74AC11253D [TI]

DUAL 1-OF-4 DATA SELECTORS/MULTIPLEXERS WITH 3-STATE OUTPUTS;
74AC11253D
型号: 74AC11253D
厂家: TEXAS INSTRUMENTS    TEXAS INSTRUMENTS
描述:

DUAL 1-OF-4 DATA SELECTORS/MULTIPLEXERS WITH 3-STATE OUTPUTS

输出元件
文件: 总7页 (文件大小:97K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
54AC11253, 74AC11253  
DUAL 1-OF-4 DATA SELECTORS/MULTIPLEXERS  
WITH 3-STATE OUTPUTS  
SCAS041A – MAY 1988 – REVISED APRIL 1993  
54AC11253 . . . J PACKAGE  
74AC11253 . . . D OR N PACKAGE  
(TOP VIEW)  
Permits Multiplexing From N Lines to  
One Line  
Performs Parallel-to-Serial Conversion  
Flow-Through Architecture Optimizes  
1
2
3
4
5
6
7
8
16  
15  
14  
13  
12  
11  
10  
9
1C0  
1C1  
1C2  
1C3  
A
B
1Y  
GND  
2Y  
1G  
PCB Layout  
Center-Pin V  
and GND Configurations  
Minimize High-Speed Switching Noise  
CC  
EPIC (Enhanced-Performance Implanted  
V
CC  
CMOS) 1- m Process  
2C0  
2C1  
2C2  
2G  
2C3  
Package Options Include Plastic Small-  
Outline Packages, Ceramic Chip Carriers,  
and Standard Plastic and Ceramic 300-mil  
DIPs  
54AC11253 . . . FK PACKAGE  
(TOP VIEW)  
description  
Each of these data selectors/multiplexers  
contains inverters and drivers to supply full binary  
decoding data selection to the AND-OR gates.  
Separate output control inputs are provided for  
each of the two four-line sections.  
3
2
1
20 19  
18  
2C1  
2C2  
NC  
1C1  
1C0  
NC  
A
4
5
6
7
8
17  
16  
15  
14  
2C3  
2G  
The three-state outputs can interface with and  
drive data lines of bus-organized systems. With  
all but one of the common outputs disabled (at a  
high-impedance state), the low-impedance of the  
single enabled output will drive the bus line to a  
high or low logic level. Each output has its own  
strobe (G). The output is disabled when its strobe  
is high.  
B
9 10 11 12 13  
NC – No internal connection  
logic symbol  
The 54AC11253 is characterized for operation  
over the full military temperature range of – 55°C  
to 125°C. The 74AC11253 is characterized for  
operation from – 40°C to 85°C.  
1
2
0
1
0
3
A
B
G
MUX  
6
1G  
1C0  
1C1  
1C2  
1C3  
2G  
EN  
0
FUNCTION TABLE  
16  
15  
14  
13  
7
SELECT  
INPUTS  
OUTPUT  
CONTROL  
G
DATA INPUTS  
OUTPUT  
Y
3
5
1
2
3
1Y  
2Y  
B
X
L
A
X
L
C0 C1 C2 C3  
X
L
X
X
X
L
X
X
X
X
X
L
X
X
X
X
X
X
X
L
H
L
L
L
L
L
L
L
L
Z
L
11  
10  
9
L
L
H
X
X
X
X
X
X
H
L
2C0  
2C1  
2C2  
2C3  
L
H
H
L
L
H
X
X
X
X
H
L
H
H
H
H
8
L
H
X
X
H
L
H
H
This symbol is in accordance with ANSI/IEEE Std 91-1984  
and IEC Publication 617-12.  
Pin numbers shown are for the D, J, and N packages.  
H
H
Address inputs A and B are common to both sections.  
EPIC is a trademark of Texas Instruments Incorporated.  
Copyright 1993, Texas Instruments Incorporated  
PRODUCTION DATA information is current as of publication date.  
Products conform to specifications per the terms of Texas Instruments  
standard warranty. Production processing does not necessarily include  
testing of all parameters.  
2–1  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
54AC11253, 74AC11253  
DUAL 1-OF-4 DATA SELECTORS/MULTIPLEXERS  
WITH 3-STATE OUTPUTS  
SCAS041A – MAY 1988 – REVISED APRIL 1993  
logic diagram (positive logic)  
6
1G  
16  
1C0  
15  
1C1  
3
1Y  
Data 1  
14  
1C2  
13  
1C3  
2
B
Select  
1
A
11  
2C0  
10  
2C1  
Data 2  
5
2Y  
9
2C2  
8
2C3  
7
2G  
Pin numbers shown are for the D, J, and N packages.  
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)  
Supply voltage range, V  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 V to 7 V  
CC  
Input voltage range, V (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 V to V  
+ 0.5 V  
+ 0.5 V  
I
CC  
CC  
Output voltage range, V (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 V to V  
O
Input clamp current, I (V < 0 or V > V ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20 mA  
IK  
I
I
CC  
Output clamp current, I  
(V < 0 or V > V ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA  
OK  
O O CC  
Continuous output current, I (V = 0 to V ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 50 mA  
Continuous current through V  
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65°C to 150°C  
O
O
CC  
CC  
or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±100 mA  
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only and  
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not  
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.  
NOTE 1: The input and output voltage ratings may be exceeded provided the input and output current ratings are observed.  
2–2  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
54AC11253, 74AC11253  
DUAL 1-OF-4 DATA SELECTORS/MULTIPLEXERS  
WITH 3-STATE OUTPUTS  
SCAS041A – MAY 1988 – REVISED APRIL 1993  
recommended operating conditions  
54AC11253  
MIN NOM  
74AC11253  
MIN NOM  
UNIT  
MAX  
MAX  
V
V
Supply voltage  
3
2.1  
5
5.5  
3
2.1  
5
5.5  
V
CC  
V
CC  
V
CC  
V
CC  
V
CC  
V
CC  
V
CC  
= 3 V  
High-level input voltage  
= 4.5 V  
= 5.5 V  
= 3 V  
3.15  
3.85  
3.15  
3.85  
V
V
IH  
0.9  
1.35  
1.65  
0.9  
1.35  
1.65  
V
IL  
Low-level input voltage  
= 4.5 V  
= 5.5 V  
V
V
Input voltage  
0
0
V
0
0
V
V
V
I
CC  
CC  
Output voltage  
V
CC  
–4  
V
CC  
–4  
O
V
CC  
V
CC  
V
CC  
V
CC  
V
CC  
V
CC  
= 3 V  
I
High-level output current  
Low-level output current  
= 4.5 V  
= 5.5 V  
= 3 V  
24  
24  
12  
24  
24  
12  
mA  
mA  
OH  
I
= 4.5 V  
= 5.5 V  
24  
24  
OL  
24  
24  
t/ v  
Input transition rise or fall rate  
Operating free-air temperature  
0
10  
0
10  
ns/V  
T
55  
125  
40  
85  
°C  
A
electrical characteristics over recommended operating free-air temperature range (unless  
otherwise noted)  
T
A
= 25°C  
54AC11253  
74AC11253  
PARAMETER  
TEST CONDITIONS  
V
UNIT  
CC  
MIN  
2.9  
TYP  
MAX  
MIN  
2.9  
4.4  
5.4  
2.4  
3.7  
4.7  
3.85  
MAX  
MIN  
2.9  
MAX  
3 V  
4.5 V  
5.5 V  
3 V  
I
= – 50  
A
4.4  
4.4  
OH  
5.4  
5.4  
I
I
= – 4 mA  
2.58  
3.94  
4.94  
2.48  
3.8  
OH  
V
OH  
V
4.5 V  
5.5 V  
5.5 V  
5.5 V  
3 V  
= – 24 mA  
OH  
4.8  
I
I
= – 50 mA  
= – 75 mA  
OH  
3.85  
OH  
0.1  
0.1  
0.1  
0.1  
0.1  
0.1  
I
= 50  
A
4.5 V  
5.5 V  
3 V  
OL  
0.1  
0.1  
0.1  
I
I
= 12 mA  
= 24 mA  
0.36  
0.36  
0.36  
0.5  
0.44  
0.44  
0.44  
OL  
V
OL  
V
4.5 V  
5.5 V  
5.5 V  
5.5 V  
5.5 V  
5.5 V  
5.5 V  
5 V  
0.5  
OL  
0.5  
I
I
= 50 mA  
1.65  
OL  
= 75 mA  
1.65  
± 5  
± 1  
80  
OL  
I
I
I
V
= V or GND  
CC  
± 0.5  
± 0.1  
8
± 10  
± 1  
A
A
OZ  
O
V = V  
or GND  
or GND,  
or GND  
I
I
CC  
CC  
CC  
V = V  
I = 0  
O
160  
A
CC  
I
C
C
V = V  
3.5  
8
pF  
pF  
i
I
V
= V or GND  
CC  
5 V  
o
O
Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms.  
2–3  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
54AC11253, 74AC11253  
DUAL 1-OF-4 DATA SELECTORS/MULTIPLEXERS  
WITH 3-STATE OUTPUTS  
SCAS041A – MAY 1988 – REVISED APRIL 1993  
switching characteristics over recommended operating free-air temperature range,  
V
= 3.3 V ± 0.3 V (unless otherwise noted) (see Figure 1)  
CC  
T
A
= 25°C  
TYP  
7.1  
7.5  
6.8  
7
54AC11253  
74AC11253  
FROM  
(INPUT)  
TO  
(OUTPUT)  
PARAMETER  
UNIT  
ns  
MIN  
1.5  
1.5  
1.5  
1.5  
1.5  
1.5  
1.5  
1.5  
MAX  
9.7  
MIN  
1.5  
1.5  
1.5  
1.5  
1.5  
1.5  
1.5  
1.5  
MAX  
MIN  
1.5  
1.5  
1.5  
1.5  
1.5  
1.5  
1.5  
1.5  
MAX  
t
t
t
t
11.7  
12.1  
9.9  
10.3  
7.2  
8.7  
7
11  
11.4  
9.3  
9.6  
6.8  
8.2  
6.7  
6.9  
PLH  
PHL  
PLH  
PHL  
PZH  
A or B  
Y
Y
Y
Y
10.1  
8.3  
Data (Any C)  
ns  
8.8  
t
4.8  
5.8  
5
6.2  
ns  
G
G
t
7.4  
PZL  
t
6.3  
PHZ  
ns  
t
5.2  
6.5  
7.2  
PLZ  
switching characteristics over recommended operating free-air temperature range,  
= 5 V ± 0.5 V (unless otherwise noted) (see Figure 1)  
V
CC  
T
A
= 25°C  
TYP  
4.9  
54AC11253  
74AC11253  
FROM  
(INPUT)  
TO  
(OUTPUT)  
PARAMETER  
UNIT  
ns  
MIN  
1.5  
1.5  
1.5  
1.5  
1.5  
1.5  
1.5  
1.5  
MAX  
7
MIN  
1.5  
1.5  
1.5  
1.5  
1.5  
1.5  
1.5  
1.5  
MAX  
MIN  
1.5  
1.5  
1.5  
1.5  
1.5  
1.5  
1.5  
1.5  
MAX  
7.9  
8.2  
6.6  
6.9  
5.1  
5.8  
6.3  
6.2  
t
t
t
t
8.3  
8.7  
7.1  
7.3  
6.4  
6.1  
6.6  
6.4  
PLH  
PHL  
PLH  
PHL  
PZH  
A or B  
Y
Y
Y
Y
5.2  
7.3  
5.9  
6.3  
4.6  
5.3  
6
4.5  
Data (Any C)  
ns  
4.8  
t
3.4  
ns  
G
G
t
4
PZL  
PHZ  
t
4.7  
ns  
t
4.6  
5.9  
PLZ  
operating characteristics, V  
= 5 V, T = 25°C  
A
CC  
PARAMETER  
TEST CONDITIONS  
= 50 pF, f = 1 MHz  
L
TYP  
31  
UNIT  
Outputs enabled  
Outputs disabled  
C
Power dissipation capacitance per multiplexer  
C
pF  
pd  
11  
2–4  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
54AC11253, 74AC11253  
DUAL 1-OF-4 DATA SELECTORS/MULTIPLEXERS  
WITH 3-STATE OUTPUTS  
SCAS041A – MAY 1988 – REVISED APRIL 1993  
PARAMETER MEASUREMENT INFORMATION  
2 × V  
CC  
Open  
GND  
TEST  
S1  
S1  
t
/t  
Open  
500 Ω  
PLH PHL  
From Output  
Under Test  
t
/t  
2 × V  
CC  
GND  
PLZ PZL  
t
/t  
PHZ PZH  
C
= 50 pF  
L
500 Ω  
(see Note A)  
LOAD CIRCUIT  
Output  
Control  
(low-level  
enabling)  
V
CC  
50%  
50%  
0 V  
t
PZL  
V
t
CC  
PLZ  
Input  
(see Note B)  
Output  
Waveform 1  
V
CC  
50%  
50%  
50% V  
CC  
0 V  
20% V  
S1 at 2 × V  
(see Note C)  
CC  
CC  
CC  
V
V
OL  
t
PLH  
t
PHZ  
t
PHL  
t
PZH  
Output  
Waveform 2  
S1 at GND  
V
OH  
OH  
0 V  
80% V  
50% V  
50% V  
Output  
CC  
CC  
V
50% V  
CC  
OL  
(see Note C)  
VOLTAGE WAVEFORMS  
NOTES: A. C includes probe and jig capacitance.  
VOLTAGE WAVEFORMS  
L
B. All input pulses are supplied by generators having the following characteristics: PRR 10 MHz, Z = 50 , t = 3 ns, t = 3 ns.  
O
r
f
C. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control.  
Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control.  
D. The outputs are measured one at a time with one input transition per measurement.  
Figure 1. Load Circuit and Voltage Waveforms  
2–5  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
2–6  
IMPORTANT NOTICE  
Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue  
any product or service without notice, and advise customers to obtain the latest version of relevant information  
to verify, before placing orders, that information being relied on is current and complete. All products are sold  
subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those  
pertaining to warranty, patent infringement, and limitation of liability.  
TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in  
accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent  
TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily  
performed, except those mandated by government requirements.  
CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF  
DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL  
APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR  
WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER  
CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO  
BE FULLY AT THE CUSTOMER’S RISK.  
In order to minimize risks associated with the customer’s applications, adequate design and operating  
safeguards must be provided by the customer to minimize inherent or procedural hazards.  
TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent  
that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other  
intellectual property right of TI covering or relating to any combination, machine, or process in which such  
semiconductor products or services might be or are used. TI’s publication of information regarding any third  
party’s products or services does not constitute TI’s approval, warranty or endorsement thereof.  
Copyright 1998, Texas Instruments Incorporated  

相关型号:

74AC11253D-T

Multiplexer, 2-Func, 4 Line Input, CMOS, PDSO16
PHILIPS

74AC11253DR

AC SERIES, DUAL 4 LINE TO 1 LINE MULTIPLEXER, TRUE OUTPUT, PDSO16, PLASTIC, SO-16
TI

74AC11253J

IC,LOGIC MUX,DUAL,4-INPUT,AC-CMOS,DIP,16PIN,CERAMIC
TI

74AC11253N

暂无描述
TI

74AC11253N

Multiplexer, 2-Func, 4 Line Input, CMOS, PDIP16
PHILIPS

74AC11253N

Multiplexer, AC Series, 2-Func, 4 Line Input, 1 Line Output, True Output, CMOS, PDIP16
YAGEO

74AC11257

QUADRUPLE 2-LINE TO 1-LINE DATA SELECTOR/MULTIPLEXER WITH 3-STATE OUTPUTS
TI

74AC11257D

Multiplexer, 4-Func, 2 Line Input, CMOS, PDSO20
PHILIPS

74AC11257D-T

Multiplexer, AC Series, 4-Func, 2 Line Input, 1 Line Output, True Output, CMOS, PDSO20
YAGEO

74AC11257DBR

QUADRUPLE 2-LINE TO 1-LINE DATA SELECTOR/MULTIPLEXER WITH 3-STATE OUTPUTS
TI

74AC11257DBRE4

QUADRUPLE 2-LINE TO 1-LINE DATA SELECTOR/MULTIPLEXER WITH 3-STATE OUTPUTS
TI

74AC11257DBRG4

IC AC SERIES, QUAD 2 LINE TO 1 LINE MULTIPLEXER, TRUE OUTPUT, PDSO20, GREEN, PLASTIC, SSOP-20, Multiplexer/Demultiplexer
TI