74ACT11174DW [TI]

HEX D-TYPE FLIP-FLOP WITH CLEAR;
74ACT11174DW
型号: 74ACT11174DW
厂家: TEXAS INSTRUMENTS    TEXAS INSTRUMENTS
描述:

HEX D-TYPE FLIP-FLOP WITH CLEAR

文件: 总6页 (文件大小:77K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
ꢀ ꢁꢂ ꢃ ꢄꢅꢅꢅꢀ ꢁ  
ꢆꢇꢈ ꢉꢊ ꢋꢄꢌ ꢍꢇꢉ ꢎꢏ ꢐ ꢍꢋꢎ ꢏꢑ ꢍꢉꢒ ꢐ ꢄ ꢆꢉ ꢃ ꢏꢇ ꢂꢓ  
SCAS145 − D3435, MARCH 1990 − REVISED APRIL 1993  
DW OR N PACKAGE  
(TOP VIEW)  
Inputs Are TTL-Voltage Compatible  
Applications Include: Buffer/Storage  
Registers, Shift Registers, Pattern  
Generators  
1Q  
2Q  
CLR  
1D  
1
2
3
4
5
6
7
8
9
10  
20  
19  
18  
17  
16  
15  
14  
Fully-Buffered Outputs for Maximum  
3Q  
2D  
Isolation From External Disturbances  
GND  
GND  
GND  
GND  
4Q  
3D  
Flow-Through Architecture Optimizes  
V
CC  
PCB Layout  
V
CC  
4D  
Center-Pin V  
and GND Configurations  
Minimize High-Speed Switching Noise  
CC  
13 5D  
12 6D  
5Q  
EPICt (Enhanced-Performance Implanted  
11  
6Q  
CLK  
CMOS) 1-mm Process  
500-mA Typical Latch-Up Immunity at 125°C  
Package Options Include Plastic  
Small-Outline Packages and Standard  
Plastic 300-mil DIPs  
description  
This device contains six D-type flip-flops and is positive-edge-triggered with a direct clear input. Information at  
the D inputs meeting the setup time requirements is transferred to the outputs on the positive-going edge of the  
clock pulse. Clock triggering occurs at a particular voltage level and is not directly related to the transition time  
of the positive-going pulse. When the clock input is at either the high or low level, the D input signal has no effect  
at the output.  
The 74ACT11174 is characterized for operation from − 40°C to 85°C.  
FUNCTION TABLE  
(each flip-flop)  
INPUTS  
OUTPUT  
Q
CLR  
L
CLK  
X
D
X
H
L
L
H
L
H
H
H
L
X
Q
0
EPIC is a trademark of Texas Instruments Incorporated.  
ꢄꢢ  
Copyright 1993, Texas Instruments Incorporated  
ꢞ ꢢ ꢟ ꢞꢗ ꢘꢬ ꢚꢙ ꢝ ꢥꢥ ꢣꢝ ꢛ ꢝ ꢜ ꢢ ꢞ ꢢ ꢛ ꢟ ꢧ  
2−1  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
ꢀ ꢁꢂ ꢃ ꢄ ꢅꢅꢅ ꢀꢁ  
ꢆ ꢇꢈꢉ ꢊ ꢋꢄ ꢌꢍ ꢇꢉ ꢎ ꢏꢐ ꢍ ꢋꢎ ꢏꢑ ꢍꢉ ꢒ ꢐꢄ ꢆꢉ ꢃ ꢏꢇ ꢂꢓ  
SCAS145 − D3435, MARCH 1990 − REVISED APRIL 1993  
logic diagram (positive logic)  
logic symbol  
20  
20  
CLR  
CLK  
R
CLR  
11  
C1  
19  
18  
17  
14  
13  
12  
1
11  
1D  
2D  
3D  
4D  
5D  
6D  
1D  
1Q  
2Q  
3Q  
4Q  
5Q  
6Q  
CLK  
2
3
19  
1D  
2D  
3D  
4D  
1D  
C1  
1
2
3
8
9
8
1Q  
9
R
10  
18  
17  
14  
1D  
C1  
2Q  
3Q  
4Q  
This symbol is in accordance with ANSI/IEEE Std 91-1984  
and IEC Publication 617-12.  
R
1D  
C1  
R
1D  
C1  
R
13  
12  
1D  
5D  
6D  
5Q  
6Q  
C1  
R
1D  
10  
C1  
R
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)  
Supply voltage range, V  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 7 V  
CC  
Input voltage range, V (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to V  
+ 0.5 V  
+ 0.5 V  
I
CC  
CC  
Output voltage range, V (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to V  
O
Input clamp current, I (V < 0 or V > V ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 mA  
IK  
I
I
CC  
Output clamp current, I  
(V < 0 or V > V ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 mA  
OK  
O O CC  
Continuous output current, I (V = 0 to V ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 mA  
Continuous current through V  
O
O
CC  
CC  
or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150 mA  
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . − 65°C to 150°C  
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only and  
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not  
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.  
NOTE 1: The input and output voltage ratings may be exceeded if the input and output current ratings are observed.  
2−2  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
ꢀ ꢁꢂ ꢃ ꢄꢅꢅꢅꢀ ꢁ  
ꢆꢇꢈ ꢉꢊ ꢋꢄꢌ ꢍꢇꢉ ꢎꢏ ꢐ ꢍꢋꢎ ꢏꢑ ꢍꢉꢒ ꢐ ꢄ ꢆꢉ ꢃ ꢏꢇ ꢂꢓ  
SCAS145 − D3435, MARCH 1990 − REVISED APRIL 1993  
recommended operating conditions  
MIN  
4.5  
2
NOM  
MAX  
UNIT  
V
V
V
V
V
V
Supply voltage  
5
5.5  
CC  
IH  
IL  
High-level input voltage  
Low-level input voltage  
Input voltage  
V
0.8  
V
0
0
V
V
V
I
CC  
Output voltage  
V
O
CC  
I
High-level output current  
Low-level output current  
Input transition rise or fall rate  
Operating free-air temperature  
24  
24  
mA  
mA  
ns/V  
°C  
OH  
OL  
I
Dt/Dv  
0
10  
T
− 40  
85  
A
electrical characteristics over recommended operating free-air temperature range (unless  
otherwise noted)  
T
A
= 25°C  
PARAMETER  
TEST CONDITIONS  
V
MIN  
MAX  
UNIT  
CC  
MIN  
4.4  
TYP  
MAX  
4.5 V  
5.5 V  
4.5 V  
5.5 V  
5.5 V  
4.5 V  
5.5 V  
4.5 V  
5.5 V  
5.5 V  
5.5 V  
5.5 V  
4.4  
5.4  
I
= − 50 mA  
OH  
5.4  
3.94  
4.94  
3.8  
V
V
OH  
OL  
I
I
= − 24 mA  
= − 75 mA  
OH  
4.8  
{
3.85  
OH  
0.1  
0.1  
0.1  
0.1  
I
= 50 mA  
OL  
0.36  
0.36  
0.44  
0.44  
1.65  
1
V
V
I
I
= 24 mA  
OL  
{
= 75 mA  
OL  
I
I
V = V  
or GND  
0.1  
8
mA  
mA  
I
I
CC  
V = V  
or GND,  
I = 0  
O
80  
CC  
I
CC  
DI  
CC  
One input at 3.4 V,  
V = V or GND  
Other inputs at GND or V  
5.5 V  
5 V  
0.9  
1
mA  
pF  
CC  
C
4
i
I
CC  
Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms.  
This is the increase in supply current for each input that is at one of the specified TTL voltage levels rather than 0 V to V  
.
CC  
timing requirements over recommended ranges of supply voltage and operating free-air  
temperature (unless otherwise noted) (see Figure 1)  
T
= 25°C  
A
MIN  
MAX  
UNIT  
MIN  
0
MAX  
f
t
Clock frequency  
Pulse duration  
110  
0
4
110  
MHz  
clock  
CLR low  
4
ns  
w
CLK high or low  
Data  
4.5  
4
4.5  
4
t
t
Setup time before CLK↑  
Hold time after CLK↑  
ns  
ns  
su  
CLR inactive  
1
1
0.5  
0.5  
h
2−3  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
ꢀ ꢁꢂ ꢃ ꢄ ꢅꢅꢅ ꢀꢁ  
ꢆ ꢇꢈꢉ ꢊ ꢋꢄ ꢌꢍ ꢇꢉ ꢎ ꢏꢐ ꢍ ꢋꢎ ꢏꢑ ꢍꢉ ꢒ ꢐꢄ ꢆꢉ ꢃ ꢏꢇ ꢂꢓ  
SCAS145 − D3435, MARCH 1990 − REVISED APRIL 1993  
switching characteristics over recommended ranges of supply voltage and operating free-air  
temperature (unless otherwise noted) (see Figure 1)  
T
A
= 25°C  
TYP  
135  
7.5  
FROM  
(INPUT)  
TO  
(OUTPUT)  
PARAMETER  
MIN  
MAX  
UNIT  
MIN  
110  
3.4  
3.1  
3.7  
MAX  
f
t
t
t
110  
3.4  
3.1  
3.7  
MHz  
ns  
max  
PHL  
PLH  
PHL  
Any Q  
Any Q  
11.4  
7.9  
12.6  
8.7  
11  
CLR  
CLK  
5.8  
ns  
7.2  
9.9  
operating characteristics, V  
= 5 V, T = 25°C  
A
CC  
PARAMETER  
TEST CONDITIONS  
= 50 pF, f = 1 MHz  
L
TYP  
UNIT  
C
Power dissipation capacitance  
Outputs enabled  
C
30  
pF  
pd  
PARAMETER MEASUREMENT INFORMATION  
From Output  
Under Test  
t
w
3 V  
C
= 50 pF  
L
500 Ω  
(see Note A)  
Input  
1.5 V  
1.5 V  
0 V  
VOLTAGE WAVEFORMS  
LOAD CIRCUIT  
3 V  
0 V  
Input  
(see Note B)  
1.5 V  
1.5 V  
3 V  
0 V  
Timing Input  
(see Note B)  
t
t
PHL  
PLH  
1.5 V  
V
OH  
In-Phase  
Output  
50% V  
CC  
t
50% V  
50% V  
h
CC  
t
V
OL  
su  
3 V  
0 V  
t
PLH  
t
1.5 V  
1.5 V  
PHL  
Data Input  
V
OH  
Out-of-Phase  
Output  
50% V  
CC  
CC  
V
OL  
VOLTAGE WAVEFORMS  
VOLTAGE WAVEFORMS  
NOTES: A. C includes probe and jig capacitance.  
L
B. All input pulses are supplied by generators having the following characteristics: PRR 10 MHz, Z = 50 , t = 3 ns, t = 3 ns.  
O
r
f
C. The outputs are measured one at a time with one input transition per measurement.  
Figure 1. Load Circuit and Voltage Waveforms  
2−4  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
PACKAGE OPTION ADDENDUM  
www.ti.com  
24-Jun-2005  
PACKAGING INFORMATION  
Orderable Device  
Status (1)  
Package Package  
Pins Package Eco Plan (2) Lead/Ball Finish MSL Peak Temp (3)  
Qty  
Type  
SOIC  
SOIC  
SOIC  
PDIP  
PDIP  
Drawing  
DW  
DW  
DW  
N
74ACT11174DW  
74ACT11174DWR  
74ACT11174DWR  
74ACT11174N  
OBSOLETE  
OBSOLETE  
OBSOLETE  
OBSOLETE  
OBSOLETE  
20  
20  
20  
20  
20  
TBD  
TBD  
TBD  
TBD  
TBD  
Call TI  
Call TI  
Call TI  
Call TI  
Call TI  
Call TI  
Call TI  
Call TI  
Call TI  
Call TI  
74ACT11174N  
N
(1) The marketing status values are defined as follows:  
ACTIVE: Product device recommended for new designs.  
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.  
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in  
a new design.  
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.  
OBSOLETE: TI has discontinued the production of the device.  
(2)  
Eco Plan  
-
The planned eco-friendly classification: Pb-Free (RoHS) or Green (RoHS  
&
no Sb/Br)  
-
please check  
http://www.ti.com/productcontent for the latest availability information and additional product content details.  
TBD: The Pb-Free/Green conversion plan has not been defined.  
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements  
for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered  
at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.  
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame  
retardants (Br or Sb do not exceed 0.1% by weight in homogeneous material)  
(3)  
MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder  
temperature.  
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is  
provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the  
accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take  
reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on  
incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited  
information may not be available for release.  
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI  
to Customer on an annual basis.  
Addendum-Page 1  
IMPORTANT NOTICE  
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements,  
and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should  
obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are  
sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment.  
TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard  
warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where  
mandated by government requirements, testing of all parameters of each product is not necessarily performed.  
TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and  
applications using TI components. To minimize the risks associated with customer products and applications, customers should provide  
adequate design and operating safeguards.  
TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right,  
or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information  
published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a  
warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual  
property of the third party, or a license from TI under the patents or other intellectual property of TI.  
Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied  
by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive  
business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional  
restrictions.  
Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all  
express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not  
responsible or liable for any such statements.  
TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably  
be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing  
such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and  
acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products  
and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be  
provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in  
such safety-critical applications.  
TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are  
specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military  
specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at  
the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use.  
TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are  
designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated  
products in automotive applications, TI will not be responsible for any failure to meet such requirements.  
Following are URLs where you can obtain information on other Texas Instruments products and application solutions:  
Products  
Applications  
Audio  
Amplifiers  
amplifier.ti.com  
dataconverter.ti.com  
www.dlp.com  
www.ti.com/audio  
Data Converters  
DLP® Products  
Automotive  
www.ti.com/automotive  
www.ti.com/communications  
Communications and  
Telecom  
DSP  
dsp.ti.com  
Computers and  
Peripherals  
www.ti.com/computers  
Clocks and Timers  
Interface  
www.ti.com/clocks  
interface.ti.com  
logic.ti.com  
Consumer Electronics  
Energy  
www.ti.com/consumer-apps  
www.ti.com/energy  
Logic  
Industrial  
www.ti.com/industrial  
Power Mgmt  
Microcontrollers  
RFID  
power.ti.com  
Medical  
www.ti.com/medical  
microcontroller.ti.com  
www.ti-rfid.com  
Security  
www.ti.com/security  
Space, Avionics &  
Defense  
www.ti.com/space-avionics-defense  
RF/IF and ZigBee® Solutions www.ti.com/lprf  
Video and Imaging  
Wireless  
www.ti.com/video  
www.ti.com/wireless-apps  
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265  
Copyright © 2010, Texas Instruments Incorporated  

相关型号:

74ACT11174DWR

6-Bit Positive-Edge-Triggered D-Type Flip-Flops With Clear 20-SOIC -40 to 85
TI

74ACT11174J

IC,FLIP-FLOP,HEX,D TYPE,ACT-CMOS,DIP,20PIN,CERAMIC
TI

74ACT11174N

D Flip-Flop, 6-Func, Positive Edge Triggered, CMOS, PDIP20
PHILIPS

74ACT11174N

6-Bit Positive-Edge-Triggered D-Type Flip-Flops With Clear 20-PDIP -40 to 85
TI

74ACT11175

QUADRUPLE D-TYPE FLIP-FLOP WITH CLEAR
TI

74ACT11175D

IC,FLIP-FLOP,QUAD,D TYPE,ACT-CMOS,SOP,20PIN,PLASTIC
TI

74ACT11175D

D Flip-Flop, ACT Series, 1-Func, Positive Edge Triggered, 4-Bit, Complementary Output, CMOS, PDSO20
YAGEO

74ACT11175D

D Flip-Flop, 4-Func, Positive Edge Triggered, CMOS, PDSO20
PHILIPS

74ACT11175D-T

D Flip-Flop, ACT Series, 1-Func, Positive Edge Triggered, 4-Bit, Complementary Output, CMOS, PDSO20
YAGEO

74ACT11175DW

D Flip-Flop,
ROCHESTER

74ACT11175DW

Quadruple D-Type Flip-Flops With Clear 20-SOIC -40 to 85
TI

74ACT11175DWR

ACT SERIES, POSITIVE EDGE TRIGGERED D FLIP-FLOP, COMPLEMENTARY OUTPUT, PDSO20, PLASTIC, SO-20
TI