CRS-33SXC-DMS [TELEDYNE]
Failsafe 2P3T Coaxial Switch;型号: | CRS-33SXC-DMS |
厂家: | TELEDYNE TECHNOLOGIES INCORPORATED |
描述: | Failsafe 2P3T Coaxial Switch |
文件: | 总8页 (文件大小:692K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Series CCRS-33S/CRS-33S
Miniature DC–18 GHz
COAX SWITCHES
Failsafe 2P3T Coaxial Switch
PART NUMBER DESCRIPTION
CCRS-33S
CRS-33S
Commercial Failsafe 2P3T, DC-18GHz
Elite Failsafe 2P3T, DC-18GHz
The CCRS-33S/CRS-33S is a broadband, 2P3T, electromechanical coaxial switch designed to switch a
microwave signal from a common input to either of two outputs. The characteristic
impedance is 50 Ohms. The switches are small with the minimum spacing that is compatible with SMA
connectors, and can also be used as a SPDT switch with external terminations.
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS
ELECTRICAL CHARACTERISTICS
Operating Temperature
Form Factor
2P3T,
Commercial Model, CCRS-33S
Elite Model, CRS-33S
–40°C to 65°C
–55°C to 85°C
break before make
Frequency Range
CCRS-33S
CRS-33S
Vibration (MIL-STD-202 Method 214,
Condition D, non-operating)
10 g’s RMS
DC–18 GHz
DC–18 GHz
Shock (MIL-STD-202 Method 213,
Condition D, non-operating)
500 g’s
Characteristic Impedance
Operate Time
50 Ohms
10 ms (max.)
10 ms (max.)
12 15 24 28
Standard Actuator Life
Actuator Life w/ Additional Features
5,000,000 cycles
1,000,000 cycles
Release Time
Actuation Voltage Available
Actuation Current, max. @ ambient
V
Connector Type
Humidity (Moisture Seal)
Weight
SMA
420 350 280 200 mA
Available
2.65 oz. (75.1g) (max.)
PERFORMANCE CHARACTERISTICS
Frequency
DC–6 GHz
0.1
6–12 GHz
12–18 GHz
Insertion Loss, dB,
max.
0.2
0.3
Isolation, dB, min.
VSWR , max.
85
80
75
1.1:1
1.2:1
1.3:1
PART NUMBERING SYSTEM
CCRS-33
S
1
C
-
T **
Series
Options
Connectors
Actuator Voltage
Actuator Type
Connector
S: SMA Female
Actuator Voltage
Actuator Type
O: Standard Contacts
C: Indicator Contacts
Options
1: 28 Vdc Failsafe
2: 15 Vdc Failsafe
3: 12 Vdc Failsafe
4: 24 Vdc Failsafe
T: TTL Drivers with Diodes
D: Transient Suppression
Diodes
M: Moisture Seal
**SEE PARTS LIST ON PAGE 8
S: 9 Pin D-Sub Connector
For other options, contact factory.
© 2012 TELEDYNE RELAYS
(800) 284-7007 • www.teledynecoax.com
CCRS-33S/CRS-33S Page 1
CCRS-33S\CRS-33S\062012\Q2
Series CCRS-33S/CRS-33S
Miniature DC–18 GHz
Failsafe 2P3T Coaxial Switch
COAX SWITCHES
SCHEMATICS AND MECHANICAL OUTLINE
2X SOLDER TERMINALS
SOLDER WIRE MAXIMUM
TEMP 250ºC FOR NO
MORE THAN 5 SEC
H = 1.75 STD & Indicator Model
H = 1.90 All OTHER Models
Indicators
Analog
TTL
1
6
“-S OPTION” 9-PIN D-SUB CONNECTOR (EXAMPLE: CCRS-33S10-S)
9 PIN D-SUB PINOUT FOR FAILSAFE 2P3T
TRUTH TABLE (with TTL option)
OPTIONS
Logic
Input
Indicator
(if applicable)
RF Path
Pin
No.
1
Indicators &
TTL
Basic
Indicators
TTL
1
0
1
+
-
+
-
2&3
1&2
4&5
3&4
B & C
A & C
2
3
4
Common
1
Common
1
5
6
7
8
9
Vsw
Vsw
A
B
A
B
C
C
CCRS-33S/CRS-33S Page 2
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2012 TELEDYNE COAX SWITCHES
CCRS-33S\CRS-33S\062012\Q2
Series CCRS-33S/CRS-33S
Miniature DC–18 GHz
COAX SWITCHES
Failsafe 2P3T Coaxial Switch
TYPICAL NARROWBAND RF INSERTION LOSS PERFORMANCE CURVES
Insertion Loss ( DC-6 GHz )
Insertion Loss ( 6-12 GHz )
0.0
-0.1
-0.2
-0.3
-0.4
-0.5
-0.6
-0.7
-0.8
-0.9
-1.0
0.0
-0.1
-0.2
-0.3
-0.4
-0.5
-0.6
-0.7
-0.8
-0.9
-1.0
0
1
2
3
4
5
6
6
7
8
9
10
11
12
Frequency(GHz)
Frequency(GHz)
Insertion Loss ( 12-18 GHz )
0.0
-0.1
-0.2
-0.3
-0.4
-0.5
-0.6
-0.7
-0.8
-0.9
-1.0
12
13
14
15
16
17
18
Frequency(GHz)
RF NOTES
© 2012 TELEDYNE RELAYS
(800) 284-7007 • www.teledynecoax.com
CCRS-33S/CRS-33S Page 3
CCRS-33S\CRS-33S\062012\Q2
Series CCRS-33S/CRS-33S
Miniature DC–18 GHz
Failsafe 2P3T Coaxial Switch
COAX SWITCHES
TYPICAL NARROWBAND RF ISOLATION PERFORMANCE CURVES
Isolation ( DC-6 GHz )
0
Isolation ( 6-12 GHz )
0
-20
-20
-40
-40
-60
-60
-80
-80
-100
-120
-140
-100
-120
-140
0
1
2
3
4
5
6
6
7
8
9
10
11
12
Frequency(GHz)
Frequency(GHz)
Isolation ( 12-18 GHz )
0
-20
-40
-60
-80
-100
-120
-140
12
13
14
15
16
17
18
Frequency(GHz)
RF NOTES
CCRS-33S/CRS-33S Page 4
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2012 TELEDYNE COAX SWITCHES
CCRS-33S\CRS-33S\062012\Q2
Series CCRS-33S/CRS-33S
Miniature DC–18 GHz
COAX SWITCHES
Failsafe 2P3T Coaxial Switch
TYPICAL NARROWBAND RF VSWR PERFORMANCE CURVES
VSWR ( DC-6 GHz )
2.0
VSWR ( 6-12 GHz )
2.0
1.9
1.8
1.7
1.6
1.5
1.4
1.3
1.2
1.1
1.0
1.9
1.8
1.7
1.6
1.5
1.4
1.3
1.2
1.1
1.0
0
1
2
3
4
5
6
6
7
8
9
10
11
12
Frequency(GHz)
Frequency(GHz)
VSWR ( 12-18 GHz )
2.0
1.9
1.8
1.7
1.6
1.5
1.4
1.3
1.2
1.1
1.0
12
13
14
15
16
17
18
Frequency(GHz)
RF NOTES
© 2012 TELEDYNE RELAYS
(800) 284-7007 • www.teledynecoax.com
CCRS-33S/CRS-33S Page 5
CCRS-33S\CRS-33S\062012\Q2
Series CCRS-33S/CRS-33S
Miniature DC–18 GHz
Failsafe 2P3T Coaxial Switch
COAX SWITCHES
TYPICAL POWER PERFORMANCE CURVE
Power Handling vs. Frequency
3000
2000
1000
800
600
400
300
200
100
80
60
40
30
20
10
.1
.2 .3 .4 .6 .8 1
2
4
6 8 10
18
Frequency GHz
Estimates based on the following reference conditions:
• Ambient temperature of 40°C or less
• Sea level operation
• Load VSWR of 1.20:1 maximum
• No high-power (hot) switching
Please contact Teledyne Coax Switches for derating factors when applications do not meet the foregoing reference conditions.
CCRS-33S/CRS-33S Page 6
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2012 TELEDYNE COAX SWITCHES
CCRS-33S\CRS-33S\062012\Q2
Series CCRS-33S/CRS-33S
Miniature DC–18 GHz
COAX SWITCHES
Failsafe 2P3T Coaxial Switch
GLOSSARY
Actuator
Performance Parameters vs Frequency
An actuator is the electromechanical mechanism that Generally speaking, the RF performance of coaxial switches
transfers the RF contacts from one position to another upon is frequency dependent. With increasing frequency, VSWR
DC command.
and insertion loss increase while isolation decreases. All
data sheets specify these three parameters as “worst case”
at the highest operating frequency. If the switch is to be
Arc Suppression Diode
A diode is connected in parallel with the coil. This diode used over a narrow frequency band, better performance
limits the “reverse EMF spike” generated when the coil de- can be achieved.
energizes to 0.7 volts. The diode cathode is connected to
the positive side of the coil and the anode is connected to Actuator Current vs Temperature
the negative side.
The resistance of the actuator coil varies as a function of
temperature. There is an inverse relationship between the
operating temperature of the switch and the actuator drive
Date Code
All switches are marked with either a unique serial number current. For switches operating at 28 VDC, the approximate
or a date code. Date codes are in accordance with MIL- actuator drive current at temperature, T, can be calculated
STD-1285 Paragraph 5.2.5 and consist of four digits. using the equation:
The first two digits define the year and the last two digits
define the week of the year (YYWW). Thus, 1032 identifies
switches that passed through final inspection during the
32nd week of 2010.
I
A
I
=
T
[1 + .00385 (T-20)]
Where:
Failsafe
A failsafe switch reverts to the default or failsafe position
when actuating voltage is removed. This is realized by a
return spring within the drive mechanism. This type of switch
requires the continuous application of operating voltage to
select and hold any position. (Multi-position switches are
normally open with no voltage applied).
I
I
=
=
Actuator current at temperature, T
T
Room temperature actuator current –
see data sheet
A
T
=
Temperature of interest in °C
Indicator
Magnetic Sensitivity
Indicators tell the system which position the switch is in. An electro-mechanical switch can be sensitive to ferrous
Other names for indicators are telemetry contacts or tellback materials and external magnetic fields. Neighboring ferrous
circuit. Indicators are usually a set of internally mounted DC materials should be permitted no closer than 0.5 inches and
contacts linked to the actuator. They can be wired to digital adjacent external magnetic fields should be limited to a flux
input lines, status lights, or interlocks. Unless otherwise density of less than 5 Gauss.
specified, the maximum indicator contact rating is 30 Vdc,
50 mA, or 1.5 Watts into a resistive load.
Isolation
Isolation is the measure of the power level at the output
connector of an unconnected RF channel as referenced to
the power at the input connector. It is specified in dB below
the input power level.
Switching Time
Switching time is the total interval beginning with the arrival
of the leading edge of the command pulse at the switch DC
input and ending with the completion of the switch transfer,
including contact bounce. It consists of three parts: (1)
inductive delay in the coil, (2) transfer time of the physical
movement of the contacts, and (3) the bounce time of the
RF contacts.
TTL Switch Driver Option
As a special option, switch drivers can be provided for both
failsafe and latching switches, which are compatible with
industry-standard low-power Schottky TTL circuits.
© 2012 TELEDYNE RELAYS
(800) 284-7007 • www.teledynecoax.com
CCRS-33S/CRS-33S Page 7
CCRS-33S\CRS-33S\062012\Q2
Series CCRS-33S/CRS-33S
Miniature DC–18 GHz
Failsafe 2P3T Coaxial Switch
COAX SWITCHES
FAILSAFE CCRS-33S/CRS-33S PART NUMBER LIST
PART NO.
PART NO.
1
CCRS-33SXC
43
44
45
46
47
48
CRS-33SXO-MS
CRS-33SXO-S
CRS-33SXO-T
CRS-33SXO-TM
CRS-33SXO-TMS
CRS-33SXO-TS
2
CCRS-33SXC-D
CCRS-33SXC-DM
CCRS-33SXC-DMS
CCRS-33SXC-DS
CCRS-33SXC-M
CCRS-33SXC-MS
CCRS-33SXC-S
CCRS-33SXC-T
CCRS-33SXC-TM
CCRS-33SXC-TMS
CCRS-33SXC-TS
CCRS-33SXO
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
CCRS-33SXO-D
CCRS-33SXO-DM
CCRS-33SXO-DMS
CCRS-33SXO-DS
CCRS-33SXO-M
CCRS-33SXO-MS
CCRS-33SXO-S
CCRS-33SXO-T
CCRS-33SXO-TM
CCRS-33SXO-TMS
CCRS-33SXO-TS
CRS-33SXC
CRS-33SXC-D
CRS-33SXC-DM
CRS-33SXC-DMS
CRS-33SXC-DS
CRS-33SXC-M
CRS-33SXC-MS
CRS-33SXC-S
CRS-33SXC-T
CRS-33SXC-TM
CRS-33SXC-TMS
CRS-33SXC-TS
CRS-33SXO
CRS-33SXO-D
CRS-33SXO-DM
CRS-33SXO-DMS
CRS-33SXO-DS
CRS-33SXO-M
*
X = 1 (28Vdc), 2 (15Vdc), 3 (12Vdc) and 4 (24Vdc)
CCRS-33S/CRS-33S Page 8 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2012 TELEDYNE COAX SWITCHES
CCRS-33S\CRS-33S\062012\Q2
相关型号: