ER134ZM4-26A/SQ [TELEDYNE]
All welded construction;型号: | ER134ZM4-26A/SQ |
厂家: | TELEDYNE TECHNOLOGIES INCORPORATED |
描述: | All welded construction |
文件: | 总6页 (文件大小:142K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
SERIES
CENTIGRID®
ESTABLISHED RELIABILITY
RELAYS
134
SENSITIVE DPDT
SERIES
DESIGNATION
RELAY TYPE
134
DPDT basic relay
134D
DPDT relay with internal diode for coil transient suppression
DPDT relay with internal diodes for coil transient suppression and polarity
reversal protection
134DD
INTERNAL CONSTRUCTION
DESCRIPTION
The 134 sensitive Centigrid® relay retains the same features as the 114
standard Centigrid® relay with only a minimal increase in profile height (.375
in.). Its .100-inch grid spaced terminals, which preclude the need for spreader
pads, and its low profile make the 134 relay ideal for applications where high
packaging density is important.
UNI-FRAME
UPPER
STATIONARY
CONTACT
ARMATURE
The following unique construction features and manufacturing techniques
provide excellent resistance to environmental extremes and overall high
reliability:
• All welded construction.
• Unique uni-frame design providing high magnetic efficiency and mechanical
rigidity.
• High force/mass ratios for resistance to shock and vibration.
• Advanced cleaning techniques provide maximum assurance of internal
cleanliness.
LOWER
STATIONARY
CONTACT
MOVING
CONTACT
• Precious metal alloy contact material with gold plating assures excellent
high current and dry circuit switching capabilities.
The Series 134D and 134DD have internal discrete silicon diodes for coil
suppression and polarity reversal protection.
ENVIRONMENTAL AND
PHYSICAL SPECIFICATIONS
The sensitive 134 Centigrid® relay has a high resistance coil, thus requiring
extremely low operating power (200 mw typical). The advantages of reduced
heat dissipation and power supply demands are a plus.
Temperature
–65°C to +125°C
30 g’s to 3000 Hz
(Ambient)
Vibration
By virtue of its inherently low intercontact capacitance and contact circuit
losses, the 134 relay has proven to be an excellent ultraminiature RF switch
for frequency ranges well into the UHF spectrum. A typical RF application for
the Centigrid® relay is in handheld radio transceivers, wherein the combined
features of good RF performance, small size, low coil power dissipation and
high reliability make it a preferred method of Transmit-Receive switching (see
Figure 1).
(General Note 1)
Shock
75 g’s,
6 msec, half-sine
(General Note 1)
Acceleration
Enclosure
Weight
50 g’s
Hermetically sealed
0.15 oz. (4.3g) max.
134 Page 1
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
www.teledynerelays.com
©2004 TELEDYNE RELAYS
134/0704/Q1
SERIES 134
GENERAL ELECTRICAL SPECIFICATIONS (–65°C to +125°C unless otherwise noted) (Notes 2 & 3)
Contact Arrangement
Rated Duty
2 Form C (DPDT)
Continuous
Contact Resistance
0.1 ohm max. before life; 0.2 ohm max. after life at 1A/28Vdc (measured 1/8" from header)
Resistive:
Inductive:
Lamp:
1 Amp/28Vdc
200 mA/28Vdc (320 mH)
100 mA/28Vdc
Contact Load Ratings (DC)
(See Fig. 2 for other DC
resistive voltage/current ratings)
Low Level:
10 to 50 μA/10 to 50mV
Resistive:
250 mA/115Vac, 60 and 400 Hz (Case not grounded)
100 mA/115Vac, 60 and 400 Hz (Case grounded)
Contact Load Ratings (AC)
Contact Life Ratings
10,000,000 cycles (typical) at low level
1,000,000 cycles (typical) at 0.5A/28Vdc resistive
100,000 cycles min. at all other loads specified above
Contact Overload Rating
Contact Carry Rating
Coil Operating Power
Operate Time
2A/28Vdc Resistive (100 cycles min.)
Contact factory
200 milliwatts typical at nominal rated voltage @ 25°C
4.0 msec max. at nominal rated coil voltage
134 Series: 2.0 msec max. 134D, 134DD Series: 7.5 msec max.
1.5 msec max.
Release Time
Contact Bounce
Intercontact Capacitance
Insulation Resistance
Dielectric Strength
Negative Coil Transient (Vdc)
Diode P.I.V. (Vdc)
0.4 pf typical
10,000 megohms min. between mutually isolated terminals
Atmospheric pressure: 500 Vrms/60Hz
134D, 134DD
70,000 ft.: 125 Vrms/60Hz
1.0 max
100 min.
134D, 134DD
DETAILED ELECTRICAL SPECIFICATIONS (–65°C to +125°C unless otherwise noted) (Note 3)
134-5
134D-5
134DD-5
134-6
134D-6
134DD-6
134-9
134D-9
134-12
134D-12
134-18
134D-18
134-26
134D-26
BASE PART
NUMBERS
(See Note 8 for full P/N example)
134DD-9 134DD-12 134DD-18 134DD-26
Nom.
Max.
5.0
7.5
6.0
10.0
200
125
36.3
48.9
4.5
9.0
15.0
400
400
18.1
23.6
6.8
12.0
20.0
800
800
12.5
16.0
9.0
18.0
30.0
1600
1600
9.6
26.5
40.0
3200
3200
7.2
Coil Voltage (Vdc)
Coil Resistance
134, 134D
100
64
(Ohms 1ꢀ0 ꢁ25°C)
134DD (Note 4)
Min.
56.8
78.1
3.5
Coil Current (mAdc ꢁ25°C)
(134DD Series)
Max.
12.2
13.5
14.5
0.59
10.0
1.1
9.0
134, 134D
134DD
18.0
19.0
0.89
13.0
1.3
Pick-up Voltage (Vdc, Max.)
3.7
4.8
8.0
11.0
0.41
6.5
Min.
Max.
Min.
Max.
0.12
2.5
0.18
3.2
0.35
4.9
134, 134D
134DD
Drop-out Voltage (Vdc)
0.7
0.8
0.9
1.0
2.6
3.0
4.5
5.8
9.0
13.0
PERFORMANCE CURVES
(NOTE 2)
TYPICAL RF PERFORMANCE
TYPICAL DC CONTACT RATING (RESISTIVE)
0
.1
300
250
200
150
100
50
.2
.3
.4
10
20
30
40
50
60
70
1.92
1.22
1.07
1.02
1.01
1.00
1.00
.01
0.5
.1
.5
1.0
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
LOAD CURRENT (AMPS DC)
FREQUENCY (GHz)
FIGURE 2
FIGURE 1
©2003 TELEDYNE RELAYS
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
www.teledynerelays.com
134 Page 2
134/1203/Q1
SERIES 134
SCHEMATIC DIAGRAMS
OUTLINE DIMENSIONS
CASE DETAIL
.375 (9.53)
SQ. MAX.
TERMINAL LOCATIONS
(Viewed from Terminals; Numbers for Reference Only)
.031 .003
(.79 .08)
.335 (8.51)
SQ. MAX.
.035 .010
(.89 .25)
134
8
4
.375 (9.53) MAX.
7
1
.100 .010
(2.54 .25)
TYP 8 PLACES
6
5
2
3
WIRE LEAD .750 (19.05) MIN.
PIN: .187 (1.75) .010 (.25)
(See Note 5)
DIMENSIONS ARE SHOWN IN INCHES (MILLIMETERS)
+.002 (.05)
–.001 (.03)
.017 (.43)
DIA.
134D
GENERAL NOTES
1. Relay contacts will exhibit no chatter in excess of 10 μsec or transfer in excess of 1 μsec.
2. “Typical” characteristics are based on available data and are best estimates. No on-going
verification tests are performed.
3. Unless otherwise specified, parameters are initial values.
4. For reference only. Coil resistance not directly measurable at relay terminals due to
internal series diode in 134DD only.
134DD
5. Unless otherwise specified, relays will be supplied with either gold-plated or solder-
coated leads.
6. The slash and characters appearing after the slash are not marked on the relay.
7. Screened HI-REL versions available. Contact factory.
8.
SCHEMATICS ARE VIEWED
FROM TERMINALS
2
®
Teledyne Part Numbering System for T R Established Reliability Relay
ER 134
Z
M4 - 26 A / S Q
Q= Solder-Coated Leads
G= Gold-Plated Leads
(Notes 5 and 6)
Estab
lished Reli
ability
Designator
Relay Series
S= .187" leads
(Note 6)
Ground Pin Option
(See Appendix)
Screening and Reliability
Level
Pad Option
(See Appendix)
Coil Voltage
Teledyne Part Numbering System for Military Qualified (JAN) Relays
134 M4 - 26
J
Z
P
L
Militar
y (JAN)
Screening and Reliability
Level
Designator
Relay Series
Ground Pin Option
(See Appendix)
Terminal Variant
P = 0.187"
Coil Voltage
Pad Option
(See Appendix)
134 Page 3
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
www.teledynerelays.com
©2004 TELEDYNE RELAYS
134/0704/Q1
Appendix A: Spacer Pads
Pad designation and
Dim. H
Max.
Height
For use with the following:
bottom view dimensions
ER411T
ER412, ER412D, ER412DD
712, 712D, 712TN,
RF300, RF310, RF320
.295 (7.49)
Ø.150
[3.81]
(REF)
.300 (7.62)
Dim
MAX
H
ER420, ER422D, ER420DD, 421,
ER421D, ER421DD, ER422, ER422D, .305 (7.75)
ER422DD, 722, 722D, RF341
ER431T, ER432T,
ER432, ER432D, ER432DD
.400 (10.16)
732, 732D, 732TN, RF303, RF313,
RF323
.410 (10.41)
RF312
.350 (8.89)
.295 (7.49)
“M4” Pad for TO-5
“M4” Pad for TO-5
ER411, ER411D, ER411DD
Dim
MAX
H
ER431, ER431D, ER431DD
RF311
.400 (10.16)
.300 (7.62)
RF331
.410 (10.41)
.305 (7.75)
172, 172D
ER114, ER114D, ER114DD,
J114, J114D, J114DD
Dim
MAX
H
.300 (7.62)
ER134, ER134D, ER134DD,
J134, J134D, J134DD
.400 (10.16)
RF100
RF103
.315 (8.00)
“M4” Pad for Centigrid®
.420 (10.67)
.156
[3.96]
(REF)
122C, A152
.320 (8.13)
.300 (7.62)
Dim
MAX
H
ER116C, J116C
.256
[6.5]
ER136C, J136C
RF180
.400 (10.16)
.325 (8.25)
.305 (7.75)
(REF)
A150
“M9” Pad for Centigrid®
Notes:
1. Spacer pad material: Polyester ꢀlm.
2. To specify an “M4” or “M9” spacer pad, refer to the mounting variants portion of the part numbering
example in the applicable datasheet.
3. Dimensions are in inches (mm).
4. Unless otherwise speciꢀed, tolerance is .010 (.25).
5. Add 10 mꢁ to the contact resistance show in the datasheet.
6. Add 0.01 oz. (0.25 g) to the weight of the relay assembly shown in the datasheet.
© 2008 Teledyne Relays
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
Appendix A: Spreader Pads
Pad designation and
bottom view dimensions
Dim. H
Max.
Height
For use with the following:
ER411T, J411T, ER412, ER412D
ER412DD, J412, J412D, J412DD
ER412T, J412T
.370 [9.4]
MAX SQ
.388 (9.86)
.393 (9.99)
.493 (12.52)
.503 (12.78)
.100
[2.54]
Dim
MAX
H
712, 712D, 712TN
.150
.014
[0.36]
(REF)
ER431T, J431T, ER432, ER432D
ER432DD, J432, J432D, J432DD
ER432T, J432T
[3.81]
.300
[7.62]
.100
[2.54]
732, 732D, 732TN
.370
[9.4]
MIN
ER420, J420, ER420D, J420D
ER420DD, J420DD, ER421, J421
ER421D, J421D, ER421DD
.200
[5.08]
.398 (10.11)
J422D, ER422DD, J422DD, 722
“M” Pad 5/ 6/
.390 [9.91]
SQ
ER411T
ER412, ER412D, ER412DD
J412, J412D, J412DD
.100
[2.54]
.441 (11.20)
.100
[2.54]
.150
[3.81]
Dim
MAX
H
712, 712D
ER421, ER421D, ER421DD
722, 732D
.451 (11.46)
.451 (11.46)
.300
[7.62]
ER431T
.130
[3.3]
.150
[3.81]
.546 (13.87)
.556 (14.12)
ER432, ER432D, ER432DD
.300
[7.62]
732, 732D
“M2” Pad 7/ 8/
ER411, ER411D, ER411DD
ER411TX
ER412X, ER412DX, ER412DDX
ER412TX
.388 (9.86)
.393 (9.99)
.398 (10.11)
.370 [9.4]
MAX SQ
.100
[2.54]
712X, 712DX, 712TNX
Dim
MAX
H
ER420X, ER420DX, ER420DDX
ER421X, ER421DX, ER421DDX
ER422X, ER422DX
ER422DDX, 722X, 722DDX
ER431, ER431D, ER431DD
ER431TX
ER432X, ER432DX, ER432DDX
ER432TX
732X, 732DX, 732TNX
.150
[3.81]
.014
[0.36]
(REF)
.300
[7.62]
.100
[2.54]
.370
[9.4]
MIN
.200
[5.08]
.493 (12.52)
.503 (12.78)
“M3” Pad 5/ 6/ 9/
Notes:
1. Spreader pad material: Diallyl Phthalate.
2. To specify an “M”, “M2” or “M3” spreader pad, refer to the mounting variants portion of the part number example
in the applicable datasheet.
3. Dimensions are in inches (mm).
4. Unless otherwise speciꢀed, tolerance is .010” (0.25).
5/. Add 25 mꢁ to the contact resistance shown in the datasheet.
6/. Add .01 oz. (0.25 g) to the weight of the relay assembly shown in the datasheet.
7/. Add 50 mꢁ to the contact resistance shown in the datasheet.
8/. Add 0.025 oz (0.71 g) to the weight of the relay assembly shown in the datasheet.
9/. M3 pad to be used only when the relay has a center pin (e.g. ER411M3-12A, 722XM3-26.)
(800) 284-7007 • www.teledynerelays.com
ꢂ
+44 (0) 1236 453124 • www.teledyne-europe.com
© 2008 Teledyne Relays
Appendix A: Ground Pin Positions
"Z" POSITION
"X" POSITION
"Z" POSITION
Ø.200
[Ø5.08]
Ø.200
[Ø5.08]
"Y" POSITION
45° 3°
"Y" POSITION
36° 3°
TO-5 Relays:
TO-5 Relays:
ER411, ER431, RF311, RF331
ER411T, ER412, ER412T, ER420, ER421, ER422,
ER431T, ER432, ER432T, 712, 712TN, 400H, 400K,
400V, RF300, RF303, RF341, RF312, RF310, RF313,
RF320, RF323
"Y" POSITION
.100
[2.54]
"Y" POSITION
"Z" POSITION
"W" POSITION
"Z" POSITION
.100
[2.54]
.100
[2.54]
.050
[1.27]
.100
[2.54]
"X" POSITION
"U" POSITION
.100
[2.54]
.100
[2.54]
(ER116C and ER136C only)
Centigrid® Relays:
RF180, ER116C, 122C, ER136C
Centigrid® Relays:
RF100, RF103, ER114, ER134, 172
NOTES
1. Terminal views shown
2. Dimensions are in inches (mm)
Indicates ground pin position
3. Tolerances: .010 ( .25) unless otherwise speciꢀed
4. Ground pin positions are within .015 (0.38) dia. of true position
5. Ground pin head dia., 0.035 (0.89) ref: height 0.010 (0.25) ref.
6. Lead dia. 0.017 (0.43) nom.
Indicates glass insulated lead position
Indicates ground pin or lead position
depending on relay type
© 2008 Teledyne Relays
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
相关型号:
©2020 ICPDF网 联系我们和版权申明