W69-X3S3-20 [TE]

Magnetic Hydraulic Circuit Breakers; 电磁液压断路器
W69-X3S3-20
型号: W69-X3S3-20
厂家: TE CONNECTIVITY    TE CONNECTIVITY
描述:

Magnetic Hydraulic Circuit Breakers
电磁液压断路器

断路器
文件: 总6页 (文件大小:147K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
W6/W9 series  
Magnetic Hydraulic  
Circuit Breakers  
Typical Resistance and Impedance  
DC  
Features  
50/60 Hz.  
Impedance  
(Ohms)  
90  
400 Hz.  
Impedance  
(Ohms)  
180  
• Designed for the international market. UL Recognized, CSA Certified,  
and VDE approved.  
• Ratings to 50 amps.  
Current  
(Amps)  
0.2  
Resistance  
(Ohms)  
90  
• Heavy duty #10-32 stud connections. (W9)  
• Optional 10 amp auxiliary switch.  
• Optional snap-in mounting. (W6)  
• Several delay curve options.  
1.0  
2.0  
5.0  
10.0  
20.0  
30.0  
40.0  
50.0  
1.2  
0.28  
0.04  
0.013  
0.004  
0.0027  
0.002  
0.0015  
1.2  
0.28  
0.04  
0.013  
0.005  
0.004  
0.002  
0.0015  
2.0  
0.50  
0.05  
0.025  
0.0065  
0.004  
0.003  
Trip-free operation.  
0.0025  
Tolerance: 0.1 - 4.99 15%; 5 - 9.99 20%; 10 - 15 25%; 16 - 30 50%.  
Mechanical/Environmental Data  
Operating Temperature: -40°C to +85°C.  
Humidity: Meets requirements of Mil-STD-202 method 103.  
Shock: Tested per Mil-STD-202, method 213, test condition C  
(100g @ 6 ms).  
Vibration:Tested per Mil-STD-202, method 201, 10-55 Hz., 0.06" (1.52mm)  
total excursion in 2 planes.  
Agency Approvals  
UL: Recognized as Supplementary Protector under UL 1077. File  
E69543.  
CSA: Certified as a Supplementary Protector. File LR15734.  
VDE: Approved to VDE 0642/EN 60 934 (Circuit Breakers for Equipment)  
License No. 73782.  
Fungus And Moisture Resistance:Special moisture resistant finish  
applied to all ferrous parts.  
Plastic parts are made of inherently  
fungus resistant material.  
Electrical Data  
Marking: W6 units have ON and OFF molded on the rocker of rocker  
actuated units (rocker actuated VDE units have international  
“1” and “0”). W9 units have ON and OFF molded into the area  
at the base of the toggle. International “1” and “0” symbols are  
marked on the toggle for both W6 and W9.  
Mounting: Panel mounted units are mounted with two #6-32 screws  
from the front of the panel. Metric models for use with M3 x  
0.5 screws are available. Units with snap-in mounting option  
snap through the front of the panel. To maintain published  
performance specifications, units should not be mounted  
more than 90° from their normal upright position.  
Weight: Approximately 2.5 ounces per pole.  
Auxiliary Switch: See Auxiliary Switch Ratings Table 2 for details.  
Calibration: Breakers will hold 100% of rated current. Breakers may trip  
between 101% and 124% of rated load (149% for 400 Hz.  
units and 134% for AC/DC units). Breakers must trip at  
125% of rated load and above (150% for 400 Hz. units and  
135% for AC/DC units).  
Dielectric Strength: 50/60 or 400 Hz., 1500V: DC, 1100V.  
Insulation Resistance: 100 Megohms at 500VDC.  
Endurance: 10,000 on/off cycles - 6000 at rated load, 4000 at no load.  
Units tested at six cycles per minute, 1 second on and 9  
seconds off at 25°C ambient.  
Approvals and Ratings Table 1  
W6 Series  
UL/CSA (All Circuit Functions)  
W6 Series  
VDE (Circuit Function X)  
Current  
Phase  
Interrupting  
Rating  
(Amps)  
Current  
Phase  
Interrupting  
Maximum  
Voltage  
Frequency  
(Hz)  
Capacity  
(Amps)  
Maximum  
Voltage  
Frequency  
(Hz)  
Rating  
Capacity  
(Amps)  
(Amps)  
65  
277  
DC  
50/60  
50/60  
50/60  
400  
-
0.2 - 50  
0.2 - 20  
21 - 50  
0.2 - 20  
0.2 - 20  
21 - 50  
0.2 - 20  
2,000  
5,000  
2,500  
5,000  
2,500  
1,250  
2,500  
65  
250  
DC  
-
1
0.2-50  
0.2-30  
31-50  
2,000  
5,000  
2,000  
5,000  
1
50/60  
50/60  
50/60  
277  
1
250  
1
277/480  
250  
250  
250  
3Ø-Wye  
415/240  
3Ø  
0.2-30  
1
1
400  
400  
3Ø-Wye  
W9 Series  
UL/CSA (All Circuit Functions)  
W9 Series  
VDE (Circuit Function X)  
Current  
Phase  
Interrupting  
Rating  
(Amps)  
Current  
Phase  
Interrupting  
Maximum  
Voltage  
Frequency  
(Hz)  
Capacity  
(Amps)  
Maximum  
Voltage  
Frequency  
(Hz)  
Rating  
Capacity  
(Amps)  
(Amps)  
65  
277  
277/480  
250  
250  
DC  
50/60  
50/60  
400  
-
0.2 - 50  
0.2 - 50  
0.2 - 20  
0.2 - 50  
0.2 - 50  
2,000  
5,000  
5,000  
2,500  
2,500  
65  
250  
DC  
-
1
0.2-50  
0.2-30  
31-50  
2,000  
5,000  
2,000  
5,000  
1
50/60  
50/60  
50/60  
3Ø-Wye  
1
3Ø-Wye  
250  
1
415/240  
3Ø  
0.2-30  
400  
Approvals and Ratings Table 2  
UL/CSA  
VDE  
Switch  
Number  
Voltage  
50/60 Hz.  
Current  
(Amps)  
Terminals  
WxTxL  
Switch  
Number  
Voltage  
50/60 Hz.  
Current  
(Amps)  
Terminals  
WxTxL  
A
125  
10  
.093 x .020 x .250  
(2.36 x .51 x 6.40)  
V1  
V2  
V3  
250  
250  
250  
10  
5
0.1  
.110 x .020 x .280  
(2.79 x .51 x 7.11)  
Time vs. Current Trip Curves For W6 Series and W9 Series  
AC 50/60 Hz.  
DC & 50/60 Hz.  
400 Hz.  
CURVE 0 NON-TIME DELAY  
CURVE 2 AC VOLTAGE 50/60 Hz.  
CURVE 3 AC VOLTAGE 50/60 Hz.  
10,000  
1000  
100  
10  
10,000  
1000  
100  
10  
10,000  
1000  
100  
10  
TRIPTIMES  
OVERLOAD @ 50/60 Hz. & DC @ 400 Hz.  
OVERLOAD TRIPTIMES  
(SEC.)  
OVERLOAD TRIPTIMES  
(SEC.)  
125%  
200%  
400%  
600%  
800%  
1000%  
10 - 150  
2.2 - 20  
.2 - 2  
125%  
150%  
200%  
400%  
600%  
800%  
100 ms max.  
55 ms max.  
30 ms max.  
15 ms max.  
12 ms max.  
12 ms max.  
MayTrip  
125%  
200%  
400%  
600%  
800%  
1000%  
1 - 15  
.15 - 1.5  
.03 - .25  
100 ms max.  
30 ms max.  
15 ms max.  
12 ms max.  
12 ms max.  
.03 - .75  
.007 - .15  
.005 - .04  
.007 - .15  
.003 - .08  
.003 - .04  
1
1
1
.1  
.1  
.1  
.01  
.01  
.01  
.001  
0
.001  
0
.001  
0
100 200 300 400 500 600 700 800 900 1000 1100 1200  
100 200 300 400 500 600 700 800 900 1000 1100 1200  
100 200 300 400 500 600 700 800 900 1000 1100 1200  
125 150  
125 150  
125 150  
LOAD CURRENT AS A PERCENT  
LOAD CURRENT AS A PERCENT  
LOAD CURRENT AS A PERCENT  
OF BREAKER RATING  
OF BREAKER RATING  
OF BREAKER RATING  
MOTOR START  
CURVE 13 HIGH INRUSH 50/60 Hz.  
CURVE 12 HIGH INRUSH 50/60 Hz.  
CURVE 10 HIGH INRUSH 50/60 Hz. AC  
10,000  
1000  
100  
10  
10,000  
1000  
100  
10  
10,000  
1000  
100  
10  
OVERLOAD TRIPTIMES  
OVERLOAD TRIPTIMES  
(SEC.)  
OVERLOAD TRIPTIMES  
(SEC.)  
(SEC.)  
125%  
200%  
400%  
600%  
800%  
1000%  
40 - 500  
9 - 100  
2 - 20  
125%  
200%  
400%  
600%  
800%  
1000%  
10 - 150  
3 - 25  
.5 - 2.5  
.15 - 1  
.015 - .7  
.009 - .35  
125%  
200%  
400%  
600%  
800%  
1000%  
.8 - 30  
.15 - 2.5  
.03 - .3  
.02 - .15  
.009 - .12  
.009 - .09  
.8 - 10  
.1 - 4.5  
.009 - 2  
1
1
1
.1  
.1  
.1  
.01  
.01  
.01  
.001  
0
.001  
0
.001  
0
100 200 300 400 500 600 700 800 900 1000 1100 1200  
100 200 300 400 500 600 700 800 900 1000 1100 1200  
100 200 300 400 500 600 700 800 900 1000 1100 1200  
125 150  
125 150  
125 150  
LOAD CURRENT AS A PERCENT  
LOAD CURRENT AS A PERCENT  
LOAD CURRENT AS A PERCENT  
OF BREAKER RATING  
OF BREAKER RATING  
OF BREAKER RATING  
DC  
10,000  
1000  
100  
10  
CURVE 3 DC VOLTAGE  
CURVE 53 DC HIGH INRUSH  
CURVE 2 DC VOLTAGE  
10,000  
1000  
100  
10  
10,000  
1000  
100  
10  
OVERLOAD TRIPTIMES  
OVERLOAD TRIPTIMES  
(SEC.)  
OVERLOAD TRIPTIMES  
(SEC.)  
(SEC.)  
125%  
200%  
400%  
600%  
800%  
1000%  
80 - 700  
15 - 150  
2 - 20  
125%  
200%  
400%  
600%  
800%  
1000%  
.6 - 7  
.16 - 1.5  
.03 - .25  
.01 - .13  
.004 - .05  
.003 - .015  
125%  
200%  
400%  
600%  
800%  
1000%  
2 - 55  
.60 - 8  
.1 - 1.5  
.02 - .5  
.004 - .05  
.004 - .025  
.70 - 10  
.10 - 3  
.01 - .1  
1
1
1
.1  
.1  
.1  
.01  
.01  
.01  
.001  
0
.001  
0
.001  
0
100 200 300 400 500 600 700 800 900 1000 1100 1200  
100 200 300 400 500 600 700 800 900 1000 1100 1200  
100 200 300 400 500 600 700 800 900 1000 1100 1200  
125 150  
125 150  
125 150  
LOAD CURRENT AS A PERCENT  
LOAD CURRENT AS A PERCENT  
LOAD CURRENT AS A PERCENT  
OF BREAKER RATING  
OF BREAKER RATING  
OF BREAKER RATING  
AC/DC  
AC 400 Hz.  
CURVE 34 DC, 50/60 Hz. STANDARD DELAY  
CURVE 2 AC VOLTAGE 400 Hz.  
CURVE 3 AC VOLTAGE 400 Hz.  
10,000  
1000  
100  
10  
10,000  
1000  
100  
10  
10,000  
1000  
100  
10  
OVERLOAD TRIPTIMES  
(SEC.)  
OVERLOAD TRIPTIMES  
OVERLOAD TRIPTIMES  
(SEC.)  
(SEC.)  
135%  
200%  
400%  
600%  
800%  
1000%  
1 - 90  
.60 - 20  
.095 - 2  
.02 - .95  
.002 - .45  
.002 - .09  
150%  
200%  
400%  
600%  
800%  
1000%  
.55 - 5.5  
.18 - 2  
.02 - .2  
.006 - .075  
.004 - .05  
.004 - .035  
150%  
200%  
400%  
600%  
800%  
1000%  
5 - 60  
2.2 - 20  
.3 - 3.2  
.01 - .17  
.006 - .06  
.005 - .045  
1
1
1
.1  
.1  
.1  
.01  
.01  
.01  
.001  
0
.001  
0
.001  
0
100 200 300 400 500 600 700 800 900 1000 1100 1200  
100 200 300 400 500 600 700 800 900 1000 1100 1200  
100 200 300 400 500 600 700 800 900 1000 1100 1200  
125 150  
135  
125 150  
LOAD CURRENT AS A PERCENT  
OF BREAKER RATING  
125 150  
LOAD CURRENT AS A PERCENT  
LOAD CURRENT AS A PERCENT  
OF BREAKER RATING  
OF BREAKER RATING  
Note:  
For instantaneous curves for all voltages refer to Curve 0 Non-Time Delay under the AC 50/60 Hz. heading.  
Pulse Tolerance Specifications  
Pulse tolerance is defined as a single pulse of a half sine  
wave (1/2 cycle or 8 milliseconds) that will not trip the  
breaker. An inertia wheel for increased pulse tolerance is  
available by specifying “P” after the time delay curve  
number in the ordering information. The table at right lists  
pulse tolerance values of standard and inertia delay models.  
Pulse Tolerance Value  
Inertia  
Time  
Delay  
Curve  
Voltage  
Standard  
Delay  
2
3
10  
12  
13  
7.5  
6
18  
18  
18  
18  
18  
30  
30  
30  
AC  
50/60 Hz.  
AC  
400 Hz.  
2
3
6.5  
5.5  
18  
18  
To determine pulse tolerance multiply breaker rating by value in table. For  
example, a 2A breaker with time delay curve 3 has a standard pulse tolerance  
of 12A (2A x 6). The same breaker with an inertia delay has a pulse tolerance  
of 36A (2A x 18).  
Ordering Information  
W6 Series  
Typical Part No. B  
2-  
20  
Q
67- X  
2
W
1
1. Circuit Breaker Mounting:  
W = #6-32 mounting threads.  
M = M3.0 x 0.5 mounting threads.  
X = Snap-in mounting. (Not available in rocker actuated models.)  
2. Number of Poles:  
67 = Single pole  
68 = Two pole  
69 = Three pole  
X = Series trip  
70 = Four pole  
3. Circuit Function: (Only X is VDE approved)  
A = Series trip with auxiliary switch (.093” QC)  
4. Actuator: (One actuator per pole)  
1 = Black toggle  
2 = White toggle  
3 = Black rocker  
4 = White rocker  
5 = Red rocker  
6 = Grey rocker  
9 = Red toggle  
5. Termination:  
Q = .250” QC (DIN 46 244) 25A Max. VDE  
S = #8-32 screw  
T = #10-32 screw  
Note: “T” termination must be used for all ratings of 31 amps or above.  
6. Maximum Line Voltage: (See Table 1 for current ranges)  
UL/CSA 1 = 277VAC, 50/60 Hz.  
VDE  
1 = 250VAC, 415/240VAC  
TYPES  
2 = 277/480  
3 = 250VAC, 400 Hz.  
5 = 65VDC  
TYPES 5 = 65VDC  
7 = AC/DC 250VAC, 415/240VAC, 65VDC  
(Delay curve 34 must be specified.)  
7 = AC/DC 277VAC or 65VDC  
(Delay curve 34 must be specified.)  
7. Time Delay Curve:  
0 = Instantaneous  
2 = Standard delay  
3 = Short delay  
10 = AC high inrush (Motor start)  
12 = AC high inrush version of #2  
13 = AC high inrush version of #3  
34 = Combination AC/DC standard delay  
Notes: Curves may be specified with increased pulse tolerance for 1/2 cycle by  
adding "P" after curve, See delay curve section for availability and details.  
53 = DC high inrush  
8. Amp Rating:  
0.20  
0.25  
0.50  
0.75  
1.0  
1.5  
2.0  
2.5  
3.0  
3.5  
4.0  
5.0  
6.0  
7.0  
7.5  
8.0  
9.0  
10.0  
11.0  
12.0  
15.0  
20.0  
25.0  
30.0  
35.0  
40.0  
45.0  
50.0  
Consult factory for  
other values.  
9. VDE Approval: (See Table 2 for auxiliary switch ratings)  
Blank = UL/CSA approved breaker  
V = VDE approved breaker without auxiliary switch  
V1 = VDE approved breaker with 10 amp VDE auxiliary switch  
V2 = VDE approved breaker with 5 amp VDE auxiliary switch  
V3 = VDE approved breaker with 0.1 amp VDE auxiliary switch  
Stock Items - We recommend that our authorized distributors stock the following items for immediate delivery.  
W67-A2Q12-5  
W67-A2Q12-10  
W67-X2Q10-3  
W67-X2Q10-5  
W67-X2Q12-2  
W67-X2Q12-3  
W67-X2Q12-5  
W67-X2Q12-7  
W67-X2Q12-10  
W67-X2Q12-15  
W67-X2Q12-20  
W67-X2Q12-30  
W67-X2Q13-1  
W67-X2Q13-2  
W67-X2Q13-3  
W67-X2Q13-10  
W67-X2Q13-15  
W67-X2Q13-20  
W67-X2Q13-25  
W67-X2Q13-30  
W67-X2Q50-5  
W67-X2Q50-10  
W67-X2Q52-5  
W67-X2Q52-10  
W67-X2Q52-15  
W67-X2Q52-20  
W67-X2Q52-30  
W67-X2Q110-15  
W67-X2Q110-20  
W68-X2Q12-3  
W68-X2Q12-5  
W68-X2Q12-7  
W68-X2Q12-10  
W68-X2Q12-15  
W68-X2Q12-20  
W68-X2Q12-25  
W68-X2Q12-30  
W68-X2Q13-15  
W68-X2Q110-10  
W68-X2Q110-20  
W69-X2Q12-5  
W69-X2Q12-10  
W69-X2Q12-15  
W69-X2Q12-20  
W69-X2Q12-25  
W69-X2Q12-30  
W69-X2Q110-20  
W69-X2Q110-30  
Ordering Information  
W9 Series  
Typical Part No. B  
1
W
1
2- 20  
91-  
X
1. Circuit Breaker Mounting:  
W = #6-32 mounting threads.  
M = M3.0 x 0.5 mounting threads.  
93 = Three pole  
2. Number of Poles:  
91 = Single pole  
92 = Two pole  
94 = Four pole  
3. Circuit Function: (Only X is VDE approved)  
A = Series trip with auxiliary switch (.093” QC)  
X = Series trip  
4. Actuator: (One actuator per pole):  
1 = Black toggle  
2 = White toggle  
5. Maximum Line Voltage: (See Table 1 for current ranges)  
UL/CSA 1 = 277VAC, 50/60 Hz.  
VDE  
1 = 250VAC, 415/240VAC  
TYPES  
2 = 277/480  
3 = 250VAC, 400 Hz.  
5 = 65VDC  
TYPES 5 = 65VDC  
7 = AC/DC 250VAC, 415/240VAC, 65VDC  
(Delay curve 34 must be specified.)  
7 = AC/DC 277VAC or 65VDC  
(Delay curve 34 must be specified.)  
6. Time Delay Curve:  
0 = Instantaneous  
2 = Standard delay  
3 = Short delay  
10 = AC high inrush (Motor start)  
12 = AC high inrush version of #2  
13 = AC high inrush version of #3  
34 = Combination AC/DC standard delay  
Notes: Curves may be specified with increased pulse tolerance for 1/2 cycle  
by adding "P" after curve. See delay curve section for availability and details.  
53 = DC high inrush  
7. Amp Rating:  
0.20  
0.25  
0.50  
0.75  
1.0  
2.0  
2.5  
3.0  
3.5  
4.0  
5.0  
6.0  
7.0  
7.5  
8.0  
9.0  
10.0  
11.0  
12.0  
15.0  
20.0  
25.0  
30.0  
35.0  
40.0  
45.0  
50.0  
Consult factory for other values  
1.5  
8. VDE Approval: (See Table 2 for auxiliary switch ratings)  
Blank = UL/CSA approved breaker  
V = VDE approved breaker without auxiliary switch  
V1 = VDE approved breaker with 10 amp VDE auxiliary switch  
V2 = VDE approved breaker with 5 amp VDE auxiliary switch  
V3 = VDE approved breaker with 0.1 amp VDE auxiliary switch  
Stock Items - We recommend that our authorized distributors stock the following items for immediate delivery.  
W91-X112-1  
W91-X112-2  
W91-X112-3  
W91-X112-5  
W91-X112-7  
W91-X112-10  
W91-X112-15  
W91-X112-20  
W91-X112-40  
W91-X112-50  
W91-X113-5  
W91-X113-10  
W91-X113-15  
W91-X150-5  
W91-X152-10  
W91-X152-15  
W91-X152-20  
W91-X152-30  
W91-X152-40  
W91-X152-50  
W91-X1110-20  
W92-X112-1  
W92-X112-2  
W92-X112-3  
W92-X112-5  
W92-X112-7  
W92-X112-10  
W92-X112-15  
W92-X112-20  
W92-X112-25  
W92-X112-30  
W92-X112-40  
W92-X112-50  
W92-X113-15  
W92-X113-20  
W92-X1110-20  
W92-X1110-30  
W93-X112-5  
W93-X112-10  
W93-X112-15  
W93-X112-20  
W93-X112-25  
W93-X112-30  
W93-X112-40  
W93-X112-50  
W93-X1110-20  
W93-X1110-30  
Outline Dimensions - Toggle Actuator Models.  
W6 Series  
Panel Mounting Cutout  
1.640  
(41.66)  
.245  
(6.22)  
.235  
(5.97)  
.750  
(19.05)  
Ø .625 +.010  
-.000  
15.88 +0.25  
-0.00  
1 PER POLE  
LINE  
LOAD  
(
)
O
N
A
B
29°  
1.660  
(42.16)  
1.530  
(38.86)  
30°  
1.048  
(26.62)  
OFF  
Ø .156  
(3.96)  
2.040  
(51.82)  
.67  
(17.02)  
[2 PLACES PER POLE]  
W6 Series  
1 Pole  
2 Pole  
3 Pole  
4 Pole  
Ø .590  
(15.00)  
1.500  
(38.10)  
2.250  
(57.15)  
.750  
(19.05)  
3.000  
(76.20)  
1.660  
(42.16)  
2.000  
(50.80)  
1.05  
(26.67)  
1.22  
(31.00)  
6.32TH'D. .14 (3.56) DP.TYP.  
M3 X 0.5 OPTIONAL  
Note:  
Multi-pole models furnished  
with separate handle tie hardware.  
VDE Models  
W/Screw Terminals  
UL/CSA Models  
W/Screw Terminals  
UL/CSA/VDE Models  
W/Aux. Switch  
.235  
(5.9)  
2.032  
(51.61)  
2.38 A” STYLE  
(60.45)  
.416  
(10.57)  
LINE  
LINE  
LINE  
.827  
(20.85)  
C
1.058  
(26.87)  
1.530  
(38.86)  
NO  
NC  
LOAD  
LOAD  
LOAD  
Notes:  
1. Terminal protrusion dimensions are referenced from back of mounting panel.  
2. Main terminals are male quick connect type .250 (6.35) wide x .031 (.79)  
thick x .377 (9.58) long. Optional 8-32 x .250 (6.35) or 10-32 x .250 (6.35)  
screw type.  
3. Panel mounting cutout detail mtg. detail tol.: .005 (.13) unless noted. Add  
additional cutouts to correspond to number of poles. Outline drawing  
tolerance .015 (.38) unless noted. Dimensions in brackets ( ) are in millimeters.  
Outline Dimensions - Rocker Actuator Models  
W6 Series  
1 Pole  
2, 3 & 4 Pole  
3.000  
.805  
(20.45)  
1.640  
(76.20)  
(41.66)  
.750  
(19.05)  
2.250  
(57.15)  
4
POLE  
.390  
(9.91)  
1.500  
.375  
(9.53)  
3
(38.10)  
.180  
(4.57)  
POLE  
2 POLE  
LOAD  
D
A
.388  
(9.86)  
1.530  
(38.86)  
2.000  
(50.80)  
1.30  
(33.0)  
ON  
ON  
OFF  
ON  
ON  
ON  
1.660  
(42.16)  
2.600  
(66.04)  
OFF  
OFF  
OFF  
OFF  
LINE  
.235  
(5.97)  
.375  
(9.53)  
2.430  
(61.72)  
TAPPED FOR #6-32  
M3 X 0.5 OPTIONAL  
.750  
(19.05)  
.750  
(19.05)  
.750  
(19.05)  
Panel Mounting Cutout  
VDE Rocker Marking  
.750  
(19.05)  
.750  
(19.05)  
.750  
(19.05)  
.205  
(5.21)  
.375  
(9.53)  
.750  
(19.05)  
.375  
(9.53)  
1.250  
Notes:  
(31.75)  
.388  
(9.86)  
1. Outline drawing tolerance .015 (.38) unless  
noted. Dimensions in brackets ( ) are in  
millimeters.  
1.660  
2.000  
(50.80)  
(42.16)  
I
2.600  
(66.04)  
2. Mounting Detail Tol.: .005 (.13) unless noted  
O
.750  
1 POLE  
2 POLE  
Ø .156  
(19.05)  
1.500  
(38.10)  
2.250  
(57.15)  
3.000  
(76.20)  
(3.96)  
TYP. 2  
PER POLE  
3 POLE  
4 POLE  
TAPPED FOR #6-32  
M3 X 0.5 OPTIONAL  
Outline Dimensions - Snap-in Mounted Models  
W6 Series  
1 Pole  
2 Pole  
3 Pole  
1.640  
(41.66)  
.245  
(6.22)  
2.250  
(57.15)  
.750  
(19.05)  
1.500  
(38.10)  
.235  
(5.97)  
.128  
(3.25)  
O
N
ON  
ON  
ON  
ON  
ON  
ON  
1.110  
(28.19)  
29°  
1.530  
(38.86)  
2.650  
(67.31)  
30°  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
2.040  
(51.82)  
.67  
(17.02)  
4 Pole  
Panel Mounting Cutout  
1 Pole  
2 Pole  
3 Pole  
3.000  
(76.20)  
1.525  
(38.7)  
2.280  
(57.9)  
.770  
(19.6)  
3.040  
(77.2)  
ON  
ON  
ON  
ON  
2.187  
(55.55)  
OFF  
OFF  
OFF  
OFF  
Notes:  
Mounting Detail Tol.: .005 (.13) unless noted  
Panel Thickness: .047 (1.2) to .110 (2.8)  
Outline Dimensions  
W9 Series  
Series Trip Model  
Series Trip Model  
.750  
.375  
(9.53)  
.750  
(19.05)  
.750  
(19.05)  
1.845  
(46.86)  
(19.05)  
.398  
(10.77)  
.281  
.750  
(19.05)  
.375  
(9.53)  
.313  
(7.95)  
(7.14)  
LINE  
ON  
ON ON  
ON ON ON ON ON ON ON ON  
OFF OFF OFF OFF OFF OFF OFF OFF  
.218  
(5.54)  
29°  
30°  
1.438  
(36.53)  
1.940  
2.065  
(52.45)  
2.50  
(63.5)  
(49.28)  
OFF OFF  
OFF  
LOAD  
2 POLE  
1.500  
(38.10)  
1 POLE  
.14  
(3.56)  
#10-32  
STUDTERMINATION  
2.10  
2.250  
(57.15)  
3POLE  
TAPPED #6-32 X .16 (4.06)  
DEEP  
M3 X 0.5 OPTIONAL  
(53.34)  
3.000  
4 POLE  
2.50  
(64.00)  
.74  
(18.8)  
(76.20)  
Series Trip Model  
Panel Mounting Cutout Detail  
With Common Enclosed Auxiliary Switch  
.750  
(19.05)  
.750  
(19.05)  
Notes:  
2.46  
(62.48)  
1. Terminal protrusion  
dimensions are referenced  
from the back of the  
mounting panel.  
2. Mounting detail tolerance  
.005 (13) unless noted.  
3. Outline drawing tolerance  
.015 (.38) unless noted.  
Dimensions in brackets ( )  
are in millimeters.  
.750  
(19.05)  
.385  
'A' STYLE  
.732  
(18.59)  
.281  
(7.14)  
(9.78)  
.907  
(23.04)  
LINE  
C
1.450  
(36.83)  
2.065  
(52.45)  
1.940  
(49.28)  
NO  
NC  
LOAD  
.76  
(19.3)  
1 POLE  
2X Ø .156  
(3.96)  
PER POLE  
1.52  
2 POLE  
3 POLE  
4 POLE  
2.50  
(64.00)  
(38.6)  
2.28  
(57.9)  
3.04  
(77.2)  
Tyco Electronics  
700 Westpark Drive  
Peachtree City, GA 30269-1498  
Specifications and availability subject to change without notice.  
13C9699 Printed in U.S.A. IH/2-00  

相关型号:

W69-X3S5-20

Magnetic Hydraulic Circuit Breakers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TE

W69-X3T1-20

Magnetic Hydraulic Circuit Breakers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TE

W69-X3T3-20

Magnetic Hydraulic Circuit Breakers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TE

W6A80-8PG-513

CABLE-END CONNECTOR 2-16 6-26 PIN CONTACTS MINI-CON-X POWER/SIGNAL

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC

W6A80-8PG-516

CABLE-END CONNECTOR 2-16 6-26 PIN CONTACTS MINI-CON-X POWER/SIGNAL

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC

W6A80-8PG-519

CABLE-END CONNECTOR 2-16 6-26 PIN CONTACTS MINI-CON-X POWER/SIGNAL

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC

W6A80-8PG-522

CABLE-END CONNECTOR 2-16 6-26 PIN CONTACTS MINI-CON-X POWER/SIGNAL

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC

W6A80-8PG-528

CABLE-END CONNECTOR 2-16 6-26 PIN CONTACTS MINI-CON-X POWER/SIGNAL

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC

W6A80-8SG-513

2-16 6-26 SOCKET CONTACTS MINI-CON-X POWER/SIGNAL

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC

W6A80-8SG-516

2-16 6-26 SOCKET CONTACTS MINI-CON-X POWER/SIGNAL

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC

W6A80-8SG-519

2-16 6-26 SOCKET CONTACTS MINI-CON-X POWER/SIGNAL

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC

W6A80-8SG-522

2-16 6-26 SOCKET CONTACTS MINI-CON-X POWER/SIGNAL

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC