CRT-53SXC-RMS [TELEDYNE]
Failsafe SPDT Coaxial Switch;型号: | CRT-53SXC-RMS |
厂家: | TELEDYNE TECHNOLOGIES INCORPORATED |
描述: | Failsafe SPDT Coaxial Switch 光电二极管 |
文件: | 总8页 (文件大小:597K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Series CCRT-53S/CRT-53S
Internal 50Ω Termination DC-26.5 GHz
Failsafe SPDT Coaxial Switch
COAX SWITCHES
PART NUMBER DESCRIPTION
CCRT-53S
CRT-53S
Commercial Failsafe SPDT, DC-26.5GHz, Internal 50Ω Termination
Elite Failsafe SPDT, DC-26.5GHz, Internal 50Ω Termination
The CCRT-53S/CRT-53S is an internally terminated, broadband, SPDT, electromechanical coaxial switch
designed to switch a microwave signal from a common input to either of two outputs. The characteristic
impedance is 50 Ohms. Internal terminations provide an impedance match for the unselected port. The
switches are small with the minimum spacing that is compatible with SMA connectors.
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS
ELECTRICAL CHARACTERISTICS
Operating Temperature
Form Factor
SPDT,
Commercial Model, CCRT-53S
Elite Model, CRT-53S
–40°C to 65°C
–55°C to 85°C
break before make
Frequency Range
CCRT-53S
CRT-53S
Vibration (MIL-STD-202 Method 214,
Condition D, non-operating)
10 g’s RMS
DC–26.5 GHz
DC–26.5 GHz
Shock (MIL-STD-202 Method 213,
Condition D, non-operating)
500 g’s
Characteristic Impedance
Terminations
50 Ohms
50Ω, 2 Watts CW max.
10 ms (max.)
Standard Actuator Life
Actuator Life w/ Additional Features
5,000,000 cycles
1,000,000 cycles
Operate Time
Release Time
10 ms (max.)
Connector Type
Humidity (Moisture Seal)
Weight
SMA
Actuation Voltage Available
Actuation Current, max. @ ambient
12 15 24 28 V
Available
420 350 280 200 mA
2.65 oz. (75.13g) (max.)
PERFORMANCE CHARACTERISTICS
Frequency
DC–6 GHz
6–12 GHz
12–18 GHz
18–22 GHz
22–26.5 GHz
Insertion Loss, dB,
max.
0.2
0.3
0.4
0.5
0.6
Isolation, dB, min.
VSWR , max.
80
75
70
70
55
1.1:1
1.2:1
1.3:1
1.5:1
1.6:1
PART NUMBERING SYSTEM
CCRT-53
S
1
C
-
T **
Series
Options
Actuator Type
Connectors
Actuator Voltage
Connector
S: SMA Female
Actuator Voltage
Actuator Type
0: Standard Contacts
C: Indicator Contacts
Options
1: 28 Vdc Failsafe
2: 15 Vdc Failsafe
3: 12 Vdc Failsafe
4: 24 Vdc Failsafe
T: TTL Drivers with Diodes
D: Transient Suppression
Diodes
M: Moisture Seal
**SEE PARTS LIST ON PAGE 8
S: 9 Pin D-Sub Connector
For other options, contact factory.
© 2013 TELEDYNE RELAYS
(800) 284-7007 • www.teledynecoax.com
CCRT-53S/CRT-53S Page 1
CCRT-53S\CRT-53S\082013\Q3
Series CCRT-53S/CRT-53S
Internal 50Ω Termination DC-26.5 GHz
Failsafe SPDT Coaxial Switch
COAX SWITCHES
SCHEMATICS AND MECHANICAL OUTLINE
H = 1.75 MAX. STD & Indicator Model
H = 1.90 MAX. TTL Model
H = 2.05 MAX. 9-Pin D-Sub Model
Indicators
TTL
Analog
1
6
“-S OPTION” 9-PIN D-SUB CONNECTOR (EXAMPLE: CCRT-53S10-S)
9 PIN D-SUB PINOUT FOR FAILSAFE SPDT
TRUTH TABLE (with TTL option)
OPTIONS
Logic
Input
Indicator
(if applicable)
RF Path
Pin
No.
1
Indicators &
TTL
Basic
Indicators
TTL
1
IN
IN
A
B
+
-
+
-
to 1
to 2
2
Terminated
0
1
On
C
0
0
3
4
Common
1
Common
1
Terminated
On
C
5
6
7
8
9
Vsw
Vsw
A
B
A
B
C
C
CCRT-53S/CRT-53S Page 2
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2013 TELEDYNE COAX SWITCHES
CCRT-53S\CRT-53S\082013\Q3
Series CCRT-53S/CRT-53S
Internal 50Ω Termination DC-26.5 GHz
Failsafe SPDT Coaxial Switch
COAX SWITCHES
TYPICAL NARROWBAND RF INSERTION LOSS PERFORMANCE CURVES
Insertion Loss ( DC-6 GHz )
Insertion Loss ( 6-12 GHz )
0.0
-0.1
-0.2
-0.3
-0.4
-0.5
-0.6
-0.7
-0.8
-0.9
-1.0
0.0
-0.1
-0.2
-0.3
-0.4
-0.5
-0.6
-0.7
-0.8
-0.9
-1.0
0
1
2
3
4
5
6
6
7
8
9
10
11
12
Frequency(GHz)
Frequency(GHz)
Insertion Loss ( 12-18 GHz )
Insertion Loss ( 18-22 GHz )
0.0
-0.1
-0.2
-0.3
-0.4
-0.5
-0.6
-0.7
-0.8
-0.9
-1.0
0.0
-0.1
-0.2
-0.3
-0.4
-0.5
-0.6
-0.7
-0.8
-0.9
-1.0
12
13
14
15
16
17
18
18
19
20
21
22
Frequency(GHz)
Frequency(GHz)
Insertion Loss ( 22-26.5 GHz )
0.0
-0.1
-0.2
-0.3
-0.4
-0.5
-0.6
-0.7
-0.8
-0.9
-1.0
22
23
24
25
26
Frequency(GHz)
RF NOTES
© 2013 TELEDYNE RELAYS
(800) 284-7007 • www.teledynecoax.com
CCRT-53S/CRT-53S Page 3
CCRT-53S\CRT-53S\082013\Q3
Series CCRT-53S/CRT-53S
Internal 50Ω Termination DC-26.5 GHz
Failsafe SPDT Coaxial Switch
COAX SWITCHES
TYPICAL NARROWBAND RF ISOLATION PERFORMANCE CURVES
Isolation ( DC-6 GHz )
0
Isolation ( 6-12 GHz )
0
-20
-20
-40
-40
-60
-60
-80
-80
-100
-120
-140
-100
-120
-140
0
1
2
3
4
5
6
6
7
8
9
10
11
12
Frequency(GHz)
Frequency(GHz)
Isolation ( 12-18 GHz )
Isolation ( 18-22 GHz )
0
-20
0
-20
-40
-40
-60
-60
-80
-80
-100
-120
-140
-100
-120
-140
12
13
14
15
16
17
18
18
18.5
19
19.5
20
20.5
21
21.5
22
Frequency(GHz)
Frequency(GHz)
Isolation ( 22-26.5 GHz )
0
-20
-40
-60
-80
-100
-120
-140
22
22.5
23
23.5
24
24.5
25
25.5
26
26.5
Frequency(GHz)
RF NOTES
CCRT-53S/CRT-53S Page 4
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2013 TELEDYNE COAX SWITCHES
CCRT-53S\CRT-53S\082013\Q3
Series CCRT-53S/CRT-53S
Internal 50Ω Termination DC-26.5 GHz
Failsafe SPDT Coaxial Switch
COAX SWITCHES
TYPICAL NARROWBAND RF VSWR PERFORMANCE CURVES
VSWR ( DC-6 GHz )
2.0
VSWR ( 6-12 GHz )
2.0
1.9
1.8
1.7
1.6
1.5
1.4
1.3
1.2
1.1
1.0
1.9
1.8
1.7
1.6
1.5
1.4
1.3
1.2
1.1
1.0
0
1
2
3
4
5
6
6
7
8
9
10
11
12
Frequency(GHz)
Frequency(GHz)
VSWR ( 12-18 GHz )
VSWR ( 18-22 GHz )
2.0
1.9
1.8
1.7
1.6
1.5
1.4
1.3
1.2
1.1
1.0
2.0
1.9
1.8
1.7
1.6
1.5
1.4
1.3
1.2
1.1
1.0
12
13
14
15
16
17
18
18
18.5
19
19.5
20
20.5
21
21.5
22
Frequency(GHz)
Frequency(GHz)
VSWR ( 22-26.5 GHz )
2.0
1.9
1.8
1.7
1.6
1.5
1.4
1.3
1.2
1.1
1.0
22
22.5
23
23.5
24
24.5
25
25.5
26
26.5
Frequency(GHz)
RF NOTES
© 2013 TELEDYNE RELAYS
(800) 284-7007 • www.teledynecoax.com
CCRT-53S/CRT-53S Page 5
CCRT-53S\CRT-53S\082013\Q3
Series CCRT-53S/CRT-53S
Internal 50Ω Termination DC-26.5 GHz
Failsafe SPDT Coaxial Switch
COAX SWITCHES
TYPICAL POWER PERFORMANCE CURVE
Power Handling vs. Frequency
3000
2000
1000
800
600
400
300
200
100
80
60
40
30
20
10
.1
.2 .3 .4 .6 .8 1
2
4
6 8 10
18 26.5
Frequency GHz
Estimates based on the following reference conditions:
• Ambient temperature of 40°C or less
• Sea level operation
• Load VSWR of 1.20:1 maximum
• No high-power (hot) switching
Please contact Teledyne Coax Switches for derating factors when applications do not meet the foregoing reference conditions.
CCRT-53S/CRT-53S Page 6
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2013 TELEDYNE COAX SWITCHES
CCRT-53S\CRT-53S\082013\Q3
Series CCRT-53S/CRT-53S
Internal 50Ω Termination DC-26.5 GHz
Failsafe SPDT Coaxial Switch
COAX SWITCHES
GLOSSARY
Actuator
including contact bounce. It consists of three parts: (1)
An actuator is the electromechanical mechanism that inductive delay in the coil, (2) transfer time of the physical
transfers the RF contacts from one position to another upon movement of the contacts, and (3) the bounce time of the
DC command.
RF contacts.
Arc Suppression Diode
TTL Switch Driver Option
A diode is connected in parallel with the coil. This diode As a special option, switch drivers can be provided for both
limits the “reverse EMF spike” generated when the coil de- failsafe and latching switches, which are compatible with
energizes to 0.7 volts. The diode cathode is connected to industry-standard low-power Schottky TTL circuits.
the positive side of the coil and the anode is connected to
the negative side.
Performance Parameters vs Frequency
Generally speaking, the RF performance of coaxial switches
is frequency dependent. With increasing frequency, VSWR
Date Code
All switches are marked with either a unique serial number and insertion loss increase while isolation decreases. All
or a date code. Date codes are in accordance with MIL- data sheets specify these three parameters as “worst case”
STD-1285 Paragraph 5.2.5 and consist of four digits. at the highest operating frequency. If the switch is to be
The first two digits define the year and the last two digits used over a narrow frequency band, better performance
define the week of the year (YYWW). Thus, 1032 identifies can be achieved.
switches that passed through final inspection during the
32nd week of 2010.
Actuator Current vs Temperature
The resistance of the actuator coil varies as a function of
temperature. There is an inverse relationship between the
Failsafe
A failsafe switch reverts to the default or failsafe position operating temperature of the switch and the actuator drive
when actuating voltage is removed. This is realized by a current. For switches operating at 28 VDC, the approximate
return spring within the drive mechanism. This type of switch actuator drive current at temperature, T, can be calculated
requires the continuous application of operating voltage to using the equation:
I
A
select and hold any position. (Multi-position switches are
normally open with no voltage applied).
I
=
T
[1 + .00385 (T-20)]
Where:
Indicator
Indicators tell the system which position the switch is in.
Other names for indicators are telemetry contacts or tellback
circuit. Indicators are usually a set of internally mounted DC
contacts linked to the actuator. They can be wired to digital
input lines, status lights, or interlocks. Unless otherwise
specified, the maximum indicator contact rating is 30 Vdc,
50 mA, or 1.5 Watts into a resistive load.
I
I
=
=
Actuator current at temperature, T
T
Room temperature actuator current –
see data sheet
A
T
=
Temperature of interest in °C
Magnetic Sensitivity
An electro-mechanical switch can be sensitive to ferrous
materials and external magnetic fields. Neighboring ferrous
Internal Termination
Unselected ports are internally terminated to a matched materials should be permitted no closer than 0.5 inches and
load. The load is 50Ω resistive device. The max RF power adjacent external magnetic fields should be limited to a flux
rating is 2 Watts CW. Without the internal termination option, density of less than 5 Gauss.
the unselected ports are open circuits.
SPECIAL FEATURE
Isolation
Switching High-Power or Highly Sensitive Signals
Ensure the most linear response with the best galvanically
matched contact system in the industry. Extremely low
passive intermodulation is standard on all of our switches.
Isolation is the measure of the power level at the output
connector of an unconnected RF channel as referenced to
the power at the input connector. It is specified in dB below
the input power level.
Carrier
Frequency 1
Carrier
Frequency 2
PIM 3rd Order
Frequency
PIM 5th
Order Fre-
quency
SPDT Switch
A single-pole double-throw, bi-directional switch that can
be used as having one input and two outputs or two inputs
and one output.
870 MHz
SPDT
893 MHz
847 MHz
824 MHz
3rd Order
Intermodulation
5th Order
Intermodulation
Switching Time
Switching time is the total interval beginning with the arrival
of the leading edge of the command pulse at the switch DC
input and ending with the completion of the switch transfer,
–91 dBm
–110 dBm
–134 dBc
–153 dBc
© 2013 TELEDYNE RELAYS
(800) 284-7007 • www.teledynecoax.com
CCRT-53S/CRT-53S Page 7
CCRT-53S\CRT-53S\082013\Q3
Series CCRT-53S/CRT-53S
Internal 50Ω Termination DC-26.5 GHz
Failsafe SPDT Coaxial Switch
COAX SWITCHES
FAILSAFE CCRT-53S/CRT-53S PART NUMBER LIST
PART NO.
PART NO.
PART NO.
1
CCRT-53SXC
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
CCRT-53SX0
85
CRT-53SXD-MS
CRT-53SXD-R
CRT-53SXD-RM
CRT-53SXD-RMS
CRT-53SXD-RS
CRT-53SXD-S
CRT-53SXD-T
CRT-53SXD-TM
CRT-53SXD-TMS
CRT-53SXE
2
CCRT-53SXC-D
CCRT-53SXC-DM
CCRT-53SXC-DMS
CCRT-53SXC-DR
CCRT-53SXC-DRM
CCRT-53SXC-DRMS
CCRT-53SXC-DRS
CCRT-53SXC-DS
CCRT-53SXC-M
CCRT-53SXC-MS
CCRT-53SXC-R
CCRT-53SXC-RM
CCRT-53SXC-RMS
CCRT-53SXC-RS
CCRT-53SXC-S
CCRT-53SXC-T
CCRT-53SXC-TM
CCRT-53SXC-TMS
CCRT-53SXC-TS
CCRT-53SXD
CCRT-53SX0-D
CCRT-53SX0-DM
CCRT-53SX0-DMS
CCRT-53SX0-DR
CCRT-53SX0-DRM
CCRT-53SX0-DRMS
CCRT-53SX0-DRS
CCRT-53SX0-DS
CCRT-53SX0-M
CCRT-53SX0-MS
CCRT-53SX0-R
CCRT-53SX0-RM
CCRT-53SX0-RMS
CCRT-53SX0-RS
CCRT-53SX0-S
CCRT-53SX0-T
CCRT-53SX0-TM
CCRT-53SX0-TMS
CCRT-53SX0-TS
CRT-53SXC
86
3
87
4
88
5
89
6
90
7
91
8
92
9
93
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
94
95
CRT-53SXE-M
CRT-53SXE-MS
CRT-53SXE-R
CRT-53SXE-RM
CRT-53SXE-RMS
CRT-53SXE-RS
CRT-53SXE-S
CRT-53SXE-T
CRT-53SXE-TM
CRT-53SXE-TMS
CRT-53SX0
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
CCRT-53SXD-M
CCRT-53SXD-MS
CCRT-53SXD-R
CCRT-53SXD-RM
CCRT-53SXD-RMS
CCRT-53SXD-RS
CCRT-53SXD-S
CCRT-53SXD-T
CCRT-53SXD-TM
CCRT-53SXD-TMS
CCRT-53SXE
CRT-53SXC-D
CRT-53SX0-D
CRT-53SX0-DM
CRT-53SX0-DMS
CRT-53SX0-DR
CRT-53SX0-DRM
CRT-53SX0-DRMS
CRT-53SX0-DRS
CRT-53SX0-DS
CRT-53SX0-M
CRT-53SX0-MS
CRT-53SX0-R
CRT-53SX0-RM
CRT-53SX0-RMS
CRT-53SX0-RS
CRT-53SX0-S
CRT-53SXC-DM
CRT-53SXC-DMS
CRT-53SXC-DR
CRT-53SXC-DRM
CRT-53SXC-DRMS
CRT-53SXC-DRS
CRT-53SXC-DS
CRT-53SXC-M
CRT-53SXC-MS
CRT-53SXC-R
CCRT-53SXE-M
CCRT-53SXE-MS
CCRT-53SXE-R
CCRT-53SXE-RM
CCRT-53SXE-RMS
CCRT-53SXE-RS
CCRT-53SXE-S
CCRT-53SXE-T
CCRT-53SXE-TM
CCRT-53SXE-TMS
CRT-53SXC-RM
CRT-53SXC-RMS
CRT-53SXC-RS
CRT-53SXC-S
CRT-53SXC-T
CRT-53SX0-T
CRT-53SXC-TM
CRT-53SXC-TMS
CRT-53SXC-TS
CRT-53SXD
CRT-53SX0-TM
CRT-53SX0-TMS
CRT-53SX0-TS
CRT-53SXD-M
*
X = 1 (28Vdc), 2 (15Vdc), 3 (12Vdc) and 4 (24Vdc)
CCRT-53S/CRT-53S Page 8
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2013 TELEDYNE COAX SWITCHES
CCRT-53S\CRT-53S\082013\Q3
相关型号: