ST24A12-02 [TELEDYNE]

Single Output to 75A 600 Vac;
ST24A12-02
型号: ST24A12-02
厂家: TELEDYNE TECHNOLOGIES INCORPORATED    TELEDYNE TECHNOLOGIES INCORPORATED
描述:

Single Output to 75A 600 Vac

文件: 总4页 (文件大小:130K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Series ST  
Single Output to 75A 600 Vac  
AC/DC Control  
Part Numbers  
Package &  
Line  
Switch  
Type2  
Output  
Feature3  
Chip Type  
Voltage1  
24  
Current  
ST  
D
12  
25  
40  
50  
75  
25  
50  
25  
-02  
-16  
48  
ST  
ST  
24  
48  
A
A
-22  
FEATURES/BENEFITS  
Part Number Example: ST48A25-22  
• Industry standard package  
• Internal MOV (certain models)  
• Control LED (certain models)  
• AC or DC control available  
• Excellent thermal performance  
• Tight zero-cross window for low EMI  
• High immunity to surges  
NOTES  
1) Line Voltage (nominal): 24 = 240 Vac; 48 = 480 Vac  
2) Switch Type: D = Zero-cross turn-on; A = AC control,  
Zero-cross turn-on  
3) Feature: -02 = Control LED: Standard on all ST48D  
Only available on ST24D 12A and 40A (standard)  
-16 = Internal MOV: Available only on ST24D 25A and 50A  
-22 = 24 Vac Control  
MECHANICAL SPECIFICATION  
1.06 (27)  
(±.02)  
DESCRIPTION  
The Series ST single-phase relays are designed for  
high-power applications. The design incorporates an  
SCR or triac output. The Series ST relays utilize optical  
isolation to protect the control from load transients.  
Control LED is available on certain models.All Series  
ST relays are zero crossing. Internal MOV is also  
available on ST24D 25A and 50A models.  
.9 (22.8)  
1.1 (28)  
.77 (19.6)  
Ø.19 (Ø4.7)  
M4  
1~  
2~  
3+  
APPLICATIONS  
• Heating control  
4-  
• Industrial and process control  
• On/Off controls of AC equipment  
1.02 (25.8)  
1 (25.4)  
1.75 (44.5)  
APPROVALS  
All models are UL recognized.  
UL File Number: E128555.  
TOLERANCE: ±.01 (0.3)  
WEIGHT: 3.18 oz. (90g)  
M3  
Figure 1 — ST relays, dimensions in inches (mm)  
TYPICAL APPLICATION  
Line  
Voltage  
Line  
Voltage  
Line  
Voltage  
Line Protection  
Line Protection  
1
Line Protection  
1
4–  
3+  
4–  
3+  
1
4–  
Control  
Control  
+
Control  
+
LED  
3+  
+
2
2
2
• 1–2 can be changed  
• SSR must be mounted on a heat sink  
• 1–2 can be changed  
• SSR must be mounted on a heat sink  
• 1–2 can be changed  
• SSR must be mounted on a heat sink  
Load  
Load  
Load  
Figure 2a — ST relays  
Figure 2b — ST -02 option relays  
Figure 2c — ST -16 option relays  
© 2003 TELEDYNE RELAYS  
(800) 284-7007 • www.teledynerelays.com  
ST 1  
ST\032003\Q1  
Series ST  
INPUT (CONTROL) SPECIFICATION  
CONTROL CHARACTERISTICS  
30  
28  
26  
24  
22  
20  
18  
16  
14  
12  
10  
8
Input Type  
Min  
Max  
Units  
Control Range  
ST24  
D
A
D
A
4
90  
5
30  
Vdc  
240 Vac/Vdc  
ST48  
30  
80  
Vdc  
17  
Vac/Vdc  
6
4
2
0
Input Current Range  
ST24D  
0
2
4
6
8
10 12 14 16 18 20 22 24 26 28 30  
3
4
30  
48  
8
mA  
mA  
mA  
mA  
mA  
Control Voltage (V)  
ST24DXX-02  
ST24A  
Figure 3a — ST24D relays  
3
ST48D  
5
46  
26  
50  
45  
40  
ST48A25-22  
5.6  
35  
30  
25  
Must Turn-Off Voltage  
ST  
D
A
A
1
15  
3
Vdc  
Vac  
Vac  
20  
15  
ST24  
ST48  
10  
5
0
0
2
4
6
8
10 12 14 16 18 20 22 24 26 28 30  
Input Resistance (Typical)  
Control Voltage (V)  
ST  
ST  
ST  
D
D-02  
A
1000  
600  
Ohms  
Ohms  
Ohms  
Figure 3b — ST -02 relays  
8
6
4
2
0
3000  
Reverse Voltage Protection  
S
S
D
A
30  
V
NA  
OUTPUT (LOAD) SPECIFICATION  
Input Type  
Min  
Max  
Units  
0
20 40 60 80 100 120 140 160 180 200 220 240  
Operating Range  
ST24  
Control Voltage (V)  
12  
24  
280  
600  
Vrms  
Vrms  
Figure 3c — ST24A relays  
ST48  
30  
25  
20  
15  
10  
5
Peak Voltage  
ST24  
600  
Vpeak  
ST48  
1200 Vpeak  
Load Current Range (Resistive)  
12A output current  
25A output current  
40A output current  
50A output current  
75A output current  
.005  
12  
25  
40  
50  
75  
Arms  
Arms  
Arms  
Arms  
Arms  
0
0
10  
20  
30  
40  
50  
60  
70  
80  
.005  
.005  
.005  
.005  
Control Voltage (V)  
Figure 3d — ST24A25-22  
ST 2  
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE  
© 2003 TELEDYNE RELAYS  
ST\032003\Q1  
Series ST  
OUTPUT (LOAD) SPECIFICATION (continued)  
SURGE CURRENT  
150  
100  
50  
Input Type  
Min  
Max  
Units  
Non-Repetitive  
Maximum Surge Current Rating (Non-Repetitive)  
12A output current  
25A output current  
40A output current  
50A output current  
75A output current  
120  
240  
A
A
A
A
A
Repetitive with initial T  
j
= 70°C  
350  
0
0.01  
0.01  
0.01  
0
0.1  
1
10  
550  
t(s)  
Figure 4a — 12A output current  
1000  
250  
200  
150  
100  
50  
On-State Voltage Drop  
12A output current  
25A output current  
40A output current  
50A output current  
ST48D50-02  
1.3  
1.2  
V
V
V
V
V
V
Non-Repetitive  
1.4  
Repetitive with initial T  
j
= 70°C  
0
1.45  
1.4  
0.1  
1
10  
10  
10  
t(s)  
Figure 4b — 25A output current  
75A output current  
1.4  
400  
300  
200  
100  
0
Zero-Cross Window (Typical)  
Non-Repetitive  
S
D/A  
±12  
Vac  
mA  
Repetitive with initial T  
j
= 70°C  
Off-State Leakage Current (60Hz)  
All relays  
0.1  
1
t(s)  
3
Figure 4c — ST24D40-02  
Turn-On Time (60 Hz)  
600  
400  
200  
0
ST  
ST  
D
A
8.3  
ms  
ms  
24.9  
Non-Repetitive  
Repetitive with initial Tj = 70°C  
Turn-Off Time (60 Hz)  
0.1  
1
ST  
ST  
D
A
8.3  
ms  
ms  
t(s)  
24.9  
Figure 4d — 50A output current and ST48D40-02  
1500  
Off-State dv/dt  
All relays  
500  
50  
V/µs  
A/µs  
Hz  
1000  
500  
0
Non-Repetitive  
Maximum di/dt (Non-Repetitive)  
All relays  
Repetitive with initial Tj = 70°C  
0.01  
0.1  
1
10  
t(s)  
Figure 4e — 75A output current  
Operating Frequency Range  
All relays  
0.1  
440  
NOTES:  
1. Electrical specifications at 25°C unless otherwise specified.  
2. For 800Hz applications, contact factory.  
3. For additional/custom options, contact factory.  
OPTIONAL ADD-ONS  
Please order add-ons separately:  
• -12 — Thermal pad installed.  
• -14 — Plastic touch-proof cover.  
© 2003 TELEDYNE RELAYS  
(800) 284-7007 • www.teledynerelays.com  
ST 3  
ST\032003\Q1  
Series ST  
T case  
max (°C)  
OUTPUT (LOAD) SPECIFICATION (continued)  
0.95°C/W  
40  
35  
30  
25  
20  
15  
10  
5
70  
1.1  
0
.7  
Input Type  
I2t for Match Fusing (<8.3ms)  
12A output current  
Min  
Max  
Units  
°
5
C/W  
°
C
/W  
Full on state  
80  
2.2  
°
C
/W  
90  
72  
A2S  
A2S  
A2S  
A2S  
A2S  
A2S  
100  
50% duty cycle  
ST24 25A output current  
ST48 25A output current  
40A output current  
288  
6°C/W  
265  
612  
0
50A output current  
1500  
5000  
0
2
4
6
8
10 12 14 16 18 20 22 24 26  
0
10 20 30 40 50 60 70 80 90 100 110 120  
Load Current (Arms)  
Ambient Temperature (°C)  
75A output current  
Figure 5c — 25A output current  
ENVIRONMENTAL SPECIFICATION  
T case  
max (°C)  
60  
55  
50  
45  
40  
35  
30  
25  
20  
15  
10  
5
Min  
–40  
Max  
100  
100  
Units  
°C  
65  
70  
75  
80  
85  
90  
95  
0.75  
0.95  
°
°
1.1  
C/W  
C/W  
Full on state  
°
C/W  
Storage Temperature  
Operating Temperature  
Input-Output Isolation  
Output-Case Isolation  
12A output current  
25A output current  
ST24D40-02  
1.6  
2
°
C/W  
–40  
°C  
.
2
°
C
/
W
4000  
Vrms  
50% duty cycle  
100  
6
°
C/W  
2500  
2500  
2500  
3300  
3300  
3300  
Vrms  
Vrms  
Vrms  
Vrms  
Vrms  
Vrms  
0
0
2
4
6
8
10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40  
Load Current (Arms)  
0
10 20 30 40 50 60 70 80 90 100 110 120  
Ambient Temperature (°C)  
ST48D40-02  
Figure 5d — ST24D40-02  
50A output current  
75A output current  
T case  
max (°C)  
100  
70  
75  
0
0.55  
.
3
°
C
90  
80  
°
C/W  
/
W
0
.
9
80  
85  
5
THERMAL CHARACTERISTICS  
°
C
/
W
T case  
70  
60  
Full on state  
max (°C)  
90  
95  
1.6°C/W  
75  
80  
85  
90  
95  
20  
18  
16  
14  
12  
10  
8
1
1.1°C/W  
2.2°C/W  
.
6
°
C
50  
40  
/
W
100  
50% duty cycle  
4°C/W  
6°C/W  
Full on state  
30  
20  
10  
0
100  
50% duty cycle  
0
5
10 15 20 25 30 35 40 45 50 55 60  
Load Current (Arms)  
0
10 20 30 40 50 60 70 80 90 100 110 120  
6
Ambient Temperature (°C)  
4
2
Figure 5e— 50A output current and ST48D40-02  
0
0
1
2
3
4
5
6
7
8
9
10  
11 12  
0
10 20 30 40 50 60 70 80 90 100 110 120  
Load Current (Arms)  
Ambient Temperature (°C)  
T case  
max (°C)  
130  
120  
Figure 5a — 12A output current  
70  
75  
80  
85  
0
.5  
5
110  
°
C
T case  
max (°C)  
/W  
100  
90  
Full on state  
140  
130  
120  
110  
100  
90  
70  
0
.5  
90  
5
80  
70  
60  
50  
40  
30  
20  
75  
80  
85  
90  
95  
100  
°
C
/W  
95  
50% duty cycle  
Full on state  
100  
2
80  
.2  
°
C
/W  
70  
50% duty cycle  
60  
50  
10  
0
40  
30  
0
10 20 30 40 50 60 70 80 90  
Load Current (Arms)  
0
10 20 30 40 50 60 70 80 90 100 110 120  
20  
Ambient Temperature (°C)  
10  
Figure 5f — 75A output current  
0
0
10 20 30 40 50 60 70 80 90 100 110  
Load Current (Arms)  
0
10 20 30 40 50 60 70 80 90 100 110120  
Ambient Temperature (°C)  
Figure 5b — ST48D12-02  
ST 4  
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE  
© 2003 TELEDYNE RELAYS  
ST\032003\Q1  

相关型号:

ST24A12-16

Single Output to 75A 600 Vac
TELEDYNE

ST24A12-22

Single Output to 75A 600 Vac
TELEDYNE

ST24A25-02

Single Output to 75A 600 Vac
TELEDYNE

ST24A25-16

Single Output to 75A 600 Vac
TELEDYNE

ST24A25-22

Single Output to 75A 600 Vac
TELEDYNE

ST24A40-02

Single Output to 75A 600 Vac
TELEDYNE

ST24A40-16

Single Output to 75A 600 Vac
TELEDYNE

ST24A40-22

Single Output to 75A 600 Vac
TELEDYNE

ST24A50-02

Single Output to 75A 600 Vac
TELEDYNE

ST24A50-16

Single Output to 75A 600 Vac
TELEDYNE

ST24A50-22

Single Output to 75A 600 Vac
TELEDYNE

ST24A75-02

Single Output to 75A 600 Vac
TELEDYNE