PolySwitch Resettable Devices  
Telecommunications & Networking Devices  
This family of telecommunication and networking  
devices was initially designed over 10 years ago to meet  
the growing demand for resettable overcurrent  
protection. These product families help provide  
protection against damage caused by power cross and  
power induction surges as defined in ITU, Telcordia  
GR1089, and UL60950. Available in chip, surface-mount,  
and radial-leaded configurations, Tyco Electronics’  
PolySwitch devices help improve the reliability of  
customer premise and network equipment world wide.  
Benefits  
Features  
• Many product choices give engineers more design  
flexibility  
• RoHS compliant  
• Resettable overcurrent protection  
• Surface-mount, radial-leaded, and chip form factors  
• Fast time-to-trip  
• Compatible with high volume electronics assembly  
• Assist in meeting regulatory equipment requirements  
• Improved line balance  
• Agency recognition: UL, CSA, TÜV  
• Resistance sorted and matched devices available  
• Low parasitic capacitance/flat impedance with  
frequency  
• Applicable for legacy POTS and modern digital  
communications equipment  
Applications  
10  
• Modems  
• PBX systems  
• Powered ethernet systems  
• Phone sets  
• MDF modules  
• VoIP (Voice over Internet Protocol) equipment  
• LAN, WAN equipment  
• Fax machines  
• Phone wall outlets  
• Alarm systems  
• Analog and digital line cards  
• T1/E1 equipment  
• Customer premise equipment  
• Access network hardware  
• xDSL modems and splitters  
187  
Application Guide for Telecommunications and Networking Devices*  
To use this guide, follow the steps below:  
1. Select your equipment type from the guide below.  
2. Select the type of protection depending on the agency and regional specifications in the second column.  
3. Select the form factor for your application.  
4. Use the Agency Specification/ PolySwitch Device Selection Guide on the next page to select a specific part number for each application  
based on the agency requirements.  
5. Parts with fast time-to-trip or low resistance are available. Please consult a Tyco Electronics representative.  
Overcurrent Protection  
Form Factor  
Region/  
Application  
Specification  
North America  
TIA-968-A,  
Radial-leaded  
TRF600-150  
TR600-150F-EX  
TRF600-160  
TRF600-400  
TRF250-120  
TRF250-120T  
TRF250-145  
TRF250-183  
TRF250-184  
TRF600-160  
TRF600-400  
Surface-mount  
TS600-170F  
Chip  
Customer Premises equipment  
IT equipment  
TS600-200F  
Analog modems, V.90 modems,  
ISDN modems, xDSL modems,  
ADSL splitters, phone sets, fax machines,  
answering machines, caller ID, internet  
appliances, PBX systems, POS terminals,  
wall plugs  
UL 60950,  
TSM600-250F  
TSM600-400F  
TS250-130F  
GR1089 Port Type 3‡  
Europe/Asia/  
South America  
ITU K.21  
TSV250-130F  
Access network equipment (†)  
Remote terminals, line repeaters,  
multiplexers, cross-connects,  
WAN equipment  
North America  
GR1089 Port Type 5‡  
TS600-170F  
TS600-200F  
TS600-400F  
TSM600-250F  
TSM600-400F  
FT600-1250**  
TS250-130F  
TSV250-130F  
Europe/Asia/  
South America  
ITU K.45  
TRF250-120  
TRF250-120T  
TRF250-145  
TRF250-183  
TRF250-184  
TRF600-160  
TRF600-400  
Central office switching equipment (†)  
Analog/POTS linecards, ISDN linecards,  
xDSL modems, ADSL/VDSL splitters,  
T1/E1 linecards, multiplexers,  
North America  
GR1089 Port Type 1‡  
TS600-170F  
TS600-200F  
TS600-400F  
TSM600-250F  
TSM600-400F  
FT600-1250**  
TS250-130F  
TSV250-130F  
CSU/DSU, servers  
Europe/Asia/  
South America  
ITU K.20  
TRF250-120  
TRF250-120T  
TRF250-145  
TRF250-183  
TRF250-184  
TRF250-183  
TRF250-184  
TRF250-055UT  
TRF250-080U  
TRF250-110U  
TRF250-120  
TRF250-120T  
TRF250-145  
TRF250-183  
TRF250-184  
TRF250-080U  
TRF250-120  
TRF250-120T  
TRF250-145  
TRF250-183  
TRF250-184  
TRF250-120  
TRF250-120T  
TRF250-145  
TRF250-183  
TRF250-184  
TCF250-180  
Primary protection modules (†)  
MDF modules, Network Interface  
Devices (NID)  
North America  
Telcordia GR-974  
Europe/Asia/  
South America  
ITU K.20  
TSL250-080F  
TS250-130F  
TSV250-130F  
TCF250-100T  
TCF250-120T  
TCF250-145T  
TCF250-180  
10  
Short-haul/intrabuilding communications  
equipment (†)  
North America  
GR1089 Port Type 2‡  
GR1089 Port Type 4‡  
TSL250-080F  
TS250-130F  
TSV250-130F  
LAN equipment, VoIP cards, cable  
telephony NIUs, wireless local loop  
handsets  
Europe/Asia/  
South America  
ITU K.21  
TS250-130F  
TSV250-130F  
188  
RoHS Compliant, ELV Compliant  
Protection Application Guide for Telecommunications and Networking Devices*  
Cont’d  
Overcurrent Protection  
Form Factor  
Region/  
Application  
Specification  
Radial-leaded  
TRF250-080U  
TRF250-120  
TRF250-120T  
TRF250-145  
TRF250-183  
TRF250-184  
Surface-mount  
TSL250-080F  
TS250-130F  
Chip  
LAN intrabuilding power cross protection  
LAN equipment, VoIP cards, IP phones  
North America  
GR1089 Port Type 4‡  
TSV250-130F  
IEEE 802.3AF/AT Power over  
Ethernet protection  
decaSMDC050F/60-2††  
Powered Ethernet switches and terminals,  
IP phones, wireless LAN base stations,  
microcellular base stations, VoIP cards  
Cable telephony powering system  
Power passing taps  
BBRF550‡‡  
*
This list is not exhaustive. Tyco Electronics welcomes our customers’ input for additional application ideas for PolySwitch resettable devices.  
For improved line balance in these applications, resistance-matched parts are recommended.  
May require additional impedance or coordination with primary protector.  
** FT600-1250 are surface mount telecom fuse devices. FT600-0500 and FT600-2000 reference also available. See telecom fuses section.  
†† For details on decaSMDC050F/60-2, see surface-mount devices section.  
‡‡ For details on BBRF series, see radial-leaded devices section.  
Agency Specification/Selection Guide for Telecommunications and Networking Devices  
Use the guide below to select the PolySwitch devices which are typically used in your application. The following pages contain the  
specifications for the part numbers recommended below. PolySwitch devices assist telecommunication equipment in meeting the applicable  
protection requirements of these industry specifications. Refer to individual agency specifications for test procedures and circuit schematics.  
Users should independently evaluate the suitability of, and test each product for their application.  
Family  
Product*  
Lightning  
Power Cross/Contact/Induction  
PRC YD/T694  
TCF250  
TCF250-100T  
ITU K.20 – 1.0kV 10/700µs  
GR-1089 Port Types 2 & 4 – 1st Level  
ITU K.20/21/45 – 0.2A2s  
ITU K.20/21/45 – 1A2s†  
GR-1089 Port Type 4 – 120VAC, 25Asc  
ITU K.20/21/45 – 230VAC, 10  
ITU K.20/21/45 – 0.2A2s  
TCF250-120T  
TCF250-145T  
TCF250-180  
ITU K.20/21/45 – 1.5kV 10/700µs  
ITU K.20/21/45 – 4.0kV 10/700µs†  
GR-1089 Port Types 2 & 4 – 1st Level  
10  
ITU K.20/21/45 – 1A2s†  
ITU K.20/21/45 – 10A2s†  
GR-1089 Port Type 4 – 120VAC, 25Asc  
*
Applies to all products which share the same prefix.  
Tested with 230V gas discharge tube primary protector.  
189  
RoHS Compliant, ELV Compliant  
Agency Specification/Selection Guide for Telecommunications and Networking Devices  
Cont’d  
Family  
Product*  
Lightning  
Power Cross/Contact/Induction  
ITU K.20 – 230VAC, 10Ω  
TRF250  
TRF250-055UT  
TRF250-080U  
ITU K.20 – 1.0kV 10/700µs  
ITU K.20 – 1.0kV 10/700µs  
GR-1089 Port Types 2 & 4 – 1st Level  
ITU K.20 – 230VAC, 10Ω  
ITU K.20 – 0.2A2s  
ITU K.20 – 1A2s†  
GR-1089 Port Type 4 – 120VAC, 25Asc  
ITU K.20/21/45 – 230VAC, 10Ω  
ITU K.20/21/45 – 0.2A2s  
TRF250-110U  
TRF250-120  
TRF250-120T  
TRF250-120U  
TRF250-120UT  
TRF250-145  
TRF250-145U  
TRF250-183  
TRF250-184  
ITU K.20/21/45 – 1.5kV 10/700µs  
ITU K.20/21/45 – 4.0kV 10/700µs†  
GR-1089 Port Types 2 & 4 – 1st Level  
ITU K.20/21/45 – 1A2s†  
ITU K.20/21/45 – 10A2s†  
GR-1089 Port Type 4 – 120VAC, 25Asc  
ITU K.20/21/45 – 1.5kV 10/700µs  
ITU K.20/21/45 – 4.0kV 10/700µs‡  
GR-1089 Port Types 2 & 4 – 1st Level  
ITU K.20/21/45 – 230VAC, 10**  
ITU K.20/21/45 – 0.2A2s  
ITU K.20/21/45 – 1A2s‡  
ITU K.20/21/45 – 10A2s‡  
GR-1089 Port Type 4 – 120VAC, 25Asc  
ITU K.20/21/45 – 230VAC, 10Ω  
ITU K.20/21/45 – 0.2A2s  
TS250/TSV250  
TSV250-130F  
TS250-130F  
ITU K.20/21/45 – 1.5kV 10/700µs  
ITU K.20/21/45 – 4.0kV 10/700µs†  
GR-1089 Port Types 2 & 4 – 1st Level  
ITU K.20/21/45 – 1A2s†  
ITU K.20/21/45 – 10A2s†  
GR-1089 Port Type 4 – 120VAC, 25Asc  
ITU K.20/21/45 – 230VAC, 10Ω  
ITU K.20/21/45 – 0.2A2s  
TS250-130F-RB  
TSL250-080F  
ITU K.20/21/45 – 1.5kV 10/700µs  
ITU K.20/21/45 – 4.0kV 10/700µs‡  
GR-1089 Port Types 2 & 4 – 1st Level  
ITU K.20/21/45 – 1A2s‡  
ITU K.20/21/45 – 10A2s‡  
GR-1089 Port Type 4 – 120VAC, 25Asc  
GR-1089 Port Type 4 – 120VAC, 25Asc  
ITU K.20/21/45 – 230VAC, 10Ω  
ITU K.20/21/45 – 0.2A2s  
TSL250  
TRF600  
GR-1089 Port Types 2 & 4 – 1st Level  
ITU K.20 – 1.0kV 10/700µs  
ITU K.20/21/45 – 1A2s†  
TRF600-150  
TIA-968-A Types A & B  
UL60950 – 600VAC, 40Asc  
TR600-150F-EX  
GR-1089 Port Types 1, 3, & 5 – 1st & 2nd Level†† UL60950 – 600VAC, 40Asc  
TR600-150F-EX-RA-B-0.5 GR-1089 Port Types 1, 3, & 5 – 1st & 2nd Level†† UL60950 – 600VAC, 40Asc  
TRF600-160  
GR-1089 Port Types 1, 3, & 5 – 1st & 2nd Level†† Telcordia GR-1089 – 600VAC, 60Asc  
TRF600-400  
GR-1089 Port Types 1, 3, & 5 – 1st & 2nd Level  
TIA-968-A Types A & B  
Telcordia GR-1089 – 600VAC, 60Asc  
UL60950 – 600VAC, 40Asc  
10  
TS600  
TS600-170F  
TS600-200F-RA  
TS600-400F  
GR-1089 Port Types 1, 3, & 5 – 1st & 2nd Level†† Telcordia GR-1089 – 600VAC, 60Asc  
TSM600  
TSM600-250F  
TSM600-250F-RA  
TSM600-400F  
TIA-968-A Types A & B  
UL60950 – 600VAC, 40Asc  
GR-1089 Port Types 1, 3, & 5 – 1st & 2nd Level†† Telcordia GR-1089 – 600VAC, 60Asc  
TIA-968-A Types A & B  
UL60950 – 600VAC, 40Asc  
GR-1089 Port Types 1, 3, & 5 – 1st & 2nd Level  
TIA-968-A - Types A & B  
Telcordia GR-1089 – 600VAC, 60Asc  
UL60950 – 600VAC, 40Asc  
FT600‡‡  
FT600-0500  
FT600-1250  
FT600-2000  
GR-1089 Port Types 1, 3, & 5 – 1st & 2nd Level  
Telcordia GR-1089 – 600VAC, 60Asc  
*
Applies to all products which share the same prefix.  
Tested with 230V gas discharge tube primary protector.  
Tested with 350V gas discharge tube primary protector.  
** See SCD for additional application fault ratings.  
†† May require additional series resistor to help telecommunication equipment pass Surge 3 (1kV, 10/1000µs).  
‡‡ See telecom fuses section.  
190  
RoHS Compliant, ELV Compliant  
Product Series: Size, Current Rating, Voltage Rating, Typical Resistance for  
Telecommunications and Networking Devices  
Table T1  
TS600  
TCF250  
TRF250  
TS250  
TSV250  
TSL250  
TSM600  
TRF600  
Voltage Rating (VAC)*  
(Interrupt)  
250  
250  
250  
250  
250  
600  
600  
ITU  
ITU  
ITU  
ITU  
UL60950  
GR-1089  
UL60950  
GR-1089  
GR-1089  
Ports 2 & 4  
GR-1089  
Ports 2 & 4  
GR-1089  
Ports 2 & 4  
GR-1089  
Ports 2 & 4  
GR-1089  
Specification  
Hold Current (A)  
0.055  
Ports 2 & 4  
Ports 1, 3, & 5 Ports 1, 3, & 5  
20.0Ω  
17.0Ω  
8.0Ω  
0.080  
0.100  
11.0Ω  
0.110  
7.0Ω  
8.0Ω  
0.120  
10.5Ω  
0.130  
9.0Ω  
5.5Ω  
0.145  
7.0Ω  
4.5Ω  
0.150  
8.0Ω  
6.0Ω  
0.160  
0.170  
11.0Ω  
0.183  
1.3Ω  
1.9Ω  
0.184  
0.200  
8.5Ω  
3.5Ω  
1.2Ω  
0.250  
0.400  
1.2Ω  
Voltage Ratings forTelecommunications and Networking Devices  
For Raychem circuit protection telecommunications devices there are two applicable voltage ratings. These are VMAX Operating and  
VMAX Interrupt. To help understand the nature of these two different voltage ratings, the following definitions are provided:  
VMAX Operating: For telecommunications devices this is the voltage used to obtain component recognition under UL1434. Most Raychem  
circuit protection devices are certified at 60V but can withstand higher VMAX Interrupt conditions as noted above.  
See Table T3 for its VMAX Operating.  
*VMAX Interrupt : Under specified conditions this is the highest voltage that can be applied to the device at the maximum current. Devices  
have been designed to trip safely under higher power level cross conditions, as listed above, to assist equipment in  
meeting the appropriate industry conditions.  
10  
191  
RoHS Compliant, ELV Compliant  
Thermal Derating for Telecommunications and Networking Devices  
[Hold Current (A) at Ambient Temperature (°C)]  
Table T2  
Maximum AmbientTemperature  
Part Number  
-40°C  
-20°C  
0°C  
20°C  
40°C  
50°C  
60°C  
70°C  
85°C  
Chip* — 250VAC  
TCF250  
TCF250-100T  
TCF250-120T  
TCF250-145T  
TCF250-180‡  
0.155  
0.186  
0.225  
0.269  
0.138  
0.165  
0.199  
0.240  
0.119  
0.143  
0.172  
0.211  
0.100  
0.120  
0.145  
0.180  
0.083  
0.099  
0.119  
0.153  
0.073  
0.088  
0.106  
0.138  
0.064  
0.077  
0.093  
0.123  
0.055  
0.066  
0.080  
0.109  
0.042  
0.050  
0.060  
0.087  
Radial-leaded* — 250VAC  
TRF250  
NEW  
TRF250-055UT  
TRF250-080U  
TRF250-110U  
TRF250-120  
TRF250-145  
TRF250-183‡  
TRF250-184‡  
0.085  
0.124  
0.171  
0.186  
0.225  
0.284  
0.286  
0.076  
0.110  
0.151  
0.165  
0.199  
0.251  
0.252  
0.065  
0.095  
0.131  
0.143  
0.172  
0.217  
0.218  
0.055  
0.080  
0.110  
0.120  
0.145  
0.183  
0.184  
0.045  
0.066  
0.091  
0.099  
0.119  
0.149  
0.150  
0.041  
0.059  
0.081  
0.088  
0.106  
0.133  
0.134  
0.035  
0.051  
0.071  
0.077  
0.093  
0.117  
0.118  
0.030  
0.044  
0.061  
0.066  
0.080  
0.101  
0.102  
0.023  
0.033  
0.046  
0.050  
0.060  
0.075  
0.075  
NEW  
Surface-mount* — 250VAC  
TS250/TSL250/TSV250  
TSL250-080F  
TS250-130F  
TSV250-130F  
0.124  
0.208  
0.208  
0.110  
0.182  
0.182  
0.095  
0.156  
0.156  
0.080  
0.130  
0.130  
0.066  
0.104  
0.104  
0.059  
0.091  
0.091  
0.051  
0.078  
0.078  
0.044  
0.065  
0.065  
0.033  
0.045  
0.045  
Radial-leaded— 600VAC  
TRF600  
TRF600-150  
0.239  
0.239  
0.239  
0.255  
0.640  
0.209  
0.209  
0.209  
0.223  
0.560  
0.180  
0.180  
0.180  
0.192  
0.480  
0.150  
0.150  
0.150  
0.160  
0.400  
0.121  
0.121  
0.121  
0.129  
0.320  
0.107  
0.107  
0.107  
0.114  
0.270  
0.093  
0.093  
0.093  
0.099  
0.230  
0.079  
0.079  
0.079  
0.084  
0.190  
0.057  
0.057  
0.057  
0.061  
0.130  
TR600-150F-EX  
TR600-150F-EX-RA  
TRF600-160  
NEW  
TRF600-400  
Surface-mount— 600VAC  
TS600/TSM600  
TS600-170F  
0.264  
0.310  
0.640  
0.400  
0.400  
0.640  
0.230  
0.275  
0.560  
0.350  
0.350  
0.560  
0.200  
0.238  
0.480  
0.300  
0.300  
0.480  
0.170  
0.200  
0.400  
0.250  
0.250  
0.400  
0.140  
0.165  
0.320  
0.198  
0.198  
0.320  
0.125  
0.147  
0.270  
0.170  
0.170  
0.270  
0.109  
0.128  
0.230  
0.140  
0.140  
0.230  
0.094  
0.110  
0.190  
0.117  
0.117  
0.190  
0.070  
0.083  
0.130  
0.083  
0.083  
0.130  
TS600-200F-RA-B-0.5  
TS600-400F  
TSM600-250F  
TSM600-250F-RA  
TSM600-400F  
*
250VAC interrupt products are designed to help equipment pass ITU K.20, K.21, & K.45 recommendations and Telcordia GR-1089 Port Type 2 & 4 requirements.  
600VAC interrupt products are designed to help equipment pass UL60950, TIA-968-A and GR1089 Port Type 1, 3 & 5 requirements.  
Product is not currently available in a resistance matched or sorted option.  
Figure T1 Thermal Derating [Hold Current (A) at Ambient Temperature (°C)]  
Figure T1  
10  
A
B
=
=
TCF250-180  
All other TCF, TRF,  
TSx, TSM series devices  
200  
150  
100  
50  
B
A
A
B
0
-40  
-20  
0
20  
40  
60  
80  
Device’s AmbientTemperature (˚C)  
192  
RoHS Compliant, ELV Compliant  
Table T3 Electrical Characteristics for Telecommunications and Networking Devices  
VMAX  
IMAX  
*
Part  
Number  
IH  
(A)  
IT  
(A)  
Operating Interrupt  
Interrupt  
(A)  
PDTyp  
(W)  
TypicalTime-to-trip  
RMIN  
()  
RMAX  
()  
R1MAX  
()  
(VDC  
)
(VRMS  
)
(A)  
(s)  
Chip* — 250VAC  
TCF250  
TCF250-100T  
TCF250-120T  
TCF250-145T  
TCF250-180‡  
0.100  
0.120  
0.145  
0.180  
0.150  
0.240  
0.290  
0.650  
60  
60  
60  
60  
250  
250  
250  
250  
3.0  
3.0  
3.0  
3.0  
0.6  
1.0  
1.0  
0.9  
1.0  
1.0  
1.0  
1.0  
0.2  
0.6  
14.0  
6.3  
5.0  
1.0  
18.0  
12.0  
9.0  
24.0  
18.0  
14.0  
4.0  
1.5  
15.5  
2.2  
Radial-leaded* — 250VAC  
TRF250  
NEW  
TRF250-055UT  
TRF250-080T  
TRF250-080U  
TRF250-110U  
TRF250-120  
0.055  
0.080  
0.080  
0.110  
0.120  
0.120  
0.120  
0.130  
0.120  
0.120  
0.120  
0.120  
0.120  
0.145  
0.145  
0.145  
0.145  
0.145  
0.183  
0.184  
0.170  
0.160  
0.160  
0.220  
0.240  
0.240  
0.240  
0.260  
0.240  
0.240  
0.240  
0.240  
0.240  
0.290  
0.290  
0.290  
0.290  
0.290  
0.685  
1.000  
60  
60  
60  
60  
60  
60  
60  
60  
60  
60  
60  
60  
60  
60  
60  
60  
60  
60  
250  
250  
250  
250  
250  
250  
250  
250  
250  
250  
250  
250  
250  
250  
250  
250  
250  
250  
250  
250  
3.0  
3.0  
3.0  
3.0  
3.0  
3.0  
3.0  
3.0  
3.0  
3.0  
3.0  
3.0  
3.0  
3.0  
3.0  
3.0  
3.0  
3.0  
10.0  
10.0  
0.6  
0.6  
0.6  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
0.9  
0.9  
0.28  
0.35  
0.35  
1.00  
1.00  
0.35  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
3.00  
3.00  
3.0  
2.5  
2.5  
0.8  
1.5  
0.7  
1.2  
1.5  
0.9  
1.0  
0.8  
1.0  
0.7  
2.5  
2.5  
2.0  
1.5  
2.0  
0.6  
0.5  
15.0  
15.0  
14.0  
5.0  
4.0  
7.0  
7.0  
5.4  
6.0  
6.0  
8.0  
6.0  
7.0  
3.0  
3.0  
4.5  
5.4  
3.5  
0.8  
1.2  
25.0  
22.0  
20.0  
9.0  
35.0  
33.0  
33.0  
16.0  
16.0  
16.0  
16.0  
14.0  
16.0  
16.0  
16.0  
16.0  
16.0  
14.0  
12.0  
14.0  
14.0  
14.0  
3.4  
8.0  
TRF250-120T  
TRF250-120T-RA  
TRF250-120T-RC  
TRF250-120T-RF  
TRF250-120T-R1  
TRF250-120T-R2  
TRF250-120U  
TRF250-120UT  
TRF250-145  
12.0  
9.0  
7.5  
10.5  
9.0  
10.5  
10.0  
12.0  
6.0  
TRF250-145-RA  
TRF250-145-RB  
TRF250-145T  
TRF250-145U  
TRF250-183‡  
5.5  
6.0  
7.5  
6.5  
100  
100  
2.2  
TRF250-184‡  
2.4  
3.1  
NEW  
Surface-mount* — 250VAC  
TS250/TSL250/TSV250  
TSL250-080F  
TS250-130F  
0.080  
0.130  
0.240  
0.260  
80  
60  
60  
60  
60  
60  
60  
60  
60  
60  
250  
250  
600  
250  
600  
250  
600  
250  
600  
250  
3.0  
3.0  
1.0  
3.0  
1.0  
3.0  
1.0  
3.0  
1.0  
3.0  
1.2  
1.1  
1.0  
1.0  
0.8  
0.9  
5.0  
6.5  
11.0  
12.0  
20.0**  
20.0**  
TS250-130F-RA  
TS250-130F-RB  
TS250-130F-RC  
TSV250-130F  
0.130  
0.260  
1.1  
1.0  
1.4  
6.5  
9.0  
15.0**  
0.130  
0.260  
1.1  
1.0  
0.7  
9.0  
12.0  
20.0**  
0.130  
0.260  
1.1  
1.0  
1.1  
7.0  
10.0  
17.0**  
0.130  
0.260  
1.5  
1.0  
2.0  
4.0  
7.0  
12.0**  
10  
Radial-leaded— 600VAC  
TRF600  
TRF600-150  
0.150  
0.130  
0.150  
0.150  
0.160  
0.160  
0.160  
0.400  
0.300  
0.260  
0.300  
0.300  
0.320  
0.320  
0.320  
1.000  
250  
250  
250  
250  
250  
250  
250  
60  
600  
600  
600  
600  
600  
600  
600  
600  
3.0  
3.0  
3.0  
3.0  
3.0  
3.0  
3.0  
3.0  
1.0  
1.0  
1.4  
1.4  
1.7  
1.7  
1.7  
2.4  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
3.0  
1.4  
1.0  
5.0  
5.0  
7.5  
9.5  
9.0  
4.0  
6.0  
9.0  
6.0  
7.0  
4.0  
4.0  
4.0  
0.95  
10.0  
12.0  
12.0  
10.0  
10.0  
7.0  
17.0  
22.0  
22.0  
20.0  
18.0  
16.0  
17.0  
1.90  
TRF600-150-RB  
TR600-150F-EX  
TR600-150F-EX-RA-B-0.5  
TRF600-160  
TRF600-160-RA  
TRF600-160-R1  
TRF600-400  
8.0  
NEW  
1.45  
*
250VAC interrupt products are designed to help equipment pass ITU K.20, K.21, & K.45 recommendations and Telcordia GR-1089 Port Type 2 & 4 requirements.  
600VAC interrupt products are designed to help equipment pass UL60950, TIA-968-A and GR1089 Port Type 1, 3 & 5 requirements.  
Product is not currently available in a resistance matched or sorted option.  
** R1MAX measured 1 hour post-trip, or 24 hours post-reflow at 20°C.  
193  
RoHS Compliant, ELV Compliant  
Table T3 Electrical Characteristics for Telecommunications and Networking Devices  
Cont’d  
VMAX  
Operating Interrupt  
IMAX  
*
Part  
Number  
IH  
(A)  
IT  
(A)  
Interrupt  
(A)  
PDTyp  
(W)  
TypicalTime-to-trip  
RMIN  
()  
RMAX  
()  
R1MAX  
()  
(VDC  
)
(VRMS  
)
(A)  
(s)  
Surface-mount— 600VAC  
TS600/TSM600  
TS600-170F  
0.170  
0.400  
0.400  
1.000  
0.860  
0.860  
1.000  
60  
60  
600  
600  
600  
600  
600  
600  
3.0  
3.0  
3.0  
3.0  
3.0  
3.0  
2.5  
2.5  
2.0  
2.0  
2.0  
2.0  
1.0  
1.0  
3.0  
3.0  
3.0  
3.0  
10.0  
12.0  
5.0  
4.0  
9.0  
7.5  
1.5  
3.5  
3.0  
1.5  
18.0  
13.5  
2.0  
TS600-200F-RA-B-0.5 0.200  
4.0  
0.5  
1.0  
1.0  
0.5  
TS600-400F  
TSM600-250F  
TSM600-250F-RA  
TSM600-400F  
Notes:  
0.400  
0.250  
0.250  
0.400  
60  
250  
250  
250  
0.8  
7.0  
1.0  
5.0  
5.0  
2.0  
IH  
IT  
: Hold current: maximum current device will pass without interruption in 20°C still air.  
: Trip current: minimum current that will switch the device from low resistance to high resistance in 20°C still air.  
VMAX Operating : Maximum continuous voltage device can withstand without damage at rated current. This voltage is used for component recognition under UL1434.  
VMAX Interrupt : Maximum voltage that can be safely placed across a device in its tripped state. Devices have been designed to trip safely under higher level power cross conditions  
to assist equipment in meeting the appropriate ITU, UL60950, or GR1089 industry requirements.  
IMAX Interrupt : Maximum fault current device can withstand without damage at rated operating voltage. This current is used for component recognition under UL1434.  
Devices have been designed to trip safely under higher level power cross conditions to assist equipment in meeting the appropriate ITU, UL60950, or GR1089  
industry requirements.  
PD  
: Power dissipated from device when in the tripped state in 20°C still air.  
: Minimum resistance of device as supplied at 20°C unless otherwise specified.  
: Maximum resistance of device as supplied at 20°C unless otherwise specified.  
: Maximum resistance measured one hour post-trip or post-reflow at 20°C.  
RMIN  
RMAX  
R1MAX  
*
250VAC interrupt products are designed to help equipment pass ITU K.20, K.21, & K.45 recommendations and Telcordia GR-1089 Port Type 2 & 4 requirements.  
600VAC interrupt products are designed to help equipment pass UL60950, TIA-968-A and GR1089 Port Type 1, 3 & 5 requirements.  
Warning :  
• Users should independently evaluate the suitability of and test each product selected for their own application.  
• Operation beyond the maximum ratings or improper use may result in device damage and possible electrical arcing and flame.  
• These devices are intended for protection against damage caused by occasional overcurrent or overtemperature fault conditions and should  
not be used when repeated fault conditions or prolonged trip events are anticipated.  
Contamination of the PPTC material with certain silicone-based oils or some aggressive solvents can adversely impact the performance of the devices.  
• Device performance can be impacted negatively if devices are handled in a manner inconsistent with recommended electronic, thermal, and  
mechanical procedures for electronic components.  
• PPTC devices are not recommended for installation in applications where the device is constrained such that its PTC properties are inhibited,  
for example in rigid potting materials or in rigid housings, which lack adequate clearance to accommodate device expansion.  
• Operation in circuits with a large inductance can generate a circuit voltage (Ldi/dt) above the rated voltage of the device.  
10  
Figure T2-T13 Dimension Figures for Telecommunications and Networking Devices  
Figure T2  
Figure T3  
Figure T4  
A
C
A
C
A
C
B
D
B
D
B
E
E
to  
to  
C
C
L
L
C
C
L
L
194  
RoHS Compliant, ELV Compliant  
Figure T2-T13 Dimension Figures for Telecommunications and Networking Devices  
Cont’d  
Figure T5  
Figure T6  
Figure T7  
A
C
C
B
C
B
D
B
E
E
F
D
D
A
D
E
A
Figure T8  
Figure T9  
C
C
B
F
F
B
E
E
D
D
A
G
E
A
D
Figure T10  
Figure T11  
Figure T12  
A
C
A
C
A
C
B
D
B
B
D
D
E
E
E
to  
C
C
L
to  
C
L
C
L
L
to  
C
C
L
L
10  
Figure T13  
A
C
B
D
E
to  
C
C
L
L
195  
RoHS Compliant, ELV Compliant  
Table T4 Dimensions for Telecommunications and Networking Devices in Millimeters (Inches)  
A
B
C
D
E
F
G
Part Number  
Min. Max.  
Min. Max.  
Min. Max.  
Min. Max.  
Min. Max.  
Min. Max.  
Min. Max.  
Figure  
TCF  
250V*  
TCF250-100T  
TCF250-120T  
TCF250-145T  
TCF250-180  
4.6  
(0.18) (0.19) (0.18) (0.19)  
5.4 5.6 5.4 5.6  
(0.21) (0.22) (0.21) (0.22)  
5.4 5.6 5.4 5.6  
(0.21) (0.22) (0.21) (0.22)  
6.9 7.1 6.9 7.1  
(0.27) (0.28) (0.27) (0.28)  
4.9  
4.6  
4.9  
2.0  
(0.08) (0.09)  
2.0 2.3  
(0.08) (0.09)  
2.0 2.5  
(0.08) (0.10)  
1.3 1.6  
(0.05) (0.06)  
2.3  
T4  
T4  
T4  
T4  
TRF250  
250V*  
NEW  
TRF250-055UT  
TRF250-080T  
TRF250-080U  
TRF250-110U  
TRF250-120  
TRF250-120U  
TRF250-145  
TRF250-145U  
TRF250-183  
TRF250-184  
4.8  
(0.19)  
5.8  
9.3  
(0.37)  
9.9  
3.8  
4.7  
5.0‡  
(0.20)  
5.0‡  
T2  
(0.15) (0.19)  
4.6 4.7  
(0.18) (0.19)  
3.8 4.7  
(0.15) (0.19)  
3.8 4.7  
(0.15) (0.19)  
4.6 4.7  
(0.18) (0.19)  
3.8 4.7  
(0.15) (0.19)  
4.6 4.7  
(0.18) (0.19)  
3.8 4.7  
(0.15) (0.19)  
4.1 4.7  
(0.16) (0.19)  
4.6 4.7  
(0.18) (0.19)  
T2  
(0.23)  
4.8  
(0.39)  
9.3  
(0.20)  
5.0‡  
T11  
T11  
T3  
(0.19)  
5.3  
(0.37)  
9.4  
(0.20)  
5.0‡  
(0.21)  
6.5  
(0.37)  
11.0  
(0.43)  
10.0  
(0.39)  
11.0  
(0.43)  
10.0  
(0.39)  
10.5  
(0.41)  
10.5  
(0.41)  
(0.20)  
5.0‡  
(0.26)  
6.0  
(0.20)  
5.0‡  
T10  
T3  
(0.24)  
6.5  
(0.20)  
5.0‡  
(0.26)  
6.0  
(0.20)  
5.0‡  
T10  
T2  
(0.24)  
7.5  
(0.20)  
5.0‡  
(0.29)  
7.7  
(0.20)  
5.0‡  
NEW  
T12  
(0.30)  
(0.20)  
TS250/TSL250/TSV250  
250V*  
TSL250-080F  
TS250-130F  
TSV250-130F  
6.7  
7.9  
2.7  
3.7  
4.8  
5.3  
0.2  
0.4  
2.5  
3.1  
T7  
T5  
T6  
(0.27) (0.31) (0.11) (0.15)  
(0.19) (0.21) (0.01) (0.02) (0.10) (0.12)  
8.5  
9.4  
3.4  
(0.14)  
6.9  
7.4  
(0.29) (0.01)  
3.2 0.56  
(0.13) (0.02)  
0.3‡  
3.8‡  
(0.15)  
(0.34) (0.37)  
6.1  
1.9  
1.6  
2.3  
(0.24)  
(0.27)  
(0.08)  
(0.07) (0.09)  
10  
TRF600  
600V†  
TRF600-150  
9.0  
12.5  
(0.49)  
12.6  
4.6  
(0.18) (0.19)  
6.0 4.7  
(0.18) (0.19)  
6.0 4.7  
(0.18) (0.19)  
6.0 4.7  
(0.24) (0.19)  
4.6 4.7  
(0.18) (0.19)  
4.7  
5.0  
(0.20)  
5.0  
9.0  
(0.35)  
T3  
T3  
(0.35)  
13.5  
TR600-150F-EX  
TR600-150F-EX-RA-B-0.5  
TRF600-160  
(0.53)  
13.5  
(0.50)  
12.6  
(0.20)  
5.0  
T3  
(0.53)  
16.0  
(0.50)  
12.6  
(0.20)  
5.0‡  
10.0  
(0.39)  
T3  
(0.63)  
14.8  
(0.50)  
13.1  
(0.20)  
5.0‡  
NEW  
TRF600-400  
T13  
(0.58)  
(0.52)  
(0.20)  
*
250VAC interrupt products are designed to help equipment pass ITU K.20, K.21, & K.45 recommendations and Telcordia GR-1089 Port Type 2 & 4 requirements.  
600VAC interrupt products are designed to help equipment pass UL60950, TIA-968-A and GR1089 Port Type 1, 3 & 5 requirements.  
Indicates dimension is typical, not minimum.  
196  
RoHS Compliant, ELV Compliant  
Table T4 Dimensions for Telecommunications and Networking Devices in Millimeters (Inches)  
Cont’d  
A
B
C
D
E
F
G
Part Number  
Min. Max.  
Min. Max.  
Min. Max.  
Min. Max.  
Min. Max.  
Min. Max.  
Min. Max.  
Figure  
TS600/TSM600  
600V†  
TS600-170F  
18.3  
(0.72) (0.77) (0.46) (0.49)  
18.3 19.4 11.6 12.3  
(0.72) (0.77) (0.46) (0.49)  
18.3 19.4 11.6 12.3  
19.4  
11.6  
12.3  
7.2  
(0.29) (0.33) (0.07) (0.10) (0.39) (0.41)  
7.2 8.3 1.7 2.4 9.9 10.4  
(0.29) (0.33) (0.07) (0.10) (0.39) (0.41)  
7.2 8.3 1.7 2.4 9.9 10.4  
(0.29) (0.33) (0.07) (0.10) (0.39) (0.41)  
10.40 11.20 4.80 5.20 2.50 2.80  
(0.41) (0.44) (0.19) (0.20) (0.10) (0.11)  
10.40 11.20 4.80 5.20 2.50 2.80  
(0.41) (0.44) (0.19) (0.20) (0.10) (0.11)  
10.40 11.20 4.80 5.20 2.50 2.80  
(0.41) (0.44) (0.19) (0.20) (0.10) (0.11)  
8.3  
1.7  
2.4  
9.9  
10.4  
1.5  
(0.06) (0.09)  
1.5 2.3  
(0.06) (0.09)  
1.5 2.3  
(0.06) (0.09)  
0.60 1.0  
2.3  
T8  
T8  
T8  
T9  
T9  
T9  
TS600-200F-RA  
TS600-400F  
(0.72) (0.77) (0.46) (0.49)  
17.00 17.60 11.20 11.70  
(0.67) (0.69) (0.44) (0.46)  
17.00 17.60 11.20 11.70  
(0.67) (0.69) (0.44) (0.46)  
17.00 17.60 11.20 11.70  
(0.67) (0.69) (0.44) (0.46)  
TSM600-250F  
TSM600-250F-RA  
TSM600-400F  
2.2  
3.1  
(0.02) (0.04) (0.09) (0.12)  
0.60 1.0 2.2 3.1  
(0.02) (0.04) (0.09) (0.12)  
0.60 1.0 2.2 3.1  
(0.02) (0.04) (0.09) (0.12)  
600VAC interrupt products are designed to help equipment pass UL60950, TIA-968-A and GR1089 Port Type 1, 3 & 5 requirements.  
Typical Time-to-trip Curves at 20°C for  
Telecommunications and Networking Devices  
Figure T14-T17  
Figure T14  
TCF250  
A
B
C
D
=
=
=
=
TCF250-180  
TCF250-145T  
TCF250-120T  
TCF250-100T  
100  
A
B
10  
C
D
1
A
0.10  
B
C
D
0.01  
0.00 0.20  
0.40  
0.60 0.80  
1.00 1.20  
1.40 1.60  
1.80  
2.00 2.20 2.40  
2.60 2.80 3.00  
Fault Current (A)  
Figure T15  
TRF250  
10  
A
B
C
D
E
=
=
=
=
=
TRF250-180/183/184  
TRF250-145/145U  
1000  
100  
10  
TRF250-120/120U  
A
TRF250-110U/120UT/120T  
TRF250-080T/080U/080US  
B
C
D
E
1
A
B
C
0.10  
D
E
0.01  
0.00 0.20  
0.40  
0.60 0.80  
1.00 1.20  
1.40 1.60  
1.80  
2.00 2.20 2.40  
2.60 2.80 3.00  
Fault Current (A)  
197  
RoHS Compliant, ELV Compliant  
Typical Time-to-trip Curves at 20°C for  
Telecommunications and Networking Devices  
Figure T14-T17  
Cont’d  
Figure T16  
TS250/TSV250/TSL250  
A
B
C
=
=
=
TSV250-130F  
TS250-130F  
TSL250-080F  
100  
10  
A
B
C
1
A
B
C
0.10  
0.01  
0.00  
0.50  
1.00  
1.50  
2.00  
2.50  
3.00  
Fault Current (A)  
Figure T17  
TRF600/TS600/TSM600  
A
=
TRF600-400/TS600-400/  
TSM600-400F  
1000  
B
=
TSM600-250F/  
TS600-170F/200F  
TRF600-160  
B
C
D
A
100  
10  
C
D
E
=
=
=
E
TR600-150F-EX  
TRF600-150  
A
B
1
C
D
E
0.10  
0
1
2
3
4
5
6
7
Fault Current (A)  
Physical Characteristics and Environmental Specifications for  
Telecommunications and Networking Devices  
Table T5  
10  
Operating temperature range for all listed products is -40°C to 85°C, except forTRF250-080T andTRF250-184 (0°C to 85°C)  
TCF250*  
Physical Characteristics  
Terminal material  
Nickel-plated copper foil  
Environmental Specifications  
Test  
Conditions  
Passive aging  
60°C, 1000 hours  
85°C, 1000 hours  
Humidity aging  
Thermal shock  
Solvent resistance  
85°C, 85% RH, 1000 hours  
125°C, -55°C (10 times)  
MIL-STD-202, Method 215F  
Note: Storage conditions: 40°C max., 70% RH max., devices should remain in original sealed bag prior to use. Devices may not meet specified values if these storage conditions are exceeded.  
*
250VAC interrupt products are designed to help equipment pass ITU K.20, K.21, & K.45 recommendations and Telcordia GR-1089 Port Type 2 & 4 requirements.  
RoHS compliant, ELV compliant  
198  
Physical Characteristics and Environmental Specifications for  
Telecommunications and Networking Devices  
Table T5  
Cont’d  
Operating temperature range for all listed products is -40°C to 85°C, except forTRF250-080T andTRF250-184 (0°C to 85°C)  
TRF250*  
Physical Characteristics  
Lead material  
Tin-plated copper, 22AWG  
Insulating material  
Flammability  
Cured epoxy polymer  
per IEC 695-2-2 Needle Flame Test for 20s  
Soldering characteristics  
Solder heat withstand  
ANSI/J-STD-002, Category 3  
IEC-STD 68-2-20, Test Tb, Section 5 Method 1A, Condition B: can withstand 10 seconds at 260°C 5°C  
Note: Devices are not designed to be placed through a reflow process.  
Environmental Specifications  
Test  
Conditions  
Passive aging  
60°C, 1000 hours  
85°C, 1000 hours  
Humidity aging  
Thermal shock  
Solvent resistance  
85°C, 85% RH, 1000 hours  
125°C, -55°C (10 times)  
MIL-STD-202, Method 215F  
Note: Storage conditions: 40°C max., 70% RH max., devices should remain in original sealed bag prior to use. Devices may not meet specified values if these storage conditions are exceeded.  
TS250/TSV250/TSL250*  
Physical Characteristics  
Terminal material  
Soldering characteristics  
Tin-plated brass, Nickel under-plating  
EIC 60008-2-58  
Environmental Specifications  
Test  
Conditions  
Passive aging  
60°C, 1000 hours  
85°C, 1000 hours  
Humidity aging  
Thermal shock  
Solvent resistance  
85°C, 85% RH, 500 hours  
125°C, -55°C (10 times)  
MIL-STD-202, Method 215F  
Note: Storage conditions: 40°C max., 70% RH max., devices should remain in original sealed bag prior to use. Devices may not meet specified values if these storage conditions are exceeded.  
TRF600†  
Physical Characteristics  
Lead material  
Insulating material  
Flammability  
Tin-plated copper, 22AWG  
Cured epoxy polymer‡  
per IEC 695-2-2 Needle flame test for 20s  
Soldering characteristics  
Solder heat withstand  
ANSI/J-STD-002, Category 3  
IEC-STD 68-2-20, Test Tb, Section 5 Method 1A, Condition B: can withstand 10 seconds at 260°C 5°C  
10  
Note: Devices are not designed to be placed through a reflow process.  
Environmental Specifications  
Test  
Conditions  
Passive aging  
60°C, 1000 hours  
85°C, 1000 hours  
Humidity aging  
Thermal shock  
Solvent resistance  
85°C, 85% RH, 1000 hours‡  
125°C, -55°C (10 times)  
MIL-STD-202, Method 215F  
Note: Storage conditions: 40°C max., 70% RH max., devices should remain in original sealed bag prior to use. Devices may not meet specified values if these storage conditions are exceeded.  
*
250VAC interrupt products are designed to help equipment pass ITU K.20, K.21, & K.45 recommendations and Telcordia GR-1089 Port Type 2 & 4 requirements.  
600VAC interrupt products are designed to help equipment pass UL60950, TIA-968-A and GR1089 Port Type 1, 3 & 5 requirements.  
Excluding TRF600-150 and TRF600-400, which have a coating that is not rated for dielectric withstand and can withstand 500h at 85°C/85% RH or 1000h at 60°C/90% RH.  
199  
RoHS Compliant, ELV Compliant  
Physical Characteristics and Environmental Specifications for  
Telecommunications and Networking Devices  
Table T5  
Cont’d  
Operating temperature range for all listed products is -40°C to 85°C, except forTRF250-080T andTRF250-184 (0°C to 85°C)  
TS600†  
Physical Characteristics  
Terminal material  
Tin-plated brass  
Insulating material  
Flammability  
Nylon resin (UL94V-0), 1000V dielectric rating  
IEC 695-2-2 Needle Flame Test for 20s  
ANSI/J-STD-002, Category 3  
Soldering characteristics  
Solder heat withstand  
IEC-STD 68-2-20, Test Tb, Section 5 Method 1A  
Environmental Specifications  
Test  
Conditions  
Passive aging  
60°C, 1000 hours  
85°C, 1000 hours  
Humidity aging  
Thermal shock  
85°C, 85% RH, 1000 hours  
125°C, -55°C (10 times)  
MIL-STD-202, Method 215F  
Solvent resistance  
Note: Storage conditions: 40°C max., 70% RH max., devices should remain in original sealed bag prior to use. Devices may not meet specified values if these storage conditions are exceeded.  
TSM600†  
Physical Characteristics  
Terminal material  
Tin-plated brass  
Insulating material  
Flammability  
Nylon resin (UL94V-0), 1000V dielectric rating  
IEC 695-2-2 Needle Flame Test for 20s  
EIC60068-2-58, Method 7  
Soldering characteristics  
Solder heat withstand  
IEC-STD 68-2-20, Test Tb, Section 5 Method 1A  
Environmental Specifications  
Test  
Conditions  
Passive aging  
60°C, 1000 hours  
85°C, 1000 hours  
Humidity aging  
Storage humidity  
Thermal shock  
85°C, 85% RH, 1000 hours  
Per IPC/JEDEC J-STD-020A Level 2a  
125°C, -55°C (10 times)  
MIL-STD-202, Method 215J  
Solvent resistance  
Note: Storage conditions: 40°C max., 70% RH max., devices should remain in original sealed bag prior to use. Devices may not meet specified values if these storage conditions are exceeded.  
600VAC interrupt products are designed to help equipment pass UL60950, TIA-968-A and GR1089 Port Type 1, 3 & 5 requirements.  
10  
200  
RoHS Compliant, ELV Compliant  
Table T6 Packaging and Marking Information for Telecommunications and Networking Devices  
Bag  
Quantity  
Tape & Reel  
Quantity  
Standard Package  
Quantity  
Part Number  
Part Marking  
Agency Recognition  
Chip* — 250VAC  
TCF250  
TCF250-100T  
TCF250-120T  
TCF250-145T  
TCF250-180  
2,500  
2,500  
2,500  
2,500  
10,000  
10,000  
10,000  
10,000  
UL  
Radial-leaded* — 250VAC  
TRF250  
NEW  
TRF250-055UT  
TRF250-080U  
TRF250-080U-2  
TRF250-080T  
TRF250-110U  
TRF250-120  
500  
500  
10,000  
10,000  
7,500  
UL, CSA, TÜV  
UL, CSA, TÜV  
UL, CSA, TÜV  
UL, CSA, TÜV  
UL, CSA, TÜV  
UL, CSA, TÜV  
UL, CSA, TÜV  
UL, CSA, TÜV  
UL, CSA, TÜV  
UL, CSA, TÜV  
UL, CSA, TÜV  
UL, CSA, TÜV  
UL, CSA, TÜV  
UL, CSA, TÜV  
UL, CSA, TÜV  
UL, CSA, TÜV  
UL, CSA, TÜV  
UL, CSA, TÜV  
UL, CSA, TÜV  
1,500  
500  
500  
500  
10,000  
10,000  
10,000  
7,500  
08F  
20F  
20F  
20F  
20F  
20F  
20F  
20F  
45F  
45F  
45F  
45F  
45F  
83F  
83F  
84F  
TRF250-120-2  
TRF250-120T  
TRF250-120T-2  
TRF250-120U  
TRF250-120U-2  
TRF250-120UT  
TRF250-145  
1,500  
500  
10,000  
7,500  
1,500  
500  
10,000  
7,500  
1,500  
500  
500  
10,000  
10,000  
7,500  
TRF250-145-2  
TRF250-145-RA  
TRF250-145U  
TRF250-145U-2  
TRF250-183  
1,500  
500  
500  
10,000  
10,000  
7,500  
1,500  
500  
10,000  
7,500  
TRF250-183-2  
TRF250-184  
1,500  
NEW  
500  
10,000  
Surface-mount* — 250VAC  
TS250/TSL250/TSV250  
TSL250-080F-2  
TS250-130F-2  
TSV250-130F-2  
1,500  
1,500  
1,200  
7,500  
7,500  
6,000  
T08  
UL, CSA,TÜV  
UL, CSA, TÜV  
UL, CSA, TÜV  
T13  
T13V  
Radial-leaded— 600VAC  
TRF600  
TRF600-150  
500  
1,500  
10,000  
7,500  
150F  
150F  
150F  
150F  
150F  
160F  
160F  
400F  
UL, CSA, TÜV  
UL, CSA, TÜV  
UL, CSA  
TRF600-150-2  
TR600-150F-EX  
TR600-150F-EX-2  
TR600-150F-EX-RA-B-0.5  
TRF600-160  
500  
10,000  
3,000  
600  
UL, CSA  
10  
500  
500  
10,000  
10,000  
3,000  
UL, CSA  
UL, CSA, TÜV  
UL, CSA, TÜV  
UL, CSA  
TRF600-160-2  
TRF600-400  
600  
NEW  
500  
10,000  
Surface-mount— 600VAC  
TS600/TSM600  
TS600-170F-2  
300  
300  
300  
200  
200  
200  
900  
900  
T20  
UL, CSA  
UL, CSA  
UL, CSA  
UL, CSA  
UL, CSA  
UL  
TS600-200F-RA-2  
TS600-400F-2  
T20  
900  
T40  
TSM600-250F-2  
TSM600-250F-RA-2  
TSM600-400F-2  
1,000  
1,000  
1,000  
TSM600  
TSM600  
TSM600  
*
250VAC interrupt products are designed to help equipment pass ITU K.20, K.21, & K.45 recommendations and Telcordia GR-1089 Port Type 2 & 4 requirements.  
600VAC interrupt products are designed to help equipment pass UL60950, TIA-968-A and GR1089 Port Type 1, 3 & 5 requirements.  
201  
RoHS Compliant, ELV Compliant  
Agency Recognition for Telecommunications and Networking Devices  
UL  
CSA  
TÜV  
File # E74889  
File #78165C  
Per IEC60730-1  
Certificate # for individual products available upon request.  
Recommended Pad Layouts for Surface-mount Telecommunications and Networking  
Devices in millimeters (inches) Nominal  
Table T7  
Device  
A
B
C
D
E
F
G
Figure  
TS250 (All)  
4.60  
1.80  
6.10  
T18  
(0.180)  
2.29  
(0.070)  
2.41  
(0.240)  
6.35  
TSV250 (All)  
TSL250 (All)  
TS600 (All)  
3.43  
(0.135)  
T19  
T18  
T18  
T20  
(0.090)  
3.60  
(0.095)  
1.80  
(0.250)  
5.50  
(0.140)  
10.42  
(0.410)  
5.20  
(0.070)  
3.30  
(0.220)  
3.35  
(0.130)  
17.80  
(0.701)  
(0.132)  
5.54  
TSM600 (All)  
6.75  
(0.266)  
2.08  
(0.082)  
3.12  
(0.123)  
8.39  
(0.331)  
(0.205)  
(0.218)  
Figure T18  
Figure T19  
Figure T20  
B
A
D
A
A
A
G
E
F
B
B
C
B
C
B
C
D
Solder Reflow and Rework Recommendations for Telecommunications Surface-mount Devices  
Profile Feature  
Pb-Free Assembly  
Figure T21  
Average ramp up rate (TsMAX toTp)  
Preheat  
3°C/second max.  
tp  
Critical Zone  
TL toTp  
Tp  
Ramp up  
Temperature min. (TsMIN  
Temperature max. (TsMAX  
• Time (tsMIN to tsMAX  
)
150°C  
)
200°C  
TL  
tL  
TsMAX  
)
60-180 seconds  
Time maintained above:  
Temperature (TL)  
• Time (tL)  
TsMIN  
217°C  
ts  
60-150 seconds  
260°C  
10  
Ramp down  
Preheat  
Peak/Classification temperature (Tp)  
Time within 5°C of actual peak temperature  
Time (tp)  
25  
t 25˚C to Peak  
20-40 seconds  
6°C/second max.  
8 minutes max.  
Time  
Reflow Profile  
Ramp down rate  
Time 25°C to peak temperature  
Note: All temperatures refer to topside of the package, measured on the package  
body surface.  
Solder Reflow  
• Recommended reflow method: IR, vapor phase oven, hot air oven.  
• Surface-mount devices are not designed to be wave soldered to the bottom side of the board.  
• Recommended maximum paste thickness of 0.25mm (0.010 in).  
• Devices can be cleaned using standard industry methods and solvents.  
Rework  
• If a device is removed from the board, it should be discarded and replaced with a new device.  
202  
RoHS compliant, ELV compliant  
Wave Soldering and Rework Recommendations for Telecommunications Radial-leaded Devices  
Figure T22  
Recommended Wave Soldering  
• Soldering temperature profile  
300  
10s  
Temperature characteristic at component terminal with dual  
wave soldering  
245˚C ... 260˚C  
250  
200  
150  
100  
50  
Rework  
• If a device is removed from the board, it should be discarded  
and replaced with a new device.  
100˚C ... 130˚C  
Forced cooling  
100  
0
0
50  
150  
200  
250  
Time (s)  
TRF250/TRF600 Tape and Reel Specifications for  
Table T8  
Telecommunications and Networking Device  
TRF250/TRF600 devices are available in tape and reel packaging per EIA 468-B standard. See Figures T23 and T24 for details.  
Dimension  
Description  
EIA Mark  
W
W4  
W6  
W5  
D0  
H
IEC Mark  
W
W0  
W2  
W1  
D0  
H
Dimension (mm)  
Tolerance  
-0.5/+1.0  
Minimum  
Maximum  
-0.5/+0.75  
0.2  
Carrier tape width  
18  
Hold down tape width  
Top distance between tape edges  
Sprocket hole position  
Sprocket hole diameter  
Abcissa to plane (straight lead)  
Abcissa to plane (kinked lead)*  
Abcissa to top  
5
3
9
4
18.5  
3.0  
H0  
H1  
L1  
H0  
H1  
C1  
C2  
I1  
16  
-0.5/+0.6  
Maximum  
Maximum  
Maximum  
Maximum  
Maximum  
32.2  
Overall width with lead protrusion  
Overall width without lead protrusion  
Lead protrusion  
43.2  
42.5  
1.0  
Protrusion of cut-out  
L
L
11  
Protrusion beyond hold down tape  
Sprocket hole pitch  
I2  
I2  
Not specified  
P0  
t
P0  
t
12.7  
0.3  
Device pitch (TRF250 & TRF600-150)  
Device pitch (TRF600-160/400)  
Pitch tolerance  
12.7  
25.4  
20 consecutive  
1
Tape thickness  
0.9  
Maximum  
Maximum  
0.3  
Tape thickness with splice*  
Splice sprocket hole alignment  
Body lateral deviation  
Body tape plane deviation  
Lead spacing plane deviation  
Lead spacing*  
t1  
h  
p  
P1  
F
2.0  
h  
p  
P1  
F
0
10  
0
1.0  
0
1.3  
0
5.08  
0.7  
0.6  
Reel width  
w2  
a
w
56  
Maximum  
Maximum  
3.25  
Reel diameter  
d
370  
Space between flanges less device  
Arbor hole diameter  
w1  
c
f
4.75  
26  
12.0  
Core diameter  
n
h
80  
Maximum  
Maximum  
Box  
56/372/372  
3 maximum  
Not specified  
Consecutive missing pieces*  
Empty places per reel*  
* Differs from EIA specification.  
203  
RoHS Compliant, ELV Compliant  
Figure T23 EIA Referenced Taped Component Dimensions for TRF Devices  
p  
p  
h  
h  
Reference plane  
H1  
P1  
C2  
H1  
F
C1  
H
H0  
A
B
L
W5  
W4  
W
I2  
L1  
Direction of unreeling  
P0  
D0  
Cross section A-B  
t
Figure T24 Reel Dimensions for TRF Devices  
Reel  
Upper side  
n
Type  
Direction of  
unreeling  
a
Lower side  
c
w1  
w2  
Cross section  
Optional shape: Circular or polygonal  
10  
204  
RoHS Compliant, ELV Compliant  
Table T9 TS Tape and Reel Specifications for Telecommunications and Networking Devices  
TS devices are packaged per EIA 481 and EIA 481-2 standards. See Figures T25 and T26 for details.  
TS250/TSL250/TSV250  
TS250  
TSV250  
TSL250  
Dimension  
Description  
EIA Mark Dimension(mm) Tolerance(mm)  
Dimension(mm) Tolerance(mm)  
Dimension(mm) Tolerance(mm)  
Carrier tape width  
Sprocket hole pitch  
W
P0  
16  
4.0  
0.30  
0.10  
0.10  
0.10  
0.23  
0.15  
16.0  
4.0  
0.30  
0.10  
0.10  
0.10  
0.10  
0.10  
16  
4.0  
8.0  
2.0  
5.5  
7.9  
9.2  
1.55  
7.5  
1.75  
0.30  
0.10  
0.10  
0.10  
0.10  
0.10  
P1  
12.0  
2.0  
8.0  
P2  
2.0  
A0  
6.9  
5.5  
B0  
9.6  
6.2  
B1 max.  
D0  
12.1  
1.5  
8.0  
Sprocket hole diameter  
Tape thickness  
-0/+0.1  
0.10  
0.10  
1.55  
7.5  
0.05  
0.10  
0.10  
0.05  
0.10  
0.10  
F
7.5  
E1  
1.75  
14.25  
0.4  
1.75  
E2 min.  
T max.  
0.45  
0.1  
0.35  
0.1  
Tape thickness with  
T
1 max.  
0.1  
splice cover tape thickness  
K0  
3.4  
300  
300  
0.15  
7.0  
390  
160  
0.10  
3.70  
390  
160  
0.10  
Leader min.  
Trailer min.  
Reel dimensions  
Reel diameter  
A max.  
N min.  
W1  
340  
50  
340  
50  
340  
50  
Core diameter  
Space between flanges less device  
Reel width  
16.4  
22.4  
-0/+2.0  
16.4  
22.4  
-0/+2.0  
16.4  
22.4  
-0/+2.0  
W2 max.  
TS600  
Dimension  
Description  
EIA Mark  
Dimension (mm)  
Tolerance  
Carrier tape width  
Sprocket hole pitch  
W
32  
4.0  
0.3  
0.1  
0.1  
0.1  
0.1  
0.1  
P0  
P1  
P2  
16  
2.0  
A0  
10  
B0  
19.2  
21.6  
1.5  
B1 max.  
D0  
Sprocket hole diameter  
-0/+1.0  
0.1  
10  
F
14.2  
1.75  
28.4  
0.50  
0.1  
E1  
0.1  
E2 min.  
T max.  
T1 max.  
K0  
0.1  
Tape thickness  
0.5  
Tape thickness with splice  
13.2  
390  
160  
0.1  
Leader min.  
Trailer min.  
Reel Dimensions  
Reel diameter  
A max.  
N min.  
W1  
360  
50  
Core diameter  
Space between flanges less device  
Reel width  
32.4  
40  
-0/+2.0  
W2 max.  
205  
RoHS Compliant, ELV Compliant  
Table T9 TS Tape and Reel Specifications for Telecommunications and Networking Devices  
Cont’d  
TS devices are packaged per EIA 481 and EIA 481-2 standards. See Figures T25 and T26 for details.  
TSM600  
Dimension  
Description  
EIA Mark  
Dimension (mm)  
Tolerance  
0.3  
Carrier tape width  
Sprocket hole pitch  
W
32  
4.0  
P0  
0.1  
P1  
24  
0.1  
P2  
A0  
2.0  
0.1  
11.2  
17.8  
23.45  
1.5  
0.1  
B0  
0.1  
B1 max.  
D
Sprocket hole diameter  
-0/+1.0  
0.1  
F
14.2  
1.74  
28.4  
0.5  
E1  
0.1  
E2 max.  
T max.  
T1 max.  
K0  
0.1  
Tape thickness  
0.5  
Tape thickness with splice  
0.1  
11.9  
390  
160  
0.1  
Leader min.  
Trailer min.  
Reel Dimensions  
Reel diameter  
A max.  
N min.  
W1  
360  
50  
Core diameter  
Space between flanges less device  
Reel width  
32.4  
40  
-0/+2.0  
W2 max.  
Figure T25 EIA Referenced Taped Component Dimensions for TS Devices  
Embossment  
P0  
D0  
P2  
T
E1  
Cover tape  
A0  
F
W
E2  
K0  
B0  
B1  
10  
T1  
P1  
Center lines  
of cavity  
Figure T26 EIA Referenced Reel Dimensions for TS Devices  
W
2 (measured at hub)  
A
N (hub dia.)  
Cover tape  
W1 (measured at hub)  
Carrier tape  
Embossed cavity  
206  
RoHS Compliant, ELV Compliant  
Resistance-sorted and Resistance-matched Devices  
Most TCF, TRF and TS devices are available in resistance-sorted and/or resistance-matched versions.  
Resistance-sorted Devices  
Resistance-sorted devices (part number suffix “Rx, where x = 1, 2, A, B, C, F etc.) are supplied with resistance values that are within  
specified segments of the devices full range of resistance.  
Feature  
• Narrow resistance range.  
Benefits  
• Greater flexibility for design engineers.  
• Lower resistance devices can allow for increased loop length on line card designs.  
• Higher resistance devices may provide greater protection by offering faster time-to-trip.  
Resistance-matched Devices  
Resistance-matched devices are supplied such that all parts in one particular package (or reel) are within 0.5of each other  
(1.0for TRF250-080T devices). Individual matched packages are supplied from the full resistance range of the specified device.  
Feature  
• Tighter resistance balance between any two parts in a package.  
Benefits  
• Resistance-matched devices may reduce the tip-ring resistance differential, reducing the possibility of line imbalance.  
Part Numbering System for Radial-leaded Telecommunications and Networking Devices  
TRF*250 -120 T -RA -B-0.5 -2  
Packaging  
2
=Tape and Reel  
0.130 = special lead length in inches  
(Blank) = Bulk  
B-x.x = Resistance matched in bins of x.x(optional)  
Rx = Resistance range (optional)  
Modifier (optional)  
U = Uncoated  
S = Straight lead  
T = FastTrip device  
Hold Current (mA)  
Product Series (TRF250,TRF600)  
* F = RoHS compliant, ELV compliant  
10  
Part Numbering System for Surface-mount Telecommunications and Networking Devices  
TSx -200  
F -RA -B-0.5 -2  
Packaging  
2
=Tape and Reel  
(Blank) = Bulk  
B-x.x = Resistance matched in bins of x.x(optional)  
Rx = Resistance range (optional)  
F = RoHS Compliant, ELV Compliant  
Hold Current (mA)  
Product Series (TS250,TSV250,TSL250,TS600,TSM600)  
207  
RoHS Compliant, ELV Compliant  
Part Numbering System for Chip Telecommunications and Networking Devices  
TCF*250 -120 T -RA -B-0.5  
B-x.x = Resistance matched in bins of x.x(optional)  
Rx = Resistance range (optional)  
Modifier (optional)  
T = FastTrip device  
Hold Current (mA)  
Product Series  
* F = RoHS compliant, ELV compliant  
10  
208  
RoHS Compliant, ELV Compliant  

相关型号:

TRF250-145-2

PolySwitch Resettable Devices Telecommunications & Networking Devices

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TE

TRF250-145-B-0.5

PTC Resettable Fuse, Through Hole Mount, RADIAL LEADED, ROHS COMPLIANT

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
LITTELFUSE

TRF250-145-RA

PolySwitch Resettable Devices Telecommunications & Networking Devices

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TE

TRF250-145-RA-B-0.5

PTC Resettable Fuse, Through Hole Mount, RADIAL LEADED, ROHS COMPLIANT

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
LITTELFUSE

TRF250-145-RB

PolySwitch Resettable Devices Telecommunications & Networking Devices

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TE

TRF250-145T

PolySwitch Resettable Devices Telecommunications & Networking Devices

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MACOM

TRF250-145T

PTC Resettable Fuse, Through Hole Mount, RADIAL LEADED, ROHS COMPLIANT

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
LITTELFUSE

TRF250-145T-2

PTC Thermistor, Through Hole Mount, RADIAL LEADED, ROHS COMPLIANT

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
LITTELFUSE

TRF250-145U

Overcurrent Protection Device

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TE

TRF250-145U

PolySwitch Resettable Devices Telecommunications & Networking Devices

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MACOM

TRF250-145U-2

PolySwitch Resettable Devices Telecommunications & Networking Devices

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TE

TRF250-145US-B-0.5

PTC Resettable Fuse, Through Hole Mount, RADIAL LEADED, ROHS COMPLIANT

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
LITTELFUSE