MAP200ARAEA [TE]

Contacts Rated up to 500 Amps, 12-900VDC; 联系方式额定功率高达500安培, 12-900VDC
MAP200ARAEA
型号: MAP200ARAEA
厂家: TE CONNECTIVITY    TE CONNECTIVITY
描述:

Contacts Rated up to 500 Amps, 12-900VDC
联系方式额定功率高达500安培, 12-900VDC

文件: 总2页 (文件大小:109K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MAP200 Series Contactor With 1 Form A (SPST-NO)  
Contacts Rated up to 500 Amps, 12-900VDC  
Product Facts  
Designed to be the smallest,  
lightest weight, lowest cost  
sealed contactor in the industry  
with its current rating.  
Built-in coil economizer  
(models requiring external  
economizer also available).  
Optional auxiliary contact for  
easy monitoring of power  
contact position.  
Hermetically sealed –  
intrinsically safe, operates in  
explosive/harsh environments  
with no oxidation or  
contamination of coils or  
contacts, including long periods  
of non-operation.  
Versatile coil and power  
connections.  
MIL-PRF-32085 versions in  
development  
For factory-direct application assistance, dial  
800-253-4560, ext. 2053, or 805-220-2053.  
Performance Data  
Parameter  
Contact Arrangement, power contacts  
Rated Operating Voltage  
Units Value for MAP200 Series  
1 Form A (SPST-NO)  
VDC 12 - 900  
Coil Operating Voltage (valid over temperature range)  
Voltage (will operate)  
Voltage (Max.)  
18-32VDC  
32VDC  
18VDC  
10VDC  
2VDC  
Continuous (Carry) Current, Typical  
A
500 @ 85°C, 400 mcm conductors  
Pickup (close) Voltage Max.  
Hold Voltage (Min.)  
Consult Factory for required conductors for higher currents  
1/  
Make/Break Current at Various Voltages  
A
A
See next page  
2,000, 1 cycle  
Dropout (open) Voltage (Min.)  
Inrush Current (Max.)  
Holding Current (Avg.)  
Inrush Time (Max.)  
1/  
Break Current at 320VDC  
4.5A  
Contact Resistance, Typ. (@200A)  
Load Life  
Mechanical Life  
mohms 0.2  
Cycles See next page  
Cycles 1 million  
0.5A  
100ms  
Contact Arrangement, auxiliary contacts  
1 Form A (SPST-NO)  
Aux. Contact Current, Max.  
Aux. Contact Current, Min.  
A
2A @ 30VDC / 3A @ 125VAC  
100mA @ 8V  
mA  
Part Numbering System  
Typical Part Number  
Aux. Contact Resistance, Max.  
Dielectric Withstanding Voltage  
Insulation Resistance @ 500VDC  
Shock, 11ms 1/2 sine, peak, operating  
Vibration, sine, 80-2000Hz., peak  
Operating Temperature  
ohms 0.417@ 30VDC / .150 @ 125VAC  
Vrms 2,200 @ sea level  
megohms 100  
G
G
°C  
MAP200  
A
R
D
E
A
Series:  
2/  
MAP200 = 500 Amp, 12-900VDC Contactor  
20  
20  
Contact Form:  
A = Normally Open  
H = Normally Open with Aux. Contacts  
-55 to +85  
Coil Voltage:  
R = 18-32VDC  
Weight, Nominal  
lb.(kg) .95 (.43)  
Coil Wire Length:  
A = 15.3 in (390 mm)  
B = 6.0 in (152 mm)  
1/  
2/  
3/  
Main power contacts  
50 at end of life  
D = Coil connector on relay (requires option “E” or “X” in next step).  
Use with AMP LOUVERTAC 5-192013-9. Consult factory for threaded mount  
Coil Terminal Connector:  
socket.  
N = No connector  
E = 9-pin subminiature “D” plug mounted on contactor housing  
F = 9-pin subminiature “D” plug mounted on 15.3 in (390 mm) flying leads.  
X = Special configuration (consult factory)  
Mounting & Power Terminals:  
A = Bottom Mount & Male M8 x 1.25 Thread Terminals  
B = Bottom Mount & Female 1/4-20 Thread Terminals  
3/  
C = Bottom Mount & Plug-in Terminals  
© 2004 by Tyco Electronics Corporation. All Rights Reserved.  
KILOVAC, AMP, LOUVERTAC and TYCO are trademarks.  
D = Bottom Mount & Female M6 x 1 Thread Terminals  
Other products and company names mentioned herein may be trademarks of their  
respective owners.  
1
Catalog 1654857  
Issued 6-04  
Dimensions are in inches and  
millimeters unless otherwise  
specified. Values in brackets  
are metric equivalents.  
Dimensions are shown for  
reference purposes only.  
Specifications subject  
to change.  
USA: 1-800-522-6752  
South America: 55-11-3611-1514  
Hong Kong: 852-2735-1628  
Japan: 81-44-844-8013  
Canada: 1-905-470-4425  
Mexico: 01-800-733-8926  
C. America: 52-55-5-729-0425  
www.tycoelectronics.com  
UK: 44-141-810-8967  
500 Amp, 12-900VDC Contactor with  
1 Form A (SPST-NO) Contacts  
MAP200 Series (Continued)  
Outline Dimensions  
2.688 ± .01  
(68.28 ± .26)  
1.05 ± .01  
(26.67 ± .26)  
LABEL  
2 X M6 x 1 THREAD  
.45 (11.43) MIN DEPTH (11 THREADS)  
TORQUE VS THREAD ENGAGEMENT  
8 TO 11 THREADS: 80 TO 100 IN-LB (9.1 TO 11.3 NM)  
7 TO 8 THREADS: 70 TO 80 IN-LB (7.9 TO 9.1 NM)  
5 TO 7 THREADS: 60 TO 70 IN-LB (6.8 TO 7.9)  
.800 ± .01  
(20.3 ± .26)  
3.289 ± .025  
(83.54 ± .635)  
2 X 10-32 THREAD THRU  
TORQUE: 15 TO 30 IN-LB (1.7 TO 3.3 NM)  
1.65 ± .01  
(42.0 ± .26)  
WIRE VIEW REMOVED  
FOR CLARITY  
2.245 ± .025  
(57.02 ± .635)  
2.523 ± .025  
(64.08 ± .635)  
1.431 ± .025  
(36.35 ± .635)  
2.20 ± .025  
(55.81 ± .63)  
.546 ± .01  
(13.87 ± .26)  
3.17 ± .01  
(80.48 ± .26)  
Estimated Make & Break Power Switching Ratings  
Electrical Load Life Ratings for Typical Applications  
Make/Break Life Capacitive & Resistive Loads at 320VDC (1) (2)  
Continuous Current Carry Region  
Non-continuous Current Carry Region  
200A  
100,000  
10,000  
1,000  
100  
@90% capacitive pre-charge (make only) see chart below  
@80% capacitive pre-charge (make only) see chart below  
@200A make/break (2 consecutive, reverse polarity) (1)  
2,000A (break only) (1)  
Cycles  
Cycles  
Cycles  
Cycles  
50,000  
50  
12  
1*  
(1) Resistive load includes inductance L = 25µH. Load @ 2500A tested @ 200µH.  
(2) Life based on projected Weibull Life with 95% teliability.  
* Does not meet dielectric and IR after test.  
MAP200 CAPACITIVE MAKE TEST CURVES  
700  
650  
600  
10  
550  
500  
450  
400  
350  
300  
250  
200  
150  
100  
50  
80% Minimum  
Pre Charge  
1
1
10  
100  
1,000  
Load Current (Amps)  
10,000  
NOTES:  
1) FOR RESISTIVE LOADS WITH 300µH MAXIMUM INDUCTANCE.  
90% Nominal  
Pre Charge  
2) ESTIMATES BASED ON EXTRAPOLATED DATA. USER IS ENCOURAGED TO VERIFY RATING IN ACTUAL APPLICATION.  
3) END OF LIFE WHEN DIELECTRIC STRENGTH BETWEEN TERMINALS FALLS BELOW 50MEGOHMS @ 500VDC.  
4) THE MAXIMUM CONTACT MAKE AND BREAK POWER IS ESTIMATED AT 208KW.  
BREAK ONLY ABOVE 208KW TO AVOILD CONTACT WELDING.  
0
0.0  
0.5  
1.0  
1.5  
2.0  
mS  
For factory-direct application assistance, dial  
800-253-4560, ext. 2053, or 805-220-2053.  
1654857 – 2.5M – KRG – FP – 6-04  
Printed in U.S.A.  
2
Dimensions are in inches and  
millimeters unless otherwise  
specified. Values in brackets  
are metric equivalents.  
Dimensions are shown for  
reference purposes only.  
Specifications subject  
to change.  
USA: 1-800-522-6752  
South America: 55-11-3611-1514  
Hong Kong: 852-2735-1628  
Japan: 81-44-844-8013  
Canada: 1-905-470-4425  
Mexico: 01-800-733-8926  
www.tycoelectronics.com  
C. America: 52-55-5-729-0425  
UK: 44-141-810-8967  

相关型号:

MAP200ARAFA

Contacts Rated up to 500 Amps, 12-900VDC
TE

MAP200ARANA

Contacts Rated up to 500 Amps, 12-900VDC
TE

MAP200ARBEA

Contacts Rated up to 500 Amps, 12-900VDC
TE

MAP200ARBFA

Contacts Rated up to 500 Amps, 12-900VDC
TE

MAP200ARBNA

Contacts Rated up to 500 Amps, 12-900VDC
TE

MAP200ARDEA

Contacts Rated up to 500 Amps, 12-900VDC
TE

MAP200ARDFA

Contacts Rated up to 500 Amps, 12-900VDC
TE

MAP200ARDNA

Contacts Rated up to 500 Amps, 12-900VDC
TE

MAP200HRAEA

Contacts Rated up to 500 Amps, 12-900VDC
TE

MAP200HRAFA

Contacts Rated up to 500 Amps, 12-900VDC
TE

MAP200HRANA

Contacts Rated up to 500 Amps, 12-900VDC
TE

MAP200HRBEA

Contacts Rated up to 500 Amps, 12-900VDC
TE