HF324 [TE]

Signal and RF Relays; 信号和RF继电器
HF324
型号: HF324
厂家: TE CONNECTIVITY    TE CONNECTIVITY
描述:

Signal and RF Relays
信号和RF继电器

继电器
文件: 总12页 (文件大小:1942K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
HF3 Relay  
108-98000  
Sept 06 Rev. C  
ECOC: JM10  
AXICOM  
Telecom-, Signal and RF Relays  
108-98000 Rev. C  
HF3 Relay  
Index  
Dimensions  
4
5
6
Coil Operating Range  
Coil Data and Ordering Informations  
Contact Data  
7
Insulation  
7
General Data  
7
UL 508  
File No. E 111441  
Packing  
10  
UL 60950  
All specifications subject to change. Consult Tyco Electronics for latest specifications.  
ꢀ of 1ꢀ  
AXICOM  
Telecom-, Signal and RF Relays  
108-98000 Rev. C  
HF3 Relay  
High performance low cost plastic sealed high frequency  
relay for 50 and 75 Ohm systems, 1 pole, polarized coil  
Surface Mount Technology (SMT)  
Relay types: non latching  
latching 1 coil  
latching 2 coils  
ROHS compliant (Directive 2002/95/EC) all date codes.  
Features  
Y-Design  
Frequency range DC to 3 GHz  
Impendance 50 Ω or 75 Ω  
Small dimensions (14.6 mm x 7.2 mm x 10 mm)  
1 change over contact (1 form C / SPDT)  
Immersion cleanable  
Low power consumption (140 mW)  
Typical applications  
Cable modems and linecards/ CATV  
TAP's  
Measurement and test equipment ATE  
Satellite / audio / video tuners  
Wireless base stations and antennas  
All specifications subject to change. Consult Tyco Electronics for latest specifications.  
3 of 1ꢀ  
AXICOM  
Telecom-, Signal and RF Relays  
108-98000 Rev. C  
HF3 Relay  
Dimensions  
Dimensions in mm  
50 Ohm Version  
75 Ohm Version  
AXICOM  
HF3 27  
24V DC 10640  
CZECH  
AXICOM  
HF3 27  
24V DC 10640  
CZECH  
Solder pad layout View onto the component side of the PCB (Top view)  
Dimensions in mm  
50 Ohm Version  
75 Ohm Version  
All specifications subject to change. Consult Tyco Electronics for latest specifications.  
ꢁ of 1ꢀ  
AXICOM  
Telecom-, Signal and RF Relays  
108-98000 Rev. C  
HF3 Relay  
Terminal assignment  
Relay top view  
Non-latching type,  
Latching type, 1 coil  
Latching type, 2 coils  
not energized condition  
rest condition  
reset condition  
Coil Operating Range  
140 mW  
70 mW  
3.5  
140 mW  
70 mW  
3
Umax. at 0 A  
Umax. at 0 A  
2.5  
2
1.5  
1
Unom. nominal coil voltage  
Unom. nominal coil voltage  
Uop. min.  
Urel. min.  
0.5  
0
Uop. min.  
-55 -45 -35 -25 -15 -5  
5
15 25 35 45 55 65 75 85 95 105 115 125 135  
Ambient Temperature [°C]  
Ambient Temperature [°C]  
Unom  
Umax.  
=
=
Nominal coil voltage  
Upper limit of the operative range of  
the coil voltage (limiting voltage)  
Lower limit of the operative range of  
Uop. min.  
=
=
the coil voltage (reliable operate voltage)  
For latching relays Uset min. resp. Ureset min.  
Lower limit of the operative range of  
the coil voltage (reliable release voltage)  
Urel. min.  
All specifications subject to change. Consult Tyco Electronics for latest specifications.  
ꢂ of 1ꢀ  
AXICOM  
Telecom-, Signal and RF Relays  
108-98000 Rev. C  
HF3 Relay  
Coil Data (values at 23 °C)  
Ordering Information  
Nominal  
voltage  
Unom  
Operate/set voltage range  
Release/  
reset voltage  
Minimum  
Coil  
power  
Coil  
Resistance  
Relay  
code  
Tyco part  
number  
Minimum  
Maximum  
voltage Umin  
voltage Umax  
Vdc  
Vdc  
Vdc  
Vdc  
mW  
/ 10 ꢀ  
Non-Latching, 1 coil, 50 Ω version  
3
2.25  
3.38  
3.75  
4.50  
6.75  
9.00  
18.00  
6.50  
9.80  
0.30  
0.45  
0.50  
0.60  
0.90  
1.20  
2.40  
140  
140  
140  
140  
140  
140  
140  
64  
145  
HF3 51  
HF3 52  
HF3 53  
HF3 54  
HF3 55  
HF3 56  
HF3 57  
1462051-1  
1-1462051-6  
1462051-2  
1-1462051-7  
1462051-3  
1462051-4  
1462051-5  
4.5  
5
10.90  
13.00  
19.60  
26.10  
52.30  
178  
6
257  
9
574  
12  
24  
1028  
4114  
Latching, 1 coil, 50 Ω version  
3
2.25  
3.38  
3.75  
4.50  
6.75  
9.00  
18.00  
9.20  
13.85  
15.30  
18.50  
27.70  
37.00  
74.00  
2.25  
3.38  
3.75  
4.50  
6.75  
9.00  
18.00  
70  
70  
70  
70  
70  
70  
70  
128  
289  
HF3 71  
HF3 72  
HF3 73  
HF3 74  
HF3 75  
HF3 76  
HF3 77  
1462051-6  
1-1462051-8  
1462051-7  
1-1462051-9  
1462051-8  
1462051-9  
1-1462051-0  
4.5  
5
357  
6
514  
9
1157  
2057  
8228  
12  
24  
Latching, 2 coils, 50 Ω version  
3
2.25  
3.38  
3.75  
4.50  
6.75  
9.00  
18.00  
6.50  
9.80  
2.25  
3.38  
3.75  
4.50  
6.75  
9.00  
18.00  
140  
140  
140  
140  
140  
140  
140  
64  
145  
HF3 91  
HF3 92  
HF3 93  
HF3 94  
HF3 95  
HF3 96  
HF3 97  
1-1462051-1  
2-1462051-0  
1-1462051-2  
2-1462051-1  
1-1462051-3  
1-1462051-4  
1-1462051-5  
4.5  
5
10.90  
13.00  
19.60  
26.10  
52.30  
178  
6
257  
9
574  
12  
24  
1028  
4114  
Non-Latching, 1 coil, 75 Ω version  
3
2.25  
3.38  
3.75  
4.50  
6.75  
9.00  
18.00  
6.50  
9.80  
0.30  
0.45  
0.50  
0.60  
0.90  
1.20  
2.40  
140  
140  
140  
140  
140  
140  
140  
64  
145  
HF3 01  
HF3 02  
HF3 03  
HF3 04  
HF3 05  
HF3 06  
HF3 07  
1462050-1  
1-1462050-6  
1462050-2  
1-1462050-7  
1462050-3  
1462050-4  
1462050-5  
4.5  
5
10.90  
13.00  
19.60  
26.10  
52.30  
178  
6
257  
9
574  
12  
24  
1028  
4114  
Latching, 1 coil, 75 Ω version  
3
2.25  
3.38  
3.75  
4.50  
6.75  
9.00  
18.00  
9.20  
13.85  
15.30  
18.50  
27.70  
37.00  
74.00  
2.25  
3.38  
3.75  
4.50  
6.75  
9.00  
18.00  
70  
70  
70  
70  
70  
70  
70  
128  
289  
HF3 21  
HF3 22  
HF3 23  
HF3 24  
HF3 25  
HF3 26  
HF3 27  
1462050-6  
1-1462050-8  
1462050-7  
1-1462050-9  
1462050-8  
1462050-9  
1-1462050-0  
4.5  
5
357  
6
514  
9
1157  
2057  
8228  
12  
24  
Latching, 2 coils, 75 Ω version  
3
2.25  
3.38  
3.75  
4.50  
6.75  
9.00  
18.00  
6.50  
9.80  
2.25  
3.38  
3.75  
4.50  
6.75  
9.00  
18.00  
140  
140  
140  
140  
140  
140  
140  
64  
145  
HF3 41  
HF3 42  
HF3 43  
HF3 44  
HF3 45  
HF3 46  
HF3 47  
1-1462050-1  
2-1462050-0  
1-1462050-2  
2-1462050-1  
1-1462050-3  
1-1462050-4  
1-1462050-5  
4.5  
5
10.90  
13.00  
19.60  
26.10  
52.30  
178  
6
257  
9
574  
12  
24  
1028  
4114  
Values given are valid for the coil at ambient temperature of 23 °C after preenergizing with nominal voltage without contact current.  
All specifications subject to change. Consult Tyco Electronics for latest specifications.  
ꢃ of 1ꢀ  
AXICOM  
Telecom-, Signal and RF Relays  
108-98000 Rev. C  
HF3 Relay  
Contact Data  
Number of contacts and type  
Contact material  
1 changeover (SPDT)  
Silver, gold-covered  
2 A  
Limiting continuous current at max. ambient temperature  
Maximum switching current  
2 A  
Maximum swichting voltage  
220 Vdc / 250 Vac  
60 W / 62.5 VA / 50 W (2.5 GHz)  
< 100 mΩ  
Maximum switching capacity  
Initial contact resistance at10 mA / 20 mV  
Mechanical endurance  
107 operations  
Insulation  
Insulation resistance at 500 VDC  
> 100 MΩ  
Dielectric test voltage (1 min)  
between coil and contacts  
between open contacts  
1000 Vrms  
600 Vrms  
Surge voltage resistance according to FCC 68 (10 / 160 μs)  
and (2 / 10 μs)  
between coil and contacts  
between open contacts  
1500 V  
1000 V  
General Data  
Operate time at Unom typ./max.  
3 ms / 5 ms  
3 ms / 5 ms  
2 ms / 4 ms  
Reset time (latching) at Unom typ. / max.  
Release time without diode in parallel (non-latching) typ./max.  
Release time with diode in parallel (non-latching) typ./max.  
Bounce time at closing contact typ. / max.  
Maximum switching rate without load  
Ambient temperature  
4 ms / 6 ms  
1 ms / 3 ms  
50 operations/s  
-55 °C ... +85 °C  
> 165 K/W  
Thermal resistance  
Maximum permissable coil temperature  
Vibration resistance (function)  
125 °C  
35 G  
10 to 1000 Hz  
Shock resistance, half sinus, 11 ms  
50 G (function)  
150 G (damage)  
Degree of protection / Environmental protection  
Needle flame test  
immersion cleanable, IP 67 / RT III  
application time 20 s, burning time < 15 s  
Mounting position  
any  
Processing information  
Ultrasonic cleaning is not recommended  
Weight (mass)  
max. 2,5 g  
SnCu 0.7  
MSL 3  
Terminal surface  
Moisture sensitive level (JEDEC J-STD-020B)  
Resistance to soldering heat  
265 °C/10 s  
All specifications subject to change. Consult Tyco Electronics for latest specifications.  
ꢄ of 1ꢀ  
AXICOM  
Telecom-, Signal and RF Relays  
108-98000 Rev. C  
HF3 Relay  
High Frequency Data  
RF characteristics  
Isolation at 100 MHz / 900 MHz / 3 GHz  
50 Ω  
75 Ω  
-80dB / -72dB / -45dB  
-0.03dB / -0.12dB / -0.35dB  
1.05 / 1.15 / 1.20  
-80dB / -72dB / -40dB1  
-0.03dB / -0.12dB / -0.4dB1  
1.05 / 1.20 / 1.401  
Insertion loss at 100 MHz / 900 MHz / 3 GHz  
V.S.W.R. at 100 MHz / 900 MHz / 3 GHz  
1 Values given at frequency of 2.5 GHz  
50 Ohm Version  
75 Ohm Version  
0
-20  
-40  
0
-20  
-40  
NO  
NC  
NO  
-60  
-60  
NC  
-80  
-80  
-100  
-120  
-100  
-120  
0
500  
1000  
1500  
2000  
2500  
0
500  
1000  
1500  
2000  
2500  
3000  
Frequency [Mhz]  
Frequency [Mhz]  
0.1  
0.0  
0.1  
0.0  
NO  
NC  
-0.1  
-0.2  
-0.3  
-0.4  
NC  
-0.1  
-0.2  
-0.3  
-0.4  
NO  
0
500  
1000  
1500  
2000  
2500  
0
500  
1000  
1500  
Frequency [Mhz]  
2000  
2500  
3000  
Frequency [Mhz]  
1.25  
1.20  
1.15  
1.10  
1.05  
1.00  
1.25  
1.20  
1.15  
1.10  
1.05  
1.00  
NC  
NO  
NC  
NO  
2000  
0
500  
1000  
1500  
2500  
3000  
0
500  
1000  
1500  
2000  
2500  
Frequency[Mhz]  
Frequency[Mhz]  
All specifications subject to change. Consult Tyco Electronics for latest specifications.  
ꢅ of 1ꢀ  
AXICOM  
Telecom-, Signal and RF Relays  
108-98000 Rev. C  
HF3 Relay  
Recommended Soldering Conditions  
Soldering conditions according IEC 60058-2-58 and IPC/JEDEC J-STD-020B  
20 - 40 sec  
Full line:  
typical  
240 °C  
180 °C  
Dotted line: process limits  
forced  
cooling  
130 °C  
external preheating  
100 °C  
Vapor Phase Soldering: Temperature/Time Profile  
(Lead and Housing Peak Temperature)  
Time (s)  
Recommended reflow soldering profile  
Infrared Soldering: Temperature/Time Profile  
(Lead and Housing Peak Temperature)  
Time (s)  
Resistance to soldering heat - Reflow profile  
Infrared Soldering: Temperature/Time Profile  
(Lead and Housing Peak Temperature)  
Time (s)  
All specifications subject to change. Consult Tyco Electronics for latest specifications.  
ꢆ of 1ꢀ  
AXICOM  
Telecom-, Signal and RF Relays  
108-98000 Rev. C  
HF3 Relay  
Packing  
Dimensions in mm  
Tape and reel for SMT version  
400 relays / reel  
400 or 2’000 relays / box  
Reel dimension  
All specifications subject to change. Consult Tyco Electronics for latest specifications.  
10 of 1ꢀ  
AXICOM  
Telecom-, Signal and RF Relays  
108-98000 Rev. C  
HF3 Relay  
IM Relays  
D2n Relays  
4th generation slim line – low profile polarized 2 c/o telecom relay with  
bifurcated contacts, available as non latching or latching relay with 1  
coil. Nominal voltage range from 1.5 ... 24 V, coil power consumption of  
50 ... 200 mW, latching relays with 1 coil 100 mW. The IM relay is availa-  
ble as through hole and surface mount type (J-Legs and Gull Wings)  
and capable to switch loads up to 60 W/62,5 VA. It is currently the only  
2 A rated 4G relay on the market. Dielectric strength fulfills the Telcordia  
requirements according GR 1089 (2,5 kV – 2 / 10 μs) and FCC part 68  
(1,5 kV – 10 / 160 μs). The IM relay is tested according CECC/IECQ and  
certified in accordance with IEC/EN 60950 and UL 60950. Dimensions  
approx. 10 x 6 mm board space and 5.65 mm height.  
2nd generation non polarized 2 c/o relay for telecom and various  
other applications. Nominal voltage range from 3 ... 48 V, coil pow-  
er consumption from 150 .... 500 mW. The D2n relay is capable to  
switch currents up to 3 A. Dielectric strength fulfills the requirements  
according FCC part 68 (1,5 kV – 10 / 160 μs). Dimensions approx. 20  
x10 mm board space and 11 mm height.  
P1 Relays  
Extremely sensitive, polarized 1 c/o relay with bifurcated contacts for a  
wide range of applications, available as non latching or latching relay  
with 1 or 2 coils. Nominal voltage range from 3 ... 24 V, coil power  
consumption 65 mW, latching relays with 1 coil 30 mW. The P1 relay  
is available as through hole or surface mount type and capable to  
switch currents up to 1 A. Dielectric strength fulfills the requirements  
according FCC part 68 (1,5 kV – 10 / 160 μs). Dimensions approx. 13  
x 7,6 mm board space and 7 mm height for THT or 8 mm height for  
SMT version.  
P2 Relays  
3rd generation polarized 2 c/o telecom relay with bifurcated contacts,  
available as non latching or latching relay with 1 or 2 coils. Nominal  
voltage range from 3 ... 24 V, coil power consumption 140 mW, lat-  
ching relays with 1 coil 70 mW. The P2 Relay is available as through  
hole or surface mount type and capable to switch currents up to 5 A.  
Dielectric strength fulfills the Telcordia requirements according GR  
1089 (2,5 kV – 2 / 10 μs) and FCC part 68 (1,5 kV – 10 / 160 μs). The P2  
relay is tested according CECC/IECQ and certified in accordance with  
IEC/EN 60950 and UL 60950. Dimensions approx. 15 x 7,5 mm board  
space and 10 mm height.  
W11 Relays  
Low cost, non polarized 1 c/o relay for various applications. Nominal  
voltage range from 3 ... 24 V, coil power consumption 450 mW, sen-  
sitive versions 200 mW. The W11 relay is capable to switch currents  
up to 3 A. Dielectric strength 1000 Vrms. Dimensions approx. 15,6 x  
10,6 mm board space and 11,5 mm height.  
FX2 Relays  
3rd generation polarized 2 c/o telecom relay with bifurcated contacts,  
available as non latching or latching relay with 1 coil. Nominal voltage  
range from 3 ... 48 V, coil power consumption of 80 ... 260 mW for  
the high sensitive version, 140... 300 mW for the standard version,  
latching relays with 1 coil 100 mW. The FX2 relay is available as  
through hole type and capable to switch loads up to 60 W/62,5 VA.  
Dielectric strength fulfills the Telcordia requirements according GR  
1089 (2,5 kV – 2 / 10 μs) and FCC part 68 (1,5 kV – 10 / 160 μs). The  
FX2 relay is tested according CECC/IECQ and certified in accordance  
with IEC/EN 60950 and UL 60950. Dimensions approx. 15 x 7,5 mm  
board space and 10,7 mm height.  
Reed Relays  
High sensitive, non polarized relay for telecom and various other  
applications, available with 1 n/o, 2 n/o or 1c/o contacts. Nominal  
voltage range from 5 ... 24 V, coil power consumption 50...280 mW  
for 1 n/o and 125 ... 280 mW for 2 n/o or 1 c/o versions. Reedrelays are  
available in DIP or SIL housing and capable to switch currents up to  
0,5 A. Integrated diode and/or electrostatic shield optional. Dielectric  
strength 1500 Vdc. Dimensions approx. 19,3 x 7 mm board space and  
5 ... 7,5 mm height for DIP or 19,8 x 5 mm board space and 7,8 mm  
height for SIL version.  
Cradle Relays  
FT2 / FU2 Relays  
Extremely reliable and mature relay family of 1st generation for  
various signal switching applications. Available as non polarized,  
polarized / latching and relay with AC coil. The benefit is the possibility  
of combining various contact sets from 1 up to 6 poles, single and bi-  
furcated contacts, different contact materials with a coil voltage range  
from 1,5 Vdc to 220 Vac. Cradle relays are available as dust protected  
and hermetically sealed versions, with plug in or solder terminals  
and are capable to switch currents up to 5 A. Forcibly guided (linked)  
contact sets optional. Dielectric strength 500 Vrms. Dimensions from  
approx. 19 x 24 to 19x35 mm board space and 30 mm height.  
3rd generation non polarized, non latching 2 c/o telecom relay with  
bifurcated contacts. Nominal voltage range from 3 ... 48 V, coil power  
consumption 200 ... 300 mW. Most sensitive 48 V relay. Available as  
through hole and surface mount type. Dielectric strength fulfills the  
Telcordia requirements according GR 1089 (2,5 kV – 2 / 10 μs) and FCC  
part 68 (1,5 kV – 10 / 160 μs). The FT2/FU2 relay is tested according  
CECC/IECQandcertifiedinaccordancewithIEC/EN60950andUL60950.  
Dimensions approx. 15 x 7,5 mm board space and 10 mm height.  
FP2 Relays  
3rd generation polarized 2 c/o telecom relay with bifurcated contacts,  
available as non latching or latching relay with 1 or 2 coils. Nominal  
voltage range from 3 ... 48 V, coil power consumption of 80 ... 260  
mW for the high sensitive version, 140... 300 mW for the standard  
version, latching relays with 1 coil 100 mW.. The FP2 Relay is available  
as through hole type and capable to switch loads up to 60 W/62,5 VA.  
Dielectric strength fulfills FCC part 68 (1,5 kV – 10 / 160 μs). The FP2  
is tested according CECC/IECQ approved. Dimensions approx. 14 x  
9 mm board space and 5 mm height.  
Other Relays  
We offer a variety of different relay families for maintenance and  
replacement purposes. These relays are up to 60 years old now, such  
as Card Relay SN (V23030 / V23031 series), Small General Purpose  
Relay (V23006 series), Small Polarized Relay (V23063 ... V23067 and  
V23163 ... V23167 series). Accessories like sockets, hold down springs,  
etc. optional.  
HF3 Relay  
High performance low cost RF relay with excellent RF characteristics.  
Available with an impedance of 50 and 75 Ohm. Suitable for frequen-  
cies up to 3 GHz. Actually smallest RF relay available combining small  
size, excellent RF performance and SMD solderability. Available as non  
latching or latching relay with 1 or 2 coils and a nominal coil voltage  
range from 3 ... 24 V, coil power consumption 140 mW, latching relays  
with 1 coil 70 mW. Dimensions 14.6 x 7.3 x 10 mm.  
MT2  
2nd generation non polarized, non latching 2 c/o telecom and si-  
gnal relay with bifurcated contacts. Nominal voltage range from  
3 ... 48 V, coil power consumption 150/200/300/400 and 550 mW.  
Dielectric strength fulfills the requirements according FCC part 68  
(1,5 kV – 10 / 160 μs).  
Dimensions approx. 20 x 10 mm board space and 11 mm height.  
All specifications subject to change. Consult Tyco Electronics for latest specifications.  
11 of 1ꢀ  
Tyco Electronics Logistics AG  
Werk Axicom Au  
Seestrasse 295  
CH-8804 Au-Wädenswil / Switzerland  
Phone +41 44 782 91 11  
Fax  
+41 44 782 90 00  
E-mail: axicom@tycoelectronics.com  
Tyco Electronics  
Paulsternstrasse 26  
D-13629 Berlin / Germany  
Phone +49 30 386 38573  
Fax  
+49 30 386 38575  
E-mail: axicom@tycoelectronics.com  
Tyco Electronics EC Trutnov s.r.o.  
Komenského 821  
CZ-541 01 Trutnov / Czech Republic  
E-mail: axicom@tycoelectronics.com  
Tyco Electronics Corporation  
POB 3608,  
Harrisburg, PA 17105, USA  
Phone +1 800-522-6752  

相关型号:

HF324J

Heavy Duty Safety Switches
ETC

HF324N

Heavy Duty Safety Switches
ETC

HF324NR

Heavy Duty Safety Switches
ETC

HF324S

Heavy Duty Safety Switches
ETC

HF325

Signal and RF Relays
TE

HF325J

Heavy Duty Safety Switches
ETC

HF325N

Heavy Duty Safety Switches
ETC

HF325NH

Heavy Duty Safety Switches
ETC

HF325NR

Heavy Duty Safety Switches
ETC

HF325NRH

Heavy Duty Safety Switches
ETC

HF325S

Heavy Duty Safety Switches
ETC

HF326

Signal and RF Relays
TE