C60-X0 [TELEDYNE]

Optically Isolated 0.5 to 2.5A;
C60-X0
型号: C60-X0
厂家: TELEDYNE TECHNOLOGIES INCORPORATED    TELEDYNE TECHNOLOGIES INCORPORATED
描述:

Optically Isolated 0.5 to 2.5A

文件: 总2页 (文件大小:768K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Series C60  
Optically Isolated 0.5 to 2.5A  
Bi-Directional Solid-State Relay  
Part Number  
C60-X0  
Relay Description  
Solid-State Relay, Terminals for Through Hole Mount  
Solid-State Relay, Terminals for Surface Mount  
SC60-X0  
Add suffix 01 to denote 60Sn/40Pb Pre-Tinned Leads  
ELECTRICAL SPECIFICATIONS  
(25°C UNLESS OTHERWISE SPECIFIED)  
INPUT (CONTROL) SPECIFICATIONS (See Note 1)  
FEATURES/BENEFITS  
• Power FET Output with Very  
Low On Resistance: Virtually no  
offset with very low leakage and  
voltage drop.  
Parameter  
Min  
Max  
1.5  
50  
Units  
Vdc  
mA  
Input Voltage Drop (See Figure 1)  
Input Current (See Figure 1 and Notes 1, 7)  
1.1  
• Optical Isolation: Isolates  
control elements from load  
transients. Eliminates ground  
loops and signal ground noise.  
Input Current (Guaranteed On), (See Figure 4 and Note 7) 10  
Input Current (Guaranteed Off)  
mA  
100  
-6  
µA  
• Three Terminal Output: Output  
FETs can be paralleled  
externally to change current  
load rating.  
Reverse Voltage Protection  
Vdc  
OUTPUT (LOAD) SPECIFICATIONS (See Figure 2 And Note 2)  
• Floating Output: Allows for high  
and low side switching.  
Part Number  
DC  
Bi-Directional  
Parameter  
Min Max  
Min  
Max  
±60  
±100  
±200  
±400  
±1.25  
±0.75  
±0.50  
±0.25  
0.28  
0.7  
Units  
Vdc  
Vdc  
Vdc  
Vdc  
Adc  
Adc  
Adc  
Adc  
Ohm  
Ohm  
Ohm  
Ohm  
µAdc  
ms  
• Switches High Voltages and  
Currents: Voltages to 400 Vdc.  
Current to 2.5 Adc.  
Output Voltage Rating C60-10  
60  
C60-20  
100  
200  
400  
2.5  
1.5  
1.0  
0.5  
0.07  
0.2  
0.45  
1.0  
2.0  
4.0  
Bi-directional, DC or AC.  
C60-30  
• High Noise Immunity: Control  
circuit cannot be triggered by  
output switching noise.  
C60-40  
Output Current Rating C60-10  
• 6-Pin Mini-DIP Package:  
Standard or surface mount  
available.  
C60-20  
C60-30  
C60-40  
DESCRIPTION  
The Series C60 solid-state relay is  
an advanced design capable of  
switching very heavy loads in a  
physically small 6-pin mini DIP  
package. These relays have a  
power FET output that ensures low  
On resistance, no offset voltage  
and low leakage current. They are  
versatile and can be used to switch  
AC, Bi-directional or DC loads.  
Optical isolation ensures complete  
protection of signal lines, power  
and ground bus and control circuits  
from switching noise and EMI.  
On Resistance  
(See Note 6)  
C60-10  
C60-20  
C60-30  
C60-40  
1.8  
4.0  
Leakage Current at Rated Voltage  
Turn-On Time @ 10mA C60-10  
(See Figure 4 and Note 7)  
1.0  
4.0  
C60-20,-30,-40  
3.0  
3.0  
ms  
Turn-Off Time  
C60-10  
C60-20,-30,-40  
C60-10  
C60-20  
C60-30  
C60-40  
109  
4.0  
4.0  
ms  
3.0  
3.0  
ms  
Output Capacitance  
1000  
500  
400  
400  
500  
250  
200  
200  
pf  
pf  
pf  
BLOCK DIAGRAM  
pf  
Isolation (Input to Output)  
Dielectric Strength  
109  
1500  
Ohms  
Vrms  
pF  
1500  
Capacitance (Input to Output)  
Junction Temperature (TJ)  
3.0  
3.0  
125  
25  
125  
°C  
Junction to Case Thermal Resistance  
Case to Ambient Thermal Resistance  
°C  
75  
°C/W  
© 2010 TELEDYNE RELAYS  
(800) 284-7007 • www.teledynerelays.com  
C60 1  
2DSC60-X0 Rev --  
Series C60  
CHARACTERISTIC CURVES  
MECHANICAL SPECIFICATION  
WIRING CONFIGURATIONS  
NOTES:  
1. Series resistor is required to limit input current to  
50 mA maximum.  
2. The input current is 10 mA for all tests unless  
otherwise specified.  
3. The surge current is non-repetitive for a  
maximum duration of 20 ms (See Figure 3).  
• Operating Temperature Range: -40°C to 85°C  
• Storage Temperature Range: -40°C to 100°C  
• Weight: 1 gm. maximum  
4. Loads may be connected to positive or negative  
referenced power supplies. Inductive loads must  
be diode suppressed.  
• Case: 6 pin dual in line, filled epoxy  
5. Continuous load current is rated under the  
conditions of still air and mounted on a printed  
circuit board.  
6. To calculate ON Resistance for a given junction  
using the  
temperature calculate the new R  
equation shown below:  
On  
0.006(T -25°C)  
x e  
On (25°C)  
R
=R  
J
7. Turn on Time can be controlled with input control  
current. Calculate a new turn-on time:  
t
=(t  
)(10mA/I )  
8. Load voltage rating should be derated 10% at  
On Specification Limit  
In  
-40°C  
C60 2  
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE  
© 2010 TELEDYNE RELAYS  
2DSC60-X0 Rev --  

相关型号:

C600

500 WATTS (AC) DC/D CSINGLE OUTPUT
POWERBOX

C6000RU

Isolated, 60W Ultra-Wide 4:1Input DC/DC Converters
MPD

C6001

BROADBAND: RF & WIRELESS
PULSE

C6001AT

Clock Generator, CMOS, PDSO16, TSSOP-16
CYPRESS

C6001L

BROADBAND: RF & WIRELESS
PULSE

C6001RU

Isolated, 60W Ultra-Wide 4:1Input DC/DC Converters
MPD

C6002-601

Strip Terminal Block, 25A, 1 Row(s), 1 Deck(s)
MOLEX

C6002-L

Strip Terminal Block, 25A, 1 Row(s), 1 Deck(s)
MOLEX

C6002601

STRIP TERMINAL BLOCK
MOLEX

C6002RU

Isolated, 60W Ultra-Wide 4:1Input DC/DC Converters
MPD

C6003

Strip Terminal Block, 25A, 1 Row(s), 1 Deck(s)
MOLEX

C6003-10A

Strip Terminal Block, 25A, 1 Row(s), 1 Deck(s)
MOLEX