74AC11151 [TI]

1-OF-8 DATA SELECTOR/MULTIPLEXER; 1 - OF- 8数据选择器/多路复用器
74AC11151
型号: 74AC11151
厂家: TEXAS INSTRUMENTS    TEXAS INSTRUMENTS
描述:

1-OF-8 DATA SELECTOR/MULTIPLEXER
1 - OF- 8数据选择器/多路复用器

复用器
文件: 总7页 (文件大小:89K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
74AC11151  
1-OF-8 DATA SELECTOR/MULTIPLEXER  
SCAS066A – JUNE 1989 – REVISED APRIL 1993  
D OR N PACKAGE  
(TOP VIEW)  
8-Line to 1-Line Multiplexers Can Perform  
as Boolean Function Generators,  
Parallel-to-Serial Converters, or Data  
Source Selectors  
D1  
D2  
D3  
D4  
V
D0  
OE  
Y
GND  
W
1
2
3
4
5
6
7
8
16  
15  
14  
13  
12  
11  
10  
9
Flow-Through Architecture Optimizes  
PCB Layout  
Center-Pin V  
and GND Configurations  
Minimize High-Speed Switching Noise  
CC  
CC  
D5  
D6  
D7  
A
B
C
EPIC (Enhanced-Performance Implanted  
CMOS) 1-µm Process  
500-mA Typical Latch-Up Immunity  
at 125°C  
Package Options Include Plastic  
Small-Outline Packages and Standard  
Plastic 300-mil DIPs  
description  
This monolithic data selector/multiplexer provides full binary decoding to select one-of-eight data sources. The  
strobe output-enable (OE) input must be at a low logic level to enable the inputs. A high level at the strobe  
terminal forces the W output high and the Y output low.  
The 74AC11151 is characterized for operation from 40°C to 85°C.  
FUNCTION TABLE  
INPUTS  
logic symbol  
OUTPUTS  
MUX  
2
SELECT  
STROBE  
OE  
EN  
0
Y
W
OE  
C
X
L
B
X
L
A
X
L
6
A
7
H
L
L
L
L
L
L
L
L
L
H
0
G
B
8
D0  
D1  
D2  
D3  
D4  
D5  
D6  
D7  
D0  
D1  
D2  
D3  
D4  
D5  
D6  
D7  
7
C
1
2
0
1
2
3
4
5
6
7
L
L
H
L
3
5
Y
D0  
L
H
H
L
16  
D1  
W
L
H
L
15  
D2  
H
H
H
H
14  
L
H
L
D3  
13  
H
H
D4  
11  
H
D5  
10  
D6  
9
H = high level, L= low level, X = irrelevant  
D0, D1, . . . D7 = the level of the respective D input  
D7  
This symbol is in accordance with ANSI/IEEE Std 91-1984  
and IEC Publication 617-12.  
EPIC is a trademark of Texas Instruments Incorporated.  
Copyright 1993, Texas Instruments Incorporated  
PRODUCTION DATA information is current as of publication date.  
Products conform to specifications per the terms of Texas Instruments  
standard warranty. Production processing does not necessarily include  
testing of all parameters.  
2–1  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
74AC11151  
1-OF-8 DATA SELECTOR/MULTIPLEXER  
SCAS066A – JUNE 1989 – REVISED APRIL 1993  
logic diagram (positive logic)  
2
OE  
1
D0  
16  
D1  
15  
D2  
14  
D3  
3
5
Data  
Inputs  
Y
13  
D4  
W
11  
D5  
10  
D6  
9
D7  
6
A
Data  
7
B
C
Select  
(Binary)  
8
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)  
Supply voltage range, V  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 V to 7 V  
CC  
Input voltage range, V (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 V to V  
+ 0.5 V  
+ 0.5 V  
I
CC  
CC  
Output voltage range, V (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 V to V  
O
Input clamp current, I (V < 0 or V > V ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20 mA  
IK  
I
I
CC  
Output clamp current, I  
(V < 0 or V > V ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA  
OK  
O O CC  
Continuous output current, I (V = 0 to V ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA  
Continuous current through V  
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65°C to 150°C  
O
O
CC  
CC  
or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±100 mA  
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only and  
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not  
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.  
NOTE 1: The input and output voltage ratings may be exceeded if the input and output clamp-current ratings are observed.  
2–2  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
74AC11151  
1-OF-8 DATA SELECTOR/MULTIPLEXER  
SCAS066A – JUNE 1989 – REVISED APRIL 1993  
recommended operating conditions  
MIN NOM  
MAX  
UNIT  
V
Supply voltage  
3
2.1  
5
5.5  
V
CC  
IH  
V
CC  
V
CC  
V
CC  
V
CC  
V
CC  
V
CC  
= 3 V  
V
High-level input voltage  
= 4.5 V  
= 5.5 V  
= 3 V  
3.15  
3.85  
V
V
0.9  
1.35  
1.65  
V
IL  
Low-level input voltage  
= 4.5 V  
= 5.5 V  
V
V
Input voltage  
0
0
V
V
V
I
CC  
Output voltage  
V
CC  
–4  
O
V
CC  
V
CC  
V
CC  
V
CC  
V
CC  
V
CC  
= 3 V  
I
High-level output current  
Low-level output current  
= 4.5 V  
= 5.5 V  
= 3 V  
24  
24  
12  
mA  
mA  
OH  
OL  
I
= 4.5 V  
= 5.5 V  
24  
24  
t/v  
Input transition rise or fall rate  
Operating free-air temperature  
0
10  
ns/V  
T
A
40  
85  
°C  
electrical characteristics over recommended operating free-air temperature range (unless  
otherwise noted)  
T
A
= 25°C  
PARAMETER  
TEST CONDITIONS  
V
MIN  
MAX  
UNIT  
CC  
MIN  
2.9  
TYP  
MAX  
3 V  
4.5 V  
5.5 V  
3 V  
2.9  
4.4  
I
I
= – 50 µA  
4.4  
OH  
5.4  
5.4  
V
OH  
= – 4 mA  
2.58  
3.94  
4.94  
2.48  
3.8  
V
OH  
4.5 V  
5.5 V  
5.5 V  
3 V  
I
I
= – 24 mA  
OH  
4.8  
= 75 mA  
3.85  
OH  
0.1  
0.1  
0.1  
0.1  
I
= 50 µA  
4.5 V  
5.5 V  
3 V  
OL  
0.1  
0.1  
V
OL  
I
I
I
= 12 mA  
= 24 mA  
0.36  
0.36  
0.36  
0.44  
0.44  
0.44  
1.65  
±1  
V
OL  
OL  
OL  
4.5 V  
5.5 V  
5.5 V  
5.5 V  
5.5 V  
5 V  
= 75 mA  
I
I
V = V  
or GND  
or GND,  
or GND  
±0.1  
µA  
µA  
pF  
I
I
CC  
CC  
CC  
V = V  
I = 0  
O
8
80  
CC  
I
C
V = V  
3.5  
i
I
Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms.  
2–3  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
74AC11151  
1-OF-8 DATA SELECTOR/MULTIPLEXER  
SCAS066A – JUNE 1989 – REVISED APRIL 1993  
switching characteristics over recommended operating free-air temperature range,  
V
= 3.3 V ± 0.3 V (unless otherwise noted) (see Figure 1)  
CC  
FROM  
(INPUT)  
TO  
(OUTPUT)  
PARAMETER  
T
A
= 25°C  
MIN  
MAX  
UNIT  
t
t
t
t
t
t
t
t
t
t
t
t
3.2  
3.4  
3.2  
3.1  
1.9  
1.9  
1.7  
1.9  
1.3  
1.6  
2
8.9  
8.9  
8.6  
8.7  
6.5  
6.4  
6.1  
6.4  
4
10.7  
10.8  
10.3  
10.7  
8.1  
8.1  
7.7  
8
3.2  
3.4  
3.2  
3.1  
1.9  
1.9  
1.7  
1.9  
1.3  
1.6  
2
12  
12.1  
11.6  
12  
PLH  
PHL  
PLH  
PHL  
PLH  
PHL  
PLH  
PHL  
PLH  
PHL  
PLH  
PHL  
A, B, or C  
A, B, or C  
Any D  
Y
W
Y
ns  
ns  
ns  
ns  
ns  
ns  
9.2  
8.9  
8.6  
8.8  
6
Any D  
W
Y
5.5  
5.9  
6.7  
6.2  
OE  
OE  
4.5  
5.2  
4.7  
6.5  
7.4  
6.7  
W
1.7  
1.7  
switching characteristics over recommended operating free-air temperature range,  
= 5 V ± 0.5 V (unless otherwise noted) (see Figure 1)  
V
CC  
T
A
= 25°C  
TYP  
5.4  
5.6  
5.3  
5.4  
4.1  
4
FROM  
(INPUT)  
TO  
(OUTPUT)  
PARAMETER  
MIN  
MAX  
UNIT  
ns  
MIN  
2.5  
2.7  
2.6  
2.6  
1.5  
1.5  
1.4  
1.6  
1.1  
1.4  
1.7  
1.4  
MAX  
7.3  
7.5  
7.2  
7.4  
5.8  
5.7  
5.5  
5.8  
4.2  
4.6  
5.1  
4.6  
t
t
t
t
t
t
t
t
t
t
t
t
2.5  
2.7  
2.6  
2.6  
1.5  
1.5  
1.4  
1.6  
1.1  
1.4  
1.7  
1.4  
8.3  
8.5  
8.1  
8.4  
6.5  
6.4  
6
PLH  
PHL  
PLH  
PHL  
PLH  
PHL  
PLH  
PHL  
PLH  
PHL  
PLH  
PHL  
A, B, or C  
A, B, or C  
Any D  
Y
W
Y
ns  
ns  
3.7  
4.1  
2.7  
3.1  
3.5  
3.1  
Any D  
W
Y
ns  
6.4  
4.6  
5
ns  
OE  
OE  
5.6  
5
W
ns  
operating characteristics, V  
= 5 V, T = 25°C  
A
CC  
PARAMETER  
Power dissipation capacitance  
TEST CONDITIONS  
= 50 pF, f = 1 MHz  
L
TYP  
52  
UNIT  
C
C
pF  
pd  
2–4  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
74AC11151  
1-OF-8 DATA SELECTOR/MULTIPLEXER  
SCAS066A – JUNE 1989 – REVISED APRIL 1993  
PARAMETER MEASUREMENT INFORMATION  
V
CC  
Input  
(see Note B)  
50%  
50%  
0 V  
t
t
From Output  
Under Test  
PHL  
PLH  
PHL  
V
OH  
In-Phase  
Output  
50% V  
50% V  
50% V  
CC  
V
CC  
C
= 50 pF  
L
OL  
500 Ω  
(see Note A)  
t
PLH  
t
V
OH  
Out-of-Phase  
Output  
50% V  
CC  
CC  
V
OL  
VOLTAGE WAVEFORMS  
LOAD CIRCUIT  
NOTES: A.  
C includes probe and jig capacitance.  
L
B. Input pulses are supplied by generators having the following characteristics: PRR 10 MHz, Z = 50 , t = 3 ns, t = 3 ns.  
O
r
f
C. The outputs are measured one at a time with one input transition per measurement.  
Figure 1. Load Circuit and Voltage Waveforms  
2–5  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
2–6  
IMPORTANT NOTICE  
Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue  
any product or service without notice, and advise customers to obtain the latest version of relevant information  
to verify, before placing orders, that information being relied on is current and complete. All products are sold  
subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those  
pertaining to warranty, patent infringement, and limitation of liability.  
TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in  
accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent  
TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily  
performed, except those mandated by government requirements.  
CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF  
DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL  
APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR  
WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER  
CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO  
BE FULLY AT THE CUSTOMER’S RISK.  
In order to minimize risks associated with the customer’s applications, adequate design and operating  
safeguards must be provided by the customer to minimize inherent or procedural hazards.  
TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent  
that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other  
intellectual property right of TI covering or relating to any combination, machine, or process in which such  
semiconductor products or services might be or are used. TI’s publication of information regarding any third  
party’s products or services does not constitute TI’s approval, warranty or endorsement thereof.  
Copyright 1998, Texas Instruments Incorporated  

相关型号:

74AC11151D

Multiplexer, 1-Func, 8 Line Input, CMOS, PDSO16
PHILIPS

74AC11151D

1-OF-8 DATA SELECTOR/MULTIPLEXER
TI

74AC11151D-T

Multiplexer, 1-Func, 8 Line Input, CMOS, PDSO16
PHILIPS

74AC11151D-T

Multiplexer, AC Series, 1-Func, 8 Line Input, 1 Line Output, Complementary Output, CMOS, PDSO16
YAGEO

74AC11151DR

暂无描述
TI

74AC11151J

IC,LOGIC MUX,SINGLE,8-INPUT,AC-CMOS,DIP,16PIN,CERAMIC
TI

74AC11151N

Multiplexer, AC Series, 1-Func, 8 Line Input, 1 Line Output, Complementary Output, CMOS, PDIP16, PLASTIC, DIP-16
ROCHESTER

74AC11151N

1-Of-8 Data Selectors/Multiplexers 16-PDIP -40 to 85
TI

74AC11151N

Multiplexer, AC Series, 1-Func, 8 Line Input, 1 Line Output, Complementary Output, CMOS, PDIP16
YAGEO

74AC11151_09

1-OF-8 DATA SELECTOR/MULTIPLEXER
TI

74AC11153

DUAL 4 INPUT MULTIPLEXER
NXP

74AC11153

DUAL 1-OF-4 DATA SELECTOR/MULTIPLEXER
TI