SW-393SMB [TE]
GaAs SPST High Isolation Terminated Switch 0.5 - 2.0 GHz; 砷化镓SPST高隔离开关终止0.5 - 2.0 GHz的型号: | SW-393SMB |
厂家: | TE CONNECTIVITY |
描述: | GaAs SPST High Isolation Terminated Switch 0.5 - 2.0 GHz |
文件: | 总3页 (文件大小:129K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
GaAs SPST High Isolation Terminated Switch
0.5 - 2.0 GHz
SW-393
V4
Features
Functional Schematic
• Terminated RF Output
• High Isolation: 42 dB up to 2.0 GHz
•
•
•
Single Positive Control
CMOS Compatible Logic
SOIC-8 Plastic Package
Description
M/A-COM’s SW-393 is a GaAs monolithic SPST
terminated switch in a low cost SOIC 8-lead plastic
package. The SW-393 is ideally suited for use
where low power consumption and high isolation are
required.
Typical applications include PCS and GSM LO
Switching, switch matrices and switched filter banks
in systems such as radio and cellular equipment.
The SW-393 is fabricated using a mature 1-micron
gate length GaAs MESFET process. The process
features full chip passivation for increased
performance and reliability.
Pin Configuration 4
Pin No.
Function
GND
Pin No.
Function
GND
Ordering Information 1
1
2
3
4
5
6
7
8
RF1
CTL
Part Number
SW-393-PIN
SW-393TR
Package
GND
RF2
Bulk Packaging
1000 piece reel
Sample Board
GND
GND
4. Blocking capacitors are required on all RF ports. VS can be
applied at RF1 or RF2 using 10K or greater pull-up resistors.
SW-393SMB
1. Reference Application Note M513 for reel size information.
Truth Table 5,6,7
Absolute Maximum Ratings 2,3
Control
RF1 - RF2
Parameter
Input Power
Absolute Maximum
+34 dBm
0
1
Off
On
Operating Voltage (VS, VCTL
Operating Temperature
Storage Temperature
)
+8.5 Volts
-40°C to +85°C
-65°C to +150°C
5. “0” = 0 ± 0.2 VDC
6. “1” = +5 ± 0.2 VDC
7. Vs = +5 ± 0.2 VDC
2. Exceeding any one or combination of these limits may cause
permanent damage to this device.
3. M/A-COM does not recommend sustained operation near
these survivability limits.
1
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
GaAs SPST High Isolation Terminated Switch
0.5 - 2.0 GHz
SW-393
V4
Electrical Specifications8: TA = 25°C
Parameter
Test Conditions
Units
Min.
Typ.
Max.
Insertion Loss
0.5 - 2.0 GHz
dB
—
1.6
1.8
0.5 - 1.0 GHz
1.0 - 2.0 GHz
dB
dB
50
40
53
42
—
—
Isolation
VSWR
0.5 - 1.5 GHz
0.5 - 2.0 GHz
Ratio
Ratio
—
—
1.5:1
1.7:1
—
—
Input Power, +5 V Control/Supply
0.5 GHz
0.9 GHz
1.5 GHz
dBm
dBm
dBm
—
—
—
25
25
26
—
—
—
1 dB Compression
Trise, Tfall
Ton, Toff
10% to 90% RF, 90% to 10% RF
50% Control to 90% RF, Control to 10% RF
In-Band
µs
µs
—
—
—
2
2
—
—
—
Transients
mV
26
2-Tone, 5 MHz spacing, +10 dBm each
Input IP2
Input IP3
0.5 GHz
0.9 GHz
dBm
dBm
—
—
53
58
—
—
2-Tone, 5 MHz spacing, +10 dBm each
0.5 GHz
0.9 GHz
dBm
dBm
—
—
39
38
—
—
8. All measurements taken at 900 MHz in a 50 Ω system unless otherwise specified. Loss varies at 0.003 dB/°C.
SOIC-8†
†
Meets JEDEC moisture sensitivity level 1 requirements.
2
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
GaAs SPST High Isolation Terminated Switch
0.5 - 2.0 GHz
SW-393
V4
Typical Performance Curves
VSWR vs. Frequency
Insertion Loss vs. Frequency
4.5
3.0
2.8
4.0
Output Insertion Loss
-40°C
Output Isolation
Input
2.6
2.4
2.2
2.0
1.8
1.6
1.4
1.2
1.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0.0
+85°C
+25°C
0.5
1.0
1.5
2.0
2.5
3.0
0.5
1.0
1.5
2.0
2.5
3.0
Frequency (GHz)
Frequency (GHz)
Isolation vs. Frequency
Handling Procedures
60
50
40
30
Please observe the following precautions to avoid
damage:
Static Sensitivity
-40°C
+85°C
+25°C
20
10
0
Gallium Arsenide Integrated Circuits are sensitive
to electrostatic discharge (ESD) and can be
damaged by static electricity. Proper ESD control
techniques should be used when handling these
devices.
0.5
1.0
1.5
2.0
2.5
3.0
Frequency (GHz)
3
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
相关型号: