PXD60-48WS3P3 [TDK]
DC-DC开关电源;型号: | PXD60-48WS3P3 |
厂家: | TDK ELECTRONICS |
描述: | DC-DC开关电源 开关 |
文件: | 总7页 (文件大小:2056K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
PXD60 Series
https://product.tdk.com/en/power/pxd
www.emea.lambda.tdk.com/pxd
60W Single and Dual Output DC-DC converters
The PXD60 industrial DC-DC converters feature wide 4:1 input ranges in a compact 2 x 1” (50.8 x 25mm) industry standard package. With efficiencies up
to 92%, the PXD60 series typically draws a low 3mA input current when the remote on/off function is used, prolonging battery life for portable equipment. The
modules have six-sided shielding to reduce radiated noise.
Features
Benefits
• Wide 4:1 Input Range
• Supports Dual 12/24V or 24/48V System Voltages
• Less Board Area Needed
• Suitable For Industrial Applications
• Longer Battery Life
• Compact 2” x 1” Industry Package
• Certified to IEC/UL/CSA/EN 62368-1
• Low No Load Power Consumption
• Six Sided Shielding
• Reduces Radiated Noise
Model Selector
Model
Input
Voltage (V)
Output
Voltage (V)
Maximum
Current (A)
Maximum No Load Input
Power (W) Current (mA)
Efficiency
Maximum Load
Capacitance (uF)
(%)
Single Outputs
PXD60-24WS3P3
PXD60-48WS3P3
PXD60-24WS05
PXD60-48WS05
PXD60-24WS12
PXD60-48WS12
PXD60-24WS15
PXD60-48WS15
PXD60-24WS24
PXD60-48WS24
Dual Outputs
PXD60-24WD12
PXD60-48WD12
PXD60-24WD15
PXD60-48WD15
PXD60-24WD24
PXD60-48WD24
9 - 36
18 - 75
9 - 36
18 - 75
9 - 36
18 - 75
9 - 36
18 - 75
9 - 36
3.3
3.3
5
12
12
12
12
5
5
4
4
2.5
2.5
39.6
39.6
60
60
60
60
60
60
60
10
10
10
10
10
10
10
10
10
10
90
90
92
92
92
92
92
92
92
91
32,000
32,000
30,000
30,000
5,850
5,850
3,900
3,900
2,000
2,000
5
12
12
15
15
24
24
18 - 75
60
9 - 36
18 - 75
9 - 36
18 - 75
9 - 36
±12
±12
±15
±15
±24
±24
±2.5
±2.5
±2
±2
±1.25
±1.25
60
60
60
60
60
60
10
10
10
10
10
10
91
91
91
91
91
91
±3,900
±3,900
±2,400
±2,400
±1,000
±1,000
18 - 75
PXD
60
-24W
S
05
-N
-HC2
3P3 3.3V Output Voltage
05 5V Output Voltage
12 12V Output Voltage
15 15V Output Voltage
24 24V Output Voltage
60 60W Output Power
-24W 9 - 36V input
-48W 18 - 75V input
S Single Output
D Dual Output
Blank Positive Logic
Remote On/Off
-N
Negative Logic
Remote On/Off
Blank No heatsink fitted
-HC1 Factory installed heatsink with 7.62mm fins
-HC2 Factory installed heatsink with 12.7mm fins
-HC3 Factor installed heatsink with 20.32mm fins
Preferred model
Example: PXD60-24WS3P3-N-HC2
1
PXD60 Series
Related Products
Type
Part Number
Description
Heatsink kit (User installation)
Heatsink kit (User installation)
Heatsink kit (User installation)
ACC-PX2X1-HC01
ACC-PX2X1-HC02
ACC-PX2x1-HC03
HC1 heatsink, thermal pad and 2 clips
HC2 heatsink, thermal pad and 2 clips
HC3 heatsink, thermal pad and 2 clips
Specifications
Model
PXD60
Input
Input Voltage Range
Input Surge Voltage
Input Shutdown Voltage
Start-up Time
-
See model selector table
-24W models: 50, -48W models: 100. (1s maximum)
-24W models: 7 - 8.8, -48W models: 15 - 17.5
60 typical
Vdc
Vdc
ms
No Load Current Consumption
Efficiency
-
-
-
-
-
See model selector table. Typically 3mA if remote on/off is activated
See model selector table
Conducted & Radiated EMI
Immunity
EN55032. See instruction manual on website for external circuitry
See immunity section
Safety Certifications and Markings
IEC/UL/CSA/EN62368-1, CE Mark and UKCA Mark
Immunity
Test
Standard
Test Level
Criteria
Notes
ESD
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
Air ± 8kV and Contact ± 6kV
A
A
A
A
A
A
-
Radiated Susceptibility
Electrical Fast Transient Burst
Surge
20V/m
-
± 2kV
± 2kV
With an input filter of two 220uF capacitors and a TVS
(SMDJ58A for PXD60-24W or SMDJ120A for PXD60-48W)
Conducted Susceptibility
Magnetic Fields
10 Vrms
-
-
100A/m continuous; 1000A/m 1s
2
PXD60 Series
Specifications
Model
PXD60
Output
Output Voltage Tolerance
Output Voltage Adjustment
Switching Frequency
Line Regulation
%
±1
%
Single output only. 3.3V-12V, 48V: ±10, 15V-24V: -10/+20, No adjustment on dual output models.
kHz
225 - 275
±0.2
%
Load Regulation
%
Single output: ±0.5 Dual output: ±1
Dual output: ±5 (Asymmetrical 25% to 100% load change)
See model selector table
Cross Regulation
%
External Load Capacitance
Ripple & Noise (1)
Temperature Coefficient
Minimum Load
-
mVp-p
Single output: 3.3-5V outputs: <100, 12-15V outputs: <150, 24V outputs: <200
±0.02
%/°C
-
-
No minimum load required
Transient Loading
250us recovery time for a 25% load change
150, hiccup mode
Overcurrent Protection
Overvoltage Protection
Overtemperature Protection
Remote Sense
%
V
Zener clamp method. 3.3 V: 3.9, 5V: 6.2, 12V: 15, 15V: 20, 24V: 30 (typical)
Shutdown, typically 115
°C
No remote sense
Remote On/Off
-
Positive Logic (Blank): ON: Open or 3-12V, OFF Short or 0-1.2V
Negative Logic (-N suffix): ON: Short or 0-1.2V, OFF: Open or 3-12V
Environmental
Operating Temperature (2)
Maximum Case Temperature
Thermal Impedance
Storage Temperature
Humidity (non condensing)
Cooling
°C -40 to +105 - see derating section and instruction manual on website (Confirm case temperatures in end system)
°C
°C/W
°C
%RH
-
105 (Overtemperature Protection 115)
No heatsink: 10.8, -HC1: 8.3, -HC2: 7.0, -HC3: 5.7
-55 to +125
5 - 95 (Operating & Storage)
Convection or forced air
5,000 (operating)
Altitude
m
Withstand Voltage (For 1 minute)
Isolation Capacitance
Vibration (Operating)
Thermal Shock
Vdc
pF
-
Input to output to case 1,600
<2200
MIL-STD-810F
-
MIL-STD-810F
Other
Weight (Typ)
g
33 (no heatsink fitted)
Size (LxWxH)
mm
50.8 x 25.4 x 10.2 (no heatsink fitted)
Size (LxWxH)
Inches
-
2 x 1 x 0.4 (no heatsink fitted)
Case Material
Copper
858,200
3
MTBF - MIL-HDBK-217F, Full Load
Warranty
Hours
Years
Notes
See website for detailed specifications, test methods and installation manual
(1) Measured with a 20MHz bandwidth oscilloscope across an X7R multi-layer ceramic capacitor. 10uF/25V for 3.3 to 15V outputs, 4.7uF/50V for 24V output models
(2) The case temperature must be confirmed in end application. The product rating may be affected by airflow direction and physical obstructions near the module.
3
PXD60 Series
Derating Section
PXD60-48WS12 - Derating Diagram
PXD60-48WS12 - Derating Diagram
The required power reduction depends on the individual device. The example shows the PXD60-48WS12. The points A to G describe the temperatures at
which the power reduction starts. For other models, these points can be taken from the table.
A
B
C
D
E
F
G
Derating Starting Point
20LFM (convection)
100LFM
200LFM
500LFM
with HC1
with HC2
with HC3
PXD60-24WS3P3
PXD60-24WS05
PXD60-24WS12
PXD60-24WS15
PXD60-24WS24
PXD60-24WD12
PXD60-24WD15
PXD60-24WD24
PXD60-48WS3P3
PXD60-48WS05
PXD60-48WS12
PXD60-48WS15
PXD60-48WS24
PXD60-48WD12
PXD60-48WD15
PXD60-48WD24
61°C
50°C
43°C
51°C
51°C
39°C
50°C
48°C
61°C
50°C
45°C
44°C
45°C
39°C
45°C
48°C
77°C
70°C
67°C
72°C
72°C
65°C
71°C
70°C
77°C
70°C
68°C
67°C
68°C
65°C
68°C
70°C
85°C
80°C
77°C
80°C
80°C
75°C
80°C
78°C
85°C
80°C
77°C
77°C
78°C
75°C
78°C
79°C
89°C
85°C
82°C
85°C
85°C
81°C
84°C
84°C
89°C
85°C
84°C
82°C
83°C
81°C
83°C
84°C
71°C
62°C
58°C
64°C
64°C
55°C
62°C
61°C
71°C
62°C
59°C
58°C
59°C
55°C
58°C
61°C
77°C
69°C
65°C
70°C
70°C
62°C
69°C
68°C
77°C
69°C
66°C
65°C
66°C
62°C
66°C
68°C
82°C
76°C
72°C
77°C
77°C
70°C
76°C
75°C
82°C
76°C
73°C
73°C
73°C
70°C
73°C
75°C
4
PXD60 Series
Pinout
Outline Drawing
PIN
Function
Single
Dual
1
2
3
4
5
6
+Vin
-Vin
Ctrl
+Vout
-Vout
Trim
Com
-Vout
1. All dimensions in inch (mm)
Tolerance: x.xx±0.02 [x.x ± 0.5]
x.xx±0.02 [x.x ± 0.25]
2. Pin dimension tolerance ±0.004 [0.10]
Recommended PCB Layout
Recommended PCB Layout
All dimensions in inch[mm]
Pad size(lead free recommended)
Through hole 1.2.3.4.5.6: Φ0.051[1.30]
Top view pad 1.2.3.4.5.6: Φ0.064[1.63]
Bottom view pad 1.2.3.4.5.6: Φ0.102[2.60]
5
PXD60 Series
Heat-Sink Type Options
HC1
HC2
HC3
1. All dimensions in inch [mm]
2. Tolerance :x.xx±0.02 [x.x±0.5]
x.xxx±0.010 [x.xx±0.25]
6
PXD60 Series
TDK-Lambda France SAS
TDK-Lambda Americas
Tel: +1 800-LAMBDA-4 or 1-800-526-2324
powersolutions@us.tdk-lambda.com
www.us.lambda.tdk.com
Tel: +33 1 60 12 71 65
france@fr.tdk-lambda.com
www.emea.lambda.tdk.com/fr
Italy Sales Office
Tel: +39 02 61 29 38 63
info.italia@it.tdk-lambda.com
www.emea.lambda.tdk.com/it
TDK Electronics do Brasil Ltda
Tel: +55 11 3289-9599
sales.br@tdk-electronics.tdk.com
www.tdk-electronics.tdk.com/en
Netherlands
info@nl.tdk-lambda.com
www.emea.lambda.tdk.com/nl
TDK-Lambda Germany GmbH
Tel: +49 7841 666 0
info@de.tdk-lambda.com
TDK-Lambda Corporation
Tel: +81-3-6778-1113
www.jp.lambda.tdk.com
www.emea.lambda.tdk.com/de
TDK-Lambda (China) Electronics Co. Ltd.
Tel: +86 21 6485-0777
powersolutions@cn.tdk-lambda.com
www.lambda.tdk.com.cn
TDK-Lambda Singapore Pte Ltd.
Tel: +65 6251 7211
tls.mkt@sg.tdk-lambda.com
www.sg.lambda.tdk.com
Austria Sales Office
Tel: +43 2256 655 84
info@at.tdk-lambda.com
www.emea.lambda.tdk.com/at
TDK India Private Limited, Power Supply Division
Switzerland Sales Office
Tel: +41 44 850 53 53
info@ch.tdk-lambda.com
www.emea.lambda.tdk.com/ch
Tel: +91 80 4039-0660
mathew.philip@in.tdk-lambda.com
www.sg.lambda.tdk.com
Nordic Sales Office
Tel: +45 8853 8086
info@dk.tdk-lambda.com
www.emea.lambda.tdk.com/dk
TDK-Lambda UK Ltd.
Tel: +44 (0) 12 71 85 66 66
info@uk.tdk-lambda.com
www.emea.lambda.tdk.com/uk
TDK-Lambda Ltd.
Tel: +9 723 902 4333
info@tdk-lambda.co.il
www.emea.lambda.tdk.com/il
C.I.S.
Commercial Support:
Tel: +7 (495) 665 2627
Technical Support:
Tel: +7 (812) 658 0463
info@tdk-lambda.ru
www.emea.lambda.tdk.com/ru
For additional information, please visit
https://product.tdk.com/en/power/
PXD60W_260662 April 13th, 2022 V2
7
PXD60 Series
相关型号:
PXE1110CDM-G003
The Infineon Technologies enterprise digital controllers provide intelligent power for Intel™ VR12.5 and VR13 applications. Command and monitor functions are controlled through the Intel SVID interface which supports 5mV/step VID table, power states (PS), and VR Data & Configuration Register requirements. Infineon’s memory controllers utilize digital technology to implement all control functions, providing the ultimate system solution in terms of flexibility and stability.
INFINEON
PXE1610CDN-G003
The Infineon Technologies enterprise digital controllers provide intelligent power for Intel™ VR12.5 and VR13 applications. Command and monitor functions are controlled through the Intel SVID interface which supports 5mV/step VID table, power states (PS), and VR Data & Configuration Register requirements. Infineon’s memory controllers utilize digital technology to implement all control functions, providing the ultimate system solution in terms of flexibility and stability.
INFINEON
©2020 ICPDF网 联系我们和版权申明