Features  
• Sealed, constructed of 16 gauge cold rolled steel  
• All non-conductive surfaces protected with suitable  
painting or electroplating  
6P16 †  
• Removable input cover for terminal access and field  
wiring connection  
• Threaded conduit fitting with flexible lead on the load  
side  
• Knockouts provided on the input side  
• Discharge bleeder resistor provided to reduce shock  
hazard  
• Surge protector provided upon request  
Electrical Characteristics  
Voltage Drop:  
Less than 1% @ unity power factor  
Overload:  
140% of rated current for 15 minutes  
Harmonic Distortion:  
Less than 2% @ full rated current  
Dielectric Withstanding Voltage:  
Per MIL-PRF-15733 and UL1283  
D.C. Insulation Resistance:  
Per MIL-STD-202, Method 302  
Terminal Strength:  
Per MIL-STD-202, Method 211, Condition E  
Temperature Rise:  
Per MIL-PRF-15733 and UL1283  
R.F. Radiation:  
100 dB minimum shielding effectiveness  
Insertion Loss:  
100 dB from 14 kHz - 10 GHz per MIL-STD-220A, under  
load condition  
Applicable Publications:  
How to Order:  
MIL-PRF-15733 — Filters, radio interference  
MIL-STD-202 Test methods for Components  
MIL-STD-220A Test method of Insertion Loss  
MIL-STD-285 Test method for Shielding Effectiveness  
NFPA 70-1987 — National Electric Code  
CDSUW 2 030 A6 - C - S  
Surge Arrestors (optional)1  
Conduit Fitting (supplied)  
Voltage/Frequency  
A6 - 120/208V, 60Hz  
B6 - 277/480V, 60Hz  
A4 - 120/208V, 400Hz  
486A - 1983 — Wire Connectors and Lug  
UL1283 — Underwriter Laboratories  
Current Rating 2  
# of Filters  
Series  
Examples: CDSUW2030A6-C-S, CDSUW1010B6-C  
Note 1:  
Surge Arrestor for A6/A4* Models: V251BA60  
Surge Arrestor for B6 Models: V481BA60  
Note 2:  
Current configuration listed as 3 digits with leading zeros  
† 60 Hz Models Only  
18  
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric  
equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.  
USA Cust. Svc.:  
Corcom Prods:  
1-800-468-2023  
1-847-680-7400  
www.tycoelectronics.com  
www.corcom.com  
Catalog: 1654986  
Issue Date: 11.2009  
Corcom Facility EMI Filters Product Guide  
CDSUW-C Series  
(continued)  
A
F
Label  
B
E
2
Knockouts for  
0.75 (19.05) & 1.0 (ꢀ5.4)  
Conduit  
D
1/2 D  
3 Places  
C
2.0  
50.8  
1.0 (ꢀ5.4) NPT Supplied  
with RF Gasket,  
Flange Nut and  
Ground Stud  
& Lug  
14.0 1.0  
355.6 ꢀ5.4  
Insulating Bushing  
Insulated wire  
Type THHN  
Current  
(Amps)  
Dimensions  
Wire Gauge  
Approx. Weight  
(Pounds/KG)  
15  
CDSUW  
A
B
C
D
5.0  
127.0  
5.0  
127.0  
5.0  
127.0  
5.0  
127.0  
6.0  
152.4  
8.0  
203.2  
9.0  
E
3.0  
76.2  
5.5  
139.7  
4.0  
101.6  
9.0  
228.6 10.9 x 19.1  
5.5  
139.7  
5.5  
139.7  
9.0  
F
(AWG/mm2)  
.063 [1.6]  
21.0  
533.4  
21.0  
533.4  
26.0  
660.4  
26.0  
660.4  
32.0  
812.8  
34.0  
863.6  
41.0  
1041.4  
41.0  
.063 [1.6]  
.063 [1.6]  
4.0  
101.6  
8.0  
203.2  
6.0  
152.4  
12.0  
304.8  
8.0  
203.2  
8.0  
203.2  
10.0  
254.0  
10.0  
5.0  
127.0  
5.0  
127.0  
6.0  
152.4  
6.0  
152.4  
6.0  
152.4  
6.0  
152.4  
6.0  
152.4  
6.0  
.31 x .50  
7.87 x 12.7  
.43 x .75  
10.9 x 19.1  
.31 x .50  
7.87 x 12.7  
.43 x .75  
10  
5.26  
10  
5.26  
6
13.20  
6
13.20  
6
13.20  
2
33.6  
0
53.5  
250 MCM  
126.0  
1010**-C  
2010**-C  
1030**-C  
2030**-C  
1060**-C  
1100**-C  
1150**-C  
1225**-C  
10  
2 x 10  
30  
6.80  
30  
13.6  
30  
13.6  
60  
27.2  
60  
27.2  
70  
31.8  
90  
40.8  
120  
54.4  
2 x 30  
60  
.43 x .75  
10.9 x 19.1  
.43 X .75  
10.9 x 19.1  
.43 X .75  
100  
150  
228.6  
9.0  
228.6  
228.6 10.9 x 19.1  
9.0 .43 X .75  
228.6 10.9 x 19.1  
225  
1041.4  
254.0  
152.4  
Max. Operating Voltage  
A6:  
120/208V, 60 Hz  
277/480V, 60 Hz  
120/208V, 400 Hz  
B6:  
*400Hz filters available upon request. Will require external power factor correction coil.  
Please contact Tyco Electronics Application Engineering 847-573-6517.  
A4*:  
19  
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric  
equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.  
USA Cust. Svc.:  
Corcom Prods:  
1-800-468-2023  
1-847-680-7400  
www.tycoelectronics.com  
www.corcom.com  

相关型号:

CDSUW2010A6-C-S

CDSUW-C Series
TE

CDSUW2010B6-C-S

CDSUW-C Series
TE

CDSUW2030A4-C-S

CDSUW-C Series
TE

CDSUW2030A6-C-S

CDSUW-C Series
TE

CDSUW2030B6-C-S

CDSUW-C Series
TE

CDSUX-C

CDSUX-C Series - Extended Range Buffer Networks
TE

CDSUX-C_11

CDSUX-C Series - Extended Range Buffer Networks
TE

CDSUX1010A4-C

CDSUX-C Series - Extended Range Buffer Networks
TE

CDSUX1010A4-C-S

CDSUX-C Series - Extended Range Buffer Networks
TE

CDSUX1010A6-C

CDSUX-C Series - Extended Range Buffer Networks
TE

CDSUX1010A6-C-S

CDSUX-C Series - Extended Range Buffer Networks
TE

CDSUX1010B6-C

CDSUX-C Series - Extended Range Buffer Networks
TE