KHAU-17A11B-12 [TE]
General Purpose Dry Circuit to 5A Multicontact AC or DC Relay; 通用小功率电路,以5A多触点交流或直流继电器型号: | KHAU-17A11B-12 |
厂家: | TE CONNECTIVITY |
描述: | General Purpose Dry Circuit to 5A Multicontact AC or DC Relay |
文件: | 总4页 (文件大小:113K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
KHA series
General Purpose
Dry Circuit to 5A
Multicontact
AC or DC Relay
File E22575
File LR15734
KHS
KHAU
Coil Data @ 25°C
Features
Voltage: From 6 to 120VDC, and 6 to 240VAC, 50/60 Hz.
Nom . Pow er: DC coils - 0.9 watt; 0.5 watt minimum operate @ 25°C.
AC coils - 1.2 VA; 0.55 VA minimum operate @ 25°C.
Max. Pow er: DC coils - 2.0 watts @ 25°C.
• Miniature size from 2 pole to 4 pole.
• KHAU is produced on an automated line, while KHU is produced
manually. Form, fit and function of the two versions are identical.
• KHS hermetically sealed version UL Approved for Class 1 Division 2
hazardous locations.
Duty Cycle: Continuous.
Initial Breakdow n Voltage: 500V rms, 60 Hz.
• Various applications include process control, photocopier, and data
processing.
• Push-to-test and inidcator options available.
• Various contact materials available for specific load requirements.
Coil Data
DC Coils
AC Coils
Resistance
in Ohm s
±10% @
250C
Nom inal
Inductance
in Henrys
Resistance
in Ohm s
±15%
Nom inal
AC Current
in m A
Nom inal
Voltage
Contact Data @ 25°C
5
6
12
24
48
110 *
120 *
240
32
40
160
.072
.08
.28
1.0
4.5
17.0
—
—
—
10.5
43
160
668
—
200
100
52
25
—
Arrangem ents: 2 Form C (DPDT), 4 Form C (4PDT).
Expected Life: 10 million operations, mechanical; 100,000 operations min.
at rated loads. Ratings are based on tests of relays with
ungrounded frames.
Initial Breakdow n Voltage: 500V rms, 60 Hz., between open contacts.
1240V rms, 60 Hz., between all other
650
2,600
11,000
—
—
3,900
12,000
11.0
6.0
elements.
—
*Note: For 220 and 240VDC, use series dropping 5W resistor of 11,000Ω.
Contact Ratings
Resistive Rating
Contact
Material
Code
Operate Data @ 25°C
Must-Operate Voltage: DC: 75% of nominal voltage.
AC: 85% of nominal voltage.
Minim um
Maxim um
1
2*
3
Silver
100mA @
3A @
Operate Tim e: 13 milliseconds typical @ nominal voltage (excluding
12VAC/12VDC
120VAC/28VDC
bounce).
Release Tim e: 6 milliseconds typical @ nominal voltage (excluding
Silver-cadmium
oxide
500mA @
5A @
bounce).
12VAC/12VDC
120VAC/28VDC
Gold-silver-nickel
10mA @
2A @
12VAC/12VDC
120VAC/28VDC
6
Bifurcated cross bar,
gold overlay silver
Dry circuit
1A @
120VAC/28VDC
Environm ental Data
Tem perature Range: -45°C to +70°C operate.
-60°C to +130°C storage.
8
Gold diffused silver
50mA @
3A @
12VAC/12VDC
120VAC/28VDC
Note: Relays should only carry a maximum of 15 amps continuously for all poles combined.
Mechanical Data
Mountings: #3-48 stud, sockets with printed circuit or solder terminals,
or bracket plate with #6-32 threaded stud.
Term ination: Printed circuit or solder/socket terminals.
Printed circuit terminals are available for KHS on a special
order basis.
KHS Contact Ratings
Class I Division II Hazardous Location:
5A@28VDC/120VAC
UL 508 (Industrial Control):
3A@28VDC/120VAC; 1/10 HP @ 120VAC.
Enclosures: See Ordering Information table.
Weight: 1.6 oz. approx. (45g).
Ordering Inform ation
Typical Part No. B
KHA
U
-17
A
1
1
B
-24
1. Basic Series: (See Note 1)
2. Type:
E = Printed circuit terminals, nylon dust cover, contacts rated opposite polarity (UL & CSA).
S = Solder terminals, hermetically sealed steel case (UL & CSA). Note: Do not ground
KHS frame without consulting factory for load levels. (Order as KHS, not KHAS.)
U = Solder terminals, clear polycarbonate dust cover, contacts rated same polarity
(UL & CSA).
3. Contact Arrangem ent:
11 = 2 Form C (DPDT)
17 = 4 Form C (4PDT)
4. Operating Coil:
A = AC
D = DC
5. Mounting and Term ination:
1 = Socket mount, solder terminals on S, U types; printed circuit terminals on E types.
6. Contact Material:
Relay Type
E
S
U
Available Codes
1, 2, 3,
6, 8
1*, 2*,
3
1, 2,
6, 8
*UL Rated 1/10 HP, 3A, 120VAC when used with mounting & termination 1.
1 = Silver.
3 = Gold-silver-nickel.
8 = Gold diffused silver.
2 = Silver-cadmium oxide.
6 = Bifurcated crossbar, gold overlay silver.
7. Options Available:
Relay Type
E
S
U
N
B
Available Codes B (DPDT only)
None
H
L
M
B = Push to test button.
N = Neon indicator. Only available with 120VAC or 110VDC coils. Not available with mounting & termination 4 or 8.
H = Neon indicator and push to test button. Only available with 120VAC or DC coils. Not available with mounting & termination 4 or 8.
L = LED indicator. Only available with 6-48VDC coils.
M = LED indicator and push-to-test button. Only available with 6-48VDC coils.
8. Coil Voltage:
6, 12, 24, 48, 120, 240**VAC
6, 12, 24, 48, 110VDC
**240VAC coil is not available on KHS type relays.
Note 1: Some KHA models available in KH construction. Specify KH instead of KHA.
Stock Item s - The follow ing item s are norm ally m aintained in stock for im m ediate delivery.
KHAE-17D12-24
KHAU-11A11-120
KHAU-11D11-24
KHAU-17A11-12
KHAU-17A11-24
KHAU-17A11-120
KHAU-17A11N-120
KHAU-17A12-120
KHAU-17A13-120
KHAU-17A16-24
KHAU-17A16-120
KHAU-17A18-120
KHAU-17D11-6
KHAU-17D11-24
KHAU-17D11-48
KHAU-17D11-110
KHAU-17D12-12
KHAU-17D12-24
KHAU-17D12-48
KHAU-17D12-110
KHAU-17D16-12
KHAU-17D16-24
KHS-17A11-24
KHS-17D11-48
KHS-17D11-110
KHS-17D12-12
KHS-17D12-24
KHS-17A11-120
KHS-17A12-120
KHS-17D11-12
KHAU-17D11-12
KHS-17D11-24
Outline Dim ensions
Mounting Code 1 - KHAU only.
Mounting Code 1 - KHS only.
2 & 4 Pole
2 & 4 Pole
.859 MAX.
(21.82)
.750
.910 MAX.
(23.11)
.250 + .015
(6.35 ± .38)
.45 REF.
(11.4)
.25
(6.4)
(19.05)
1
5
2
6
3
7
4
8
#3-48
THREAD
.022 REF
(.56)
.022
(.56)
1.109 MAX.
(28.17)
1.156 MAX.
(29.36)
#3-48 THREAD
9
10 11 12
.168
(4.27)
.000 - .010
(.00 - .25)
.263
(6.68)
.263 REF.
(6.68)
.265
(6.73)
1.281 MAX.
(32.54)
.525
(13.34)
.281 REF.
(7.14)
.312
(7.92)
1.281 MAX.
(32.54)
.525 REF.
(13.34)
.421
(10.69)
.312 + .031
(7.92 ± .79)
PC terminal models have rivet, not stud.
Max. seated height in 27E006 socket is
1.37" (34.8mm).
Class 1 Div. 2 Group A, B, C & D Hazards
Mounting Code 1 - Neon Indicator, Push-To-Test.
Printed Circuit
Term inals
.859 MAX.
(21.82)
.750
(19.05)
.168 ± 020
(4.27 ± .51)
.250
(6.35)
.797 ± .020
(20.24 ± .51)
.125 DIA.
(3.18)
.313
(7.95)
.040 ± .010
(1.02 ± .25)
.052 REF.
(1.32)
1
5
2
6
3
7
4
8
.168
(4.27)
#3-48 THREAD
9
10 11 12
.112
(2.84)
.265 ± .046
(6.73 ± 1.17)
.047
REF.
(1.19)
1.281 MAX.
(32.54)
1.600 MAX WITH
INDICATOR LAMP
(38.10)
.421 ± .046
(10.69 ± 1.17)
.219
(5.56)
.263
(6.68)
Printed circuit terminal thickness .022 (.558)
.312 ± .031
(7.92 ± .79)
.525
(13.34)
.180 DIA. BOSSES
(4.57)
Wiring Diagram s (Bottom View s)
2 Pole
4 Pole
3
4
1
5
2
1
5
4
8
6
7
8
9
10
11
12
9
13
+
12
13
14
14
+
-
-
+ = Polarity for LED indicator.
PC Board Layout (Bottom View )
.160
(4.06)
.410
(10.41)
.660
For KHAE Relays
with PC terminals
and sockets with
PC terminals
(16.76)
14
.175
PLACES
.070 DIA.
(4.45)
(1.78)
.350
(8.89)
.525
(13.34)
Sockets For KHA And KHS Series
All sockets are normally maintained in stock for immediate delivery.
4-Pole Socket
For KHAU, KHAX, KHS Relays.
Relays wilth solder terminals are required for use with sockets.
.068
(1.73)
Socket Description
.183
(4.65)
Industrial
Part No.
No. of
Poles
Term inal
and Length
Grounding
Provision
Socket
Material
1.150
(29.21)
27E006*
27E007*
4
4
Solder .375"
(9.53mm)
Yes
Yes
No
Nylon
Nylon
Nylon
.012
(0.30)
P.C. .218"
(5.54mm)
.310
(7.87)
27E023*
27E220*
4
2
P.C. .218"
(5.54mm)
1.07
(2.72)
.850
(21.59)
.440
(11.18)
27E166**
27E894**
4
Screw
Yes
No
Glass-filled
Polyester
4
Screw
Glass-filled
Polyester
Recom m ended Chassis Cutouts
For Mounting Sockets
20C217
20C297
Relay Hold Down Spring
Relay Hold Down Spring
(use with 27E166 &
27E894)
.858
(21.79)
*
UL Recognized, file E22575
Recommended Chassis Thickness
.031 (.79) to .062 (1.57)
** UL Recognized, file E59244
1. 015
(25.78)
Pierced Solder Term inals
Mounting Strip 37D633
Socket punch Greenlee part
5015115.0, Type 731R available
from Greenlee Tool Co.,
1.388
(35.26)
.629
(15.98)
1.323
Rockford, Illinois. (4-pole)
.090 R.
(2.29)
1.388
(35.26)
.25
(33.60)
.125 ± .010
(3.18 ± 0.25)
(6.4)
.617
Printed Circuit Term inals
With Grounding Lug
(15.67)
1.750
GROUND
LUG
(44.45)
1. 015
.171
(4.34)
.105
(2.67)
(25.78)
.090
(2.29)
.052 ± .010
(1.32 ± 0.25)
.218 ± .016
(5.54 ± 0.41)
.429
(10.90)
.16
(4.1)
.180
(4.57)
.061
(1.55)
GROUND
LUG
.858
(21.79)
.32
(8.1)
.065
(1.65)
.13
(3.3)
Without Grounding Lug
37D633 will mount eight solder terminal sockets
in one length of aluminum strip measuring 10.97" x 2.25" x .062
(278.6 x 57.15 x 1.57)
.171
(4.34)
.218 ± .016
(5.54 ± 0.41)
Screw Term inal Socket 27E166
Relays with solder terminals are required for use
with screw terminal sockets.
Screw Term inal DIN Rail,
Snap-Mount Socket 27E894
(Use with mounting track 24A110)
.061
(1.55)
.236
(5.99)
1.181
(30.00)
M3 SCREWS &
CAPTIVE WASHERS
.800 MAX.
.94
(23.88)
(20.32)
.446 REF.
(11.33)
Caution: Printed circuit sockets are manufactured with
"floating" (Loose) terminals. This permits them to align
with holes in the circuit board and with the relay terminals.
During the mounting and soldering of the socket, vertical
float should be eliminated and the terminals seated on the
board. (This may be accomplished by inserting a dummy
relay in the socket.) Failure to eliminate float may cause
fracture of the solder joint or separation of the copper
conductor from the printed circuit board when a relay is
inserted in the socket after soldering.
.709
(18.01)
.47
(11.93)
.165
(4.19)
1.18
(30.0)
1. 771
(44.98)
2.441
(62.00)
2.363 MAX.
(60.02)
.140 TYP.
(3.56)
.210 TYP.
(5.33)
.728
(18.49)
.118
(3.00)
1.024
(26.01)
Hold Dow n
Spring 20C217
# 4-40 SCREWS &
CAPTIVE WASHERS
.984
(24.99)
.600
(15.24)
1.22 MAX.
(30.99)
27E894
Term inal
Location
27E166
Term inal
Location
8
7
6 5
8
7
6
5
4 3
2 1
4
3
2
1
14
13
14
12 11 10
Top View
G
13
12
Top View
9
11 10
9
Tyco Electronics Corporation - P&B, Winston-Salem, NC 27102
Technical Support Center: 1-800-522-6752, www.pandbrelays.com
Specifications and availability subject to change without notice.
13C5420 Printed in U.S.A. IH/3-00
相关型号:
©2020 ICPDF网 联系我们和版权申明