VS304-31 [TE]

VERTICAL LIQUID LEVEL SWITCHES;
VS304-31
型号: VS304-31
厂家: TE CONNECTIVITY    TE CONNECTIVITY
描述:

VERTICAL LIQUID LEVEL SWITCHES

文件: 总6页 (文件大小:210K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
te.com  
VERTICAL  
LIQUID LEVEL SWITCHES  
VS Series  
High- or low-level switching  
N.O./N.C. SPST or SPDT outputs  
Mounted on the top/bottom wall of a tank  
Certified reed switch (UL component listed)  
Many different configurations available  
The VS series of point liquid level switches demonstrates a high  
degree of reliability due to the use of non-reactive wetted components  
and a unique reed switch designed specifically for level sensing  
applications. The sensor utilizes a moving float with an embedded  
magnet to activate a reed switch located in the sensor body. As the  
liquid level raises the float, it moves into close proximity to the reed  
switch and actuates it to give an open contact or closed contact  
switch indication.  
Features  
Voltage rating up to 250VAC  
Current rating up to 1.0 amp  
Compact design and low profile  
Optional cable lengths  
Includes mounting hardware  
The reliability of this sensor results from a very simple operating  
principle, a single moving part, media compatible wetted materials,  
and a unique reed switch design that has a UL recognized component  
certification.  
Applications  
Water and fuel storage tanks  
Full and/or empty detection  
Pump on/off controls  
The sensor mounts into the top or bottom wall of a liquid storage tank  
using either a 1/2” NPT or M16 x 2.0 threaded fitting. The M16 mount  
is available in either an internal or external configuration. The output  
is a simple N.O. or N.C. SPST, or SPDT reed switch that utilizes  
Ruthenium contact points for reliability. Changing from a N.O. output  
to a N.C. output is done by removing the float and reattaching it in an  
inverted orientation. This change can be done in the field. Electrical  
outputs are a single pair or three wires with PVC insulation and  
optional lengths of 0.5 m or 2.0 m.  
Marine bilge and ballast tanks  
Flood detection and prevention  
Coolant level indication  
Livestock watering tanks  
Irrigation systems  
Water treatment plants  
Waste water tanks  
CLICK HERE  
CONNECT WITH A SPECIALIST  
Page 1  
TE CONNECTIVITY SENSORS /// VS SERIES  
10/2020  
LIQUID LEVEL SWITCH  
VS SERIES  
Absolute Maximum Ratings (1)  
Model  
Type  
Parameter  
Min  
Max  
Units  
Notes/Conditions  
DC contact voltage (SPST)  
DC contact current (SPST)  
RMS contact voltage (SPST)  
RMS contact current (SPST)  
DC contact voltage (SPST)  
DC contact current (SPST)  
RMS contact voltage (SPST)  
RMS contact current (SPST)  
DC contact voltage (SPDT)  
DC contact current (N.O. SPDT)  
DC contact current (N.C. SPDT)  
RMS contact voltage (SPDT)  
RMS contact current (SPDT)  
Operating and storage temperature  
Fitting pressure  
100  
1
V
A
VSx01  
VSx09  
VSx04  
Do not exceed 15W  
120  
1
V
A
200  
1.0  
V
A
Do not exceed 70W  
250  
1.0  
V
A
170  
0.4  
V
A
0.125  
125  
0.125  
130  
4.7  
A
Do not exceed 5.0W  
Internal tank pressure  
V
A
-30  
-1.0  
1.0  
1.0  
°C  
Bar  
mm  
mm  
Tank wall thickness (Internal mount)  
Tank wall thickness (External mount)  
10  
4.0  
(1) Maximum limits the device will withstand without damage  
TE CONNECTIVITY SENSORS /// VS SERIES  
10/2020  
Page 2  
LIQUID LEVEL SWITCH  
VS SERIES  
Product Specifications  
Parameter  
Mounting Orientation  
Fitting  
Details & Options  
Top/bottom entry  
Internal or External  
N.C. when float at bottom stop (SPST)  
N.O. when float is inverted (SPST)  
Switch Operation  
Contact Forms  
Form A (SPST) or Form C (SPDT)  
Contact Material  
Contact resistance (max)  
Housing and Float Material  
Cable Description  
Shock  
Ruthenium  
250 mΩ (SPST)  
Glass filled nylon 6.6 (better for oil, fuel, non-ionic liquids)  
Glass filled polypropylene (better for aqueous media and solutions)  
22 AWG 16/0.2mm PVC insulated, UL/CSA/BS6361  
±50g 11ms half sign duration  
Vibration  
±35g 0 – 500Hz  
Ambient Humidity  
Ingress Protection  
Approvals & Certifications  
0 – 95% RH (non-condensing)  
IP68 (wetted surfaces) IP65 (non-wetted surfaces)  
UL file E98428  
TE CONNECTIVITY SENSORS /// VS SERIES  
10/2020  
Page 3  
LIQUID LEVEL SWITCH  
VS SERIES  
Outline Dimensions  
Schematic  
TE CONNECTIVITY SENSORS /// VS SERIES  
10/2020  
Page 4  
LIQUID LEVEL SWITCH  
VS SERIES  
Mounting Orientations  
Top Mount  
Bottom Mount  
Condition Switch (SPST)  
Condition Switch (SPST)  
No liquid  
Liquid  
Closed  
Open  
No liquid  
Liquid  
Open  
Closed  
Application Information  
The versatile design of the VCS series level sensor provides four different mounting and operating  
modes. The sensor can mount at either the top or bottom of a liquid storage tank. In either position,  
the float can be oriented to provide a N.O. or N.C. contact. Because the magnet is positioned at one  
end of the float, it can be removed from the body, turned upside down, and reinstalled to provide any of  
the four configurations shown below.  
To remove and re-orient the float, gently squeeze the retainer clips at the end of the sensor and slide  
the float off the body. Reinstall the float by sliding it back over the stem ensuring that it passes the clips  
and allows them to return to their original position.  
TE CONNECTIVITY SENSORS /// VS SERIES  
10/2020  
Page 5  
LIQUID LEVEL SWITCH  
VS SERIES  
Ordering Information  
Model Number  
VS __ __ __ __ __ __  
-
Material (body + float)  
Seal Material Options  
3
8
Glass-filled nylon 6.6  
Blank Silicone  
Glass-filled polypropylene  
N
Nitrile  
Cable Length Options  
Switch Options  
1
2
0.5m Single insulated PVC  
2.0m Single insulated PVC  
01  
04  
09  
Form A (N.O. SPST)  
Form C (SPDT)  
Form A (N.O. SPST)  
Fitting Options  
1
2
3
5
Internal M16  
External M16  
½” NPT  
Universal fitting kit (Options 1 & 2)  
CLICK HERE  
CONNECT WITH A SPECIALIST  
NORTH AMERICA  
Tel +1 800 522 6752  
EUROPE  
Tel +31 73 624 6999  
ASIA  
Tel +86 0400 820 6015  
te.com/sensors  
TE Connectivity, TE, TE Connectivity (logo) and Every Connection Counts are trademarks. All other logos, products and/or company names referred to herein might be  
trademarks of their respective owners  
The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE  
Connectivity makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity‘s obligations shall only be as  
set forth in TE Connectivity‘s Standard Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or  
consequential damages arising out of the sale, resale, use or misuse of the product. Users of TE Connectivity products should make their own evaluation to determine  
the suitability of each such product for the specific application.  
© 2020 TE Connectivity Corporation. All Rights Reserved.  
10/2020  
TE CONNECTIVITY SENSORS /// VS SERIES  
10/2020  

相关型号:

VS304-31N

VERTICAL LIQUID LEVEL SWITCHES

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TE

VS304-32

VERTICAL LIQUID LEVEL SWITCHES

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TE

VS304-32N

VERTICAL LIQUID LEVEL SWITCHES

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TE

VS304-51

VERTICAL LIQUID LEVEL SWITCHES

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TE

VS304-51N

VERTICAL LIQUID LEVEL SWITCHES

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TE

VS304-52

VERTICAL LIQUID LEVEL SWITCHES

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TE

VS304-52N

VERTICAL LIQUID LEVEL SWITCHES

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TE

VS309-11

VERTICAL LIQUID LEVEL SWITCHES

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TE

VS309-11N

VERTICAL LIQUID LEVEL SWITCHES

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TE

VS309-12

VERTICAL LIQUID LEVEL SWITCHES

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TE

VS309-12N

VERTICAL LIQUID LEVEL SWITCHES

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TE

VS309-21

VERTICAL LIQUID LEVEL SWITCHES

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TE