74ACT11004DBR [TI]

Hex Inverters 20-SSOP -40 to 85;
74ACT11004DBR
型号: 74ACT11004DBR
厂家: TEXAS INSTRUMENTS    TEXAS INSTRUMENTS
描述:

Hex Inverters 20-SSOP -40 to 85

文件: 总5页 (文件大小:76K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
74ACT11004  
HEX INVERTER  
SCAS215B – JANAURY 1988 – REVISED JUNE 1997  
DB, DW, N, OR PW PACKAGE  
(TOP VIEW)  
Inputs Are TTL-Voltage Compatible  
Flow-Through Architecture Optimizes PCB  
Layout  
1Y  
2Y  
3Y  
GND  
GND  
GND  
GND  
4Y  
1A  
2A  
3A  
NC  
V
1
2
3
4
5
6
7
8
9
10  
20  
19  
18  
17  
16  
15  
14  
Center-Pin V  
Minimize High-Speed Switching Noise  
and GND Configurations  
CC  
EPIC (Enhanced-Performance Implanted  
CMOS) 1- m Process  
CC  
V
500-mA Typical Latch-Up Immunity at  
125°C  
CC  
NC  
13 4A  
12 5A  
Package Options Include Plastic  
Small-Outline (DW), Shrink Small-Outline  
(DB), and Thin Shrink Small-Outline (PW)  
Packages and Standard Plastic (N) 300-mil  
DIPs  
5Y  
6Y  
11  
6A  
NC – No internal connection  
description  
This device contains six independent inverters. It performs the Boolean function Y = A.  
The 74ACT11004 is characterized for operation from –40°C to 85°C.  
FUNCTION TABLE  
(each inverter)  
INPUT  
A
OUTPUT  
Y
H
L
L
H
logic symbol  
1
20  
19  
18  
13  
12  
11  
1
1Y  
1A  
2A  
3A  
4A  
5A  
6A  
2
3
8
2Y  
3Y  
4Y  
9
5Y  
6Y  
10  
This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.  
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of  
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.  
EPIC is a trademark of Texas Instruments Incorporated.  
Copyright 1997, Texas Instruments Incorporated  
PRODUCTION DATA information is current as of publication date.  
Products conform to specifications per the terms of Texas Instruments  
standard warranty. Production processing does not necessarily include  
testing of all parameters.  
1
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
74ACT11004  
HEX INVERTER  
SCAS215B – JANAURY 1988 – REVISED JUNE 1997  
logic diagram (positive logic)  
20  
19  
18  
13  
12  
11  
1
2
1A  
2A  
3A  
4A  
5A  
6A  
1Y  
2Y  
3Y  
4Y  
5Y  
6Y  
3
8
9
10  
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)  
Supply voltage range, V  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to 7 V  
CC  
Input voltage range, V (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to V  
+ 0.5 V  
+ 0.5 V  
I
CC  
CC  
Output voltage range, V (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to V  
O
Input clamp current, I (V < 0 or V > V ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20 mA  
IK  
I
I
CC  
Output clamp current, I  
(V < 0 or V > V ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA  
OK  
O O CC  
Continuous output current, I (V = 0 to V ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA  
Continuous current through V  
Package thermal impedance, θ (see Note 2): DB package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115°C/W  
O
O
CC  
CC  
or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±150 mA  
JA  
DW package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97°C/W  
N package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67°C/W  
PW package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128°C/W  
Storage temperature range, T  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C  
stg  
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and  
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not  
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.  
NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed.  
2. The package thermal impedance is calculated in accordance with JESD 51, except for through-hole packages, which use a trace  
length of zero.  
recommended operating conditions  
MIN  
4.5  
2
MAX  
UNIT  
V
V
V
V
V
V
Supply voltage  
5.5  
CC  
IH  
IL  
High-level input voltage  
Low-level input voltage  
Input voltage  
V
0.8  
V
0
0
V
V
V
I
CC  
Output voltage  
V
O
CC  
I
I
High-level output current  
Low-level output current  
Input transition rise or fall rate  
Operating free-air temperature  
–24  
24  
mA  
mA  
ns/V  
°C  
OH  
OL  
t/v  
0
10  
T
–40  
85  
A
2
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
74ACT11004  
HEX INVERTER  
SCAS215B – JANAURY 1988 – REVISED JUNE 1997  
electrical characteristics over recommended operating free-air temperature range (unless  
otherwise noted)  
T
A
= 25°C  
PARAMETER  
TEST CONDITIONS  
V
MIN  
MAX  
UNIT  
CC  
MIN  
4.4  
TYP  
MAX  
4.5 V  
5.5 V  
4.5 V  
5.5 V  
5.5 V  
4.5 V  
5.5 V  
4.5 V  
5.5 V  
5.5 V  
5.5 V  
5.5 V  
5.5 V  
5 V  
4.4  
5.4  
I
= –50 A  
OH  
5.4  
V
3.94  
4.94  
3.8  
V
OH  
OL  
I
I
I
= –24 mA  
= –75 mA  
OH  
OH  
OL  
4.8  
3.85  
0.1  
0.1  
0.1  
0.1  
0.44  
0.44  
1.65  
±1  
= 50  
A
V
0.36  
0.36  
V
I
I
= 24 mA  
= 75 mA  
OL  
OL  
I
I
V = V  
or GND  
or GND,  
±0.1  
4
A
A
I
I
CC  
CC  
V = V  
I = 0  
O
40  
CC  
I
I  
CC  
One input at 3.4 V,  
V = V or GND  
Other inputs at GND or V  
CC  
0.9  
1
mA  
pF  
C
3.5  
i
I
CC  
Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ns.  
This is the increase in supply current for each input that is at one of the specified TTL voltage levels rather than 0 V or V  
.
CC  
switching characteristics over recommended ranges of supply voltage and free-air temperature  
(unless otherwise noted) (see Figure 1)  
T
A
= 25°C  
TYP  
5.3  
FROM  
(INPUT)  
TO  
(OUTPUT)  
PARAMETER  
MIN  
MAX  
UNIT  
MIN  
1.5  
MAX  
9
t
t
1.5  
1.5  
9.7  
9.6  
PLH  
A
Y
ns  
1.5  
6.4  
8.7  
PHL  
operating characteristics, V  
= 5 V, T = 25°C  
A
CC  
PARAMETER  
TEST CONDITIONS  
= 50 pF, f = 1 MHz  
L
TYP  
UNIT  
C
Power dissipation capacitance per inverter  
C
32  
pF  
pd  
3
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
74ACT11004  
HEX INVERTER  
SCAS215B – JANAURY 1988 – REVISED JUNE 1997  
PARAMETER MEASUREMENT INFORMATION  
3 V  
0 V  
Input  
(see Note B)  
1.5 V  
1.5 V  
From Output  
Under Test  
t
t
PLH  
PHL  
C
= 50 pF  
L
500 Ω  
(see Note A)  
V
OH  
50% V  
CC  
50% V  
Output  
CC  
V
OL  
LOAD CIRCUIT  
C includes probe and jig capacitance.  
L
VOLTAGE WAVEFORMS  
NOTES: A.  
B. Input pulses are supplied by generators having the following characteristics: PRR 1 MHz, Z = 50 , t = 3 ns, t = 3 ns.  
O
r
f
C. The outputs are measured one at a time with one input transition per measurement.  
Figure 1. Load Circuit and Voltage Waveforms  
4
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
IMPORTANT NOTICE  
Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue  
any product or service without notice, and advise customers to obtain the latest version of relevant information  
to verify, before placing orders, that information being relied on is current and complete. All products are sold  
subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those  
pertaining to warranty, patent infringement, and limitation of liability.  
TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in  
accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent  
TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily  
performed, except those mandated by government requirements.  
CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF  
DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL  
APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR  
WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER  
CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO  
BE FULLY AT THE CUSTOMER’S RISK.  
In order to minimize risks associated with the customer’s applications, adequate design and operating  
safeguards must be provided by the customer to minimize inherent or procedural hazards.  
TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent  
that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other  
intellectual property right of TI covering or relating to any combination, machine, or process in which such  
semiconductor products or services might be or are used. TI’s publication of information regarding any third  
party’s products or services does not constitute TI’s approval, warranty or endorsement thereof.  
Copyright 1998, Texas Instruments Incorporated  

相关型号:

74ACT11004DBRE4

ACT SERIES, HEX 1-INPUT INVERT GATE, PDSO20, GREEN, PLASTIC, SSOP-20
TI

74ACT11004DW

HEX INVERTER
TI

74ACT11004DWG4

HEX INVERTER
TI

74ACT11004DWR

HEX INVERTER
TI

74ACT11004DWRE4

Hex Inverters 20-SOIC -40 to 85
TI

74ACT11004DWRG4

HEX INVERTER
TI

74ACT11004J

IC IC,LOGIC GATE,HEX INVERTER,ACT-CMOS,DIP,20PIN,CERAMIC, Gate
TI

74ACT11004N

HEX INVERTER
TI

74ACT11004N

Inverter, ACT Series, 6-Func, 1-Input, CMOS, PDIP20
YAGEO

74ACT11004NE4

暂无描述
TI

74ACT11004PW

HEX INVERTER
TI

74ACT11004PWE4

ACT SERIES, HEX 1-INPUT INVERT GATE, PDSO20, GREEN, PLASTIC, TSSOP-20
TI