2380J-120-60 [TEKTRONIX]
Programmable DC Electronic Loads;型号: | 2380J-120-60 |
厂家: | TEKTRONIX, INC. |
描述: | Programmable DC Electronic Loads |
文件: | 总5页 (文件大小:544K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Series 2380
Programmable DC Electronic Loads
Series 2380 programmable DC
electronic loads can sink a wide range
of voltages and currents. The 200W
Model 2380-500-15 can accept up
to 500V or 15A. The 250W Model
2380-120-60 can accept up to 120V
or 60A. The 750W Model 2380- 500
30 can accept up to 500V or 30A.
These single-output, stand-alone
electronic loads are cost-effective and
self-contained.
Multiple Operating Modes
These DC electronic loads can operate
in constant current (CC), constant
voltage (CV), constant resistance (CR),
or constant power (CP) mode. They
can also be configured to provide
a dynamically changing load to the
DC source with load switching times
as fast as 25kHz. Versatile internal, external, and remote triggering options allow
synchronizing the dynamic load behavior with other events.
• 200W, 250W, and 750W models
• Supports up to 500V or 60A
Comprehensive Protection
• Constant current (CC),constant
voltage (CV), constant resistance
(CR), and constant power (CP)
operating modes
Protection functions built into Series 2380 DC electronic loads ensure the reliability
and safety of all tests. These functions include over temperature protection (OTP),
over voltage protection (OVP), over current protection (OCP), over power protection
(OPP), and local/remote reverse voltage (LRV/RRV) protection. A power-on system
self-test ensures the instrument is operating properly.
• LED simulated load test mode
• Readback voltage and current
resolution down to 0.1mV/0.01mA
Full Complement of Settings and Controls
To maximize testing efficiency, you can save test parameters into any one of
100 memory locations for quick recall. All load parameters, such as voltage,
current, slew rate, and dynamic mode time intervals, can be set using the front
panel controls or programmed remotely. A numeric keypad and rotary knob
allow entering settings quickly and setting parameters to their full resolution
easily. USB-TMC, GPIB and RS-232 interfaces are built in for remote control and
communication. A current monitor interface simplifies monitoring input current
waveforms by providing a connection for an oscilloscope.
• Dynamic mode with cycle rate up
to 25kHz
• Voltage rise and fall time
measurement
• Current monitor function
• List mode
• Battery test mode
• Built-in GPIB,USB, and RS-232
interfaces
Figure 1. Use either the rotary knob or the keypad to quickly enter settings and set parameter values using all the
available resolution.
A Tektronix Company
2380
Programmable DC Electronic Loads
Ordering Information
2380-500-15
Programmable DC
Electronic Load,
500V, 15A, 200W
2380-120-60
Programmable DC
Electronic Load,
120V, 60A, 250W
Model 2380-500-15 rear panel
Model 2380-500-15 front view showing the safety
covers on the input terminals.
2380-500-30
Programmable DC
Electronic Load,
500V, 30A, 750W
2380J-500-15
Programmable DC
Electronic Load, 500V,
15A, 200W-Japan only
2380J-120-60
Programmable DC
Electronic Load, 120V,
60A, 250W-Japan only
2380J-500-30
Programmable DC
Electronic Load, 500V,
30A, 750W-Japan only
Model 2380-500-30 rear panel
ACCESSORIES AVAILABLE
SERVICES AVAILABLE
Model Number*-1-EW
2380-001
2380-002
7007-2
9-pin Rear Panel Mating Connector
Accessories Supplied
Quick Start Guide
Documentation CD
Power cord
3-year factory warranty from date of shipment
extended 1 additional year
DUT Connection Protective Cover
Double-Shielded Premium IEEE-488 Interface
Cable, 2m (6.5 ft)
Model Number*-5Y-EW
3-year factory warranty from date of shipment
extended to 5 years
KP-CL-488LPA IEEE-488.2 Interface Board for the PCI Bus
C/Model Number*-3Y-STD
USB-B-1
USB Cable, Type A Connector to Type B
Connector, 1m (3.3 ft)
KeithleyCare 3 YR STD Calibration Plan
C/Model Number*-3Y-DAT
RACK MOUNT KITS FOR THE 2380-500-15 AND
THE 2380-120-60
KeithleyCare 3 YR Calibration w/Data Plan
APPLICATIONS
C/Model Number*-5Y-STD
4299-7
RMU2U
Universal Fixed Rack Mount Kit
Fixed Rack Mount Kit
KeithleyCare 5 YR STD Calibration Plan
• Environmental test, stress test,
and accelerated life testing
for AC/DC power sources and
DC/DC modules
C/Model Number*-5Y-DAT
386759800 RMU2U Rack Mount Cosmetic Filler Panel
KeithleyCare 5 YR Calibration w/Data Plan
* Replace the specific power supply model number in place
of Model Number to generate the appropriate model
number for a service item. Example for a 2380-500-15,
a 1-year extended warranty model number would be
2380-500-15-EW.
RACK MOUNT KIT FOR THE 2380-500-30
2380-RM
Full-Rack-Width Instrument Fixed
Rack Mount Kit
• LED lighting drivers and high
power component testing
• Automotive electronics testing
• Battery research and discharge
testing
• Production test
A Tektronix Company
2380
Programmable DC Electronic Loads
Specifications
Model 2380-500-15/2380J-500-15
Model 2380-120-60/2380J-120-60
Low Range
0–500 V
0–3 A
200 W
High Range
0–500 V
0–15 A
Low Range
0–120 V
0–6 A
High Range
0–120 V
0–60 A
Input Voltage
Input Current
Input Power
Min. Operating
Voltage
Input Voltage
Input Current
Input Power
Min. Operating
Voltage
Rated Value
(0°–40°C)
Rated Value
(0°–40°C)
200 W
250 W
250 W
0.6 V at 3 A (maximum 0.9 V)
4.5 V at 15 A
0.18 V at 6 A
1.8 V at 60 A
Range
0.1–50 V
1 mV
(0.05ꢀ ꢁ 0.025ꢀ FS)
0–3 A
0.1– 500 V
10 mV
(0.05ꢀ ꢁ 0.025ꢀ FS)
0–15 A
Range
0–18 V
1 mV
(0.05ꢀ ꢁ 0.025ꢀ FS)
0–6 A
0–120 V
10 mV
(0.05ꢀ ꢁ 0.025ꢀ FS)
0–60 A
Constant Voltage
Mode
Constant Voltage
Mode
Resolution
Accuracy
Range
Resolution
Accuracy
Range
Resolution
Accuracy 2
Range
Resolution
Accuracy
Resolution
Accuracy
Range
Resolution
Accuracy
Range
Resolution
Accuracy 2
Range
Resolution
Accuracy
Constant Current
Mode
0.1 mA
1 mA
0.1 mA
1 mA
Constant Current
Mode
(0.05ꢀ ꢁ 0.05ꢀ FS)
0.3 Ω–10 Ω
0.001 Ω
0.01ꢀ ꢁ 0.08 S
200 W
(0.05ꢀ ꢁ 0.05ꢀ FS)
10 Ω–7.5 kΩ
0.1 Ω
0.01ꢀ ꢁ 0.0008 S
200 W
(0.05ꢀ ꢁ 0.1ꢀ FS)
0.05 Ω–10 Ω
0.001 Ω
0.01ꢀ ꢁ 0.08 S
250 W
(0.05ꢀ ꢁ 0.1ꢀ FS)
10 Ω–7.5 kΩ
0.1 Ω
0.01ꢀ ꢁ 0.0008 S
250 W
Constant
Constant
Resistance Mode 1
Resistance Mode 1
Constant Power
Mode 3
Constant Power
Mode 3
10 mW
0.1ꢀ ꢁ 0.1ꢀ FS
10 mW
0.1ꢀ ꢁ 0.1ꢀ FS
10 mW
0.2ꢀ ꢁ 0.2ꢀ FS
10 mW
0.2ꢀ ꢁ 0.2ꢀ FS
Dynamic Mode
Dynamic Mode
T1 & T2
20 µs–3600 s; Res: 1 µs
5 µs 100 ppm
20 µs–3600 s; Res: 1 µs
5 µs 100 ppm
T1 & T2
20 µs–3600 s; Res: 1 µs
5 µs 100 ppm
20 µs–3600 s; Res: 1 µs
5 µs 100 ppm
Accuracy
Ascending/
Descending
Slope 4
Accuracy
Ascending/
Descending
Slope 4
CC Mode
CC Mode
0.0001–0.1 A/µs
~10 µs
0.001–1 A/µs
~10 µs
0.0001–0.25 A/µs
~20 µs
0.001–2.5 A/µs
~20 µs
Minimum Rise
Minimum Rise
Time 5
Time 5
Measuring Range
Measuring Range
Range
0–50 V
1 mV
0–500 V
10 mV
Range
0–18 V
0.1 mV
0–120 V
1 mV
Readback Voltage Resolution
Readback Voltage Resolution
Accuracy
(0.025ꢀ ꢁ 0.025ꢀ FS)
0–3 A
0.01 mA
(0.05ꢀ ꢁ 0.05ꢀ FS)
200 W
(0.025ꢀ ꢁ 0.025ꢀ FS)
0–15 A
0.1 mA
(0.05ꢀ ꢁ 0.05ꢀ FS)
200 W
Accuracy
(0.025ꢀ ꢁ 0.025ꢀ FS)
0–6 A
0.1 mA
(0.05ꢀ ꢁ 0.1ꢀ FS)
250 W
(0.025ꢀ ꢁ 0.025ꢀ FS)
0–60 A
1 mA
(0.05ꢀ ꢁ 0.1ꢀ FS)
250 W
Range
Readback Current Resolution
Accuracy
Range
Readback Current Resolution
Accuracy
Range
Range
Readback Power Resolution
Accuracy
10 mW
(0.1ꢀ ꢁ 0.1ꢀ FS)
10 mW
(0.1ꢀ ꢁ 0.1ꢀ FS)
Readback Power
Resolution
Accuracy
10m W
(0.2ꢀ ꢁ 0.2ꢀ FS)
10m W
(0.2ꢀ ꢁ 0.2ꢀ FS)
Protection Range
Protection Range
Overpower Protection
Overcurrent Protection
Overvoltage Protection
Over Temperature Protection
~210 W
~3.3 A
~530 V
~85°C
~210 W
~16.5 A
~530 V
~85°C
Overpower Protection
~260 W
~6.6 A
~130 V
~85°C
~260 W
~66 A
~130 V
~85°C
Overcurrent Protection
Overvoltage Protection
Over Temperature Protection
Specification
Specification
Current (CC)
Voltage (CV)
~3.3 / 3 A
~0 V
~16.5 / 15 A
~0 V
Current (CC)
Voltage (CV)
~6.6 / 6 A
0 V
~66 / 60 A
0 V
Short Circuit
Short Circuit
Resistance (CR)
Input Terminal Impedance
Dimensions
~300 mΩ
~1 MΩ
214.81mm × 104.24mm × 397.03mm
~300 mΩ
~1 MΩ
Resistance (CR)
Input Terminal Impedance
Dimensions
~30 mΩ
~300 kΩ
~30 mΩ
~300 kΩ
214.81mm ×104.24mm × 397.03mm
NOTES*
1. The voltage/current input is no less than 10ꢀ FS (FS indicates the full scale). Accuracy is defined as: ꢀ of reading ꢁ ꢀ of full scale.
2. The range of read-back resistance is between (1/(1/R ꢁ (1/R)*0.01ꢀ ꢁ 0.08)Ω and 1/(1/R–(1/R)*0.01ꢀ–0.08))Ω.
3. The voltage/current input is no less than 10ꢀ FS.
4. Ascending/descending slope: 10ꢀ–90ꢀ current ascending slope from 0 to maximum current.
5. Minimum rise time: 10ꢀ–90ꢀ current rise time.
*Specifications are subject to change without notice.
A Tektronix Company
2380
Programmable DC Electronic Loads
Model 2380-500-30/2380J-500-30
General
Low Range
High Range
0–500 V
0–30 A
750 W
Memory Capacity: 100 sets of measurements and selectable parameters.
Input Voltage
Input Current
Input Power
Min. Operating
Voltage
0–500 V
Signal Connections:
0–3 A
750 W
Rated Value
(0°–40°C)
Front Panel: Input: Stud and threaded knob terminals for lug connectors (200W and
250W versions).
Rear Panel:
0.36 V / 3 A
3.6 V / 30 A
Input: Terrminal Bars (750W version).
Current Monitor Output: BNC.
Remote Sense, Analog Input, External Trigger, Voltage Fault: 9-pin
terminal block.
Range
0–50 V
1 mV
0–500 V
10 mV
(0.025ꢀ ꢁ 0.05ꢀ FS)
0–30 A
Constant Voltage
Mode
Resolution
Accuracy
Range
Resolution
Accuracy
Range
Resolution
Accuracy 2
Range
Resolution
Accuracy
(0.025ꢀ ꢁ 0.05ꢀ FS)
0–3 A
Constant Current
Mode
Communications:
0.1 mA
1 mA
USB: USB2.0 device, type B, USB-TMC compliant.
RS-232: DB-9 connector.
(0.05ꢀ ꢁ 0.05ꢀ FS)
0.15 Ω–10 Ω
0.001 Ω
0.01ꢀ ꢁ 0.08 S
750 W
(0.05ꢀ ꢁ 0.05ꢀ FS)
10 Ω–7.5 kΩ
0.1Ω
0.01ꢀ ꢁ 0.0008 S
750 W
Constant
GPIB: IEEE-488.2 compliant.
Cooling Method: Fan.
Fan Speed vs. Internal temperature:
Resistance Mode 1
Constant Power
Mode 3
10 mW
10 mW
0.2ꢀ ꢁ 0.2ꢀ FS
Temperature
40°C
50°C
70°C
85°C
0.2ꢀ ꢁ 0.2ꢀ FS
Temperature protection (OH)
and load is shut off.
Fan status
First gear
Second gear Third gear
Dynamic Mode
T1 & T2
20 µs–3600 s; Res: 1 µs
5 µs 100 ppm
20 µs–3600 s; Res: 1 µs
5 µs 100 ppm
Power Source:
Accuracy
Ascending/
Descending
Slope 4
AC Input: Switchable between 120VAC nominal and 240VAC nominal.
“J” versions: 100VAC, nominal.
Frequency: 50/60Hz.
Power Consumption:
2380-500-15: 40VA.
CC Mode
0.0001–0.1 A/µs
~20 µs
0.001–1 A/µs
~20 µs
Minimum Rise
Time 5
2380-120-60: 40VA.
2380-500-30: 150VA.
EMC: Conforms to European Union EMC Directive.
Measuring Range
Range
0–50 V
1 mV
0–500 V
10 mV
Readback Voltage Resolution
Accuracy
(0.025ꢀ ꢁ 0.025ꢀ FS)
0–3 A
0.1 mA
(0.05ꢀ ꢁ 0.05ꢀ FS)
750 W
(0.025ꢀ ꢁ 0.025ꢀ FS)
0–30 A
1 mA
(0.05ꢀ ꢁ 0.05ꢀ FS)
750 W
Safety:
Range
Readback Current Resolution
Accuracy
Canadian Certification: CSA listed to UL Std. No. 61010-1(3rd Edition) and Can/CSA-
C22.2 No. 61010-1-12.
European Union Compliance: Conforms to European Union Low Voltage Directive.
Environment:
Altitude: Operating: 2000m, (6562 ft) above sea level.
Temperature and Relative Humidity:
Range
Resolution
Accuracy
Readback Power
10 mW
(0.2ꢀ ꢁ 0.2ꢀ FS)
10 mW
(0.2ꢀ ꢁ 0.2ꢀ FS)
Protection Range
Overpower Protection
Overcurrent Protection
Overvoltage Protection
Over Temperature Protection
Operating: 0° to 40°C full accuracy with 80ꢀ relative humidity at up to 35°C, non-
condensing.
Storage: –20° to 70°C, 10ꢀ to 85ꢀ relative humidity up to 40°C, 5ꢀ to 60ꢀ relative
humidity above 40°C.
~760 W
~3.3 A
~530 V
~85°C
~760 W
~33 A
~530 V
~85°C
Net Weight:
200W/250W Model: 4.65kg.
750W Model: 24.95kg.
Shipping Weight:
Specification
Current (CC)
Voltage (CV)
~3.3 / 3 A
0 V
~3.3 / 30 A
0 V
Short Circuit
200W/250W Model: 7kg.
750W Model: 31.75kg.
Recommended calibration frequency: 1 time/year.
Warranty: 3 years.
Resistance (CR)
Input Terminal Impedance
Dimensions
~120 mΩ
1 MΩ
~120 mΩ
1 MΩ
482mm × 131.4mm × 580mm
NOTES*
1. The voltage/current input is no less than 10ꢀ FS (FS indicates the full scale).
Accuracy is defined as: ꢀ of reading ꢁ ꢀ of full scale.
2. The range of read-back resistance is between (1/(1/R ꢁ (1/R)*0.01ꢀ ꢁ 0.08)Ω and 1/(1/R–(1/R)*0.01ꢀ–0.08))Ω.
3. The voltage/current input is no less than 10ꢀ FS.
4. Ascending/descending slope: 10ꢀ–90ꢀ current ascending slope from 0 to maximum current.
5. Minimum rise time: 10ꢀ–90ꢀ current rise time.
*Specifications are subject to change without notice.
A Tektronix Company
Contact Information:
ASEAN / Australia (65) 6356 3900
Austria 00800 2255 4835
Balkans, Israel, South Africa and other ISE Countries +41 52 675 3777
Belgium 00800 2255 4835
Brazil +55 (11) 3759 7627
Canada 1 800 833 9200
Central East Europe and the Baltics +41 52 675 3777
Central Europe & Greece +41 52 675 3777
Denmark +45 80 88 1401
Finland +41 52 675 3777
France 00800 2255 4835
Germany 00800 2255 4835
Hong Kong 400 820 5835
India 000 800 650 1835
Italy 00800 2255 4835
Japan 81 (3) 6714 3010
Luxembourg +41 52 675 3777
Mexico, Central/South America & Caribbean 52 (55) 56 04 50 90
Middle East, Asia, and North Africa +41 52 675 3777
The Netherlands 00800 2255 4835
Norway 800 16098
People’s Republic of China 400 820 5835
Poland +41 52 675 3777
Portugal 80 08 12370
Republic of Korea 001 800 8255 2835
Russia & CIS +7 (495) 6647564
South Africa +41 52 675 3777
Spain 00800 2255 4835
Sweden 00800 2255 4835
Switzerland 00800 2255 4835
Taiwan 886 (2) 2656 6688
United Kingdom & Ireland 00800 2255 4835
USA 1 800 833 9200
Rev 0415
For Further Information
Tektronix maintains a comprehensive,
constantly expanding collection of
application notes, technical briefs and
other resources to help engineers working
on the cutting edge of technology.Visit
www.tektronix.com or www.keithley.com.
Copyright © 2015, Tektronix. All rights
reserved. Tektronix products are covered
by U.S. and foreign patents, issued and
pending. Information in this publication
supersedes that in all previously published
material. Specification and price change
privileges reserved. TEKTRONIX and TEK
are registered trademarks of Tektronix, Inc.
All other trade names referenced are the
service marks, trademarks or registered
trademarks of their respective companies.
121715.KI
1KW-60327-0
A Tektronix Company
相关型号:
©2020 ICPDF网 联系我们和版权申明