrent of 1s min. is shielded.  
None  
None  
None  
2
Output voltage external variable function  
Standards  
Safety standards  
EN60950(TÜV) approved.  
Noise terminal voltage  
Construction  
VCCI class 2, FCC class B, VDE class B compliant.  
External dimensions H×W×L  
Weight  
mm  
g
35×75×222  
550max.  
Mounting method  
1 side (Open frame)  
1 Current rating(maximum output current) is determined for –10 to +40°C. Derating is required when used outside this temperature range.  
2 The power supply can be damaged if output current exceeds the rated value, and the overload condition(output current that is greater than the output  
current rating and less than the overcurrent detection threshold) continues for 1min minimum.  
Specifications which provide more details for the proper and safe use of the described product are available upon request.  
All specifications are subject to change without notice.  
JAH Series  
Power Supplies  
AC Input  
Single Output, General-Purpose  
SPECIFICATIONS  
150W TYPE  
Part No.  
JAH05-30R  
5V • 30A  
150  
JAH12-13R  
12V • 12.5A  
150  
JAH15-10R  
15V • 10A  
150  
JAH24-6R3  
24V • 6.3A  
151.2  
1
Output voltage, current  
Maximum output power  
Input requirements  
Input voltage Eac  
Input frequency  
Input current  
W
V
Hz  
A
170 to 265[Rating:200-240]  
47 to 66[Single phase]  
1.95max.[200V]  
Fuse rating  
A
3.15[Internal]  
Surge current  
Leakage current  
Efficiency  
A
mA  
%
30max.[200V, 1st surge current, reset after roughly 10s min.]  
0.75max.[240V, operating]  
82typ.  
83typ.  
84typ.  
86typ.  
Output characteristics  
Output voltage  
Voltage variable range  
Maximum output current  
Overvoltage threshold  
Overcurrent threshold  
V
V
A
V
A
%
%
5
12  
15  
24  
4.5 to 5.5  
30  
5.6 to 6.9  
31.5min.  
10.8 to 13.2  
12.5  
13.4 to 15.7  
13.2min.  
13.5 to 16.5  
10  
16.7 to 19  
10.5min.  
21.6 to 26.4  
6.3  
26.7 to 30.5  
6.7min.  
1
Input variation  
Load variation  
Temperature  
variation  
2max.(1typ.)[Within the input voltage range]  
2max.(1typ.)[10 to 100% load]  
Total variation ±3max.(±1typ.)  
Voltage stability  
%
2max.(1typ.)[0 to +40°C]  
Drift  
Dynamic load  
%
0.5max.(0.1typ.)[After input voltage ON for 30min to 8h]  
±4max./1max.[50 to 100% sudden load change]  
%/ms  
mV  
ms  
Ripple noise Ep-p  
Start up time  
120max.  
190max.  
220max.  
310max.  
250max.[200V]  
30min.(40typ.)[200V]  
Hold up time  
ms  
Accessory equipment  
Operation indicator  
Overvoltage protection  
Overcurrent protection  
Remote ON-OFF  
Remote sensing  
None  
Voltage shielding type, recovers upon reset(interval approx. 40s).  
Fixed current and voltage threshold type, automatic recovery, but overcurrent of 1s min. is shielded.  
None  
None  
2
Output voltage external variable  
function  
None  
Standards  
Safety standards  
Noise terminal voltage  
Construction  
EN60950(TÜV) approved.  
VCCI class 2, FCC class B, VDE class B compliant.  
External dimensions H×W×L  
Weight  
mm  
g
40×85×222  
620max.  
Mounting method  
1 side (Open frame)  
1 Current rating(maximum output current) is determined for –10 to +40°C. Derating is required when used outside this temperature range.  
2
The power supply can be damaged if output current exceeds the rated value, and the overload condition(output current that is greater than the output  
current rating and less than the overcurrent detection threshold) continues for 1min minimum.  
Specifications which provide more details for the proper and safe use of the described product are available upon request.  
All specifications are subject to change without notice.  
JAH Series  
Power Supplies  
AC Input  
Single Output, General-Purpose  
TERMINAL DESIGNATIONS AND FUNCTIONS  
JAH10W  
Terminal No. 1: Input terminal(No. 1 pin of CP1)  
Live line. Fuse is built in.  
9 grounding pad  
soldering surface  
(
)
Terminal No. 2: Input terminal(No. 4 pin of CP1)  
Neutral line  
8 1-ø3  
9 clearance  
clearance  
(
both product and  
soldering surface  
(
)
product surface  
)
Terminal No. 3: Input terminal(No. 8 pin of CP1)  
Ground  
4-ø3.5  
5
Terminal No. 4: Ground  
VR  
1
2
3
Connect with input terminal(No. 8 pin of CP1). If the power supply is  
connected electrically to equipment via the spacer, etc., the spacer  
material should be electrically conductive(spacer contact surface=6mm  
max. dia.).  
6
7
Terminal No. 5: Output voltage adjustment  
Clockwise rotation increases output voltage.  
Terminal No. 6: + output terminal(No. 2 pin of CP51)  
Terminal No. 7: – output terminal(No. 1 pin of CP51)  
Terminal No. 8: Spacer mounting hole  
4
9 grounding pad  
soldering surface  
9 grounding pad  
soldering surface  
(
)
(
)
clearance  
clearance  
A
spacer should be used that is constructed from an insulating  
(
)
(
)
product surface  
product surface  
material(spacer contact surface=6mm max. dia.).  
JAH15W  
Terminal No. 1: Input terminal(No. 1 pin of CP1)  
Live line. Fuse is built in.  
9 grounding pad  
(
)
Terminal No. 2: Input terminal(No. 4 pin of CP1)  
Neutral line  
soldering surface  
8 1-ø3  
9 clearance  
clearance  
(
both product and  
soldering surface  
(
)
product surface  
)
Terminal No. 3: Input terminal(No. 8 pin of CP1)  
Ground  
4-ø3.5  
VR  
1
2
3
Terminal No. 4: Ground  
5
6
7
Connect with input terminal(No. 8 pin of CP1). If the power supply is  
connected electrically to equipment via the spacer, etc., the spacer  
material should be electrically conductive(spacer contact surface=6mm  
max. dia.).  
Terminal No. 5: Output voltage adjustment  
Clockwise rotation increases output voltage.  
Terminal No. 6: + output terminals(No. 3 and 4 pins of CP51)  
Terminal No. 7: – output terminals(No. 1 and 2 pins of CP51)  
Terminal No. 8: Spacer mounting hole  
4
9 grounding pad  
soldering surface  
9 grounding pad  
soldering surface  
(
)
(
)
clearance  
clearance  
(
)
product surface  
(
)
product surface  
A
spacer should be used that is constructed from an insulating  
material(spacer contact surface=6mm max. dia.).  
Terminal No. 1: Input terminal(No. 6 pin of CP1)  
Live line. Fuse is built in.  
JAH25W  
9 clearance  
Terminal No. 2: Input terminal(No. 4 pin of CP1)  
Neutral line  
9 clearance  
(
both product and  
soldering surface  
5
(
both product and  
soldering surface  
)
)
Terminal No. 3: Input terminal(No. 1 pin of CP1)  
Ground  
4-ø3.5  
VR  
1
2
Terminal No. 4: Ground  
Connect with input terminal(No. 1 pin of CP1). If the power supply is  
connected electrically to equipment via the spacer, etc., the spacer  
material should be electrically conductive(spacer contact surface=6mm  
max. dia.).  
3
4
6
7
Terminal No. 5: Output voltage adjustment  
Clockwise rotation increases output voltage.  
Terminal No. 6: + output terminals(No. 1 and 2 pins of CP51)  
Terminal No. 7: – output terminals(No. 3 and 4 pins of CP51)  
Terminal No. 8: Spacer mounting hole  
8 1-ø3  
9 clearance  
9 grounding pad  
soldering surface  
(
)
(
both product and  
soldering surface  
clearance  
)
(
)
product surface  
A
spacer should be used that is constructed from an insulating  
Dimensions in mm  
material(spacer contact surface=6mm max. dia.).  
Specifications which provide more details for the proper and safe use of the described product are available upon request.  
All specifications are subject to change without notice.  
JAH Series  
Power Supplies  
AC Input  
Single Output, General-Purpose  
TERMINAL DESIGNATIONS AND FUNCTIONS  
JAH50W  
Terminal No. 1: Input terminal(No. 6 pin of CP1)  
Live line. Fuse is built in.  
Terminal No. 2: Input terminal(No. 4 pin of CP1)  
Neutral line  
9 clearance  
8 1-ø3  
9 clearance  
(
both product and  
(
both product and  
soldering surface  
)
soldering surface  
)
Terminal No. 3: Input terminal(No. 1 pin of CP1)  
Ground  
Terminal No. 4: Ground  
Connect with input terminal(No. 1 pin of CP1). If the power supply is  
connected electrically to equipment via the spacer, etc., the spacer  
material should be electrically conductive(spacer contact surface=6mm  
max. dia.).  
4-ø3.5  
1
2
3
6
7
Terminal No. 5: Output voltage adjustment  
Clockwise rotation increases output voltage.  
Terminal No. 6: + output terminals(No. 1 and 2 pins of CP51)  
Terminal No. 7: – output terminals(No. 3 and 4 pins of CP51)  
Terminal No. 8: Spacer mounting hole  
4
4
9 grounding pad  
9 grounding pad  
(
)
soldering surface  
clearance  
5
(
)
soldering surface  
clearance  
(
)
product surface  
(
)
product surface  
A
spacer should be used that is constructed from an insulating  
material(spacer contact surface=6mm max. dia.).  
Terminal No. 1: Input terminal(No. 6 pin of CP1)  
Live line. Fuse is built in.  
Terminal No. 2: Input terminal(No. 4 pin of CP1)  
Neutral line  
Terminal No. 3: Input terminal(No. 1 pin of CP1)  
Ground  
Terminal No. 4: Ground  
JAH100W  
9 grounding pad  
soldering surface  
9 grounding pad  
soldering surface  
(
)
(
)
8 1-ø3  
clearance  
clearance  
5
(
)
product surface  
(
)
product surface  
1
2
4-ø3.5  
6
Connect with input terminal(No. 1 pin of CP1). If the power supply is  
connected electrically to equipment via the spacer, etc., the spacer  
material should be electrically conductive(spacer contact surface=6mm  
max. dia.).  
3
7
Terminal No. 5: Output voltage adjustment  
Clockwise rotation increases output voltage.  
Terminal No. 6: + output terminals(No. 1 to 4 pins of CP51)  
Terminal No. 7: – output terminals(No. 5 to 8 pins of CP51)  
Terminal No. 8: Spacer mounting hole  
4
9 grounding pad  
soldering surface  
9 grounding pad  
soldering surface  
(
)
(
)
A spacer should be used that is constructed from an insulating  
material(spacer contact surface=6mm max. dia.).  
clearance  
clearance  
(
)
(
)
product surface  
product surface  
JAH150W  
Terminal No. 1: Input terminal(No. 6 pin of CP1)  
Live line. Fuse is built in.  
Terminal No. 2: Input terminal(No. 4 pin of CP1)  
Neutral line  
Terminal No. 3: Input terminal(No. 1 pin of CP1)  
Ground  
Terminal No. 4: Ground  
9 clearance  
9 clearance  
4-ø3.5  
(
(
both product and  
)
soldering surface  
both product and  
soldering surface  
9 10  
)
4
5
6
1
2
Connect with input terminal(No. 1 pin of CP1). If the power supply is  
connected electrically to equipment via the spacer, etc., the spacer  
material should be electrically conductive(spacer contact surface=6mm  
max. dia.).  
Terminal No. 5: Output voltage adjustment  
Clockwise rotation increases output voltage.  
Terminal No. 6: + output terminals(No. 1 to 6 pins of CP51)  
Terminal No. 7: – output terminals(No. 1 to 7 pins of CP52)  
Terminal No. 8: Spacer mounting hole  
3
7
4
4
9 grounding pad  
A spacer should be used that is constructed from an insulating  
material(spacer contact surface=6mm max. dia.).  
Terminal No. 9: VCC terminal(No. 1 pin of CP2)  
VCC+  
9 grounding pad  
8 1-ø3  
(
)
soldering surface  
clearance  
(
)
soldering surface  
clearance  
(
)
product surface  
(
)
product surface  
Dimensions in mm  
Terminal No. 10: VCC terminals(No. 2 pin of CP2)  
VCC–  
15±2V should be applied to the VCC terminals if JAH power supplies are  
used in parallel. An isolated external DC power supply should be used to  
apply this voltage to the VCC terminals.  
A123_JAH  
980916  
Specifications which provide more details for the proper and safe use of the described product are available upon request.  
All specifications are subject to change without notice.  

相关型号:

JAH05-2R0

AC-DC Regulated Power Supply Module, 1 Output, 10W, 120 X 60 MM, 21 MM HEIGHT
TDK

JAH05-30R

AC-DC Regulated Power Supply Module, 1 Output, 150W, 222 X 85 MM, 40 MM HEIGHT
TDK

JAH05-5R0

AC-DC Regulated Power Supply Module, 1 Output, 25W, 143 X 60 MM, 25 MM HEIGHT
TDK

JAH12-13R

AC-DC Regulated Power Supply Module, 1 Output, 150W, 222 X 85 MM, 40 MM HEIGHT
TDK

JAH12-1R3

AC-DC Regulated Power Supply Module, 1 Output, 15.6W, 120 X 60 MM, 21 MM HEIGHT
TDK

JAH12-8R4

AC-DC Regulated Power Supply Module, 1 Output, 100.8W, 222 X 75 MM, 35 MM HEIGHT, MODULE
TDK

JAH24-1R1

AC-DC Regulated Power Supply Module, 1 Output, 26.4W, 143 X 60 MM, 25 MM HEIGHT
TDK

JAH24-2R1

AC-DC Regulated Power Supply Module, 1 Output, 50.4W, 185 X 60 MM, 30 MM HEIGHT
TDK

JAH24-4R2

AC-DC Regulated Power Supply Module, 1 Output, 100.8W, 222 X 75 MM, 35 MM HEIGHT, MODULE
TDK

JAH24-6R3

AC-DC Regulated Power Supply Module, 1 Output, 151.2W, 222 X 85 MM, 40 MM HEIGHT
TDK

JAH24-R42

AC-DC Regulated Power Supply Module, 1 Output, 10.1W, 120 X 60 MM, 21 MM HEIGHT
TDK

JAH24-R63

AC-DC Regulated Power Supply Module, 1 Output, 15.1W, 120 X 60 MM, 21 MM HEIGHT
TDK