5962-8995601LA [TI]

具有三态输出的八路总线寄存收发器 | JT | 24 | -55 to 125;
5962-8995601LA
型号: 5962-8995601LA
厂家: TEXAS INSTRUMENTS    TEXAS INSTRUMENTS
描述:

具有三态输出的八路总线寄存收发器 | JT | 24 | -55 to 125

驱动 总线驱动器 总线收发器
文件: 总18页 (文件大小:272K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
SN54ALS646, SN54ALS648, SN54AS646  
SN74ALS646A, SN74ALS648A, SN74AS646, SN74AS648  
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS  
SDAS039F – DECEMBER 1983 – REVISED JANUARY 1995  
SN54ALS646, SN54ALS648, SN54AS646 . . . JT PACKAGE  
Independent Registers for A and B Buses  
Multiplexed Real-Time and Stored Data  
Choice of True or Inverting Data Paths  
SN74ALS646A, SN74ALS648A, SN74AS646,  
SN74AS648 . . . DW OR NT PACKAGE  
(TOP VIEW)  
Choice of 3-State or Open-Collector  
CLKAB  
SAB  
DIR  
A1  
A2  
A3  
A4  
A5  
A6  
A7  
A8  
GND  
V
CC  
1
24  
23  
22  
21  
20  
19  
18  
17  
16  
15  
14  
13  
Outputs  
CLKBA  
SBA  
OE  
B1  
B2  
B3  
B4  
B5  
B6  
B7  
2
Package Options Include Plastic  
Small-Outline (DW) Packages, Ceramic  
Chip Carriers (FK), and Standard Plastic  
(NT) and Ceramic (JT) 300-mil DIPs  
3
4
5
6
7
DEVICE  
OUTPUT  
3 state  
LOGIC  
True  
8
SN54ALS646, SN74ALS646A, AS646  
SN54ALS648, SN74ALS648A, SN74AS648  
9
3 state  
Inverting  
10  
11  
12  
description  
B8  
These devices consist of bus-transceiver circuits  
with 3-state or open-collector outputs, D-type  
flip-flops, and control circuitry arranged for  
multiplexed transmission of data directly from the  
data bus or from the internal storage registers.  
Data on the A or B bus is clocked into the registers  
on the low-to-high transition of the appropriate  
clock (CLKAB or CLKBA) input. Figure 1  
illustrates the four fundamental bus-management  
functions that can be performed with the octal bus  
transceivers and registers.  
SN54ALS646, SN54ALS648, SN54AS646 . . . FK PACKAGE  
(TOP VIEW)  
4
3
2
1
28 27 26  
25  
OE  
B1  
B2  
NC  
A1  
A2  
A3  
NC  
A4  
A5  
A6  
5
24  
23  
22  
6
7
8
21 B3  
20 B4  
9
Output-enable (OE) and direction-control (DIR)  
inputs control the transceiver functions. In the  
transceiver mode, data present at the high-  
impedance port may be stored in either or both  
registers.  
10  
11  
19  
B5  
12 13 14 15 16 17 18  
The select-control (SAB and SBA) inputs can  
multiplex stored and real-time (transparent mode)  
NC – No internal connection  
data. Thecircuitryusedforselectcontroleliminatesthetypicaldecodingglitchthatoccursinamultiplexerduring  
the transition between stored and real-time data. DIR determines which bus receives data when OE is low. In  
the isolation mode (OE high), A data may be stored in one register and/or B data may be stored in the other  
register.  
When an output function is disabled, the input function is still enabled and can be used to store and transmit  
data. Only one of the two buses, A or B, may be driven at a time.  
The -1 version of the SN74ALS646A is identical to the standard version, except that the recommended  
maximum I  
SN54ALS648, or SN74ALS648A.  
in the -1 version is increased to 48 mA. There are no -1 versions of the SN54ALS646,  
OL  
The SN54ALS646, SN54ALS648, and SN54AS646 are characterized for operation over the full military  
temperature range of 55°C to 125°C. The SN74ALS646A, SN74ALS648A, SN74AS646, and SN74AS648 are  
characterized for operation from 0°C to 70°C.  
Copyright 1995, Texas Instruments Incorporated  
PRODUCTION DATA information is current as of publication date.  
Products conform to specifications per the terms of Texas Instruments  
standard warranty. Production processing does not necessarily include  
testing of all parameters.  
1
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ALS646, SN54ALS648, SN54AS646  
SN74ALS646A, SN74ALS648A, SN74AS646, SN74AS648  
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS  
SDAS039F – DECEMBER 1983 – REVISED JANUARY 1995  
21  
3
1
23  
2
22  
SBA  
L
21  
3
DIR  
H
1
23  
CLKAB CLKBA SAB  
L
2
22  
SBA  
X
DIR CLKAB CLKBA SAB  
L
OE  
L
OE  
L
X
X
X
X
X
REAL-TIME TRANSFER  
BUS B TO BUS A  
REAL-TIME TRANSFER  
BUS A TO BUS B  
21  
3
1
23  
2
22  
21  
OE  
L
3
DIR  
L
1
23  
2
22  
SBA  
H
DIR CLKAB CLKBA SAB  
SBA  
X
CLKAB CLKBA SAB  
OE  
X
X
X
X
X
X
X
X
X
X
H or L  
X
X
H
X
H
X
X
L
H
H or L  
X
STORAGE FROM  
A, B, OR A AND B  
TRANSFER STORED DATA  
TO A AND/OR B  
Figure 1. Bus-Management Functions  
Pin numbers shown are for the DW, JT, and NT packages.  
2
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ALS646, SN54ALS648, SN54AS646  
SN74ALS646A, SN74ALS648A, SN74AS646, SN74AS648  
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS  
SDAS039F – DECEMBER 1983 – REVISED JANUARY 1995  
Function Tables  
SN54ALS646, SN54AS646, SN74ALS646A, SN74AS646  
INPUTS  
DATA I/O  
OPERATION OR FUNCTION  
DIR  
X
CLKAB  
CLKBA  
SAB  
X
SBA  
X
A1A8  
Input  
B1B8  
OE  
X
X
H
H
L
X
Unspecified  
Store A, B unspecified  
Store B, A unspecified  
Store A and B data  
X
X
X
X
Unspecified  
Input  
X
H or L  
X
H or L  
X
X
X
Input  
Input  
X
X
X
Input disabled  
Output  
Input disabled  
Input  
Isolation, hold storage  
Real-time B data to A bus  
Stored B data to A bus  
Real-time A data to B bus  
Stored A data to B bus  
L
X
L
L
L
X
H or L  
X
X
H
Output  
Input  
L
H
H
X
L
X
Input  
Output  
L
H or L  
X
H
X
Input  
Output  
The data output functions can be enabled or disabled by various signals at OE and DIR. Data input functions are always enabled; i.e., data at  
the bus terminals is stored on every low-to-high transition of the clock inputs.  
SN54ALS648, SN74ALS648A, SN74AS648  
INPUTS  
DATA I/O  
OPERATION OR FUNCTION  
DIR  
X
CLKAB  
CLKBA  
SAB  
X
SBA  
X
A1A8  
Input  
B1B8  
OE  
X
X
H
H
L
X
Unspecified  
Store A, B unspecified  
Store B, A unspecified  
Store A and B data  
X
X
X
X
Unspecified  
Input  
Input  
X
H or L  
X
H or L  
X
X
X
Input  
X
X
X
Input disabled  
Output  
Input disabled  
Input  
Isolation, hold storage  
Real-time B data to A bus  
Stored B data to A bus  
Real-time A data to B bus  
Stored A data to B bus  
L
X
L
L
L
X
H or L  
X
X
H
Output  
Input  
L
H
H
X
L
X
Input  
Output  
L
H or L  
X
H
X
Input  
Output  
The data output functions can be enabled or disabled by various signals at OE and DIR. Data input functions are always enabled; i.e., data at  
the bus terminals is stored on every low-to-high transition of the clock inputs.  
3
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ALS646, SN54ALS648, SN54AS646  
SN74ALS646A, SN74ALS648A, SN74AS646, SN74AS648  
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS  
SDAS039F – DECEMBER 1983 – REVISED JANUARY 1995  
logic symbols  
SN54ALS648,  
SN74ALS648A, SN74AS648  
SN54ALS646, SN54AS646,  
SN74ALS646A, SN74AS646  
21  
3
21  
3
OE  
OE  
G3  
G3  
DIR  
3 EN1 [BA]  
3 EN2 [AB]  
DIR  
3 EN1 [BA]  
3 EN2 [AB]  
23  
22  
1
23  
22  
1
CLKBA  
SBA  
CLKBA  
SBA  
C4  
G5  
C4  
G5  
CLKAB  
SAB  
CLKAB  
SAB  
C6  
G7  
C6  
G7  
2
2
20  
20  
4D  
2
B1  
4D  
2
B1  
5
5
1  
1  
4
4
A1  
A1  
1
1
5 1  
1  
5 1  
1  
6D  
7
7
6D  
7
7
1
1
5
19  
18  
17  
16  
15  
14  
13  
5
19  
18  
17  
16  
15  
14  
13  
A2  
A3  
A4  
A5  
A6  
A7  
A8  
B2  
B3  
B4  
B5  
B6  
B7  
B8  
A2  
A3  
A4  
A5  
A6  
A7  
A8  
B2  
B3  
B4  
B5  
B6  
B7  
B8  
6
6
7
7
8
8
9
9
10  
11  
10  
11  
These symbols are in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.  
Pin numbers shown are for the DW, JT, and NT packages.  
4
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ALS646, SN54ALS648, SN54AS646  
SN74ALS646A, SN74ALS648A, SN74AS646, SN74AS648  
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS  
SDAS039F – DECEMBER 1983 – REVISED JANUARY 1995  
logic diagrams (positive logic)  
SN54ALS646, SN54AS646,  
SN74ALS646A, SN74AS646  
21  
OE  
3
DIR  
CLKBA  
SBA  
23  
22  
1
CLKAB  
2
SAB  
One of Eight Channels  
1D  
C1  
4
A1  
20  
B1  
1D  
C1  
To Seven Other Channels  
SN54ALS648,  
SN74ALS648A, SN74AS648  
21  
OE  
3
DIR  
CLKBA  
SBA  
23  
22  
1
CLKAB  
2
SAB  
One of Eight Channels  
1D  
C1  
4
A1  
20  
B1  
1D  
C1  
To Seven Other Channels  
Pin numbers shown are for the DW, JT, and NT packages.  
5
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ALS646, SN54ALS648, SN54AS646  
SN74ALS646A, SN74ALS648A, SN74AS646, SN74AS648  
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS  
SDAS039F – DECEMBER 1983 – REVISED JANUARY 1995  
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)  
Supply voltage, V  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V  
CC  
Input voltage, V : Control inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V  
I
I/O ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 V  
Operating free-air temperature range, T : SN54ALS646 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55°C to 125°C  
A
SN74ALS646A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C  
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65°C to 150°C  
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and  
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not  
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.  
recommended operating conditions  
SN54ALS646  
MIN NOM MAX  
SN74ALS646A  
MIN NOM MAX  
UNIT  
V
V
V
Supply voltage  
4.5  
2
5
5.5  
4.5  
2
5
5.5  
V
V
CC  
High-level input voltage  
Low-level input voltage  
High-level output current  
IH  
0.7  
12  
12  
0.8  
15  
24  
V
IL  
I
mA  
OH  
I
Low-level output current  
mA  
OL  
48  
f
t
t
t
Clock frequency  
0
14.5  
15  
35  
0
12.5  
10  
0
40  
MHz  
ns  
clock  
Pulse duration, CLKBA or CLKAB high or low  
Setup time, A before CLKABor B before CLKBA↑  
Hold time, A after CLKABor B after CLKBA↑  
Operating free-air temperature  
w
ns  
su  
h
0
ns  
T
55  
125  
0
70  
°C  
A
Applies only to the -1 version and only if V  
CC  
is maintained between 4.75 V and 5.25  
6
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ALS646, SN54ALS648, SN54AS646  
SN74ALS646A, SN74ALS648A, SN74AS646, SN74AS648  
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS  
SDAS039F – DECEMBER 1983 – REVISED JANUARY 1995  
electrical characteristics over recommended operating free-air temperature range (unless  
otherwise noted)  
SN54ALS646  
SN74ALS646A  
PARAMETER  
TEST CONDITIONS  
UNIT  
MIN TYP  
MAX  
MIN TYP  
MAX  
V
V
V
V
= 4.5 V,  
I = 18 mA  
1.2  
1.2  
V
IK  
CC  
I
= 4.5 V to 5.5 V,  
I
I
I
I
I
I
I
= 0.4 mA  
= 3 mA  
= 12 mA  
= 15 mA  
= 12 mA  
V
–2  
V
–2  
CC  
OH  
OH  
OH  
OH  
OL  
OL  
OL  
CC  
2.4  
CC  
2.4  
3.2  
3.2  
V
V
OH  
V
V
= 4.5 V  
= 4.5 V  
2
CC  
2
0.25  
0.4  
0.25  
0.35  
0.35  
0.4  
0.5  
0.5  
0.1  
0.1  
20  
V
OL  
= 24 mA  
CC  
= 48 mA  
Control inputs  
A or B ports  
V = 7 V  
I
0.1  
0.1  
I
I
V
V
= 5.5 V  
= 5.5 V,  
mA  
I
CC  
V = 5.5 V  
I
Control inputs  
20  
V = 2.7 V  
I
µA  
IH  
IL  
CC  
§
20  
20  
A or B ports  
Control inputs  
0.2  
0.2  
112  
76  
0.2  
0.2  
112  
76  
I
I
V
V
= 5.5 V,  
= 5.5 V,  
V = 0.4 V  
I
mA  
mA  
CC  
§
A or B ports  
V
O
= 2.25 V  
20  
30  
CC  
O
Outputs high  
Outputs low  
47  
55  
55  
47  
55  
55  
I
V
CC  
= 5.5 V  
88  
88  
mA  
CC  
Outputs disabled  
88  
88  
All typical values are at V  
Applies only to the -1 version and only if V  
CC  
For I/O ports, the parameters I and I include the off-state output current.  
= 5 V, T = 25°C.  
A
CC  
§
is maintained between 4.75 V and 5.25  
IH  
IL  
The output conditions have been chosen to produce a current that closely approximates one half of the true short-circuit output current, I  
.
OS  
7
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ALS646, SN54ALS648, SN54AS646  
SN74ALS646A, SN74ALS648A, SN74AS646, SN74AS648  
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS  
SDAS039F – DECEMBER 1983 – REVISED JANUARY 1995  
switching characteristics (see Figure 2)  
V
C
= 4.5 V to 5.5 V,  
= 50 pF,  
CC  
L
R1 = 500 ,  
R2 = 500 ,  
T
A
FROM  
(INPUT)  
TO  
(OUTPUT)  
PARAMETER  
UNIT  
= MIN to MAX  
SN54ALS646 SN74ALS646A  
MIN  
35  
10  
5
MAX  
MIN  
40  
7
MAX  
f
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
MHz  
ns  
max  
PLH  
PHL  
PLH  
PHL  
PLH  
PHL  
PLH  
PHL  
PZH  
PZL  
PHZ  
PLZ  
PZH  
PZL  
PHZ  
PLZ  
35  
20  
22  
15  
40  
23  
30  
24  
20  
22  
12  
20  
38  
30  
12  
21  
30  
17  
20  
12  
35  
20  
25  
20  
17  
20  
10  
16  
30  
25  
10  
16  
CLKBA or CLKAB  
A or B  
A or B  
B or A  
A or B  
A or B  
A or B  
A or B  
A or B  
A or B  
5
5
3
ns  
ns  
ns  
ns  
ns  
ns  
ns  
3
3
10  
5
7
SBA or SAB  
(stored data low)  
5
8
6
SBA or SAB  
(stored data high)  
5
5
3
2
OE  
5
4
1
1
OE  
1
2
5
3
DIR  
5
4
1
1
DIR  
2
2
For conditions shown MIN or MAX, use the appropriate value specified under recommended operating conditions.  
These parameters are measured with the internal output state of the storage register opposite that of the bus input.  
8
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ALS646, SN54ALS648, SN54AS646  
SN74ALS646A, SN74ALS648A, SN74AS646, SN74AS648  
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS  
SDAS039F – DECEMBER 1983 – REVISED JANUARY 1995  
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)  
Supply voltage, V  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V  
CC  
Input voltage, V : Control inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V  
I
I/O ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 V  
Operating free-air temperature range, T : SN54ALS648 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55°C to 125°C  
A
SN74ALS648A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C  
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65°C to 150°C  
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and  
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not  
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.  
recommended operating conditions  
SN54ALS648  
MIN NOM MAX  
SN74ALS648A  
MIN NOM MAX  
UNIT  
V
V
V
Supply voltage  
4.5  
2
5
5.5  
4.5  
2
5
5.5  
V
V
CC  
High-level input voltage  
IH  
Low-level input voltage  
0.7  
12  
12  
0.8  
15  
24  
V
IL  
I
I
f
t
t
t
High-level output current  
mA  
mA  
MHz  
ns  
OH  
OL  
clock  
w
Low-level output current  
Clock frequency  
0
14.5  
15  
35  
0
12.5  
10  
0
40  
Pulse duration, CLKBA or CLKAB high or low  
Setup time, A before CLKABor B before CLKBA↑  
Hold time, A after CLKABor B after CLKBA↑  
Operating free-air temperature  
ns  
su  
0
ns  
h
T
A
55  
125  
0
70  
°C  
9
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ALS646, SN54ALS648, SN54AS646  
SN74ALS646A, SN74ALS648A, SN74AS646, SN74AS648  
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS  
SDAS039F – DECEMBER 1983 – REVISED JANUARY 1995  
electrical characteristics over recommended operating free-air temperature range (unless  
otherwise noted)  
SN54ALS648  
SN74ALS648A  
PARAMETER  
TEST CONDITIONS  
UNIT  
MIN TYP  
MAX  
MIN TYP  
MAX  
V
V
V
V
= 4.5 V,  
I = 18 mA  
1.2  
1.2  
V
IK  
CC  
I
= 4.5 V to 5.5 V,  
I
I
I
I
I
I
= 0.4 mA  
= 3 mA  
= 12 mA  
= 15 mA  
= 12 mA  
V
–2  
V
–2  
CC  
OH  
OH  
OH  
OH  
OL  
OL  
CC  
2.4  
CC  
2.4  
3.2  
3.2  
V
OH  
V
CC  
= 4.5 V  
2
2
0.25  
0.4  
0.25  
0.35  
0.4  
0.5  
V
OL  
V
CC  
V
CC  
V
CC  
= 4.5 V  
= 5.5 V  
= 5.5 V,  
V
= 24 mA  
Control inputs  
A or B ports  
V = 7 V  
I
0.1  
0.1  
0.1  
I
I
mA  
µA  
V = 5.5 V  
I
0.1  
Control inputs  
20  
20  
I
V = 2.7 V  
I
IH  
IL  
20  
20  
A or B ports  
Control inputs  
0.2  
0.2  
112  
76  
0.2  
0.2  
112  
76  
I
I
V
V
= 5.5 V,  
= 5.5 V,  
V = 0.4 V  
I
mA  
mA  
CC  
A or B ports  
§
V
O
= 2.25 V  
20  
30  
CC  
O
Outputs high  
Outputs low  
47  
57  
57  
47  
57  
57  
I
V
CC  
= 5.5 V  
88  
88  
mA  
CC  
Outputs disabled  
88  
88  
§
All typical values are at V  
For I/O ports, the parameters I and I include the off-state output current.  
The output conditions have been chosen to produce a current that closely approximates one half of the true short-circuit output current, I  
= 5 V, T = 25°C.  
A
IH IL  
CC  
.
OS  
10  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ALS646, SN54ALS648, SN54AS646  
SN74ALS646A, SN74ALS648A, SN74AS646, SN74AS648  
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS  
SDAS039F – DECEMBER 1983 – REVISED JANUARY 1995  
switching characteristics (see Figure 2)  
V
C
= 4.5 V to 5.5 V,  
= 50 pF,  
CC  
L
R1 = 500 ,  
R2 = 500 ,  
T
A
FROM  
TO  
(OUTPUT)  
PARAMETER  
(INPUT)  
UNIT  
= MIN to MAX  
SN54ALS648 SN74ALS648A  
MIN  
35  
8
MAX  
MIN  
40  
7
MAX  
f
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
MHz  
ns  
max  
PLH  
PHL  
PLH  
PHL  
PLH  
PHL  
PLH  
PHL  
PZH  
PZL  
PHZ  
PLZ  
PZH  
PZL  
PHZ  
PLZ  
39  
23  
20  
12  
44  
26  
30  
25  
25  
25  
12  
21  
35  
25  
17  
22  
33  
20  
17  
10  
39  
22  
25  
21  
22  
22  
10  
15  
27  
19  
14  
15  
CLKBA or CLKAB  
A or B  
A or B  
B or A  
A or B  
A or B  
A or B  
A or B  
A or B  
A or B  
5
5
3
2
ns  
ns  
ns  
ns  
ns  
ns  
ns  
2
2
5
5
SBA or SAB  
(stored data low)  
4
4
6
6
SBA or SAB  
(stored data high)  
6
6
4
2
OE  
4
4
1
1
OE  
2
2
4
2
DIR  
3
3
1
1
DIR  
2
2
For conditions shown MIN or MAX, use the appropriate value specified under recommended operating conditions.  
These parameters are measured with the internal output state of the storage register opposite that of the bus input.  
11  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ALS646, SN54ALS648, SN54AS646  
SN74ALS646A, SN74ALS648A, SN74AS646, SN74AS648  
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS  
SDAS039F – DECEMBER 1983 – REVISED JANUARY 1995  
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)  
Supply voltage, V  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V  
CC  
Input voltage, V : Control inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V  
I
I/O ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 V  
Operating free-air temperature range, T : SN54AS646 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55°C to 125°C  
A
SN74AS646 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C  
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65°C to 150°C  
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and  
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not  
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.  
recommended operating conditions  
SN54AS646  
MIN NOM  
SN74AS646  
MIN NOM  
UNIT  
MAX  
MAX  
V
V
V
Supply voltage  
4.5  
2
5
5.5  
4.5  
2
5
5.5  
V
V
CC  
High-level input voltage  
Low-level input voltage  
High-level output current  
Low-level output current  
Clock frequency  
IH  
0.8  
–12  
32  
0.8  
–15  
48  
V
IL  
I
I
f
mA  
mA  
MHz  
OH  
OL  
clock  
*
0
6
75  
0
5
6
6
0
0
90  
CLKBA or CLKAB high  
CLKBA or CLKAB low  
t *  
w
Pulse duration  
ns  
7
t
*
Setup time, A before CLKABor B before CLKBA↑  
Hold time, A after CLKABor B before CLKBA  
Operating free-air temperature  
7
ns  
ns  
°C  
su  
t *  
0
h
T
A
55  
125  
70  
* On products compliant to MIL-STD-883, Class B, this parameter is based on characterization data but is not production tested.  
12  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ALS646, SN54ALS648, SN54AS646  
SN74ALS646A, SN74ALS648A, SN74AS646, SN74AS648  
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS  
SDAS039F – DECEMBER 1983 – REVISED JANUARY 1995  
electrical characteristics over recommended operating free-air temperature range (unless  
otherwise noted)  
SN54AS646  
SN74AS646  
PARAMETER  
TEST CONDITIONS  
UNIT  
MIN TYP  
MAX  
MIN TYP  
MAX  
V
V
V
V
= 4.5 V,  
I = 18 mA  
1.2  
1.2  
V
IK  
CC  
I
= 4.5 V to 5.5 V,  
I
I
I
I
I
I
= 2 mA  
= 3 mA  
= 12 mA  
= 15 mA  
= 32 mA  
= 48 mA  
V
–2  
V
–2  
CC  
OH  
OH  
OH  
OH  
OL  
OL  
CC  
2.4  
CC  
2.4  
3.2  
3.2  
V
OH  
V
CC  
= 4.5 V  
2
2
0.25  
0.5  
V
OL  
V
CC  
= 4.5 V  
V
0.35  
0.5  
0.1  
Control inputs  
A or B ports  
V
V
= 5.5 V,  
= 5.5 V,  
V = 7 V  
I
0.1  
0.1  
CC  
I
I
mA  
µA  
V = 5.5 V  
I
0.1  
CC  
Control inputs  
20  
20  
I
V
CC  
= 5.5 V,  
V = 2.7 V  
I
IH  
IL  
70  
70  
A or B ports  
Control input  
0.5  
0.75  
112  
195  
211  
0.5  
0.75  
112  
195  
211  
I
I
V
V
= 5.5 V,  
= 5.5 V,  
V = 0.4 V  
I
mA  
mA  
CC  
A or B ports  
§
V
O
= 2.25 V  
30  
30  
CC  
O
Outputs high  
Outputs low  
120  
130  
130  
120  
130  
130  
I
V
CC  
= 5.5 V  
mA  
CC  
Outputs disabled  
211  
211  
§
All typical values are at V  
= 5 V, T = 25 °C.  
A
CC  
For I/O ports, the parameters I and I include the off-state output current.  
IH  
IL  
The output conditions have been chosen to produce a current that closely approximates one half of the true short-circuit output current, I  
.
OS  
13  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ALS646, SN54ALS648, SN54AS646  
SN74ALS646A, SN74ALS648A, SN74AS646, SN74AS648  
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS  
SDAS039F – DECEMBER 1983 – REVISED JANUARY 1995  
switching characteristics (see Figure 2)  
V
C
= 4.5 V to 5.5 V,  
= 50 pF,  
CC  
L
R1 = 500 ,  
R2 = 500 ,  
T
A
FROM  
(INPUT)  
TO  
(OUTPUT)  
PARAMETER  
UNIT  
= MIN to MAX  
SN54AS646  
SN74AS646  
MIN  
75  
2
MAX  
MIN  
90  
2
MAX  
f
t
t
t
t
t
t
t
t
t
t
t
t
t
t
*
MHz  
ns  
max  
9.5  
10  
8.5  
9
PLH  
PHL  
PLH  
PHL  
PLH  
PHL  
PZH  
PZL  
PHZ  
PLZ  
PZH  
PZL  
PHZ  
PLZ  
CLKBA or CLKAB  
A or B  
A or B  
B or A  
A or B  
A or B  
A or B  
A or B  
A or B  
2
2
2
11.5  
8
2
9
ns  
ns  
ns  
ns  
ns  
ns  
1
1
7
2
13.5  
11  
2
11  
9
SBA or SAB  
2
2
2
11  
2
9
OE  
OE  
3
15  
3
14  
9
2
11  
2
2
11  
2
9
3
21  
3
16  
18  
10  
10  
DIR  
DIR  
3
24  
3
2
12  
2
2
12  
2
* On products compliant to MIL-STD-883, Class B, this parameter is based on characterization data but is not production tested.  
For conditions shown MIN or MAX, use the appropriate value specified under recommended operating conditions.  
These parameters are measured with the internal output state of the storage register opposite that of the bus input.  
14  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ALS646, SN54ALS648, SN54AS646  
SN74ALS646A, SN74ALS648A, SN74AS646, SN74AS648  
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS  
SDAS039F – DECEMBER 1983 – REVISED JANUARY 1995  
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)  
Supply voltage, V  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V  
CC  
Input voltage, V : Control inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V  
I
I/O ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 V  
Operating free-air temperature range, T : SN74AS648 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C  
A
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65°C to 150°C  
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and  
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not  
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.  
recommended operating conditions  
SN74AS648  
MIN NOM  
UNIT  
MAX  
V
V
V
Supply voltage  
4.5  
2
5
5.5  
V
V
CC  
High-level input voltage  
Low-level input voltage  
High-level output current  
Low-level output current  
Clock frequency  
IH  
0.8  
–15  
48  
V
IL  
I
I
f
mA  
mA  
MHz  
OH  
OL  
clock  
0
5
6
6
0
0
90  
CLKBA or CLKAB high  
CLKBA or CLKAB low  
t
w
Pulse duration  
ns  
t
t
Setup time, A before CLKABor B before CLKBA↑  
Hold time, A after CLKABor B before CLKBA  
Operating free-air temperature  
ns  
ns  
°C  
su  
h
T
A
70  
electrical characteristics over recommended operating free-air temperature range (unless  
otherwise noted)  
SN74AS648  
PARAMETER  
TEST CONDITIONS  
UNIT  
MIN TYP  
MAX  
V
V
V
V
V
= 4.5 V,  
I = 18 mA  
1.2  
V
IK  
CC  
I
= 4.5 V to 5.5 V,  
I
I
I
I
= 2 mA  
= 3 mA  
= 15 mA  
= 48 mA  
V
–2  
CC  
OH  
OH  
OH  
OL  
CC  
2.4  
3.2  
V
OH  
OL  
V
CC  
V
CC  
V
CC  
= 4.5 V  
2
= 4.5 V,  
0.35  
0.5  
0.1  
V
Control inputs  
A or B ports  
V = 7 V  
I
I
I
= 5.5 V  
mA  
V = 5.5 V  
I
0.1  
Control inputs  
20  
I
V
= 5.5 V,  
V = 2.7 V  
µA  
IH  
IL  
CC  
I
§
70  
A or B ports  
Control input  
0.5  
0.75  
112  
185  
195  
195  
I
I
V
V
= 5.5 V,  
= 5.5 V,  
V = 0.4 V  
I
mA  
mA  
CC  
§
A or B ports  
V
O
= 2.25 V  
30  
CC  
O
Outputs high  
Outputs low  
110  
120  
120  
I
V
CC  
= 5.5 V  
mA  
CC  
Outputs disabled  
§
All typical values are at V  
= 5 V, T = 25 °C.  
A
CC  
For I/O ports, the parameters I and I include the off-state output current.  
IH  
IL  
The output conditions have been chosen to produce a current that closely approximates one half of the true short-circuit output current, I  
.
OS  
15  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ALS646, SN54ALS648, SN54AS646  
SN74ALS646A, SN74ALS648A, SN74AS646, SN74AS648  
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS  
SDAS039F – DECEMBER 1983 – REVISED JANUARY 1995  
switching characteristics (see Figure 2)  
V
C
= 4.5 V to 5.5 V,  
= 50 pF,  
CC  
L
R1 = 500 ,  
R2 = 500 ,  
T
A
FROM  
(INPUT)  
TO  
(OUTPUT)  
PARAMETER  
UNIT  
= MIN to MAX  
SN74AS648  
MIN  
90  
2
MAX  
f
t
t
t
t
t
t
t
t
t
t
t
t
t
t
MHz  
ns  
max  
PLH  
PHL  
PLH  
PHL  
PLH  
PHL  
PZH  
PZL  
PHZ  
PLZ  
PZH  
PZL  
PHZ  
PLZ  
8.5  
9
CLKBA or CLKAB  
A or B  
A or B  
B or A  
A or B  
A or B  
A or B  
A or B  
A or B  
2
2
8
ns  
ns  
ns  
ns  
ns  
ns  
1
7
2
11  
9
SBA or SAB  
2
2
9
OE  
OE  
3
15  
9
2
2
9
3
16  
18  
10  
10  
DIR  
DIR  
3
2
2
For conditions shown MIN or MAX, use the appropriate value specified under recommended operating conditions.  
These parameters are measured with the internal output state of the storage register opposite that of the bus input.  
16  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ALS646, SN54ALS648, SN54AS646  
SN74ALS646A, SN74ALS648A, SN74AS646, SN74AS648  
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS  
SDAS039F – DECEMBER 1983 – REVISED JANUARY 1995  
PARAMETER MEASUREMENT INFORMATION  
7 V  
V
CC  
SWITCH POSITION TABLE  
Open  
S1  
TEST  
S1  
R
L
t
t
Open  
Open  
Open  
Closed  
Open  
Closed  
PLH  
PHL  
PZH  
R1 = 500 Ω  
From Output  
Under Test  
Test Point  
From Output  
Under Test  
Test Point  
R2 = 500 Ω  
t
t
PZL  
PHZ  
C = 50 pF  
L
(see Note A)  
C
= 50 pF  
L
t
(see Note A)  
t
PLZ  
LOAD CIRCUIT  
FOR 3-STATE OUTPUTS  
LOAD CIRCUIT  
FOR OPEN-COLLECTOR OUTPUTS  
3.5 V  
3.5 V  
1.3 V  
1.3 V  
High-Level  
Timing  
Input  
1.3 V  
Pulse  
0.3 V  
t
0.3 V  
3.5 V  
w
t
h
t
su  
3.5 V  
0.3 V  
Data  
Input  
Low-Level  
Pulse  
1.3 V  
1.3 V  
1.3 V  
1.3 V  
0.3 V  
VOLTAGE WAVEFORMS  
PULSE DURATION  
VOLTAGE WAVEFORMS  
SETUP AND HOLD TIMES  
3.5 V  
Output  
Control  
1.3 V  
1.3 V  
0.3 V  
3.5 V  
3.5 V  
t
Input  
1.3 V  
1.3 V  
PZL  
t
PLZ  
0.3 V  
PHL  
t
t
PLH  
Waveform 1  
S1 Closed  
(see Note B)  
1.3 V  
V
OH  
In-Phase  
Output  
1.3 V  
1.3 V  
1.3 V  
V
OL  
V
OL  
0.3 V  
t
PHZ  
t
PLH  
t
PZH  
t
PHL  
V
OH  
V
Waveform 2  
S1 Open  
(see Note B)  
OH  
OL  
Out-of-Phase  
Output  
1.3 V  
1.3 V  
0.3 V  
0 V  
V
VOLTAGE WAVEFORMS  
PROPAGATION DELAY TIMES  
VOLTAGE WAVEFORMS  
ENABLE AND DISABLE TIMES, 3-STATE OUTPUTS  
NOTES: A.  
C
L
includes probe and jig capacitance.  
B. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control.  
Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control.  
C. All input pulses are supplied by generators having the following characteristics: PRR 1 MHz, Z = 50 , t 2 ns, t 2 ns.  
O
r
f
D. The outputs are measured one at a time with one transition per measurement.  
Figure 2. Load Circuits and Voltage Waveforms  
17  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
IMPORTANT NOTICE  
Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue  
any product or service without notice, and advise customers to obtain the latest version of relevant information  
to verify, before placing orders, that information being relied on is current and complete. All products are sold  
subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those  
pertaining to warranty, patent infringement, and limitation of liability.  
TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in  
accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent  
TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily  
performed, except those mandated by government requirements.  
CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF  
DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL  
APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR  
WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER  
CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO  
BE FULLY AT THE CUSTOMER’S RISK.  
In order to minimize risks associated with the customer’s applications, adequate design and operating  
safeguards must be provided by the customer to minimize inherent or procedural hazards.  
TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent  
that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other  
intellectual property right of TI covering or relating to any combination, machine, or process in which such  
semiconductor products or services might be or are used. TI’s publication of information regarding any third  
party’s products or services does not constitute TI’s approval, warranty or endorsement thereof.  
Copyright 1998, Texas Instruments Incorporated  

相关型号:

5962-8995601LX

Single 8-bit Bus Transceiver
ETC

5962-89957012A

Switched Mode Controller for DC Motor Drive
TI

5962-89957012X

Servo Motor Controller/Driver
ETC

5962-8995701VA

Switched Mode Controller for DC Motor Drive
TI

5962-8995701VSA

RAD-TOLERANT CLASS-V, SWITCHED MODE CONTROLLER FOR DC MOTOR DRIVE
TI

5962-8995701VX

Servo Motor Controller/Driver
ETC

5962-8995901XX

Fixed Point ALU
ETC

5962-8995901YA

Bit-Slice Processor, 16-Bit, CMOS, CQCC68
LOGIC

5962-8995901YX

Fixed Point ALU
ETC

5962-8995901ZC

IC 16-BIT, BIT-SLICE MICROPROCESSOR, CPGA68, Bit-Slice Processor
WEDC

5962-8995901ZX

Fixed Point ALU
ETC

5962-8995902YX

Fixed Point ALU
ETC