MS583730BA01-50 [TE]

Ultra Small Gel Filled Pressure Sensor;
MS583730BA01-50
型号: MS583730BA01-50
厂家: TE CONNECTIVITY    TE CONNECTIVITY
描述:

Ultra Small Gel Filled Pressure Sensor

文件: 总16页 (文件大小:1314K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MS5837-30BA  
Ultra Small Gel Filled Pressure Sensor  
SPECIFICATIONS  
Ceramic - metal package, 3.3 x 3.3 x 2.75mm  
High-resolution module 0.2 mbar  
Fast conversion down to 0.5 ms  
Low power, 0.6 µA (standby < 0.1 µA at 25°C)  
Integrated digital pressure sensor (24 bit ΔΣ ADC)  
Supply voltage 1.5 to 3.6 V  
Operating range: 0 to 30 bar, -20 to +85 °C  
I2C interface  
No external components (Internal oscillator)  
Excellent long term stability  
Hermetically sealable for outdoor devices  
Sealing designed for 1.8 x 0.8mm O-ring  
The MS5837-30BA is a new generation of high resolution  
pressure sensors with I2C bus interface for depth  
measurement systems with a water depth resolution of 2 mm.  
The sensor module includes a high linearity pressure sensor  
and an ultra-low power 24 bit ΔΣ ADC with internal factory  
calibrated coefficients. It provides a precise digital 24 Bit  
pressure and temperature value and different operation modes  
that allow the user to optimize for conversion speed and  
current consumption. A high resolution temperature output  
allows the implementation in depth measurement systems and  
thermometer function without any additional sensor. The  
MS5837-30BA can be interfaced to  
virtually  
any  
microcontroller. The communication protocol is simple, without  
the need of programming internal registers in the device. The  
gel protection and antimagnetic stainless steel cap make the  
module water resistant. This new sensor module generation is  
based on leading MEMS technology and latest benefits from  
MEAS Switzerland proven experience and know-how in high  
volume manufacturing, which has been widely used for over a  
decade.  
03/12/2015  
1
SENSOR SOLUTIONS /// MS5837-30BA  
MS5837-30BA  
Ultra Small Gel Filled Pressure Sensor  
PERFORMANCE SPECIFICATIONS  
ABSOLUTE MAXIMUM RATINGS  
Parameter  
Symbol Conditions  
Min.  
-0.3  
-40  
Typ.  
Max  
+4  
Unit  
V
Supply voltage  
Storage temperature  
Overpressure  
VDD  
TS  
+85  
50  
°C  
Pmax  
ISO 22810  
40 sec max  
Bar  
Maximum Soldering  
Temperature  
Tmax  
250  
+2  
°C  
Human Body  
Model  
ESD rating  
Latch up  
-2  
kV  
JEDEC standard  
No 78  
-100  
+100  
mA  
ELECTRICAL CHARACTERISTICS  
Parameter  
Operating Supply voltage  
Operating Temperature  
Symbol Conditions  
VDD  
T
Min.  
1.5  
Typ.  
3.0  
Max  
3.6  
Unit  
V
-20  
+25  
+85  
°C  
8192  
20.09  
10.05  
5.02  
2.51  
1.26  
0.63  
4096  
2048  
1024  
512  
Supply current  
(1 sample per sec.)  
IDD  
OSR  
µA  
256  
Peak supplycurrent  
Standby supplycurrent  
VDD Capacitor  
during conversion  
at 25°C  
1.25  
0.01  
470  
mA  
µA  
nF  
0.1  
From VDD to GND  
100  
ANALOG DIGITAL CONVERTER (ADC)  
Parameter  
Symbol Conditions  
Min.  
Typ.  
Max  
Unit  
Output Word  
24  
Bit  
8192  
4096  
14.8  
7.40  
3.72  
1.88  
0.95  
0.48  
16.44  
8.22  
4.13  
2.08  
1.06  
0.54  
18.08  
9.04  
4.54  
2.28  
1.17  
0.60  
2048  
Conversion time (1)  
tc  
OSR  
1024  
ms  
512  
256  
(1): Maximum values must be applied to determine w aiting times in I2C communication  
03/12/2015  
2
SENSOR SOLUTIONS /// MS5837-30BA  
MS5837-30BA  
Ultra Small Gel Filled Pressure Sensor  
PERFORMANCE SPECIFICATIONS (CONTINUED)  
PRESSURE OUTPUT CHARACTERISTICS (VDD = 3 V, T = 25°C UNLESS OTHERWISE NOTED)  
Parameter  
Conditions  
Min.  
Typ.  
Max  
Unit  
Operating Pressure Range  
Prange  
Full Accuracy  
0
30  
Bar  
0 … 6 bar  
0 … 20 bar  
0 … 30 bar  
-50  
-100  
-200  
+50  
+100  
+200  
Absolute Accuracy (1),  
Temperature range: 0 … 40°C  
mbar  
mbar  
0 … 6 bar  
0 … 20 bar  
0 … 30 bar  
-100  
-200  
-400  
+100  
+200  
+400  
Absolute Accuracy (1),  
Temperature range:-20 … 85°C  
Maximum error with supply  
voltage (2)  
Long-term stability  
VDD = 1.5 V … 3.6 V  
±30  
±30  
mbar  
mbar/year  
8192  
4096  
2048  
1024  
512  
0.20  
0.28  
0.38  
0.54  
0.84  
1.57  
Resolution RMS  
OSR  
mbar  
256  
IPC/JEDEC J-STD-020D.1  
(See application note AN808  
on http://meas-spec.com)  
Reflow soldering impact  
-8  
7
mbar  
Days  
Recovering time after reflow (3)  
(1) With autozero at one pressure point  
(2) With autozero at 3V point  
(3) Time to recover at least 66% of the reflow impact.  
TEMPERATURE OUTPUT CHARACTERISTICS (VDD = 3 V, T = 25°C UNLESS OTHERWISE NOTED)  
Parameter  
Conditions  
Min.  
Typ.  
Max  
Unit  
0 …10 bar, 25°C  
-1.5  
+1.5  
0 …10 bar, 0..60°C  
-20..85°C  
-2.0  
-4.0  
+2.0  
+4.0  
Absolute Accuracy  
°C  
Maximum error with supply  
voltage  
VDD = 1.5 V … 3.6 V  
± 0.3  
°C  
°C  
8192  
4096  
2048  
1024  
512  
0.0022  
0.0026  
0.0033  
0.0041  
0.0055  
0.0086  
Resolution RMS  
OSR  
256  
03/12/2015  
3
SENSOR SOLUTIONS /// MS5837-30BA  
MS5837-30BA  
Ultra Small Gel Filled Pressure Sensor  
PERFORMANCE SPECIFICATIONS (CONTINUED)  
DIGITAL INPUTS (SCL, SDA)  
Parameter  
Symbol  
Conditions  
Min.  
Typ.  
Typ.  
Max  
400  
Unit  
kHz  
V
Serial data clock  
Input high voltage  
Input low voltage  
Input leakage current  
SCL  
V
IH  
80% VDD  
0% VDD  
100% VDD  
20% VDD  
0.1  
V
IL  
V
Ileak25°C  
at 25°c  
µA  
DIGITAL OUTPUTS (SDA)  
Parameter  
Symbol  
Conditions  
Min.  
Max  
Unit  
Output high voltage  
VOH  
Isource = 0.6 mA  
80% VDD  
100% VDD  
V
Output low voltage  
VOL  
Isink = 0.6 mA  
0% VDD  
20% VDD  
V
03/12/2015  
4
SENSOR SOLUTIONS /// MS5837-30BA  
MS5837-30BA  
Ultra Small Gel Filled Pressure Sensor  
PERFORMANCE CHARACTERISTICS  
PRESSURE ERROR VS PRESSURE AND TEMPERATURE  
TEMPERATURE ERROR VS PRESSURE AND TEMPERATURE  
PRESSURE AND TEMPERATURE ERROR VS POWER SUPPLY  
03/12/2015  
5
SENSOR SOLUTIONS /// MS5837-30BA  
MS5837-30BA  
Ultra Small Gel Filled Pressure Sensor  
FUNCTIONAL DESCRIPTION  
GENERAL  
The MS5837-30BA consists of a piezo-resistive sensor and a sensor interface IC. The main function of the  
MS5837-30BA is to convert the uncompensated analogue output voltage from the piezo-resistive pressure sensor  
to a 24-bit digital value, as well as providing a 24-bit digital value for the temperature of the sensor.  
FACTORY CALIBRATION  
Every module is individually factory calibrated at two temperatures and two pressures. As a result, 6 coefficients  
necessary to compensate for process variations and temperature variations are calculated and stored in the 112-  
bit PROM of each module. These bits (partitioned into 6 coefficients W1 to W6) must be read by the  
microcontroller software and used in the program converting D1 and D2 into compensated pressure and  
temperature values.  
The coefficients W0 is for factory configuration and CRC.  
SERIAL I2C INTERFACE  
The external microcontroller clocks in the data through the input SCL (Serial CLock) and SDA (Serial DAta). The  
sensor responds on the same pin SDA which is bidirectional for the I2C bus interface. So this interface type uses  
only 2 signal lines and does not require a chip select.  
Module ref  
Mode  
I2C  
Pins used  
MS5837-30BA  
SDA, SCL  
03/12/2015  
6
SENSOR SOLUTIONS /// MS5837-30BA  
MS5837-30BA  
Ultra Small Gel Filled Pressure Sensor  
PRESSURE AND TEMPERATURE CALCULATION  
Start  
Maximum values for calculation results:  
PMIN = 0 bar PMAX = 30 bar  
TMIN = -20°C TMAX = 85°C TREF = 20°C  
Read calibration data (factory calibrated) from PROM  
Size[1]  
[bit]  
Value  
Recommended  
variable type  
Example /  
Typical  
Description | Equation  
Variable  
min  
0
max  
Pressure sensitivity | SENST1  
C1  
C2  
C3  
C4  
C5  
C6  
unsigned int 16  
unsigned int 16  
unsigned int 16  
unsigned int 16  
unsigned int 16  
16  
16  
16  
16  
16  
16  
65535  
65535  
65535  
65535  
65535  
65535  
34982  
36352  
20328  
22354  
26646  
26146  
Pressure offset | OFF  
0
T1  
Temperature coefficient of pressure sensitivity | TCS  
Temperature coefficient of pressure offset | TCO  
Reference temperature | TREF  
0
0
0
Temperature coefficient of the temperature | TEMPSENS unsigned int 16  
0
Readdigitalpressureandtemperaturedata  
D1  
D2  
Digital pressure value  
unsigned int 32  
unsigned int 32  
24  
24  
0
0
16777215  
16777215  
4958179  
6815414  
Digital temperature value  
Calculate temperature  
[2]  
Difference between actual and reference temperatre  
dT  
signed int 32  
signed int 32  
25  
41  
-16776960  
-4000  
16777215  
8500  
-5962  
dT = D2 - T = D2 - C5 * 28  
REF  
1981  
Actual temperature (-40…85°C with 0.01°C resolution)  
TEMP 20°C+dTTEMPSENS 200+dT C6 23  
TEMP  
= 19.81 °C  
Calculate temperature compensated pressure  
Offset at actual temperatur[3]  
OFF  
signed int 64  
signed int 64  
41  
41  
-17179344900  
-8589672450  
25769410560  
12884705280  
2381326464  
1145816755  
OFF =OFFT1 + TCO*dT =C2 *216 + (C4* dT)/27  
Sensitivity at actual temperatu[4]  
SENS  
SENS =SENS T1+TCS*dT=C1 * 215 + (C3 *dT )/28  
Temperature compensated pressure (0…30 bar with  
39998  
P
0.25mbar resolution)  
signed int 32  
58  
0
300000  
13  
P = D1 * SENS - OFF =(D1 * SENS / 2-1 OFF) / 2  
= 3999.8 mbar  
Display pressure and temperature value  
Notes  
[1]  
Maximal size of intermediate result during evaluation of variable  
[2]  
[3]  
[4]  
m
min and max have to be defined  
min and max have to be defined  
Flow chart for pressure and temperature reading and software compensation.  
03/12/2015  
7
SENSOR SOLUTIONS /// MS5837-30BA  
MS5837-30BA  
Ultra Small Gel Filled Pressure Sensor  
SECOND ORDER TEMPERATURE COMPENSATION  
Pressure and Temperature parameters values first order:  
OFF, SENS and TEMP  
Yes  
No  
(TEMP/ 100)< 20°C  
Low temperature  
High temperature  
Ti = 3 dT2 / 233  
OFFi = 3 (TEMP 2000)2 / 21  
SENSi = 5 (TEMP 2000)2 / 23  
Ti = 2 dT2 / 237  
OFFi = 1 (TEMP 2000)2 / 24  
SENSi = 0  
No  
Yes  
(TEMP/ 100) < -15°C  
Very low temperature  
OFFi = OFFi + 7 (TEMP + 1500)2  
SENSi = SENSi + 4 (TEMP + 1500)2  
Calculate pressure and temperature 2nd order  
OFF2 = OFF - OFFi  
SENS2 = SENS - SENSi  
TEMP2 = (TEMP Ti) / 100  
P2 = ((( D1 SENS2 ) / 221 OFF2) / 213) / 10  
[°C]  
[mbar]  
Flow chart for pressure and temperature to the optimum accuracy.  
03/12/2015  
8
SENSOR SOLUTIONS /// MS5837-30BA  
MS5837-30BA  
Ultra Small Gel Filled Pressure Sensor  
I2C INTERFACE  
COMMANDS  
The MS5837-30BA has only five basic commands:  
1. Reset  
2. Read PROM (112 bit of calibration words)  
3. D1 conversion  
4. D2 conversion  
5. Read ADC result (24 bit pressure / temperature)  
Each I2C communication message starts with the start condition and it is ended with the stop condition. The  
MS5837-30BA address is 1110110x (write: x=0, read: x=1).  
Size of each command is 1 byte (8 bits) as described in the table below. After ADC read commands, the device  
will return 24 bit result and after the PROM read 16 bit results. The address of the PROM is embedded inside of  
the PROM read command using the a2, a1 and a0 bits.  
Command byte  
hex value  
Bit number  
Bit name  
0
1
2
-
3
4
5
6
7
PRO CO  
M
Typ Ad2/ Ad1/ Ad0/ Stop  
Os2 Os1 Os0  
NV  
Command  
Reset  
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
1
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
0
0
0
0
0
0
1
1
1
1
1
1
0
0
1
0
0
0
0
1
1
0
0
0
0
1
1
0
1
0
0
1
1
0
0
0
0
1
1
0
0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0x1E  
0x40  
0x42  
0x44  
0x46  
0x48  
0x4A  
0x50  
Convert D1 (OSR=256)  
Convert D1 (OSR=512)  
Convert D1 (OSR=1024)  
Convert D1 (OSR=2048)  
Convert D1 (OSR=4096)  
Convert D1 (OSR=8192)  
Convert D2 (OSR=256)  
Convert D2 (OSR=512)  
Convert D2 (OSR=1024)  
Convert D2 (OSR=2048)  
Convert D2 (OSR=4096)  
Convert D2 (OSR=8192)  
ADC Read  
0x52  
0x54  
0x56  
0x58  
0x5A  
0x00  
0xA0 to  
0xAE  
PROM Read  
Ad2 Ad1 Ad0  
Command structure  
03/12/2015  
9
SENSOR SOLUTIONS /// MS5837-30BA  
MS5837-30BA  
Ultra Small Gel Filled Pressure Sensor  
RESET SEQUENCE  
The Reset sequence shall be sent once after power-on to make sure that the calibration PROM gets loaded into  
the internal register. It can be also used to reset the device PROM from an unknown condition.  
The reset can be sent at any time. In the event that there is not a successful power on reset this may be caused  
by the SDA being blocked by the module in the acknowledge state. The only way to get the MS5837-30BA to  
function is to send several SCLs followed by a reset sequence or to repeat power on reset.  
1
1
1
0
1
1
0
0
0
A
0
0
0
1
1
1
1
0
0
A
Device Address  
Device Address  
command  
cmd byte  
S
W
P
From Master  
From Slave  
S = Start Condition  
P = Stop Condition  
W = Write  
R = Read  
A = Acknowledge  
N = Not Acknowledge  
I2C Reset Command  
PROM READ SEQUENCE  
The read command for PROM shall be executed once after reset by the user to read the content of the calibration  
PROM and to calculate the calibration coefficients. There are in total 7 addresses resulting in a total memory of  
112 bit. Addresses contain factory data and the setup, calibration coefficients, the serial code and CRC. The  
command sequence is 8 bits long with a 16 bit result which is clocked with the MSB first. The PROM Read  
command consists of two parts. First command sets up the system into PROM read mode. The second part gets  
the data from the system.  
1
1
1
0
1
1
0
0
0
A
1
0
1
0
0
1
1
0
0
A
Device Address  
Device Address  
command  
cmd byte  
S
W
P
From Master  
From Slave  
S = Start Condition  
P = Stop Condition  
W = Write  
R = Read  
A = Acknowledge  
N = Not Acknowledge  
I2C Command to read memory address= 011  
1
1
1
0
1
1
0
1
0
A
X
X
X
X
X
X
X
X
0
A
X
X
X
X
X
X
X
X
0
Device Address  
Device Address  
data  
Memory bit 15 - 8  
data  
Memory bit 7 - 0  
S
R
N P  
From Master  
From Slave  
S = Start Condition  
P = Stop Condition  
W = Write  
R = Read  
A = Acknowledge  
N = Not Acknowledage  
I2C answer from MS5837-30BA  
03/12/2015  
10  
SENSOR SOLUTIONS /// MS5837-30BA  
MS5837-30BA  
Ultra Small Gel Filled Pressure Sensor  
CONVERSION SEQUENCE  
The conversion command is used to initiate uncompensated pressure (D1) or uncompensated temperature (D2)  
conversion. After the conversion, using ADC read command the result is clocked out with the MSB first. If the  
conversion is not executed before the ADC read command, or the ADC read command is repeated, it will give 0  
as the output result. If the ADC read command is sent during conversion the result will be 0, the conversion will  
not stop and the final result will be wrong. Conversion sequence sent during the already started conversion  
process will yield incorrect result as well. A conversion can be started by sending the command to MS5837-30BA.  
When command is sent to the system it stays busy until conversion is done. When conversion is finished the data  
can be accessed by sending a Read command, when acknowledge is sent from the MS5837-30BA, 24 SCL  
cycles may be sent to receive all result bits. Every 8 bits the system waits for an acknowledge signal.  
1
1
1
0
1
1
0
0
0
A
0
1
0
0
1
0
0
0
0
A
Device Address  
Device Address  
command  
cmd byte  
S
W
P
From Master  
From Slave  
S = Start Condition  
P = Stop Condition  
W = Write  
R = Read  
A = Acknowledge  
N = Not Acknowledge  
I2C command to initiate a pressure conversion (OSR=4096, typ=D1)  
1
1
1
0
1
1
0
0
0
A
0
0
0
0
0
0
0
0
0
A
Device Address  
Device Address  
command  
cmd byte  
S
W
P
From Master  
From Slave  
S = Start Condition  
P = Stop Condition  
W = Write  
R = Read  
A = Acknowledge  
N = Not Acknowledge  
I2C ADC read sequence  
1
1
1
0
1
1
0
1
0
X
X
X
X
X
X
X
X
0
X
X
X
X
X
X
X
X
0
X
X
X
X
X
X
X
X
0
Device Address  
Device Address  
data  
Data 23-16  
data  
Data 15 - 8  
data  
Data 7 - 0  
S
R
A
A
A
N
P
From Master  
From Slave  
S = Start Condition  
P = Stop Condition  
W = Write  
R = Read  
A = Acknowledge  
N = Not Acknowledge  
I2C answer from MS5837-30BA  
03/12/2015  
11  
SENSOR SOLUTIONS /// MS5837-30BA  
MS5837-30BA  
Ultra Small Gel Filled Pressure Sensor  
CYCLIC REDUNDANCY CHECK (CRC)  
MS5837-30BA contains a PROM memory with 112-Bit. A 4-bit CRC has been implemented to check the data  
validity in memory. The besides C code describes in detail CRC-4 calculation.  
D
B
1
D
B
1
D
B
1
D
B
1
D
B
1
D
B
1
C6  
D
B
9
D
B
8
D
B
7
D
B
6
D
B
5
D
B
4
D
B
3
D
B
2
D
B
1
D
B
0
5
4
3
2
1
0
0
1
2
3
4
5
6
CRC  
Factory defined  
C1  
C2  
C3  
C4  
C5  
Memory PROM mapping  
C Code example for CRC-4 calculation:  
unsigned char crc4(unsigned int n_prom[])  
// n_prom defined as 8x unsigned int (n_prom[8])  
{
int cnt;  
unsigned int n_rem=0;  
// simple counter  
// crc remainder  
unsigned char n_bit;  
n_prom[0]=((n_prom[0]) & 0x0FFF);  
n_prom[7]=0;  
for (cnt =0; cnt < 16; cnt++)  
{
// CRC byte is replaced by 0  
// Subsidiary value, set to 0  
// operation is performed on bytes  
// choose LSBor MSB  
if (cnt%2==1)  
else  
n_rem ^= (unsigned short) ((n_prom[cnt>>1]) &0x00FF);  
n_rem ^= (unsigned short) (n_prom[cnt>>1]>>8);  
for (n_bit = 8; n_bit > 0; n_bit--)  
{
if (n_rem & (0x8000))  
else  
}
n_rem = (n_rem << 1) ^ 0x3000;  
n_rem = (n_rem << 1);  
}
n_rem= ((n_rem >> 12) & 0x000F);  
return (n_rem ^ 0x00);  
// final4-bit remainder is CRC code  
}
03/12/2015  
12  
SENSOR SOLUTIONS /// MS5837-30BA  
MS5837-30BA  
Ultra Small Gel Filled Pressure Sensor  
APPLICATION CIRCUIT  
The MS5837 is a circuit that can be used in conjunction with a microcontroller in mobile altimeter applications.  
Typical application circuit  
PIN CONFIGURATION AND DEVICE PACKAGE OUTLINE  
UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN MILLIMETERS. GENERAL TOLERANCE ± 0.1  
1 GND  
2 VDD  
3 SCL  
GROUND  
POSITIVESUPPLY  
I2C CLOCK  
4 SDA  
I2C DATA  
Package outlines and Pin configuration  
03/12/2015  
13  
SENSOR SOLUTIONS /// MS5837-30BA  
MS5837-30BA  
Ultra Small Gel Filled Pressure Sensor  
RECOMMENDED PAD LAYOUT  
Pad layout for bottom side of the MS5837-30BA soldered onto printed circuit board.  
Recommended PCB footprint  
SHIPPING PACKAGE  
03/12/2015  
14  
SENSOR SOLUTIONS /// MS5837-30BA  
MS5837-30BA  
Ultra Small Gel Filled Pressure Sensor  
MOUNTING AND ASSEMBLY CONSIDERATIONS  
SOLDERING  
Please refer to the application note AN808 available on our website for all soldering recommendations.  
MOUNTING  
The MS5837-30BA can be placed with automatic Pick & Place equipment using vacuum nozzles. It will not be  
damaged by the vacuum. Due to the low stress assembly the sensor does not show pressure hysteresis effects. It  
is important to solder all contact pads.  
CONNECTION TO PCB  
The package outline of the module allows the use of a flexible PCB for interconnection. This can b e important for  
applications in watches and other special devices.  
SEALING WITH O-RINGS  
In applications such as outdoor watches the electronics must be protected against direct water or humidity. For  
such applications the MS5837-30BA provides the possibility to seal with an O-ring. The O-ring shall be placed at  
the groove location, i.e. the small outer diameter of the metal lid. The following O-ring / housing dimensions are  
recommended:  
O-ring inner diameter  
O-ring cross-section diameter  
Housing bore diameter  
1.8 ± 0.05 mm  
0.8 ± 0.03 mm  
3.07 ± 0.03 mm  
Please refer to the application note AN523 available on our website for O-ring mounting recommendations.  
CLEANING  
The MS5837-30BA has been manufactured under clean-room conditions. It is therefore recommended to  
assemble the sensor under class 10’000 or better conditions. Should this not be possible, it is recommended to  
protect the sensor opening during assembly from entering particles and dust. To avoid cleaning of the PCB,  
solder paste of type “no-clean” shall be used. Warning: cleaning might damage the sensor.  
ESD PRECAUTIONS  
The electrical contact pads are protected against ESD up to 2 kV HBM (human body model). It is therefore  
essential to ground machines and personnel properly during assembly and handling of the device. The MS5837-  
30BA is shipped in antistatic transport boxes. Any test adapters or production transport boxes used during the  
assembly of the sensor shall be of an equivalent antistatic material.  
DECOUPLING CAPACITOR  
Particular care must be taken when connecting the device to the power supply. A minimum of 100nF ceramic  
capacitor must be placed as close as possible to the MS5837-30BA VDD pin. This capacitor will stabilize the  
power supply during data conversion and thus, provide the highest possible accuracy.  
03/12/2015  
15  
SENSOR SOLUTIONS /// MS5837-30BA  
MS5837-30BA  
Ultra Small Gel Filled Pressure Sensor  
ORDERING INFORMATION  
Part Number / Art. Number Product  
Delivery Form  
MS583730BA01-50  
MS5837-30BAUltra Small Gel Filled Pressure Sensor  
Tape & Reel  
CDOC-DA-0093  
7
03/12/2015  
16  
SENSOR SOLUTIONS /// MS5837-30BA  

相关型号:

MS590PNB

High Reliability Power Inductors
COILCRAFT

MS590PNB102NLC

General Purpose Inductor, 1uH, 30%, 1 Element, Ferrite-Core, SMD
COILCRAFT

MS590PNB102NLN

General Purpose Inductor, 1uH, 30%, 1 Element, Ferrite-Core, SMD
COILCRAFT

MS590PNB102NSZ

High Reliability Power Inductors
COILCRAFT

MS590PNB103MLC

General Purpose Inductor, 10uH, 20%, 1 Element, Ferrite-Core, SMD
COILCRAFT

MS590PNB103MLN

General Purpose Inductor, 10uH, 20%, 1 Element, Ferrite-Core, SMD
COILCRAFT

MS590PNB103MLW

General Purpose Inductor, 10uH, 20%, 1 Element, Ferrite-Core, SMD
COILCRAFT

MS590PNB103MSH

General Purpose Inductor, 10uH, 20%, 1 Element, Ferrite-Core, SMD, 4747, CHIP, 1212-60M
COILCRAFT

MS590PNB103MST

General Purpose Inductor,
COILCRAFT

MS590PNB103MSU

General Purpose Inductor,
COILCRAFT

MS590PNB103MSZ

High Reliability Power Inductors
COILCRAFT

MS590PNB104MLN

General Purpose Inductor, 100uH, 20%, 1 Element, Ferrite-Core, SMD
COILCRAFT