3EHGS1-2 [TE]
Smallest Filtered Power Entry Modules with Metric Fuseholders; 最小的滤波电源输入模块与公制保险丝盒型号: | 3EHGS1-2 |
厂家: | TE CONNECTIVITY |
描述: | Smallest Filtered Power Entry Modules with Metric Fuseholders |
文件: | 总2页 (文件大小:67K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
CORCOM Product Guide
Smallest Filtered Power Entry Modules with Metric Fuseholders
GG/HG Series
UL Recognized
CSA Certified
VDE Approved
HG1/GG1
GG8
GG Series
Specifications
Maximum leakage current,each line-to-ground
HG Models
The GG series power entry modules combine the functions
of a general purpose RFI filter with an IEC power cord
connector and single or dual metric fusing, in the smallest
possible panel space. A choice of .250” terminals or wire
leads is available for the load-side terminations.
GG Models
.25 mA
@ 120 VAC 60 Hz:
@ 250 VAC 50 Hz:
Hipot rating (one minute):
line-to-ground
2µA
5µA
.42 mA
For maximum cost effectiveness, 6 amp models should be
used for all applications rated 6 amps or less, unless the
higher performance of the 3 amp models, or the much
higher performance of the 1 amp models, is needed.
1550 VAC
1450 VDC
50/60 Hz
line-to-line
Operating frequency:
Rated voltage (max.):
Fuse (not included):
250 VAC
Models with C-suffix additionally incorporate a ground
choke1 to isolate the equipment chassis from external
ground at RF frequencies.
Accepts one 5x20mm fuse
(-1 models) or two 5 x 20 mm
fuses (-2 models)
HG Series
Minimum insertion loss in dB:
Line-to-ground in 50 ohm circuit
A medical version of our GG series, these filters offer the
same compact design but reduce the line-to-ground
capacitance in order to meet UL 2601 patient care
requirements. For more information on UL2601
specification, see Appendix C.
Current
Frequency-MHz
Rating .01 .05 .10 .15 .5
1
5
10 30
GG/GS Models
Note: When using the models with an IEC connector,
remember that the leakage current of the companion line
cord, GA400, is more significant than that of the filter -
which may disqualify this line cord from use in patient care
applications.
1A
3A
6A
12
–
–
23
10
1
29 32 41 47 50 50 55
15 19 30 36 48 50 53
10 16 22 36 40 50
4
HG Models
1A
3A
6A
12
–
–
23
10
4
29 32 40 40 28 22 18
15 19 25 26 22 21 21
10 14 18 18 14 14 14
Electrical Schematics
GG/GS/HG
Note 1
LINE
LOAD
Line-to-line in 50 ohm circuit
Current
Rating
Frequency-MHz
.01 .15 .5
1
3
5
10 30
Note 2
GG/GS Models
GG-C
1A
3A
6A
1
1
1
3
2
2
14 23 41 47 50 44
11 14 25 38 44 40
10 13 23 33 39 42
Note 1
LINE
LOAD
HG Models
1A
3A
6A
1
1
1
3
2
2
26 35 35 35 27 20
30 30 30 30 30 30
30 30 30 30 30 30
Note 2
Resistor location for reference only.
Note 1: Depicts single fuse for -1 models.
Note 2: For HG delete line-to-ground capacitors.
CAUTION: DO NOT ATTEMPT TO OPERATE A SINGLE-FUSED MODEL WITHOUT THE
FUSE DOOR IN PLACE!
112
Catalog 1654001
Revised 05-07
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
www.corcom.com
www.tycoelectronics.com
Germany:
49-89-6089-0
CORCOM Product Guide
Smallest Filtered Power Entry Modules with Metric Fuseholders (Continued)
GG/HG Series
EGS
Case Styles
GG1/HG1
C
D
C
E
B
A
D
E
B
A
Recommended Panel Cutouts
GG / HG
GS / HGS
Front or Back Mount
Front Mount Only
1.14
1.24
29.0
31.5
Typical dimensions:
Terminals: .250 [6.35] (3)
Holes: .07 [1.8] Dia.
Mounting Holes: .126 [3.20] Dia. (2)
1.30
33.0
1.29
32.8
for panel thickness
.032-.080
GG8
[.81-2.03]
Radius: 0.138
[0.35]
1.417
36.0
Blue
Green/Yellow
Brown
Case Dimensions
A
B
C
D
E
± .015
B
Part No.
(max) (max) (max)
(max)
± .38
EGG1-1/EGG1-2/
EHG1-2
EGG8-1/EGG8-2
EGG8C-1/EGG8C-2
EGS1-1/EGS1-2
EHGS1-2
2.15 1.13 1.29 1.417 1.76
54.5 28.7 32.8 36.0 44.7
2.02 1.13 1.29 1.417 1.76
51.1 28.7 32.8 36.0 44.7
2.13 1.13 1.28 1.46* 1.42
54.0 28.7 32.5 36.0 36.1
C
.6
15.2
D
E
A
EGG1C-1-1/EGG1C-2 2.45 1.13 1.28 1.46* 1.42
62.23 28.7 32.5 36.0 36.1
Typical dimensions:
Wire leads: 5.0 [127.0] Min. 18 AWG Mounting Holes: .126 [3.20] Dia. (2)
*max
Part Number1
1EGG1-1
1EGG1-2
1EGG8-1
1EGG8-2
1EGS1-1
1EGS1-2
3EGG1-1
3EGG1-2
3EGG8-1
3EGG8-2
3EGS1-1
3EGS1-2
6EGG1-1
6EGG1-2
6EGG8-1
6EGG8-2
6EGS1-1
6EGS1-2
1EHG1-2
3EHG1-2
6EHG1-2
1EHGS1-2
3EHGS1-2
6EHGS1-2
RFI Filter Type2
General Purpose2
General Purpose
General Purpose
General Purpose
General Purpose
General Purpose
General Purpose
General Purpose
General Purpose
General Purpose
General Purpose
General Purpose
General Purpose
General Purpose
General Purpose
General Purpose
General Purpose
General Purpose
Medical
Current Rating
Metric Fuseholders
Load Side Terminations
.250 [6.35] Terminals (3)
.250 [6.35] Terminals (3)
5.0 [127.0] Wire Leads
5.0 [127.0] Wire Leads
.250 [6.35] Terminals (3)
.250 [6.35] Terminals (3)
.250 [6.35] Terminals (3)
.250 [6.35] Terminals (3)
5.0 [127.0] Wire Leads
5.0 [127.0] Wire Leads
.250 [6.35] Terminals (3)
.250 [6.35] Terminals (3)
.250 [6.35] Terminals (3)
.250 [6.35] Terminals (3)
5.0 [127.0] Wire Leads
5.0 [127.0] Wire Leads
.250 [6.35] Terminals (3)
.250 [6.35] Terminals (3)
.250 [6.35] Terminals (3)
.250 [6.35] Terminals (3)
.250 [6.35] Terminals (3)
.250 [6.35] Terminals (3)
.250 [6.35] Terminals (3)
.250 [6.35] Terminals (3)
3
1
1
1
1
1
1
3
3
3
3
3
3
6
6
6
6
6
6
1
3
6
1
3
6
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
2
2
2
2
2
2
Medical
Medical
Medical
Medical
Medical
1
2
Ground choke available on general purpose models. Add suffix "C" (1EGG1C-1). Does not include EGS models.
3
General purpose filter for susceptibility applications.
Current rating @120 VAC and 250 VAC.
113
Catalog 1654001
Revised 05-07
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
Germany: 49-89-6089-0
www.corcom.com
www.tycoelectronics.com
相关型号: