M325P-00000E-100PG 概述
Pressure Transducer
M325P-00000E-100PG 数据手册
通过下载M325P-00000E-100PG数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载M3200
Pressure Transducer
SPECIFICATIONS
Analog Outputs (V/mA)
14-Bit Digital Output for Pressure and 11-Bit for
Temperature
CE Compliance
Weatherproof
0.5% zero offset,1.5 % accuracy (Total error band)
The M3200 pressure transducer from the Microfused line of TE is
suitable for measurement of liquid or gas pressure, even for
difficult media such as contaminated water, steam, and mildly
corrosive fluids.
FEATURES
The transducer pressure cavity is machined from a solid piece of
17-4PH stainless steel. The standard version includes a 1/4 NPT
pipe thread allowing a leak-proof, all metal sealed system. With
excellent durability, there are no welds or organics exposed to the
pressure media.
One Piece Stainless Steel Construction
Digital Pressure and Temperature Output
or Analog mV/Amplified Output
Compact
17-4PH Stainless Steel
Customizable
TE’s proprietary Microfused technology, derived from demanding
aerospace applications, employs micromachined silicon
piezoresistive strain gages fused with high temperature glass to a
stainless-steel diaphragm. This approach achieves media
compatibility simply and elegantly while providing an exceptionally
stable sensor without the PN junctions of conventional
micromachined sensors.
APPLICATIONS
Pumps and Compressors
Hydraulic/Pneumatic Systems
Automotive Test Systems
Energy and Water Management
Medical Gas Pressure
Leak Detection
Remote Measuring Systems
General Pressure Measurements
This product is geared towards industrial and commercial OEMs
for small to high volume applications. Standard configurations are
suitable for many applications. Please contact factory for your
customization needs.
08/2018
SENSOR SOLUTIONS ///M3200
Page 1
M3200
Pressure Transducer
STANDARD RANGES
Range (psi)
0 to 100
0 to 250
0 to 500
0 to 01k
0 to 2k5
0 to 05k
0 to 7k5
0 to 10k
Range (bar)
0 to 007
0 to 017
0 to 035
0 to 070
0 to 170
0 to 350
0 to 500
0 to 700
Gage/Compound
PERFORMANCE SPECIFICATIONS (ANALOG)
Unless otherwise specified: All parameters measured at 25°C
PARAMETERS
MIN
TYP
MAX
0.25
0.5
UNITS
NOTES
Accuracy
-0.25
% F.S BFSL
(Combined linearity, hysteresis & repeatability)
Zero offset
Pressure Cycles
-0.5
1.0E+6
2X
%F.S.
0~F.S. Cycles
Rated
Rated
MΩ
@ 25°C
Proof Pressure
Burst Pressure
5X
≤20kpsi
Isolation, Body to Any Lead
Load Resistance (RL)
Load Resistance
50
@ 250VDC
>100
<(Supply Voltage-9V)/0.02A
kΩ
Voltage Output
Current Output
Voltage Output
@500 VAC 1 min
Ω
Current Consumption
Dielectric Strength
Long Term Stability (1 year)
Total Error Band
5
2
mA
mA
-0.25
0.25
1.5
85
%Span
%F.S.
°C
-1.5
-20
Over comp. temp
Compensated Temperature
Except Cable
105°C max
Operating Temperature
Storage Temperature
-40
-40
125
125
°C
°C
Except Cable
105°C max
Weather proof Rating
Rise Time (10% - 90%)
Wetted Material
Shock
IP67 for cable & M12 type, IP66 for Packard type, IP65 for Form C type
<2 ms (mV Output); <3ms (mA Output)
Note 1
17-4PH Stainless Steel
50g, 11 msec Half Sine Shock per MIL-STD-202G, Method 213B, Condition A
20g, MIL-STD-810C, Procedure 514.2-2, Curve L
Vibration
Compliances6
EN 55022 Emissions Class A & B
IEC 61000-4-2 Electrostatic discharge immunity (4kv contact / 8kv air discharge)
IEC 61000-4-3 Radiated, Radio-Frequency Electromagnetic field immunity (10 V/m; 80M-1GHz; 3 V/m, 1.4 – 2.0GHz; 1 V/m, 2.0 – 2.7GHz)
IEC 61000-4-4 Electrical Fast Transient/Burst Immunity (±1kV)
IEC 61000-4-5 Surge (line to line: ±1.0kV/42Ω; Line to case: ±1.0kV/42Ω)
IEC 61000-4-6 Immunity to conducted disturbances, induced by radio-frequency fields (150k-80MHz, 3VRMS for current output model,
10VRMS for voltage model)
08/2018
SENSOR SOLUTIONS ///M3200
Page 2
M3200
Pressure Transducer
PERFORMANCE SPECIFICATIONS (DIGITAL)
Unless otherwise specified: All parameters measured at 25°C & 3.3vDC
PARAMETERS
Output at Zero Pressure
Output at FS Pressure
Current Consumption
Current Consumption (sleep mode)
Supply Voltage
MIN
TYP
MAX
1250
15250
3.5
UNITS
Count
Count
mA
NOTES
750
1000
14720
15000
5
µA
2.7
2X
5.0
V
Proof Pressure
Rated
No More than
20kpsi
Burst Pressure
5X
Rated
Isolation, Body to Any Lead
Pressure Cycles
50
MΩ
@ 250VDC
1.00E+6
0~F.S. Cycles
Pressure Accuracy (RSS combined
Non-Linearity, Hysteresis &
Repeatability)
-0.25
0.25
%F.S. BFSL
@ 25°C
Note 2
Temperature Accuracy
Long Term Stability (1 year)
Total Error Band
-3
-0.25
-1.5
0
3
°C
%F.S.
%F.S.
°C
0.25
1.5
Over comp Temp.
For reference
Compensated Temperature
Compensated Temperature Output
Operating Temperature
55
512
-20
-40
1075
+85
+85
Count
°C
Storage Temperature
°C
Non-sleep mode,
note 3
Response time
3
ms @ 4MHz
ms @ 4MHz
Response time
Wetted Material (except elastomer seal)
Shock
8.4
Sleep mode, note 3
17-4PH Stainless Steel
50g, 11 msec Half Sine Shock per MIL-STD-202G, Method 213B, Condition A
Weather proof Rating3
IP67
Vibration
20g, MIL-STD-810C, Procedure 514.2-2, Curve L
Compliance6
EN 55011 Emissions Class A & B
IEC 61000-4-2 Electrostatic Discharge Immunity (4kV contact/8kV air discharge)
IEC 61000-4-3 Radiated Radio-Frequency Electromagnetic Field Immunity (1V/m, 80M-1GHz; 3 V/m, 1.4 – 2.0GHz; 1V/m,
2.0-2.7GHz)
IEC 61000-4-4 Electrical Fast Transient/Burst Immunity (±1kV)
IEC 61000-4-6 immunity to conducted disturbances, induced by radio-frequency fields (150k-80MHz, 3VRMS
)
Notes
1. Weather-proof ratings are met when the mating connectors are properly installed and cable termination to dry and clean area.
For Cable option, IP67 is guaranteed under room temperature.
2. Reflect pressure port diaphragm temperature over the compensated temperature range.
3. Response time is from power on to reading measurement data.
4. For all CE compliance test, max allowed output deviation is 1.5%F.S.
5. All Configurations are built with Voltage Reverse and output Short-Circuit Protections.
6. For communication and interfacing, refer to document ‘Interfacing to MEAS Digital Pressure Modules’ online
08/2018
SENSOR SOLUTIONS ///M3200
Page 3
M3200
Pressure Transducer
DIMENSIONS
Digital Output I2C Wiring
Connection +Supply
-Supply
BLACK
3
SCL
WHITE
4
SDA
GREEN
2
Cable
M12
RED
1
Current Output Wiring
Connection
+Supply
-Supply
NC. Pins
PREF Vent
Packard A
A
B
C
Hole through
connector
Packard B
B
1
A
2
C
Hole through
connector
Form C
3, 4
Thread through
connector
Cable
M12
Red
1
Black
3
-
In Cable
2,4
Hole through
connector
Voltage Output Wiring
Connection
+Supply
-Supply
+Output
-Output
NC.
PREF Vent
Pins*
Packard A
Packard B
Form C
Cable
A
B
B
A
C
-
-
-
Hole through Connector
Hole through Connector
Thread through Connector
In Cable
C
3
-
1
2
-
4
-
Red
1
Black
3
White
2
Not connected
M12
4
Hole through Connector
08/2018
SENSOR SOLUTIONS ///M3200
Page 4
M3200
Pressure Transducer
Notes:
*NC. Pins are reserved for factory use only. DO NOT CONNECT.
**For cable connections, drain wire is internally terminated to pressure port.
drain wire is not available for I2C output option
*** Cable material:4C*22AWG + DRAIN + AL.MYLAR + PVC Jacket
Transmitter of gage pressure type requires vent to atmosphere on the pressure reference side.
Accomplished via cable from transmitter or through customer mating connector/cable assembly which has internal vent path
(end of cable should be terminated to clean & dry area)
Weather-proof Ratings are met when Mating Connectors are installed properly, and cable termination is to dry and clean area.
PRESSURE PORTS
Code
Pressure Port
Dim C
Recommended Torque [Nm]
7/16-20 UNF Male SAE J1926-2 Straight Thread
O-Ring BUNA-N 90SH ID8.92xW1.83mm
4
0.45 [11.43]
18-20
5
6
1/4-18 NPT
1/8-27 NPT
0.65 [16.51]
0.53 [13.46]
0.47 [11.94]
0.50 [12.70]
2-3 TFFT*
2-3 TFFT*
30-35
B
E
G1/4 JIS B2351 with NBR O-ring
1/4-19 BSPT
2-3 TFFT*
7/16-20 UNF Female SAE J513 Straight Thread
w/ Integral Valve Depressor
P
0.43 [10.92]
15-16
*Turn From Finger Tight
08/2018
SENSOR SOLUTIONS ///M3200
Page 5
M3200
Pressure Transducer
DIGITAL PRESSURE OUTPUT
% Output
0%
Digital Counts (Decimal)
Digital Counts (Hex)
0x3E8
1000
1700
5%
0X6A4
10%
2400
0X960
50%
8000
0X1F40
90%
13600
14300
15000
0X3520
95%
0X37DC
0X3A98
100%
08/2018
SENSOR SOLUTIONS ///M3200
Page 6
M3200
Pressure Transducer
DIGITAL TEMPERATURE OUTPUT
Output °C
Digital Counts (Decimal)
Digital counts
0x200
0
512
614
10
25
40
55
0x266
767
0x2FF
921
0x399
1075
0x433
08/2018
SENSOR SOLUTIONS ///M3200
Page 7
M3200
Pressure Transducer
OUTPUT (ANALOG)
Code
Output
0.5 – 4.5V
4 – 20mA
0 – 5 V
Supply
Ratiometricity
Red
Black
Common
-Supply
-Supply
-Supply
-Supply
Green
White
3
5
6
7
8
5
0.25V
Yes
No
No
No
No
+Supply
+Supply
+Supply
+Supply
+Supply
Not connected
+Output
9 – 30V
Not connected Not connected
8 – 30V
Not connected
Not connected
Not connected
+Output
+Output
+Output
0 – 10 V
1 – 5 V
12 – 30 V
8 – 30 V
OUTPUT (DIGITAL)
Code
J
Output
I2C
Supply
Red
+Supply
Black
Green
SDA
White
2.7 – 5.0V
-Supply
SCL
08/2018
SENSOR SOLUTIONS ///M3200
Page 8
M3200
Pressure Transducer
ORDERING INFORMATION
For Analog Output:
M32 3 4 – 00000 4 – 250P G
Pressure Type
Gage
Output
G
C
Code
Output
0.5-4.5V
4-20mA
0-5V
Compound
3
5
6
7
8
Compound pressure range is -14.7 to XXX psiG or -1 to XXX barG.
i.e. 200PC: -14.7 to 200psiG, 020BC: -1 to 20 barG
0-10V
1~5V
Pressure Range
psi
STD
100P
bar
STD
007B
Connection
4
6
Packard A Connector
Form C with Mating Connector
Packard B Connector
M12 Connector
Cable 0.5m
250P
500P
01KP
2K5P
05KP
7K5P
10KP
017B
035B
070B
170B
350B
500B
700B
9
D
L
M
N
P
Cable 1m
Cable 2m
Cable 5m
Pressure Ranges between 100-10000psi (7-700bar) are all available. Change
Pressure Number Accordingly
Snubber
Pressure Port
0
1
No snubber
Code Description
With snubber*
7/16-20 UNF Male SAE J1926-2 Straight Thread
4
O-ring 90SH ID8.92xW1.83mm
*Available for G1/4 port only, more snubber option, please consult with factory
5
6
1/4-18 NPT
1/8-27 NPT
For Digital Output, see “For Digital Output” Ordering Information
All Configurations are built with Voltage Reverse and Output Short-Circuit Protections.
B
E
G1/4 JIS B2351 with NBR O-ring
1/4-19 BSPT
7/16-20 UNF Female SAE J513 Straight Thread
with Integral Valve Depressor
P
Click here for Torque Recommendation
08/2018
SENSOR SOLUTIONS ///M3200
Page 9
M3200
Pressure Transducer
For Digital Output:
M32 J L – 000 0 0 4 – 250P G
Output
Pressure Type
Gage
Code
J
Output
I2C
G
C
Compound
Compound pressure range is -14.7 to XXX psiG or -1 to XXX barG.
Ex. 200PC: -14.7 to 200psiG, 020BC: -1 to 20 barG
Connection
Cable 0.5m
Cable 1m
L
M
D
Pressure Range
M12 connector
psi
STD
100P
bar
STD
007B
Snubber
250P
500P
01KP
2K5P
05KP
7K5P
10KP
017B
035B
070B
170B
350B
500B
700B
0
No snubber
With snubber*
1
*Available for G1/4 port only,More snubber options, please consult with factory.
Sleep Mode (Digital ONLY)
0
1
Non-Sleep Mode
Sleep Mode
Pressure Ranges between 100-10000psi (7-700bar) are all
available. Change Pressure Number Accordingly
Pressure Port
Code Description
Digital Address (Digital ONLY)
7/16-20 UNF Male SAE J1926-2 Straight Thread
O-ring BUNA-N 90SH ID8.92xW1.83mm
0
1
2
3
4
0X28H
0X36H
0X46H
0X48H
0X51H
4
5
6
1/4-18 NPT
1/8-27 NPT
B
E
G1/4 JIS B2351 with NBR O-ring
1/4-19 BSPT
7/16-20 UNF Female SAE J513 Straight Thread
with Integral Valve Depressor
P
Click here for Torque Recommendation
All Configurations are built with Voltage Reverse and Output Short-Circuit Protections.
ASIA
EUROPE
NORTH AMERICA
Measurement Specialties (China), Ltd.,
a TE Connectivity Company
Phone: +86 0400-820-6015
Measurement Specialties (Europe), Ltd.,
a TE Connectivity Company
Phone: +31 73 624 6999
Measurement Specialties, Inc.,
a TE Connectivity Company
Phone: +1 800-522-6752
Email: customercare.shzn@te.com
Email: customercare.lcsb@te.com
Email: customercare.frmt@te.com
TE.com/sensorsolutions
Measurement Specialties, Inc., a TE Connectivity company.
Measurement Specialties, TE Connectivity, TE Connectivity (logo) and EVERY CONNECTION COUNTS are trademarks. All other logos, products and/or company names referred to herein
might be trademarks of their respective owners.
The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE Connectivity makes
no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity‘s obligations shall only be as set forth in TE Connectivity‘s Standard
Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse
of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application.
© 2018 TE Connectivity Ltd. family of companies All Rights Reserved.
08/2018
SENSOR SOLUTIONS ///M3200
Page 10
M325P-00000E-100PG 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
M325P-00000E-250PG | TE | Pressure Transducer | 获取价格 | |
M325P-00000E-2K5PG | TE | Pressure Transducer | 获取价格 | |
M325P-00000E-500PG | TE | Pressure Transducer | 获取价格 | |
M325P-00000E-7K5PG | TE | Pressure Transducer | 获取价格 | |
M325P-00000P-01KPG | TE | Pressure Transducer | 获取价格 | |
M325P-00000P-05KPG | TE | Pressure Transducer | 获取价格 | |
M325P-00000P-100PG | TE | Pressure Transducer | 获取价格 | |
M325P-00000P-250PG | TE | Pressure Transducer | 获取价格 | |
M325P-00000P-2K5PG | TE | Pressure Transducer | 获取价格 | |
M325P-00000P-500PG | TE | Pressure Transducer | 获取价格 |
M325P-00000E-100PG 相关文章
- 2024-11-08
- 22
- 2024-11-08
- 15
- 2024-11-08
- 16
- 2024-11-08
- 14