P40P42A12P1-120 [TE]
Definite Purpose Magnetic Contactor;型号: | P40P42A12P1-120 |
厂家: | TE CONNECTIVITY |
描述: | Definite Purpose Magnetic Contactor |
文件: | 总3页 (文件大小:97K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Catalog 1308242
Issued 3-03 (PDF Rev. 5-05)
P&B
P30/P40series
Definite Purpose Magnetic Contactor
30/40 Ampere Full Load
40/50 Ampere Resistive
AC & DC Coils
File E22575
File LR15734
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
DC Coil
AC Coil
Coil Data
Features
• AC and DC coils.
• Available with auxiliary switch.
• Variety of main contact terminals.
• For control of motors, power supplies, heating elements and lighting.
Nominal
VDC
Resistance
(Ohms 10% Operate*
@ 25° C)
Must
Maximum
Operating
Volts
Nominal Coil
Current (ma) @
Nominal Voltage
Volts
12
24
20.8
84
334
9
18
36
90
15
30
57
577
286
144
57
48
120
2,110
144
Contact Data @ 25°C
Arrangements: Up to 4 Form X (4PST-NO-DM)
Ratings: See contact rating table.
Material: Silver-cadmium oxide.
Expected Life: 200,000 operations at full load.
AC coil: 2 million operations, mechanical.
DC coil: 10 million operations, mechanical.
Minimum Contact Data: 3A @ 120VAC.
AC Voltage
Rating
Nominal
50/60 Hz.
Must Operate*
50/60 Hz.
24
24
20.4
94
177
236
120
240
277
110/120
208/240
277
Main Contact Ratings
Motor Rating in Amps, 3Ø3P or 1Ø2P
Resistive
Rating
@ 600V
40A
Tungsten
Rating
@277V
40A
*Applicable for vertical mounting, but not for upside-down mounting.
Type Full Load
@ 600V @ 240V
Locked Rotor
@480V
Note: Coil suppression is recommended for all DC coil units, particulary 120 and
@ 600V
240VDC coils.
P30
P40
30A
40A
180A
240A
150A
120A
200A
160A
50A
50A
Operate Data
Must-Operate Voltage: See coil data tables.
P30 Electrical Discharge Lamp Control: 40A @ 240V (Delta), 40A @ 600V (Wye).
P40 Electrical Discharge Lamp Control: 50A @ 600V (Wye).
Motor Rating in Horsepower
Type
@ 120V
@ 240V
@ 440-600V
P30
P40
1Ø2P
3Ø3P
1Ø2P
3Ø3P
1.5HP
3HP
2HP
5HP
3HP
7.5HP
5HP
—
7.5HP
—
Environmental Data
Temperature Range: –55°C to +65°C.
10HP
15HP
Auxiliary Snap-Action Switch
Arrangements: Up to 2 Form C (DPDT).
Rating: 10 amps at 120-250VAC @ 25°C.
Material: Silver.
Mechanical Data
Mounting: Universal mounting bracket. See outline drawings.
Termination:
Initial Dielectric Strength
Initial Breakdown Voltage: 2,200V rms minimum between all elements
Contacts: Binder screw, box lug, captive pressure plate, combination
screw and dual .250” (6.35mm) quick connect, or
combination box lug and dual .250” (6.35mm) quick
connect. See Main Contact Terminal Options photo.
Coil: Combination 8-32 screw and .250” (6.35mm) quick connect.
Aux. Switch: .187” (4.75mm) quick connect.
and between all elements to ground.
Coil Data @ 25°C
Voltage: From 12 to 120VDC, and 24 to 277VAC, 50/60 Hz.
Power: DC, 7.5 W; AC, 92VA, In rush; 12 VA Sealed.
Duty Cycle: Continuous.
Weight: 3 Pole Models: 25 oz. (709g) approximately.
4 Pole Models: 28 oz. (794g) approximately.
Insulation Class: Class A, standard, Class B available.
Initial Insulation Resistance: 100 megohms, minimum.
Dimensions are shown for
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
823
Catalog 1308242
Issued 3-03 (PDF Rev. 5-05)
P&B
Ordering Information
Typical Part No. B
P30
P
42
A
1
4
P
1
-240
1. Type:
P30 = Definite Purpose Contactor, 30 amp.
P40 = Definite Purpose Contactor, 40 amp.
2. Auxiliary Switch:
P = No Aux. Switch
C = 1 Form C (SPDT)
F = 2 Form C (DPDT)
3. Main Contact Arrangement:
42 = 3 Form X (3PST-NO-DM)
43 = 2 Form X (DPST-NO-DM)
& 1 Form Y (SPST-NC-DB)
47 = 4 Form X (4PST-NO-DM)
48 = 2 Form X (DPST-NO-DM)
& 2 Form Y (DPST-NC-DB)
49 = 4 Form Y (4PST-NC-DB)
45 = 1 Form X (SPST-NO-DB)
& 2 Form Y (DPST-NC-DB)
Other contact arrangements are available.
4. Coil Control Input:
A = Alternating Current, 50/60 Hz.
D = Direct Current
5. Mounting and Installed Accessories:
1 = Standard Mounting
6. Main Contact Terminals:
2 = Screw Terminals
5 = Captive Pressure Plate
6 = Box Lug & Dual .250” (6.35mm) Quick Connect
3 = Screw Terminals & Dual .250” (6.35mm) Quick Connect
4 = Box Lug
7. Auxiliary Contact Terminals:
P = No Auxiliary Switch
C = .187” (4.75mm) Quick Connect
8. Coil Terminals:
1 = Combination 8-32* Screw Terminal and .250” (6.35mm) Quick Connect
9. Coil Voltage:
24, 120, 240 or 277VAC
12, 24 or 120VDC
Our authorized distributors are more likely to maintain the following items in stock for immediate delivery.
P30P42A12P1-120
P30P42D12P1-24
P30P47A12P1-120
P30P47D12P1-24
P40P42A12P1-24
P40P42A12P1-120
P40P42A12P1-240
P40P42D12P1-24
Dimensions are shown for
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
824
Catalog 1308242
Issued 3-03 (PDF Rev. 5-05)
P&B
Outline Dimensions
3 Pole Models
AC Coil
DC Coil
3.25 MAX.
(82.55)
W/SWITCH
2.550
(64.77)
.25 TYP.
(6.4)
2.650 MAX.
.21 TYP.
(5.3)
3.420 MAX.
(86.87)
3.975 MAX.
(100.97)
(67.31)
W/O SWITCH
3.250 .010
(82.55 .25)
3.550 MAX.
(90.17)
3.800 MAX.
(96.52)
3.125 .010
(79.38 .25)
3.550 MAX.
(90.17)
.5 DIA.
(12.7)
1.500 .020
(38.10 .51)
2.00
(50.8)
4 Pole Models
AC Coil
DC Coil
3.600 MAX.
(91.44)
W/SWITCH
2.550
(64.77)
.25 TYP.
(8.4)
.21 TYP.
(5.3)
3.350 MAX.
3.975 MAX.
(100.97)
3.420 MAX.
(86.87)
(85.09)
W/O SWITCH
3.250 .010
(82.55 .25)
3.550 MAX.
(90.17)
3.125 .010
(79.38 .25)
3.550 MAX.
(90.17)
.5 DIA.
(12.7)
3.800 MAX.
(96.52)
1.500 .020
(38.10 .51)
2.00
(50.8)
Contact Terminal Options
Code 2
Code 3
Code 4
Code 5
Code 6
#10-32 UNF-2A X .500” (12.7mm)
Screw with Captive
#10-32 UNF-2A X .375” (9.525mm)
Binder Terminal Screw 15S365
accepts the following
Dual .250” (6.35mm)
Quick Connect 26A945
#10-32 UNF-2A X .375” (9.525mm)
Binder Terminal Screw 15S365
accepts the following
Pressure Plate 15S362
Box Lug (Keyed) 24C540 with
15S361 & 15S364 Screws
Accepts the following wire sizes:
Solid, Single —14-4 AWG
Dual .250” (6.35mm)
Quick Connect 26A945
Box Lug 9P30X3
Accepts the following wire sizes:
Solid, Single —22-8 AWG
Solid, Double —22-14 AWG
Stranded, Single —22-8 AWG
Stranded, Double —22-16 AWG
wire size: Solid, Single — 8 AWG
Accepts the following wire sizes:
Solid, Single —14-4 AWG
wire size: Solid, Single — 8 AWG
Main Contact Ordering and Replacement Information
Contact Replacement Kits
Contact replacement kits for 3 pole models include 3 contact pressure springs, 3 movable contact assemblies and 6 stationary contact assemblies. Kits for 4
pole models include 4 contact pressure springs, 4 movable contact assemblies and 8 stationary contact assemblies. Contact replacement kits are for use only
on those models with form X contact arrangements.
Kits for P30 contactors:
To Replace Contacts:
3 Form X models - Kit No. 9P30X1
4 Form X models - Kit No. 9P30X2
1. Remove screws holding dust cover in place, and remove cover.
2. Compress and remove contact pressure springs.
3. Lift movable contacts and remove.
Kits for P40 contactors:
4. Remove screws holding stationary contact in place, and remove contacts.
5. Reverse the above procedure to install new stationary and movable contacts.
Caution: Do not overtighten the screws, as it is possible to strip the threads.
3 Form X models - Kit No. 9P40X1
4 Form X models - Kit No. 9P40X2
Dimensions are shown for
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
825
Refer to inside back cover.
相关型号:
P40R154M1
Ceramic Capacitor, Multilayer, Ceramic, 100V, 20% +Tol, 20% -Tol, X7R, 15% TC, 0.15uF, Through Hole Mount, AXIAL LEADED
CDE
©2020 ICPDF网 联系我们和版权申明