SHP48N125R [TELEDYNE]

Phase-Angle Controller Solid-State Relays;
SHP48N125R
型号: SHP48N125R
厂家: TELEDYNE TECHNOLOGIES INCORPORATED    TELEDYNE TECHNOLOGIES INCORPORATED
描述:

Phase-Angle Controller Solid-State Relays

文件: 总7页 (文件大小:352K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
NEW Series SHP  
Output to 125A, 480 Vac  
Phase-Angle Controller Solid-State Relays  
FEATURES/BENEFITS  
• Phase angle controller — microcontroller inside  
• Analog switching  
• Overvoltage protection by varistor  
• Green LED for input visualization  
• IP20 touch-proof flaps  
• Designed in conformity with EN60947-4-3 (IEC947-4-3)  
and EN60950/VDE0805 (Reinforced Insulation)  
SHPXXNXXA relays  
SHPXXNXXR relays  
IP20 touch-  
proof flaps  
Removable input  
spring connectors  
Gray: Supply  
Orange: Analog input  
0–10V  
Part Number  
SHP24N50A  
SHP24N50R  
SHP48N75A  
SHP48N75R  
SHP48N125A  
SHP48N125R  
Load Voltage  
90–280Vac  
Load Current  
50A  
Control Range  
010Vdc  
4–20mA  
Also Requires  
8-30Vdc Supply  
8-30Vdc Supply  
8-30Vdc Supply  
90–280Vac  
50A  
200–480Vac  
200–480Vac  
200–480Vac  
200–480Vac  
75A  
010Vdc  
4–20mA  
75A  
125A  
010Vdc  
4–20mA  
125A  
ELECTRICAL SPECIFICATIONS  
(+25°C ambient temperature unless otherwise specified)  
ELECTRICAL SPECIFICATIONS  
(+25°C ambient temperature unless otherwise specified)  
INPUT (CONTROL) SPECIFICATIONS  
SHPXXNXXA RELAYS  
INPUT (CONTROL) SPECIFICATIONS  
SHPXXNXXR RELAYS  
Min  
8
Max  
30  
Units  
V
Min  
4
Max  
20  
Units  
mA  
V
Control Voltage  
Control Current Range  
Voltage Range  
Supply Current  
12  
mA  
V
-0.6  
7.5  
Reverse Supply Voltage  
Analog Voltage Range  
Analog Input Current  
Reverse Analog Voltage  
Analog Input Impedance (Typ.)  
30  
0
10  
V
Dynamic Impedance  
SHP24N50R  
100  
30  
μA  
V
>100  
150  
mΩ  
mΩ  
mΩ  
SHP48N75R  
120  
kΩ  
SHP48N125R  
150  
Reverse Polarity Protection  
Input Current  
Yes  
50  
mA  
© 2009 TELEDYNE RELAYS  
(800) 284-7007 • www.teledynerelays.com  
SHP Page 1  
SHP\012009\Q1  
NEW Series SHP  
Output to 125A, 480 Vac  
Phase-Angle Controller Solid-State Relays  
TYPICAL APPLICATION  
MECHANICAL SPECIFICATION  
1.77  
(45) max  
Phase  
Neutral  
Analog input  
0-10Vdc  
Supply  
8-30Vdc  
Ø0.185  
(4.7)  
1.18  
(30) max  
1.10 (28)  
Load  
1/L1  
2/T1  
Control  
Supply  
+
+
Figure 1a — SHPXXNXXA relays  
Phase  
Neutral  
Dimensions in inches (mm)  
Weight: 2.29 oz. (65g)  
1.32  
(33.6)  
Figure 2a — SHPXXNXXA relays  
Analog control  
4-20mA  
1.77 (45) max  
Ø4.7  
Load  
1.18  
(30) max  
1.10 (28)  
M5  
Figure 1b — SHPXXNXXR relays  
1/L1  
2/T1  
3/A1  
4/A2  
1.00 (25.4)  
M4  
Dimensions in inches (mm)  
Weight: 2.29 oz. (65g)  
Figure 2b — SHPXXNXXR relays  
SHP Page 2  
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE  
© 2009 TELEDYNE RELAYS  
SHP\012009\Q1  
NEW Series SHP  
Output to 125A, 480 Vac  
Phase-Angle Controller Solid-State Relays  
ELECTRICAL SPECIFICATIONS  
OUTPUT (LOAD) SPECIFICATIONS (Continued)  
(+25°C ambient temperature unless otherwise specified)  
Min  
Max  
Units  
OUTPUT (LOAD) SPECIFICATIONS  
Non-Repetitive Overload Current  
SHP24N50A  
Min  
Max  
Units  
550  
550  
720  
720  
A
A
A
A
A
A
Operating Range  
SHP24N50A  
SHP24N50R  
SHP48N75A  
SHP48N75R  
SHP24N50R  
90  
280  
280  
480  
480  
480  
480  
Vrms  
Vrms  
Vrms  
Vrms  
Vrms  
Vrms  
SHP48N75A  
1000  
1000  
2000  
2000  
1200  
1200  
2200  
2200  
90  
SHP48N75R  
200  
200  
200  
200  
SHP48N125A  
SHP48N125R  
SHP48N125A  
SHP48N125R  
On-State Voltage Drop  
0.9  
V
Peak Voltage (VDR Clamping)  
SHP24N50A  
On-State Dynamic Resistance  
SHP24N50A  
600  
600  
Vpeak  
Vpeak  
Vpeak  
Vpeak  
Vpeak  
Vpeak  
12  
12  
4.5  
4.5  
2
mΩ  
mΩ  
mΩ  
mΩ  
mΩ  
mΩ  
SHP24N50R  
SHP24N50R  
SHP48N75A  
1200  
1200  
1200  
1200  
SHP48N75A  
SHP48N75R  
SHP48N75R  
SHP48N125A  
SHP48N125A  
SHP48N125R  
SHP48N125R  
2
Latching Voltage  
SHP24N50A  
SHP24N50R  
SHP48N75A  
SHP48N75R  
SHP48N125A  
SHP48N125R  
Output Power Dissipation  
(Max)  
0.9x0.9xI + 0.012xI2  
W
10  
10  
20  
10  
20  
20  
V
V
V
V
V
V
Off-State Leakage Current  
SHP24N50A  
2
1
2
1
2
1
mA  
mA  
mA  
mA  
mA  
mA  
SHP24N50R  
SHP48N75A  
SHP48N75R  
Load Current Range (See Fig. 5)  
SHP24N50A  
SHP48N125A  
SHP48N125R  
0.1  
0.1  
0.1  
0.1  
0.1  
0.1  
50  
75  
Arms  
Arms  
Arms  
Arms  
Arms  
Arms  
SHP24N50R  
SHP48N75A  
125  
50  
Init Time (60 Hz)  
83.3  
16.6  
52.3  
ms  
ma  
SHP48N75R  
Delay Time (60 Hz)  
SHP48N125A  
75  
Rise, Fall Time (60 Hz)  
Operating Frequency  
Off-State dv/dt  
ma  
SHP48N125R  
125  
40  
70  
Hz  
500  
V/μs  
A/μs  
Maximum di/dt (Non-Repetitive)  
50  
© 2009 TELEDYNE RELAYS  
(800) 284-7007 • www.teledynerelays.com  
SHP Page 3  
SHP\012009\Q1  
NEW Series SHP  
Output to 125A, 480 Vac  
Phase-Angle Controller Solid-State Relays  
OUTPUT (LOAD) SPECIFICATIONS (Continued)  
GENERAL SPECIFICATIONS  
(+25°C ambient temperature unless otherwise specified)  
Min  
Max  
Units  
ENVIRONMENTAL SPECIFICATIONS  
I2t for fuse matching (<10ms)  
SHP24N50A  
Min  
–40  
–40  
40  
Max  
+100  
+125  
85  
Units  
°C  
2500  
2500  
7200  
7200  
7200  
7200  
A2s  
A2s  
A2s  
A2s  
A2s  
A2s  
Operating Temperature  
Storage Temperature  
Ambient Humidity  
SHP24N50R  
°C  
SHP48N75A  
%
SHP48N75R  
Input-Output Isolation  
Output-Case Isolation  
4000  
4000  
Vrms  
Vrms  
SHP48N125A  
SHP48N125R  
Insulation Resistance  
@500Vdc  
1000  
MΩ  
Conducted Immunity Level  
IEC/EN61000-4-4 (bursts)  
IEC/EN61000-4-5 (surge)  
Rated Impulse Voltage  
4000  
IP20  
1.5  
V
4kV criterion A  
4kV criterion A  
Protection Level (CEI529)  
Vibration (10–55 Hz according to CE168)  
Shock (according to CE168)  
mm  
g
30/50  
Internal Overvoltage Protection  
820(@1mA)  
V
Thermal Resistance (Junction to Case)  
SHP48NXXR  
0.5  
C°/W  
Housing Material  
Baseplate  
PA6 UL94VO  
Aluminum, nickel-plated  
TRANSFER CHARACTERISTIC  
2
SURGE CURRENT  
(Vload/Vac)  
600  
400  
200  
0
100%  
75%  
Non-Repetitive  
50%  
25%  
0%  
Repetitive with initial Tj = 70°C  
0.1  
0
1
10  
t(s)  
Figure 3a — 50A output current  
1500  
1000  
500  
0
0
0.3  
2.5  
5
7.5  
9.7 10  
Ve(V)  
Figure 4a — SHPXXNXXA  
Non-Repetitive  
2
(Vload/Vac)  
100%  
Repetitive with initial Tj = 70°C  
0
0.1  
1
10  
t(s)  
Figure 3b — 75A output current  
75%  
50%  
25%  
2000  
1500  
1000  
500  
0
Non-Repetitive  
Repetitive with initial Tj = 70°C  
0%  
0
0
0.1  
1
10  
4
8
12  
16  
20 Ic(mA)  
t(s)  
Figure 3c — 125A output current  
Figure 4b — SHP48NXXR  
SHP Page 4  
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE  
© 2009 TELEDYNE RELAYS  
SHP\012009\Q1  
NEW Series SHP  
Output to 125A, 480 Vac  
Phase-Angle Controller Solid-State Relays  
THERMAL CHARACTERISTICS  
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
0.75°C/W 0.55°C/W  
0.95°C/W  
Full on State  
1.1°C/W  
1.5°C/W  
2.1°C/W  
6°C/W  
50% on State  
0
0
0
5
10 15 20 25 30 35 40 45 50 55 60  
0
10 20 30 40 50 60 70 80 90 100  
Ambient Temperature (°C)  
Load Current (Arms)  
Figure 5a — 50A output power  
0.3°C/W  
0.55°C/W  
0.75°C/W  
110  
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
110  
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
0.95°C/W  
1.1°C/W  
Full on State  
1.5°C/W  
2.1°C/W  
6°C/W  
50% on State  
10 20 30 40 50 60 70 80 90  
0
10 20 30 40 50 60 70 80 90 100  
Load Current (Arms)  
Ambient Temperature (°C)  
Figure 5b — 75A output power  
0.2°C/W  
170  
160  
150  
140  
130  
120  
110  
100  
90  
80  
70  
60  
50  
0.3°C/W  
170  
160  
150  
140  
130  
120  
110  
100  
90  
0.55°C/W  
Full on State  
0.75°C/W  
0.95°C/W  
80  
70  
60  
50  
40  
30  
20  
10  
1.1°C/W  
1.5°C/W  
2.1°C/W  
6°C/W  
40  
30  
20  
10  
50% on State  
0
0
15 30 45 60 75 90 105 120 135 150  
0
10 20 30 40 50 60 70 80 90 100  
Load Current (Arms)  
Ambient Temperature (°C)  
Figure 5c — 125A output power  
© 2009 TELEDYNE RELAYS  
(800) 284-7007 • www.teledynerelays.com  
SHP Page 5  
SHP\012009\Q1  
NEW Series SHP  
Output to 125A, 480 Vac  
Phase-Angle Controller Solid-State Relays  
OPTIONAL CONNECTIONS  
CONTROL WIRING - SHPCCNXXA  
Connector  
WAGO 734  
Directly with wires,  
with or without ferrules  
With tips  
(ring terminals)  
Pluggable removable input  
spring connectors  
Minimum: AWG28  
Maximum: AWG14  
With clip  
CONTROL WIRING - SHPXXNXXR  
Number of Wires  
Screwdriver  
Type  
Recommended  
Torque  
1
2
Solid  
(no ferrule)  
Fine Stranded  
(with ferrule)  
Solid  
(no ferrule)  
Fine Stranded  
(with ferrule)  
M4  
N.m  
AWG18…AWG14  
AWG18…AWG14  
AWG18…AWG14  
AWG18…AWG14  
Pozidriv 2  
1.2  
POWER WIRING  
Number of Wires  
Screwdriver  
Type  
Recommended  
Torque  
1
2
Solid  
(no ferrule)  
Fine Stranded  
(with ferrule)  
Solid  
(no ferrule)  
Fine Stranded  
(with ferrule)  
M5  
N.m  
2
AWG16…AWG8  
AWG16…AWG10  
AWG16…AWG8  
AWG16…AWG10  
Pozidriv 2  
Power with tips  
Options  
Fastons: Call us  
W max = 12.6 mm  
AWG6 (16mm2)  
AWG4 (25mm2)  
Special kit for high current  
2
AWG2/AWG3  
(35mm2)  
AWG2 (35mm )  
2
AWG0 (50mm )  
AWG0/AWG1  
(50mm2)  
SHP Page 6  
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE  
© 2009 TELEDYNE RELAYS  
SHP\012009\Q1  
NEW Series SHP  
Output to 125A, 480 Vac  
Phase-Angle Controller Solid-State Relays  
Mounting  
HIPpak SSRs must be mounted on heat sinks. A large range of heat  
sinks is available. For heat-sink mounting, use thermal grease or a  
thermal pad with high conductibility specified by Teledyne.  
2–2.5°C/W  
Teledyne P/N FW151  
1.1°C/W  
Teledyne P/N FW108  
Thermal Pad  
Teledyne P/N –12  
© 2009 TELEDYNE RELAYS  
(800) 284-7007 • www.teledynerelays.com  
SHP Page 7  
SHP\012009\Q1  

相关型号:

SHP48N75A

Phase-Angle Controller Solid-State Relays
TELEDYNE

SHP48N75R

Phase-Angle Controller Solid-State Relays
TELEDYNE

SHP5

Single and dual output 3 to 5 Watt Wide input DC/DC converters
ARTESYN

SHP5-05D05

Single and dual output 3 to 5 Watt Wide input DC/DC converters
ARTESYN

SHP5-05D12

Single and dual output 3 to 5 Watt Wide input DC/DC converters
ARTESYN

SHP5-05D15

Single and dual output 3 to 5 Watt Wide input DC/DC converters
ARTESYN

SHP5-05S05

Single and dual output 3 to 5 Watt Wide input DC/DC converters
ARTESYN

SHP5-05S12

Single and dual output 3 to 5 Watt Wide input DC/DC converters
ARTESYN

SHP5-05S15

Single and dual output 3 to 5 Watt Wide input DC/DC converters
ARTESYN

SHP5-05S2V1

Single and dual output 3 to 5 Watt Wide input DC/DC converters
ARTESYN

SHP5-05S3V3

Single and dual output 3 to 5 Watt Wide input DC/DC converters
ARTESYN

SHP5-12D05

Single and dual output 3 to 5 Watt Wide input DC/DC converters
ARTESYN