CNT-35-96 [TE]

CNT series Multifunction, Digital Time Delay Relay/Counter; CNT系列多功能数码延时继电器/计数器
CNT-35-96
型号: CNT-35-96
厂家: TE CONNECTIVITY    TE CONNECTIVITY
描述:

CNT series Multifunction, Digital Time Delay Relay/Counter
CNT系列多功能数码延时继电器/计数器

计数器 延时继电器 光电二极管
文件: 总2页 (文件大小:58K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Catalog 1308242  
Issued 3-03  
P&B  
CNT series  
Multifunction, Digital  
Tim e Delay Relay/ Counter  
• 10 programmable timing modes + 2 counting modes  
• 0.1 sec. to 9,990 hr. programmable timing range  
• 1 to 99,900 counting range  
• LCD digital display  
• Universal (24-240VAC/VDC) and fixed input types  
• 10A output relay with DPDT contacts  
• Thumbwheel switches for programming  
File E22575  
File LR15734  
Users should thoroughly review the technical data before selecting a product part  
number. It is recommended that user also seek out the pertinent approvals files of  
the agencies/laboratories and review them to ensure the product meets the  
requirements for a given application.  
Input Data @ 25°C  
Tim ing and Counting Modes  
Voltage: Universal Input Type: 24 - 240V ±15% , 50/60 Hz. AC or DC.  
Fixed Input Types: 120VAC ±15% , 50/60 Hz and 12VDC.  
Pow er Requirem ent:  
See the follow ing page for a com plete description of all program -  
m able tim ing and counting m odes.  
Universal Input Type: 10VA @ 240VAC; 5VA @ 120VAC; 1VA @ 24VAC.  
10W @ 240VDC; 5W @ 120VDC; 1W @ 24VDC.  
Fixed Input Types: 3VA @ 120VAC; 3W @ 12VDC.  
Transient Protection: Yes.  
Tim ing Specifications  
Tim ing Ranges: 0.1 to 99.9 / 1 to 999 sec.; 0.1 to 99.9 / 1 to 999 min.;  
0.1 to 99.9 / 1 to 999 / 10 to 9,990 hr.  
Tim ing Adjustm ent: Digital adjustment via thumbwheel switches.  
Tolerance: ±0.5% ±0.05 sec.  
Reverse Voltage Protection: Yes.  
Delta Tim e (for AC units add ±1 cycle 60 Hz.): ±0.1% ±0.05 sec.  
Repeatability (Including first cycle of operation.): ±0.1% ±0.05 sec.  
Reset Tim e (pow er interruption): 45 ms, typ.; 60 ms, max.  
Minim um Pulse Width, Control: 50 ms.  
Input Voltages & Lim its @ 25°C  
Input  
Type  
Nom inal  
Voltage  
Minim um  
Voltage  
Maxim um  
Voltage  
Recycle Tim e: 45 ms, typ.; 60 ms, max.  
Universal  
Fixed  
24-240VAC/VDC  
120VAC  
20.4VAC/VDC  
102VAC  
276VAC/VDC  
138VAC  
Counting Specifications  
12VDC  
10.2VDC  
13.8VDC  
Maxim um Count: 1 to 999; 10 to 9,990 (÷10); 100 to 99,900 (÷100).  
Maxim um Count Rate: 100 counts per second.  
Mim um um Pulse Width:Count (Control): 3 ms.; Reset: 3 ms.  
Available Counting Functions: Operate at preset count and release at  
preset count.  
Note: DC voltage must be filtered (5% p-p ripple max. at nom. voltage).  
AC models will operate on 50 or 60 Hz.  
Environm ental Data  
Tem perature Range: Storage: -20°C to +70°C.  
Operating: -10°C to +55°C.  
Contact Data @ 25°C  
Arrangem ents: 2 Form C (DPDT).  
Hum idity: 85% relative humidity, non-condensing.  
Material: Silver-cadmium oxide alloy.  
Rating: 10A @ 30VDC or 277VAC, resistive; 1/2 HP @ 250VAC; 1/3 HP @  
120VAC.  
Mechanical Data  
Term ination: 11-pin octal style plug.  
Expected Mechanical Life: 10 million operations.  
Expected Electrical Life: 100,000 operations, min., at rated load.  
Enclosure: Beige plastic 1/16 DIN case.  
Sockets: Fits either 27E123 or 27E892 (snap-on) screw terminal sockets.  
Weight: 4.3 oz. (122g) approximately.  
External Control: CONTROL, RESET: Active on contact closure or solid  
state switch closure to RETURN, 0-1.0VDC maximum  
voltage level (see wiring diagrams for interface circuits.  
Initial Dielectric Strength  
Betw een Open Contacts: 1,000V rms, 60 Hz.  
Betw een All Other Conductors: 1,500V rms, 60Hz.  
Ordering Inform ation – Authorized distributors are m ore likely to stock boldface item s listed below .  
Accessories  
Universal Input Model  
Part Num ber  
Nam e  
Description  
Input Voltage  
Part Num ber  
CNT-35-96  
SSA-24C667 Mounting Clip  
Ratchet-fit clip slides onto CNT from behind  
to secure CNT in panel mount applications.  
24-240VAC/VDC  
Fixed Input Models  
Input Voltage  
SSA-24C668 Protective Cover Clear, flexible cover slips snugly over bezel of  
CNT to help protect against dust and moisture.  
Part Num ber  
Durable cover also helps prevent inadvertant  
changes of programming switch settings.  
12VDC  
120VAC  
CNT-35-26  
CNT-35-76  
Outline Dim ensions  
Wiring Diagram s (Bottom View s)  
(pins num bered clockw ise from keyw ay)  
1.88  
(47.8)  
2.83  
(71.9)  
EXTERNAL CONTROL SWITCHES**  
RESET  
CONTROL  
RETURN  
.32  
(8.1)  
CONTROL  
(COUNT)  
RETURN  
RESET  
O
NC  
N
USE SAME  
FOR RESET  
1.88  
(47.8)  
1. 76  
(44.7)  
1
11  
1
11  
A
1
1
1
H
_
INPUT*  
_
+
INPUT*  
+
*
Note: Input polarity for DC operation. For most reliable operation on AC, connect high side  
.64  
(16.3)  
to “+” and low side to “–”.  
** Im portant: A dry circuit switch is recommended. A “dry circuit” switch is one rated to  
reliably switch currents of less than 50mA. Use of a switch rated for other  
than dry circuit may result in failure of the time delay relay to function properly.  
Fits 1.77 x 1.77 (45 x 45)  
Panel cutout  
3.15  
(80.0)  
Dimensions are shown for  
reference purposes only.  
Dimensions are in inches over  
(millimeters) unless otherwise  
specified.  
Specifications and availability  
subject to change.  
www.tycoelectronics.com  
Technical support:  
Refer to inside back cover.  
1211  
Catalog 1308242  
Issued 3-03  
P&B  
Protective Cover & Mounting Clip Dim ensions  
SSA-24C668  
Protective Cover  
SSA-24C667  
Mounting Clip  
1.99  
.40  
(50.5)  
(10.2)  
“A  
2.283  
(58.0)  
1.970  
(50.0)  
2.047  
(52.0)  
1.99  
(50.5)  
.591  
(15.0)  
1.654  
(42.0)  
Section "A-A"  
“A  
1.890  
(48.0)  
Program m ing Sw itch Diagram  
With this setting, the relay would operate after a delay period of 214 seconds.  
A
2
1
4
S
Function Select:  
Tim er Mode:  
A = Delay On Operate  
B = Delay On Release  
C = Interval On  
E = Recycle  
F = Single Cycle  
G = Control On-Off Interval On  
H = Control On-Off Delay  
I = Pulse  
J = Cumulative Delay On Operate  
D = Control-Off Interval On  
Counter Mode:  
B = Divide by 10  
C = Divide by 100  
A & D-J = Normal Count  
Tim e/Counter Setting: 001 to 999  
Tim e Base/Counter Mode Select:  
Tim e Base:  
.1S = 0.1 to 99.9 Sec. .1M = 0.1 to 99.9 Min.  
= 1 to 999 Sec. = 1 to 999 Min.  
CR = Release at Preset Count  
.1H = 0.1 to 99.9 Hrs.  
H = 1 to 999 Hrs.  
10H =10 to 9990 Hrs.  
S
M
Counter Mode: CO = Operate at Preset Count  
Tim er Function Descriptions  
A . Delay On Operate  
Output relay turned on at end of programmed time interval which is started  
by CONTROL input or power-on with CONTROL on. Relay turned off by  
RESET input until next cycle is started. With CONTROL on, turning RESET  
off restarts timing  
started by momentary CONTROL input or power-on with CONTROL  
on. Relay stays on for equal time interval, then turns off. RESET  
terminates timing and turns relay off. Turning RESET off does not restart  
timing.  
G. Control On-Off Interval On (Watch Dog Tim er)  
B. Delay On Release  
Output relay turned on and programmed time interval started or restarted  
by change of CONTROL input. RESET turns relay off and stops timing.  
Turning RESET off does not restart timing.  
Output relay turned on with CONTROL input and remains on for programmed  
time interval following removal of CONTROL. During time interval after  
release of CONTROL, RESET turns relay off until cycle restarted with  
reapplication of CONTROL. With CONTROL on, relay is held off while  
RESET is activated.  
H. Control On-Off Delay  
Output relay turned on at end of programmed timing interval which is  
started or restarted by change of CONTROL input. If relay is on, turn-off  
of relay occurs at end of programmed time interval which is started or  
restarted by change of CONTROL input. RESET turns relay off and stops  
timing. Turning RESET off does not restart timing.  
C. Interval On  
Output relay turned on for programmed time interval by CONTROL or power-  
on with CONTROL on. RESET turns relay off until next cycle is started, and  
does not restart timing when RESET is removed.  
I. Pulse  
D. Control-Off Interval On  
Output relay turned on at end of programmed time interval, which is  
started by CONTROL input, for 0.5 second duration, and continues in  
pulsed mode at programmed time interval with fixed 0.5 second on-time.  
Turning CONTROL off turns relay off and stops timing. RESET turns relay  
off and inhibits operation. With CONTROL on, removal of RESET restarts  
timing.  
Output relay turned on for programmed time interval by turn-off of CON-  
TROL. RESET turns relay off until next cycle is started, and does not restart  
timing when RESET is removed.  
E. Recycle  
Output relay turned on at end of programmed time interval which is started  
by momentary CONTROL input or power-on with CONTROL on. Relay stays  
on for equal time interval, then turns off and cycle is repeated on a free-  
running basis until terminated by momentary RESET, turning relay off. With  
CONTROL on, turning RESET off restarts cycle.  
J . Cum ulative Delay On Operate  
Output relay turned on at completion of total accumulate CONTROL input  
duration equal to programmed time. Turning CONTROL off before  
accumulation of programmed time results in measured time total being  
held until CONTROL is again turned on and total programmed time value  
is reached. RESET input resets time value to zero and turns relay off if  
energized. Turning RESET off restarts timing if CONTROL is on.  
F. Single Cycle  
Output relay turned on at end of programmed time interval which is  
Counter Function Descriptions  
CO – Operate at Preset Count – Norm al Mode  
CR – Release at Preset Count – Norm al Mode  
Initializing by momentary activation of RESET input turns relay on. Operation  
is similar to CO (Operate at Preset Count) except relay turns off at a preset  
count.  
After initializing by momentary activation of RESET input, each on/off signal  
at COUNT (CONTROL) input increments displayed count in upcounting  
manner from initial 000 value until preset count, set by thumbwheel  
switches, is reached and output relay turns on. Additional inputs continue to  
increment displayed count. Continued counting past maximum count (999)  
results in a wrap-around” effect to 000, followed by contrinued up-counting.  
Activation of RESET input turns relay off and resets count to zero.  
CO or CR – Divide-by-10 Mode  
Operation is as described previously, except count is incremented for every  
10 on/off input signals for a maximum presettable count of 9,990.  
CO or CR – Divide-by-100 Mode  
Operation is as described previously, except count is incremented for every  
100 on/off input signals for a maximum presettable count of 99,900.  
Dimensions are shown for  
reference purposes only.  
Dimensions are in inches over  
(millimeters) unless otherwise  
specified.  
Specifications and availability  
subject to change.  
www.tycoelectronics.com  
Technical support:  
Refer to inside back cover.  
1212  

相关型号:

CNT1

TRANSISTOR | BJT | NPN | 80V V(BR)CEO | 800MA I(C) | TO-18
ETC

CNTL9XS102M

Data Line Filter, 1 Function(s)
MURATA

CNU004P-030-1001

Power Connectors for AdvancedTCA
YAMAICHI

CNU004P-030-4001

Power Connectors for AdvancedTCA
YAMAICHI

CNU004S-030-1001

Power Connectors for AdvancedTCA
YAMAICHI

CNU004S-030-4001

Power Connectors for AdvancedTCA
YAMAICHI

CNU009P-096-1001

Power Connectors for MicroTCA
YAMAICHI

CNU009S-096-1001

Power Connectors for MicroTCA
YAMAICHI

CNU109S-020-0010

SFP CONNECTOR,20P,SMT
YAMAICHI

CNW11AV-1

Transistor Output Optocoupler, 1-Element, 4000V Isolation,
QT

CNW11AV-1.300

Transistor Output Optocoupler, 1-Element, 4000V Isolation,
QT

CNW11AV-1.3S

Transistor Output Optocoupler, 1-Element, 4000V Isolation
FAIRCHILD