Vega650 [TDK]

AC-DC电源;
Vega650
型号: Vega650
厂家: TDK ELECTRONICS    TDK ELECTRONICS
描述:

AC-DC电源

文件: 总6页 (文件大小:1319K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Vega Series  
https://emea.lambda.tdk.com/vega  
https://product.tdk.com/en/power/vega  
450W - 900W  
Modular power supply.  
Medical  
Industrial  
Test  
Broadcast  
Renewable  
Comms  
Features  
Benefits  
Industryꢀleadingꢀflexibility  
Suits your application  
Screw, Fast-on or IEC connection  
Worldwide safety approvals  
Up to 11 outputs  
Simplifiesꢀdesignꢀintoꢀsystem  
Supports global use  
Eliminates need for additional supplies  
Low cost of ownership  
3 year warranty  
Input  
Vega 450, 650 and 900  
Vega dc (450W)  
Input Voltage /  
Frequency  
90-264Vac / 47 - 63 Hz (440Hz with reduced PFC)  
900W version is 150-264Vac only, 650W below 150Vac  
34 - 75Vdc  
derate linearly below 44V to 340W at 34V  
Input Fuse  
16A / 250Vac HBC Fast acting (not user accessible)  
<40A at 25°C and 264Vac (cold start)  
20A Fast acting (not user accessible)  
<40A at 25°C, ETSI EN300 132-2  
n/a  
Inrush Current  
Leakage Current See ‘How To Create A Product Description’ for details  
How To Create A Product Description  
The extensive range of output modules and options make it possible to achieve almost any combination of Volts and Amps. You can create  
your own Vega configuration online at https://config.emea.tdk-lambda.com/. This method checks your configuration and offers the optimum  
solution. Alternatively, you can do this manually by using the guide below.  
1.  
Calculate total output power to select the appropriate converter, then select required Cooling, Connection, Leakage Current and Controls/  
Signals from the following table:  
V4  
F
S
S
F
V0 450W (dc in)  
V4 450W  
F
ac fail, psu+fan inhibit, 5V/100mA standby  
FV ac fail, psu+fan inhibit, 5V/300mA standby  
Primary xFWcd ac fail, psu+fan inhibit, 5-15V/1A standby  
Converter  
Cooling  
V6 650W  
V9 900W  
Option  
E
ac fail, psu+fan enable, 5V/100mA standby  
F
Forward air - standard  
EV ac fail, psu+fan enable, 5V/300mA standby  
xEWcd ac fail, psu+fan enable, 5-15V/1A standby  
Qd Forward air - Quiet  
Ra Reverse air  
Pad Reverse air - Quiet fan  
Cb Customer air - no fan  
S
M
L
R
T
Standard 1.5mA  
650µA  
290µA  
175µA  
60µA  
Leakage  
Current  
(max leakage  
current at 264Vac,  
63Hz)  
S
Screw  
Input  
Connection  
Fd Fast-on terminal  
Id IEC320 with switch  
a) Not available for Vega 900  
b) Thermocoupled sample recommended to ensure adequate  
cooling - consult sales  
c)ꢀxFXꢀandꢀxEWꢀoptionsꢀincreaseꢀleakageꢀcurrentꢀbyꢀ90µA.ꢀRe-  
placeꢀ‘x’ꢀwithꢀrequiredꢀoutputꢀvoltageꢀ(5FWꢀ=ꢀ5Vꢀstandbyꢀsupply)  
d) Not available for Vega dc  
2.  
Select Output Modules and options from the output voltages tables.  
Example - if you require 5.2V / 18A with output inhibit :-  
a) Select B1H as closest match for voltage & current and prefix with voltage (eg 5.2B1H)  
b) add suffix ‘S’ or ‘F’ for Screw or Fast-on output connection (eg 5.2B1HS)  
c) add suffix ‘N’ for output inhibit if required (eg 5.2B1HSN)  
d) Repeat for other outputs.  
Ensure you do not select more than a total of 5 slots width of modules. This will create a complete product description eg V6FSSF 5L1SN  
12/12H3/3S 24C5S which represents a four output 650W Vega with Forward air, Screw terminal input, 1.5mA leakage, ac Fail, Global  
inhibit & 5V/100mA standby supply with the following outputs:  
Output 1 = 5V/35A (with output inhibit, module good and current share option). Output 2 = 12V / 10A, Output 3 = 12V / 6A, Output 4 = 24V  
/ 10A, all with screw terminal outputs.  
3.  
Contact TDK-Lambda to validate configuration and issue a part number.  
Vega_Datasheet_69537 - v21.0  
1
Vega Series  
OUTPUT VOLTAGES (single output modules)  
OUTPUT VOLTAGES (twin output modules)  
Adjustment Range Current  
V1 Adjustment Range  
V2 Adjustment Range Current  
Module  
Slots  
Module  
Current  
Slots  
(Volts)  
(Amps)  
(Volts)  
(Volts)  
(Amps)  
B1L  
C1  
1.8  
1.8  
1.8  
1.8  
1.8  
1.8  
1.8  
1.8  
3.9  
4.2  
3.8  
3.9  
3.8  
4.2  
3.8  
3.9  
3.9  
5
-
3.8e  
4.1e  
4.1e  
3.8  
20  
1
1
H1L/1L  
H1L/1H  
H1L/2  
H1L/3  
H1L/4  
H1H/1L  
H1H/1H  
H1H/2  
H1H/3  
H1H/4  
H2/1L  
H2/1H  
H2/2  
1.8  
3.9  
5.6  
9.1  
16.3  
1.8  
3.9  
5.6  
9.1  
16.3  
1.8  
3.9  
5.6  
9.1  
16.3  
1.8  
3.9  
5.6  
9.1  
16.3  
1.8  
3.9  
5.6  
9.1  
16.3  
-
3.8n  
5.5d  
9f  
8
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
35  
40  
50  
60  
80  
95  
114  
20  
35  
45  
50  
60  
66  
75  
95  
104  
25  
12  
18  
24  
40  
45  
45  
18  
30  
36  
14  
18  
27  
6
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
8
6
C1Y  
D1L  
E1  
1
1.8  
3.9  
-
-
-
-
-
3.8n  
12  
1.5  
2
16.2u  
25p  
6
3.8e  
3.8  
4.5  
8
F1a  
2
3.8n  
5.5d  
9f  
Z2  
3.8e  
3.8e  
5.5d  
5.5d  
9k  
3
8
Z3  
4
5.5d  
12  
10  
10  
5
6
B1H  
L1  
1
16.2u  
25p  
6
1
4.5  
8
D2  
1.5  
1.5  
2
3.8n  
5.5d  
9f  
D1H  
E2  
5.5d  
8k  
8
5.6  
9f  
6
Z18  
F2a  
5.5  
2
H2/3  
16.2u  
25p  
6
8
2
H2/4  
4.5  
8
Z4  
5.5d  
5.5d  
9f  
3
H3/1L  
H3/1H  
H3/2  
3.8n  
5.5d  
9f  
Z6  
3.5  
1
8
B2  
9.1  
16.2u  
6
B3  
9.1  
9.1  
8
16.2g  
16.2g  
16.5g  
13.9l  
16.5g  
16g  
21.5i  
19.9m  
15  
1
H3/3  
16.2u  
25p  
6
C3  
1
H3/4  
4.5  
8
D3  
1.5  
2
H5/1L  
H5/1H  
H5/2  
3.8n  
5.5d  
9f  
E3L  
Z7  
8
8
8
3
16.2  
28  
6
EE2  
D4  
7.6  
14  
4
H5/3  
16.2u  
25p  
6
1.5  
2
H5/4  
4.5  
E4  
14  
Wide Range Programmable Modules  
Voltage Range Current Slots  
E3H  
C4  
14  
2
Module  
W2a  
16.3  
18.2  
20  
21.5i  
32.4j  
24  
1
0.25w  
0.25x  
-
-
7.5  
32  
30  
1
1
Select features from table below  
CC3  
E5Lv  
B5  
2
W5  
8.5  
2
21.6  
21.6  
21  
31h  
31j  
1
Follow by F or T  
F or S  
Fixed or Tracking Overvoltage protection  
Fast-on or Screw output terminals  
C5  
10  
15  
25  
36  
5
1
D5  
28  
1.5  
2
R or V  
Resistance (0-32kΩ) or Voltage (0-5V) programming  
1 Inhibit, Fixed Current Limit  
E5Hv  
Z19co  
HH5/3  
DD4  
EE4c  
HH5/4  
BB4  
EE5Lco  
C5B4  
EE5Ho  
CC5  
DD5  
24  
28  
24  
28  
3.5  
1
2 Inhibit, Programmable Current Limit (0-5V)  
3 Enable, Fixed Current Limit  
1, 2, 3  
or 4  
25.3  
28  
44.2b  
43s  
38  
18  
22.5  
4.5  
10  
18  
10  
18  
10  
15  
3
4 Enable, Programmable Current Limit (0-5V)  
28  
4
32.5  
32.6  
40  
53t  
1
Follow non wide range modules by F (Fast-on) or S (Screw) output terminals  
43q  
48  
2
4
Options - Single output Modules*  
Options - Twin output Modules*  
43  
48  
2
N
R
Output Inhibit, Module Good &  
Remote Sense  
Output Inhibit, Module Good &  
Current Sharing  
48  
56  
4
N
48.1  
42  
62r  
2
Remote Sense only  
56  
3
* see configuring guide  
a) F1, F2 and W2 modules not for Vega 900  
b)ꢀ38Vꢀmaxꢀforꢀ900W  
c) Only available for Vega 900  
d)ꢀ5.1Vꢀmaxꢀforꢀ900W  
e)ꢀ3.4Vꢀmaxꢀforꢀ900W  
f)ꢀ8Vꢀmaxꢀforꢀ900W  
h)ꢀ28Vꢀmaxꢀforꢀ900W  
i)ꢀ18Vꢀmaxꢀforꢀ900W  
j)ꢀ30Vꢀmaxꢀforꢀ900W  
k)ꢀ7.5Vꢀmaxꢀforꢀ900W  
l)ꢀ12.5Vꢀmaxꢀforꢀ900W  
m)ꢀ19Vꢀmaxꢀforꢀ900W  
n)ꢀ3.4Vꢀmaxꢀforꢀ900W  
o)ꢀ‘N’ꢀoptionꢀnotꢀavailable  
v)ꢀ‘N’ꢀoptionꢀnotꢀavailableꢀifꢀmore  
thanꢀ1ꢀmoduleꢀfitted  
w)ꢀ500mAꢀminꢀloadꢀbelowꢀ1V  
x)ꢀ100mAꢀminimumꢀloadꢀbelowꢀ2V  
p)ꢀ24Vꢀmaxꢀforꢀ900W  
q)ꢀ40Vꢀmaxꢀforꢀ900W  
r)ꢀ60Vꢀmaxꢀforꢀ900W  
s)ꢀ36Vꢀmaxꢀforꢀ900W  
t)ꢀ52Vꢀmaxꢀforꢀ900W  
u)ꢀ15.5Vꢀmaxꢀforꢀ900W  
g)ꢀ15Vꢀmaxꢀforꢀ900W  
Vega_Datasheet_69537 - v21.0  
Vega Series  
2
Isolation  
2 x MOPPs (3rd edition 60601) - units without xFW or xEW primary option fitted  
4kVac, 5.7kVdc type tested to 4kVac (equivalent to 5.7kVdc), production tested to 4.3kVdc.  
Input to Output  
Reinforced  
Basic  
Input to Earth  
1 x MOOP (3rd edition 60601) 2.3kVdc  
200Vdc  
Output to Output / Output to Earth  
Output Specification  
Voltage / Current  
Turn on time  
See output voltages table  
1.5s max  
<50ms  
at 90Vac (150Vac for 900W, 48Vdc for Vega dc) and 100% rated output power  
Rise time  
to 90% of voltage, monotonic rise above 10%  
Turn on overshoot  
Efficiency  
<5% or 250mV  
up to 75%  
16ms min  
<1% or 50mV  
<1%  
Load type dependent, no overshoot with resistive load  
at 230Vac (48Vdc for Vega dc) & 100% rated power, configuration dependent  
at 90Vac (150Vac for 900W) and 100% rated power (10ms min for Vega dc)  
pk-pk, using EIAJ test method & 20MHz bandwidth  
of set voltage  
Hold up  
Ripple and Noise  
Voltage Accuracy  
standard on single output modules, max 0.75V total line drop.  
Option for twin output modules  
Remote Sense  
Yes  
Minimum Load  
No  
<0.02%  
on any output (except W2 and W5 modules which need 0.5A load to achieve full specification)  
of rated voltage per °C  
Temperature Coefficient  
Load Regulation  
Line Regulation  
<0.5% or 50mV  
<0.1%  
for 0-100% load change  
for 90-264Vac input change (34 - 75Vdc for Vega dc)  
for 100% load change on any output  
Cross Regulation  
Transient Response  
Recovery  
<0.2%  
<6% or 300mV  
500µs  
of set voltage for 50% load change (above 25% load)  
for recovery to 1% or 100mV of set voltage  
Refer to application notes for details  
Over Voltage Protection  
Yes  
105-125%  
110-170%  
of rated current, constant current characteristic  
For EE2, EE4, EE5L, EE5H, Z2, Z18 and Z19 modules  
Over Current Protection (singles)  
Short Circuit Protection  
<150%  
Yes  
of rated current, when output voltage <1%  
shuts down all outputs and fan. Cycle ac off/on to reset  
Over Temperature Protection  
Shutdown temperature varies according to ambient, output power and input voltage.  
ac fail signal (if fitted) provides 5ms warning of thermal shutdown  
Environment  
Temperature  
0°C to 65°C operational, -40°C to 70°C storage (max 12 months).  
Derating  
50°C to 65°C derate total output power and each output current by 2.5% per °C  
Low Temp Startup  
Humidity  
-20°C  
5 - 95% RH non condensing  
±3 x 30g shocks in each plane, total 18 shocks  
30g shock = 11ms (+/-0.5msec), half sine  
Conforms to EN60068-2-27, EN60068-2-47, IEC68-2-27, IEC68-2-47, JIS C0041-1987.  
Conforms to MIL-STD-810E/F, Method 516.5, Pro I, IV, VI  
Shock  
Single axis 10 - 500 Hz at 2g (sweep and endurance at resonance) in all 3 planes  
Conforms to EN60068-2-6, IEC68-2-6  
Vibration  
Conforms to MIL-STD-810E, Method 514.4, Pro I, Cat 1, 9  
Altitude  
Pollution  
IP Rating  
5000 metres operational/non operational (IEC inlet 3000m operational, 5000m non operational)  
Degree 2, Material group IIIb  
IP 10  
Vega_Datasheet_69537 - v21.0  
3
Vega Series  
Emissions EN61000-6-3:2007, EN60601-1-2:2001  
(as per CISPR.11/22) Class B (Class A for Vega dc), FCC47 part 15 subpart B  
Radiated Electric Field  
EN55011, EN55032  
see application note for details. Additional filtering required for IEC inlet version.  
Only for ‘S’ type leakage variants.  
(as per CISPR.11/22) Class B (Class A for Vega dc), FCC47 part 15 subpart B  
Only for ‘S’ type leakage variants. ‘M’ and ‘L’ types meet Class A  
Conducted Emissions  
EN55011, EN55032  
Conducted Harmonics  
Flicker  
EN61000-3-2  
EN61000-3-3  
Class A - not applicable to Vega dc  
Compliant - dmax only - not applicable to Vega dc  
Immunity EN61000-6-2:2005, EN60601-1-2:2001  
Criteria  
Air discharge 15kV, Contact discharge 8kV  
12V/m  
A
Electrostatic Discharge  
EN61000-4-2  
Level 4  
Level 3  
Electromagnetic Field  
EN61000-4-3  
A
ac input tested to 4.4kV (2kV for Vega dc)  
dc output tested to 2.2kV (1kV for Vega dc)  
Tested at 5kHz and 100kHz  
Level 4  
Level 3 for Vega dc  
Fast / Burst Transient  
Surge Immunity  
EN61000-4-4  
EN61000-4-5  
A
A
Level 3  
Level 2 for Vega dc  
Common mode - 2.2kV (1.1kV for Vega dc)  
Differential - 1.1kV (0.55kV for Vega dc)  
12V  
Conducted RF Immunity  
EN61000-4-6  
EN61000-4-8  
Level 3  
Level 4  
A
A
30A/m  
Power Frequency Magnetic Field  
Voltage Dips, Variations, Interruptions EN61000-4-11  
Class 3  
A
na - Vega dc  
B for 5s interruptions  
Approvals / Accreditations  
IEC/EN 62368-1, UL62368-1 / CSA 22.2 No 62368-1  
File E135494  
File E135494  
IEC/EN 60950-1, UL60950-1 / CSA 22.2 No 60950-1  
IEC/EN 60601-1, UL/CSA 60601-1, ANSI/AAMI ES60601-1  
CAN/CSA-C22.2 No 60601-1-08  
File E349607 (not Vega dc, only for L, R and T leakage variants)  
IEC/EN 61010-1  
File E331788  
Low Voltage Directive (LVD), electromagnetic compatibility  
(EMC) and Restriction of Hazardous Substances (RoHS)  
CE Mark (EN62368-1)  
CB certificate and Report available on request  
Please check with technical sales for status of approvals  
Designed and manufactured under the control of ISO9001 and ISO13485 (including risk management).  
Vega_Datasheet_69537 - v21.0  
Vega Series  
4
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
Vega_Datasheet_69537 - v21.0  
5
Vega Series  
TDK-Lambda France SAS  
TDK-Lambda Americas  
Tel: +1 800-LAMBDA-4 or 1-800-526-2324  
powersolutions@us.tdk-lambda.com  
www.us.lambda.tdk.com  
Tel: +33 1 60 12 71 65  
france@fr.tdk-lambda.com  
www.emea.lambda.tdk.com/fr  
Italy Sales Office  
Tel: +39 02 61 29 38 63  
info.italia@it.tdk-lambda.com  
www.emea.lambda.tdk.com/it  
TDK Electronics do Brasil Ltda  
Tel: +55 11 3289-9599  
sales.br@tdk-electronics.tdk.com  
www.tdk-electronics.tdk.com/en  
Netherlands  
info@nl.tdk-lambda.com  
www.emea.lambda.tdk.com/nl  
TDK-Lambda Germany GmbH  
Tel: +49 7841 666 0  
info.germany@de.tdk-lambda.com  
TDK-Lambda Corporation  
Tel: +81-3-6778-1113  
www.jp.lambda.tdk.com  
www.emea.lambda.tdk.com/de  
TDK-Lambda (China) Electronics Co. Ltd.  
Tel: +86 21 6485-0777  
powersolutions@cn.tdk-lambda.com  
www.lambda.tdk.com.cn  
TDK-Lambda Singapore Pte Ltd.  
Tel: +65 6251 7211  
tls.mkt@sg.tdk-lambda.com  
www.sg.lambda.tdk.com  
Austria Sales Office  
Tel: +43 2256 655 84  
info@at.tdk-lambda.com  
www.emea.lambda.tdk.com/at  
TDK India Private Limited, Power Supply Division  
Switzerland Sales Office  
Tel: +41 44 850 53 53  
info@ch.tdk-lambda.com  
www.emea.lambda.tdk.com/ch  
Tel: +91 80 4039-0660  
mathew.philip@in.tdk-lambda.com  
www.sg.lambda.tdk.com  
Nordic Sales Office  
Tel: +45 8853 8086  
info@dk.tdk-lambda.com  
www.emea.lambda.tdk.com/dk  
TDK-Lambda UK Ltd.  
Tel: +44 (0) 12 71 85 66 66  
powersolutions@uk.tdk-lambda.com  
www.emea.lambda.tdk.com/uk  
TDK-Lambda Ltd.  
Tel: +9 723 902 4333  
info@tdk-lambda.co.il  
www.emea.lambda.tdk.com/il  
C.I.S.  
Commercial Support:  
Tel: +7 (495) 665 2627  
Technical Support:  
Tel: +7 (812) 658 0463  
info@tdk-lambda.ru  
www.emea.lambda.tdk.com/ru  
For additional information, please visit  
https://product.tdk.com/en/power  
Errorsꢀandꢀomissionsꢀexcepted  
Vega_Datasheet_69537 - v21.0  
Vega Series  
6

相关型号:

Vega900

AC-DC电源
TDK

VEH120

120Watts VEHSeries
XPPOWER

VEH120PS12

120Watts VEHSeries
XPPOWER

VEH120PS19

120Watts VEHSeries
XPPOWER

VEH120PS24

120Watts VEHSeries
XPPOWER

VEH150

150 Watts VEH Series
XPPOWER

VEH150PS12

150 Watts VEH Series
XPPOWER

VEH150PS19

150 Watts VEH Series
XPPOWER

VEH150PS24

150 Watts VEH Series
XPPOWER

VEH20

AC-DC Power Supplies
XPPOWER

VEH20/40-L6

AC-DC Power Supplies
XPPOWER

VEH20US05

Energy Efficiency Level V
XPPOWER