MDO3SEC [TEKTRONIX]
Mixed Domain Oscilloscopes;型号: | MDO3SEC |
厂家: | TEKTRONIX, INC. |
描述: | Mixed Domain Oscilloscopes |
文件: | 总40页 (文件大小:2527K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Mixed Domain Oscilloscopes
MDO3000 Series Datasheet
Key performance specifications
1. Oscilloscope
2 and 4 analog channel models
1 GHz, 500 MHz, 350 MHz, 200 MHz, 100 MHz bandwidth models
Bandwidth is upgradable (up to 1 GHz)
Up to 5 GS/s sample rate
10 M record length on all channels
>280,000 wfm/s maximum waveform capture rate
Standard passive voltage probes with 3.9 pF capacitive loading
and 1 GHz, 500 MHz, or 250 MHz analog bandwidth
2. Spectrum Analyzer
Frequency range
Standard: 9 kHz - oscilloscope bandwidth
Optional: 9 kHz - 3 GHz
The ultimate 6-in-1 integrated oscilloscope, completely
customizable and fully upgradeable
Ultra-wide capture bandwidth up to 3 GHz
Today's integrated designs need an oscilloscope that is just as integrated -
such as the MDO3000 Mixed Domain Oscilloscope (MDO) Series. It is the
ultimate 6-in-1 integrated oscilloscope that includes an integrated spectrum
analyzer, arbitrary function generator, logic analyzer, protocol analyzer, and
digital voltmeter/counter. The MDO3000 is completely customizable and
fully upgradeable. Add the instruments and performance you need now - or
later.
3. Arbitrary Function Generator (Optional)
13 predefined waveform types
50 MHz waveform generation
128 k arbitrary generator record length
250 MS/s arbitrary generator sample rate
4. Logic Analyzer (Optional)
16 digital channels
10 M record length on all channels
121.2 ps timing resolution
5. Protocol Analyzer (Optional)
Serial bus support for I2C, SPI, RS-232/422/485/UART, USB 2.0,
CAN, CAN FD, LIN, FlexRay, MIL-STD-1553, ARINC-429, and
Audio standards
Digital Voltmeter / Frequency Counter (Free with product registration)
4-digit AC RMS, DC, and AC+DC RMS voltage measurements
5-digit frequency measurements
www.tek.com
1
Datasheet
2 www.tek.com
Mixed Domain Oscilloscopes -- MDO3000 Series
www.tek.com
3
Datasheet
Typical applications
Manufacturing Test and Troubleshooting
Embedded design
Size and space constraints can play havoc on a manufacturing floor.
The unique 6-in-1 MDO3000 minimizes rack or bench space by
integrating multiple instruments into one small package. Integration
reduces cost associated with utilizing multiple different instrument types
in manufacturing test or troubleshooting stations.
Discover and solve issues quickly by performing system level debug on
mixed signal embedded systems including today's most common serial
bus technologies with the 6-in-1 MDO3000 and support for a broad set
of common serial buses.
Service Installation and Maintenance
Power design
Having the right instruments when and where you need them is critical.
The MDO3000 includes six instrument types in a light weight (9.2 lb.,
4.2 kg), portable package - making it the perfect choice where space is
limited and flexibility is desired.
Make reliable and repeatable voltage, current, and power
measurements using automated power quality, switching loss,
harmonics, ripple, modulation, and safe operating area measurements
with the widest selection of power probes in an affordable solution.
Education
Need more performance?
Managing multiple instruments on a bench can be troublesome. The
MDO3000 eliminates the need to manage multiple instruments by
integrating six instrument types into a single, small (5.8 in., 147.4 mm
deep) instrument. The combination of a small instrument and high level
of integration aids in the teaching of various electronics principles as
well as in its usage for more sophisticated lab experiments. Full
upgradeability enables adding functionality over time as needs change
or budgets allow.
MSO/DPO2000B
MDO3000
MDO4000C
MSO/DPO5000B
High-level description
Commonly used for
Advanced Debug Features at an Integrated Oscilloscope with Six Synchronized Insights into
Exceptional Signal Fidelity with
Advanced Analysis and Math
Affordable Price
Instruments in One
Analog, Digital and RF Signals
Design and Debug
Education
Design and Debug
EMI Troubleshooting
Education
Design and Debug
Advanced Design and Debug
USB Ethernet Compliance
Research
EMI Troubleshooting
General Purpose RF Design
and Integration
Analog Bandwidth
70 MHz, 100 MHz, 200 MHz
100 MHz, 200 MHz, 350 MHz,
500 MHz,
1 GHz
200 MHz, 350 MHz, 500 MHz,
1 GHz
350 MHz, 500 MHz, 1 GHz,
2 GHz
Maximum Analog Sample Rate 1 GS/s
5 GS/s
2, 4
5 GS/s
4
10 GS/s
Analog Channels
2, 4
4
Record Length
1 M
10 M
20 M
16
25 M (Optional) Up to 125 M
Digital Channels
(Optional) 16
N/A
(Optional) 16
(Optional) 16
N/A
Spectrum Analyzer Channel
(Standard) 9 kHz - Analog BW
(Optional) 9 kHz - 3 GHz
(Optional) 9 kHz - 3 GHz
(Optional) 9 kHz - 6 GHz
AFG
N/A
Up to 50 MHz with 13 functions N/A
and arbitrary waveform
generation
N/A
4 www.tek.com
Mixed Domain Oscilloscopes -- MDO3000 Series
MSO/DPO2000B
MDO3000
MDO4000C
MSO/DPO5000B
Serial Bus Analysis
Trigger & Decode: I 2 C, SPI,
RS-232/422/485/UART, CAN,
LIN
Trigger & Decode: I 2 C, SPI,
RS-232/422/485/UART, CAN,
CAN FD, LIN, FlexRay, USB2.0, CAN FD, LIN, FlexRay, USB2.0, LIN, FlexRay, USB2.0, Ethernet,
Trigger & Decode: I 2 C, SPI,
RS-232/422/485/UART, CAN,
Trigger & Decode: I 2 C, SPI,
RS-232/422/485/UART, CAN,
MIL-STD-1553, ARINC-429,
Audio
MIL-STD-1553, ARINC-429,
Audio
MIL-STD-1553
Decode Only: USB-HSIC, MIPI
D-PHY
Compliance: BroadR-Reach,
USB2.0, USB-PWR, Ethernet,
MOST
Advanced Analysis
Standard Probing
Power, Limit/Mask, Video
Power, Limit/Mask, Video,
Spectrogram, Vecto signal
analysis
Power, Limit/Mask, Video, Vector
signal analysis, Jitter
100 MHz, 12 pF
or
200 MHz, 12 pF
200 MHz, 3.9 pF
500 MHz, 3.9 pF
or
200 MHz, 3.9 pF
500 MHz, 3.9 pF
or
500 MHz, 3.9 pF
or
1 GHz, 3.9 pF
1 GHz, 3.9 pF
1 GHz, 3.9 pF
1 – Oscilloscope
The Normal palette uses the default channel color (like yellow for
channel one) along with gray-scale to indicate frequency of occurrence
where frequently occurring events are bright.
At the core of the MDO3000 Series is a world-class oscilloscope, offering
comprehensive tools that speed each stage of debug – from quickly
discovering anomalies and capturing them, to searching your waveform
record for events of interest and analyzing their characteristics and your
device’s behavior.
The Inverted palette uses the default channel color along with gray-
scale to indicate frequency of occurrence where rarely occurring events
are bright.
These color palettes quickly highlight the events that over time occur more
often or, in the case of infrequent anomalies, occur less often.
®
Digital phosphor technology with FastAcq high-
speed waveform capture
Infinite or variable persistence choices determine how long waveforms stay
on the display, helping you to determine how often an anomaly is occurring.
To debug a design problem, first you must know it exists. Every design
engineer spends time looking for problems in their design, a time-
consuming and frustrating task without the right debug tools.
Digital phosphor technology provides you with fast insight into the real
operation of your device. Its fast waveform capture rate – greater than
280,000 wfms/s with FastAcq – gives you a high probability of quickly
seeing the infrequent problems common in digital systems: runt pulses,
glitches, timing issues, and more.
To further enhance the visibility of rarely occurring events, intensity grading
is used to indicate how often rare transients are occurring relative to normal
signal characteristics. There are four waveform palettes available in
FastAcq acquisition mode.
The Temperature palette uses color-grading to indicate frequency of
occurrence with hot colors like red/yellow indicating frequently
occurring events and colder colors like blue/green indicating rarely
occurring events.
Digital phosphor technology with FastAcq enables greater than 280,000 wfms/s
waveform capture rate and real-time color-intensity grading.
The Spectral palette uses color-grading to indicate frequency of
occurrence with colder colors like blue indicating frequently occurring
events and hot colors like red indicating rarely occurring events.
www.tek.com
5
Datasheet
Triggering
Zoom and pan
Discovering a device fault is only the first step. Next, you must capture the
event of interest to identify root cause. To enable this, the MDO3000
contains over 125 trigger combinations providing a complete set of triggers
- including runt, logic, pulse width/glitch, setup and hold violation, serial
packet, and parallel data - to help quickly locate your event of interest. And
with up to a 10 M record length, you can capture many events of interest,
even thousands of serial packets, in a single acquisition for further analysis
while maintaining high resolution to zoom in on fine signal details.
A dedicated, two-tier front-panel control provides intuitive control of both
zooming and panning. The inner control adjusts the zoom factor (or zoom
scale); turning it clockwise activates zoom and goes to progressively higher
zoom factors, while turning it counterclockwise results in lower zoom
factors and eventually turning zoom off. No longer do you need to navigate
through multiple menus to adjust your zoom view. The outer control pans
the zoom box across the waveform to quickly get to the portion of waveform
you are interested in. The outer control also utilizes force-feedback to
determine how fast to pan on the waveform. The farther you turn the outer
control, the faster the zoom box moves. Pan direction is changed by simply
turning the control the other way.
User marks
Press the Set Mark front-panel button to place one or more marks on the
waveform. Navigating between marks is as simple as pressing the
Previous (←) and Next (→) buttons on the front panel.
Search marks
The Search button allows you to automatically search through your long
acquisition looking for user-defined events. All occurrences of the event are
highlighted with search marks and are easily navigated to, using the front-
panel Previous (←) and Next (→) buttons. Search types include edge,
pulse width/glitch, timeout, runt, logic, setup and hold, rise/fall time, parallel
bus, and I2C, SPI, RS-232/422/485/UART, USB 2.0, CAN, CAN FD, LIN,
FlexRay, MIL-STD-1553, ARINC-429, and Audio packet content. A search
mark table provides a tabular view of the events found during the
automated search. Each event is shown with a time stamp, making timing
measurements between events easy.
Over 125 trigger combinations make capturing your event of interest easy.
®
Wave Inspector waveform navigation and automated
search
With long record lengths, a single acquisition can include thousands of
®
screens of waveform data. Wave Inspector , the industry’s best tool for
waveform navigation and automated search, enables you to find events of
interest in seconds.
Search step 1: You define what you would like to find.
Wave Inspector controls provide unprecedented efficiency in viewing, navigating, and
analyzing waveform data. Zip through your long record by turning the outer pan control
(1). Get details from the beginning to end in seconds. See something of interest and want
to see more details? Just turn the inner zoom control (2).
6 www.tek.com
Mixed Domain Oscilloscopes -- MDO3000 Series
Search step 2: Wave Inspector automatically searches through the record and marks
each event with a hollow white triangle. You can then use the Previous and Next buttons
to jump from one event to the next.
Automated measurement readouts provide repeatable, statistical views of waveform
characteristics.
Each measurement has help text and graphics associated with it that help explain how
the measurement is made.
Search step 3: The Search Mark table provides a tabular view of each of the events
found by the automated search. Each event is shown with a time stamp making timing
measurements between events easy.
Waveform histograms show visually how waveforms vary over time.
Horizontal waveform histograms are especially useful for gaining insight
into how much jitter is on a clock signal, and what the distribution of that
jitter is. Vertical histograms are especially useful for gaining insight into how
much noise is on a signal, and what the distribution of that noise is.
Waveform analysis
Verifying that your prototype’s performance matches simulations and meets
the project’s design goals requires analyzing its behavior. Tasks can range
from simple checks of rise times and pulse widths to sophisticated power
loss analysis and investigation of noise sources.
Measurements taken on a waveform histogram provide analytical
information about the distribution of a waveform histogram, providing
insight into just how broad a distribution is, the amount of standard
deviation, the mean value, etc.
The oscilloscope offers a comprehensive set of integrated analysis tools
including waveform- and screen-based cursors, automated measurements,
advanced waveform math including arbitrary equation editing, FFT
analysis, waveform histograms, and trend plots for visually determining how
a measurement is changing over time.
www.tek.com
7
Datasheet
Waveform histogram of a rising edge showing the distribution of edge position (jitter) over
time. Included are numeric measurements made on the waveform histogram data.
Viewing an NTSC full color bar signal image. Video picture mode contains automatic
contrast and brightness settings as well as manual controls.
Video design and development
Power analysis (optional)
Many video engineers have remained loyal to analog oscilloscopes,
believing the intensity gradations on an analog display are the only way to
see certain video waveform details. The fast waveform capture rate of the
MDO3000, coupled with its intensity-graded view of the signal, provides the
same information-rich display as an analog oscilloscope, but with much
more detail and all the benefits of digital scopes.
Ever increasing consumer demands for longer battery-life devices and for
green solutions that consume less power require power-supply designers to
characterize and minimize switching losses to improve efficiency. In
addition, the supply’s power levels, output purity, and harmonic feedback
into the power line must be characterized to comply with national and
regional power quality standards. Historically, making these and many
other power measurements on an oscilloscope has been a long, manual,
and tedious process. The MDO3000’s optional power analysis tools greatly
simplify these tasks, enabling quick, repeatable and accurate analysis of
power quality, switching loss, harmonics, safe operating area (SOA),
modulation, ripple, and slew rate (di/dt, dv/dt). Completely integrated into
the oscilloscope, the power analysis tools provide automated, repeatable
power measurements with a touch of a button. The optional power analysis
functionality is offered free for a 30-day trial period. This free trial period
starts automatically when the instrument is powered on for the first time.
Standard features such as IRE and mV graticules, holdoff by fields, video
polarity, HDTV and custom (nonstandard) video triggers, and an Autoset
smart enough to detect video signals, make these the easiest to use
oscilloscopes on the market for video applications. And with high
bandwidth, four analog inputs, and a built-in 75 Ω input termination (not
available on 1 GHz models), the oscilloscope provides ample performance
for analog and digital video use. There is even a video picture mode
enabling you to see the picture of the video signal you are viewing – for
NTSC and PAL signals.
Power Quality measurement table. Automated power measurements enable quick and
accurate analysis of common power parameters.
Viewing an NTSC video signal. Notice the intensity-graded view provided by the
MDO3000's ability to represent time, amplitude, and distribution over time.
8 www.tek.com
Mixed Domain Oscilloscopes -- MDO3000 Series
Limit/Mask testing (optional)
Fast and accurate spectral analysis
A common task during the development process is characterizing the
behavior of certain signals in a system. One method, called limit testing, is
to compare a tested signal to a known good or "golden" version of the
same signal with user-defined vertical and horizontal tolerances. Another
common method, called mask testing, is to compare a tested signal to a
mask, looking for where a signal under test violates the mask. The
MDO3000 Series offers both limit and mask testing capability useful for
long-term signal monitoring, characterizing signals during design, or testing
on a production line. Tailor a test to your specific requirements by defining
test duration in number of waveforms or time, a violation threshold that
must be met before considering a test a failure, counting hits along with
statistical information, and actions upon violations, test failure, and test
complete. Whether specifying a mask from a known good signal or from a
custom mask, conducting pass/fail tests in search of waveform anomalies
such as glitches has never been easier. The optional limit/mask test
functionality is offered free for a 30-day trial period. This free trial period
starts automatically when the instrument is powered on for the first time.
When using the spectrum analyzer input, the MDO3000 Series display
becomes a full-screen Frequency Domain view.
Key spectral parameters such as Center Frequency, Span, Reference
Level, and Resolution Bandwidth are all adjusted quickly and easily using
the dedicated front-panel menus and keypad.
MDO3000 frequency domain display.
Intelligent, efficient markers
In a traditional spectrum analyzer, it can be a very tedious task to turn on
and place enough markers to identify all your peaks of interest. The
MDO3000 Series makes this process far more efficient by automatically
placing markers on peaks that indicate both the frequency and the
amplitude of each peak. You can adjust the criteria that the oscilloscope
uses to automatically find the peaks.
The highest amplitude peak is referred to as the reference marker and is
shown in red. Marker readouts can be switched between Absolute and
Delta readouts. When Delta is selected, marker readouts show each peak's
delta frequency and delta amplitude from the reference marker.
Limit Test showing a mask created from a golden waveform and compared against a live
signal. Results showing statistical information about the test are displayed.
Two manual markers are also available for measuring non-peak portions of
the spectrum. When enabled, the reference marker is attached to one of
the manual markers, enabling delta measurements from anywhere in the
spectrum. In addition to frequency and amplitude, manual marker readouts
also include noise density and phase noise readouts depending on whether
Absolute or Delta readouts are selected. A "Reference Marker to Center"
function instantly moves the frequency indicated by the reference marker to
center frequency.
2 – Spectrum Analyzer
The MDO3000 is the first oscilloscope in its class to include an integrated
spectrum analyzer. Each oscilloscope includes a spectrum analyzer with a
frequency range of 9 kHz up to the analog bandwidth of the instrument. The
spectrum analyzer frequency range of each instrument can be upgraded
from 9 kHz to 3 GHz (option MDO3SA), enabling spectral analysis on most
consumer wireless standards.
www.tek.com
9
Datasheet
Ultra-wide capture bandwidth
Today's wireless communications vary significantly with time, using
sophisticated digital modulation schemes and, often, transmission
techniques that involve bursting the output. These modulation schemes can
have very wide bandwidth as well. Traditional swept or stepped spectrum
analyzers are ill equipped to view these types of signals as they are only
able to look at a small portion of the spectrum at any one time.
The amount of spectrum acquired in one acquisition is called the capture
bandwidth. Traditional spectrum analyzers sweep or step the capture
bandwidth through the desired span to build the requested image. As a
result, while the spectrum analyzer is acquiring one portion of the spectrum,
the event you care about may be happening in another portion of the
spectrum. Most spectrum analyzers on the market today have 10 MHz
capture bandwidths, sometimes with expensive options to extend that to
20, 40, or even 160 MHz in some cases.
Automated peak markers identify critical information at a glance. As shown here, the five
highest amplitude peaks that meet the threshold and excursion criteria are automatically
marked along with the peak's frequency and amplitude.
In order to address the bandwidth requirements of modern RF, the
MDO3000 Series provides up to 3 GHz of capture bandwidth. The
spectrum is generated from a single acquisition, thus guaranteeing you'll
see the events you're looking for in the frequency domain.
Spectrogram
The MDO3000 Series includes a spectrogram display which is ideal for
monitoring slowly changing RF phenomena. The x-axis represents
frequency, just like a typical spectrum display. However, the y-axis
represents time, and color is used to indicate amplitude.
Spectrogram slices are generated by taking each spectrum and "flipping it
up on its edge" so that it's one pixel row tall, and then assigning colors to
each pixel based on the amplitude at that frequency. Cold colors (blue,
green) are low amplitude and hotter colors (yellow, red) are higher
amplitude. Each new acquisition adds another slice at the bottom of the
spectrogram and the history moves up one row. When acquisitions are
stopped, you can scroll back through the spectrogram to look at any
individual spectrum slice.
Spectral display of a bursted communication both into a device through Zigbee at
900 MHz and out of the device through Bluetooth at 2.4 GHz, captured with a single
acquisition.
Spectrum traces
The MDO3000 Series spectrum analyzer offers four different traces or
views including Normal, Average, Max Hold, and Min Hold.
Spectrogram display illustrates slowly moving RF phenomena. As shown here, a signal
that has multiple peaks is being monitored. As the peaks change in both frequency and
amplitude over time, the changes are easily seen in the Spectrogram display.
10 www.tek.com
Mixed Domain Oscilloscopes -- MDO3000 Series
Normal, Average, Max Hold, and Min Hold spectrum traces
RF measurements
The optional TPA-N-VPI adapter enables any active, 50 Ω TekVPI probe to be
connected to the RF input.
The MDO3000 Series includes three automated RF measurements -
Channel Power, Adjacent Channel Power Ratio, and Occupied Bandwidth.
When one of these RF measurements is activated, the oscilloscope
automatically turns on the Average spectrum trace and sets the detection
method to Average for optimal measurement results.
3 – Arbitrary Function Generator (optional)
The MDO3000 contains an optional integrated arbitrary function generator
(option MDO3AFG), perfect for simulating sensor signals within a design or
adding noise to signals to perform margin testing.
The integrated function generator provides output of predefined waveforms
up to 50 MHz for sine, square, pulse, ramp/triangle, DC, noise, sin(x)/x
(Sinc), Gaussian, Lorentz, exponential rise/fall, Haversine and cardiac.
Automated Channel Power measurement
RF probing
Signal input methods on spectrum analyzers are typically limited to cabled
connections or antennas. But with the optional TPA-N-VPI adapter, any
active, 50 Ω TekVPI probe can be used with the spectrum analyzer on the
MDO3000 Series. This enables additional flexibility when hunting for noise
sources and enables easier spectral analysis by using true signal browsing
on a spectrum analyzer input.
Waveform type selection in the integrated AFG.
In addition, an optional preamplifier accessory assists in the investigation of
lower-amplitude signals. The TPA-N-PRE preamplifier provides 10 dB
nominal gain across the 9 kHz – 3 GHz frequency range.
www.tek.com 11
Datasheet
Color-coded digital waveform display
The arbitrary waveform generator provides 128 k points of record for
storing waveforms from the analog input, a saved internal file location, a
USB mass storage device, or from an external PC. Once a waveform is in
the edit memory of the arbitrary waveform generator, it can be modified via
an on-screen editor and then replicated out of the generator. The
MDO3000 is compatible with Tektronix’ ArbExpress PC-based waveform
creation and editing software, making creation of complex waveforms fast
and easy. Transfer waveform files to your MDO3000 edit memory via USB
or LAN or using a USB mass storage device to be output from the AFG in
the oscilloscope.
Color-coded digital traces display ones in green and zeros in blue. This
coloring is also used in the digital channel monitor. The monitor shows if
signals are high, low, or are transitioning so you can see channel activity at
a glance without having to clutter your display with unneeded digital
waveforms.
The multiple transition detection hardware shows you a white edge on the
display when the system detects multiple transitions. White edges indicate
that more information is available by zooming in or acquiring at faster
sampling rates. In most cases zooming in will reveal the pulse that was not
viewable with the previous settings. If the white edge is still present after
zooming in as far as possible, this indicates that increasing the sample rate
on the next acquisition will reveal higher frequency information than the
previous settings could acquire.
You can group digital waveforms and enter waveform labels by using a
USB keyboard. By simply placing digital waveforms next to each other, they
form a group.
Arbitrary waveform editor showing the point-by-point editor.
4 – Logic Analyzer (optional)
The logic analyzer (option MDO3MSO) provides 16 digital channels which
are tightly integrated into the oscilloscope's user interface. This simplifies
operation and makes it possible to solve mixed-signal issues easily.
With color-coded digital waveform display, groups are created by simply placing digital
channels together on the screen, allowing digital channels to be moved as a group.
Once a group is formed, you can position all the channels contained in that
group collectively. This greatly reduces the normal setup time associated
with positioning channels individually
The MDO3000 with MDO3MSO option provides 16 integrated digital channels enabling
you to view and analyze time-correlated analog and digital signals.
12 www.tek.com
Mixed Domain Oscilloscopes -- MDO3000 Series
™
MagniVu high-speed acquisition
5 – Serial Protocol Triggering and Analysis
(optional)
The main digital acquisition mode on the MDO3000 Series will capture up
to 10 M at 500 MS/s (2 ns resolution). In addition to the main record, the
MDO3000 provides an ultra high-resolution record called MagniVu which
acquires 10,000 points at up to 8.25 GS/s (121.2 ps resolution). Both main
and MagniVu waveforms are acquired on every trigger and can be switched
between in the display at any time, running or stopped. MagniVu provides
significantly finer timing resolution than comparable oscilloscopes on the
market, instilling confidence when making critical timing measurements on
digital waveforms.
On a serial bus, a single signal often includes address, control, data, and
clock information. This can make isolating events of interest difficult.
Automatic trigger, decode, and search on bus events and conditions gives
you a robust set of tools for debugging serial buses. The optional serial
protocol triggering and analysis functionality is offered free for a 30-day trial
period. This free trial period starts automatically when the instrument is
powered on for the first time.
Triggering on a specific address and data packet going across an I2C bus. The yellow
waveform is clock and the blue waveform is the data. A bus waveform provides decoded
packet content including Start, Address, Read/Write, Data, and Stop.
The MagniVu high-resolution record provides 121.2 ps timing resolution, enabling you to
take critical timing measurements on your digital waveforms.
P6316 MSO probe
Serial triggering
This unique probe design offers two eight-channel pods, simplifying the
process of connecting to the device-under-test. When connecting to square
pins, the P6316 can connect directly to 8×2 square pin headers spaced on
tenth-inch centers. When more attachment flexibility is required, you can
use the included flying lead sets and grabbers to clip onto surface mount
devices or test points. The P6316 offers outstanding electrical
characteristics applying only 8 pF of capacitive loading with 101 kΩ input
impedance.
Trigger on packet content such as start of packet, specific addresses,
specific data content, unique identifiers, etc. on popular serial interfaces
such as I2C, SPI, RS-232/422/485/UART, USB2.0, CAN, CAN FD, LIN,
FlexRay, MIL-STD-1553, ARINC-429, and I2S/LJ/RJ/TDM.
Bus display
Provides a higher-level, combined view of the individual signals (clock,
data, chip enable, etc.) that make up your bus, making it easy to identify
where packets begin and end and identifying sub-packet components such
as address, data, identifier, CRC, etc.
Bus decoding
Tired of having to visually inspect the waveform to count clocks, determine
if each bit is a 1 or a 0, combine bits into bytes, and determine the hex
value? Let the oscilloscope do it for you! Once you’ve set up a bus, the
MDO3000 Series will decode each packet on the bus, and display the value
in hex, binary, decimal (USB, CAN, CAN FD, LIN, FlexRay, MIL-STD-1553,
and ARINC-429 only), signed decimal (I2S/LJ/RJ/TDM only), or ASCII
(USB, MIL-STD-1553 and RS-232/422/485/UART only) in the bus
waveform.
The P6316 MSO probe offers two eight-channel pods to simplify connecting to your
device.
www.tek.com 13
Datasheet
Search (serial triggering)
Serial bus technologies supported by the MDO3000
Serial triggering is very useful for isolating the event of interest, but once
you’ve captured it and need to analyze the surrounding data, what do you
do? In the past, users had to manually scroll through the waveform
counting and converting bits and looking for what caused the event. You
can have the oscilloscope automatically search through the acquired data
for user-defined criteria including serial packet content. Each occurrence is
highlighted by a search mark. Rapid navigation between marks is as simple
as pressing the Previous (←) and Next (→) buttons on the front panel.
Technology
Trigger, Decode, Order product
Search
Embedded
I2C
Yes
MDO3EMBD
MDO3EMBD
MDO3COMP
SPI
Yes
Computer
USB
RS232/422/485,
UART
Yes
USB LS, FS, HS
Yes (trigger on LS MDO3USB
and FS only; HS
decode only on
1 GHz models)
6 – Digital Voltmeter (DVM) and Frequency
Counter
Automotive
CAN, CAN FD
LIN
Yes
Yes
Yes
Yes
MDO3AUTO
MDO3AUTO
MDO3FLEX
MDO3AERO
The MDO3000 contains an integrated 4-digit digital voltmeter (DVM) and 5-
digit frequency counter. Any of the analog inputs can be a source for the
voltmeter, using the same probes that are already attached for general
oscilloscope usage. The easy-to-read display offers you both numeric and
graphical representations of the changing measurement values. The
display also shows minimum, maximum, and average values of the
measurement as well as the range of values measured over the previous
five second interval. The DVM and frequency counter is available on any
MDO3000 and is activated when you register your product.
FlexRay
Military and
Aerospace
MIL-STD-1553,
ARINC-429
Audio
I2S
Yes
Yes
Yes
MDO3AUDIO
MDO3AUDIO
MDO3AUDIO
LJ, RJ
TDM
Event table
In addition to seeing decoded packet data on the bus waveform itself, you
can view all captured packets in a tabular view much like you would see in
a software listing. Packets are time stamped and listed consecutively with
columns for each component (Address, Data, etc.). You can save the event
table data in .CSV format.
A DC measurement value is shown with a five second variation along with minimum,
maximum, and average voltage values. The frequency of the waveform is also shown.
Event table showing decoded identifier, DLC, DATA, and CRC for every CAN packet in a
long acquisition.
14 www.tek.com
Mixed Domain Oscilloscopes -- MDO3000 Series
The MDO3000 Series Platform
Large high-resolution display
The MDO3000 Series features a 9 inch (229 mm) wide-screen, high-
resolution (800 × 480 WVGA) display for seeing intricate signal details.
Connectivity
The MDO3000 contains a number of ports which can be used to connect
the instrument to a network, directly to a PC, or other test equipment.
Front and rear USB host ports enable easy transfer of screen shots,
instrument settings, and waveform data to a USB mass storage device.
A USB keyboard can also be attached to a USB host port for data
entry.
Rear USB device port is useful for controlling the oscilloscope remotely
from a PC or for printing directly to a PictBridge -compatible printer.
®
e*Scope in a web browser showing the display of an MDO3000. Use e*Scope to quickly
document your work by saving screen images, waveforms, or setups for later use.
The standard 10/100 Ethernet port on the rear of the instrument
enables easy connection to networks, provides network and e-mail
printing, and provides LXI Core 2011 compatibility.
Compact form factor
With the compact, portable form factor, you can easily move the
oscilloscope between labs. And with a depth of just 5.8 inches (147 mm), it
saves you valuable space on your test bench. The MDO3000 has all the
tools you'll need for everyday debug tasks, all in a single instrument.
A video out port on the rear of the instrument allows the display to be
exported to an external monitor or projector.
Remote connectivity and instrument control
Exporting data and measurements is as simple as connecting a USB cable
from the oscilloscope to your PC. Key software applications –
®
OpenChoice Desktop, and Microsoft Excel and Word toolbars – are
included standard with each oscilloscope to enable fast and easy direct
communication with your Windows PC.
The included OpenChoice Desktop enables fast and easy communication
between the oscilloscope and your PC through USB or LAN for transferring
settings, waveforms, and screen images.
®
The embedded e*Scope capability enables fast control of the oscilloscope
over a network connection through a standard web browser. Simply enter
the IP address or network name of the oscilloscope and a web page will be
served to the browser. Transfer and save settings, waveforms,
measurements, and screen images or make live control changes to settings
on the oscilloscope directly from the web browser.
The MDO3000 Series compact form factor frees up valuable space on your bench or
desktop while making sure you will always have the debug tools you need.
Accurate high-speed probing
The MDO3000 Series scope ships standard with passive voltage probes
and uses the TekVPI probe interface.
Standard passive voltage probes – The MDO3000 Series include
passive voltage probes with industry best capacitive loading of only 3.9 pF.
The included TPP probes minimize the impact on devices under test and
accurately deliver signals to the oscilloscope for acquisition and analysis.
The following table shows which TPP probes come standard with each
MDO3000 model.
www.tek.com 15
Datasheet
MDO3000 model
Included probe
MDO3012, MDO3014,
MDO3022, MDO3024
TPP0250: 250 MHz, 10x passive voltage
probe. One per analog channel
MDO3032, MDO3034,
MDO3052, MDO3054
TPP0500B: 500 MHz, 10x passive
voltage probe. One per analog channel
MDO3102, MDO3104
TPP1000: 1 GHz, 10x passive voltage
probe. One per analog channel
®
TekVPI probe interface – The TekVPI probe interface sets the standard
for ease of use in probing. In addition to the secure, reliable connection that
the interface provides, TekVPI probes feature status indicators and
controls, as well as a probe menu button right on the comp box itself. This
button brings up a probe menu on the oscilloscope display with all relevant
settings and controls for the probe. The TekVPI interface enables direct
attachment of current probes without requiring a separate power supply.
TekVPI probes can be controlled remotely through USB, GPIB, or LAN,
enabling more versatile solutions in ATE environments. The instrument
provides up to 25 W of power to the front panel connectors from the internal
power supply.
TekVPI probe interface simplifies connecting your probes to the oscilloscope.
16 www.tek.com
Mixed Domain Oscilloscopes -- MDO3000 Series
Specifications
All specifications are guaranteed unless noted otherwise. All specifications apply to all models unless noted otherwise.
1 – Oscilloscope
MDO3012 MDO3014 MDO3022 MDO3024 MDO3032 MDO3034 MDO3052 MDO3054 MDO3102 MDO3104
Analog channels
2
4
2
4
2
4
2
4
2
4
Analog channel bandwidth 100 MHz
100 MHz
4 ns
200 MHz
2 ns
200 MHz
2 ns
350 MHz
1.14 ns
350 MHz
1.14 ns
500 MHz
800 ps
500 MHz
800 ps
1 GHz
400 ps
1 GHz
400 ps
Rise time (typical,
calculated)
4 ns
(10 mV/div setting with
50 Ω input termination)
Sample rate (1 ch)
Sample rate (2 ch)
Sample rate (4 ch)
Record length (1 ch)
Record length (2 ch)
Record length (4 ch)
2.5 GS/s
2.5 GS/s
2.5 GS/s
2.5 GS/s
10 M
2.5 GS/s
2.5 GS/s
2.5 GS/s
2.5 GS/s
10 M
2.5 GS/s
2.5 GS/s
2.5 GS/s
2.5 GS/s
10 M
2.5 GS/s
2.5 GS/s
2.5 GS/s
2.5 GS/s
10 M
5 GS/s
5 GS/s
-
5 GS/s
5 GS/s
2.5 GS/s
10 M
2.5 GS/s
2.5 GS/s
2.5 GS/s
2.5 GS/s
-
-
-
-
10 M
10 M
-
10 M
10 M
-
10 M
10 M
-
10 M
10 M
-
10 M
10 M
-
10 M
10 M
10 M
10 M
10 M
10 M
10 M
10 M
10 M
10 M
Digital channels with
MDO3MSO option
16
16
16
16
16
16
16
16
16
16
Arbitrary Function
Generator outputs with
MDO3AFG option
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Spectrum analyzer
channels
1
Standard spectrum
analyzer frequency range 100 MHz
9 kHz -
9 kHz -
100 MHz
9 kHz -
200 MHz
9 kHz -
200 MHz
9 kHz -
350 MHz
9 kHz -
350 MHz
9 kHz -
500 MHz
9 kHz -
500 MHz
9 kHz -
1 GHz
9 kHz -
1 GHz
Optional spectrum 9 kHz -
analyzer frequency range 3 GHz
with MDO3SA option
9 kHz -
3 GHz
9 kHz -
3 GHz
9 kHz -
3 GHz
9 kHz -
3 GHz
9 kHz -
3 GHz
9 kHz -
3 GHz
9 kHz -
3 GHz
9 kHz -
3 GHz
9 kHz -
3 GHz
Vertical system analog channels
Hardware bandwidth limits
≥350 MHz models
20 MHz or 250 MHz
100 MHz and 200 MHz models 20 MHz
Input coupling
AC, DC
Input impedance
1 MΩ ±1%, 50 Ω ±1%, 75 Ω ±1%; 75 Ω not available on 1 GHz models
Input sensitivity range
1 MΩ
1 mV/div to 10 V/div
1 mV/div to 1 V/div
50 Ω, 75 Ω
Vertical resolution
8 bits (11 bits with Hi Res)
www.tek.com 17
Datasheet
Vertical system analog channels
Maximum input voltage
1 MΩ
300 VRMS CAT II with peaks ≤ ±425 V
50 Ω, 75 Ω
5 VRMS with peaks ≤ ±20 V
DC gain accuracy
±1.5% for 5 mV/div and above, derated at 0.10%/°C above 30 °C
±2.0% for 2 mV/div, derated at 0.10%/°C above 30 °C
±2.5% for 1 mV/div, derated at 0.10%/°C above 30 °C
±3.0% for variable gain, derated 0.10%/°C above 30 °C
Channel-to-channel isolation
(typical)
Any two channels at equal vertical scale ≥100:1 at ≤100 MHz and ≥30:1 at >100 MHz up to the rated bandwidth
Random noise (typical)
Vertical scale
setting
50 Ω, RMS
MDO310x
0.179 mV
2.4 mV
MDO305x
0.178 mV
2.05 mV
MDO303x
0.169 mV
1.97 mV
MDO302x
0.178 mV
1.93 mV
MDO301x
0.161 mV
1.87 mV
1 mV/div
100 mV/div
1 V/div
24.67 mV
20.96 mV
20.01 mV
19.39 mV
18.55 mV
Offset range
Volts/div setting
Offset range
1 M Ω input
±1 V
50 Ω, 75 Ω input
±1 V
1 mV/div to 50 mV/div
50.5 mV/div to 99.5 mV/div
100 mV/div to 500 mV/div
505 mV/div to 995 mV/div
1 V/div to 10 V/div
±0.5 V
±0.5 V
±10 V
±10 V
±5 V
±5 V
±100 V
±5 V
Horizontal system analog channels
Time base range
1 GHz models
400 ps/div to 1000 s/div
≤ 500 MHz models
1 ns/div to 1000 s/div
Maximum duration at highest
sample rate (all/half channels)
1 GHz models
4/2 ms
4/4 ms
≤ 500 MHz models
Time-base delay time range
-10 divisions to 5000 s
Channel-to-channel deskew range ±125 ns
Time base accuracy
±10 ppm over any ≥1 ms interval
18 www.tek.com
Mixed Domain Oscilloscopes -- MDO3000 Series
Trigger system
Trigger modes
Auto, Normal, and Single
Trigger coupling
DC, AC, HF reject (attenuates >50 kHz), LF reject (attenuates <50 kHz), noise reject (reduces sensitivity)
Trigger holdoff range
Trigger sensitivity (typical)
20 ns to 8 s
Edge type, DC coupled
Trigger source
Sensitivity
Any analog channel input
For 1 mV/div to 4.98 mV/div; 0.75 div from DC to 50 MHz,
increasing to 1.3 div at instrument bandwidth
≥ 5 mV/div: 0.40 div from DC to 50 MHz, increasing to 1 div at
instrument bandwidth
Aux In (External); available on two-channel instruments only
Line
200 mV from DC to 50 MHz, increasing to 500 mV at 200 MHz
Fixed
Trigger level ranges
Any input channel
Aux In (External)
Line
±8 divisions from center of screen, ±8 divisions from 0 V when vertical LF reject trigger coupling is selected
±8 V
The line trigger level is fixed at about 50% of the line voltage.
Trigger frequency readout
Provides 6-digit frequency readout of triggerable events.
Trigger types
Edge
Positive, negative, or either slope on any channel. Coupling includes DC, AC, HF reject, LF reject, and noise reject.
Sequence (B-trigger)
Trigger Delay by Time: 8 ns to 8 s. Or Trigger Delay by Events: 1 to 4,000,000 events. Not available when “Either” edge is
selected.
Pulse Width
Timeout
Runt
Trigger on width of positive or negative pulses that are >, <, =, ≠, or inside/outside a specified period of time.
Trigger on an event which remains high, low, or either, for a specified time period (4 ns to 8 s).
Trigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again.
Logic
Trigger when any logical pattern of channels goes false or stays true for specified period of time. Any input can be used as a clock
to look for the pattern on a clock edge. Pattern (AND, OR, NAND, NOR) specified for all input channels defined as High, Low, or
Don’t Care.
Setup and Hold
Trigger on violations of both setup time and hold time between clock and data present on any of the analog and digital input
channels.
Setup and hold trigger type
Setup Time Range
Description
-0.5 ns to 1.024 ms
1.0 ns to 1.024 ms
0.5 ns to 2.048 ms
Hold Time Range
Setup + Hold Time Range
Rise/Fall Time
Video
Trigger on pulse edge rates that are faster or slower than specified. Slope may be positive, negative, or either and time range is
4.0 ns to 8 s.
Trigger on all lines, odd, even, or all fields on NTSC, PAL, and SECAM video signals.
480p/60, 576p/50, 720p/30, 720p/50, 720p/60, 875i/60, 1080i/50, 1080i/60, 1080p/24, 1080p/24sF, 1080p/25, 1080p/30,
1080p/50, 1080p/60
Custom bi-level and tri-level sync video standards.
Parallel (available when option Trigger on a parallel bus data value. Parallel bus can be from 1 to 20 bits (from the digital and analog channels) in size. Binary and
MDO3MSO is installed) Hex radices are supported.
www.tek.com 19
Datasheet
Acquisition system
Acquisition modes
Sample
Acquire sampled values.
Peak Detect
Captures glitches as narrow as 1.5 ns (1 GHz models), 2.0 ns (500 MHz models), 3.0 ns (350 MHz models), 5.0 ns (200 MHz
models), 7.0 ns (100 MHz models) at all sweep speeds
Averaging
Envelope
From 2 to 512 waveforms included in average.
Min-max envelope reflecting Peak Detect data over multiple acquisitions. Number of waveforms in the envelope selectable
between 1 and 2000 and infinity
Hi Res
Roll
Real-time boxcar averaging reduces random noise and increases vertical resolution.
Scrolls waveforms right to left across the screen at sweep speeds slower than or equal to 40 ms/div.
®
FastAcq
FastAcq optimizes the instrument for analysis of dynamic signals and capture of infrequent events, capturing >280,000 wfms/s on
1 GHz models and >235,000 wfms/s on 100 MHz – 500 MHz models.
Waveform measurements
Cursors
Waveform and Screen
Automatic measurements
(time domain)
30, of which up to four can be displayed on-screen at any one time. Measurements include: Period, Frequency, Delay, Rise Time,
Fall Time, Positive Duty Cycle, Negative Duty Cycle, Positive Pulse Width, Negative Pulse Width, Burst Width, Phase, Positive
Overshoot, Negative Overshoot, Total Overshoot, Peak to Peak, Amplitude, High, Low, Max, Min, Mean, Cycle Mean, RMS, Cycle
RMS, Positive Pulse Count, Negative Pulse Count, Rising Edge Count, Falling Edge Count, Area and Cycle Area.
Automatic measurements
(frequency domain)
3, of which one can be displayed on-screen at any one time. Measurements include Channel Power, Adjacent Channel Power
Ratio (ACPR), and Occupied Bandwidth (OBW)
Measurement statistics
Reference levels
Gating
Mean, Min, Max, Standard Deviation.
User-definable reference levels for automatic measurements can be specified in either percent or units.
Isolate the specific occurrence within an acquisition to take measurements on, using either the screen or waveform cursors.
Waveform histogram
A waveform histogram provides an array of data values representing the total number of hits inside of a user-defined region of the
display. A waveform histogram is both a visual graph of the hit distribution as well as a numeric array of values that can be
measured.
Sources
Types
Channel 1, Channel 2, Channel 3, Channel 4, Ref 1, Ref 2, Ref 3, Ref 4, Math
Vertical, Horizontal
Waveform histogram
measurements
12, of which up to four can be displayed on-screen at any one time. Waveform Count, Hits in Box, Peak Hits, Median, Max, Min,
Peak-to-Peak, Mean, Standard Deviation, Sigma 1, Sigma 2, Sigma 3
20 www.tek.com
Mixed Domain Oscilloscopes -- MDO3000 Series
Waveform math
Arithmetic
Add, subtract, multiply, and divide waveforms.
Integrate, differentiate, FFT
Math functions
FFT
Spectral magnitude. Set FFT Vertical Scale to Linear RMS or dBV RMS, and FFT Window to Rectangular, Hamming, Hanning, or
Blackman-Harris.
Spectrum math
Advanced math
Add or subtract frequency-domain traces.
Define extensive algebraic expressions including waveforms, reference waveforms, math functions (FFT, Intg, Diff, Log, Exp, Sqrt,
Abs, Sine, Cosine, Tangent, Rad, Deg), scalars, up to two user-adjustable variables and results of parametric measurements
(Period, Freq, Delay, Rise, Fall, PosWidth, NegWidth, BurstWidth, Phase, PosDutyCycle, NegDutyCycle, PosOverShoot,
NegOverShoot, TotalOverShoot, PeakPeak, Amplitude, RMS, CycleRMS, High, Low, Max, Min, Mean, CycleMean, Area,
CycleArea, and trend plots). For example, (Intg(Ch1 - Mean(Ch1)) × 1.414 × VAR1)
Act on Event
Events
None, when a trigger occurs, or when a defined number of acquisitions complete (1 to 1,000,000)
Actions
Repeat
Stop acquisition, save waveform to file, save screen image, print, AUX OUT pulse, remote interface SRQ, e-mail notification, and
visual notification
Repeat the act on event process (1 to 1,000,000 and infinity)
Video Picture mode
Sources
Channel 1, Channel 2, Channel 3, Channel 4
Video standards
NTSC, PAL
Contrast and brightness
Field selection
Manual and automatic
Odd, Even, Interlaced
Picture location on screen
Selectable X and Y location, width and height adjustment, start line and pixel and line-to-line offset control.
www.tek.com 21
Datasheet
Power measurements (optional)
Power quality measurements
VRMS, VCrest Factor, Frequency, IRMS, ICrest Factor, True Power, Apparent Power, Reactive Power, Power Factor, Phase Angle.
Switching loss measurements
Power loss
Ton, Toff, Conduction, Total.
Ton, Toff, Conduction, Total.
Energy loss
Harmonics
THD-F, THD-R, RMS measurements. Graphical and table displays of harmonics. Test to IEC61000-3-2 Class A and MIL-
STD-1399, Section 300A.
Ripple measurements
Modulation analysis
VRipple and IRipple.
Graphical display of +Pulse Width, -Pulse Width, Period, Frequency, +Duty Cycle, and -Duty Cycle modulation types.
Graphical display and mask testing of switching device safe operating area measurements.
Cursor measurements of slew rate
Safe operating area
dV/dt and dI/dt measurements
Limit/Mask testing (optional)
Test source
Limit test: Any Ch1 - Ch4 or any R1 - R4
Mask test: Any Ch1 - Ch4
Mask creation
Limit test vertical tolerance from 0 to 1 division in 1 m division increments; Limit test horizontal tolerance from 0 to 500 m division in
1 m division increments.
Load custom mask from text file with up to 8 segments.
Mask scaling
Lock to Source ON (mask automatically re-scales with source-channel settings changes)
Lock to Source OFF (mask does not re-scale with source-channel settings changes)
Test criteria run until
Minimum number of waveforms (from 1 to 1,000,000 and Infinity)
Minimum elapsed time (from 1 second to 48 hours and Infinity)
Violation threshold
Actions on test failure
Actions on test complete
Results display
From 1 to 1,000,000 and Infinity
Stop acquisition, save screen image to file, save waveform to file, print screen image, AUX OUT pulse, set remote interface SRQ
AUX OUT pulse, set remote interface SRQ
Test status, total waveforms, number of violations, total tests, failed tests, elapsed time, total hits for each mask segment
22 www.tek.com
Mixed Domain Oscilloscopes -- MDO3000 Series
2 – Spectrum Analyzer
Capture bandwidth
MDO3012, MDO3014 models: 100 MHz
MDO3022, MDO3024 models: 200 MHz
MDO3032, MDO3034 models: 350 MHz
MDO3052, MDO3054 models: 500 MHz
MDO3102, MDO3104 models: 1 GHz
All models: 3 GHz with option MDO3SA
Span
MDO3012, MDO3014 models: 9 kHz – 100 MHz
MDO3022, MDO3024 models: 9 kHz – 200 MHz
MDO3032, MDO3034 models: 9 kHz – 350 MHz
MDO3052, MDO3054 models: 9 kHz – 500 MHz
MDO3102, MDO3104 models: 9 kHz – 1 GHz
All models: 9 kHz – 3 GHz with option MDO3SA, in a 1-2-5 sequence
Resolution bandwidth
Reference level
Vertical scale
20 Hz - 150 MHz in a 1-2-3-5 sequence
-130 dBm to +20 dBm in steps of 5 dBm
1 dB/div to 20 dB/div in a 1-2-5 sequence
-100 divs to +100 divs (displayed in dB)
Vertical position
Vertical units
dBm, dBmV, dBµV, dBµW, dBmA, dBµA
Displayed average noise level
(DANL)
9 kHz - 50 kHz
50 kHz – 5 MHz
5 MHz - 2 GHz
2 GHz – 3 GHz
< -109 dBm/Hz (< -113 dBm/Hz typical)
< -126 dBm/Hz (< -130 dBm/Hz typical)
< -136 dBm/Hz (< -140 dBm/Hz typical)
< -126 dBm/Hz (< -130 dBm/Hz typical)
DANL with TPA-N-PRE preamp
attached
Preamp set to "Auto", and Reference Level set to -40 dB
9 kHz - 50 kHz
50 kHz – 5 MHz
5 MHz - 2 GHz
2 GHz – 3 GHz
< -117 dBm/Hz (< -121 dBm/Hz typical)
< -136 dBm/Hz (< -140 dBm/Hz typical)
< -146 dBm/Hz (< -150 dBm/Hz typical)
< -136 dBm/Hz (< -140 dBm/Hz typical)
Spurious response
2nd harmonic distortion
(>100 MHz)
3rd harmonic distortion
(>100 MHz)
2nd order intermodulation
distortion (>15 MHz)
3rd order intermodulation
distortion (>15 MHz)
< -55 dBc (< -60 dBc typical)
< -53 dBc (< -58 dBc typical)
< -55 dBc (< -60 dBc typical)
< -55 dBc (< -60 dBc typical)
www.tek.com 23
Datasheet
2 – Spectrum Analyzer
Residual response
At 2.5 GHz
< -78 dBm (≤ -15 dBm reference level and RF input terminated with 50 Ω)
<-67 dBm
<-76 dBm
At 1.25 GHz
Crosstalk to spectrum analyzer
from oscilloscope channels
≤800 MHz input frequencies
< -60 dB from ref level (typical)
< -40 dB from ref level (typical)
>800 MHz - 2 GHz input
frequencies
Phase noise at 1 GHz CW
10 kHz
100 kHz
1 MHz
< -81 dBc/Hz, < -85 dBc/Hz (typical)
< -97 dBc/Hz, < -101 dBc/Hz (typical)
< -118 dBc/Hz, < -122 dBc/Hz (typical)
Level measurement uncertainty
Reference level 10 dBm to -15 dBm. Input level ranging from reference level to 40 dB below reference level. Specifications
exclude mismatch error.
18 °C - 28 °C
< ±1.2 dBm (< ±0.6 dBm typical)
< ±2.0 dBm
Over operating range
Level measurement uncertainty
Preamp mode set to “Auto”. Reference level 10 dBm set to -40dBm. Input level ranging from reference level to 30 dB below
with TPA-N-PRE preamp attached reference level. Specifications exclude mismatch error.
18 °C - 28 °C
< ±1.5 dBm (typical) either preamp state
< ±2.3 dBm either preamp state
Over operating range
Frequency measurement accuracy ±(([Reference Frequency Error] x [Marker Frequency]) + (span/750 + 2)) Hz; Reference Frequency Error = 10ppm (10 Hz / MHz)
Maximum operating input level
Average continuous power
+20 dBm (0.1 W)
DC maximum before damage ±40 V DC
Maximum power before
damage (CW)
+33 dBm (2 W)
+45 dBm (32 W) (<10 µs pulse width, <1% duty cycle, and reference level of ≥ +10 dBm)
Maximum power before
damage (pulse)
Maximum operating input level
with TPA-N-PRE preamp attached
Average continuous power
+20 dBm (0.1 W)
DC maximum before damage ±20 V DC
Maximum power before
damage (CW)
+30 dBm (1 W)
Maximum power before
damage (pulse)
+45 dBm (32 W) (<10 μs pulse width, <1% duty cycle, and reference level of ≥ +10 dBm)
Frequency domain trace types
Detection methods
Normal, Average, Max Hold, Min Hold
+Peak, -Peak, Average, Sample
Automatic markers
One to eleven peaks identified based on user-adjustable threshold and excursion values
Two manual markers indicating frequency, amplitude, noise density, and phase noise
Manual markers
24 www.tek.com
Mixed Domain Oscilloscopes -- MDO3000 Series
2 – Spectrum Analyzer
Marker readouts
Absolute or Delta
FFT windows
FFT window
Kaiser
Factor
2.23
0.89
1.30
1.44
1.90
3.77
Rectangular
Hamming
Hanning
Blackman-Harris
Flat-Top
3 – Arbitrary Function Generator
(Requires MDO3AFG option)
Waveforms
Sine, Square, Pulse, Ramp/Triangle, DC, Noise, Sin(x)/x (Sinc), Gaussian, Lorentz, Exponential Rise, Exponential Decay,
Haversine, Cardiac, and Arbitrary.
Sine
Frequency range
0.1 Hz to 50 MHz
Amplitude range
20 mVp-p to 5 Vp-p into Hi-Z; 10 mVp-p to 2.5 Vp-p into 50 Ω
±0.5 dB at 1 kHz (±1.5 dB for <20 mVp-p amplitudes)
1% into 50 Ω
Amplitude flatness (typical)
Total harmonic distortion
(typical)
2% for amplitude < 50 mV and frequencies > 10 MHz
3% for amplitude < 20 mV and frequencies > 10 MHz
Spurious free dynamic range -40 dBc (Vp-p ≥ 0.1 V); -30dBc (Vp-p ≤ 0.1 V), 50 Ω load
(SFDR) (typical)
Square / Pulse
Frequency range
0.1 Hz to 25 MHz
Amplitude range
Duty cycle
20 mVp-p to 5 Vp-p into Hi-Z; 10 mVp-p to 2.5 Vp-p into 50 Ω
10% to 90% or 10 ns minimum pulse, whichever is larger cycle
0.1%
Duty cycle resolution
Pulse width minimum (typical) 10 ns
Rise/fall time (typical)
Pulse width resolution
Overshoot (typical)
Asymmetry
5 ns (10% - 90%)
100 ps
< 2% for signal steps greater than 100 mV
±1% ±5 ns, at 50% duty cycle
< 500 ps
Jitter (TIE RMS) (typical)
Ramp / Triangle
Frequency range
Amplitude range
0.1 Hz to 500 kHz
20 mVp-p to 5 Vp-p into Hi-Z; 10 mVp-p to 2.5 Vp-p into 50 Ω
Variable symmetry
Symmetry resolution
0% to 100%
0.1%
DC
Level range (typical)
±2.5 V into Hi-Z; ±1.25 V into 50 Ω
www.tek.com 25
Datasheet
3 – Arbitrary Function Generator
Noise
Amplitude range
20 mVp-p to 5 Vp-p in to Hi-Z; 10 mVp-p to 2.5 Vp-p into 50 Ω
Amplitude resolution
0% to 100% in 1% increments
Sin(x)/x (Sinc)
Frequency range (typical)
Amplitude range
0.1 Hz to 2 MHz
20 mVp-p to 3.0 Vp-p into Hi-Z; 10 mVp-p to 1.5 Vp-p into 50 Ω
Gaussian
Frequency range (typical)
Amplitude range
0.1 Hz to 5 MHz
20 mVp-p to 2.5 Vp-p into Hi-Z; 10 mVp-p to 1.25 Vp-p into 50 Ω
Lorentz
Frequency range (typical)
Amplitude range
0.1 Hz to 5 MHz
20 mVp-p to 2.4 Vp-p into Hi-Z; 10 mVp-p to 1.2 Vp-p into 50 Ω
Exponential Rise / Decay
Frequency range (typical)
Amplitude range
0.1 Hz to 5 MHz
20 mVp-p to 2.5 Vp-p into Hi-Z; 10 mVp-p to 1.25 Vp-p into 50 Ω
Haversine
Frequency range (typical)
Amplitude range
0.1 Hz to 5 MHz
20 mVp-p to 2.5 Vp-p into Hi-Z; 10 mVp-p to 1.25 Vp-p into 50 Ω
Cardiac (typical)
Frequency range
Amplitude range
0.1 Hz to 500 kHz
20 mVp-p to 5 Vp-p into Hi-Z; 10 mVp-p to 2.5 Vp-p into 50 Ω
Arbitrary
Memory depth
Amplitude range
Repetition rate
Sample rate
1 to 128 k
20 mVp-p to 5 Vp-p into Hi-Z; 10 mVp-p to 2.5 Vp-p into 50 Ω
0.1 Hz to 25 MHz
250 MS/s
Frequency accuracy
Sine wave and ramp
130 ppm (frequency < 10 kHz)
50 ppm (frequency ≥ 10 kHz)
130 ppm (frequency < 10 kHz)
Square wave and pulse
50 ppm (frequency ≥ 10 kHz)
Resolution
0.1 Hz or 4 digits; whichever is larger
Amplitude accuracy
±[ (1.5% of peak-to-peak amplitude setting) + (1.5% of DC offset setting) + 1 mV ] (frequency = 1 kHz)
26 www.tek.com
Mixed Domain Oscilloscopes -- MDO3000 Series
3 – Arbitrary Function Generator
DC offset
DC offset range
DC offset resolution
Offset accuracy
±2.5 V into Hi-Z; ±1.25 V into 50 Ω
1 mV into Hi-Z; 500 uV into 50 Ω
±[(1.5% of absolute offset voltage setting) + 1 mV]; derated 3 mV for every 10 °C away from 25 °C
®
®
ArbExpress
The MDO3000 is compatible with ArbExpress PC-based signal generator waveform creation and editing software. Capture
waveforms on the MDO3000 oscilloscope and transfer them to ArbExpress for editing. Create complex waveforms in ArbExpress
and transfer them to the arbitrary function generator in the MDO3000 for output. To download ArbExpress software, go to
www.tek.com/downloads.
4 – Logic Analyzer
Vertical system digital channels
Vertical system digital channels – (Requires MDO3MSO option)
Input channels
16 digital (D15 to D0)
Thresholds
Threshold per set of 8 channels
Threshold selections
User-defined threshold range
Maximum input voltage
Threshold accuracy
Input dynamic range
Minimum voltage swing
Input resistance
TTL, CMOS, ECL, PECL, User-defined
-15 V to +25 V
-20 V to +30 V
±[100 mV + 3% of threshold setting]
50 Vp-p (threshold setting dependent)
500 mV
101 kΩ
8 pF
Probe loading
Vertical resolution
1 bit
Horizontal system digital channels
Horizontal system digital channels – (Requires MDO3MSO option)
Maximum sample rate (Main)
Maximum record length (Main)
Maximum sample rate (MagniVu)
500 MS/s (2 ns resolution)
10 M
8.25 GS/s (121.2 ps resolution)
Maximum record length (MagniVu 10k centered on the trigger
www.tek.com 27
Datasheet
Horizontal system digital channels
Minimum detectable pulse width
(typical)
2 ns
Channel-to-channel skew (typical) 500 ps
Maximum input toggle rate
250 MHz (Maximum frequency sine wave that can accurately be reproduced as a logic square wave. Requires the use of a short
ground extender on each channel. This is the maximum frequency at the minimum swing amplitude. Higher toggle rates can be
achieved with higher amplitudes.)
5 – Serial Protocol Analyzer
Automated Serial Triggering, Decode, and Search options for I2C, SPI, RS-232/422/485/UART, USB2.0, CAN, CAN FD (ISO and non-ISO), LIN, FlexRay, MIL-STD-1553,
ARINC-429, and Audio buses.
For more detailed information about serial bus support products, please see the
Serial Triggering and Analysis Application Modules datasheet.
Trigger types
I2C (optional)
Trigger on Start, Repeated Start, Stop, Missing ACK, Address (7 or 10 bit), Data, or Address and Data on I2C buses up to 10 Mb/s.
Trigger on SS active, Start of Frame, MOSI, MISO, or MOSI and MISO on SPI buses up to 50.0 Mb/s.
SPI (optional)
RS-232/422/485/UART
(optional)
Trigger on Tx Start Bit, Rx Start Bit, Tx End of Packet, Rx End of Packet, Tx Data, Rx Data, Tx Parity Error, and Rx Parity Error up
to 10 Mb/s.
USB: Low speed (optional)
USB: Full speed (optional)
CAN, CAN FD
Trigger on Sync Active, Start of Frame, Reset, Suspend, Resume, End of Packet, Token (Address) Packet, Data Packet,
Handshake Packet, Special Packet, Error.
Token packet trigger - Any token type, SOF, OUT, IN, SETUP; Address can be specified for Any Token, OUT, IN, and SETUP
token types. Address can be further specified to trigger on ≤, <, =, >, ≥, ≠ a particular value, or inside or outside of a range. Frame
number can be specified for SOF token using binary, hex, unsigned decimal and don't care digits.
Data packet trigger - Any data type, DATA0, DATA1; Data can be further specified to trigger on ≤, <, =, >, ≥, ≠ a particular data
value, or inside or outside of a range.
Handshake packet trigger - Any handshake type, ACK, NAK, STALL.
Special packet trigger - Any special type, Reserved
Error trigger - PID Check, CRC5 or CRC16, Bit Stuffing.
Trigger on Sync, Reset, Suspend, Resume, End of Packet, Token (Address) Packet, Data Packet, Handshake Packet, Special
Packet, Error.
Token packet trigger - Any token type, SOF, OUT, IN, SETUP; Address can be specified for Any Token, OUT, IN, and SETUP
token types. Address can be further specified to trigger on ≤, <, =, >, ≥, ≠ a particular value, or inside or outside of a range. Frame
number can be specified for SOF token using binary, hex, unsigned decimal and don't care digits.
Data packet trigger - Any data type, DATA0, DATA1; Data can be further specified to trigger on ≤, <, =, >, ≥, ≠ a particular data
value, or inside or outside of a range.
Handshake packet trigger - Any handshake type, ACK, NAK, STALL.
Special packet trigger - Any special type, PRE, Reserved.
Error trigger - PID Check, CRC5 or CRC16, Bit Stuffing.
Trigger on Start of Frame, Frame Type (data, remote, error, overload), Identifier (standard or extended), Data, Identifier and Data,
End of Frame, Missing ACK, or Bit Stuffing Error on CAN signals up to 1 Mb/s and on CAN FD signals up to 7 Mb/s (ISO and non
ISO).
Data can be further specified to trigger on ≤, <, =, >, ≥, or ≠ a specific data value. User-adjustable sample point is set to 50% by
default.
LIN (optional)
Trigger on Sync, Identifier, Data, Identifier and Data, Wakeup Frame, Sleep Frame, Errors such as Sync, Parity, or Checksum
Errors up to 100 kb/s (by LIN definition, 20 kb/s).
FlexRay (optional)
Trigger on Start of Frame, Type of Frame (Normal, Payload, Null, Sync, Startup), Identifier, Cycle Count, Complete Header Field,
Data, Identifier and Data, End of Frame or Errors such as Header CRC, Trailer CRC, Null Frame, Sync Frame, or Startup Frame
Errors up to 10 Mb/s.
28 www.tek.com
Mixed Domain Oscilloscopes -- MDO3000 Series
5 – Serial Protocol Analyzer
MIL-STD-1553 (optional)
Trigger on Sync, Word Type (Command, Status, Data), Command Word (set RT Address, T/R, Sub-address/Mode, Data Word
Count/Mode Code, and Parity individually), Status Word (set RT Address, Message Error, Instrumentation, Service Request Bit,
Broadcast Command Received, Busy, Subsystem Flag, Dynamic Bus Control Acceptance (DBCA), Terminal Flag, and Parity
individually), Data Word (user-specified 16-bit data value), Error (Sync, Parity, Manchester, Non-contiguous data), Idle Time
(minimum time selectable from 2 μs to 100 μs; maximum time selectable from 2 μs to 100 μs; trigger on < minimum, > maximum,
inside range, outside range). RT Address can be further specified to trigger on =, ≠, <, >, ≤, ≥ a particular value, or inside or
outside of a range.
ARINC-429 (optional)
Trigger on Word Start/End, Label, SDI, Data, Label and Data, Error conditions (any, parity, word, gap).
I2S/LJ/RJ/TDM (optional)
Trigger on Word Select, Frame Sync, or Data. Data can be further specified to trigger on ≤, <, =, >, ≥, ≠ a specific data value, or
inside or outside of a range. Maximum data rate for I2S/LJ/RJ is 12.5 Mb/s. Maximum data rate for TDM is 25 Mb/s.
6 – Digital Voltmeter
Source
Channel 1, Channel 2, Channel 3, Channel 4
Measurement types
Resolution
AC RMS, DC, AC+DC RMS (reads out in volts or amps); Frequency
ACV, DCV: 4 digits
Frequency: 5 digits
Frequency accuracy
Measuring rate
±(10 µHz/Hz + 1 count)
100 times/second; measurements updated on the display 4 times/second
Automatic adjustment of vertical settings to maximize measurement dynamic range; available for any non-trigger source
Graphical indication of minimum, maximum, current value, and five second rolling range
Vertical settings autorange
Graphical measurement
General Product Specifications
Display system
Display type
9 in. (229 mm) color display
Display resolution
Interpolation
800 horizontal × 480 vertical pixels (WVGA)
Sin(x)/x
Waveform styles
FastAcq. palettes
Graticules
Vectors, Dots, Variable Persistence, Infinite Persistence
Temperature, Spectral, Normal, Inverted
Full, Grid, Solid, Cross Hair, Frame, IRE and mV
YT, XY, and simultaneous XY/YT
Format
Maximum waveform capture rate
>280,000 wfms/s in FastAcq acquisition mode on 1 GHz models
>235,000 wfms/s in FastAcq acquisition mode on 100 MHz – 500 MHz models
>50,000 wfms/s in DPO acquisition mode on all models
www.tek.com 29
Datasheet
Input/output ports
USB 2.0 high-speed host port
Supports USB mass storage devices, printers and keyboard. One port on front and one port on rear of instrument.
USB 2.0 device port
Printing
Rear-panel connector allows for communication/control of oscilloscope through USBTMC or GPIB (with a TEK-USB-488), and
direct printing to PictBridge-compatible printers.
Print to network printer, PictBridge printer, or to a printer that supports e-mail printing. Note: This product includes software
developed by the OpenSSL Project for use in the OpenSSL Toolkit. (http://www.openssl.org/)
LAN port
RJ-45 connector, supports 10/100 Mb/s
Video out port
DB-15 female connector, connect to show the oscilloscope display on an external monitor or projector. SVGA resolution.
Auxilliary input (typical)
Front-panel BNC connector
Maximum input
(Available on two-channel models only)
Input impedance, 1 MΩ
300 VRMS CAT II with peaks ≤ ±425 V
Probe compenstor output voltage Front-panel pins
and frequency
Amplitude
Frequency
0 to 2.5 V
1 kHz
Auxiliary out
Rear-panel BNC connector
VOUT (Hi): ≥2.25 V open circuit, ≥0.9 V 50 Ω to ground
VOUT (Lo): ≤0.7 V into a load of ≤4 mA; ≤0.25 V 50 Ω to ground
Output can be configured to provide a pulse out signal when the oscilloscope triggers, a trigger signal from the internal arbitrary
function generator, or an event out for limit/mask testing.
Kensington-style lock
VESA mount
Rear-panel security slot connects to standard Kensington-style lock.
Standard (MIS-D 75) 75 mm VESA mounting points on rear of instrument.
LAN eXtensions for Instrumentation (LXI)
Class
LXI Core 2011
Version
V1.4
30 www.tek.com
Mixed Domain Oscilloscopes -- MDO3000 Series
Software
®
OpenChoice Desktop
Enables fast and easy communication between a Windows PC and your oscilloscope using USB or LAN. Transfer and save
settings, waveforms, measurements, and screen images. Word and Excel toolbars automate the transfer of acquisition data and
screen images from the oscilloscope into Word and Excel for quick reporting or further analysis.
IVI driver
Provides a standard instrument programming interface for common applications such as LabVIEW, LabWindows/CVI,
MicrosoftNET, and MATLAB.
®
e*Scope Web-based interface
Enables control of the oscilloscope over a network connection through a standard web browser. Simply enter the IP address or
network name of the oscilloscope and a web page will be served to the browser. Transfer and save settings, waveforms,
measurements, and screen images or make live control changes to settings on the oscilloscope directly from the web browser.
LXI Core 2011 Web interface
Connect to the oscilloscope through a standard Web browser by simply entering the oscilloscope IP address or network name in
the address bar of the browser. The Web interface enables viewing of instrument status and configuration, status and modification
of network settings, and instrument control through e*Scope Web-based remote control. All Web interaction conforms to LXI Core
2011 specification, version 1.4.
Power source
Power source voltage
100 to 240 V ±10%
Power source frequency
Power consumption
50 to 60 Hz at 100 to 240 V
400 Hz ±10% at 115 V
120 W maximum
Physical characteristics
Dimensions
Height
203.2 mm (8 in.)
Width
416.6 mm (16.4 in.)
147.4 mm (5.8 in.)
Depth
Weight
Net
4.2 kg (9.2 lb.)
8.6 kg (19 lb.)
Shipping
Rackmount configuration
Cooling clearance
5U
2 in. (51 mm) required on left side and rear of instrument
www.tek.com 31
Datasheet
EMC, environment, and safety
Temperature
Operating
-10 ºC to +55 ºC (+14 ºF to 131 ºF)
Nonoperating
-40 ºC to +71 ºC (-40 ºF to 160 ºF)
Humidity
Operating
Up to +40 ºC, 5% to 90% relative humidity
+40 ºC to +55 ºC, 5% to 60% relative humidity
Up to +40 ºC, 5% to 90% relative humidity
Nonoperating
Above +40 ºC up to +55 ºC, 5% to 60% relative humidity
Above +55 ºC up to +71 ºC, 5% to 40% relative humidity, non-condensing
Altitude
Operating
3,000 meters (9,843 feet)
12,000 meters (39,370 feet)
Nonoperating
Regulatory
Electromagnetic compatibility EC Council Directive 2004/108/EC
Safety
UL61010-1:2004, CAN/CSA-C22.2 No. 61010.1: 2004, Low Voltage Directive 2006/95/EC and EN61010-1:2001, IEC
61010-1:2001, ANSI 61010-1-2004, ISA 82.02.01
Random vibration
Non-operating:
Operating:
2.46 GRMS, 5-500 Hz, 10 minutes per axis, 3 axes, 30 minutes total
0.31 GRMS, 5-500 Hz, 10 minutes per axis, 3 axes, 30 minutes total
Meets IEC60068 2-64 and MIL-PRF-28800 Class 3
Shock
Operating:
50 G, 1/2 sine, 11 ms duration, 3 drops in each direction of each axis, total of 18 shocks
Meets IEC 60068 2-27 and MIL-PRF-28800 Class 3
Acoustic noise emission
Sound power level
32.0 dBA in accordance with ISO 9296
32 www.tek.com
Mixed Domain Oscilloscopes -- MDO3000 Series
Ordering information
Step 1: Choose the MDO3000 base model
MDO3000 family
MDO3012
MDO3014
MDO3022
MDO3024
MDO3032
MDO3034
MDO3052
MDO3054
MDO3102
MDO3104
Mixed Domain Oscilloscope with (2) 100 MHz analog channels, and (1) 100 MHz spectrum analyzer input
Mixed Domain Oscilloscope with (4) 100 MHz analog channels, and (1) 100 MHz spectrum analyzer input
Mixed Domain Oscilloscope with (2) 200 MHz analog channels, and (1) 200 MHz spectrum analyzer input
Mixed Domain Oscilloscope with (4) 200 MHz analog channels, and (1) 200 MHz spectrum analyzer input
Mixed Domain Oscilloscope with (2) 350 MHz analog channels, and (1) 350 MHz spectrum analyzer input
Mixed Domain Oscilloscope with (4) 350 MHz analog channels, and (1) 350 MHz spectrum analyzer input
Mixed Domain Oscilloscope with (2) 500 MHz analog channels, and (1) 500 MHz spectrum analyzer input
Mixed Domain Oscilloscope with (4) 500 MHz analog channels, and (1) 500 MHz spectrum analyzer input
Mixed Domain Oscilloscope with (2) 1 GHz analog channels, and (1) 1 GHz spectrum analyzer input
Mixed Domain Oscilloscope with (4) 1 GHz analog channels, and (1) 1 GHz spectrum analyzer input
Standard accessories
Probes
100 MHz, 200 MHz models
350 MHz, 500 MHz models
1 GHz models
TPP0250, 250 MHz bandwidth, 10X, 3.9 pF. One passive voltage probe per analog channel
TPP0500B, 500 MHz bandwidth, 10X, 3.9 pF. One passive voltage probe per analog channel
TPP1000, 1 GHz bandwidth, 10X, 3.9 pF. One passive voltage probe per analog channel
Any model with MDO3MSO option One P6316 16-channel logic probe and accessories
Accessories
103-0473-00
N-to-BNC adapter
063-4526-xx
Documentation CD
071-3249-00
Installation and Safety Instructions, printed manual (translated in English, Japanese, and Simplified Chinese)
016-2008-xx
Accessory bag
Power cord
-
-
-
®
OpenChoice Desktop Software (available on the Documentation CD and for download from www.tek.com/software/downloads.)
Calibration certificate documenting traceability to National Metrology Institute(s) and ISO9001 quality system registration
Warranty
Three-year warranty covering all parts and labor on the MDO3000 instrument. One-year warranty covering all parts and labor on included probes.
www.tek.com 33
Datasheet
Step 2: Configure your MDO3000 by adding instrument options
Instrument options
All MDO3000 Series instruments can be preconfigured from the factory with the following options:
MDO3AFG
MDO3MSO
MDO3SA
Arbitrary function generator with 13 predefined waveforms and arbitrary waveform generation
16 digital channels; includes P6316 digital probe and accessories
Increase spectrum analyzer input frequency range to 9 kHz – 3 GHz and capture bandwidth to 3 GHz.
MDO3SEC
Enhanced instrument security to enable password protected control of turning on/off all instrument ports and instrument firmware
update functionality.
Power cord and plug options
Opt. A0
Opt. A1
Opt. A2
Opt. A3
Opt. A5
Opt. A6
Opt. A10
Opt. A11
Opt. A12
Opt. A99
North America power plug (115 V, 60 Hz)
Universal Euro power plug (220 V, 50 Hz)
United Kingdom power plug (240 V, 50 Hz)
Australia power plug (240 V, 50 Hz)
Switzerland power plug (220 V, 50 Hz)
Japan power plug (100 V, 50/60 Hz)
China power plug (50 Hz)
India power plug (50 Hz)
Brazil power plug (60 Hz)
No power cord
Language options
All products are shipped with an Installation and Safety manual that is in English, Japanese, and Simplified Chinese, except instruments ordered with option L99, which
receives no printed manual. Full user manuals translated in each language listed below are included with each product in pdf format on the Documentation CD.
Opt. L0
Opt. L1
Opt. L2
Opt. L3
Opt. L4
Opt. L5
Opt. L6
Opt. L7
Opt. L8
Opt. L9
Opt. L10
Opt. L99
English front panel label
French front panel overlay
Italian front panel overlay
German front panel overlay
Spanish front panel overlay
Japanese front panel overlay
Portuguese front panel overlay
Simplified Chinese front panel overlay
Traditional Chinese front panel overlay
Korean front panel overlay
Russian front panel overlay
No manual, English front panel label
34 www.tek.com
Mixed Domain Oscilloscopes -- MDO3000 Series
Service options
Opt. C3
Calibration Service 3 Years
Opt. C5
Calibration Service 5 Years
Opt. D1
Calibration Data Report
Opt. D3
Calibration Data Report 3 Years (with Opt. C3)
Calibration Data Report 5 Years (with Opt. C5)
Opt. D5
Opt. G3
Complete Care 3 Years (includes loaner, scheduled calibration, and more)
Complete Care 5 Years (includes loaner, scheduled calibration, and more)
Repair Service 5 Years (including warranty)
Opt. G5
Opt. R5
Probes and accessories are not covered by the oscilloscope warranty and service offerings. Refer to the datasheet of each probe and accessory model for its unique warranty
and calibration terms.
Step 3: Select application modules and accessories
Application modules
Application modules are purchased as stand-alone products and can be purchased at the time of initial MDO3000 purchase or at
any future time. The optional application modules functionality is offered free for a 30-day trial period. This free trial period starts
automatically when the instrument is powered on for the first time.
Application modules have licenses which can be transferred between an application module and an oscilloscope. The license may
be contained in the module; allowing the module to be moved from one instrument to another. Or, the license can be contained in
the oscilloscope; allowing the module to be removed and stored for safekeeping. The license can be transferred back to the
module for use in another MDO3000 oscilloscope. Transferring the license to an oscilloscope and removing the module permits
the use of more than two applications simultaneously.
MDO3BND
Application module that enables all of the functionality of the MDO3AERO, MDO3AUDIO, MDO3AUTO, MDO3COMP,
MDO3EMBD, MDO3FLEX, MDO3LMT, MDO3PWR and MDO3USB application modules in a single module. Save money when
multiple serial bus debug and analysis application modules are required and easily move the entire set of functionality from one
instrument to another.
MDO3AERO
Aerospace Serial Triggering and Analysis Module. Enables triggering on packet-level information on MIL-STD-1553 and
ARINC-429 buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and
packet decode tables with time- stamp information.
Signal Inputs - Any Ch1 - Ch4, Math, Ref1 - Ref4
Recommended Probing - Differential or single ended (only one single-ended signal required)
MDO3AUDIO
MDO3AUTO
MDO3COMP
Audio Serial Triggering and Analysis Module. Enables triggering on packet-level information on I2S, LJ, RJ, and TDM audio buses
as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables
with time-stamp information.
Signal Inputs - Any Ch1 - Ch4, any D0 - D15
Recommended Probing - Single ended
Automotive Serial Triggering and Analysis Module. Enables triggering on packet-level information on CAN, CAN FD (ISO and non-
ISO), and LIN buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and
packet decode tables with time- stamp information.
Signal Inputs – CAN, CAN FD, or LIN: Any Ch1 - Ch4, any D0 - D15
Recommended Probing - CAN, CAN FD: Single ended or differential; LIN: Single ended
Computer Serial Triggering and Analysis Module. Enables triggering on packet-level information on RS-232/422/485/UART buses
as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables
with time-stamp information.
Signal Inputs - Any Ch1 - Ch4, any D0 - D15
Recommended Probing - RS-232/UART: Single ended; RS-422/485: Differential
www.tek.com 35
Datasheet
MDO3EMBD
Embedded Serial Triggering and Analysis Module. Enables triggering on packet-level information on I2C and SPI buses as well as
analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time-
stamp information.
Signal Inputs - I2C or SPI: Any Ch1 - Ch4, any D0 - D15
Recommended Probing - Single ended
MDO3FLEX
MDO3USB
FlexRay Serial Triggering and Analysis Module. Enables triggering on packet-level information on FlexRay buses as well as
analytical tools such as digital views of the signal, bus views, packet decoding, search tools, packet decode tables with time-stamp
information.
Signal Inputs - Any Ch1 - Ch4 (and any D0 - D15 when MDO3MSO option is installed; single-ended probing only)
Recommended Probing - Single ended or differential
USB Serial Triggering and Analysis Module. Enables triggering on packet-level content for low-speed, and full-speed USB serial
buses. Also enables analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet
decode tables with time-stamp information for low-speed, full-speed, and high-speed USB serial buses.
Signal Inputs - Low-speed and Full-speed: Any Ch1 - Ch4, any D0 - D15; Low-speed, Full-speed, and High-speed: Any Ch1 - Ch4,
Math, Ref1 - Ref4
Note: High-speed decode support only available on 1 GHz models.
Recommended Probing - Low-speed and Full-speed: Single ended or differential; High-speed: Differential
MDO3PWR
MDO3LMT
Power Analysis Application Module. Enables quick and accurate analysis of power quality, switching loss, harmonics, safe
operating area (SOA), modulation, ripple, and slew rate (dI/dt, dV/dt).
Limit and Mask Testing Application Module. Enables testing against limit templates generated from "golden" waveforms and mask
testing using custom masks.
Recommended accessories
Probes
Tektronix offers over 100 different probes to meet your application needs. For a comprehensive listing of available probes, please visit www.tek.com/probes.
®
TPP0250
TPP0500B
TPP0502
TPP0850
TPP1000
TAP1500
TAP2500
TAP3500
TCP0020
TCP0030A
TCP0150
TDP0500
TDP1000
TDP1500
TDP3500
THDP0200
250 MHz, 10X TekVPI passive voltage probe with 3.9 pF input capacitance
®
500 MHz, 10X TekVPI passive voltage probe with 3.9 pF input capacitance
®
500 MHz, 2X TekVPI passive voltage probe with 12.7 pF input capacitance
®
2.5 kV, 800 MHz, 50X TekVPI passive high-voltage probe
®
1 GHz, 10X TekVPI passive voltage probe with 3.9 pF input capacitance
®
1.5 GHz TekVPI active single-ended voltage probe
®
2.5 GHz TekVPI active single-ended voltage probe
®
3.5 GHz TekVPI active single-ended voltage probe
®
50 MHz TekVPI 20 Ampere AC/DC current probe
®
120 MHz TekVPI 30 Ampere AC/DC current probe
®
20 MHz TekVPI 150 Ampere AC/DC current probe
®
500 MHz TekVPI differential voltage probe with ±42 V differential input voltage
®
1 GHz TekVPI differential voltage probe with ±42 V differential input voltage
®
1.5 GHz TekVPI differential voltage probe with ±8.5 V differential input voltage
®
3.5 GHz TekVPI differential voltage probe with ±2 V differential input voltage
®
±1.5 kV, 200 MHz TekVPI high-voltage differential probe
36 www.tek.com
Mixed Domain Oscilloscopes -- MDO3000 Series
®
THDP0100
TMDP0200
±6 kV, 100 MHz TekVPI high-voltage differential probe
®
±750 V, 200 MHz TekVPI high-voltage differential probe
Accessories
TPA-N-PRE
TPA-N-VPI
Preamplifier, 12 dB nominal Gain, 9 kHz - 6 GHz
N-to-TekVPI adapter
119-4146-00
119-6609-00
077-0981-xx
TPA-BNC
Near field probe set, 100 kHz - 1 GHz
Flexible monopole antenna
Service manual (English only)
®
™
TekVPI to TekProbe BNC adapter
TekVPI Deskew pulse generator signal source
Power measurement deskew and calibration fixture
Vector Signal Analysis Software
GPIB-to-USB adapter
TEK-DPG
067-1686-xx
SignalVu-PC-SVE
TEK-USB-488
ACD3000
Soft transit case (includes front protective cover)
Hard transit case (requires ACD3000)
Rackmount kit
HCTEK4321
RMD3000
200-5052-00
Front protective cover
Other RF probes
Contact Beehive Electronics to order: http://beehive-electronics.com/probes.html
101A
EMC probe set
150A
EMC probe amplifier
Probe cable
110A
0309-0001
0309-0006
SMA probe adapter
BNC probe adapter
www.tek.com 37
Datasheet
Step 4: Add instrument upgrades in the future
Instrument upgrades
The MDO3000 Series products offer a number of ways to add functionality after the initial purchase. Listed below are the various product upgrades available and the method of
upgrade used for each product.
Free instrument options
The following options are available free of charge when the MDO3000 product is registered at www.tek.com/mdo3register.
Digital Voltmeter and
Frequency Counter
4-digit ACrms, DC, AC+DCrms voltage measurements and 5-digit frequency counter. Unique software option key provided upon
instrument registration enables the features.
Post-purchase instrument options The following products are sold as stand-alone products and can be purchased at any time to add functionality to any MDO3000
product.
MDO3AFG
MDO3MSO
MDO3SA
Add arbitrary function generator to any MDO3000 Series product.
One-time, permanent upgrade to any model enabled through single-use application module hardware key. The hardware key is
used to enable the feature and then is not required for future use.
Add 16 digital channels; includes P6316 digital probe and accessories .
One-time, permanent upgrade to any model enabled through single-use application module hardware key. The hardware key is
used to enable the feature and then is not required for future use.
Increase spectrum analyzer input frequency range to 9 kHz – 3 GHz and capture bandwidth to 3 GHz.
One-time, permanent upgrade to any model enabled through single-use application module hardware key. The hardware key is
used to enable the feature and then is not required for future use.
MDO3SEC
Add enhanced instrument security to enable password protected control of turning on/off all instrument ports and instrument
firmware update functionality.
One-time, permanent upgrade to any model enabled through software option key. Software option key products require that the
instrument model and serial number be provided at the time of purchase. The software option key is specific to the model and
serial number combination.
38 www.tek.com
Mixed Domain Oscilloscopes -- MDO3000 Series
Bandwidth upgrade options
Instrument bandwidth can be upgraded on any MDO3000 Series product after initial purchase. Each upgrade product increases
analog bandwidth and spectrum analyzer frequency range. Bandwidth upgrades are purchased based on the combination of the
current bandwidth and the desired bandwidth. Bandwidth upgrade products include new analog probes if applicable. Software
option key products depend on instrument model and serial number combination. Bandwidth upgrades up to 500 MHz can be
performed in the field, while upgrades to 1 GHz require installation at a Tektronix service center.
Model to be upgraded
Bandwidth before upgrade Bandwidth after upgrade
Order product
MDO3BW1T22
MDO3BW1T32
MDO3BW1T52
MDO3BW1T102
MDO3BW2T32
MDO3BW2T52
MDO3BW2T102
MDO3BW3T52
MDO3BW3T102
MDO3BW5T102
MDO3BW1T24
MDO3BW1T34
MDO3BW1T54
MDO3BW1T104
MDO3BW2T34
MDO3BW2T54
MDO3BW2T104
MDO3BW3T54
MDO3BW3T104
MDO3BW5T104
MDO3BW2T32
MDO3BW2T52
MDO3BW2T102
MDO3BW3T52
MDO3BW3T102
MDO3BW5T102
MDO3BW2T34
MDO3BW2T54
MDO3BW2T104
MDO3BW3T54
MDO3BW3T104
MDO3BW5T104
MDO3BW3T52
MDO3BW3T102
MDO3BW5T102
MDO3BW3T54
MDO3BW3T104
MDO3BW5T104
MDO3BW5T102
MDO3BW5T104
MDO3012
100 MHz
100 MHz
100 MHz
100 MHz
200 MHz
200 MHz
200 MHz
350 MHz
350 MHz
500 MHz
100 MHz
100 MHz
100 MHz
100 MHz
200 MHz
200 MHz
200 MHz
350 MHz
350 MHz
500 MHz
200 MHz
200 MHz
200 MHz
350 MHz
350 MHz
500 MHz
200 MHz
200 MHz
200 MHz
350 MHz
350 MHz
500 MHz
350 MHz
350 MHz
500 MHz
350 MHz
350 MHz
500 MHz
500 MHz
500 MHz
200 MHz
350 MHz
500 MHz
1 GHz
350 MHz
500 MHz
1 GHz
500 MHz
1 GHz
1 GHz
MDO3014
200 MHz
350 MHz
500 MHz
1 GHz
350 MHz
500 MHz
1 GHz
500 MHz
1 GHz
1 GHz
MDO3022
350 MHz
500 MHz
1 GHz
500 MHz
1 GHz
1 GHz
MDO3024
350 MHz
500 MHz
1 GHz
500 MHz
1 GHz
1 GHz
MDO3032
MDO3034
500 MHz
1 GHz
1 GHz
500 MHz
1 GHz
1 GHz
MDO3052
MDO3054
1 GHz
1 GHz
www.tek.com 39
Datasheet
Tektronix is registered to ISO 9001 and ISO 14001 by SRI Quality System Registrar.
Product(s) complies with IEEE Standard 488.1-1987, RS-232-C, and with Tektronix Standard Codes and Formats.
ASEAN / Australasia (65) 6356 3900
Belgium 00800 2255 4835*
Austria 00800 2255 4835*
Brazil +55 (11) 3759 7627
Balkans, Israel, South Africa and other ISE Countries +41 52 675 3777
Canada 1 800 833 9200
Central East Europe and the Baltics +41 52 675 3777
Finland +41 52 675 3777
Central Europe & Greece +41 52 675 3777
France 00800 2255 4835*
Denmark +45 80 88 1401
Germany 00800 2255 4835*
Hong Kong 400 820 5835
India 000 800 650 1835
Italy 00800 2255 4835*
Japan 81 (3) 6714 3086
Luxembourg +41 52 675 3777
The Netherlands 00800 2255 4835*
Poland +41 52 675 3777
Russia & CIS +7 (495) 6647564
Sweden 00800 2255 4835*
Mexico, Central/South America & Caribbean 52 (55) 56 04 50 90
Norway 800 16098
Portugal 80 08 12370
South Africa +41 52 675 3777
Switzerland 00800 2255 4835*
USA 1 800 833 9200
Middle East, Asia, and North Africa +41 52 675 3777
People's Republic of China 400 820 5835
Republic of Korea +822 6917 5084, 822 6917 5080
Spain 00800 2255 4835*
Taiwan 886 (2) 2656 6688
United Kingdom & Ireland 00800 2255 4835*
* European toll-free number. If not accessible, call: +41 52 675 3777
For Further Information. Tektronix maintains a comprehensive, constantly expanding collection of application notes, technical briefs and other resources to help engineers working on the cutting edge of technology. Please visit www.tek.com.
©
Copyright Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specification and
price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. All other trade names referenced are the service marks, trademarks, or registered trademarks of their respective companies.
20 Aug 2018 48W-30020-11
www.tek.com
相关型号:
©2020 ICPDF网 联系我们和版权申明