CNT-35-96 [TE]
CNT series Multifunction, Digital Time Delay Relay/Counter; CNT系列多功能数码延时继电器/计数器型号: | CNT-35-96 |
厂家: | TE CONNECTIVITY |
描述: | CNT series Multifunction, Digital Time Delay Relay/Counter |
文件: | 总2页 (文件大小:58K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Catalog 1308242
Issued 3-03
P&B
CNT series
Multifunction, Digital
Tim e Delay Relay/ Counter
• 10 programmable timing modes + 2 counting modes
• 0.1 sec. to 9,990 hr. programmable timing range
• 1 to 99,900 counting range
• LCD digital display
• Universal (24-240VAC/VDC) and fixed input types
• 10A output relay with DPDT contacts
• Thumbwheel switches for programming
File E22575
File LR15734
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that user also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Input Data @ 25°C
Tim ing and Counting Modes
Voltage: Universal Input Type: 24 - 240V ±15% , 50/60 Hz. AC or DC.
Fixed Input Types: 120VAC ±15% , 50/60 Hz and 12VDC.
Pow er Requirem ent:
See the follow ing page for a com plete description of all program -
m able tim ing and counting m odes.
Universal Input Type: 10VA @ 240VAC; 5VA @ 120VAC; 1VA @ 24VAC.
10W @ 240VDC; 5W @ 120VDC; 1W @ 24VDC.
Fixed Input Types: 3VA @ 120VAC; 3W @ 12VDC.
Transient Protection: Yes.
Tim ing Specifications
Tim ing Ranges: 0.1 to 99.9 / 1 to 999 sec.; 0.1 to 99.9 / 1 to 999 min.;
0.1 to 99.9 / 1 to 999 / 10 to 9,990 hr.
Tim ing Adjustm ent: Digital adjustment via thumbwheel switches.
Tolerance: ±0.5% ±0.05 sec.
Reverse Voltage Protection: Yes.
Delta Tim e (for AC units add ±1 cycle 60 Hz.): ±0.1% ±0.05 sec.
Repeatability (Including first cycle of operation.): ±0.1% ±0.05 sec.
Reset Tim e (pow er interruption): 45 ms, typ.; 60 ms, max.
Minim um Pulse Width, Control: 50 ms.
Input Voltages & Lim its @ 25°C
Input
Type
Nom inal
Voltage
Minim um
Voltage
Maxim um
Voltage
Recycle Tim e: 45 ms, typ.; 60 ms, max.
Universal
Fixed
24-240VAC/VDC
120VAC
20.4VAC/VDC
102VAC
276VAC/VDC
138VAC
Counting Specifications
12VDC
10.2VDC
13.8VDC
Maxim um Count: 1 to 999; 10 to 9,990 (÷10); 100 to 99,900 (÷100).
Maxim um Count Rate: 100 counts per second.
Mim um um Pulse Width:Count (Control): 3 ms.; Reset: 3 ms.
Available Counting Functions: Operate at preset count and release at
preset count.
Note: DC voltage must be filtered (5% p-p ripple max. at nom. voltage).
AC models will operate on 50 or 60 Hz.
Environm ental Data
Tem perature Range: Storage: -20°C to +70°C.
Operating: -10°C to +55°C.
Contact Data @ 25°C
Arrangem ents: 2 Form C (DPDT).
Hum idity: 85% relative humidity, non-condensing.
Material: Silver-cadmium oxide alloy.
Rating: 10A @ 30VDC or 277VAC, resistive; 1/2 HP @ 250VAC; 1/3 HP @
120VAC.
Mechanical Data
Term ination: 11-pin octal style plug.
Expected Mechanical Life: 10 million operations.
Expected Electrical Life: 100,000 operations, min., at rated load.
Enclosure: Beige plastic 1/16 DIN case.
Sockets: Fits either 27E123 or 27E892 (snap-on) screw terminal sockets.
Weight: 4.3 oz. (122g) approximately.
External Control: CONTROL, RESET: Active on contact closure or solid
state switch closure to RETURN, 0-1.0VDC maximum
voltage level (see wiring diagrams for interface circuits.
Initial Dielectric Strength
Betw een Open Contacts: 1,000V rms, 60 Hz.
Betw een All Other Conductors: 1,500V rms, 60Hz.
Ordering Inform ation – Authorized distributors are m ore likely to stock boldface item s listed below .
Accessories
Universal Input Model
Part Num ber
Nam e
Description
Input Voltage
Part Num ber
CNT-35-96
SSA-24C667 Mounting Clip
Ratchet-fit clip slides onto CNT from behind
to secure CNT in panel mount applications.
24-240VAC/VDC
Fixed Input Models
Input Voltage
SSA-24C668 Protective Cover Clear, flexible cover slips snugly over bezel of
CNT to help protect against dust and moisture.
Part Num ber
Durable cover also helps prevent inadvertant
changes of programming switch settings.
12VDC
120VAC
CNT-35-26
CNT-35-76
Outline Dim ensions
Wiring Diagram s (Bottom View s)
(pins num bered clockw ise from keyw ay)
1.88
(47.8)
2.83
(71.9)
EXTERNAL CONTROL SWITCHES**
RESET
CONTROL
RETURN
.32
(8.1)
CONTROL
(COUNT)
RETURN
RESET
O
NC
N
USE SAME
FOR RESET
1.88
(47.8)
1. 76
(44.7)
1
11
1
11
A
1
1
1
H
_
INPUT*
_
+
INPUT*
+
*
Note: Input polarity for DC operation. For most reliable operation on AC, connect high side
.64
(16.3)
to “+” and low side to “–”.
** Im portant: A dry circuit switch is recommended. A “dry circuit” switch is one rated to
reliably switch currents of less than 50mA. Use of a switch rated for other
than dry circuit may result in failure of the time delay relay to function properly.
Fits 1.77 x 1.77 (45 x 45)
Panel cutout
3.15
(80.0)
Dimensions are shown for
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
1211
Catalog 1308242
Issued 3-03
P&B
Protective Cover & Mounting Clip Dim ensions
SSA-24C668
Protective Cover
SSA-24C667
Mounting Clip
1.99
.40
(50.5)
(10.2)
“A
”
2.283
(58.0)
1.970
(50.0)
2.047
(52.0)
1.99
(50.5)
.591
(15.0)
1.654
(42.0)
Section "A-A"
“A
”
1.890
(48.0)
Program m ing Sw itch Diagram
With this setting, the relay would operate after a delay period of 214 seconds.
A
2
1
4
S
Function Select:
Tim er Mode:
A = Delay On Operate
B = Delay On Release
C = Interval On
E = Recycle
F = Single Cycle
G = Control On-Off Interval On
H = Control On-Off Delay
I = Pulse
J = Cumulative Delay On Operate
D = Control-Off Interval On
Counter Mode:
B = Divide by 10
C = Divide by 100
A & D-J = Normal Count
Tim e/Counter Setting: 001 to 999
Tim e Base/Counter Mode Select:
Tim e Base:
.1S = 0.1 to 99.9 Sec. .1M = 0.1 to 99.9 Min.
= 1 to 999 Sec. = 1 to 999 Min.
CR = Release at Preset Count
.1H = 0.1 to 99.9 Hrs.
H = 1 to 999 Hrs.
10H =10 to 9990 Hrs.
S
M
Counter Mode: CO = Operate at Preset Count
Tim er Function Descriptions
A . Delay On Operate
Output relay turned on at end of programmed time interval which is started
by CONTROL input or power-on with CONTROL on. Relay turned off by
RESET input until next cycle is started. With CONTROL on, turning RESET
off restarts timing
started by momentary CONTROL input or power-on with CONTROL
on. Relay stays on for equal time interval, then turns off. RESET
terminates timing and turns relay off. Turning RESET off does not restart
timing.
G. Control On-Off Interval On (Watch Dog Tim er)
B. Delay On Release
Output relay turned on and programmed time interval started or restarted
by change of CONTROL input. RESET turns relay off and stops timing.
Turning RESET off does not restart timing.
Output relay turned on with CONTROL input and remains on for programmed
time interval following removal of CONTROL. During time interval after
release of CONTROL, RESET turns relay off until cycle restarted with
reapplication of CONTROL. With CONTROL on, relay is held off while
RESET is activated.
H. Control On-Off Delay
Output relay turned on at end of programmed timing interval which is
started or restarted by change of CONTROL input. If relay is on, turn-off
of relay occurs at end of programmed time interval which is started or
restarted by change of CONTROL input. RESET turns relay off and stops
timing. Turning RESET off does not restart timing.
C. Interval On
Output relay turned on for programmed time interval by CONTROL or power-
on with CONTROL on. RESET turns relay off until next cycle is started, and
does not restart timing when RESET is removed.
I. Pulse
D. Control-Off Interval On
Output relay turned on at end of programmed time interval, which is
started by CONTROL input, for 0.5 second duration, and continues in
pulsed mode at programmed time interval with fixed 0.5 second on-time.
Turning CONTROL off turns relay off and stops timing. RESET turns relay
off and inhibits operation. With CONTROL on, removal of RESET restarts
timing.
Output relay turned on for programmed time interval by turn-off of CON-
TROL. RESET turns relay off until next cycle is started, and does not restart
timing when RESET is removed.
E. Recycle
Output relay turned on at end of programmed time interval which is started
by momentary CONTROL input or power-on with CONTROL on. Relay stays
on for equal time interval, then turns off and cycle is repeated on a free-
running basis until terminated by momentary RESET, turning relay off. With
CONTROL on, turning RESET off restarts cycle.
J . Cum ulative Delay On Operate
Output relay turned on at completion of total accumulate CONTROL input
duration equal to programmed time. Turning CONTROL off before
accumulation of programmed time results in measured time total being
held until CONTROL is again turned on and total programmed time value
is reached. RESET input resets time value to zero and turns relay off if
energized. Turning RESET off restarts timing if CONTROL is on.
F. Single Cycle
Output relay turned on at end of programmed time interval which is
Counter Function Descriptions
CO – Operate at Preset Count – Norm al Mode
CR – Release at Preset Count – Norm al Mode
Initializing by momentary activation of RESET input turns relay on. Operation
is similar to CO (Operate at Preset Count) except relay turns off at a preset
count.
After initializing by momentary activation of RESET input, each on/off signal
at COUNT (CONTROL) input increments displayed count in upcounting
manner from initial 000 value until preset count, set by thumbwheel
switches, is reached and output relay turns on. Additional inputs continue to
increment displayed count. Continued counting past maximum count (999)
results in a “wrap-around” effect to 000, followed by contrinued up-counting.
Activation of RESET input turns relay off and resets count to zero.
CO or CR – Divide-by-10 Mode
Operation is as described previously, except count is incremented for every
10 on/off input signals for a maximum presettable count of 9,990.
CO or CR – Divide-by-100 Mode
Operation is as described previously, except count is incremented for every
100 on/off input signals for a maximum presettable count of 99,900.
Dimensions are shown for
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
1212