APPLIED POWER CONVERSION  
Division of  
TECHNOLOGY DYNAMICS INC.  
PTCP SERIES  
400-1000 WATT SINGLE OUTPUT  
SWITCHING POWER SUPPLIES  
2.66” x 4.75” x 11.50”  
“COTS” POWER FACTOR CORRECTED  
APPLICATIONS  
The PTCP series 400-1000W AC-DC power  
supplies provides highly regulated output power  
from 400-1000 watts.Rugged construction and  
superior quality make this power supply ideal  
for harsh environment applications. Available  
in standard, modified or fully custom  
configurations, for industrial, commercial,  
COTS, Ruggedized and Military applications.  
SPECIFICATIONS  
STANDARD FEATURES  
.98 Typical Power Factor  
Full Range  
Low Noise and Ripple  
Built In DC Fan For Cooling  
Current Share Function  
DC Good Signal  
Remote On/Off & Remote Sense Functions  
Rugged Construction  
High Reliability/Superior Quality  
INPUT SPECIFICATIONS:  
Input: 100-264 VAC Single Phase  
Input Frequency: 47-63Hz (400 Hz Optional)  
Inrush Current: 60A max at 230VAC(cold start)  
Input Current: 6.5A max @ 115VAC 3.5A max @ 230VAC  
Efficiency: 85 typical (depending on output model)  
Hold-up time: 16ms at full load (minimum)  
Leakage Current: <3.5mA maximum @ 240 VAC  
OUTPUT SPECIFICATIONS  
Adjustment Range: ±10% (minimum)  
Minimum Load: none  
AVAILABLE OPTIONS  
Hot Swap  
Regulation: Line ±0.5% Load ±0.5% Typical  
Ripple/Noise: 150mV peak to peak maximum (20 MHz)  
Set Point Accuracy: ±1%(except 5V=±2%) (maximum)  
Output voltage adj: ±10% minimum  
Overcurrent Protection: 105-125% automatic recovery Constant Current  
Overlvoltage Protection: 115-140% of V1 nominal  
Overtemperature Protection: Heatsink Temp. 90°C ± 5°C Auto Recovery  
Parallel Operation  
ORing Diode for Redundant Operation  
Rack / Panel Mount  
Ruggedized for shock & vibration  
400Hz Operation  
Conformal Coating  
ENVIRONMENTAL SPECIFICATIONS  
Operating Temperature: 0°C to +50°C. Derate to 50% at +70°C  
Storage Temperature: -40°C to +85°C max 95% Relative Humidity  
Cooling: Internal ball bearing DC fan  
LVBD (Battery Back-Up)  
SAFETY AND EMISSIONS  
Designed to meet UL/cUL60950-1  
Humidity: 20-90% RH non condensing  
Designed to meet TUV EN60950-1  
Designed to meet EN55022 (Class A)  
Designed to meet EN 55024  
Vibration: 10-500Hz, 2G 10min/1cycle for 60 min (3 axes)(Standard Unit)  
Shock: 20G Peak Acceleration (Standard Unit)  
Weight: Approx: 6.6 LBS  
Size: 2.66” x 4.75” x 11.50”  
Designed to meet EN61000-3-2-3  
Design Excellence since 1976!  
File: A5269  
MODEL SELECTION  
800 WATTS  
400 WATTS  
600 WATTS  
1000 WATTS  
Model  
Output  
Model  
Model  
Output  
Model  
Output  
Output  
3.5/5V@80A  
12V@34A  
15V@27A  
24V@17A  
28V@14A  
36V@11A  
48V@8A  
N/A  
PTCP - 5 - 80  
PTCP - 12 - 34  
PTCP - 15 - 27  
5V@100A  
12V@50A  
N/A  
PTCP-5-100  
PTCP - 12 - 50  
PTCP - 15 - 40  
PTCP - 24 - 25  
PTCP - 28 - 20  
PTCP - 36 -16  
PTCP - 48 - 12  
Consult  
Factory  
12V@66A  
PTCP - 12 - 66  
PTCP - 15 - 53  
PTCP - 24 - 33  
PTCP - 28 - 28  
PTCP - 36 - 22  
PTCP - 48 - 16  
15V@53A  
24V@33A  
28V@28A  
15V@40A  
24V@25A  
28V@20A  
PTCP - 24 - 17  
PTCP - 28 - 14  
PTCP - 36 - 11  
PTCP - 48 - 8  
PTCP - 24 - 41  
24V@41A  
28V@35A  
36V@27A  
48V@20A  
PTCP - 28 - 35  
PTCP - 36 - 27  
PTCP - 48 - 20  
36V@22A  
48V@16A  
36V@16A  
48V@12A  
OPTION DESIGNATIONS  
-WTO  
-HSP  
-ORD  
-RK  
WIDE TEMPERATURE OPERATION  
HOT SWAP  
Low Voltage Battery Disconnect  
REDUNDANT OPERATION (ORING DIODE)  
RACK MOUNT  
The LVBD module adds a new dimension to battery backup power  
supplies. The power supply simultaneously charges the battery and  
powers the load. If the AC power fails, the battery continues to  
support the load. However, when the battery voltage drops below a  
predetermined level, the LVBD module disconnects the battery from  
the load, thereby protecting the battery from the damaging effects of  
complete discharge.  
-MIL  
RUGGEDIZED/MILITARIZED  
CONFORMAL COATING  
BATTERY BACK-UP  
-CC  
-LVBD  
-PAR  
-PNL  
PARALLEL OPERATION  
PANEL MOUNT  
-400HZ  
400 Hz OPPERATION  
MECHANICAL OUTLINE  
APPLIED POWER CONVERSION  
division of  
TECHNOLOGY DYNAMICS INC.  
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE  
100 School Street, Bergenfield, NJ 07621  
Phone: (201) 385-0500, Fax: (201) 385-0702  
Website: www.theallpower.com  

相关型号:

PTCP-36-16

SWITCHING POWER SUPPLIES
TECHNOLOGY

PTCP-36-22

SWITCHING POWER SUPPLIES
TECHNOLOGY

PTCP-36-27

SWITCHING POWER SUPPLIES
TECHNOLOGY

PTCP-48-12

SWITCHING POWER SUPPLIES
TECHNOLOGY

PTCP-48-16

SWITCHING POWER SUPPLIES
TECHNOLOGY

PTCP-48-20

SWITCHING POWER SUPPLIES
TECHNOLOGY

PTCP-48-8

SWITCHING POWER SUPPLIES
TECHNOLOGY

PTCP-5-100

SWITCHING POWER SUPPLIES
TECHNOLOGY

PTCP-5-80

SWITCHING POWER SUPPLIES
TECHNOLOGY

PTCP-HS-12-102

HOT SWAP POWER SYSTEMS
TECHNOLOGY

PTCP-HS-12-150

HOT SWAP POWER SYSTEMS
TECHNOLOGY

PTCP-HS-15-120

HOT SWAP POWER SYSTEMS
TECHNOLOGY