ZUP80-5-U [TDK]
Zero up programmable power supplies; 零了可编程电源型号: | ZUP80-5-U |
厂家: | TDK ELECTRONICS |
描述: | Zero up programmable power supplies |
文件: | 总2页 (文件大小:591K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
ZUP Series
Zero up programmable power supplies
Features
u Constant Voltage / Constant Current
u Last Setting Memory
u Digital Meters
u Built-in RS232 & RS485 Interface w/ GPIB optional
u Bench or Rack Mount
u Embedded Microprocessor Controller
u Voltage up to 120V, Current up to 132A
Key Market Segments & Applications
Specifications
Model
Load Regulation
Line Regulation
ZUP6
ZUP10
ZUP20
2mV + 0.005% over 0 - 100% load change
1mV + 0.005% over 85 - 132 or 170 - 265VAC line change
ZUP36
ZUP60
ZUP80
ZUP120
-
-
Recovery Time (1)
ms
-
1ms
0.5ms
0.2ms
30ppm/°C following 30 minute warm up
0.01% + 2mV change in output
50 - 60ms
Temperature Coefficient
Temperature Drift(2)
Up programming response time
Down prog. resp. time (CV)
Down prog. resp. time (CV)
Load Regulation
-
ms
ms
ms
-
-
-
-
-
80ms
120ms
800ms
50ms (70ms ZUP60-14)
250ms
350ms
400ms
500ms
750ms
600ms
0.01% + 5mA on 200W and 400W models, 0.07% + 10mA on 800W models
0.01% + 2mA on 200W and 400W models, 0.01% + 5mA on 800W models
100ppm/°C from rated current after 30 minute warm up time
0.02% + 5mA, 200W and 400W models, 0.05% + 10mA 800W models
Better than 0.028% of rated voltage
Line Regulation
Temperature Coefficient
Temperature Drift(2)
Prog Voltage resolution
Prog Voltage accuracy
Prog Current resolution
Prog Current accuracy
Overvoltage Shutdown
Thermal Protection
mV .02%+5mV .02%+8mV .02%+12mV .02%+20mV .02%+35mV .02%+50mV .02%+70mV
-
-
V
Better than 0.03% of rated voltage
0.4% + 40mA
0 - 7.5
0 - 13
0 - 24
0 - 40
0 - 66
0 - 88
0 - 132
-
Over temperature protected
Display - Voltage
Display - Current
Display - Status
Remote On/Off
-
-
-
-
3 digits (6, 20, 36, 60, 80V models), 3.5 digits (10, 120V models). Accuracy 0.2% ± 2 digits
3 digits, (3.5 digits 132A model). Accuracy 0.5% ± 3 digits
CV / CC, Alarm, Foldback, Local/Remote, On/Off
TTL signal or dry contact relay
Output Good
-
Open Collector
Voltage & Current Programming
Remote Sense
-
-
-
-
By either Voltage (0-4V) or Resistance (0-4k)
Up to 0.5V compensation per output cable
RS232 & RS485 standard, IEEE488 optional
Series: Up to two units; Parallel: Up to five units in master-slave configuration
85-265VAC (47-63Hz)
Communication Interface
Series & Parallel Operation
AC Input Voltage range
Inrush Current (100/200VAC)(3)
Hold Up Time (Typ) at 100VAC
Power Factor Correction
Temperature Range
Humidity (non condensing)
Cooling
VAC
A
ms
-
-
-
-
15/30A, 200W models, 15A, 400W models, 30A, 800W models
20
Complies with EN61000-3 Class A (0.99 typ)
Operating: 0 - 50°C; Storage: -20 to +70°C
Operating: 30 - 90% RH, Storage 10 - 95%RH
Internal fan
Withstand Voltage
-
-
-
-
-
Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
>100M at 25°C & 70%RH
Vibration:10-55Hz(1 min.) 2G constant X, Y, Z, when correctly mounted; Shock: <20G
UL3111-1, EN61010-1, CE Mark
Isolation Resistance
Vibration & Shock (non-op.)
Safety Agency Approvals
Conducted & Radiated EMI
Warranty
EN55022-B conducted,Aradiated, FCC Class B conducted,Aradiated, VCCI-2 conducted, -1 radiated
Three Years
yrs
Notes: (1) Recovery to within +/-50mV after load change of 50-100% (2) Over 8 hour period following 30 minute warm up time
(3) 25°C ambient (cold start)
1-800-526-2324 • www.us.tdk-lambda.com/lp/
152
Disclaimer: us.tdk-lambda.com/lp/legal.htm
ZUP Series
Model Selector
Voltage
Adjust
Current
Adjust
Range
Ripple
5Hz-1MHz
mV
Noise
20MHz BW
mV
Ripple
5Hz-1MHz
mA
Efficiency
%
(100/200VAC)
Max
Power
Weight
kg
Model
Range
ZUP6-33/U
ZUP6-66/U
ZUP6-132/U
ZUP10-20/U
ZUP10-40/U
ZUP10-80/U
ZUP20-10/U
ZUP20-20/U
ZUP20-40/U
ZUP36-6/U
ZUP36-12/U
ZUP36-24/U
ZUP60-3.5/U
ZUP60-7/U
ZUP60-14/U
ZUP80-2.5/U
ZUP80-5/U
ZUP120-1.8/U
ZUP120-3.6/U
0-6
0-33
0-66
0-132
0-20
0-40
0-80
0-10
0-20
0-40
0-6
198
396
792
200
400
800
200
400
800
216
432
864
210
420
840
200
400
216
432
5
5
50
50
100
50
50
90
50
50
80
50
50
70
50
50
60
80
80
80
80
50
100
200
25
50
100
15
30
60
7.5
15
30
5
69 / 72
74 / 77
74 / 77
73 / 77
79 / 82
77 / 81
74 / 78
79 / 83
79 / 82
76 / 80
80 / 84
80 / 84
75 / 79
80 / 84
80 / 84
77 / 82
83 / 87
77 / 82
83 / 87
2.9
3.2
5.8
2.9
3.2
5.8
2.9
3.2
5.8
2.9
3.2
5.8
2.9
3.2
5.8
2.9
3.2
2.9
3.2
0-6
0-6
8
0-10
0-10
0-10
0-20
0-20
0-20
0-36
0-36
0-36
0-60
0-60
0-60
0-80
0-80
0-120
0-120
5
5
8
5
5
5
5
0-12
0-24
0-3.5
0-7
5
5
5
5
10
20
5
0-14
0-2.5
0-5
5
30
30
30
30
10
5
0-1.8
0-3.6
10
Options & Accessories
Outline Drawing 200/400W
Option
Model Suffix Part Number
Front panel terminals (20A max)5 /L4
ZUP200/400/L4
ZUP800/L4
ZUP/U
Front panel terminals (20A max)6 /L4
IEC320 cable USA plug
Serial link cable RJ-45
GPIB Controller
/U
/W
ZUP/W
GP485A*
NL200*
Dual Unit Assembly
(accepts 200W or 400W models)
19” 3U rack (accepts up to 6 200/400W models) NL100*
Blanking panels for NL100 (19 in. rack)
RS232 Communications Cable DB-9
RS232 Communications Cable DB-25
RS485 Communications Cable DB-9
RS485 Communications Cable DB-25
User Manual
NL101*
ZUP/NC401
ZUP/NC403
ZUP/NC402
ZUP/NC404
NL102
* (See website for more details)
4 Not available with ZUP80 or ZUP120 models.
5 200W and 400W models
Outline Drawing 800W
6 800W models
For Additional Information, please visit
us.tdk-lambda.com/lp/products/zup.htm
Revision A6: May 2012
1-800-526-2324 • www.us.tdk-lambda.com/lp/
153