LVR040S [TE]

PolySwitch PTC Devices Overcurrent Protection Device; PTC的PolySwitch设备过电流保护装置
LVR040S
型号: LVR040S
厂家: TE CONNECTIVITY    TE CONNECTIVITY
描述:

PolySwitch PTC Devices Overcurrent Protection Device
PTC的PolySwitch设备过电流保护装置

装置 过电流保护
文件: 总2页 (文件大小:87K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Tyco/Electronics  
Raychem Circuit Protection  
308 Constitution Drive  
Menlo Park, CA 94025-1164  
800-227-4856  
PRODUCT: LVR040S  
PolySwitch®  
DOCUMENT: SCD 24906  
PTC Devices  
PCN: 336638  
Overcurrent Protection Device  
REV LETTER: E  
REV DATE: MARCH 21, 2003  
PAGE NO.: 1 OF 2  
FAX 800-227-4866  
Specification Status:RELEASED  
Electrical Rating at 20ºC  
Rated Operating Voltage: 240 VAC  
Rated Interrupt Current: 5.5 ARMS  
Max Interrupt Voltage: 265 VAC  
Insulating Material :  
Cured, Flame Retardant Epoxy Polymer  
Meets UL94 V-0 Requirements.  
Lead Material: 22 AWG Sn Plated Copper  
Marking:  
Raychem Logo  
and Voltage  
240  
Part Identification  
L040  
Lot Identification  
(can be on back)  
TABLE I. DIMENSIONS:  
A
B
C
D
E
MIN  
--  
MAX  
11.5  
(0.46  
MIN  
--  
--  
MAX  
19.5  
(0.77)  
MIN  
4.3  
(0.17)  
MAX  
5.8  
MIN  
7.6  
MAX  
--  
MIN  
--  
MAX  
3.8  
(0.15)  
mm:  
in*:  
--  
(0.23) (0.30)  
*Rounded off approximation  
TABLE II. PERFORMANCE RATINGS:  
IHOLD  
CURRENT RATINGS  
TIME TO TRIP  
RESISTANCE  
POST-TRIP  
RESISTANCE  
STANDARD  
TRIP  
NOMINAL  
TRIPPED  
POWER  
RATED  
CURRENT  
DISSIPATION  
WATTS  
AMPS AT  
20oC  
AMPS  
SECONDS AT  
20oC, 2.0A  
MAX  
OHMS  
OHMS  
AT 20oC  
AT 20oC  
AT 20oC  
MAX  
AT 20oC  
HOLD  
HOLD  
0.40  
TRIP  
0.90  
MIN  
0.6  
MAX  
0.97  
0.40  
24.0  
1.9  
2.0  
Recognitions:  
UL, TUV recognized.  
PS300  
Reference Documents:  
Precedence:  
Effectivity:  
This specification takes precedence over documents referenced herein.  
Reference documents shall be the issue in effect on the date of invitation for bid.  
Refer to Page 2 of this document for application limitations.  
Warning:  
Tyco/Electronics  
Raychem Circuit Protection  
308 Constitution Drive  
Menlo Park, CA 94025-1164  
800-227-4856  
PRODUCT: LVR040S  
PolySwitch®  
DOCUMENT: SCD 24906  
PTC Devices  
PCN: 336638  
Overcurrent Protection Device  
REV LETTER: E  
REV DATE: MARCH 21, 2003  
PAGE NO.: 2 OF 2  
FAX 800-227-4866  
Warning: Application Limitations for the LVR Product Line  
1. Users should independently evaluate the suitability of and test each product selected for their  
own application.  
2. This product should not be used in an application where the maximum interrupt voltage or  
maximum interrupt current can be exceeded in a fault condition. Operation beyond the  
maximum ratings or improper use may result in device damage and possible electrical arcing  
and flame.  
3. A PTC device is not a fuse - it is a nonlinear thermistor that limits current. Because under a  
fault condition all PTC devices go into a high resistance state but not open circuit, hazardous  
voltage may be present at PTC locations.  
4. The devices are intended for protection against occasional overcurrent or overtemperature  
fault conditions and should not be used when repeated fault conditions or prolonged trip events  
are anticipated.  
5. In most applications, power must be removed and the fault condition cleared in order to reset a  
PTC device. However, under certain unusual conditions, a PTC device may automatically  
reset (see Raychem Circuit Protection Databook). Accordingly, PTC devices should not be  
used in an application where an automatic reset could create a safety hazard, such as garbage  
disposals and blenders.  
6. It is the responsibility of the user to determine the need for back up or fail safe protection to  
prevent damage that may occur in the event of abnormal function or failure of the PTC device.  
7. Operation in circuits with a large inductance can generate a circuit voltage (Ldi/dt) above the  
rated voltage of a PTC device.  
8. Devices are not recommended for reflow soldering.  
9. Device performance can be impacted negatively if devices are handled in a manner  
inconsistent with recommended electronic, thermal, or mechanical procedures for electronic  
components.  
10. PTC devices are not recommended to be installed in applications where the device is  
constrained such that its PTC properties are inhibited, for example in rigid potting materials or  
in rigid housings which lack adequate clearance to accommodate device expansion.  
11. Contamination of the PTC material with certain silicone-based oils or some aggressive  
solvents can adversely impact the performance of the devices.  

相关型号:

LVR040S-1

PTC Resettable Fuse, Through Hole Mount, RADIAL LEADED, ROHS COMPLIANT
LITTELFUSE

LVR040S-2

PolySwitch Resettable Devices
TE

LVR055

PolySwitch Resettable Devices Line-Voltage-Rated Devices
MACOM

LVR055K

PolySwitch Resettable Devices
TE

LVR055K

PolySwitch Resettable Devices Line-Voltage-Rated Devices
MACOM

LVR055L000FB12

RESISTOR, CURRENT SENSE, METAL STRIP, 5 W, 1 %, 0.005 ohm, THROUGH HOLE MOUNT, AXIAL LEADED
VISHAY

LVR055L000FE70

RESISTOR, CURRENT SENSE, METAL STRIP, 5 W, 1 %, 0.005 ohm, THROUGH HOLE MOUNT, AXIAL LEADED, LEAD FREE
VISHAY

LVR055L000FE73

RESISTOR, CURRENT SENSE, METAL STRIP, 5 W, 1 %, 0.005 ohm, THROUGH HOLE MOUNT, AXIAL LEADED, GREEN
VISHAY

LVR055L000FS73

RESISTOR, CURRENT SENSE, METAL STRIP, 5 W, 1 %, 0.005 ohm, THROUGH HOLE MOUNT, AXIAL LEADED
VISHAY

LVR055L000HE12

RESISTOR, CURRENT SENSE, METAL STRIP, 5 W, 3 %, 0.005 ohm, THROUGH HOLE MOUNT, AXIAL LEADED, GREEN
VISHAY

LVR055L000HE70

RESISTOR, CURRENT SENSE, METAL STRIP, 5 W, 3 %, 0.005 ohm, THROUGH HOLE MOUNT, AXIAL LEADED, LEAD FREE
VISHAY

LVR055L000HE73

RESISTOR, CURRENT SENSE, METAL STRIP, 5 W, 3 %, 0.005 ohm, THROUGH HOLE MOUNT, AXIAL LEADED, GREEN
VISHAY