LS60D22C [TELEDYNE]
30A to 600 Vac SIP Package DC control; 30A至600 VAC SIP封装DC控制型号: | LS60D22C |
厂家: | TELEDYNE TECHNOLOGIES INCORPORATED |
描述: | 30A to 600 Vac SIP Package DC control |
文件: | 总6页 (文件大小:195K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Series LS
30A to 600 Vac SIP Package
DC control
Part Number
LS24D16C
LS24D21C
LS60D22C
LS24D27C
LS60D27C
LS60D30C
Description
16A, 240 Vac
21A, 240 Vac
22A, 600 Vac
27A, 240 Vac
27A, 600 Vac
30A, 600 Vac
FEATURES/BENEFITS
• Industry standard package
Part Number Explanation
• Designed for external heat-sink attachment
• Over-sized thyristor ratings
LS
24
D
16
C
• Direct-copper bonding technology
DESCRIPTION
These solid-state single inline package (SIP) relays
are designed for mounting on printed circuit boards.
The Series LS relays facilitate heat sinking by
providing an interface surface. The relays are
designed with 16A, 25Aand 50Athyristors. They can
switch loads with high starting currents. The nominal
switched currents depend on the size of the heat sink
and are limited by the cross section of the tracks of
the printed circuit (mainly 25A/30A). The relays use
a direct-bonded copper substrate for thermal
efficiency, thermal stress performance and long-life
expectancy.
NOTES
1) Line Voltage (nominal): 24 = 240 Vac; 60 = 600 Vac
2) Switch Type: D = Zero-cross turn-on
3) Control Range: C = 4-14 Vdc (N = 8-32 Vdc also available)
MECHANICAL SPECIFICATION
.01 (0.3)
Hot surface: 1.48 (37.6)
4
3
2
1
Ø1
0.4
(10.16)
.31
0.2 (5.08)
0.5 (12.7)
1.82 (43.6)
.07 (1.7)
.07 (1.7)
(7.83)
0.3
(7.83)
APPLICATIONS
• Motor control — Pumps, reversing, integration of
relays in terminal boxes
.25 (6.3)
• Lamp control — Infrared drying, traffic lights,
theater lighting
To p view
Hole Ø.06 (1.6)
0.1 (2.54)
+
WEIGHT: 0.53 oz. (15g)
TOLERANCES: 0.01
–
APPROVALS
All models are UL recognized.
UL File Number: E128555.
Figure 1 — LS relays; dimensions in inches (mm)
(See Figure 12 for LS with HS1)
TYPICAL APPLICATION
L
L
1
1
BLOCK DIAGRAM
MOV on
the PCB
Load
3 +
Or
Ic
SSR
Rc
1 ~
2 ~
MOV on
the PCB
Vc
Load
4 –
SSR
N
N
Figure 2 — LS relays
Figure 3 — LS relays
© 2003 TELEDYNE RELAYS
(800) 284-7007 • www.teledynerelays.com
LS 1
LS\032003\Q2
Series LS
INPUT (CONTROL) SPECIFICATION
CONTROL CHARACTERISTIC
30
28
26
24
22
20
18
16
14
12
10
8
Min
4
Max
14
Units
Vdc
Control Range
Input Current Range
Must Turn-off Voltage
Input Resistance (Typical)
6.5
30
mAdc
Vdc
1
440
Ohms
6
OUTPUT (LOAD) SPECIFICATION
4
2
Min
Max
Unit
0
0
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16
Operating Range
LS24
Control Voltage (V)
12
24
280
600
Vrms
Vrms
Figure 4 — LS relays
THERMAL CHARACTERISTICS
LS60
20
15
10
Peak Voltage
LS24D16C
LS60D22C
~
FW150 ( 3°C/W)
~
FW100
600
Vpeak
~
( 4°C/W)
~
Full on state
1200 Vpeak
6°C/W
Load Current Range
LS24D16C
.005
.005
.005
.005
.005
.005
16*
25*
25*
30*
30*
30*
Arms
Arms
Arms
Arms
Arms
Arms
5
0
LS24D21C
Without heat sink
LS60D22C
LS24D27C
0
5
10
15
20
0
10 20 30 40 50 60 70 80 90 100
Load Current (Arms)
Ambient Temperature (°C)
LS60D27C
Figure 5a — LS24D16C relay
LS60D30C
*Limited by the heat sink
35
30
25
20
15
10
5
~
FW150 ( 3°C/W)
Full on state
~
Maximum Surge Current Rating (Non-Repetitive)
(See Figure 6)
FW100
~
~
(
4°C/W)
6°C/W
LS24D16C
LS24D21C
LS60D22C
LS24D27C
LS60D27C
LS60D30C
160
250
300
600
600
Apeak
Apeak
Apeak
Apeak
Apeak
Without heat sink
0
0
5
10
15
20
25
0
10 20 30 40 50 60 70 80 90 100
Load Current (Arms)
Ambient Temperature (°C)
Figure 5b — LS24D21C, LS60D22C relays
1000 Apeak
40
On-State Voltage Drop
All relays
Full on state
~
FW150 ( 3°C/W)
~
FW100
~
30
20
10
0
1.6
±12
1
V
V
~
(
4°C/W)
6°C/W
Zero-Cross Window (Typical)
All relays
Without heat sink
Off-State Leakage Current (60Hz)
All relays
0
10 20 30 40 50 60 70 80 90 100
0
5
10 15 20 25 30 35
Load Current (Arms)
mA
Ambient Temperature (°C)
Figure 5c — LS24D27C, LS60D27C, LS60D30C relays
LS 2
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2003 TELEDYNE RELAYS
LS\032003\Q2
Series LS
OUTPUT (LOAD) SPECIFICATION (continued)
ENVIRONMENTAL SPECIFICATION
Min
Max
Unit
Min
–40
Max
80
Unit
°C
Turn-On Time (60Hz)
All relays
Operating Temperature
Storage Temperature
Input-Output Isolation
Output-Case Isolation
8.3
ms
–40
120
°C
4000
3300
Vrms
Vrms
Turn-Off Time (60Hz)
All relays
8.3
500
440
ms
V/µs
Hz
NOTES:
1. MOV across the output recommended for non-resistive loads —
minimum size: 14mm
2. Maximum current based on size of the heat sink and the ambient
temperature.
3. For 800Hz applications, contact factory.
4. For additional/custom options, contact factory.
Off-State dv/dt
All relays
Operating Frequency
All relays
10
I2t for match fusing (<8.3ms)
LS24D16C
128
312
A2S
A2S
A2S
A2S
A2S
A2S
LS24D21C
LS60D22C
450
LS24D27C
1800
1800
5000
LS60D27C
LS60D30C
SURGE CURRENTS
200
250
200
150
100
50
Non-Repetitive
150
Non-Repetitive
100
50
Repetitive with initial Tj = 70°C
0
Repetitive with initial Tj = 70°C
0.01
0.10
1.00
10.0
t(s)
0
0.01
0.10
1.00
10.0
Figure 6a — L24D16C relay
t(s)
Figure 6b — LS24D21C relay
300
200
100
0
Non-Repetitive
700
600
500
400
300
200
100
Non-Repetitive
Repetitive with initial Tj = 70°C
0.01
0.10
1.00
10.0
t(s)
Figure 6c — LS60D22C relay
Repetitive with initial Tj = 70°C
1500
1000
500
0
0
0.01
0.1
1
t (s)
Temps
I (A)
60 s
20
100 s
15
Non-Repetitive
Long time overload @ Tj init = 45°C
Repetitive with initial Tj = 70°C
Figure 6d — LS60D27C, LS24D27C relays
0.01
0.1
1
10
t(s)
Figure 6e — LS60D30C relay
© 2003 TELEDYNE RELAYS
(800) 284-7007 • www.teledynerelays.com
LS 3
LS\032003\Q2
Series LS
MOUNTING EXAMPLES
Heat sinks references:
FW100: L=100mm about 4°C/W (1SSR) without ventilation (3.6°C/W with 4SSRs )
FW150: L=150mm about 3°C/W (1SSR) without ventilation (2.6°C/W with 6SSRs )
Supports additional heat sink if necessary
Clips reference: L19101
Thermal grease
0.311 ±006
(7.9 ± 0.15)
2
(51)
0.16 (4)
to maintain
isolation
Figure 7a — Thermal heat sinks with mounting clips; dimensions in inches (mm)
M3
1.04
(26.5)
0.16 (4) to
maintain
insulation
clips: L19100
Thermal grease
Printed circuit board
Figure 7b — Clips with screws on standard heat sinks; dimensions in inches (mm)
In each case, allow 0.16 in. (4mm) between the printed circuit board and the heat sink to keep a correct insulation
between input to output (0.16 in./4mm insulated washer). To maintain a good contact between the SSR and the heat
sink, use thermal grease.
LS 4
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2003 TELEDYNE RELAYS
LS\032003\Q2
Series LS
MECHANICAL SPECIFICATION
L19101 CLIP
±.01
1.18 (30)
=
=
M4
Figure 9a – Clip for FW100 and FW150 heat sinks
M4
Length:
±.01
FW100 = 3.94 (100)
FW150 = 5.9 (150)
= =
.31 (7.9)
Thermal grease
Relay
Figure 8 – FW100 and FW150 heat sinks;
dimensions in inches (mm)
.16 (4)
FW100 heat sink with Max Clip System*
Rth = 3.6°C/W (4 SSRs)
Rth = 4°C/W (1 SSR)
±.01
.07 (1.7)
FW150 heat sink with Max Clip System*
Rth = 2.6°C/W (4 SSRs)
Figure 9b – Mounting with L19101 clip;
dimensions in inches (mm)
Rth = 3°C/W (1 SSR)
*The Max Clip System of Aavid Thermalloy, patented worldwide
L19100 CLIP
Thermal grease
M3
Relay
.16 (4)
Figure 10a – Clips with
screws for other heat sinks
±.01
.07 (1.7)
Figure 10b – Mounting with L19100 clip;
dimensions in inches (mm)
NOTES
1. 0.16-inch (4mm) mounting washer must have correct
insulation between input to output.
© 2003 TELEDYNE RELAYS
(800) 284-7007 • www.teledynerelays.com
LS 5
LS\032003\Q2
HS1 HEAT SINK
Series LS
LS WITH HS1 HEAT SINK
+
Tolerances: 0.1
–
.87 (22)
.5 (12.7)
1.7 (43.6)
4
3
2
1
.25 (6.3)
.07 (1.73)
Ø1
.5 (12.7)
.2 (5.08)
.31 (7.83)
.4 (10.16)
Figure 11 – LS with HS1
WEIGHT:
1.06 oz. (30g)
Top view
INPUT (CONTROL) SPECIFICATION
Min
Max
Units
.1 (2.54)
Control Range
LS24D16C-HS1
Hole Ø 1.6
4
4
8
14
14
32
Vdc
Vdc
Vdc
Figure 12 — LS relays with HS1;
dimensions in inches (mm)
LS60D22C-HS1
LS24D16N-HS1
LOAD CURRENT DERATING CURVE
Input Current Range
LS24D16C-HS1
LS60D22C-HS1
LS24D16N-HS1
26
24
22
20
18
16
14
12
6.5
6.5
3.5
30
30
18
mAdc
mAdc
mAdc
Forced air cooling with
heat sink temperature 85°C max
10
8
Must Turn-Off Voltage
All relays
6
4
2
0
Convection cooling
1
Vdc
0
10
20
30
40
50
60
70
80
90
100
Input Resistance (Typical)
LS24D16C-HS1
Ambient Temperature (°C)
440
440
Ohms
Ohms
Ohms
Figure 13a — LS24D16X-HS1 relays
LS60D22C-HS1
26
LS24D16N-HS1
1640
24
22
20
18
16
14
12
Forced air cooling with
heat sink temperature 85°C max
10
8
6
4
2
0
Convection cooling
0
10
20
30
40
50
60
70
80
90
100
Ambient Temperature (°C)
Figure 13b — LS60D22N-HS1 relays
LS 6
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2003 TELEDYNE RELAYS
LS\032003\Q2