Pressure Transducer  
SPECIFICATIONS  
Analog Outputs (V/mA)  
14-Bit Digital Output for Pressure and 11-Bit for  
Temperature  
CE Compliance  
Weatherproof  
0.5% zero offset,1.5 % accuracy (Total error band)  
The M3200 pressure transducer from the Microfused line of TE is  
suitable for measurement of liquid or gas pressure, even for  
difficult media such as contaminated water, steam, and mildly  
corrosive fluids.  
FEATURES  
The transducer pressure cavity is machined from a solid piece of  
17-4PH stainless steel. The standard version includes a 1/4 NPT  
pipe thread allowing a leak-proof, all metal sealed system. With  
excellent durability, there are no welds or organics exposed to the  
pressure media.  
One Piece Stainless Steel Construction  
Digital Pressure and Temperature Output  
or Analog mV/Amplified Output  
Compact  
17-4PH Stainless Steel  
Customizable  
TE’s proprietary Microfused technology, derived from demanding  
aerospace applications, employs micromachined silicon  
piezoresistive strain gages fused with high temperature glass to a  
stainless-steel diaphragm. This approach achieves media  
compatibility simply and elegantly while providing an exceptionally  
stable sensor without the PN junctions of conventional  
micromachined sensors.  
APPLICATIONS  
Pumps and Compressors  
Hydraulic/Pneumatic Systems  
Automotive Test Systems  
Energy and Water Management  
Medical Gas Pressure  
Leak Detection  
Remote Measuring Systems  
General Pressure Measurements  
This product is geared towards industrial and commercial OEMs  
for small to high volume applications. Standard configurations are  
suitable for many applications. Please contact factory for your  
customization needs.  
08/2018  
SENSOR SOLUTIONS ///M3200  
Page 1  
M3200  
Pressure Transducer  
STANDARD RANGES  
Range (psi)  
0 to 100  
0 to 250  
0 to 500  
0 to 01k  
0 to 2k5  
0 to 05k  
0 to 7k5  
0 to 10k  
Range (bar)  
0 to 007  
0 to 017  
0 to 035  
0 to 070  
0 to 170  
0 to 350  
0 to 500  
0 to 700  
Gage/Compound  
PERFORMANCE SPECIFICATIONS (ANALOG)  
Unless otherwise specified: All parameters measured at 25°C  
PARAMETERS  
MIN  
TYP  
MAX  
0.25  
0.5  
UNITS  
NOTES  
Accuracy  
-0.25  
% F.S BFSL  
(Combined linearity, hysteresis & repeatability)  
Zero offset  
Pressure Cycles  
-0.5  
1.0E+6  
2X  
%F.S.  
0~F.S. Cycles  
Rated  
Rated  
MΩ  
@ 25°C  
Proof Pressure  
Burst Pressure  
5X  
≤20kpsi  
Isolation, Body to Any Lead  
Load Resistance (RL)  
Load Resistance  
50  
@ 250VDC  
>100  
<(Supply Voltage-9V)/0.02A  
kΩ  
Voltage Output  
Current Output  
Voltage Output  
@500 VAC 1 min  
Current Consumption  
Dielectric Strength  
Long Term Stability (1 year)  
Total Error Band  
5
2
mA  
mA  
-0.25  
0.25  
1.5  
85  
%Span  
%F.S.  
°C  
-1.5  
-20  
Over comp. temp  
Compensated Temperature  
Except Cable  
105°C max  
Operating Temperature  
Storage Temperature  
-40  
-40  
125  
125  
°C  
°C  
Except Cable  
105°C max  
Weather proof Rating  
Rise Time (10% - 90%)  
Wetted Material  
Shock  
IP67 for cable & M12 type, IP66 for Packard type, IP65 for Form C type  
<2 ms (mV Output); <3ms (mA Output)  
Note 1  
17-4PH Stainless Steel  
50g, 11 msec Half Sine Shock per MIL-STD-202G, Method 213B, Condition A  
20g, MIL-STD-810C, Procedure 514.2-2, Curve L  
Vibration  
Compliances6  
EN 55022 Emissions Class A & B  
IEC 61000-4-2 Electrostatic discharge immunity (4kv contact / 8kv air discharge)  
IEC 61000-4-3 Radiated, Radio-Frequency Electromagnetic field immunity (10 V/m; 80M-1GHz; 3 V/m, 1.4 – 2.0GHz; 1 V/m, 2.0 – 2.7GHz)  
IEC 61000-4-4 Electrical Fast Transient/Burst Immunity (±1kV)  
IEC 61000-4-5 Surge (line to line: ±1.0kV/42Ω; Line to case: ±1.0kV/42Ω)  
IEC 61000-4-6 Immunity to conducted disturbances, induced by radio-frequency fields (150k-80MHz, 3VRMS for current output model,  
10VRMS for voltage model)  
08/2018  
SENSOR SOLUTIONS ///M3200  
Page 2  
M3200  
Pressure Transducer  
PERFORMANCE SPECIFICATIONS (DIGITAL)  
Unless otherwise specified: All parameters measured at 25°C & 3.3vDC  
PARAMETERS  
Output at Zero Pressure  
Output at FS Pressure  
Current Consumption  
Current Consumption (sleep mode)  
Supply Voltage  
MIN  
TYP  
MAX  
1250  
15250  
3.5  
UNITS  
Count  
Count  
mA  
NOTES  
750  
1000  
14720  
15000  
5
µA  
2.7  
2X  
5.0  
V
Proof Pressure  
Rated  
No More than  
20kpsi  
Burst Pressure  
5X  
Rated  
Isolation, Body to Any Lead  
Pressure Cycles  
50  
MΩ  
@ 250VDC  
1.00E+6  
0~F.S. Cycles  
Pressure Accuracy (RSS combined  
Non-Linearity, Hysteresis &  
Repeatability)  
-0.25  
0.25  
%F.S. BFSL  
@ 25°C  
Note 2  
Temperature Accuracy  
Long Term Stability (1 year)  
Total Error Band  
-3  
-0.25  
-1.5  
0
3
°C  
%F.S.  
%F.S.  
°C  
0.25  
1.5  
Over comp Temp.  
For reference  
Compensated Temperature  
Compensated Temperature Output  
Operating Temperature  
55  
512  
-20  
-40  
1075  
+85  
+85  
Count  
°C  
Storage Temperature  
°C  
Non-sleep mode,  
note 3  
Response time  
3
ms @ 4MHz  
ms @ 4MHz  
Response time  
Wetted Material (except elastomer seal)  
Shock  
8.4  
Sleep mode, note 3  
17-4PH Stainless Steel  
50g, 11 msec Half Sine Shock per MIL-STD-202G, Method 213B, Condition A  
Weather proof Rating3  
IP67  
Vibration  
20g, MIL-STD-810C, Procedure 514.2-2, Curve L  
Compliance6  
EN 55011 Emissions Class A & B  
IEC 61000-4-2 Electrostatic Discharge Immunity (4kV contact/8kV air discharge)  
IEC 61000-4-3 Radiated Radio-Frequency Electromagnetic Field Immunity (1V/m, 80M-1GHz; 3 V/m, 1.4 – 2.0GHz; 1V/m,  
2.0-2.7GHz)  
IEC 61000-4-4 Electrical Fast Transient/Burst Immunity (±1kV)  
IEC 61000-4-6 immunity to conducted disturbances, induced by radio-frequency fields (150k-80MHz, 3VRMS  
)
Notes  
1. Weather-proof ratings are met when the mating connectors are properly installed and cable termination to dry and clean area.  
For Cable option, IP67 is guaranteed under room temperature.  
2. Reflect pressure port diaphragm temperature over the compensated temperature range.  
3. Response time is from power on to reading measurement data.  
4. For all CE compliance test, max allowed output deviation is 1.5%F.S.  
5. All Configurations are built with Voltage Reverse and output Short-Circuit Protections.  
6. For communication and interfacing, refer to document ‘Interfacing to MEAS Digital Pressure Modules’ online  
08/2018  
SENSOR SOLUTIONS ///M3200  
Page 3  
M3200  
Pressure Transducer  
DIMENSIONS  
Digital Output I2C Wiring  
Connection +Supply  
-Supply  
BLACK  
3
SCL  
WHITE  
4
SDA  
GREEN  
2
Cable  
M12  
RED  
1
Current Output Wiring  
Connection  
+Supply  
-Supply  
NC. Pins  
PREF Vent  
Packard A  
A
B
C
Hole through  
connector  
Packard B  
B
1
A
2
C
Hole through  
connector  
Form C  
3, 4  
Thread through  
connector  
Cable  
M12  
Red  
1
Black  
3
-
In Cable  
2,4  
Hole through  
connector  
Voltage Output Wiring  
Connection  
+Supply  
-Supply  
+Output  
-Output  
NC.  
PREF Vent  
Pins*  
Packard A  
Packard B  
Form C  
Cable  
A
B
B
A
C
-
-
-
Hole through Connector  
Hole through Connector  
Thread through Connector  
In Cable  
C
3
-
1
2
-
4
-
Red  
1
Black  
3
White  
2
Not connected  
M12  
4
Hole through Connector  
08/2018  
SENSOR SOLUTIONS ///M3200  
Page 4  
M3200  
Pressure Transducer  
Notes:  
*NC. Pins are reserved for factory use only. DO NOT CONNECT.  
**For cable connections, drain wire is internally terminated to pressure port.  
drain wire is not available for I2C output option  
*** Cable material4C*22AWG + DRAIN + AL.MYLAR + PVC Jacket  
Transmitter of gage pressure type requires vent to atmosphere on the pressure reference side.  
Accomplished via cable from transmitter or through customer mating connector/cable assembly which has internal vent path  
(end of cable should be terminated to clean & dry area)  
Weather-proof Ratings are met when Mating Connectors are installed properly, and cable termination is to dry and clean area.  
PRESSURE PORTS  
Code  
Pressure Port  
Dim C  
Recommended Torque [Nm]  
7/16-20 UNF Male SAE J1926-2 Straight Thread  
O-Ring BUNA-N 90SH ID8.92xW1.83mm  
4
0.45 [11.43]  
18-20  
5
6
1/4-18 NPT  
1/8-27 NPT  
0.65 [16.51]  
0.53 [13.46]  
0.47 [11.94]  
0.50 [12.70]  
2-3 TFFT*  
2-3 TFFT*  
30-35  
B
E
G1/4 JIS B2351 with NBR O-ring  
1/4-19 BSPT  
2-3 TFFT*  
7/16-20 UNF Female SAE J513 Straight Thread  
w/ Integral Valve Depressor  
P
0.43 [10.92]  
15-16  
*Turn From Finger Tight  
08/2018  
SENSOR SOLUTIONS ///M3200  
Page 5  
 
M3200  
Pressure Transducer  
DIGITAL PRESSURE OUTPUT  
% Output  
0%  
Digital Counts (Decimal)  
Digital Counts (Hex)  
0x3E8  
1000  
1700  
5%  
0X6A4  
10%  
2400  
0X960  
50%  
8000  
0X1F40  
90%  
13600  
14300  
15000  
0X3520  
95%  
0X37DC  
0X3A98  
100%  
08/2018  
SENSOR SOLUTIONS ///M3200  
Page 6  
M3200  
Pressure Transducer  
DIGITAL TEMPERATURE OUTPUT  
Output °C  
Digital Counts (Decimal)  
Digital counts  
0x200  
0
512  
614  
10  
25  
40  
55  
0x266  
767  
0x2FF  
921  
0x399  
1075  
0x433  
08/2018  
SENSOR SOLUTIONS ///M3200  
Page 7  
M3200  
Pressure Transducer  
OUTPUT (ANALOG)  
Code  
Output  
0.5 4.5V  
4 20mA  
0 5 V  
Supply  
Ratiometricity  
Red  
Black  
Common  
-Supply  
-Supply  
-Supply  
-Supply  
Green  
White  
3
5
6
7
8
5
0.25V  
Yes  
No  
No  
No  
No  
+Supply  
+Supply  
+Supply  
+Supply  
+Supply  
Not connected  
+Output  
9 30V  
Not connected Not connected  
8 30V  
Not connected  
Not connected  
Not connected  
+Output  
+Output  
+Output  
0 10 V  
1 5 V  
12 30 V  
8 30 V  
OUTPUT (DIGITAL)  
Code  
J
Output  
I2C  
Supply  
Red  
+Supply  
Black  
Green  
SDA  
White  
2.7 5.0V  
-Supply  
SCL  
08/2018  
SENSOR SOLUTIONS ///M3200  
Page 8  
M3200  
Pressure Transducer  
ORDERING INFORMATION  
For Analog Output:  
M32 3 4 00000 4 250P G  
Pressure Type  
Gage  
Output  
G
C
Code  
Output  
0.5-4.5V  
4-20mA  
0-5V  
Compound  
3
5
6
7
8
Compound pressure range is -14.7 to XXX psiG or -1 to XXX barG.  
i.e. 200PC: -14.7 to 200psiG, 020BC: -1 to 20 barG  
0-10V  
1~5V  
Pressure Range  
psi  
STD  
100P  
bar  
STD  
007B  
Connection  
4
6
Packard A Connector  
Form C with Mating Connector  
Packard B Connector  
M12 Connector  
Cable 0.5m  
250P  
500P  
01KP  
2K5P  
05KP  
7K5P  
10KP  
017B  
035B  
070B  
170B  
350B  
500B  
700B  
9
D
L
M
N
P
Cable 1m  
Cable 2m  
Cable 5m  
Pressure Ranges between 100-10000psi (7-700bar) are all available. Change  
Pressure Number Accordingly  
Snubber  
Pressure Port  
0
1
No snubber  
Code Description  
With snubber*  
7/16-20 UNF Male SAE J1926-2 Straight Thread  
4
O-ring 90SH ID8.92xW1.83mm  
*Available for G1/4 port only, more snubber option, please consult with factory  
5
6
1/4-18 NPT  
1/8-27 NPT  
For Digital Output, see “For Digital Output” Ordering Information  
All Configurations are built with Voltage Reverse and Output Short-Circuit Protections.  
B
E
G1/4 JIS B2351 with NBR O-ring  
1/4-19 BSPT  
7/16-20 UNF Female SAE J513 Straight Thread  
with Integral Valve Depressor  
P
Click here for Torque Recommendation  
08/2018  
SENSOR SOLUTIONS ///M3200  
Page 9  
M3200  
Pressure Transducer  
For Digital Output:  
M32 J L 000 0 0 4 250P G  
Output  
Pressure Type  
Gage  
Code  
J
Output  
I2C  
G
C
Compound  
Compound pressure range is -14.7 to XXX psiG or -1 to XXX barG.  
Ex. 200PC: -14.7 to 200psiG, 020BC: -1 to 20 barG  
Connection  
Cable 0.5m  
Cable 1m  
L
M
D
Pressure Range  
M12 connector  
psi  
STD  
100P  
bar  
STD  
007B  
Snubber  
250P  
500P  
01KP  
2K5P  
05KP  
7K5P  
10KP  
017B  
035B  
070B  
170B  
350B  
500B  
700B  
0
No snubber  
With snubber*  
1
*Available for G1/4 port only,More snubber options, please consult with factory.  
Sleep Mode (Digital ONLY)  
0
1
Non-Sleep Mode  
Sleep Mode  
Pressure Ranges between 100-10000psi (7-700bar) are all  
available. Change Pressure Number Accordingly  
Pressure Port  
Code Description  
Digital Address (Digital ONLY)  
7/16-20 UNF Male SAE J1926-2 Straight Thread  
O-ring BUNA-N 90SH ID8.92xW1.83mm  
0
1
2
3
4
0X28H  
0X36H  
0X46H  
0X48H  
0X51H  
4
5
6
1/4-18 NPT  
1/8-27 NPT  
B
E
G1/4 JIS B2351 with NBR O-ring  
1/4-19 BSPT  
7/16-20 UNF Female SAE J513 Straight Thread  
with Integral Valve Depressor  
P
Click here for Torque Recommendation  
All Configurations are built with Voltage Reverse and Output Short-Circuit Protections.  
ASIA  
EUROPE  
NORTH AMERICA  
Measurement Specialties (China), Ltd.,  
a TE Connectivity Company  
Phone: +86 0400-820-6015  
Measurement Specialties (Europe), Ltd.,  
a TE Connectivity Company  
Phone: +31 73 624 6999  
Measurement Specialties, Inc.,  
a TE Connectivity Company  
Phone: +1 800-522-6752  
Email: customercare.shzn@te.com  
Email: customercare.lcsb@te.com  
Email: customercare.frmt@te.com  
TE.com/sensorsolutions  
Measurement Specialties, Inc., a TE Connectivity company.  
Measurement Specialties, TE Connectivity, TE Connectivity (logo) and EVERY CONNECTION COUNTS are trademarks. All other logos, products and/or company names referred to herein  
might be trademarks of their respective owners.  
The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE Connectivity makes  
no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity‘s obligations shall only be as set forth in TE Connectivity‘s Standard  
Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse  
of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application.  
© 2018 TE Connectivity Ltd. family of companies All Rights Reserved.  
08/2018  
SENSOR SOLUTIONS ///M3200  
Page 10  

M323M-01000P-100PG 相关器件

型号 制造商 描述 价格 文档
M323M-01000P-250PG TE Pressure Transducer 获取价格
M323M-01000P-2K5PG TE Pressure Transducer 获取价格
M323M-01000P-500PG TE Pressure Transducer 获取价格
M323N-000004-01KPG TE Pressure Transducer 获取价格
M323N-000004-05KPG TE Pressure Transducer 获取价格
M323N-000004-100PG TE Pressure Transducer 获取价格
M323N-000004-250PG TE Pressure Transducer 获取价格
M323N-000004-2K5PG TE Pressure Transducer 获取价格
M323N-000004-500PG TE Pressure Transducer 获取价格
M323N-000004-7K5PG TE Pressure Transducer 获取价格

M323M-01000P-100PG 相关文章

  • HARTING(浩亭)圆形连接器产品选型手册
    2024-10-31
    6
  • HYCON(宏康科技)产品选型手册
    2024-10-31
    6
  • GREEGOO整流二极管和晶闸管产品选型手册
    2024-10-31
    7
  • 西门子豪掷106亿美元,战略收购工程软件巨头Altair
    2024-10-31
    8