ER134ZM4-26A/SQ [TELEDYNE]

All welded construction;
ER134ZM4-26A/SQ
型号: ER134ZM4-26A/SQ
厂家: TELEDYNE TECHNOLOGIES INCORPORATED    TELEDYNE TECHNOLOGIES INCORPORATED
描述:

All welded construction

文件: 总6页 (文件大小:142K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
SERIES  
CENTIGRID®  
ESTABLISHED RELIABILITY  
RELAYS  
134  
SENSITIVE DPDT  
SERIES  
DESIGNATION  
RELAY TYPE  
134  
DPDT basic relay  
134D  
DPDT relay with internal diode for coil transient suppression  
DPDT relay with internal diodes for coil transient suppression and polarity  
reversal protection  
134DD  
INTERNAL CONSTRUCTION  
DESCRIPTION  
The 134 sensitive Centigrid® relay retains the same features as the 114  
standard Centigrid® relay with only a minimal increase in profile height (.375  
in.). Its .100-inch grid spaced terminals, which preclude the need for spreader  
pads, and its low profile make the 134 relay ideal for applications where high  
packaging density is important.  
UNI-FRAME  
UPPER  
STATIONARY  
CONTACT  
ARMATURE  
The following unique construction features and manufacturing techniques  
provide excellent resistance to environmental extremes and overall high  
reliability:  
• All welded construction.  
• Unique uni-frame design providing high magnetic efficiency and mechanical  
rigidity.  
• High force/mass ratios for resistance to shock and vibration.  
• Advanced cleaning techniques provide maximum assurance of internal  
cleanliness.  
LOWER  
STATIONARY  
CONTACT  
MOVING  
CONTACT  
• Precious metal alloy contact material with gold plating assures excellent  
high current and dry circuit switching capabilities.  
The Series 134D and 134DD have internal discrete silicon diodes for coil  
suppression and polarity reversal protection.  
ENVIRONMENTAL AND  
PHYSICAL SPECIFICATIONS  
The sensitive 134 Centigrid® relay has a high resistance coil, thus requiring  
extremely low operating power (200 mw typical). The advantages of reduced  
heat dissipation and power supply demands are a plus.  
Temperature  
–65°C to +125°C  
30 g’s to 3000 Hz  
(Ambient)  
Vibration  
By virtue of its inherently low intercontact capacitance and contact circuit  
losses, the 134 relay has proven to be an excellent ultraminiature RF switch  
for frequency ranges well into the UHF spectrum. A typical RF application for  
the Centigrid® relay is in handheld radio transceivers, wherein the combined  
features of good RF performance, small size, low coil power dissipation and  
high reliability make it a preferred method of Transmit-Receive switching (see  
Figure 1).  
(General Note 1)  
Shock  
75 g’s,  
6 msec, half-sine  
(General Note 1)  
Acceleration  
Enclosure  
Weight  
50 g’s  
Hermetically sealed  
0.15 oz. (4.3g) max.  
134 Page 1  
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE  
www.teledynerelays.com  
©2004 TELEDYNE RELAYS  
134/0704/Q1  
SERIES 134  
GENERAL ELECTRICAL SPECIFICATIONS (–65°C to +125°C unless otherwise noted) (Notes 2 & 3)  
Contact Arrangement  
Rated Duty  
2 Form C (DPDT)  
Continuous  
Contact Resistance  
0.1 ohm max. before life; 0.2 ohm max. after life at 1A/28Vdc (measured 1/8" from header)  
Resistive:  
Inductive:  
Lamp:  
1 Amp/28Vdc  
200 mA/28Vdc (320 mH)  
100 mA/28Vdc  
Contact Load Ratings (DC)  
(See Fig. 2 for other DC  
resistive voltage/current ratings)  
Low Level:  
10 to 50 μA/10 to 50mV  
Resistive:  
250 mA/115Vac, 60 and 400 Hz (Case not grounded)  
100 mA/115Vac, 60 and 400 Hz (Case grounded)  
Contact Load Ratings (AC)  
Contact Life Ratings  
10,000,000 cycles (typical) at low level  
1,000,000 cycles (typical) at 0.5A/28Vdc resistive  
100,000 cycles min. at all other loads specified above  
Contact Overload Rating  
Contact Carry Rating  
Coil Operating Power  
Operate Time  
2A/28Vdc Resistive (100 cycles min.)  
Contact factory  
200 milliwatts typical at nominal rated voltage @ 25°C  
4.0 msec max. at nominal rated coil voltage  
134 Series: 2.0 msec max. 134D, 134DD Series: 7.5 msec max.  
1.5 msec max.  
Release Time  
Contact Bounce  
Intercontact Capacitance  
Insulation Resistance  
Dielectric Strength  
Negative Coil Transient (Vdc)  
Diode P.I.V. (Vdc)  
0.4 pf typical  
10,000 megohms min. between mutually isolated terminals  
Atmospheric pressure: 500 Vrms/60Hz  
134D, 134DD  
70,000 ft.: 125 Vrms/60Hz  
1.0 max  
100 min.  
134D, 134DD  
DETAILED ELECTRICAL SPECIFICATIONS (–65°C to +125°C unless otherwise noted) (Note 3)  
134-5  
134D-5  
134DD-5  
134-6  
134D-6  
134DD-6  
134-9  
134D-9  
134-12  
134D-12  
134-18  
134D-18  
134-26  
134D-26  
BASE PART  
NUMBERS  
(See Note 8 for full P/N example)  
134DD-9 134DD-12 134DD-18 134DD-26  
Nom.  
Max.  
5.0  
7.5  
6.0  
10.0  
200  
125  
36.3  
48.9  
4.5  
9.0  
15.0  
400  
400  
18.1  
23.6  
6.8  
12.0  
20.0  
800  
800  
12.5  
16.0  
9.0  
18.0  
30.0  
1600  
1600  
9.6  
26.5  
40.0  
3200  
3200  
7.2  
Coil Voltage (Vdc)  
Coil Resistance  
134, 134D  
100  
64  
(Ohms 1ꢀ0 ꢁ25°C)  
134DD (Note 4)  
Min.  
56.8  
78.1  
3.5  
Coil Current (mAdc ꢁ25°C)  
(134DD Series)  
Max.  
12.2  
13.5  
14.5  
0.59  
10.0  
1.1  
9.0  
134, 134D  
134DD  
18.0  
19.0  
0.89  
13.0  
1.3  
Pick-up Voltage (Vdc, Max.)  
3.7  
4.8  
8.0  
11.0  
0.41  
6.5  
Min.  
Max.  
Min.  
Max.  
0.12  
2.5  
0.18  
3.2  
0.35  
4.9  
134, 134D  
134DD  
Drop-out Voltage (Vdc)  
0.7  
0.8  
0.9  
1.0  
2.6  
3.0  
4.5  
5.8  
9.0  
13.0  
PERFORMANCE CURVES  
(NOTE 2)  
TYPICAL RF PERFORMANCE  
TYPICAL DC CONTACT RATING (RESISTIVE)  
0
.1  
300  
250  
200  
150  
100  
50  
.2  
.3  
.4  
10  
20  
30  
40  
50  
60  
70  
1.92  
1.22  
1.07  
1.02  
1.01  
1.00  
1.00  
.01  
0.5  
.1  
.5  
1.0  
0
0.1  
0.2  
0.3  
0.4  
0.5  
0.6  
0.7  
0.8  
0.9  
1.0  
LOAD CURRENT (AMPS DC)  
FREQUENCY (GHz)  
FIGURE 2  
FIGURE 1  
©2003 TELEDYNE RELAYS  
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE  
www.teledynerelays.com  
134 Page 2  
134/1203/Q1  
SERIES 134  
SCHEMATIC DIAGRAMS  
OUTLINE DIMENSIONS  
CASE DETAIL  
.375 (9.53)  
SQ. MAX.  
TERMINAL LOCATIONS  
(Viewed from Terminals; Numbers for Reference Only)  
.031 .003  
(.79 .08)  
.335 (8.51)  
SQ. MAX.  
.035 .010  
(.89 .25)  
134  
8
4
.375 (9.53) MAX.  
7
1
.100 .010  
(2.54 .25)  
TYP 8 PLACES  
6
5
2
3
WIRE LEAD .750 (19.05) MIN.  
PIN: .187 (1.75) .010 (.25)  
(See Note 5)  
DIMENSIONS ARE SHOWN IN INCHES (MILLIMETERS)  
+.002 (.05)  
–.001 (.03)  
.017 (.43)  
DIA.  
134D  
GENERAL NOTES  
1. Relay contacts will exhibit no chatter in excess of 10 μsec or transfer in excess of 1 μsec.  
2. “Typical” characteristics are based on available data and are best estimates. No on-going  
verification tests are performed.  
3. Unless otherwise specified, parameters are initial values.  
4. For reference only. Coil resistance not directly measurable at relay terminals due to  
internal series diode in 134DD only.  
134DD  
5. Unless otherwise specified, relays will be supplied with either gold-plated or solder-  
coated leads.  
6. The slash and characters appearing after the slash are not marked on the relay.  
7. Screened HI-REL versions available. Contact factory.  
8.  
SCHEMATICS ARE VIEWED  
FROM TERMINALS  
2
®
Teledyne Part Numbering System for T R Established Reliability Relay  
ER 134  
Z
M4 - 26 A / S Q  
Q= Solder-Coated Leads  
G= Gold-Plated Leads  
(Notes 5 and 6)  
Estab  
lished Reli  
ability  
Designator  
Relay Series  
S= .187" leads  
(Note 6)  
Ground Pin Option  
(See Appendix)  
Screening and Reliability  
Level  
Pad Option  
(See Appendix)  
Coil Voltage  
Teledyne Part Numbering System for Military Qualified (JAN) Relays  
134 M4 - 26  
J
Z
P
L
Militar  
y (JAN)  
Screening and Reliability  
Level  
Designator  
Relay Series  
Ground Pin Option  
(See Appendix)  
Terminal Variant  
P = 0.187"  
Coil Voltage  
Pad Option  
(See Appendix)  
134 Page 3  
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE  
www.teledynerelays.com  
©2004 TELEDYNE RELAYS  
134/0704/Q1  
Appendix A: Spacer Pads  
Pad designation and  
Dim. H  
Max.  
Height  
For use with the following:  
bottom view dimensions  
ER411T  
ER412, ER412D, ER412DD  
712, 712D, 712TN,  
RF300, RF310, RF320  
.295 (7.49)  
Ø.150  
[3.81]  
(REF)  
.300 (7.62)  
Dim  
MAX  
H
ER420, ER422D, ER420DD, 421,  
ER421D, ER421DD, ER422, ER422D, .305 (7.75)  
ER422DD, 722, 722D, RF341  
ER431T, ER432T,  
ER432, ER432D, ER432DD  
.400 (10.16)  
732, 732D, 732TN, RF303, RF313,  
RF323  
.410 (10.41)  
RF312  
.350 (8.89)  
.295 (7.49)  
“M4” Pad for TO-5  
“M4” Pad for TO-5  
ER411, ER411D, ER411DD  
Dim  
MAX  
H
ER431, ER431D, ER431DD  
RF311  
.400 (10.16)  
.300 (7.62)  
RF331  
.410 (10.41)  
.305 (7.75)  
172, 172D  
ER114, ER114D, ER114DD,  
J114, J114D, J114DD  
Dim  
MAX  
H
.300 (7.62)  
ER134, ER134D, ER134DD,  
J134, J134D, J134DD  
.400 (10.16)  
RF100  
RF103  
.315 (8.00)  
“M4” Pad for Centigrid®  
.420 (10.67)  
.156  
[3.96]  
(REF)  
122C, A152  
.320 (8.13)  
.300 (7.62)  
Dim  
MAX  
H
ER116C, J116C  
.256  
[6.5]  
ER136C, J136C  
RF180  
.400 (10.16)  
.325 (8.25)  
.305 (7.75)  
(REF)  
A150  
“M9” Pad for Centigrid®  
Notes:  
1. Spacer pad material: Polyester ꢀlm.  
2. To specify an “M4” or “M9” spacer pad, refer to the mounting variants portion of the part numbering  
example in the applicable datasheet.  
3. Dimensions are in inches (mm).  
4. Unless otherwise speciꢀed, tolerance is .010 (.25).  
5. Add 10 mꢁ to the contact resistance show in the datasheet.  
6. Add 0.01 oz. (0.25 g) to the weight of the relay assembly shown in the datasheet.  
© 2008 Teledyne Relays  
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE  
Appendix A: Spreader Pads  
Pad designation and  
bottom view dimensions  
Dim. H  
Max.  
Height  
For use with the following:  
ER411T, J411T, ER412, ER412D  
ER412DD, J412, J412D, J412DD  
ER412T, J412T  
.370 [9.4]  
MAX SQ  
.388 (9.86)  
.393 (9.99)  
.493 (12.52)  
.503 (12.78)  
.100  
[2.54]  
Dim  
MAX  
H
712, 712D, 712TN  
.150  
.014  
[0.36]  
(REF)  
ER431T, J431T, ER432, ER432D  
ER432DD, J432, J432D, J432DD  
ER432T, J432T  
[3.81]  
.300  
[7.62]  
.100  
[2.54]  
732, 732D, 732TN  
.370  
[9.4]  
MIN  
ER420, J420, ER420D, J420D  
ER420DD, J420DD, ER421, J421  
ER421D, J421D, ER421DD  
.200  
[5.08]  
.398 (10.11)  
J422D, ER422DD, J422DD, 722  
“M” Pad 5/ 6/  
.390 [9.91]  
SQ  
ER411T  
ER412, ER412D, ER412DD  
J412, J412D, J412DD  
.100  
[2.54]  
.441 (11.20)  
.100  
[2.54]  
.150  
[3.81]  
Dim  
MAX  
H
712, 712D  
ER421, ER421D, ER421DD  
722, 732D  
.451 (11.46)  
.451 (11.46)  
.300  
[7.62]  
ER431T  
.130  
[3.3]  
.150  
[3.81]  
.546 (13.87)  
.556 (14.12)  
ER432, ER432D, ER432DD  
.300  
[7.62]  
732, 732D  
“M2” Pad 7/ 8/  
ER411, ER411D, ER411DD  
ER411TX  
ER412X, ER412DX, ER412DDX  
ER412TX  
.388 (9.86)  
.393 (9.99)  
.398 (10.11)  
.370 [9.4]  
MAX SQ  
.100  
[2.54]  
712X, 712DX, 712TNX  
Dim  
MAX  
H
ER420X, ER420DX, ER420DDX  
ER421X, ER421DX, ER421DDX  
ER422X, ER422DX  
ER422DDX, 722X, 722DDX  
ER431, ER431D, ER431DD  
ER431TX  
ER432X, ER432DX, ER432DDX  
ER432TX  
732X, 732DX, 732TNX  
.150  
[3.81]  
.014  
[0.36]  
(REF)  
.300  
[7.62]  
.100  
[2.54]  
.370  
[9.4]  
MIN  
.200  
[5.08]  
.493 (12.52)  
.503 (12.78)  
“M3” Pad 5/ 6/ 9/  
Notes:  
1. Spreader pad material: Diallyl Phthalate.  
2. To specify an “M”, “M2” or “M3” spreader pad, refer to the mounting variants portion of the part number example  
in the applicable datasheet.  
3. Dimensions are in inches (mm).  
4. Unless otherwise speciꢀed, tolerance is .010” (0.25).  
5/. Add 25 mꢁ to the contact resistance shown in the datasheet.  
6/. Add .01 oz. (0.25 g) to the weight of the relay assembly shown in the datasheet.  
7/. Add 50 mꢁ to the contact resistance shown in the datasheet.  
8/. Add 0.025 oz (0.71 g) to the weight of the relay assembly shown in the datasheet.  
9/. M3 pad to be used only when the relay has a center pin (e.g. ER411M3-12A, 722XM3-26.)  
(800) 284-7007 • www.teledynerelays.com  
+44 (0) 1236 453124 • www.teledyne-europe.com  
© 2008 Teledyne Relays  
Appendix A: Ground Pin Positions  
"Z" POSITION  
"X" POSITION  
"Z" POSITION  
Ø.200  
[Ø5.08]  
Ø.200  
[Ø5.08]  
"Y" POSITION  
45° 3°  
"Y" POSITION  
36° 3°  
TO-5 Relays:  
TO-5 Relays:  
ER411, ER431, RF311, RF331  
ER411T, ER412, ER412T, ER420, ER421, ER422,  
ER431T, ER432, ER432T, 712, 712TN, 400H, 400K,  
400V, RF300, RF303, RF341, RF312, RF310, RF313,  
RF320, RF323  
"Y" POSITION  
.100  
[2.54]  
"Y" POSITION  
"Z" POSITION  
"W" POSITION  
"Z" POSITION  
.100  
[2.54]  
.100  
[2.54]  
.050  
[1.27]  
.100  
[2.54]  
"X" POSITION  
"U" POSITION  
.100  
[2.54]  
.100  
[2.54]  
(ER116C and ER136C only)  
Centigrid® Relays:  
RF180, ER116C, 122C, ER136C  
Centigrid® Relays:  
RF100, RF103, ER114, ER134, 172  
NOTES  
1. Terminal views shown  
2. Dimensions are in inches (mm)  
Indicates ground pin position  
3. Tolerances: .010 ( .25) unless otherwise speciꢀed  
4. Ground pin positions are within .015 (0.38) dia. of true position  
5. Ground pin head dia., 0.035 (0.89) ref: height 0.010 (0.25) ref.  
6. Lead dia. 0.017 (0.43) nom.  
Indicates glass insulated lead position  
Indicates ground pin or lead position  
depending on relay type  
© 2008 Teledyne Relays  
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE  

相关型号:

ER14.5

Planar ER cores and accessories
FERROXCUBE

ER14.5

TELECOM TRANSFORMERS
AITSEMI

ER14.5-3-7-3C92-S

Planar ER cores and accessories
FERYSTER

ER14.5-3C92-S

Planar ER cores and accessories
FERROXCUBE

ER14.5-3C93-S

Planar ER cores and accessories
FERROXCUBE

ER14.5-3C94-A100-S

Planar ER cores and accessories
FERROXCUBE

ER14.5-3C94-A160-S

Planar ER cores and accessories
FERROXCUBE

ER14.5-3C94-A250-S

Planar ER cores and accessories
FERROXCUBE

ER14.5-3C94-S

Planar ER cores and accessories
FERROXCUBE

ER14.5-3C95-S

Planar ER cores and accessories
FERROXCUBE

ER14.5-3C96-S

Planar ER cores and accessories
FERROXCUBE

ER14.5-3F3-A100-S

Planar ER cores and accessories
FERROXCUBE