NV700 [TDK]
AC-DC电源;型号: | NV700 |
厂家: | TDK ELECTRONICS |
描述: | AC-DC电源 |
文件: | 总6页 (文件大小:1362K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
NV-350 / NV-700
uk.tdk-lambda.com/nvmodular
product.tdk.com/en/power/nv
350W - 1150W Modular power
supply.
Medical
Industrial
Test
Broadcast
Renewable
Comms
Features
Benefits
•ꢀHighꢀefficiency
Minimisesꢀheatꢀinꢀsystem
•ꢀLowꢀprofile
Fits 1U applications
•ꢀHighꢀpowerꢀdensity
Requires less space
•ꢀHigh peak power rating
Enablesꢀuseꢀofꢀsmallerꢀpowerꢀsupply
Low cost of ownership
•ꢀ3ꢀyearꢀwarranty
Input
47 - 63Hz
(440Hz with reduced PFC - consult sales office)
Input Voltage
Input Harmonics
Input Fuse
90-264Vac
Input Frequency
EN61000-3-2 compliant
Inrush Current
(cold start)
NV-350 <30A
NV-700 <40A
at 25°C and 264Vac
at 25°C and 230Vac
NV-350 = 6.3A, NV-700 = 16A
HBC Fast acting (not user accessible)
Earth Leakage
Current
130µA at 120Vac (60Hz), 260µA max at 240Vac (60Hz)
Worst case leakage current is less than 300µA at 264Vac, 63Hz (normal condition, 0.5mA Single Fault Condition)
How To Create A Product Description
The extensive range of output modules and options make it possible to achieve almost any combination of Volts and Amps. You can create
your own NV350 or NV700 configuration online at www.nv-power.com. This method checks your configuration and offers the optimum solution.
Alternatively, you can do this manually by using the guide below.
1.
Calculate total output power to select the appropriate converter, then select required Cooling, Connection and Controls/Signals from the
following table:
NV3
or
NV3 350 / 660W
NV7 700 / 1150W
Converter
S
S
S
EN5V
NV7
S
V
R
C
Standard air - forward
Variable speed fan - forward6
Reverse air4
Cooling
Customer air - no fan1
Input
Connection
S
I
Screw
IEC3202
Leakage
Current
130µA max at 120Vac (60Hz),
260µA max at 240Vac (60Hz)5
S
Standard
ES5V ac good, psu enable, 5V/2A standby
ES12V ac good, psu enable, 12V/1A standby
IS5V ac good, psu inhibit, 5V/2A standby
Primary
Option3
IS12V ac good, psu inhibit, 12V/1A standby
EN5V ac good, psu enable, 5V/2A standby global module good
EN12V ac good, psu enable, 12V/1A standby global module good
IN5V ac good, psu inhibit, 5V/2A standby global module good
IN12V ac good, psu inhibit, 12V/1A standby global module good
1 - Thermocoupled sample recommended to ensure adequate cooling - consult sales
2 - Not with customer air Cooling
3ꢀ-ꢀTheꢀPrimaryꢀOptionꢀusesꢀ1ꢀslot.ꢀLeaveꢀblankꢀforꢀnoꢀprimaryꢀoption.
4 - Not with NV7
5ꢀ-ꢀWorstꢀcaseꢀleakageꢀcurrentꢀisꢀlessꢀthanꢀ300μAꢀatꢀ264Vac,ꢀ63HzꢀNormalꢀConditionꢀ(<500μAꢀSingleꢀFaultꢀCondition)
6ꢀ-ꢀRecommendedꢀforꢀnewꢀdesignsꢀforꢀNV-350.ꢀNotꢀwithꢀNV7ꢀ(variableꢀspeedꢀfanꢀstandardꢀonꢀNV7).
NV350_NV700_Datasheet_69528 - v27.0
1
NV-350 / NV-700
2.
3.
Select Output Modules from the Module Tables below ensuring that no more that 6 slots (NV-350) or 8 slots (NV-700) in total are used.
Example - if you require 13V / 20A :-
a) Select B as closest match for voltage & current and prefix with voltage eg 13BH
b) Repeat for other outputs.
This will create a complete product description eg NV3SSSES5V 13BH 12/15DB which represents a three output NV350 with Forward air
cooling, Screw input terminals, standard leakage filter, ac good, PSU enable & 5V/2A aux supply
Output 1 = 13V / 20A. Output 2 = 12V / 13A with screw terminals. Output 3 = 15V / 4A with screw terminals
Max 350W continuous output power
Contact TDK-Lambda to validate configuration and issue a part number.
DUAL OUTPUT MODULES
SINGLE OUTPUT MODULES
Module
Output 1
Output 2
Module
Output 1
Current
Max
Power
48W8
Code Slots
Voltage Range Continuous Peak
Code Slots
Voltage Range Current Voltage Range Current
3.2
4.75
7
-
-
-
-
-
-
-
-
-
-
-
-
3.6
5.5
9
15.5
28
13.2
16.5
26.4
32
40A
40A3
22.5A4
20A5
10A6
37.5A7
30A7
18.75A7
16.6A7
18.75A7
18.75A9
16.6A9
18
DA
12 (fixed)
3A
-12 (fixed)
1A
10A
5A
2A
10A
5A
B
2
2
3.3
-
-
-
-
-
-
-
-
-
-
-
-
-
5.5
55W
60W
50W
55W
60W
50W
55W
55W
60W
50W
55W
60W
50W
DB
2
3.2
-
3.6
25A
7
24
3.3
7
15
32
5.5
15
32
5.5
5.5
15
32
5.5
15
32
12
24
12
15
24
27
24
48
54
BH
50A7
37.5A7
25A7
19.7A7
25A7
DB
DB
DB
2
2
2
4.75
5.5
12
-
-
-
5.5
6.5
15
25A
25A
13A1
24
3.3
3.3
7
2A
C
3
10A
10A
5A
2A
10A
5A
CM
CC
3
6
26.4
52.8
64
24
3.3
7
25A9
19.7A9
DB
2
24
-
28
7A2
24
2A
Higherꢀoutputꢀvoltagesꢀavailableꢀbyꢀconnectingꢀoutputꢀ
modules in series. Contact technical support for details
1.ꢀDerateꢀlinearlyꢀfromꢀ13Aꢀatꢀ12.5Vꢀtoꢀ10Aꢀatꢀ15.5V
2.ꢀDerateꢀlinearlyꢀfromꢀ7Aꢀatꢀ25Vꢀtoꢀ6Aꢀatꢀ28V
3.ꢀForꢀNV3ꢀ-ꢀderateꢀlinearlyꢀfromꢀ40Aꢀatꢀ5.2Vꢀtoꢀ36Aꢀatꢀ5.5V
ꢀꢀꢀꢀForꢀNV7ꢀ-ꢀderateꢀlinearlyꢀfromꢀ40Aꢀatꢀ5Vꢀtoꢀ36Aꢀatꢀ5.5V
4.ꢀDerateꢀlinearlyꢀfromꢀ22.5Aꢀatꢀ8Vꢀtoꢀ20Aꢀatꢀ9V
6.ꢀForꢀNV3ꢀ-ꢀderateꢀlinearlyꢀfromꢀ10Aꢀatꢀ25.7Vꢀtoꢀ8.5Aꢀatꢀ28V
ꢀꢀꢀꢀForꢀNV7ꢀ-ꢀderateꢀlinearlyꢀfromꢀ10Aꢀatꢀ24Vꢀtoꢀ8.5Aꢀatꢀ28V
7. For NV3 - 400W max
ꢀꢀꢀꢀForꢀNV7ꢀ-ꢀ600Wꢀpeakꢀforꢀupꢀtoꢀ10sec,ꢀ450Wꢀaverageꢀ
8.ꢀOnlyꢀoneꢀperꢀpowerꢀsupply,ꢀ48Wꢀmaxꢀtotalꢀpowerꢀforꢀmodule
9.ꢀForꢀNV3ꢀ-ꢀlimitedꢀbyꢀtotalꢀoutputꢀpower,ꢀseeꢀbelow
5.ꢀForꢀNV3ꢀ-ꢀderateꢀlinearlyꢀfromꢀ20Aꢀatꢀ13.2Vꢀtoꢀ16.5Aꢀatꢀ15.5V
ꢀꢀꢀꢀForꢀNV7ꢀ-ꢀderateꢀlinearlyꢀfromꢀ20Aꢀatꢀ12.5Vꢀtoꢀ15.5Aꢀatꢀ15.5V
OUTPUT POWER
90-115Vac
115-150Vac 150-180Vac 180-264Vac
Comments
5. 1150W average
Continuous6
Peak (10s)7
Continuous
Peak (10s)
350W
400W1
700W
450W
500W2
700W
850W4
450W
500W2
1150W
1150W
660W
740W3
1150W
1450W5
1. 350W average
2. 450W average
3. 600W average
4. 700W average
NV-350
NV-700
6. 250W for reverse air
7. Not for reverse air
Output Specification
Voltage / Current
Turn on time
See module tables
1.5s max
<50ms
at 90Vac and 100% rated output power
Rise time
to 90% of voltage, monotonic rise above 10% (27-32V C module < 100ms)
configuration dependent
Efficiency
up to 90%
16ms min
Hold up
at 90Vac and 100% rated power (12ms for NV-700)
Ripple and Noise
Voltage Accuracy
<1% or 50mV if greater pk-pk, using EIAJ test method & 20MHz bandwidth
<1%
Yes
of set voltage (DA module: +5/-1% for channel 1, +2/-3.5% for channel 2)
standard on single o/p + ch1 of dual modules, max 0.5V total line drop
(DA module: None)
Remote Sense
Minimum Load
No
<0.02%
<1%
on any output (DA module: 150mA on channel 1)
of rated voltage per °C
Temperature Coefficient
Load Regulation
Line Regulation
for 0-100% load change (<2% for channel 2) (DA module: <3%)
for 90-264Vac input change
<0.1%
<0.1%
<4%
Cross Regulation
Transient Response
Recovery
for 100% load change on any output (DA module: 0.2% for channel 1, 3% for channel 2)
of set voltage for 50% load change
500µs
Yes
for recovery to 1% of set voltage (DA module: 1000µs)
Over Voltage Protection
NV350_NV700_Datasheet_69528 - v27.0
NV-350 / NV-700
2
Output Specification
Over Current Protection (singles)
110-150%
110-150%
Yes
of module current. Hiccup mode. Module primary side protected
of max Power ch1 + ch2. Hiccup mode. Module primary side protected
(DA module: 110-220% for channel 1, 110-170% for channel 2)
Power Limit (duals)
Short Circuit Protection
Over Temperature Protection
cycle ac off/on to reset
Yes
Shutdown temperature varies according to ambient, output power and input voltage.
Isolation
2 x MOPPs (3rd edition 60601)
Reinforced 4kVac, 5.7kVdc type tested to 4kVac (equivalent to
5.7kVdc), production tested to 4.3kVdc.
Outputs from C, CC, CM or CMCM modules only
Input to Output
2 x MOOPs (3rd edition 60601)
Reinforced
Units with any other module or primary option fitted
4.3kVdc (Basic for 2nd edition 60601)
Input to Earth
Basic
2.3kVdc
200Vdc
Output to Earth
CM modules are 500Vac
Signalsꢀ(allꢀsignalsꢀreferencedꢀtoꢀ0Vꢀofꢀchannel)
Ch1/Ch2 Module Good
Open collector output. ‘On’ indicates output is within 90% (± 5%) of nominal
TTL logic high inhibits the output (both outputs for duals) of the module
TTL logic low inhibits output 2 of the module
Module inhibit
Ch2 On/Off (duals only)
Global Interface Signals - units fitted with primary option
AC good collector
AC good emitter
Uncommitted optocoupler. See application note for timings.
Global module good collector Uncommitted optocoupler. See application note for timings.
Global module good emitter
EN/ES and IN/IS Logic 0
EN/ES and IN/IS Logic 1
Standby Supply
Do not connect for ES and IS type primary options.
TTL low enables (EN or ES) or inhibits (IN or IS) the entire psu including fan (except standby)
TTL high enables (EN or ES) or inhibits (IN or IS) the entire psu including fan (except standby)
5V / 2A (2.5A peak) or 12V / 1A (1.2A peak)
Environment
Temperature
Derating
0°C to 50°C operational, -40°C to 70°C storage (max 12 months).
50°Ca to 70°C derate total output power and each output current by 2.5% per °C
Low Temp Startup
Humidity
-20°C
5 - 95% RH non condensing
±3 x 30g shocks in each plane, total 18 shocks
Shock
30g shock = 11ms (+/-0.5msec), half sine
Conforms to EN60068-2-27, EN60068-2-47, IEC68-2-27, IEC68-2-47, JIS C0041-1987.
Vibration
Altitude
Single axis 10 - 500 Hz at 2g (sweep and endurance at resonance) in all 3 planes
3000/5000 metres operational (5000 metres non operational). See handbook for limitations of use.
Degree 2, Material group IIIb
Pollution
a - 45°C for NV7 with input voltage below 100Vac
Immunity EN61000-6-2:2005, EN60601-1-2:2007
Criteria
Air discharge 15kV, Contact discharge 8kV
12V/m
A
Electrostatic Discharge
EN61000-4-2
Level 4
Level 3
Electromagnetic Field
EN61000-4-3
A
ac input tested to 4.4kV
dc output tested to 2.2kV
Fast / Burst Transient
EN61000-4-4
Level 4
A
Common mode - 2.2kV, Differential - 1.1kV
Surge Immunity
EN61000-4-5
EN61000-4-6
EN61000-4-8
Level 3
Level 3
Level 4
A
A
A
12V
Conducted RF Immunity
Power Frequency Magnetic Field
30A/m
Criteria B for 5 sec interruption
Dip to 40% for 5 cycles:
NV350 - criteria B below 154Vac input at 350W output, criteria B at 660W output
NV700 - criteria B below 198Vac input at 700W output, criteria B at 1150W output
Voltage Dips, Variations, Interruptions EN61000-4-11 Class 3
A
A
Voltage Fluctuations
EN61000-4-14 Class 3 For 100 - 240V Nominal
NV350_NV700_Datasheet_69528 - v27.0
3
NV-350 / NV-700
Emissions EN61000-6-3:2007, EN60601-1-2:2007
(as per CISPR.11/22) Class B, FCC47 part 15 subpart B
see application note for details. Additional filtering required for IEC inlet version.
Radiated Electric Field
EN55011, EN55032
Conducted Emissions
Conducted Harmonics
Flicker
EN55011, EN55032
EN61000-3-2
(as per CISPR.11/22) Class B, FCC47 part 15 subpart B
Class A
EN61000-3-3
Compliant - dmax only
Approvals / Accreditations
IEC/EN 60950-1, UL60950-1 / CSA 22.2 No 60950-1
File E135494
IEC/EN 60601-1, UL/CSA 60601-1, ANSI/AAMI ES60601-1
CAN/CSA-C22.2 No 60601-1-08
File E349607
IEC/EN 61010-1
File E331788
CE Mark (EN60950-1)
LV Directive 2006/95/EC
CB certificate and Report available on request
Please check with technical sales for status of approvals
Designed and manufactured under the control of ISO9001 and ISO13485 (including risk management).
PRIMARY OPTION / DA MODULE
Primary Option
1ꢀꢀ+VꢀStandby
2ꢀꢀ0VꢀStandby
DA Module
1ꢀꢀ+12Vꢀ(channelꢀ1)
2ꢀꢀ+12Vꢀ(channelꢀ1)
3ꢀꢀ+12Vꢀ(channelꢀ1)
4ꢀꢀ0Vꢀ(commonꢀch1ꢀ/ꢀch2)
5ꢀꢀ0Vꢀ(commonꢀch1ꢀ/ꢀch2)
6ꢀꢀ0Vꢀ(commonꢀch1ꢀ/ꢀch2)
7ꢀꢀ-12Vꢀ(channelꢀ2)
8ꢀꢀ-12Vꢀ(channelꢀ2)
3ꢀꢀEN/ESꢀ&ꢀIN/ISꢀLogicꢀ1
4ꢀꢀEN/ESꢀ&ꢀIN/ISꢀLogicꢀ0
5 Global Module Good Collector
6 Global Module Good Emitter
7ꢀꢀACꢀgoodꢀCollector
8ꢀꢀACꢀgoodꢀEmitter
Housing: Molex 51110-0860
Crimp pin: 50394
Hand crimp tool: 69008-0959
Outsideꢀofꢀ
Option End ViewChassis
NV350_NV700_Datasheet_69528 - v27.0
NV-350 / NV-700
4
22.20
225.80
Standard
air flow
Side View NV-350 / NV-700
Reverse
airflow
Side View NV-350 / NV-700
15.00
NOTES
Customer fixings M4. Maximum screw penetration
4.5mm. Maximum torque 1.5Nm
1) Dimensions in mm
2) Tolerances:
Edge to edge/Edge to centre, +/-0.5
Centre to centre +/-0.2
32.00
199.20
NV-350
Screw Terminal
NV-350
IEC Inlet
Bottom View NV-350
256.70 (Screw terminal version)
275.40 (Outside of fan and IEC endcap)
NV-350
4.00
NV-700
E
N
L
E
N
L
3.00
24.90
Screw Terminal
ac Inlet
IEC320 ac inlet
bottom view end view
Screw Terminal
ac Inlet
IEC320 ac inlet
bottom view
end view
NV-700
Screw Terminal
NV-700
IEC Inlet
Bottom View NV-700
NV350_NV700_Datasheet_69528 - v27.0
5
NV-350 / NV-700
TDK-Lambda France SAS
TDK-Lambda Americas
Tel: +1 800-LAMBDA-4 or 1-800-526-2324
powersolutions@us.tdk-lambda.com
www.us.lambda.tdk.com
Tel: +33 1 60 12 71 65
france@fr.tdk-lambda.com
www.emea.lambda.tdk.com/fr
Italy Sales Office
Tel: +39 02 61 29 38 63
info.italia@it.tdk-lambda.com
www.emea.lambda.tdk.com/it
TDK Electronics do Brasil Ltda
Tel: +55 11 3289-9599
sales.br@tdk-electronics.tdk.com
www.tdk-electronics.tdk.com/en
Netherlands
info@nl.tdk-lambda.com
www.emea.lambda.tdk.com/nl
TDK-Lambda Germany GmbH
Tel: +49 7841 666 0
info.germany@de.tdk-lambda.com
TDK-Lambda Corporation
Tel: +81-3-6778-1113
www.jp.lambda.tdk.com
www.emea.lambda.tdk.com/de
TDK-Lambda (China) Electronics Co. Ltd.
Tel: +86 21 6485-0777
powersolutions@cn.tdk-lambda.com
www.lambda.tdk.com.cn
TDK-Lambda Singapore Pte Ltd.
Tel: +65 6251 7211
tls.mkt@sg.tdk-lambda.com
www.sg.lambda.tdk.com
Austria Sales Office
Tel: +43 2256 655 84
info@at.tdk-lambda.com
www.emea.lambda.tdk.com/at
TDK India Private Limited, Power Supply Division
Switzerland Sales Office
Tel: +41 44 850 53 53
info@ch.tdk-lambda.com
www.emea.lambda.tdk.com/ch
Tel: +91 80 4039-0660
mathew.philip@in.tdk-lambda.com
www.sg.lambda.tdk.com
Nordic Sales Office
Tel: +45 8853 8086
info@dk.tdk-lambda.com
www.emea.lambda.tdk.com/dk
TDK-Lambda UK Ltd.
Tel: +44 (0) 12 71 85 66 66
powersolutions@uk.tdk-lambda.com
www.emea.lambda.tdk.com/uk
TDK-Lambda Ltd.
Tel: +9 723 902 4333
info@tdk-lambda.co.il
www.emea.lambda.tdk.com/il
C.I.S.
Commercial Support:
Tel: +7 (495) 665 2627
Technical Support:
Tel: +7 (812) 658 0463
info@tdk-lambda.ru
www.emea.lambda.tdk.com/ru
Forꢀadditionalꢀinformation,ꢀpleaseꢀvisitꢀ
product.tdk.com/en/power
Errors and omissions excepted
NV350_NV700_Datasheet_69528 - v27.0