W67-X3Q5-20 [TE]
Magnetic Hydraulic Circuit Breakers; 电磁液压断路器型号: | W67-X3Q5-20 |
厂家: | TE CONNECTIVITY |
描述: | Magnetic Hydraulic Circuit Breakers |
文件: | 总6页 (文件大小:147K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
W6/W9 series
Magnetic Hydraulic
Circuit Breakers
Typical Resistance and Impedance
DC
Features
50/60 Hz.
Impedance
(Ohms)
90
400 Hz.
Impedance
(Ohms)
180
• Designed for the international market. UL Recognized, CSA Certified,
and VDE approved.
• Ratings to 50 amps.
Current
(Amps)
0.2
Resistance
(Ohms)
90
• Heavy duty #10-32 stud connections. (W9)
• Optional 10 amp auxiliary switch.
• Optional snap-in mounting. (W6)
• Several delay curve options.
1.0
2.0
5.0
10.0
20.0
30.0
40.0
50.0
1.2
0.28
0.04
0.013
0.004
0.0027
0.002
0.0015
1.2
0.28
0.04
0.013
0.005
0.004
0.002
0.0015
2.0
0.50
0.05
0.025
0.0065
0.004
0.003
• Trip-free operation.
0.0025
Tolerance: 0.1 - 4.99 15%; 5 - 9.99 20%; 10 - 15 25%; 16 - 30 50%.
Mechanical/Environmental Data
Operating Temperature: -40°C to +85°C.
Humidity: Meets requirements of Mil-STD-202 method 103.
Shock: Tested per Mil-STD-202, method 213, test condition C
(100g @ 6 ms).
Vibration:Tested per Mil-STD-202, method 201, 10-55 Hz., 0.06" (1.52mm)
total excursion in 2 planes.
Agency Approvals
UL: Recognized as Supplementary Protector under UL 1077. File
E69543.
CSA: Certified as a Supplementary Protector. File LR15734.
VDE: Approved to VDE 0642/EN 60 934 (Circuit Breakers for Equipment)
License No. 73782.
Fungus And Moisture Resistance:Special moisture resistant finish
applied to all ferrous parts.
Plastic parts are made of inherently
fungus resistant material.
Electrical Data
Marking: W6 units have ON and OFF molded on the rocker of rocker
actuated units (rocker actuated VDE units have international
“1” and “0”). W9 units have ON and OFF molded into the area
at the base of the toggle. International “1” and “0” symbols are
marked on the toggle for both W6 and W9.
Mounting: Panel mounted units are mounted with two #6-32 screws
from the front of the panel. Metric models for use with M3 x
0.5 screws are available. Units with snap-in mounting option
snap through the front of the panel. To maintain published
performance specifications, units should not be mounted
more than 90° from their normal upright position.
Weight: Approximately 2.5 ounces per pole.
Auxiliary Switch: See Auxiliary Switch Ratings Table 2 for details.
Calibration: Breakers will hold 100% of rated current. Breakers may trip
between 101% and 124% of rated load (149% for 400 Hz.
units and 134% for AC/DC units). Breakers must trip at
125% of rated load and above (150% for 400 Hz. units and
135% for AC/DC units).
Dielectric Strength: 50/60 or 400 Hz., 1500V: DC, 1100V.
Insulation Resistance: 100 Megohms at 500VDC.
Endurance: 10,000 on/off cycles - 6000 at rated load, 4000 at no load.
Units tested at six cycles per minute, 1 second on and 9
seconds off at 25°C ambient.
Approvals and Ratings Table 1
W6 Series
UL/CSA (All Circuit Functions)
W6 Series
VDE (Circuit Function X)
Current
Phase
Interrupting
Rating
(Amps)
Current
Phase
Interrupting
Maximum
Voltage
Frequency
(Hz)
Capacity
(Amps)
Maximum
Voltage
Frequency
(Hz)
Rating
Capacity
(Amps)
(Amps)
65
277
DC
50/60
50/60
50/60
400
-
0.2 - 50
0.2 - 20
21 - 50
0.2 - 20
0.2 - 20
21 - 50
0.2 - 20
2,000
5,000
2,500
5,000
2,500
1,250
2,500
65
250
DC
-
1
0.2-50
0.2-30
31-50
2,000
5,000
2,000
5,000
1
50/60
50/60
50/60
277
1
250
1
277/480
250
250
250
3Ø-Wye
415/240
3Ø
0.2-30
1
1
400
400
3Ø-Wye
W9 Series
UL/CSA (All Circuit Functions)
W9 Series
VDE (Circuit Function X)
Current
Phase
Interrupting
Rating
(Amps)
Current
Phase
Interrupting
Maximum
Voltage
Frequency
(Hz)
Capacity
(Amps)
Maximum
Voltage
Frequency
(Hz)
Rating
Capacity
(Amps)
(Amps)
65
277
277/480
250
250
DC
50/60
50/60
400
-
0.2 - 50
0.2 - 50
0.2 - 20
0.2 - 50
0.2 - 50
2,000
5,000
5,000
2,500
2,500
65
250
DC
-
1
0.2-50
0.2-30
31-50
2,000
5,000
2,000
5,000
1
50/60
50/60
50/60
3Ø-Wye
1
3Ø-Wye
250
1
415/240
3Ø
0.2-30
400
Approvals and Ratings Table 2
UL/CSA
VDE
Switch
Number
Voltage
50/60 Hz.
Current
(Amps)
Terminals
WxTxL
Switch
Number
Voltage
50/60 Hz.
Current
(Amps)
Terminals
WxTxL
A
125
10
.093 x .020 x .250
(2.36 x .51 x 6.40)
V1
V2
V3
250
250
250
10
5
0.1
.110 x .020 x .280
(2.79 x .51 x 7.11)
Time vs. Current Trip Curves For W6 Series and W9 Series
AC 50/60 Hz.
DC & 50/60 Hz.
400 Hz.
CURVE 0 NON-TIME DELAY
CURVE 2 AC VOLTAGE 50/60 Hz.
CURVE 3 AC VOLTAGE 50/60 Hz.
10,000
1000
100
10
10,000
1000
100
10
10,000
1000
100
10
TRIPTIMES
OVERLOAD @ 50/60 Hz. & DC @ 400 Hz.
OVERLOAD TRIPTIMES
(SEC.)
OVERLOAD TRIPTIMES
(SEC.)
125%
200%
400%
600%
800%
1000%
10 - 150
2.2 - 20
.2 - 2
125%
150%
200%
400%
600%
800%
100 ms max.
55 ms max.
30 ms max.
15 ms max.
12 ms max.
12 ms max.
MayTrip
125%
200%
400%
600%
800%
1000%
1 - 15
.15 - 1.5
.03 - .25
100 ms max.
30 ms max.
15 ms max.
12 ms max.
12 ms max.
.03 - .75
.007 - .15
.005 - .04
.007 - .15
.003 - .08
.003 - .04
1
1
1
.1
.1
.1
.01
.01
.01
.001
0
.001
0
.001
0
100 200 300 400 500 600 700 800 900 1000 1100 1200
100 200 300 400 500 600 700 800 900 1000 1100 1200
100 200 300 400 500 600 700 800 900 1000 1100 1200
125 150
125 150
125 150
LOAD CURRENT AS A PERCENT
LOAD CURRENT AS A PERCENT
LOAD CURRENT AS A PERCENT
OF BREAKER RATING
OF BREAKER RATING
OF BREAKER RATING
MOTOR START
CURVE 13 HIGH INRUSH 50/60 Hz.
CURVE 12 HIGH INRUSH 50/60 Hz.
CURVE 10 HIGH INRUSH 50/60 Hz. AC
10,000
1000
100
10
10,000
1000
100
10
10,000
1000
100
10
OVERLOAD TRIPTIMES
OVERLOAD TRIPTIMES
(SEC.)
OVERLOAD TRIPTIMES
(SEC.)
(SEC.)
125%
200%
400%
600%
800%
1000%
40 - 500
9 - 100
2 - 20
125%
200%
400%
600%
800%
1000%
10 - 150
3 - 25
.5 - 2.5
.15 - 1
.015 - .7
.009 - .35
125%
200%
400%
600%
800%
1000%
.8 - 30
.15 - 2.5
.03 - .3
.02 - .15
.009 - .12
.009 - .09
.8 - 10
.1 - 4.5
.009 - 2
1
1
1
.1
.1
.1
.01
.01
.01
.001
0
.001
0
.001
0
100 200 300 400 500 600 700 800 900 1000 1100 1200
100 200 300 400 500 600 700 800 900 1000 1100 1200
100 200 300 400 500 600 700 800 900 1000 1100 1200
125 150
125 150
125 150
LOAD CURRENT AS A PERCENT
LOAD CURRENT AS A PERCENT
LOAD CURRENT AS A PERCENT
OF BREAKER RATING
OF BREAKER RATING
OF BREAKER RATING
DC
10,000
1000
100
10
CURVE 3 DC VOLTAGE
CURVE 53 DC HIGH INRUSH
CURVE 2 DC VOLTAGE
10,000
1000
100
10
10,000
1000
100
10
OVERLOAD TRIPTIMES
OVERLOAD TRIPTIMES
(SEC.)
OVERLOAD TRIPTIMES
(SEC.)
(SEC.)
125%
200%
400%
600%
800%
1000%
80 - 700
15 - 150
2 - 20
125%
200%
400%
600%
800%
1000%
.6 - 7
.16 - 1.5
.03 - .25
.01 - .13
.004 - .05
.003 - .015
125%
200%
400%
600%
800%
1000%
2 - 55
.60 - 8
.1 - 1.5
.02 - .5
.004 - .05
.004 - .025
.70 - 10
.10 - 3
.01 - .1
1
1
1
.1
.1
.1
.01
.01
.01
.001
0
.001
0
.001
0
100 200 300 400 500 600 700 800 900 1000 1100 1200
100 200 300 400 500 600 700 800 900 1000 1100 1200
100 200 300 400 500 600 700 800 900 1000 1100 1200
125 150
125 150
125 150
LOAD CURRENT AS A PERCENT
LOAD CURRENT AS A PERCENT
LOAD CURRENT AS A PERCENT
OF BREAKER RATING
OF BREAKER RATING
OF BREAKER RATING
AC/DC
AC 400 Hz.
CURVE 34 DC, 50/60 Hz. STANDARD DELAY
CURVE 2 AC VOLTAGE 400 Hz.
CURVE 3 AC VOLTAGE 400 Hz.
10,000
1000
100
10
10,000
1000
100
10
10,000
1000
100
10
OVERLOAD TRIPTIMES
(SEC.)
OVERLOAD TRIPTIMES
OVERLOAD TRIPTIMES
(SEC.)
(SEC.)
135%
200%
400%
600%
800%
1000%
1 - 90
.60 - 20
.095 - 2
.02 - .95
.002 - .45
.002 - .09
150%
200%
400%
600%
800%
1000%
.55 - 5.5
.18 - 2
.02 - .2
.006 - .075
.004 - .05
.004 - .035
150%
200%
400%
600%
800%
1000%
5 - 60
2.2 - 20
.3 - 3.2
.01 - .17
.006 - .06
.005 - .045
1
1
1
.1
.1
.1
.01
.01
.01
.001
0
.001
0
.001
0
100 200 300 400 500 600 700 800 900 1000 1100 1200
100 200 300 400 500 600 700 800 900 1000 1100 1200
100 200 300 400 500 600 700 800 900 1000 1100 1200
125 150
135
125 150
LOAD CURRENT AS A PERCENT
OF BREAKER RATING
125 150
LOAD CURRENT AS A PERCENT
LOAD CURRENT AS A PERCENT
OF BREAKER RATING
OF BREAKER RATING
Note:
For instantaneous curves for all voltages refer to Curve 0 Non-Time Delay under the AC 50/60 Hz. heading.
Pulse Tolerance Specifications
Pulse tolerance is defined as a single pulse of a half sine
wave (1/2 cycle or 8 milliseconds) that will not trip the
breaker. An inertia wheel for increased pulse tolerance is
available by specifying “P” after the time delay curve
number in the ordering information. The table at right lists
pulse tolerance values of standard and inertia delay models.
Pulse Tolerance Value
Inertia
Time
Delay
Curve
Voltage
Standard
Delay
2
3
10
12
13
7.5
6
18
18
18
18
18
30
30
30
AC
50/60 Hz.
AC
400 Hz.
2
3
6.5
5.5
18
18
To determine pulse tolerance multiply breaker rating by value in table. For
example, a 2A breaker with time delay curve 3 has a standard pulse tolerance
of 12A (2A x 6). The same breaker with an inertia delay has a pulse tolerance
of 36A (2A x 18).
Ordering Information
W6 Series
Typical Part No. B
2-
20
Q
67- X
2
W
1
1. Circuit Breaker Mounting:
W = #6-32 mounting threads.
M = M3.0 x 0.5 mounting threads.
X = Snap-in mounting. (Not available in rocker actuated models.)
2. Number of Poles:
67 = Single pole
68 = Two pole
69 = Three pole
X = Series trip
70 = Four pole
3. Circuit Function: (Only X is VDE approved)
A = Series trip with auxiliary switch (.093” QC)
4. Actuator: (One actuator per pole)
1 = Black toggle
2 = White toggle
3 = Black rocker
4 = White rocker
5 = Red rocker
6 = Grey rocker
9 = Red toggle
5. Termination:
Q = .250” QC (DIN 46 244) 25A Max. VDE
S = #8-32 screw
T = #10-32 screw
Note: “T” termination must be used for all ratings of 31 amps or above.
6. Maximum Line Voltage: (See Table 1 for current ranges)
UL/CSA 1 = 277VAC, 50/60 Hz.
VDE
1 = 250VAC, 415/240VAC
TYPES
2 = 277/480
3 = 250VAC, 400 Hz.
5 = 65VDC
TYPES 5 = 65VDC
7 = AC/DC 250VAC, 415/240VAC, 65VDC
(Delay curve 34 must be specified.)
7 = AC/DC 277VAC or 65VDC
(Delay curve 34 must be specified.)
7. Time Delay Curve:
0 = Instantaneous
2 = Standard delay
3 = Short delay
10 = AC high inrush (Motor start)
12 = AC high inrush version of #2
13 = AC high inrush version of #3
34 = Combination AC/DC standard delay
Notes: Curves may be specified with increased pulse tolerance for 1/2 cycle by
adding "P" after curve, See delay curve section for availability and details.
53 = DC high inrush
8. Amp Rating:
0.20
0.25
0.50
0.75
1.0
1.5
2.0
2.5
3.0
3.5
4.0
5.0
6.0
7.0
7.5
8.0
9.0
10.0
11.0
12.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
Consult factory for
other values.
9. VDE Approval: (See Table 2 for auxiliary switch ratings)
Blank = UL/CSA approved breaker
V = VDE approved breaker without auxiliary switch
V1 = VDE approved breaker with 10 amp VDE auxiliary switch
V2 = VDE approved breaker with 5 amp VDE auxiliary switch
V3 = VDE approved breaker with 0.1 amp VDE auxiliary switch
Stock Items - We recommend that our authorized distributors stock the following items for immediate delivery.
W67-A2Q12-5
W67-A2Q12-10
W67-X2Q10-3
W67-X2Q10-5
W67-X2Q12-2
W67-X2Q12-3
W67-X2Q12-5
W67-X2Q12-7
W67-X2Q12-10
W67-X2Q12-15
W67-X2Q12-20
W67-X2Q12-30
W67-X2Q13-1
W67-X2Q13-2
W67-X2Q13-3
W67-X2Q13-10
W67-X2Q13-15
W67-X2Q13-20
W67-X2Q13-25
W67-X2Q13-30
W67-X2Q50-5
W67-X2Q50-10
W67-X2Q52-5
W67-X2Q52-10
W67-X2Q52-15
W67-X2Q52-20
W67-X2Q52-30
W67-X2Q110-15
W67-X2Q110-20
W68-X2Q12-3
W68-X2Q12-5
W68-X2Q12-7
W68-X2Q12-10
W68-X2Q12-15
W68-X2Q12-20
W68-X2Q12-25
W68-X2Q12-30
W68-X2Q13-15
W68-X2Q110-10
W68-X2Q110-20
W69-X2Q12-5
W69-X2Q12-10
W69-X2Q12-15
W69-X2Q12-20
W69-X2Q12-25
W69-X2Q12-30
W69-X2Q110-20
W69-X2Q110-30
Ordering Information
W9 Series
Typical Part No. B
1
W
1
2- 20
91-
X
1. Circuit Breaker Mounting:
W = #6-32 mounting threads.
M = M3.0 x 0.5 mounting threads.
93 = Three pole
2. Number of Poles:
91 = Single pole
92 = Two pole
94 = Four pole
3. Circuit Function: (Only X is VDE approved)
A = Series trip with auxiliary switch (.093” QC)
X = Series trip
4. Actuator: (One actuator per pole):
1 = Black toggle
2 = White toggle
5. Maximum Line Voltage: (See Table 1 for current ranges)
UL/CSA 1 = 277VAC, 50/60 Hz.
VDE
1 = 250VAC, 415/240VAC
TYPES
2 = 277/480
3 = 250VAC, 400 Hz.
5 = 65VDC
TYPES 5 = 65VDC
7 = AC/DC 250VAC, 415/240VAC, 65VDC
(Delay curve 34 must be specified.)
7 = AC/DC 277VAC or 65VDC
(Delay curve 34 must be specified.)
6. Time Delay Curve:
0 = Instantaneous
2 = Standard delay
3 = Short delay
10 = AC high inrush (Motor start)
12 = AC high inrush version of #2
13 = AC high inrush version of #3
34 = Combination AC/DC standard delay
Notes: Curves may be specified with increased pulse tolerance for 1/2 cycle
by adding "P" after curve. See delay curve section for availability and details.
53 = DC high inrush
7. Amp Rating:
0.20
0.25
0.50
0.75
1.0
2.0
2.5
3.0
3.5
4.0
5.0
6.0
7.0
7.5
8.0
9.0
10.0
11.0
12.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
Consult factory for other values
1.5
8. VDE Approval: (See Table 2 for auxiliary switch ratings)
Blank = UL/CSA approved breaker
V = VDE approved breaker without auxiliary switch
V1 = VDE approved breaker with 10 amp VDE auxiliary switch
V2 = VDE approved breaker with 5 amp VDE auxiliary switch
V3 = VDE approved breaker with 0.1 amp VDE auxiliary switch
Stock Items - We recommend that our authorized distributors stock the following items for immediate delivery.
W91-X112-1
W91-X112-2
W91-X112-3
W91-X112-5
W91-X112-7
W91-X112-10
W91-X112-15
W91-X112-20
W91-X112-40
W91-X112-50
W91-X113-5
W91-X113-10
W91-X113-15
W91-X150-5
W91-X152-10
W91-X152-15
W91-X152-20
W91-X152-30
W91-X152-40
W91-X152-50
W91-X1110-20
W92-X112-1
W92-X112-2
W92-X112-3
W92-X112-5
W92-X112-7
W92-X112-10
W92-X112-15
W92-X112-20
W92-X112-25
W92-X112-30
W92-X112-40
W92-X112-50
W92-X113-15
W92-X113-20
W92-X1110-20
W92-X1110-30
W93-X112-5
W93-X112-10
W93-X112-15
W93-X112-20
W93-X112-25
W93-X112-30
W93-X112-40
W93-X112-50
W93-X1110-20
W93-X1110-30
Outline Dimensions - Toggle Actuator Models.
W6 Series
Panel Mounting Cutout
1.640
(41.66)
.245
(6.22)
.235
(5.97)
.750
(19.05)
Ø .625 +.010
-.000
15.88 +0.25
-0.00
1 PER POLE
LINE
LOAD
(
)
O
N
A
B
29°
1.660
(42.16)
1.530
(38.86)
30°
1.048
(26.62)
OFF
Ø .156
(3.96)
2.040
(51.82)
.67
(17.02)
[2 PLACES PER POLE]
W6 Series
1 Pole
2 Pole
3 Pole
4 Pole
Ø .590
(15.00)
1.500
(38.10)
2.250
(57.15)
.750
(19.05)
3.000
(76.20)
1.660
(42.16)
2.000
(50.80)
1.05
(26.67)
1.22
(31.00)
6.32TH'D. .14 (3.56) DP.TYP.
M3 X 0.5 OPTIONAL
Note:
Multi-pole models furnished
with separate handle tie hardware.
VDE Models
W/Screw Terminals
UL/CSA Models
W/Screw Terminals
UL/CSA/VDE Models
W/Aux. Switch
.235
(5.9)
2.032
(51.61)
2.38 “A” STYLE
(60.45)
.416
(10.57)
LINE
LINE
LINE
.827
(20.85)
C
1.058
(26.87)
1.530
(38.86)
NO
NC
LOAD
LOAD
LOAD
Notes:
1. Terminal protrusion dimensions are referenced from back of mounting panel.
2. Main terminals are male quick connect type .250 (6.35) wide x .031 (.79)
thick x .377 (9.58) long. Optional 8-32 x .250 (6.35) or 10-32 x .250 (6.35)
screw type.
3. Panel mounting cutout detail mtg. detail tol.: .005 (.13) unless noted. Add
additional cutouts to correspond to number of poles. Outline drawing
tolerance .015 (.38) unless noted. Dimensions in brackets ( ) are in millimeters.
Outline Dimensions - Rocker Actuator Models
W6 Series
1 Pole
2, 3 & 4 Pole
3.000
.805
(20.45)
1.640
(76.20)
(41.66)
.750
(19.05)
2.250
(57.15)
4
POLE
.390
(9.91)
1.500
.375
(9.53)
3
(38.10)
.180
(4.57)
POLE
2 POLE
LOAD
D
A
.388
(9.86)
1.530
(38.86)
2.000
(50.80)
1.30
(33.0)
ON
ON
OFF
ON
ON
ON
1.660
(42.16)
2.600
(66.04)
OFF
OFF
OFF
OFF
LINE
.235
(5.97)
.375
(9.53)
2.430
(61.72)
TAPPED FOR #6-32
M3 X 0.5 OPTIONAL
.750
(19.05)
.750
(19.05)
.750
(19.05)
Panel Mounting Cutout
VDE Rocker Marking
.750
(19.05)
.750
(19.05)
.750
(19.05)
.205
(5.21)
.375
(9.53)
.750
(19.05)
.375
(9.53)
1.250
Notes:
(31.75)
.388
(9.86)
1. Outline drawing tolerance .015 (.38) unless
noted. Dimensions in brackets ( ) are in
millimeters.
1.660
2.000
(50.80)
(42.16)
I
2.600
(66.04)
2. Mounting Detail Tol.: .005 (.13) unless noted
O
.750
1 POLE
2 POLE
Ø .156
(19.05)
1.500
(38.10)
2.250
(57.15)
3.000
(76.20)
(3.96)
TYP. 2
PER POLE
3 POLE
4 POLE
TAPPED FOR #6-32
M3 X 0.5 OPTIONAL
Outline Dimensions - Snap-in Mounted Models
W6 Series
1 Pole
2 Pole
3 Pole
1.640
(41.66)
.245
(6.22)
2.250
(57.15)
.750
(19.05)
1.500
(38.10)
.235
(5.97)
.128
(3.25)
O
N
ON
ON
ON
ON
ON
ON
1.110
(28.19)
29°
1.530
(38.86)
2.650
(67.31)
30°
OFF
OFF
OFF
OFF
OFF
OFF
OFF
2.040
(51.82)
.67
(17.02)
4 Pole
Panel Mounting Cutout
1 Pole
2 Pole
3 Pole
3.000
(76.20)
1.525
(38.7)
2.280
(57.9)
.770
(19.6)
3.040
(77.2)
ON
ON
ON
ON
2.187
(55.55)
OFF
OFF
OFF
OFF
Notes:
Mounting Detail Tol.: .005 (.13) unless noted
Panel Thickness: .047 (1.2) to .110 (2.8)
Outline Dimensions
W9 Series
Series Trip Model
Series Trip Model
.750
.375
(9.53)
.750
(19.05)
.750
(19.05)
1.845
(46.86)
(19.05)
.398
(10.77)
.281
.750
(19.05)
.375
(9.53)
.313
(7.95)
(7.14)
LINE
ON
ON ON
ON ON ON ON ON ON ON ON
OFF OFF OFF OFF OFF OFF OFF OFF
.218
(5.54)
29°
30°
1.438
(36.53)
1.940
2.065
(52.45)
2.50
(63.5)
(49.28)
OFF OFF
OFF
LOAD
2 POLE
1.500
(38.10)
1 POLE
.14
(3.56)
#10-32
STUDTERMINATION
2.10
2.250
(57.15)
3POLE
TAPPED #6-32 X .16 (4.06)
DEEP
M3 X 0.5 OPTIONAL
(53.34)
3.000
4 POLE
2.50
(64.00)
.74
(18.8)
(76.20)
Series Trip Model
Panel Mounting Cutout Detail
With Common Enclosed Auxiliary Switch
.750
(19.05)
.750
(19.05)
Notes:
2.46
(62.48)
1. Terminal protrusion
dimensions are referenced
from the back of the
mounting panel.
2. Mounting detail tolerance
.005 (13) unless noted.
3. Outline drawing tolerance
.015 (.38) unless noted.
Dimensions in brackets ( )
are in millimeters.
.750
(19.05)
.385
'A' STYLE
.732
(18.59)
.281
(7.14)
(9.78)
.907
(23.04)
LINE
C
1.450
(36.83)
2.065
(52.45)
1.940
(49.28)
NO
NC
LOAD
.76
(19.3)
1 POLE
2X Ø .156
(3.96)
PER POLE
1.52
2 POLE
3 POLE
4 POLE
2.50
(64.00)
(38.6)
2.28
(57.9)
3.04
(77.2)
Tyco Electronics
700 Westpark Drive
Peachtree City, GA 30269-1498
Specifications and availability subject to change without notice.
13C9699 Printed in U.S.A. IH/2-00