6VN1_11 [TE]
High Performance RFI Filters for Switching Power Supplies; 高性能RFI滤波器,用于开关电源型号: | 6VN1_11 |
厂家: | TE CONNECTIVITY |
描述: | High Performance RFI Filters for Switching Power Supplies |
文件: | 总2页 (文件大小:146K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
High Performance RFI Filters for Switching Power Supplies
N Series
UL Recognized
CSA Certified
VDE Approved
6VN1
10VN1
N Series
Specifications
• Superior attenuation for most digital electronic
equipment over the frequency range of 10kHz to
30MHz
Maximum leakage current each Line to Ground:
@ 120 VAC 60 Hz:
@250 VAC 50 Hz:
1.2 mA
2.0 mA
Hipot rating (one minute):
Line to Ground:
• Provides excellent common mode and differential
mode performance
2250 VDC
1450 VDC
Line to Line:
• Cost-effective solution to very noisy equipment
that must meet conducted emission limits
Rated Voltage (max):
250 VAC
50/60 Hz
6 to 10A
Operating Frequency:
Rated Current:
Operating Ambient Temperature Range
(at rated current I ):
-10°C to +40°C
In an ambient temperature (T ) higher than +40°C
r
a
the maximum operating current (I ) is calculated as
o
follows: I = I (85-Ta)/45
o
r
Ordering Information
10 V N 1
Electrical Schematics
Input / Output Style
1 – .250 [6.3] spade terminals
3VN
N Series
LINE
LOAD
Leakage current designation
V – Standard
Current Rating
6 or 10A
10VN
Available Part Numbers
LINE
LOAD
6VN1
10VN1
56
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
High Performance RFI Filters for Switching Power Supplies (continued)
N Series
Case Styles
Performance Data
Typical Insertion Loss
Measured in closed 50 Ohm system
1
6VN
100
10VN
100
db
db
B
90
80
70
60
50
40
30
20
10
90
80
70
60
50
40
30
20
10
D
E
A
C
0
0
0.01
0.1
1
10
30
0.01
0.1
1
10
30
Frequency in MHz
Frequency in MHz
Common Mode / Asymmetrical (L-G)
Differential Mode / Symmetrical (L-L)
Case Dimensions
Minimum Insertion Loss
Measured in closed 50 Ohm system
A
Part No.
B
C
D
E
Common Mode / Asymmetrical (Line to Ground)
6VN1
10VN1
Differential Mode / Symmetrical (Line to Line)
57
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com