SR75-2W [TELEDYNE]

0.75A, 300Vdc Optically Isolated, Short-Circuit Protected for AC or DC Loads DC Solid-State Relay;
SR75-2W
型号: SR75-2W
厂家: TELEDYNE TECHNOLOGIES INCORPORATED    TELEDYNE TECHNOLOGIES INCORPORATED
描述:

0.75A, 300Vdc Optically Isolated, Short-Circuit Protected for AC or DC Loads DC Solid-State Relay

输出元件 光电
文件: 总2页 (文件大小:204K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Series SR75-2  
0.75A, 300Vdc Optically Isolated, Short-Circuit Protected  
for AC or DC Loads DC Solid-State Relay  
Part Number* Relay Description  
SR75-2  
Solid-State Relay with Terminals for Through-Hole  
Mount  
SR75-2S  
Solid-State Relay with Terminals for Surface Mount  
*
A ‘W’ or ‘T’ suffix denoting the Teledyne reliability screening level,  
must be added to the part number.  
FEATURES/BENEFITS  
• Short-Circuit Protected: Prevents  
damage to system components,  
assemblies and system wiring. Can  
be connected to protect AC or DC  
loads (AC with diode bridge)  
ELECTRICAL SPECIFICATIONS  
(-55°C TO 105°C, Ambient Temperature Unless Otherwise Specified)  
INPUT (CONTROL) SPECIFICATIONS  
• Optical Isolation: Isolates control  
circuits from load transients  
Eliminates ground loops and signal  
ground noise  
Min Max Units  
Control Voltage Range (See Note 6)  
Input Current @ 5 Vdc (See Figure 1)  
Must Turn-On Voltage (See Note 7)  
Must Turn-Off Voltage  
3.8 32.0 Vdc  
11.0 mA  
• Low Off-State Leakage: For high off-  
state impedance  
• Switches High Voltages: To 300 Vdc  
• Switches High Currents: To 0.75 Adc  
3.8  
Vdc  
1.5 Vdc  
-32.0 Vdc  
• High Noise Immunity: Control signals  
isolated from switching noise  
Reverse Voltage Protection  
• High Dielectric Strength: For safety  
and for protection of control and  
signal level circuits  
OUTPUT (LOAD) SPECIFICATION  
Min Max Units  
300 Vdc  
DESCRIPTION  
Load Voltage Rating  
The SR75-2 solid-state relay utilizes a  
power FET switch that is protected  
against overload and short-circuit  
currents. The short-circuit protection  
feature not only provides protection  
should a short or overload occur while  
the relay is on, but will also provide  
protection should the relay be switched  
into a short. Once the protection trips  
the relay, it will remain off until reset by  
cycling the input control line. Using the  
SR75-2 to switch power sources and  
loads can prevent fires, damage to  
system assemblies and system wiring.  
The power FET output offers low “ON”  
resistance and can switch loads in  
either the high or the low side of the  
power line. The SR75-2 is packaged in  
a 16-pin DIP package with either  
surface-mount or through-hole mounting  
available.  
Transient Blocking Voltage  
Output Current Rating (See Figure 2)  
On Resistance (See Figure 3)  
Leakage Current at Rated Voltage  
Turn-On Time  
320 Vdc  
0.75 Adc  
2.0 Ohm  
100  
4.5  
0.5  
µA  
ms  
ms  
Turn-Off Time  
dV/dt @ 60V (See Note 8)  
Electrical System Spike (See Note 8)  
100 V/µs  
600 Vpk  
Output Capacitance @ 100 KHz, 25 Vdc (See Note 8) 250  
pF  
pF  
Input to Output Capacitance at 1 KHz (See Note 8)  
5
Dielectric Strength (See Note 8)  
Insulation Resistance (See Note 8)  
Junction Temperature  
1000  
108  
Vrms  
Ohm  
°C  
130  
Thermal Resistance (Junction to Ambient)  
Solderability (10 sec)  
90 °C/W  
260 °C  
© 2004 TELEDYNE RELAYS  
(800) 284-7007 • www.teledynerelays.com  
SR75-2 1  
SR75-2\062004\Q1  
Series SR75-2  
INPUT VOLTAGE (Vdc)  
CONTROL CURRENT VS VOLTAGE  
FIGURE 1  
LOAD CURRENT DERATING CURVE  
FIGURE 2 (SEE NOTE 5)  
2.0  
1.8  
1.6  
1.4  
1.2  
1.0  
0.8  
0.6  
0.4  
0.2  
0.0  
TRIP CURRENT VS TIME  
FIGURE 4  
WIRING CONFIGURATIONS  
R
S
RETURN  
LOAD  
–55  
-35  
-15  
5
25  
45  
65  
85  
105  
125  
16  
14  
12  
10  
JUNCTION TEMPERATURE (°C)  
TYPICAL ON RESISTANCE VS TJ  
FIGURE 3  
SR75-2  
V
CC  
1
3
5
8
+
+V  
LOAD  
MECHANICAL SPECIFICATIONS  
SHORT-CIRCUIT PROTECTED DC LOADS  
(SEE NOTES 3, 4 AND 6, FIGURE 3 AND 4)  
V BIAS = 5.0 VDC  
CTRL  
TTL  
16  
14  
12  
10  
SR75-2  
1
3
5
8
120  
Vac  
V BIAS = 5.0 VDC  
SHORT-CIRCUIT PROTECTED AC LOADS  
(SEE NOTE 6)  
NOTES:  
1. The input voltage is 5.0 Vdc for all tests unless otherwise  
specified.  
2. Reversing the output polarity when the relay is in overload or  
is sustaining a short circuit may cause permanent damage.  
3. Inductive loads must be diode suppressed.  
4. Loads may be switched in either the high side or the low side  
of the power source.  
5. Continuous load current rating is determined with relay  
mounted on a printed circuit card.  
6. For input voltage greater than 6.0 Vdc a series resistor must  
be used to limit the power dissipation on the input of the  
relay. The resistor value should be selected using the  
following equation:  
R = (VBIAS - 6 volts)/11mA  
7. Input transitions are to be less than 1 msec.  
8. Tested at 25°C ambient.  
• Operating Temperature Range  
–55°C to 105°C  
• Storage Temperature Range  
–55°C to 125°C  
• Weight: 2.0 grams maximum  
• Case: 16-pin Dual-In-Line (TO-116)  
• Case Material: Filled epoxy, self-  
extinguishing  
SR75-2 2  
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE  
© 2004 TELEDYNE RELAYS  
SR75-2\062004\Q1  

相关型号:

SR75-3

0.5A, 400 Vdc Optically Isolated
TELEDYNE

SR75-3S

0.5A, 400 Vdc Optically Isolated
TELEDYNE

SR750

7.5 AMPS. SCHOTTKY BARRIER RECTIFIERS
GOOD-ARK

SR750

SCHOTTKY BARRIER RECTIFIER
LUNSURE

SR750

SCHOTTKY BARRIER RECTIFIER
JINANJINGHENG

SR7500

75 AMP HIGH FREQUENCY TAB MOUNTED SOFT RECOVERY DIODES
DEC

SR7501

75 AMP HIGH FREQUENCY TAB MOUNTED SOFT RECOVERY DIODES
DEC

SR7502

75 AMP HIGH FREQUENCY TAB MOUNTED SOFT RECOVERY DIODES
DEC

SR7504

75 AMP HIGH FREQUENCY TAB MOUNTED SOFT RECOVERY DIODES
DEC

SR7506

75 AMP HIGH FREQUENCY TAB MOUNTED SOFT RECOVERY DIODES
DEC

SR751A103GTR

Ceramic Capacitor, Multilayer, Ceramic, 100V, 2% +Tol, 2% -Tol, C0G, -/+30ppm/Cel TC, 0.01uF, 4015,
KYOCERA AVX

SR751A153FTRTR2

Ceramic Capacitor, Multilayer, Ceramic, 100V, 1% +Tol, 1% -Tol, C0G, -/+30ppm/Cel TC, 0.015uF, 4015,
KYOCERA AVX