MRW-151 [TDK]
AC-DC Regulated Power Supply Module, 3 Output, 35W, 160 X 100 MM, 30 MM HEIGHT, MODULE;型号: | MRW-151 |
厂家: | TDK ELECTRONICS |
描述: | AC-DC Regulated Power Supply Module, 3 Output, 35W, 160 X 100 MM, 30 MM HEIGHT, MODULE |
文件: | 总19页 (文件大小:309K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
A111_MRW
(1/19)
TDK Switching Power Supply
Wide-input 2- and 3-output type bestseller power supply
M SERIES MRW
UL/CSA/TÜV approved
[FEATURES]
• Wide-input (AC.100V/200V switching not required) thin-type
multi-output power supply.
• Open frame type.
• POK signal function (MRW-150/-151/-160/-161).
• Low noise (FCC class B).
[SUMMARY]
The M series MRW products are open-frame multi-output power
supplies characterized by the wide input range and thin type. They
are available at low prices and Safety standards certified with full
EMC countermeasures. It is recommended to use them as
economical export power supplies. In addition to the conventional
products, the 170 series and 350 series are supported newly.
PART NUMBERS AND RATINGS
Maximum output Output1[V1]
Output2[V2]
Output3[V3]
Part No.
power (W)
Voltage(V)
Current(A)
Voltage(V)
+12
Current(A)
Voltage(V)
Current(A)
MRW-135
MRW-150
MRW-151
MRW-160
MRW-161
MRW-170
MRW-171
MRW-350
28
35
35
50
50
65
65
40
+5
+5
+5
+5
+5
+5
+5
+5
0.5 to 2
0.3 to 1.5(2.5, 3s)
0.6 to 1.8(Max.2.5)
0.5 to 1.4(Max.2)
0.6 to 2(Max.2.5)
0.5 to 1.5(Max.2)
0.3 to 1.7(Max.2.5)
0.3 to 1.3(Max.2)
0.3 to 2
1 to 2.2(Max.4)
1 to 2.2(Max.4)
1 to 5(Max.6)
1 to 5(Max.6)
0.8 to 5(Max.7)
0.8 to 5(Max.7)
0.5 to 3
+12
–12
–15
–12
–15
–12
–15.8
–12
0 to 0.1(Max.0.3)
0 to 0.1(Max.0.25)
0 to 0.1(Max.0.5)
0 to 0.1(Max.0.4)
0.3 to 1.7(Max.2.5)
0.3 to 1.3(Max.2)
0 to 0.1
+15
+12
+15
+12
+15.8
+12
The total sum of the output voltage multiplied by the output current cannot exceed the maximum output power.
For the details, please refer to the next pages.
•
:Stock products.
All specifications are subject to change without notice.
A111_MRW
(2/19)
TDK Switching Power Supply
M SERIES MRW-135
UL/CSA/TÜV approved
SPECIFICATIONS AND STANDARDS
PART NO.
MRW-135
Rated output voltage
and current 1
V1
V2
W
+5V • 2A
+12V • 1.5A(Peak 2.5A, 3s max.) 4
Maximum output power
INPUT CONDITIONS
Input voltage Eac
Input frequency
Input current
28
V
90 to 264[Rating: 100 to 120/200 to 240]
47 to 66[Rating: 50 to 60](Single phase)
0.8max./0.5max.[AC.100 to 120/200 to 240V]
2[Built-in]
Hz
A
Fuse rating
A
Surge current
A
50max./100max.[AC.100 to 120/200 to 240V, 25°C, cold start]
0.5max./0.75max.[AC.100 to 120/200 to 240V]
73typ.[AC.100 to 120V]
Leakage current
Efficiency
mA
%
OUTPUT CHARACTERISTICS
Output voltage Edc
V
+5(V1)
+5, –3
2
+12(V2)
Voltage variable range
Maximum output current
Minimum output current 3
Output setting [Voltage]
%
A
V2 varies simultaneously and in the same direction as V1.
1.5(Peak 2.5A, 3s) 4
A
0.5
0.3
V
5±0.02
2
—
conditions
[Current]
A
1.5
Input variation
Load variation 2
%
%
1max.
2max.
1.5max.[AC.90 to 132V/180 to 264V]
3max.
Temperature variation
[0 to +50°C]
%
2max.
3max.
Voltage
stability
Total variation
Drift
%
+4, –3max.
±5max.
%
0.5max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]
±4max./1max.[50 to 100% sudden load change]
Dynamic load
%/ms
mV
mV
ms
ms
Ripple Ep-p
80max.
150max.
750typ.
120max.
290max.
Ripple noise Ep-p
Start up time
Hold up time
10min.(15typ.)[AC.100V input], 20min.(25typ.)[AC.120V input]
AUXILIARY FUNCTIONS
Indicator display
Overvoltage protection
Overcurrent protection
Remote ON-OFF
Remote sensing
Current balance
No
Only 5V built-in protection, voltage shut-down type(overvoltage threshold 5.8 to 6.9V), recovers upon reset.
41W min., total power type
No
No
No
Output voltage external variable function No
STANDARDS
Safety standards
Noise terminal voltage
CONSTRUCTIONS
External dimensions
Weight
UL1950-3, CSA950-95(C-UL), EN60950(TÜV) approved.
FCC class B, VDE0871 class B compliant.
mm
g
35×80×120[H×W×L]
300max.
Mounting method
Case and cover
Can be attached to 1 side.
—
Input and output cables
Sold separately(Part No.: 4EU20B241)
1 Current rating(maximum output current) is determined for 0 to +50°C. Derating is required when used outside this temperature range.
2 Load variation only for an output to be measured with other outputs fixed to V1 at 1.5A and V2 at 1.5A.
3 The output voltages V1 and V2 may not output regular voltages at the minimum output current or lower.
4 If +12V load current exceeds 1.5A, the time should be limited to 3 sec or shorter with the effective current maintained at 1.5A or lower for use.
All specifications are subject to change without notice.
A111_MRW
(3/19)
TDK Switching Power Supply
M SERIES MRW-135
UL/CSA/TÜV approved
Dimensions in mm
SHAPES AND DIMENSIONS
MRW-135
±1mm : without specified dimensions
120
4
112±0.7
31max.
1.6±0.2
Primary
Secondary
P1
P2
P3
P4
P5
P6
P7
P8
P1
P2
P3
P4
L
CP52
CP51
CP2
CP1
N
(9)
3max.
4-ø3.5
[Terminal place]
FG: CP1
Output
CP51
+12V
CP52
Input: CP2
P1
P2
P3
P4
P5
P6
P7
P8
COMMON
+5V
L
LIVE
COMMON
N
NEUTRAL
+5V
COMMON
—
—
—
—
COMMON
+12V
• Use M3.5 installation screw holes and solder-land must not over than 9mm from edge of printed circuit board. Components surface must keep
less than 6.5mm diameter from the hole center.
(When use metal cover or other metal installation parts, please keep more than 4mm from primary components and any lead wires for safety.)
All specifications are subject to change without notice.
A111_MRW
(4/19)
TDK Switching Power Supply
M SERIES MRW-150/151
UL/CSA/TÜV approved
SPECIFICATIONS AND STANDARDS
PART NO.
MRW-150
MRW-151
V1
V2
V3
W
+5V • 2.2A(4A) 4
+12V • 1.8A(2.5A) 4
–12V • 0.1A(0.3A) 4
35
+5V • 2.2A(4A) 4
+15V • 1.4A(2A) 4
–15V • 0.1A(0.25A) 4
35
Rated output voltage
and current 1
Maximum output power
INPUT CONDITIONS
Input voltage Eac
Input frequency
Input current
V
90 to 264[Rating: 100, 120, 200, 240]
47 to 66[Rating: 50 to 60](Single phase)
Hz
A
1max./0.5max.[AC.100/200V, maximum output rated power]
2.5[Built-in]
Fuse rating
A
Surge current
A
50max./100max.[AC.100/200V, 25°C, cold start]
0.5max./0.75max.[AC.100/200V, 25°C, output rating]
Leakage current
Efficiency
mA
%
70typ.
70typ.
OUTPUT CHARACTERISTICS
Output voltage Edc
V
+5(V1)
+5, –3
+12(V2)
–12(V3)
+5(V1)
+5, –3
+15(V2)
–15(V3)
V2 varies simultaneously and
in the same direction as V1.
V2 varies simultaneously and
in the same direction as V1.
Voltage variable range
%
Maximum output current 1
Rated output current
Minimum output current 2
A
A
A
V
A
V
%
%
4
2.5
1.8
0.6
—
0.3
0.1
0
4
2
0.25
0.1
0
2.2
2.2
1.4
0.5
—
1
1
Output setting [Voltage]
5±0.02
2.2
—
5±0.02
2.2
—
conditions
[Current]
1.8
0.1
1.4
0.1
Overvoltage threshold
5.8 to 6.9
1typ.
3typ
5.8 to 6.9
1typ.
3typ.
Input variation
Load variation 3
1typ.
5typ.
1typ.
1typ.
1typ.
5typ.
1typ.
1typ.
Temperature variation
[0 to +50°C]
Voltage
stability
%
2typ.
2typ.
1typ.
2typ.
2typ.
2typ.
Total variation
Drift
%
+4, –2max.
±5max.
±6max.
+4, –2max.
+3, –8max.
±6max.
%
0.5max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]
±4max./2max.[50 to 100% sudden load change]
Dynamic load
%/ms
mV
mV
ms
ms
ms
Ripple Ep-p
50max.
80max.
30max.
80max.
120max.
350max.
30max.
Ripple noise Ep-p
Start up time
150max.
290max.
290max.
150max.
350max.
600max.[25°C, input and output ratings]
20max.[25°C, input and output ratings]
15min.[25°C, input and output ratings]
530max.[25°C, input and output ratings]
10max.[25°C, input and output ratings]
15min.[25°C, input and output ratings]
Rise time
Hold up time
AUXILIARY FUNCTIONS
Indicator display
Overvoltage protection
Overcurrent protection
Remote ON-OFF
Remote sensing
STANDARDS
No
Only 5V built-in protection, voltage shut-down type, recovers upon reset (interval approx. 45s).
36W min., total power type
No
No
Safety standards
Noise terminal voltage
CONSTRUCTIONS
External dimensions
Weight
UL1950-3, CSA950-95(C-UL), EN60950(TÜV) approved.
FCC class B, VDE0871 class B compliant.
mm
g
30×100×160[H×W×L]
350max.
Mounting method
Case and cover
Input and output cables
1 side(Open frame)
Frame/cover sold separately (Part No.: 2JF00B157/2JC0ZB156)
Sold separately(Part No.: 4EU40B153)
1 Current rating(maximum output current) is determined for 0 to +50°C. Derating is required when used outside this temperature range.
2 Normal output voltages might possibly not be maintained if outputs V2, V3 fall below V1 minimum current values.
3 Load range
V1: 1 to 2.2A, V2: 0.6 to 1.8A, V3: 0 to 0.1A
4 At the maximum output current value within the parentheses, the sum of all output(V1,V2 and V3) power values can not exceed this maximum output
power.
All specifications are subject to change without notice.
A111_MRW
(5/19)
TDK Switching Power Supply
M SERIES MRW-150/151
UL/CSA/TÜV approved
Dimensions in mm
SHAPES AND DIMENSIONS
MRW-150/151
±1mm : without specified dimensions
ø14 Clearance(soldering side)
ø14 Clearance(soldering side)
160
26max.
121.9±0.7
2max.
P2
P1
CP54
P4
P3
P2
P1
P4
P3
P2
P1
P4
P3
P2
P1
CP53
CP52
CP51
4-ø4
CP1
N
L
CP2
5max.
14G Pad(soldering side)
14 Clearance(soldering side)
FG terminal
30max.
[Terminal place]
CP1: AC INPUT
CP51, CP52, CP53: OUTPUT
CP54: POWER OK SIGNAL
L
LIVE
MRW-150
+5V
MRW-151
+5V
P1
P2
COMMON
N
NEUTRAL
P1
P2
P3
P4
POWER OK SIGNAL
CP2: FG
COMMON
+12V
COMMON
+15V
–12V
–15V
All specifications are subject to change without notice.
A111_MRW
(6/19)
TDK Switching Power Supply
M SERIES MRW-160/161
UL/CSA/TÜV approved
SPECIFICATIONS AND STANDARDS
PART NO.
MRW-160
MRW-161
V1
V2
V3
W
+5V • 5A(6A) 3
+12V • 2A(2.5A) 3
–12V • 0.1A(0.5A) 3
50
+5V • 5A(6A) 3
+15V • 1.5A(2A) 3
–15V • 0.1A(0.4A) 3
50
Rated output voltage
and current*1
Maximum output power
INPUT CONDITIONS
Input voltage Eac
Input frequency
Input current
V
90 to 264[Rating: 100 to 120/200 to 240]
47 to 66[Rating: 50 to 60](Single phase)
1.3max./0.8max.[AC.100 to 120/200 to 240V]
3[Built-in]
Hz
A
Fuse rating
A
Surge current
A
50max./100max.[AC.100 to 120/200 to 240V, 25°C, cold start]
0.5max./0.75max.[AC.100 to 120/200 to 240V]
Leakage current
Efficiency
mA
%
75typ.
73typ.
OUTPUT CHARACTERISTICS
Output voltage Edc
V
+5(V1)
+5, –3
+12(V2)
–12(V3)
+5(V1)
+5, –3
+15(V2)
–15(V3)
V2 varies simultaneously and
in the same direction as V1.
V2 varies simultaneously and
in the same direction as V1.
Voltage variable range
%
Maximum output current 1
Rated output current
Minimum output current 2
A
A
A
V
A
%
%
6
2.5
2
0.5
6
2
0.4
5
0.1
5
1.5
0.1
1
0.6
—
0
1
0.5
0
Output setting [Voltage]
5±0.02
2.5
—
5±0.02
2.5
—
—
conditions
[Current]
2
0.1
1.5
0.1
Input variation
Load variation 2
2max.
4max.
2max.
2max.
1max.
1max.
2max.
4max.
2max.
2max.
1max.
1max.
Temperature variation
[0 to +50°C]
%
2max.
2max.
1max.
2max.
2max.
1max.
Voltage
stability
Total variation
Drift
%
±4max.
+6, –4max.
±6max.
±4max.
+8, –2max.
±6max.
%
0.5max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]
±4max./1max.[50 to 100% sudden load change]
Dynamic load
%/ms
mV
mV
ms
ms
Ripple Ep-p
80max.
80max.
30max.
80max.
80max.
30max.
Ripple noise Ep-p
Start up time
150max.
500typ.
290max.
290max.
150max.
350max.
350max.
Hold up time
20min.(30typ.)
AUXILIARY FUNCTIONS
Indicator display
Overvoltage protection
Overcurrent protection
Remote ON-OFF
Remote sensing
Current balance
No
Only 5V built-in protection, voltage shut-down type(overvoltage threshold 5.8 to 6.9V), recovers upon reset.
60W min., total power type
No
No
No
Output voltage external variable function No
STANDARDS
Safety standards
Noise terminal voltage
CONSTRUCTIONS
External dimensions
Weight
UL1950-3, CSA950-95(C-UL), EN60950(TÜV) approved.
FCC class B, VDE0871 class B compliant.
mm
g
38×100×160[H×W×L]
500max.
Mounting method
Case and cover
Can be attached to 1 side.
Frame/cover sold separately (Part No.: 2JF00B167/2JC0ZB166)
Input and output cables
Sold separately(Part No.: 4EU40B153)
1 Current rating(maximum output current) is determined for 0 to +50°C. Derating is required when used outside this temperature range.
2 Normal output voltages might possibly not be maintained if outputs V2, V3 fall below V1 minimum current values.
3 At the maximum output current value within the parentheses, the sum of all output(V1,V2 and V3) power values can not exceed this maximum output
power.
All specifications are subject to change without notice.
A111_MRW
(7/19)
TDK Switching Power Supply
M SERIES MRW-160/161
UL/CSA/TÜV approved
Dimensions in mm
SHAPES AND DIMENSIONS
MRW-160/161
±1mm : without specified dimensions
ø14 Clearance(soldering side)
ø14 Clearance(soldering side)
160
33max.
121.9±0.7
P2
P1
CP54
P4
P3
P2
P1
CP53
P4
P3
P2
P1
CP52
CP51
P4
P3
P2
P1
4-ø4
CP1
N
L
CP2
5max.
14G Pad(soldering side)
FG terminal
38max.
14 Clearance(soldering side)
[Terminal place]
CP1: AC INPUT
CP51, CP52, CP53: OUTPUT
CP54: POWER OK SIGNAL
P1 COMMON
L
LIVE
MRW-160
+5V
MRW-161
+5V
N
NEUTRAL
P1
P2
P3
P4
P2 POWER OK SIGNAL
CP2: FG
COMMON
+12V
COMMON
+15V
–12V
–15V
All specifications are subject to change without notice.
A111_MRW
(8/19)
TDK Switching Power Supply
M SERIES MRW-170/171
UL/CSA/TÜV approved
SPECIFICATIONS AND STANDARDS
PART NO.
MRW-170
MRW-171
V1
V2
V3
W
+5V • 5A(7A) 4
+12V • 1.7A(2.5A) 4
–12V • 1.7A(2.5A) 4
65
+5V • 5A(7A) 4
+15.8V • 1.3A(2A) 4
–15.8V • 1.3A(2A) 4
65
Rated output voltage
and current*1
Maximum output power
INPUT CONDITIONS
Input voltage Eac
Input frequency
Input current
V
85 to 264[Rating: 100/240]
Hz
A
47 to 66[Rating: 50 to 60](Single phase)
1.7max./0.9max.[AC.100/240V]
3.15[Built-in]
Fuse rating
A
Surge current
A
50max./100max.[AC.115/230V, 25°C, cold start]
0.5max./0.75max.[AC.115/230V, 25°C, output rating]
70typ.
Leakage current
Efficiency
mA
%
70typ.
+5(V1)
OUTPUT CHARACTERISTICS
Output voltage Edc
V
V
A
A
A
V
A
V
%
%
+5(V1)
—
+12(V2)
–12(V3)
+15.8(V2)
–15.8(V3)
Voltage variable range
Maximum output current 1
Rated output current
7
2.5
1.7
0.3
—
2.5
1.7
0.3
—
7
2
2
5
5
1.3
0.3
—
1.3
0.3
—
Minimum output current 2
0.8
0.8
Output setting [Voltage]
5±0.02
5
5±0.02
5
conditions
[Current]
1.7
1.7
1.3
1.3
Overvoltage threshold
5.8 to 6.9
1typ.
3.5typ.
5.8 to 6.9
1typ.
3.5typ.
Input variation
1typ.
5typ.
1typ.
5typ.
1typ.
5typ.
1typ.
5typ.
Load variation 3
Temperature variation
[0 to +50°C]
%
2typ.
3.5typ.
3.5typ.
2typ.
3.5typ.
3.5typ.
Voltage
stability
Total variation
Drift
%
±4max.
+8, –7max.
+8, –7max.
±4max.
+8, –7max.
+8, –7max.
%
0.5max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]
±4max./0.5max.[50 to 100% sudden load change]
Dynamic load
%/ms
mV
mV
mV
ms
ms
Ripple
Ep-p
Source
30max.
30max.
50max.
250max.
30max.
50max.
250max.
30max.
50max.
150max.
30max.
50max.
250max.
30max.
50max.
250max.
Switching
50max.
Ripple noise Ep-p
Start up time
150max.
600typ.[AC.115V]
Hold up time
15min.(20typ.)[AC.115V]
AUXILIARY FUNCTIONS
Indicator display
Overvoltage protection
Overcurrent protection
Remote ON-OFF
Remote sensing
STANDARDS
No
Only 5V built-in protection, voltage shut-down type, recovers upon reset.
66W min., total power type
No
No
Safety standards
Noise terminal voltage
CONSTRUCTIONS
External dimensions
Weight
UL1950-3, CSA950-95(C-UL), EN60950(TÜV) approved.
FCC class B, VDE0871 class B compliant.
mm
g
38×100×160[H×W×L]
450max.
Mounting method
Case and cover
1 side(Open frame)
—
Input and output cables
—
1 Current rating(maximum output current) is determined for 0 to +50°C. Derating is required when used outside this temperature range.
2 Normal output voltages might possibly not be maintained if outputs V2, V3 fall below V1 minimum current values.
3 The load variation is determined within a range of the minimum output current to the rated output current.
4 The value in parentheses indicates the maximum output current. The total output power of V1 to V3 cannot exceed the maximum output power.
All specifications are subject to change without notice.
A111_MRW
(9/19)
TDK Switching Power Supply
M SERIES MRW-170/171
UL/CSA/TÜV approved
Dimensions in mm
SHAPES AND DIMENSIONS
MRW-170/171
±1mm : without specified dimensions
ø14 Clearance
(soldering side)
10×10G Pad
(soldering side)
160
33max.
5max.
121.9±0.7
ø3.2
ø4.0
P57
P56
P55
P54
P53
P52
P51
CP51
N
CP1
CP2
L
FG terminal
ø3.2
ø4.0
ø14 Clearance
(soldering side)
10×10G Pad
(soldering side)
[Terminal place]
CP2: AC INPUT
CP51: OUTPUT
L
LIVE
P57
P56
P55
P54
P53
P52
P51
+12V
P57
+15V
+5V
N
NEUTRAL
+5V
P56
P55
P54
P53
P52
P51
CP1: FG
+5V
+5V
COMMON
COMMON
COMMON
–12V
COMMON
COMMON
COMMON
–15V
(MRW-170)
(MRW-171)
All specifications are subject to change without notice.
A111_MRW
(10/19)
TDK Switching Power Supply
M SERIES MRW-350
UL/CSA/TÜV approved
SPECIFICATIONS AND STANDARDS
PART NO.
MRW-350
+5V • 3A
+12V • 2A
–12V • 0.1A
40
V1
V2
V3
W
Rated output voltage
and current*1
Maximum output power
INPUT CONDITIONS
Input voltage Eac
Input frequency
Input current
V
90 to 264[Rating: 100/120/220/240]
47 to 66[Rating: 50 to 60Hz](Single phase)
0.9max./0.55max.[AC.100/240V]
2[Built-in]
Hz
A
Fuse rating
A
Surge current
A
50max./100max.[AC.115/230V, 25°C, cold start]
0.5max./0.75max.[AC.115/230V, 25°C, output rating]
70typ.
Leakage current
Efficiency
mA
%
OUTPUT CHARACTERISTICS
Output voltage Edc
V
V
A
A
V
A
V
%
%
+5(V1)
—
+12(V2)
–12(V3)
Voltage variable range
Maximum output current 1
Minimum output current 2
Output setting [Voltage]
3
2
0.1
0
0.5
0.3
—
5±0.02
3
—
conditions
[Current]
2
0
Overvoltage threshold
5.8 to 6.9
1typ.
2typ.
—
—
Input variation
Load variation 3
1typ.
4typ.
1typ.
1typ.
Temperature variation
[0 to +50°C]
%
2typ.
3.5typ.
1typ.
Voltage
stability
Total variation
%
±3.5max.
±7max.
±7max.
Drift
%
0.5max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]
±4max./0.5typ.[50 to 100% sudden load change]
Dynamic load
%/ms
mV
mV
mV
ms
ms
Ripple
Ep-p
Source
30max.
100max.
20max.
10max.
20max.
Switching
25max.
Ripple noise Ep-p
Start up time
150max.
250max.
250max.
500typ.[AC.120V]
15min.(20typ.)[AC.120V]
Hold up time
AUXILIARY FUNCTIONS
Indicator display
Overvoltage protection
Overcurrent protection
Remote ON-OFF
Remote sensing
STANDARDS
No
Only 5V built-in protection, voltage shut-down type, recovers upon reset.
41W min., total power type
No
No
Safety standards
Noise terminal voltage
CONSTRUCTIONS
External dimensions
Weight
UL1950-3, CSA950-95(C-UL), EN60950(TÜV) approved.
FCC class B, VDE0871 class B compliant.
mm
g
36.75×76×127[H×W×L]
240max.
Mounting method
Case and cover
1 side(Open frame)
—
Input and output cables
—
1 Current rating(maximum output current) is determined for 0 to +50°C. Derating is required when used outside this temperature range.
2 Normal output voltages might possibly not be maintained if outputs V2, V3 fall below V1 minimum current values.
3 Load variation will be specified from the minimum output current to the rated output current range.
All specifications are subject to change without notice.
A111_MRW
(11/19)
TDK Switching Power Supply
M SERIES MRW-350
UL/CSA/TÜV approved
Dimensions in mm
SHAPES AND DIMENSIONS
MRW-350
±1mm : without specified dimensions
ø7.5 Clearance
(soldering side)
(5)
127
9×9G Pad
117±0.7
31.75max.
5max.
(soldering side)
ø3.2
ø3.5
CP51
P3
CP2
CP56
CP55
CP54
CP53
CP52
CP51
P2
P1
CP1
ø3.5
ø3.2
FG terminal
10×9G Pad
(soldering side)
9×9 Clearance
(soldering side)
[Terminal place]
CP1
CP2: AC INPUT
CP51: DC OUTPUT
P1
FG
P2
P3
L(LIVE)
P56 +12V
N(NEUTRAL)
P55 +5V
P54 +5V
P53 COMMON
P52 COMMON
P51 –12V
All specifications are subject to change without notice.
A111_MRW
(12/19)
TDK Switching Power Supply
Characteristics, Functions, and Applications
BLOCK DIAGRAM
MRW-135/150/151/160/161
FG
Surge
Input
L
Output rectifying
and smoothing
circuit
Input rectifying
and
smoothing circuit
Three-terminal
regulator
current
limiting
circuit
AC input
filter
1
N
V3
V2
circuit
Over-
Power
switching
circuit
Output rectifying
and smoothing
circuit
current
detection
circuit
DC output
Output rectifying
and smoothing
circuit
Drive
circuit
V1
COM
POWER OK
signal output 2
COM
Output voltage
detection
circuit
Control circuit
Control circuit
Overvoltage
detection
circuit
1 Except the broken line portion for MRW-135.
MRW-135 has not POWER OK signal output terminal.
2
MRW-170/171
FG
Surge
current
limiting
circuit
Input
filter
circuit
Output rectifying
and smoothing
circuit
Input rectifying
and
smoothing circuit
L
AC input
N
1
V3
V2
Over-
Power
switching
circuit
Output rectifying
and smoothing
circuit
current
detection
circuit
DC output
Output rectifying
and smoothing
circuit
Drive
circuit
V1
COM
Control circuit
Control circuit
Overvoltage
detection
circuit
All specifications are subject to change without notice.
A111_MRW
(13/19)
TDK Switching Power Supply
Characteristics, Functions, and Applications
MRW-350
FG
Surge
current
limiting
circuit
Input
filter
circuit
Input rectifying
and
smoothing circuit
Output rectifying
and smoothing
circuit
L
AC input
N
Three-terminal
regulator
V3
Over-
Power
switching
circuit
V2
current
detection
circuit
DC output
Output rectifying
and smoothing
circuit
Drive
circuit
V1
COM
Control circuit
Control circuit
Overvoltage
detection
circuit
TERMINAL DESIGNATIONS AND FUNCTIONS
MRW-135
MRW-150, 151, 160, 161
Pin location
Pin location
2 MRW135
P2
P1
4 MRW150, 160, 161
CP54
CP1
1
2
1
Input(L)
Input(N)
FG
CP1
CP2
1
2
1
FG
P1
P2
P3
P4
P5
P6
P7
P8
Input(L)
Input(N)
CP2
CP51 P1 V1
P2 COMMON
CP51 P1 V2
P2 COMMON
P4
P3
P2
P1
CP52
CP51
CP53
P3 V2
P4 V3
P3 V1
P4 COMMON
CP52 P1 COMMON
P2 COMMON
P3 V1
CP52 P1 V1
P4
P3
P2
P1
P2 COMMON
CP52
CP51
P3 V2
P4 V3
P4 V1
P1
P2
P3
P4
P4
P3
P2
P1
CP53 P1 V1
P5 COMMON
P6 COMMON
P7 V2
P2 COMMON
P3 V2
P4 V3
P8 V2
CP54 P1 COMMON
CP1
L
N
L
P2 POWER OK SIGNAL
CP2
CP1
N
CP2
FG terminal
1
2
3
AC input terminals(L, N)
4
5
DC output common terminal(COMMON)
Connect to AC.100/120V or AC.200/240V single phase input line.
Connect to load.
Frame ground terminal(G)
POWER OK signal output terminal (POWER OK SIGNAL)
Outputs the signal at 4.5V min. of the +5V output voltage
(Applied to MRW-150, 151, 160, and 161).
Connect to earth ground. This is connected to the case.
DC output terminals(V1, V2, V3)
Connect to load.
All specifications are subject to change without notice.
A111_MRW
(14/19)
TDK Switching Power Supply
Characteristics, Functions, and Applications
MRW-170, 171
MRW-350
P4
FG
P58
Pin location
Pin location
2 MRW350
P57
P56
P55
P54
P53
2 MRW170, 171
P3
P2
CP1
CP2
P1 FG(Primary)
CP1
CP2
P1 FG(Primary)
P2 Input(L)
P56
P55
P54
P53
P52
P51
CP2
P2 Input(L)
P3 Input(N)
CP51
P3 Input(N)
CP1 P1
P52
P51
CP51 P57 V2
P56 V1
CP51 P56 V2
P55 V1
P55 V1
P54 V1
FG terminal
P3
P2
P54 COMMON
P53 COMMON
CP2
CP1
P1
P4
CP52 P53 COMMON
P52 COMMON
P51 V3
P52 COMMON
P51 V3
P57
P4 FG(Primary)
P57 FG(Secondary)
P4 FG(Primary)
P58 FG(Secondary)
FG terminal
1
2
3
AC input terminals(L, N)
4
DC output common terminal(COMMON)
Connect to AC.100/120V or AC.200/240V single phase input line.
Connect to load.
Frame ground terminal(G)
Connect to earth ground. This is connected to the case.
DC output terminals(V1, V2, V3)
Connect to load.
COMMON SPECIFICATIONS
Temperature and humidity
MRW-135
MRW-150, 151, 160, 161
0 to +60 1
MRW-170, 171
MRW-350
0 to +70 1
–40 to +75
Operating(°C)
Temperature range
Humidity range
Storage(°C)
–25 to +75
Operating(%)RH
Storage(%)RH
20 to 95[Maximum wet-bulb temperature: 35°C, without dewing]
Amplitude and vibration
5 to 10Hz
All amplitude 10mm[3 directions, each 1h]
Acceleration 19.6m/s2 [2G, 3 directions, each 1h]
196m/s2 [20G, 3 directions, each 3 times]
11±5ms
Amplitude
10 to 55Hz
Acceleration
Vibration time
Vibration
Withstand voltage and insulation resistance
Input terminal to ground terminal(
)
)
Withstand voltage
Eac(kV)2, 1min[Normal temperature, normal humidity, cutout current 10mA]
Input terminal to output terminal
Input terminal to ground terminal(
Input terminal to output terminal
Output terminal to ground terminal(
Insulation resistance
Edc(V)500, 100MΩ min. [Normal temperature, normal humidity]
)
1 Derating is necessary when operating environment temperature exceed 50°C.
All specifications are subject to change without notice.
A111_MRW
(15/19)
TDK Switching Power Supply
Characteristics, Functions, and Applications
OUTPUT POWER-AMBIENT TEMPERATURE(DERATINGS)
OUTPUT POWER-AMBIENT TEMPERATURE(DERATINGS)
MRW-135,150,151
MRW-170,171
MRW-350
MRW-160,161
100
80
100
80
70
60
60
40
20
Available operating range
(outside of warranty)
40
20
Available operating range
(outside of warranty)
–10
0
10
20
30
40 50
60
70
–10
0
10
20
30
40
50
60
Ambient temperature(°C)
Ambient temperature(°C)
SURGE CURRENT, START UP TIME AND HOLD UP TIME
TEMPERATURE: 25°C
POWER OK SIGNAL
If the output voltage level of V1 (+5V) is 4.5V or higher, the POK
(POWER OK SIGNAL) signal is outputted from the connector
CP54.
54A(AC.120V), 27A(AC.100V)
Example: MRW-150
Input
Surge current
current
V1(+5V)
4.5Vmin.
2ms max.
(AC.120V)
Input ON
Input OFF
1.2Vmax.
+12V
(AC.264V)
(AC.220V)
(AC.95V)
(AC.95V)
+5V
(AC.264V)
(AC.120V)(AC.220V)
"H"
Output
current
POK Signal
"L"
5 to 10ms
Rise time
"H"=2.5V min.
"L"=0.4V max.
130ms
160ms
• The POK signal relates to an output voltage. An abnormality of
an input voltage is not detected.
–12V
30ms
16ms
140ms
380ms
210ms
620ms
Hold up time
Start up time
All specifications are subject to change without notice.
A111_MRW
(16/19)
TDK Switching Power Supply
Characteristics, Functions, and Applications
OUTPUT CURRENT COMBINATION
Use the output currents within the shaded range.
Example: MRW-151
Example: MRW-150
(
)
( )
V3 –15V Output current A
(
)
( )
V3 –12V Output current A
4
3
2
1
4
3
2
1
0A
0A
0.1A
0.1A
0.3A
0.25A
0
(0.5)
1
2
3
0
(0.6)
1
(
2
(
3
(
)
( )
)
)
V2 +15V Output current A
V2 +12V Output current A
Example: MRW-160
Example: MRW-161
(
)
( )
V3 –12V Output current A
(
)
( )
V3 –15V Output current A
6
5
4
3
2
1
6
5
4
3
2
1
V3=0A
0A
0.4A
0.5A
0
(0.6)
1
2
3
0
(0.5)
1
2
(
)
( )
V2 +12V Output current A
(
)
( )
V2 +15V Output current A
Example: MRW-171
Example: MRW-170
(
)
( )
V3 –15V Output current A
(
)
( )
V3 –12V Output current A
7
7
6
5
4
3
2
0.3A
0.3A
6
5
4
3
2
1.7A
2.5A
1.3A
2A
(0.8)
1
0
(0.8)
1
0
(0.3)
1
2
3
(0.3)
1
2
3
(
)
( )
(
)
( )
V2 +15V Output current A
V2 +12V Output current A
All specifications are subject to change without notice.
A111_MRW
(17/19)
TDK Switching Power Supply
Characteristics, Functions, and Applications
V2 (+12) OUTPUT PEAK CURRENT
ALLOWABLE LOAD CAPACITY OF OUTPUT EXTERNAL
CAPACITOR
While the peak current can be outputted at the V2 (+12) output in
the MRW-135, use it within the range described below.
(×1000µF) 10
Notes: 1. This graph shows capacitance of an
external capacitor(max.) for the V1
(+5V) and V2(+12) outputs. Apply
loads within the range shown in this
graph.
2. A rise of the output voltage may be
unsuccessful outside this graph.
9
8
7
6
5
4
3
2
1
MRW-135
If the 12V output exceeds 1.5A, the time should be 3 sec max.
and the effective current be 1.5A max.
For example, use the following current in the case of a waveform
shown below:
aT 3(s)
2
2
aI1 +(1-a)I2
1.5(A)
l1
aT
l2
10
20
30
40
50 (×1000µF)
0
Capacitance of external capacitor for V1(+5V)output [C1]
T
Maximum load capacity
Allowable value
Part No.
V1(+5V)
V2(+NV)
V3(–NV)
Graph
2
2
C1 max.(µF) C2 max.(µF) C3 max.(µF) C1V1 +C2V2
MRW-135 57,000
MRW-150 17,000
MRW-160 28,000
MRW-161 28,000
10,000
3,000
5,000
3,200
—
1,425,000
425,000
700,000
700,000
2
1
3
4
2,400
2,400
2,400
Note: For information other than the above, please contact us.
All specifications are subject to change without notice.
A111_MRW
(18/19)
TDK Switching Power Supply
Characteristics, Functions, and Applications
CONNECTOR
Input or output connectors and the FG terminal connectors are as follows.
MRW-135
Part No.
CP2
Designation
Installation connector
5096-02C(MOLEX)
82200
Housing
Contact
Suitable sample wire
Input
5195-03
Faston® 250 SERIES
5194TL
AWG#18-#24
CP1
CP51
CP52
Output
Output
5045-04A(MOLEX)
5045-08A(MOLEX)
5102-04
5103TL
5103TL
AWG#22-#28
AWG#22-#28
5102-08
MRW-150, 151, 160, 161
Part No.
CP1
Designation
Installation connector
5277-02A(MOLEX)
Housing
Contact
Suitable sample wire
Input
5195-03
5194TL
AWG#18-#24
CP2
P90(KOHWA) or 170267-1(AMP)
Faston® 250 SERIES
CP51
CP52
CP53
Output
POK
5045-04A(MOLEX)
5045-02A(MOLEX)
5102-04
5102-02
5103TL
5103TL
AWG#22-#28
AWG#18-#28(MRW-150)
CP54
AWG#22-#28(MRW-140,160,161)
MRW-170, 171
Part No.
CP2
Designation
Installation connector
5289-02A(MOLEX)
Housing
Contact
Suitable sample wire
Input
5199-02
5194TL
AWG#18-#24
CP1
82200(KYOSHIN) 170267-1(AMP)
5273-07A(MOLEX)
Faston® 250 SERIES
CP51
Output
5239-07
5168TL
AWG#22-#28
MRW-350
Part No.
CP1
Designation
Installation connector
Housing
Contact
Suitable sample wire
Input
5289-02A(MOLEX)
5199-02
5194TL
AWG#18-#24
CP2
82200(KYOSHIN) or170267-1(AMP) Faston® 250 SERIES
CP51
Output
5273-06A(MOLEX) 5239-06
5168TL
AWG#22-#28
Faston® is registered trademark of AMP Incorporated.
All specifications are subject to change without notice.
A111_MRW
(19/19)
TDK Switching Power Supply
Characteristics, Functions, and Applications
SOLD SEPARATELY PRODUCTS
(1) FRAME AND COVER
Item
Part No.
Applicable type
Shapes and dimensions(mm)
(165)
(122)
Frame
Cover
2JF00B157
2JC0ZB156
MRW-150
MRW-151
Frame
4-M4 tap
Cover
For cover mounting screw M3
Frame
Cover
2JF00B167
2JC0ZB166
MRW-160
MRW-161
(165)
(110)
Frame
Iron galvanized and chromized
• An order should be placed with the part number.
(2) INPUT AND OUTPUT CABLES
Type of wire in use
Input and output
Applicable type
set
Input cable
Output cable
FG cable
Power OK signal cable
No
MRW-135
MRW-150
-151
4EU20B241
4EU40B153
AWG18
AWG24
AWG18
AWG24
MRW-160
-161
4EU40B153
• Length of wire: 1m type in all cases
• An order should be placed with the input-output cable set part number. A set of required cables are included.
A111_MRW
001127
All specifications are subject to change without notice.
相关型号: