T92S7D12-12-00 [TE]

T92 Series Two-pole Power Relay;
T92S7D12-12-00
型号: T92S7D12-12-00
厂家: TE CONNECTIVITY    TE CONNECTIVITY
描述:

T92 Series Two-pole Power Relay

文件: 总5页 (文件大小:789K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
General Purpose  
High Power PCB Relays  
Potter & Brumfield  
T92 Series Two-pole Power Relay  
n
n
n
30/40/50A switching capability  
Designed to control compressor loads to 3.5 tons, 110LRA / 25.3FLA  
Meets requirements of UL 508 and UL 873 spacings - 8mm through  
air, 9.5mm over surface  
n
Meets requirements of VDE 8mm spacing, 4kV dielectric coil-to-  
contact  
n
n
n
n
n
Meets requirements of UL Class F construction  
UL approved for 600VAC switching (1.5HP)  
Screw terminal version (consult factory for availability, ratings)  
Anti-explosive version available (Meets EN 60079-15)  
WG version available (Meets EN 60335-1)  
Typical applications  
HVAC, residential / commercial appliances, industrial controls, charging  
Approvals  
Contact ratings 1) (T92 Type) (continued)  
UL E22575; CSA LR48471; VDE 40019600; TUV R 50083843 0008;  
TUV 15090924 002; TUV 15090883 001  
Technical data of approved types on request.  
Type  
AgSnOInO  
NO  
NO  
NO  
NO  
NO  
Load  
Cycles  
40A, 240VAC, resistive 85°C  
30A, 277VAC, resistive (DC coil only)  
30A, 277VAC, resistive (AC coil only)  
20A, 506VAC, resistive  
50x103  
250x103  
100x103  
100x103  
Contact Data  
Type  
Contact arrangement  
T92  
2 form A (NO)  
2 form C (CO)  
T92H  
2 form A (NO)  
1.5HP, 120VAC, 2 pole making/breaking (Fig.1) 100x103  
NO  
NO  
NO  
3HP, 240VAC, 3 phase (DC coil only)  
3HP, 480VAC, 3 phase (DC coil only)  
2HP, 600VAC, 3 phase (DC coil only)  
100x103  
100x103  
100x103  
Rated voltage  
Max. switching voltage  
Rated current  
Overload current*  
Contact material  
277VAC  
600VAC  
30A/40A NO; 3A NC  
60A NO; 4.5A NC  
Ag Alloy  
50A NO  
75A NO  
Special Ag Alloy X (Cd Free), wash tight  
NO  
NO  
NO  
30A, 250VAC, resistive  
30A, 400VAC, resistive  
20A, 480VAC, resistive  
100x103  
100x103  
100x103  
Min. recommended contact load  
500mA (NO), 12VAC or 5VDC  
100mA (NC), 12VAC or 5VDC  
360 cycles per hour  
VDE  
Frequency of operation, with load  
Operate/release time max.,  
including bounce  
AgCdO, flange mount relays  
NO  
NC  
CO  
20A, 400VAC  
3A, 400VAC  
20A NO / 3A NC, 400VAC  
100x103  
30x103  
30x103  
25/25ms  
< 100 mΩ at 6VDC 1A  
Initial contact resistance  
*Note: Minimum electrical endurance 50 cycles  
AgCdO, PC mount relays  
NO  
NC  
CO  
30A, 400VAC  
3A, 400VAC  
30A NO / 3A NC, 400VAC  
100x103  
30x103  
30x103  
Contact ratings1) (T92H Type)  
UL508  
Anti-explosion, sealed type  
NO  
50A, 277VAC, resistive, 85°C  
6x103  
NO  
30A 250VAC, 25°C  
100x103  
100x103  
Note: Coil voltage 12-48VDC covered in UL approval  
Anti-explosion, break device  
NO  
15A 480VAC  
ARI 780-86 Endurance Test (section 6.6):  
HVAC Definite Purpose Contactor Standard  
Normally Open Contacts  
Single Phase/Two Pole (Both poles together switching a single load)  
110 LRA, 25.3 FLA, 200K operations (DC Coil)  
Contact ratings 1) (T92 Type)  
Type  
UL508  
AgCdO  
NO  
NO  
NO  
Load  
Cycles  
40A, 277VAC, resistive  
30A, 277VAC, resistive (DC coil only)  
30A, 277VAC, resistive (AC coil only)  
10A, 600VAC, resistive  
1HP, 120VAC  
6x103  
250×103  
100×103  
250x103  
100x103  
1x103  
L1  
L2  
Figure 1  
T1  
T2  
NO  
NO  
Single Phase Per Pole (Single load per pole)  
110 LRA, 18 FLA, 200K operations (DC Coil).  
60 LRA, 14 FLA, 200K operations (AC Coil).  
NO  
NO  
NO  
NO  
NO  
NO  
3HP, 240VAC  
1.5HP, 480 or 600VAC  
110LRA/25.3FLA, 240VAC  
7.3A, 240VAC, pilot duty  
20A, 28VDC, resistive  
TV10, 120VAC  
100x103  
100x103  
100x103  
100x103  
25x103  
L1  
L2  
T1  
T2  
Figure 2  
NC  
NC  
NC  
3A, 277VAC  
2A, 480VAC, general purpose  
1A, 600VAC  
100x103  
100x103  
100x103  
1) Contact ratings at 25°C (unless otherwise noted) with relay properly vented.  
FLA, LRA ratings are compatible with 3.5 ton compressor applications.  
Mechanical endurance  
T92  
T92H  
10x106 ops.  
1x106 ops  
1
04-2021, Rev. 0421  
Catalog and product specification according  
to IEC 61810-1 and to be used only together  
with the ‘Definitions’ section.  
Catalog and product data is subject to the  
terms of the disclaimer and all chapters of  
the ‘Definitions’ section, available at  
http://relays.te.com/definitions  
Catalog product data, ‘Definitions’ section,  
application notes and all specifications are  
subject to change.  
www.te.com  
© 2012 Tyco Electronics Corporation,  
a TE Connectivity Ltd. company.  
General Purpose  
High Power PCB Relays  
Potter & Brumfield  
T92 Series Two-pole Power Relay (Continued)  
Coil Data  
Coil voltage range  
Coil Data (continued)  
5 to 110VDC; 12 to 240VAC  
120  
100  
80  
60  
40  
20  
0
Max. coil power  
Max. coil temperature  
Coil insulation system according UL  
1.7W; 4.0VA  
155°C  
Class F  
Coil versions, DC coil (D type)  
Coil  
code  
Rated  
voltage2)  
VDC  
5
Operate  
voltage3)  
VDC  
3.75  
4.5  
6.75  
9
13.5  
16.5  
18  
27  
36  
82.5  
90  
Release  
voltage  
VDC  
0.6  
0.6  
0.9  
1.2  
1.8  
2.2  
2.4  
3.6  
4.8  
11  
12  
Coil  
resistance  
Ω 10ꢀ  
14.9  
22  
48  
86  
197  
294  
350  
767  
1390  
7255  
8514  
Rated coil  
power  
W
5
6
6
90 95 100 105 110 115 120 125 130 135 140 145 150  
Applied Coil Voltage (% of Rated Nominal)  
70 75 80 85  
9
9
12  
18  
22  
24  
36  
48  
110  
120  
12  
18  
22  
24  
36  
48  
110  
120  
1.7W/  
Min. 0.41W  
hold  
Note: This chart only apply for T92 standard type. For coil data of T92 Anti-  
explosion sealed type and T92H type, please contact TE engineering.  
Insulation Data  
Initial dielectric strength  
2) For T92H type, after the energization time of 100ms with rated voltage, the coil  
requires a reduction of the coil voltage to 50ꢀ of rated voltage.  
3) For Anti-explosion sealed type, the operate voltage is 80ꢀ of the rated coil  
voltage.  
between open contacts  
between contact and coil  
between adjacent contact  
Initial surge withstand voltage  
between contact and coil  
Initial insulation resistance (@500VDC)  
between insulated elements  
Clearance/creepage  
1500Vrms  
4000Vrms  
2000Vrms  
8kV  
Coil versions, AC coil (A type)  
Coil  
Rated Frequency Operate  
Release  
Coil  
Rated coil  
1x109Ω  
code voltage  
VAC  
voltage  
VAC, 60Hz VAC, 60Hz Ω 10ꢀ  
voltage resistance power  
Hz  
60  
60  
60  
50/60  
60  
VA  
4
4
4
4
4
4
4
between contact and coil  
8mm clearance/9.5mm creepage  
12  
24  
110  
120  
208  
240  
277  
12  
24  
110  
9.6  
19.2  
88  
1.2  
2.4  
11  
9.1  
36.6  
793  
Other Data  
110/120  
208  
96  
12  
950  
Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content  
refer to the Product Compliance Support Center at  
www.te.com/customersupport/rohssupportcenter  
Ambient temperature  
166.4  
192  
221.6  
20.8  
24  
27.7  
2841  
3800  
5485  
220/240  
250/277  
50/60  
50/60  
Coil versions, AC coil (F type)  
Coil Rated Frequency Operate  
DC coil  
AC coil  
-55ºC to 85ºC  
-55ºC to 65ºC  
Release  
Coil  
Rated coil  
code voltage  
VAC  
voltage  
VAC, 60Hz VAC, 60Hz Ω 10ꢀ  
voltage resistance power  
Category of environmental protection  
IEC 61810  
Hz  
50  
50  
50  
50  
VA  
3.5  
3.5  
3.5  
3.5  
RTI - dust protected,  
RTII - flux proof, RTIII - wash tight  
1.65mm max amplitude, 10-55 Hz  
10G for 11msec  
12  
24  
48  
12  
24  
48  
9.6  
19.2  
38.4  
192  
1.2  
2.4  
4.8  
24  
11.2  
44.4  
179.2  
4355  
Vibration resistance (functional)  
Shock resistance (functional)  
Shock resistance (destructive)  
Terminal type  
240  
240  
100G  
All figures are given for coil without preenergization, at ambient temperature +23°C.  
For A type, 110V/120V, 50/60Hz. Signify 50Hz Operation at Nominal 110V, 60 Hz  
Operation at Nominal 120V.  
PCB / Quick Connect / Screw  
2
04-2021, Rev. 0421  
Catalog and product specification according  
to IEC 61810-1 and to be used only together  
with the ‘Definitions’ section.  
Catalog and product data is subject to the  
terms of the disclaimer and all chapters of  
the ‘Definitions’ section, available at  
http://relays.te.com/definitions  
Catalog product data, ‘Definitions’ section,  
application notes and all specifications are  
subject to change.  
www.te.com  
© 2012 Tyco Electronics Corporation,  
a TE Connectivity Ltd. company.  
General Purpose  
High Power PCB Relays  
Potter & Brumfield  
T92 Series Two-pole Power Relay (Continued)  
Dimensions  
T92/T92H – Mounting and termination code 1  
T92 – Mounting and termination code 2, 3 and 4  
1.ꢀ6 MAX.  
(ꢀ4.54)  
2.700 MAX.  
(68.58)  
2.06 MAX.  
(52.32)  
1.36 MAX.  
(34.54)  
1.04 MAX.  
(26.42)  
1.495 MAX.  
(ꢀ7.97)  
1.21 MAX.  
(30.73)  
.156 0.012  
(3.96 0.3)  
.250 TYP.  
(6.35)  
1.618 .020  
.047 TYP.  
(1.19)  
(41.10 .51)  
2.05 MAX.  
(52.07)  
.585 .005  
(14.86 .13)  
.032 TYP.  
(0.81)  
.309 .005  
(7.85 .13)  
2.ꢀ45 .005  
(59.56 .1ꢀ)  
Pre-soldering  
1.618 TYP.  
(41.10 .51)  
in below side  
.585 .005  
(14.86 .1ꢀ)  
.ꢀ09 .005  
(7.85 .1ꢀ)  
1.000 .010  
(25.40 .25)  
.630 .005  
(16.00 .13)  
.090 RAD.  
(2.29)  
FOR #8 SCREW  
.6ꢀ0 TYP.  
(16.00)  
Note: Dimensions of the pins after tin soldering  
a) +0.3mm for the width and the thickness  
b) +1.0mm for the length  
T92 – Mounting and termination code 5  
PCB layout  
Bottom view on pins  
2.700 MAX.  
(68.58)  
T92/T92H - Mounting and termination code 1  
1.36 MAX.  
(34.54)  
.090 (2.29)  
RAD. FOR  
#8 SCREW  
1.618  
(41.10)  
.585  
(14.86)  
.309  
.185  
(4.70)  
(7.85)  
2.345 .005  
(59.56 .13)  
.365  
(9.27)  
1.431 MAX.  
(36.34)  
2.135 MAX.  
(54.23)  
.630  
(16.00)  
1.000  
(25.40)  
2.010 MAX.  
(51.05)  
.203 TYP.  
(5.16)  
.052 TYP.  
(1.32)  
.072 TYP.  
(1.83)  
.913 MAX.  
(23.19)  
.162  
(4.12)  
An alternate PC board layout utilizes .076 .003 (1.93 .076) diameter holes on the same  
center-to-center spacing shown above. Use of the rectangular holes is recommended for  
improved solderability.  
Terminal assignment  
Bottom view on pins  
Only necessary terminals are present on single throw models. Consequently, some holes  
will be unnecessary for single throw models.  
2 form A  
2 form C  
0
1
0
1
2
6
4
8
2
6
4
3
7
8
3
04-2021, Rev. 0421  
www.te.com  
© 2012 Tyco Electronics Corporation,  
a TE Connectivity Ltd. company.  
Catalog and product specification according  
to IEC 61810-1 and to be used only together  
with the ‘Definitions’ section.  
Catalog and product data is subject to the  
terms of the disclaimer and all chapters of  
the ‘Definitions’ section, available at  
http://relays.te.com/definitions  
Catalog product data, ‘Definitions’ section,  
application notes and all specifications are  
subject to change.  
Potter & Brumfield  
T92 Series Two-pole Power Relay (Continued)  
Product code structure (T92H type)  
Type  
Typical product code T92H  
P
7
D
1
X
-12  
T92H Power relay T92 High Performance (50A)  
Enclosure  
P
S
Dust protected plastic case  
Wash-tight, tape sealed, plastic case (Mounting and termination code 1)  
Contact arrangement  
7
Coil Input  
D
2 form A (2 NO)  
DC voltage  
Mounting and termination  
1
Printed circuit board mount; printed circuit board terminals.  
Contact material  
X
Special Ag Alloy X (Cd Free)  
Coil voltage  
Coil code: please refer to coil versions table  
Product code  
T92HP7D1X-12  
T92HP7D1X-24  
T92HP7D1X-48  
Enclosure  
Contacts  
Coil  
Mounting  
Contact Material  
Coil  
Part number  
6-1423008-6  
6-1423008-7  
6-1423008-9  
Plastic dust cover 2 form A, 2 NO  
DC  
PCB terminals  
Special Ag Alloy X (Cd Free)  
12VDC  
24VDC  
48VDC  
Note. This list represents the most common types and does not show all variants covered by this datasheet, other types on request.  
Product code structure (T92 type)  
Product code structure  
Type  
Typical product code T92  
S
11  
D
2
2
-24 -99  
T92  
Printed circuit board / panel mount power relay T92  
Enclosure  
P
S
Dust protected plastic case  
Wash-tight, tape sealed, plastic case (Mounting and termination code 1)  
Wash-tight, glue sealed, plastic case (Mounting and termination code 1, 2 for anti-explosion version)  
Top sealed, not wash-tight, not tape sealed on bottom (Mounting and termination codes 2, 3 & 4)  
Contact arrangement  
7
Coil Input  
A
2 form A (2 NO)  
11 2 form C (2 CO)  
AC voltage, 60Hz or 50/60 Hz (consult coil versions table)  
D
DC voltage  
F AC voltage, 50Hz  
Mounting and termination  
1
2
3
4
5
Printed circuit board mount; printed circuit board terminals.  
Panel mount via flanged cover; .250” (6.35mm) x .032” (.81mm) QC terminal  
Panel mount via flanged cover; .187” (4.75mm) x .032” (.81mm) QC terminals for coil and .250” (6.35mm) for contacts  
Panel mount via flanged cover, .187” (4.75mm) x .020” (.51mm) QC terminals for coil and .250” (6.35mm) for contacts.  
Panel mount via flanged cover, M4 screws w/ captive pressure plates. Requires Enclosure P and Contact arrangement 7.  
Contact material  
2
AgCdO  
4
AgSnOInO  
X
Special Ag Alloy X (Cd Free)  
Coil voltage  
Coil code: please refer to coil versions table  
Customer code  
-99  
Anti-explosion  
-00  
WG version  
4
04-2021, Rev. 0421  
Catalog and product specification according  
to IEC 61810-1 and to be used only together  
with the ‘Definitions’ section.  
Catalog and product data is subject to the  
terms of the disclaimer and all chapters of  
the ‘Definitions’ section, available at  
http://relays.te.com/definitions  
Catalog product data, ‘Definitions’ section,  
application notes and all specifications are  
subject to change.  
www.te.com  
© 2012 Tyco Electronics Corporation,  
a TE Connectivity Ltd. company.  
General Purpose  
High Power PCB Relays  
PPootttteerr && BBrruummeelldd  
T92 Series Two-pole Power Relay (Continued)  
Product Code  
T92P7A22-24  
T92P7A22-120  
T92P7A22-240  
T92P7A22-277  
T92P7A24-240  
T92P7A52-120  
T92P7A52-240  
T92P7D12-12  
T92P7D14-12  
T92P7D12-24  
T92P7D22-12  
T92P7D22-24  
T92P7D22-48  
T92P7D24-12  
T92P7D24-24  
T92P7D42-24  
T92P7D52-12  
T92P7D52-24  
T92P11A12-120  
T92P11A22-12  
T92P11A22-24  
T92P11A22-120  
T92P11A22-240  
T92P11A22-277  
T92P11A24-240  
T92P11A42-120  
T92P11D12-12  
T92P11D22-12  
T92P11D22-24  
T92P11D24-12  
T92P11D24-24  
T92S7A12-24  
T92S7A12-120  
T92S7A12-240  
T92S7A22-24  
T92S7A22-120  
T92S7A22-240  
T92S7D12-12  
T92S7D12-24  
T92S7D12-48  
T92S7D12-110  
T92S7D14-12  
T92S7D14-24  
T92S7D22-12  
T92S7D22-18  
T92S7D22-24  
T92S7D22-110  
T92S11A12-24  
T92S11A12-120  
T92S11A12-240  
T92S11A22-12  
T92S11A22-24  
T92S11A22-120  
T92S11A22-240  
T92S11D12-12  
T92S11D12-24  
T92S11D12-48  
T92S11D12-110  
T92S11D22-12  
T92S11D22-24  
T92P7D12-12-99  
T92S7D1X-12-99  
T92S7D2X-12-99  
T92S7A22-240-00  
T92S7D12-12-00  
Enclosure  
Contacts  
Coil  
Mounting  
Contact Material  
Coil  
Part Number  
6-1393211-0  
5-1393211-7  
6-1393211-2  
6-1393211-3  
3-1423008-3  
1423008-8  
1-1423008-2  
6-1393211-5  
2-1423008-1  
6-1393211-6  
6-1393211-9  
7-1393211-1  
7-1393211-2  
2-1423008-2  
1423008-9  
Plastic dust cover 2 form A, 2 NO  
AC  
Panel mount + quick connect  
AgCdO  
24 VAC  
120 VAC  
240 VAC  
277 VAC  
240 VAC  
120 VAC  
240 VAC  
12 VDC  
12 VDC  
24 VDC  
12VDC  
AgSnOInO  
AgCdO  
Panel mount + screw terminals  
PCB terminals  
DC  
AgSnOInO  
AgCdO  
Panel mount + quick connect  
24 VDC  
48 VDC  
12VDC  
AgSnOInO  
AgCdO  
24 VDC  
7-1393211-5  
1-1423008-0  
1423967-1  
Panel mount + screw terminals  
12 VDC  
24 VDC  
120 VAC  
12 VAC  
2 form C, 2 CO  
AC  
PCB terminals  
Panel mount + quick connect  
3-1393211-8  
3-1393211-9  
4-1393211-3  
4-1393211-0  
4-1393211-4  
4-1393211-6  
3-1423008-7  
4-1393211-8  
5-1393211-0  
5-1393211-3  
5-1393211-4  
3-1423008-5  
3-1423008-6  
9-1393211-8  
9-1393211-7  
9-1393211-9  
1393212-4  
24 VAC  
120 VAC  
240 VAC  
277 VAC  
240 VAC  
120VAC  
12 VDC  
AgSnOInO  
AgCdO  
DC  
AC  
PCB terminals  
Panel mount + quick connect  
24 VDC  
12 VDC  
24 VDC  
24 VAC  
120 VAC  
240 VAC  
24 VAC  
120 VAC  
240 VAC  
12 VDC  
24 VDC  
48 VDC  
110 VDC  
12 VDC  
24 VDC  
12 VDC  
18 VDC  
24 VDC  
110 VDC  
24 VAC  
120 VAC  
240 VAC  
12 VAC  
24 VAC  
120 VAC  
240 VAC  
12 VDC  
24 VDC  
48 VDC  
110 VDC  
12 VDC  
24 VDC  
12VDC  
AgSnOInO  
AgCdO  
Wash tight  
Top sealed  
Wash tight  
2 form A, 2 NO  
PCB terminals  
Panel mount + quick connect  
PCB terminals  
1393212-2  
1393212-5  
1393212-8  
1-1393212-0  
1-1393212-1  
1393212-7  
DC  
AgSnOInO  
AgCdO  
1-1423008-6  
1-1423008-8  
1-1393212-4  
1-1393212-5  
1-1393212-7  
1-1393212-3  
8-1393211-1  
8-1393211-0  
8-1393211-2  
8-1393211-3  
8-1393211-6  
8-1393211-4  
8-1393211-7  
8-1393211-9  
9-1393211-0  
9-1393211-1  
8-1393211-8  
9-1393211-3  
9-1393211-4  
2-2071223-3  
6-1423008-1  
6-1423008-2  
2-2071223-4  
1-2071223-7  
Top sealed  
Panel mount + quick connect  
Wash tight  
Top sealed  
2 form C, 2 CO  
AC  
PCB terminals  
Panel mount + quick connect  
Wash tight  
Top sealed  
DC  
DC  
PCB terminals  
Panel mount + quick connect  
PCB terminals  
Plastic dust cover 2 form A, 2 NO  
Wash tight  
AgCdO  
Special Ag Alloy  
X (Cd Free)  
AgCdO  
12VDC  
12VDC  
240VAC  
12VDC  
Panel mount + quick connect  
PCB terminals  
Top Sealed(WG)  
Wash tight (WG)  
AC  
DC  
Note. This list represents the most common types and does not show all variants covered by this datasheet, other types on request.  
5
04-2021, Rev. 0421  
Catalog and product specification according  
to IEC 61810-1 and to be used only together  
with the ‘Definitions’ section.  
Catalog and product data is subject to the  
terms of the disclaimer and all chapters of  
the ‘Definitions’ section, available at  
http://relays.te.com/definitions  
Catalog product data, ‘Definitions’ section,  
application notes and all specifications are  
subject to change.  
www.te.com  
© 2012 Tyco Electronics Corporation,  
a TE Connectivity Ltd. company.  

相关型号:

T92S7D12-24

2 pole 30 A, 2 CO or 2 NO contacts

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TE

T92S7D12-48

T92 Series Two-pole Power Relay

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TE

T92S7D14-12

T92 Series Two-pole Power Relay

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TE

T92S7D14-24

T92 Series Two-pole Power Relay

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TE

T92S7D1X-12-99

T92 Series Two-pole Power Relay

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TE

T92S7D22-110

T92 Series Two-pole Power Relay

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TE

T92S7D22-12

T92 Series Two-pole Power Relay

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TE

T92S7D22-18

T92 Series Two-pole Power Relay

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TE

T92S7D22-24

2 pole 30 A, 2 CO or 2 NO contacts

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TE

T92S7D2X-12-99

T92 Series Two-pole Power Relay

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TE

T93

3/8 Square Multi-Turn Cermet Trimmers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
EUROQUARTZ