DLR30-2125-5050K-B [TELEDYNE]

industrial power relay;
DLR30-2125-5050K-B
型号: DLR30-2125-5050K-B
厂家: TELEDYNE TECHNOLOGIES INCORPORATED    TELEDYNE TECHNOLOGIES INCORPORATED
描述:

industrial power relay

文件: 总7页 (文件大小:453K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
DLR  
industrial power relay  
• High current switching - 6,600VA max.  
• Good inrush current resistance  
• Wide range AC coils  
• DIN Rail mounting options  
• Screw, plug-in or PCB terminals  
• Applications include heaters, HVAC and  
motor controls  
• RoHS Compliant  
Contacts  
Contact number & arrangement  
SPST-NO (1 Form A); DPST-NO (2 Form A)  
AgCdO, AgSnO2 (Special Order only)  
Contact material  
Max. switching voltage  
Min. breaking capacity  
Rated load (resistive - cos φ=1)  
AC/DC 250VAC, 30VDC  
0.5W (AgCdO), 1W (AgSnO2)  
W
AC1 SPST-NO, DPST-NO PCB : 20A/220VAC  
SPST-NO: 30A/220VAC / DPST-NO: 25A/220VAC  
4,400VA (PCB types); 5,500VA (DPST-NO); 6,600VA (SPST-NO)  
≤ 50mΩ, max. at 1A/24VDC  
Max. switching power  
Initial resistance  
Max. operating frequency at rated load  
AC1 1,800 cycles per hour  
Coil  
Rated voltage  
AC 6...200/240V  
DC 6...100V  
Must release voltage  
Operating range of supply voltage  
Insulation  
≥0.15Un  
See coil tables 1 & 2  
Insulation resistance  
Impulse withstand voltage  
Dielectric strength  
≥1000MΩ at 500VDC, 50%RH  
Between coil and contact: 10,000V  
coil to contact 4,000Vrms, 1min (50/60Hz)  
contacts of the same pole 2,000Vrms, 1min (50/60Hz)  
contacts of different poles (DPST-NO) 2,000Vrms, 1min (50/60Hz)  
General Data  
Operating time (typical)  
Release time (typical)  
Electrical Life  
mS ≤ 30  
mS ≤ 30  
ops 1 x 105 at 1,800 ops/hour at rated load (Fig 1.)  
ops 5 x 106 at 1,800 ops/hour  
Mechanical life  
Dimensions  
L x W x H various - see drawings (Fig 2.)  
approx. 90g (3.17oz) quick connect (fast-on) type  
approx. 100g (3.52oz) PCB terminal type  
approx. 120g (4.23oz) Screw terminal type  
-40 to 85°C  
Weight  
Ambient temperature  
Shock resistance  
approx. 100G mechanical durabilty, 10G malfunction durability  
DA 1.5mm 10-55Hz  
Vibration resistance  
Page 1 of 7  
Ref: DLR 091411JHM  
www.durakoolrelays.com  
Sales Department Tel: (888) 847-6552  
Specifications are subject to change without notice. E&OE.  
DLR  
industrial power relay  
DC Coil Data (at 23°C)  
Table 1  
Power  
Consumption  
approx. (mW)  
Must Operate  
Voltage max.  
(V DC)  
Must Release  
Voltage min.  
(V DC)  
Max. Allowable  
Voltage  
Nominal Voltage  
Coil Voltage Code  
Coil Resistance  
(Ω) ±10%  
(V DC)  
(V DC)  
1006  
1012  
1024  
1048  
1100  
6
12  
18.9  
75  
4.5  
9
0.9  
1.8  
6.6  
13.2  
26.4  
52.8  
110.0  
1.9W  
24  
303  
18  
36  
75  
3.6  
0
1
48  
1220  
5260  
7.2  
100  
15.0  
AC Coil Data (at 23°C)  
Table 2  
Power  
Consumption  
approx. (mW)  
Must Operate  
Voltage max.  
(V AC)  
Must Release  
Voltage min.  
(V AC)  
Max. Allowable  
Voltage  
Nominal Voltage  
(V AC)  
Rated Coil Current  
(mA) +15/-20%  
Coil Voltage Code  
(V AC)  
5012  
5024  
5050  
5120  
5230  
12  
24  
142  
71  
9
0.9  
1.8  
3.6  
18  
13.2  
26.4  
55  
1.7 to 2.5VA  
(60Hz)  
18  
50  
34  
37.5  
75  
0
1
100 to 120  
200 to 240  
17 to 20.4  
8.5 to 10.2  
132  
264  
150  
36  
Ordering codes  
Contact  
Material  
Contact  
arrange-  
ment  
Cover pro-  
tection and  
mounting  
Coil code  
Options  
Type  
D
L
R
-
-
-
-
Contact material  
see Tables 1, & 2  
10  
30  
-
-
AgCdO  
AgSnO2 (special order - contact factory)  
Contact arrangement  
21  
22  
-
-
SPST-NO (1 N/O)  
DPST-NO (2 N/O)  
Cover protection category  
2
4
9
-
-
-
in cover, IP40  
cover with flange mount, IP40  
cover with flange and DIN Rail Mount, IP40  
Connection mode  
5
6
8
-
-
-
for PCB  
6.35mm quick connect blade terminals  
screw terminals  
Options  
NIL  
K
-
No option  
-
Test button  
Coil insulation type  
NIL  
B
-
-
Class F (standard)  
Class B (special order - contact factory)  
Page 2 of 7  
Ref: DLR 091411JHM  
www.durakoolrelays.com  
Sales Department Tel: (888) 847-6552  
Specifications are subject to change without notice. E&OE.  
DLR  
industrial power relay  
Reference Curves  
Fig. 1  
DLR SPST-NO (except PCB)  
Maximum Switching Power  
Life Expectancy  
100  
AC resistive load  
50  
40  
30  
20  
AC inductive load  
(cos =0.4)  
220VAC resistive load  
10  
5
220VAC inductive load  
(cos =0.4)  
1
10  
30 50 70 100  
300 500 1,000  
Switching voltage (V)  
Switching current (A)  
DLR DPST-NO (except PCB)  
Maximum Switching Power  
Life Expectancy  
100  
AC inductive load  
AC resistance load  
(cos =0.4)  
50  
40  
30  
20  
220VAC resistive load  
10  
5
220VAC inductive load  
(cos =0.4)  
1
10  
30 50 70 100  
300 500 1,000  
Switching voltage (V)  
Switching current (A)  
DLR PCB SPST-NO, DPST-NO  
Maximum Switching Power  
Life Expectancy  
100  
AC inductive load  
AC resistance load  
(cos =0.4)  
50  
40  
30  
20  
220VAC resistive load  
10  
5
220VAC inductive load  
(cos =0.4)  
1
10  
30 50 70 100  
300 500 1,000  
Switching voltage (V)  
Switching current (A)  
Page 3 of 7  
Ref: DLR 091411JHM  
www.durakoolrelays.com  
Sales Department Tel: (888) 847-6552  
Specifications are subject to change without notice. E&OE.  
DLR  
industrial power relay  
Overall Dimensions and Wiring Diagrams  
Fig. 2  
DLR10-2126 / DLR10-2126-K  
(shown with DLR99 mounting bracket)  
52.5 max.  
50.5 max.  
33.5 max.  
0.8  
Mounting Holes  
(DLR99 Bracket)  
x 4.5-dia. holes or  
6.35  
11  
Two  
M4 tapped holes  
(Top View)  
53 max.  
0
1
4
6
40 +1  
-
DLR10-2226 / DLR10-2226-K  
(shown with DLR99 mounting bracket)  
52.5 max.  
50.5 max.  
33.5 max.  
0.8  
6.35  
11  
(Top View)  
53 max.  
0
1
2
4
6
8
DLR10-2128 / DLR10-2128-K  
(shown with DLR99 mounting bracket)  
Mounting Holes  
(DLR99 Bracket)  
52.5 max.  
50.5 max.  
34.5max.  
(Top View)  
Two  
x M3.5 screws  
for coil  
Two  
x 4.5-dia. holes or  
M4 tapped holes  
0
1
55max.  
4
6
40 +1  
-
DLR10-2228 / DLR10-2228-K  
(shown with DLR99 mounting bracket)  
52.5 max.  
50.5 max.  
34.5max.  
Two  
x M3.5 screws  
for coil  
(Top View)  
0
1
55max.  
2
4
6
8
All dimensions in mm  
Specifications are subject to change without notice. E&OE.  
Page 4 of 7  
Ref: DLR 091411JHM  
www.durakoolrelays.com  
Sales Department Tel: (888) 847-6552  
Specifications are subject to change without notice. E&OE.  
DLR  
industrial power relay  
Overall Dimensions and Wiring Diagrams  
Fig. 2 (cont.)  
DLR10-2146 / DLR10-2146-K  
68.5 max.  
33.5 max.  
0.8  
60  
50.5 max.  
6.35  
(Top View)  
Two x 4.5-dia. holes or  
M4 tapped holes  
11  
0
1
47 max.  
4
6
60+0.2  
-
3
0.8  
DLR10-2246 / DLR10-2246-K  
68.5 max.  
33.5 max.  
0.8  
60  
50.5 max.  
(Top View)  
6.35  
Two x 4.5-dia. holes or  
M4 tapped holes  
11  
0
1
47 max.  
2
4
6
8
60+0.2  
-
3
0.8  
DLR10-2148 / DLR10-2148-K  
Mounting Holes  
68.5 max.  
60 max.  
34.5max.  
Two  
for contact  
x M4 screws  
(Top View)  
50.5 max.  
Two  
for coil  
x
M3.5 screws  
Two x 4.5-dia. holes or  
M4 tapped holes  
0
1
49max.  
4
6
60+0.2  
-
4.5  
DLR10-2248 / DLR10-2248-K  
Mounting Holes  
68.5 max.  
34.5max.  
Two  
for contact  
x
M4 screws  
(Top View)  
60 max.  
50.5 max.  
Two  
for coil  
x M3.5 screws  
Two x 4.5-dia. holes or  
M4 tapped holes  
0
1
49max.  
2
4
6
8
60+0.2  
-
3
4.5  
All dimensions in mm  
Page 5 of 7  
Ref: DLR 091411JHM  
www.durakoolrelays.com  
Sales Department Tel: (888) 847-6552  
Specifications are subject to change without notice. E&OE.  
DLR  
industrial power relay  
Overall Dimensions and Wiring Diagrams  
Fig. 2 (cont.)  
DLR10-2125  
(for PCB mounting)  
Mounting Holes  
(Top View)  
(Top View)  
DLR10-2225  
(for PCB mounting)  
Mounting Holes  
(Top View)  
(Top View)  
DLR10-2196  
(for DIN rail mounting)  
(Top View)  
0
1
4
6
DLR10-2296  
(for DIN rail mounting)  
(Top View)  
0
1
24  
2
68  
4
6
8
All dimensions in mm  
Specifications are subject to change without notice. E&OE.  
Page 6 of 7  
Ref: DLR 091411JHM  
www.durakoolrelays.com  
Sales Department Tel: (888) 847-6552  
Specifications are subject to change without notice. E&OE.  
DLR  
industrial power relay  
Overall Dimensions and Wiring Diagrams  
Fig. 2 (cont.)  
DLR10-2198 / DLR10-2198-K  
(for DIN rail mounting)  
(Top View)  
0
1
4
6
DLR10-2298 / DLR10-2298-K  
(for DIN rail mounting)  
(Top View)  
0
1
24  
2
68  
4
6
8
All dimensions in mm  
Accessories / Overall Dimensions  
Fig. 3  
40  
46  
DLR99 Mounting Bracket  
Two x 4.5-dia. holes  
26 24 17.8  
10  
3
24  
19.7  
7
5
30  
50  
5
4.4  
Two  
x
M3.5 screws  
8
DLR7LF-06 DIN Rail Socket  
for coil  
51.5 max.  
Four x M4 screws  
for contact  
25  
46 max.  
9.2  
5
40 0.1  
55.5 max.  
DLR7LF-C Finger protection cover  
34.5 max.  
1
50.5 max.  
6 max.  
All dimensions in mm  
Page 7 of 7  
Ref: DLR 091411JHM  
www.durakoolrelays.com  
Sales Department Tel: (888) 847-6552  
Specifications are subject to change without notice. E&OE.  

相关型号:

DLR30-2125-5050K-NIL

industrial power relay
TELEDYNE

DLR30-2125-5050NIL-B

industrial power relay
TELEDYNE

DLR30-2125-5050NIL-NIL

industrial power relay
TELEDYNE

DLR30-2125-5120K-B

industrial power relay
TELEDYNE

DLR30-2125-5120K-NIL

industrial power relay
TELEDYNE

DLR30-2125-5120NIL-B

industrial power relay
TELEDYNE

DLR30-2125-5120NIL-NIL

industrial power relay
TELEDYNE

DLR30-2125-5230K-B

industrial power relay
TELEDYNE

DLR30-2125-5230K-NIL

industrial power relay
TELEDYNE

DLR30-2125-5230NIL-B

industrial power relay
TELEDYNE

DLR30-2125-5230NIL-NIL

industrial power relay
TELEDYNE

DLR30-2126-1006K-B

industrial power relay
TELEDYNE