114-94040 [TE]

AMP High Current Connectors and Headers;
114-94040
型号: 114-94040
厂家: TE CONNECTIVITY    TE CONNECTIVITY
描述:

AMP High Current Connectors and Headers

文件: 总27页 (文件大小:898K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
108-94268  
Product  
Specification  
08 MARCH 2021 REV H  
Class 1  
HVP800 2PHI AND 3PHI 90DEG  
AMP+ High Current Connectors and Headers  
© 2021 TE Connectivity family of companies  
All Rights Reserved  
| Indicates Change  
 
1 of 27  
*Trademark. TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Other logos, product, and/or company names may be trademarks of their respective owners.  
108-94268  
1.  
SCOPE ..........................................................................................................................5  
ANWENDUNGSBEREICH .....................................................................................................5  
1.1 Introducing ..................................................................................................................5  
Einführung ...........................................................................................................................5  
1.2 Content .......................................................................................................................5  
Inhalt....................................................................................................................................5  
1.3 Qualification ................................................................................................................5  
Qualifikation .........................................................................................................................5  
2.  
APPLICABLE DOCUMENTS........................................................................................6  
ANWENDBARE UNTERLAGEN............................................................................................6  
2.1 TE Connectivity Documents........................................................................................6  
TE Connectivity Unterlagen .................................................................................................6  
2.1.1 General Requirements..........................................................................................6  
Generelle Anforderungen..................................................................................................6  
2.1.2 Customer drawings ...............................................................................................6  
Kundenzeichnungen .........................................................................................................6  
2.1.3 Specifications........................................................................................................8  
Spezifikationen..................................................................................................................8  
2.2 Other Documents........................................................................................................9  
Allgemeine Unterlagen.........................................................................................................9  
3.  
REQUIREMENTS........................................................................................................10  
ANFORDERUNGEN.............................................................................................................10  
3.1 Design and Construction...........................................................................................10  
Entwurf und Konstruktion...................................................................................................10  
3.2 Material .....................................................................................................................10  
Werkstoff............................................................................................................................10  
3.3 Ratings......................................................................................................................10  
Leistungsmerkmale............................................................................................................10  
3.4 Performance and Test Description............................................................................11  
Leistung und Testdurchführung .........................................................................................11  
3.5 Test Requirements and Procedures Summary .........................................................12  
Testanforderungen und Testergebnisse ............................................................................12  
3.6 Additional Test Procedures and Test Results ...........................................................18  
Zusätzliche Testdurchführungen und Testergebnisse .......................................................18  
4.  
QUALITY ASSURANCE PROVISIONS ......................................................................19  
QUALITÄTSSICHERUNGSMASSNAHMEN .......................................................................19  
4.1 Qualification Testing .................................................................................................19  
Qualifikationsprüfung .........................................................................................................19  
4.2 Requalification Testing..............................................................................................20  
2 of 27  
Rev H  
108-94268  
Requalifikationsprüfung .....................................................................................................20  
4.2.1 Acceptance .........................................................................................................20  
Abnahme ........................................................................................................................20  
4.2.2 Quality Conformance Inspection.........................................................................20  
Prüfung der Qualitätskonformität ....................................................................................20  
5.  
APPENDIX...................................................................................................................21  
ANHANG ..............................................................................................................................21  
5.1 Housing influence on derating: 2pos connector ........................................................21  
Gehäuseeinfluss auf das Derating: 2pol-Steckverbinder ...................................................21  
5.2 Housing influence on derating: 3pos connector ........................................................22  
Gehäuseeinfluss auf das Derating: 3pol-Steckverbinder ...................................................22  
5.3 Dynamic load ............................................................................................................24  
Dynamische Beanspruchung .............................................................................................24  
5.4 Contact engagement length......................................................................................25  
Kontaktüberdeckung..........................................................................................................25  
5.5 Strain Relief ..............................................................................................................27  
Leitungsabfangung ............................................................................................................27  
3 of 27  
Rev H  
108-94268  
LIST OF FIGURES  
Figure 1: Derating and temperature rise 2pos 25mm² Coroplast-Part-No. 9-2611.............21  
Figure 2: Derating and temperature rise 2pos 35mm² Coroplast-Part-No. 9-2611.............21  
Figure 3: Derating and temperature rise 2pos 50mm² Coroplast-Part-No. 9-2611.............22  
Figure 4: Derating and temperature rise 2pos 35mm² kromberg & Schubert - ..................22  
Figure 5: Derating and temperature rise 3pos 25mm² Coroplast-Part-No. 9-2611.............23  
Figure 6: Derating and temperature rise 3pos 35mm² Coroplast-Part-No. 9-2611.............23  
Figure 7: Derating and temperature rise 3pos 50mm² Coroplast-Part-No. 9-2611.............24  
Figure 8: Vibration device (exemplary view at 2pos. connector)...........................................25  
Figure 9: Contact engagement length...................................................................................26  
Figure 10: Recommended requirement for strain reliefs.......................................................27  
ABBILDUNGSVERZEICHNIS  
Abbildung 1: Derating und Stromerwärmung 2pol 25mm² Coroplast-Nr. 9-2611...............21  
Abbildung 2: Derating und Stromerwärmung 2pol 35mm² Coroplast-Nr. 9-2611...............21  
Abbildung 3: Derating und Stromerwärmung 2pol 50mm² Coroplast-Nr. 9-2611...............22  
Abbildung 4: Derating und Stromerwärmung 2pol 35mm² kromberg & Schubert ..............22  
Abbildung 5: Derating und Stromerwärmung 3pol 25mm² Coroplast-Nr. 9-2611...............23  
Abbildung 6: Derating und Stromerwärmung 3pol 35mm² Coroplast-Nr. 9-2611...............23  
Abbildung 7: Derating und Stromerwärmung 3pol 50mm² Coroplast-Nr. 9-2611...............24  
Abbildung 8: Vibrationsvorrichtung (exemplarische Darstellung mit 2 pol. Stecker) .............25  
Abbildung 9: Kontaktüberdeckung ........................................................................................26  
Abbildung 10: Empfohlene Anforderungen Leitungsabfangung............................................27  
LIST OF TABLES  
Table 1: General Requirements..............................................................................................6  
Table 2: Customer drawings ...................................................................................................6  
Table 3: TE-Specifications......................................................................................................8  
Table 4: References................................................................................................................9  
Table 5: Product Ratings ......................................................................................................10  
Table 6: Test Requirements and procedures Summary........................................................12  
Table 7: Additional test requirements....................................................................................18  
TABELLENVERZEICHNIS  
Tabelle 1: Generelle Anforderungen.......................................................................................6  
Tabelle 2: Kundenzeichnungen ..............................................................................................6  
Tabelle 3: TE-Spezifikationen .................................................................................................8  
Tabelle 4: Referenzen.............................................................................................................9  
Tabelle 5: Produktmerkmale .................................................................................................10  
Tabelle 6: Testanforderung und Ergebnisse.........................................................................12  
Tabelle 7: Zusätzliche Testanforderungen............................................................................18  
4 of 27  
Rev H  
108-94268  
Only the German version is authoritative.  
Maßgebend ist der deutsche Text.  
1.  
SCOPE  
ANWENDUNGSBEREICH  
1.1  
Introducing  
Einführung  
TE Connectivity’s touch-proof 2-3 position high current connector HVP800 and header are designed to  
meet WG 4.3.3, LV215-1 specifications, for a metric wire size range from 16mm² up to 50mm² acc. to  
LV216-2.  
With a 90deg cable outlet incorporates the sealed connector system two or three (2-3pos) 8mm power  
contacts and an integrated High Voltage Interlock (HVIL) System. The HVP800 connector is available  
for four different keying or polarizing configurations and incorporates 360deg conductive EMI shields  
to reduce radiated emissions in the application. Assembly is simplified with a lever assist for low  
insertion force and the housings are molded in orange to denote a high voltage system.  
TE Connectivity’s berührgeschützter 2-3pol. Hochstromsteckverbinder HVP800 und Stiftleiste sind nach der  
Designrichtlinie LV215-1 des AK 4.3.3 entwickelt, für einen metrischen Leitungsquerschnittsbereich von 16mm² bis  
zu 50mm² gem. LV216-2.  
Das gedichtete Stecksystem beinhaltet mit einem 90° Leitungsabgang zwei oder drei (2-3pol) 8mm  
Leistungskontakte und ein integriertes Hochvolt-Interlock (HVIL) System. Zur Reduzierung der abgestrahlten  
Emissionen ist der HVP800 mit 360°-Schirmblechen ausgeführt und ist für vier Kodierungen und Polarisierungen  
erhältlich. Die Montage wird durch den Einsatz eines Hebels bei geringen Steckkräften vereinfacht, sowie zur  
Kennzeichnung der Hochvoltanwendung die Gehäuse in orange ausgeführt sind.  
1.2  
Content  
Inhalt  
This specification covers performance, tests and quality requirements for the TE Connectivity 2-3  
position high current connector HVP800 with 90deg Plug and Header assembly.  
Please note, performance, tests and quality requirements to the contact systems are not part of this  
specification, but are included by the validation of the connector system.  
Diese Spezifikation beschreibt die Eigenschaften, Tests und Qualitätsanforderungen für den TE Connectivity 2-  
3pol Steckverbinder HVP800 mit 90° Buchsengehäuse und Stiftleiste.  
Anmerkung, Eigenschaften, Tests und Qualitätsanforderungen an die verwendeten Kontaktsysteme sind nicht  
Bestandteil dieser Spezifikation, jedoch im Umfang der Validation des Stecksystems enthalten.  
1.3  
Qualification  
Qualifikation  
When tests are performed the following specifications and standards shall be used. All inspections  
shall be performed using the applicable inspection plan and customer drawing.  
Die nachfolgenden Prüfungen sind nach den genannten Richtlinien und Normungen einzuhalten und müssen nach  
den zugehörigen Prüfplänen und Kundenzeichnungen durchgeführt werden.  
5 of 27  
Rev H  
108-94268  
2.  
APPLICABLE DOCUMENTS  
ANWENDBARE UNTERLAGEN  
The following mentioned documents are part of this specification. Unless otherwise specified, the  
latest edition of the documents applies. In the event of conflict between the requirements of this  
specification and the information contained in the referenced documents, this specification shall take  
precedence (exempt from documents to the contact systems).  
Die nachfolgenden Unterlagen, sofern darauf verwiesen wird, sind Teil dieser Spezifikation. Falls nicht anders  
spezifiziert sind die jeweils letztgültigen Dokumente anzuwenden. Im Falle des Widerspruches zwischen dieser  
Spezifikationen oder Informationen von anderen technischen Dokumentationen, hat diese Spezifikation Vorrang  
(ausgenommen Kontaktspezifische Dokumente).  
2.1  
TE Connectivity Documents  
TE Connectivity Unterlagen  
2.1.1 General Requirements  
Generelle Anforderungen  
Table 1: General Requirements  
Tabelle 1: Generelle Anforderungen  
Requirements  
Description  
Requirements  
Beschreibung  
TEC-109-1  
Rev. J  
General Requirements for Test Specifications  
Generelle Anforderungen für Testspezifikationen  
2.1.2 Customer drawings  
Kundenzeichnungen  
Table 2: Customer drawings  
Tabelle 2: Kundenzeichnungen  
2pos Receptacle housing  
2pol Buchsengehäuse  
2 Pos, 8mm HV, REC HSG 90°, Assy  
2 pol. 8mm HV, REC HSG 90°, Assy  
2141154  
2141160  
2282334  
2 Pos. 8mm HV, REC HSG 90° Kit, Overview pre-serial parts, not for sale  
2 pol. 8mm HV, REC HSG 90° Kit, Übersicht Kleinserienteile, nicht zum Verkauf  
2 Pos. 8mm HV, REC HSG 90° Kit, Overview serial parts, not for sale  
2 pol. 8mm HV, REC HSG 90° Kit, Übersicht Serienteile, nicht zum Verkauf  
3pos Receptacle housing  
3pol Buchsengehäuse  
3 Pos, 8mm HV, REC HSG 90°, Assy  
3 pol. 8mm HV, REC HSG 90°, Assy  
2141166  
6 of 27  
Rev H  
108-94268  
3 Pos. 8mm HV, REC HSG 90° Kit, Overview pre-serial parts, not for sale  
3 pol. 8mm HV, REC HSG 90° Kit, Übersicht Kleinserienteile, nicht zum Verkauf  
2141167  
3 Pos. 8mm HV, REC HSG 90° Kit, Overview serial parts, not for sale  
3 pol. 8mm HV, REC HSG 90° Kit, Übersicht Serienteile, nicht zum Verkauf  
22823356  
2pos Pinheader  
2pol Stiftwanne  
2 Pos. Dia 8mm Pin housing, Assy  
2 pol. Rundkontakt 8mm Stiftwanne, Assy  
2141227  
2349467  
2 Pos. Dia 8mm Pin housing, Assy (V0 version)  
2 pol. Rundkontakt 8mm Stiftwanne, Assy  
3pos Pinheader  
3pol Stiftwanne  
3 Pos. Dia 8mm Pin housing, Assy  
3 pol. Rundkontakt 8mm Stiftwanne, Assy  
2141230  
Single Components  
Einzelkomponenten  
Cover, Seal  
Abdeckkappe, Dichtung  
2141155  
2141156  
2141157  
2141158  
2141159  
2141211  
2141212  
2141145  
1418754  
Single Wire Seal  
Einzelleitungsdichtung  
Shield Crimp Ferrule  
Schirmcrimphülse  
Shielding EMC  
Schirmung, EMV  
Finger protection cap  
Fingerschutz  
Deep drawn socket, 90 deg, Assy  
Tiefziehbuchse, 90°, Assy  
Deep drawn socket, Pin 90 deg, Assy  
Tiefziehbuchse, Pin 90°, Assy  
2. Lock IL  
2. Kontaksicherung Interlock  
HVIL-Contacts, Tab contact 1.2mm Order-No: 1418760  
HVIL-Kontakte, Flachstecker 1.2mm Bestell-Nr.: 1418760  
7 of 27  
Rev H  
108-94268  
Interface drawings  
Schnittstellenzeichnungen  
Interface aggregate cut-out for 2/3 pos. HV-CAT-2 90° Pin housing  
Schnittstelle Aggregatausschnitt für 2/3-pol. HV-CAT-2 90°Stiftwanne  
114-94032  
114-94034  
114-94040  
Plug board pin dia 8mm, 2pos. / 3pos. HV, 90deg, 180deg  
Steckerleiste 8mm Rundpin, 2pol / 3pol HV, 90°, 180°  
Pin Dia 8mm  
Rundkontakt 8mm  
2.1.3 Specifications  
Spezifikationen  
Table 3: TE-Specifications  
Tabelle 3: TE-Spezifikationen  
Specification  
Spezifikation  
Description  
Beschreibung  
Qualification Test Report HVP800 2PHI AND 3PHI 90DEG, Pre-serial  
parts  
501-94004  
Qualifikationstestbericht HVP800 2phi und 3phi 90°, Kleinserienteile  
Product Specification HV 8MM 90DEG CONTACT  
Produktspezifikation HV 8mm 90 Grad Kontakt  
108-94256  
108-18782  
114-94052  
114-94083  
114-18464  
114-94153  
Product Specification MCON-1.2 Contact System  
Produktspezifikation MCON-1.2 Kontaktsystem  
Application Specification HVP800 2PHI AND 3PHI 90DEG  
Verarbeitungsspezifikation HVP800 2phi und 3phi 90°  
Application Specification HV 8MM 90DEG CONTACT  
Verarbeitungsspezifikation HV 8mm 90 Grad Kontakt  
Application Specifications MCON-1.2 Contact System  
Verarbeitungsspezifikation MCON-1.2 Kontaktsystem  
Application Specification HVP800 2PHI AND 3PHI PINHEADER  
Verarbeitungsspezifikation HVP800 2phi und 3phi Stiftleiste  
8 of 27  
Rev H  
108-94268  
2.2  
Other Documents  
Allgemeine Unterlagen  
Table 4: References  
Tabelle 4: Referenzen  
Document number  
Edition  
Standard: Title, Author  
Dokumentnummer  
Datum  
Norm: Titel, Autor  
DIN EN 60664-1  
DIN 40050-9  
ISO 20653  
2008-01  
1993-05  
2006-08  
2001-1  
Isolation coordination for equipment within low-  
voltage systems - Part 1: Principles, requirements  
and tests  
Isolationskoordinaten für elektrische Betriebsmittel in  
Niederspannungsanlagen Niederspannungsanlagen  
Teil 1: Grundsätze, Anforderungen und Prüfungen  
IP-Schutzarten, Degrees of protection  
(IP-Code) - Protection of electrical equipment  
against foreign objects, water and access  
IP- Schutzarten, Schutz gegen Fremdkörper, Wasser und  
Berühren Elektrischer  
Ausrüstung  
Road vehicles - Degrees of protection (IP-Code) -  
Protection of electrical equipment against foreign  
objects, water and access  
Straßenfahrzeuge, IP-Schutzarten, Schutz gegen  
Fremdkörper, Wasser und  
Berühren Elektrischer Ausrüstung  
ISO 6469-3  
ISO 16750  
Electric road vehicles Safety specifications. Part  
3: Protection of person against electric hazards  
Straßenfahrzeuge Sicherheitsspezifikation  
Teil 3: Schutz von Personen gegen elektrische Gefahren  
-1: 2006-01 Electric road vehicles Environmental conditions  
-2: 2010-03 and testing for electrical and electronic equipment  
-3: 2007-07 Straßenfahrzeuge Umgebungsbedingungen und  
-4: 2010-04 Prüfungen für elektrische und elektronische  
-5: 2010-04 Ausrüstungen,  
SAE J 1742  
1998-03  
(2005-12)  
Connections for High Voltage On-Board Road  
Vehicle, Electrical Wiring Harnesses Test Methods  
and General Performance Requirements  
LV 214-1  
LV 215-1  
2010-03  
2009-02  
Test specification for motor vehicle connectors  
AK Prüfrichtlinie für Kfz-Steckverbinder  
Electrical/Electronic Requirements of HV  
Connectors  
Elektrik / Elektronik Anforderungen an HV-  
Steckverbinder  
9 of 27  
Rev H  
108-94268  
3.  
REQUIREMENTS  
ANFORDERUNGEN  
3.1  
Design and Construction  
Entwurf und Konstruktion  
The product design, construction and physical dimensions shall correspondent to the latest customer  
drawings.  
Please note, prototype parts or pre-serial parts can be differing slightly in dimensioning, form- and  
position tolerances to the interface drawings.  
Das Produkt muss in seiner Ausführung und seinen physikalischen Abmessungen den letztgültigen  
Kundenzeichnungen entsprechen.  
Anmerkung, Prototypen- oder Vorserienteile können in geringfügigen Bereichen von den Maßen, Form- und  
Lagetoleranzen zu den Schnittstellenzeichnungen abweichen.  
3.2  
Material  
Werkstoff  
Descriptions for material see latest valid customer drawings.  
Angaben hierzu sind den letztgültigen Kundenzeichnungen zu entnehmen.  
3.3  
Ratings  
Leistungsmerkmale  
Table 5: Product Ratings  
Tabelle 5: Produktmerkmale  
Description  
Range  
Beschreibung  
Wert  
Max working voltage at 5500m above sea level  
≤ 650VDC  
Max. Betriebsspannung bei 5500m ü. NN  
Voltage class acc. ISO 6469-3  
B
Spannungsklasse nach ISO 6469-3  
Class 1 equipment acc. ISO 6469-3  
1
Ausrüstungsklasse nach ISO 6469-3  
Dielectric withstand voltage acc. ISO 6469-3, SAE J 1742  
Bemessungs-Stoßspannung nach ISO 6469-3, SAE J 1742  
2700V  
> 200MΩ  
Insulation resistance acc. ISO 6469-3, SAE J 1742  
Isolationswiderstand nach ISO 6469-3, SAE J 1742  
Isolation Group I and II acc. DIN EN 60664-1  
Isoliergruppe I und II snach DIN EN 60664-1  
600 ≤ CTI-components  
with direct contact to  
HV  
400≤CTI≤600  
Pollution degree acc. DIN EN 60664-1  
2
Verschmutzungsgrad nach DIN EN 60664-1  
10 of 27  
Rev H  
108-94268  
Description  
Range  
Beschreibung  
Wert  
Ambient temperature  
Umgebungstemperatur  
-40°C to 140°C  
IPXXB, IPXXD  
IP6K9K, IP6K7  
Degrees of protection (IP-Code) against access acc. ISO 20653  
Schutzgrade gegen Berühren gefährlicher Teile nach ISO 20653  
Degree of protection (IP-Code) against foreign objects and water  
acc. ISO 20653  
Schutzgrade gegen Eindringen fester Fremdkörper und Wasser nach  
ISO 20653  
Color of plastic cover  
Orange  
Farbe der Kunststoffgehäuse  
similar RAL 2003  
Orange ähnlich  
RAL 2003  
3.4  
Performance and Test Description  
Leistung und Testdurchführung  
The product is designed to meet the electrical, mechanical and environmental performance  
requirements specified in table 6. Unless otherwise specified, all tests shall be performed at ambient  
environmental conditions according to TE-TEC 109-1.  
Das Produkt erfüllt die in Tabelle 6 aufgeführten elektrischen, mechanischen und klimatischen Anforderungen.  
Falls nicht näher spezifiziert sind alle Prüfungen bei Raumtemperatur entsprechend der TE-TEC 109-1 Richtlinie  
durchgeführt.  
11 of 27  
Rev H  
108-94268  
3.5  
Test Requirements and Procedures Summary  
Testanforderungen und Testergebnisse  
Not shown test-details see LV214 / March 2010.  
Nicht angegebene Einzelheiten der Prüfungen siehe LV214 / März 2010.  
Table 6: Test Requirements and procedures Summary  
Tabelle 6: Testanforderung und Ergebnisse  
Test Description  
Requirement  
Procedure  
Testbeschreibung  
Anforderung  
Verfahren  
PG 0  
RECEIVING INSPECTION EINGANGSPRÜFUNG  
E 0.1  
Basic function proven  
LV215-2  
Visual inspection  
Sichtprüfung  
Grundfunktion gegeben  
DIN EN 60512-1-1  
E 0.2  
● Contact ≤0.36mΩ (50mm²); ≤0.39mΩ  
(35mm²)²); ≤0.40mΩ (25mm²)  
Kontakt ≤0.36mΩ (50mm²); ≤0.39mΩ (35mm²);  
≤0.40mΩ (25mm²)  
LV215-2  
DIN EN 60512-2-1  
Contact resistance  
Durchgangswiderstand  
● HVIL-contact ≤15mΩ  
HVIL-Kontakt 15mΩ  
● Shielding cable – Header < 7mΩ  
Schirmung Leitung - Stiftleiste < 7mΩ  
E 0.3  
● Insulation resistance at 1kVDC: >200MΩ  
LV215-2  
Insulation resistance  
Isolationswiderstand  
Isolationswiderstand bei 1kVDC: >200MΩ  
DIN EN 60512-3-1  
PG 4  
CONTACT OVERLAPPING KONTAKTÜBERDECKUNG  
E 4.1  
Values see appendix 5.3  
Theoretical study  
Contact engagement length  
Werte siehe Anhang 5.3  
Theoretische Studie  
Kontaktüberdeckung  
PG 6  
INTERACTION BETWEEN CONTACT AND HOUSING  
WECHSELWIRKUNG ZWISCHEN KONTAKT UND GEHÄUSE  
E 6.1  
● No damage during joining  
Theoretical study  
Deflection of contacts in the  
Keine Möglichkeit der Schädigung beim Fügen  
Theoretische Studie  
housing cavity  
Taumelspiele der Kontakte in  
der Gehäusekammer  
12 of 27  
Rev H  
108-94268  
B6.1  
Drop test  
Falltest  
● Drop test from 1m height; No damages or  
impairments of function  
Falltest aus 1m Höhe; Keine Beschädigungen,  
die die Gebrauchstauglichkeit beeinflussen  
LV215-2  
DIN EN 60068-2-31  
PG 7  
HANDLING AND FUNCTIONAL RELIABILITY OF THE HOUSINGS  
HANDHABUNG UND FUNKTIONSSICHERHEIT DER GEHÄUSE  
E 7.1  
● Coding/Polarisation Test load: >120N  
LV214  
Error-proof design of  
housings  
Kodierung/Polarisierung Prüfkraft: >120N  
DIN EN 60512-13-5  
Unverwechselbarkeit der  
Gehäuse  
E 7.2  
● Retention force of the housing catch  
mechanism / housing interlock: >250N  
Haltekraft der Gehäuseverrastung /  
Gehäuseverriegelung: >250N  
LV215-2  
DIN EN 60512-15-6  
Retention force of the  
housing latch/lock  
Haltekraft der  
Gehäuseverrastung /  
Gehäuseverriegelung  
E 7.3  
● Actuation force activating: 5 - 30N  
Betätigungskraft Aktivieren: 5 - 30N  
● Actuation force opening: 5 - 30N  
Betätigungskraft Öffnen: 5 - 30N  
● CPA Efficiency: >80N  
LV214  
LV214  
Functionality of CPA  
Funktion der CPA  
CPA-Effizienz: >80N  
E 7.4  
Insertion and actuation force: ≤ 75N  
Insertion force or actuation  
force for insertion with  
removal aids  
Steck- und Betätigungskraft: ≤ 75N  
Steckkraft bzw.  
Betätigungskraft bei Steck-  
und Ziehhilfen  
PG 8  
MATING AND RETENTION FORCE OF CONTACT PARTS  
EINSTECK- UND HALTEKRÄFTE DER KONTAKTTEILE  
LV214  
LV214  
E 8.1  
8mm-contact: Insertion force Average ≤ 50N  
8mm-Kontakt: Einsteckkraft Durchschnitt 50N  
Contact insertion forces  
Kontakteinsteckkräfte  
Primary lock and Secondary lock measured  
separately  
Primär- und Sekundärverriegelung getrennt  
gemessen  
E 8.2  
Contact removal force from  
the housing  
Kontaktausreißkraft aus dem  
Gehäuse  
Cable assy with 8mm-contact  
Kabel-Assy mit 8mm-Kontakt  
≥ 180N  
HVIL-contact HVIL-Kontakt  
≥ 55N  
13 of 27  
Rev H  
108-94268  
PG 9  
SKEWED INSERTION ANGLE SCHRÄGSTECKWINKEL  
E 9.2  
Max. possible insertion inclination warrants  
the contacting without damage  
Max. möglicher Schrägsteckwinkel garantiert die  
Kontaktpaarung ohne Schädigung  
Theoretical study  
Theoretische Studie  
Max. possible insertion  
inclination  
Max. möglicher  
Schrägsteckwinkel  
E 9.3  
Live parts must only touch its counter-part  
while mounting (including insertion  
chamfers). In case of incorrect insertion of  
the plug no live parts must be touched.  
Signal- und stromführende Bauteile dürfen bei  
Montage nur mit Ihrem Gegenstück berührt  
werden können. Auch bei fehlerhaftem  
Einstecken dürfen Kontakte nicht berührt  
werden.  
Theoretical study  
Theoretische Studie  
Koshiri Safety  
Überprüfung Gehäuse auf  
Koshiri-Sicherheit  
PG 11  
MATING CYCLES STECKHÄUFIGKEIT  
LV214  
B 11.1  
● Connector with HVIL-Contacts 50 Cycles  
Mating cycles  
Steckhäufigkeit  
Stecker mit Interlockkontakten 50 Zyklen  
PG 13  
DERATING GEHÄUSEEINFLUSS AUF DIE STROMERWÄRMUNG  
LV215-2  
DIN EN 60512-5-1/2  
E 13.2  
Derating with housing  
Derating im Gehäuse  
● Dependent on application and cable type  
different values are possible  
Abhängig von Anwendung, Ausführung und  
Leitungstyp können sich verschiedene Werte  
ergeben  
● Max. temperature at contacts 180°C  
Grenztemperatur Kontakte 180°C  
● Derating see appendix 5.1  
Werte siehe Anhang 5.1  
PG 17  
DYNAMIC LOAD DYNAMISCHE BEANSPRUCHUNG  
B 17.2  
● Severity 2: “Body” sealed; Details see  
appendix 5.2  
Schärfegrad 2: „Karosserie“ gedichtet; Details  
LV214  
DIN EN 60068-2-64  
Dynamic Load; broad-band  
random  
Dynamische Beanspruchung:  
Breitbandrauschen  
siehe Anhang 5.2  
● Slight wear, surface ok.  
Leichte Abnutzung, Oberfläche i.O.  
● Resistances after testing  
Durchgangswiderstand nach Test:  
● Contact Kontakt  
≤0.72mΩ  
14 of 27  
Rev H  
108-94268  
● HVIL-contact HVIL-Kontakt ≤15mΩ  
● Shielding cable - aggregate < 7mΩ  
Schirmung Leitung - Aggregat < 7mΩ  
B 17.3  
Endurance shock test  
Dauerschocken  
● 30g; T=6ms; N=6000  
LV214  
DIN EN 60068-2-27  
● Slight wear, surface ok.  
Leichte Abnutzung, Oberfläche i.O.  
● Resistances after testing  
Durchgangswiderstand nach Test:  
● Contact Kontakt  
≤0.72mΩ  
● HVIL-contact HVIL-Kontakt ≤15mΩ  
● Shielding cable - aggregate < 7mΩ  
Schirmung Leitung - Aggregat < 7mΩ  
In the event of particularly critical installation conditions, special agreements shall be made  
between the manufacturer and the user.  
Bei besonders kritischen Einbaubedingungen sind gesonderte Vereinbarungen zwischen Hersteller und  
Anwender zu treffen.  
PG18C  
DICING SALT LOAD STREUZSALZ-BEANSPRUCHUNG  
B 18.3  
● Resistances after Salt spray test, not sealed LV215-2  
Salt spray, cyclic  
Salznebel, zyklisch  
Durchgangswiderstände nach Salznebeltest,  
ungedichtet:  
DIN EN 60068-2-52  
(SG3)  
● Contact Kontakt  
≤0.72mΩ  
● HVIL-contact HVIL-Kontakt ≤15mΩ  
● Shielding cable - aggregate < 7mΩ  
Schirmung Leitung - Aggregat < 7mΩ  
PG20  
CLIMATIC LOAD OF HOUSINGS  
KLIMATISCHE BEANSPRUCHUNG DER GEHÄUSE  
B 20.1  
Dry heat  
Trockene Wärme  
● Dry heat 120h / 140°C  
Trockene Wärme 120h / 140°C  
LV214  
LV214  
B 20.2  
Damp heat  
Feuchte Wärme  
● Damp heat 10 days / 40°C / 95% rel.  
humidity  
Feuchte Wärme 10 Tage / 40°C / 95% Luftf.  
● Insulation resistance at 1kVDC: >200MΩ  
Isolationswiderstand bei 1kVDC: >200MΩ  
B 20.3  
Climatic cold  
Kältelagerung  
● Climatic cold 48h / -40°C  
Kältelagerung 48h / -40°C  
● Plugging / unmating possible at -20°C  
Stecken / Ziehen bei -20°C möglich  
LV214  
LV214  
B 20.1  
● Dry heat 48h / 80°C  
Dry heat  
Trockene Wärme 48h / 80°C  
Trockene Wärme  
15 of 27  
Rev H  
108-94268  
B6.1  
● Drop test from 1m height; No damages or  
impairments of function  
Falltest aus 1m Höhe; Keine Beschädigungen,  
die die Gebrauchstauglichkeit beeinflussen  
LV215-2  
DIN EN 60068-2-31  
Drop test after aging  
Falltest nach Alterung  
PG21  
LONG-TERM AGING LANGZEITTEMPERATURLAGERUNG  
B 21.1  
● 1000h at 140°C; Resistances after aging:  
LV215-2  
Long-term aging in dry heat  
1000h bei 140°C; Durchgangswiderstände nach  
DIN EN 60068-2-2  
Langzeitlagerung bei trockener Alterung:  
Wärme  
● Contact Kontakt  
≤0.72mΩ  
● HVIL-contact HVIL-Kontakt ≤15mΩ  
● Shielding cable - aggregate < 7mΩ  
Schirmung Leitung - Aggregat < 7mΩ  
● Functionality; Contact Removal forces acc.  
E8.2  
Funktionalität; Kontaktausreißkräfte nach E8.2  
PG22B  
CHEMICAL RESISTANCE CHEMISCHE BESTÄNDIGKEIT  
B 22.1B  
● Application of media for 48h at specified  
LV214  
Chemical Resistance (water- temperature; only tested at single parts  
tight design)  
Chemische Beständigkeit  
(gedichtete Ausführung)  
Beaufschlagung für 48h bei spezifizierter  
Temperatur; getestet an Einzelteilen  
● No textural or dimensional change, no  
impairments of function  
Keine strukturelle oder dimensionelle Verän-  
derung, keine Beeinträchtigung der Funktion.  
● Insulation resistance >100MΩ  
Isolationswiderstand >100MΩ  
PG23  
WATERTIGHTNESS WASSERDICHTHEIT  
B 19.3  
120h at 140°C  
120h bei 140°C  
DIN EN 60068-2-2  
DIN EN 60068-2-14  
Aging in dry heat  
Lagerung bei trockener Wärme  
B 19.1  
Temperature shock  
● Period: 144cycles -40°C / +140°C each  
15min  
Temperaturschock  
Dauer: 144 Zyklen -40°C / +140°C, je 15min  
B 23.1  
● Low pressure:  
LV214  
Immersion with pressure  
difference  
Tauchen mit Druckdifferenz  
-100mbar, holding time 5min.  
-500mbar, holding time 5min.  
Unterdruck:  
DIN EN 60512-14-5  
-100mbar, Haltezeit 5min.  
-500mbar, Haltezeit 5min.  
16 of 27  
Rev H  
108-94268  
B 23.2  
● Movement of cable at low pressure:  
-100mbar, holding time 5min.  
-500mbar, holding time 5min.  
Leitungsbewegung bei Unterdruck:  
-100mbar, Haltezeit 5min.  
LV214  
DIN EN 60512-14-5  
Immersion with pressure  
difference  
Leitungsbewegung bei  
Tauchen mit Druckdifferenz  
-500mbar, Haltezeit 5min.  
B 23.3  
Thermal shock test  
Thermoschockprüfung  
● 30min. in 120°C air; 15min in 0°C Water  
5 cycles  
30min in 120°C Luft; 15min. in 0°C Wasser  
Zyklenzahl: 5  
LV214  
B 23.4  
● Severity: IP X9K  
LV214  
Degree of protection  
test/pressure washer test  
Schutzartprüfung /  
Dampfstrahlprüfung  
Schärfegrad IP X9K  
DIN 40050-9  
● Test duration per side: 15s  
Distance to nozzle: 10 - 15 cm  
Pressure: 80 bar  
Temperature: 80°C  
Prüfdauer je Seite: 15s  
Abstand zur Düse: 10 15cm  
Druck: 80bar  
Temperatur: 80°C  
E 0.3  
● Insulation resistance at 500VDC: >100MΩ  
LV215-2  
Insulation resistance  
Isolationswiderstand  
Isolationswiderstand bei 500VDC: >100MΩ  
DIN EN 60512-3-1  
PG28  
LOCKING NOISE VERRIEGELUNGSGERÄUSCH  
LV214  
E 28.1  
● Locking noise ≥70dB(A)  
Locking Noise  
Verriegelungsgeräusch  
Verriegelungsgeräusch 70dB(A)  
PG50  
EMC- ELECTROMAGNETIC COMPATIBILITY EMV-PRÜFUNG  
PG50  
VG 95214-11  
LV215-1  
LV215-2  
Frequency Delta-Transferimpedance  
EMC- Electromagnetic  
compatibility  
Frequenz  
Delta-Transferimpedanz  
DC  
<2mΩ  
EMV- Elektromagnetische  
Verträglichkeit  
2MHz  
30MHz  
<10mΩ  
<60mΩ  
PG51  
IP PROTECTION OPEN CONNECTOR BERÜHRSCHUTZ  
PG51  
IP-protection IPXXB, un-mated  
ISO 20653  
Protection open connector  
Schutz vor Berührung; nicht  
gesteckt  
(VDE test finger Ø12mm)  
IP-protection IPXXD, mated  
IP-Schutzgrad IPXXB, ungesteckt  
VDE-Testfinger Ø12mm)  
IP-Schutzgrad IPXXD, gesteckt  
17 of 27  
Rev H  
108-94268  
3.6  
Additional Test Procedures and Test Results  
Zusätzliche Testdurchführungen und Testergebnisse  
Table 7: Additional test requirements  
Tabelle 7: Zusätzliche Testanforderungen  
Test Description  
Requirement  
Procedure  
Testbeschreibung  
Anforderung  
Verfahren  
A1  
● Pull-out force isolation crimp: 140N  
Ausreißkraft Isolationscrimp: 140N  
● Pull out force shield crimp: 280N  
Ausreißkraft Schirmcrimp: 280N  
● Cross section examination: crimp  
sleeves are well formed  
TE-Spec. 109-18212  
TE-Spec. 109-18212  
Crimp validation  
Crimpvalidierung  
Schliffbild: Verformung der Crimphülse in  
Ordnung  
A2  
● Protection cover for single wire seal:  
500N  
Schutzkappe für Einzeladerdichtung:  
500N  
Compression limiter (header): 50N  
Schraubbuchse (Stiftwanne): 50N  
● Finger protection cap (2141222): 120N  
Fingerschutz (2141222): 120N  
● Shielding sleeve (2141225): >100N  
Schirmblech (2141225): >100N  
DIN IEC 60512-8  
DIN IEC 60512-8  
Retention force further  
connector parts  
Haltekraft sonstiger  
Gehäuseteile  
A3  
● Insertion force Protection cover for  
single wire seal: <50N  
DIN IEC 60512-8  
DIN IEC 60512-8  
Insertion force further connector  
parts  
Einsteckkraft Schutzkappe für  
Einzeladerdichtung: <50N  
● Finger protection cap (2141159): <50N  
Fingerschutzkappe (2141159): <50N  
● Pinheader to aggregate: xxN  
Stiftleiste in Aggregat: xxN  
Einsteckkraft sonstiger  
Gehäuseteile  
A7  
● Measurement voltage: 1000VDC  
Messspannung: 1000VDC  
● Temperature load -40°C till 140°C  
Temperaturbeanspruchung -40°C bis  
140°C  
Insulation resistance  
with temperature load  
Isolationswiderstand  
bei Temperaturbelastung  
● Time: 60s  
Zeit: 60s  
● With rising temperature the insulation  
resistance fall down after temperature  
load the insulation resistance rising  
again.  
Mit zunehmender Temperatur nimmt der  
Isolationswiderstand ab und steigt mit  
zunehmender Entlastung wieder an.  
Insulation resistance  
Isolationswiderstand  
20°C  
140°C  
18 of 27  
Rev H  
108-94268  
Pinheader  
unmated  
Stiftleiste  
> 1TΩ  
225MΩ  
nicht gesteckt  
Plughousing  
unmated  
Buchsengeh.  
Nicht gesteckt  
Assembly  
> 1TΩ  
> 1TΩ  
121MΩ  
43MΩ  
Zusammenbau  
4.  
QUALITY ASSURANCE PROVISIONS  
QUALITÄTSSICHERUNGSMASSNAHMEN  
4.1  
Qualification Testing  
Qualifikationsprüfung  
The samples shall be prepared in accordance with product drawings and shall be selected at random  
from current production.  
Die Prüflinge müssen den Zeichnungsunterlagen entsprechen. Sie sind der laufenden  
Produktion zufällig zu entnehmen.  
19 of 27  
Rev H  
108-94268  
4.2  
Requalification Testing  
Requalifikationsprüfung  
If changes significantly affecting form, fit, or function depending on the product or manufacturing  
process, product engineering shall coordinate requalification testing, consisting of all or part of the  
original testing sequence as determined by development/product, quality, and reliability engineering.  
Falls signifikante Eigenschaftsänderungen der Form, Ausstattung oder Funktion des Produktes, sowie dessen  
Herstellungsverfahrens vorgenommen werden, muss ein entsprechender Requalifikationstest durchgeführt  
werden.  
Dieser kann je nach Festlegung der Entwicklungs- und Qualitätssicherungsabteilung aus einem Teil oder den  
gesamten ursprünglichen Prüfgruppen bestehen.  
4.2.1 Acceptance  
Abnahme  
Acceptance is based on verification that the product meets the requirements of chapter 4. Failures  
attributed to equipment, test setup, or operator deficiencies shall not disqualify the product. When  
product failure occurs, corrective action shall be taken and samples resubmitted for qualification.  
Testing to confirm corrective action is required before resubmittal.  
Die Abnahme basiert auf dem Nachweis, dass das Produkt den Anforderungen nach Kapitel 4 genügt.  
Abweichungen, die auf Messgeräte, Messanordnungen oder Bedienungsmängel zurückzuführen sind, dürfen nicht  
zum Entzug der Qualifikation führen. Tritt eine Abweichung auf, müssen korrigierend Maßnahmen ergriffen werden  
und die Qualifikation ist erneut nachzuweisen. Vor dieser Requalifikation ist durch entsprechende Prüfungen der  
Erfolg der Korrekturmaßnahme zu bestätigen.  
4.2.2 Quality Conformance Inspection  
Prüfung der Qualitätskonformität  
The applicable quality inspection plan will specify the sampling acceptable quality level to be used.  
Dimensional and functional requirements shall be in accordance with the applicable product drawing  
and this specification.  
Die Konformitätsprüfung erfolgt nach dem zugehörigen Qualitätsinspektionsplan, der die annehmbare  
Qualitätsgrenzlage nach dem Stichprobenumfang festlegt. Maßliche und funktionelle Anforderungen müssen mit  
den Produktzeichnungen und dieser Spezifikation übereinstimmen.  
20 of 27  
Rev H  
108-94268  
5.  
APPENDIX  
ANHANG  
5.1  
Housing influence on derating: 2pos connector  
Gehäuseeinfluss auf das Derating: 2pol-Steckverbinder  
Derating inside housing: Current at contact with load at shield  
Derating im Gehäuse: Kontaktbestromung mit Schirmbelastung  
80% Characteristic curve of measured value, cable length according to DIN EN 60512-5-2  
80% Kennlinie der gemessenen Werte mit Leitungslänge nach DIN EN 60512-5-2  
Figure 1: Derating and temperature rise 2pos 25mm² Coroplast-Part-No. 9-2611  
Abbildung 1: Derating und Stromerwärmung 2pol 25mm² Coroplast-Nr. 9-2611  
Figure 2: Derating and temperature rise 2pos 35mm² Coroplast-Part-No. 9-2611  
Abbildung 2: Derating und Stromerwärmung 2pol 35mm² Coroplast-Nr. 9-2611  
21 of 27  
Rev H  
108-94268  
Figure 3: Derating and temperature rise 2pos 50mm² Coroplast-Part-No. 9-2611  
Abbildung 3: Derating und Stromerwärmung 2pol 50mm² Coroplast-Nr. 9-2611  
Figure 4: Derating and temperature rise 2pos 35mm² kromberg & Schubert -  
Abbildung 4: Derating und Stromerwärmung 2pol 35mm² kromberg & Schubert  
5.2  
Housing influence on derating: 3pos connector  
Gehäuseeinfluss auf das Derating: 3pol-Steckverbinder  
Derating inside housing: Current at contact with load at shield  
Derating im Gehäuse: Kontaktbestromung mit Schirmbelastung  
80% Characteristic curve of measured value, cable length according to DIN EN 60512-5-2  
80% Kennlinie der gemessenen Werte mit Leitungslänge nach DIN EN 60512-5-2  
22 of 27  
Rev H  
108-94268  
Figure 5: Derating and temperature rise 3pos 25mm² Coroplast-Part-No. 9-2611  
Abbildung 5: Derating und Stromerwärmung 3pol 25mm² Coroplast-Nr. 9-2611  
Figure 6: Derating and temperature rise 3pos 35mm² Coroplast-Part-No. 9-2611  
Abbildung 6: Derating und Stromerwärmung 3pol 35mm² Coroplast-Nr. 9-2611  
23 of 27  
Rev H  
108-94268  
Figure 7: Derating and temperature rise 3pos 50mm² Coroplast-Part-No. 9-2611  
Abbildung 7: Derating und Stromerwärmung 3pol 50mm² Coroplast-Nr. 9-2611  
5.3  
Dynamic load  
Dynamische Beanspruchung  
Dynamic load acc. LV214 (release 03.2010)  
Dynamische Beanspruchung gemäß LV 214 (Ausgabe 03.2010)  
Design of vibration device (see picture 7)  
Aufbau der Vibrationsvorrichtung (siehe Bild 7)  
2 and 3pos. connector  
2 und 3pol- Steckverbinder  
Coroplast 50mm² acc. to Coroplast-No.: 9-2611 / 50mm², Version A4  
Coroplast 50mm² nach Datenblatt-Nr.: 9-2611 / 50mm², Revision A4  
Cable fixed after Dimensioning  
A= 100mm  
Leitungsabfangung nach Maß  
A= 100mm  
24 of 27  
Rev H  
108-94268  
100 mm  
Figure 8: Vibration device (exemplary view at 2pos. connector)  
Abbildung 8: Vibrationsvorrichtung (exemplarische Darstellung mit 2 pol. Stecker)  
5.4  
Contact engagement length  
Kontaktüberdeckung  
A
B
Contact overlap power contact  
Kontaktüberdeckung Leistungskontakt  
1mm  
1mm  
1mm  
Contact overlap HVIL contact  
Kontaktüberdeckung HVIL Kontakt  
Interlock Disconnected advanced by pull-out process  
Voreilende Trennung des HVIL beim Ziehvorgang  
25 of 27  
Rev H  
108-94268  
Figure 9: Contact engagement length  
Abbildung 9: Kontaktüberdeckung  
26 of 27  
Rev H  
108-94268  
5.5  
Strain Relief  
Leitungsabfangung  
System is validated with strain relief at 100mm. Each application has to be evaluated independently  
with regards to the external influences on the system. Having strain relief, which moves with the  
connector body, close to the end of the connector will have a positive influence on the performance of  
the connector. Having strain relief further from the end of the connector or that moves independent of  
the connector body will have a negative influence on the performance of the connectors.  
Die Steckverbindung wurde mit einer Leitungsabfangung von 100mm validiert. Jede Applikation ist aufgrund ihrer  
individuellen Anforderungen gesondert zu beurteilen. Leitungsabfangungen nach größeren Längen als 100mm  
haben eine negative Auswirkung auf die Steckverbinder-Performance und entsprechend positive bei kürzeren  
Distanzen  
100mm  
Figure 10: Recommended requirement for strain reliefs  
Abbildung 10: Empfohlene Anforderungen Leitungsabfangung  
LTR  
REVISION RECORD  
Derating Curve added for Kromberg & Schubert  
DWN  
APP  
DATE  
H
Shashikumar  
Tomas S  
08Mar2021  
cable added  
Isolation Group Update  
G1  
G
F
Shashikumar  
Shashikumar  
Dinh Hung Vu  
Tomas S  
Tomas S  
K.Kioschis  
27Nov2019  
17May2019  
11AUG2019  
Update V0 Header  
Update with serial parts  
27 of 27  
Rev H  

相关型号:

114-94052

AMP High Current Connectors and Headers
TE

114-94083

AMP High Current Connectors and Headers
TE

114-94153

AMP High Current Connectors and Headers
TE

114-99-210-41-117

Dual-in-line sockets and headers Open frame / surface mount
PREDIP

114-99-304-41-117

Dual-in-line sockets and headers Open frame / surface mount
PREDIP

114-99-306-41-117

Dual-in-line sockets and headers Open frame / surface mount
PREDIP

114-99-308-41-117

Dual-in-line sockets and headers Open frame / surface mount
PREDIP

114-99-310-41-117

Dual-in-line sockets and headers Open frame / surface mount
PREDIP

114-99-314-41-117

Dual-in-line sockets and headers Open frame / surface mount
PREDIP

114-99-316-41-117

Dual-in-line sockets and headers Open frame / surface mount
PREDIP

114-99-318-41-117

Dual-in-line sockets and headers Open frame / surface mount
PREDIP

114-99-320-41-117

Dual-in-line sockets and headers Open frame / surface mount
PREDIP