74ACT11245NT [TI]

OCTAL BUS TRANSCEIVER WITH 3-STATE OUTPUTS; 八路总线收发器与3态输出
74ACT11245NT
型号: 74ACT11245NT
厂家: TEXAS INSTRUMENTS    TEXAS INSTRUMENTS
描述:

OCTAL BUS TRANSCEIVER WITH 3-STATE OUTPUTS
八路总线收发器与3态输出

总线驱动器 总线收发器 逻辑集成电路 输出元件
文件: 总6页 (文件大小:109K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
74ACT11245  
OCTAL BUS TRANSCEIVER  
WITH 3-STATE OUTPUTS  
SCAS031C – JULY 1987 – REVISED APRIL 1996  
DB, DW, NT, OR PW PACKAGE  
(TOP VIEW)  
3-State Outputs Drive Bus Lines Directly  
Inputs Are TTL-Voltage Compatible  
Flow-Through Architecture Optimizes  
PCB Layout  
A1  
A2  
A3  
DIR  
1
24  
2
23 B1  
22 B2  
Center-Pin V  
Minimize High-Speed Switching Noise  
and GND Configurations  
3
CC  
4
21  
20  
19  
18  
17  
16  
15  
14  
13  
A4  
B3  
B4  
V
5
GND  
GND  
GND  
GND  
A5  
A6  
A7  
A8  
EPIC (Enhanced-Performance Implanted  
CMOS) 1- m Process  
6
CC  
7
V
CC  
500-mA Typical Latch-Up Immunity at  
125°C  
8
B5  
B6  
B7  
B8  
OE  
9
Package Options Include Plastic  
Small-Outline (DW), Shrink Small-Outline  
(DB), and Thin Shrink Small-Outline (PW)  
Packages, and Standard Plastic 300-mil  
DIPs (NT)  
10  
11  
12  
description  
The octal bus transceiver is designed for asynchronous two-way communication between data buses. The  
control-function implementation minimizes external timing requirements.  
The device allows data transmission from the A bus to the B bus or from the B bus to the A bus, depending on  
the logic level at the direction-control (DIR) input. The output-enable (OE) input can be used to disable the  
device so that the buses are effectively isolated.  
The 74ACT11245 is characterized for operation from –40°C to 85°C.  
FUNCTION TABLE  
OUTPUT  
ENABLE  
OE  
DIRECTION  
CONTROL  
DIR  
OUTPUT  
L
L
L
H
X
B data to A bus  
A data to B bus  
Isolation  
H
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of  
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.  
EPIC is a trademark of Texas Instruments Incorporated.  
Copyright 1996, Texas Instruments Incorporated  
PRODUCTION DATA information is current as of publication date.  
Products conform to specifications per the terms of Texas Instruments  
standard warranty. Production processing does not necessarily include  
testing of all parameters.  
1
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
74ACT11245  
OCTAL BUS TRANSCEIVER  
WITH 3-STATE OUTPUTS  
SCAS031C – JULY 1987 – REVISED APRIL 1996  
logic symbol  
13  
24  
OE  
G3  
DIR  
3 EN1 [BA]  
3 EN2 [AB]  
1
23  
B1  
A1  
1
2
2
22  
21  
20  
17  
16  
15  
14  
B2  
B3  
B4  
B5  
B6  
B7  
B8  
A2  
A3  
A4  
A5  
A6  
A7  
A8  
3
4
9
10  
11  
12  
This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.  
logic diagram (positive logic)  
24  
1
DIR  
A1  
A2  
A3  
A4  
A5  
A6  
A7  
A8  
13  
23  
22  
21  
20  
17  
16  
15  
14  
OE  
B1  
B2  
B3  
B4  
B5  
B6  
B7  
B8  
2
3
4
9
10  
11  
12  
2
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
74ACT11245  
OCTAL BUS TRANSCEIVER  
WITH 3-STATE OUTPUTS  
SCAS031C – JULY 1987 – REVISED APRIL 1996  
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)  
Supply voltage range, V  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to 7 V  
CC  
Input voltage range, V (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to V  
+ 0.5 V  
+ 0.5 V  
I
CC  
CC  
Output voltage range, V (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to V  
O
Input clamp current, I (V < 0 or V > V ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20 mA  
IK  
I
I
CC  
Output clamp current, I  
(V < 0 or V > V ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA  
OK  
O O CC  
Continuous output current, I (V = 0 to V ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA  
Continuous current through V  
Maximum power dissipation at T = 55°C (in still air) (see Note 2): DB package . . . . . . . . . . . . . . . . . . 0.65 W  
O
O
CC  
CC  
or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±200 mA  
A
DW package . . . . . . . . . . . . . . . . . . 1.7 W  
NT package . . . . . . . . . . . . . . . . . . . 1.3 W  
PW package . . . . . . . . . . . . . . . . . . . 0.7 W  
Storage temperature range, T  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C  
stg  
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and  
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not  
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.  
NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed.  
2. The maximum package power dissipation is calculated using a junction temperature of 150 C and a board trace length of 750 mils,  
except for the NT package, which has a trace length of zero.  
recommended operating conditions  
MIN  
4.5  
2
MAX  
UNIT  
V
V
V
V
V
V
Supply voltage  
5.5  
CC  
IH  
IL  
High-level input voltage  
Low-level input voltage  
Input voltage  
V
0.8  
V
0
0
V
V
V
I
CC  
Output voltage  
V
O
CC  
I
I
High-level output current  
Low-level output current  
Input transition rise or fall rate  
Operating free-air temperature  
24  
24  
mA  
mA  
ns/V  
°C  
OH  
OL  
t/ v  
0
10  
T
–40  
85  
A
3
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
74ACT11245  
OCTAL BUS TRANSCEIVER  
WITH 3-STATE OUTPUTS  
SCAS031C – JULY 1987 – REVISED APRIL 1996  
electrical characteristics over recommended operating free-air temperature range (unless  
otherwise noted)  
T
A
= 25°C  
PARAMETER  
TEST CONDITIONS  
V
MIN  
MAX  
UNIT  
CC  
MIN  
4.4  
TYP  
MAX  
4.5 V  
5.5 V  
4.5 V  
5.5 V  
5.5 V  
4.5 V  
5.5 V  
4.5 V  
5.5 V  
5.5 V  
5.5 V  
5.5 V  
5.5 V  
5.5 V  
5 V  
4.4  
5.4  
I
= –50 A  
OH  
5.4  
3.94  
4.94  
3.8  
V
V
OH  
I
I
I
= –24 mA  
= –75 mA  
OH  
OH  
OL  
4.8  
3.85  
0.1  
0.1  
0.1  
0.1  
0.44  
0.44  
1.65  
±5  
= 50  
A
0.36  
0.36  
V
V
OL  
I
I
= 24 mA  
= 75 mA  
OL  
OL  
I
I
I
A or B ports  
OE or DIR  
V
= V or GND  
CC  
±0.5  
±0.1  
8
A
A
OZ  
O
V = V  
or GND  
or GND,  
±1  
I
I
CC  
CC  
V = V  
I = 0  
O
80  
A
CC  
I
I
§
One input at 3.4 V, Other inputs at GND or V  
CC  
0.9  
1
mA  
pF  
pF  
CC  
C
C
V = V  
or GND  
4
i
I
CC  
= V or GND  
CC  
V
5 V  
12  
o
O
§
Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms.  
For I/O ports, the parameter I includes the input leakage current.  
OZ  
This is the increase in supply current for each input that is at one of the specified TTL voltage levels rather than 0 V or V  
.
CC  
switching characteristics over recomended ranges of supply voltage and operating free-air  
temperature (unless otherwise noted) (see Figure 1)  
T
A
= 25°C  
TYP  
6.2  
FROM  
(INPUT)  
TO  
(OUTPUT)  
PARAMETER  
MIN  
MAX  
UNIT  
ns  
MIN  
1.5  
1.5  
1.5  
1.5  
1.5  
1.5  
MAX  
9.2  
t
t
t
t
t
t
1.5  
1.5  
1.5  
1.5  
1.5  
1.5  
10  
9.1  
PLH  
PHL  
PZH  
PZL  
PHZ  
PLZ  
A or B  
B or A  
A or B  
A or B  
5.4  
8.6  
8.1  
12  
13.2  
12.9  
12.9  
13.9  
ns  
OE  
OE  
8.2  
11.7  
11.8  
12.9  
9.3  
ns  
9.8  
operating characteristics, V  
= 5 V, T = 25°C  
A
CC  
PARAMETER  
TEST CONDITIONS  
= 50 pF, f = 1 MHz  
L
TYP  
66  
UNIT  
Outputs enabled  
Outputs disabled  
C
Power dissipation capacitance per transceiver  
C
pF  
pd  
19  
4
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
74ACT11245  
OCTAL BUS TRANSCEIVER  
WITH 3-STATE OUTPUTS  
SCAS031C – JULY 1987 – REVISED APRIL 1996  
PARAMETER MEASUREMENT INFORMATION  
2 × V  
CC  
Open  
GND  
TEST  
S1  
S1  
t
/t  
Open  
PLH PHL  
/t  
500 Ω  
From Output  
Under Test  
t
2 × V  
CC  
GND  
PLZ PZL  
t
/t  
PHZ PZH  
C
= 50 pF  
L
500 Ω  
(see Note A)  
LOAD CIRCUIT  
Output  
Control  
(low-level  
enabling)  
3 V  
0 V  
1.5 V  
1.5 V  
t
PZL  
3 V  
0 V  
t
PLZ  
Output  
Waveform 1  
V
CC  
Input  
1.5 V  
1.5 V  
50% V  
CC  
20% V  
S1 at 2 × V  
(see Note B)  
CC  
CC  
CC  
V
V
OL  
t
PLH  
t
PHZ  
t
PHL  
t
PZH  
Output  
Waveform 2  
S1 at GND  
V
OH  
OH  
0 V  
80% V  
50% V  
50% V  
Output  
CC  
CC  
50% V  
CC  
V
OL  
(see Note B)  
VOLTAGE WAVEFORMS  
C includes probe and jig capacitance.  
L
VOLTAGE WAVEFORMS  
NOTES: A.  
B. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control.  
Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control.  
C. All input pulses are supplied by generators having the following characteristics: PRR 1 MHz, Z = 50 , t = 3 ns, t = 3 ns.  
O
r
f
D. The outputs are measured one at a time with one input transition per measurement.  
Figure 1. Load Circuit and Voltage Waveforms  
5
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
IMPORTANT NOTICE  
Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue  
any product or service without notice, and advise customers to obtain the latest version of relevant information  
to verify, before placing orders, that information being relied on is current and complete. All products are sold  
subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those  
pertaining to warranty, patent infringement, and limitation of liability.  
TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in  
accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent  
TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily  
performed, except those mandated by government requirements.  
CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF  
DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL  
APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR  
WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER  
CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO  
BE FULLY AT THE CUSTOMER’S RISK.  
In order to minimize risks associated with the customer’s applications, adequate design and operating  
safeguards must be provided by the customer to minimize inherent or procedural hazards.  
TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent  
that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other  
intellectual property right of TI covering or relating to any combination, machine, or process in which such  
semiconductor products or services might be or are used. TI’s publication of information regarding any third  
party’s products or services does not constitute TI’s approval, warranty or endorsement thereof.  
Copyright 1998, Texas Instruments Incorporated  

相关型号:

74ACT11245NTE4

OCTAL BUS TRANSCEIVER WITH 3-STATE OUTPUTS
TI

74ACT11245PW

OCTAL BUS TRANSCEIVER WITH 3-STATE OUTPUTS
TI

74ACT11245PWE4

ACT SERIES, 8-BIT TRANSCEIVER, TRUE OUTPUT, PDSO24, GREEN, PLASTIC, TSSOP-24
TI

74ACT11245PWG4

ACT SERIES, 8-BIT TRANSCEIVER, TRUE OUTPUT, PDSO24, GREEN, PLASTIC, TSSOP-24
TI

74ACT11245PWLE

OCTAL BUS TRANSCEIVER WITH 3-STATE OUTPUTS
TI

74ACT11245PWR

OCTAL BUS TRANSCEIVER WITH 3-STATE OUTPUTS
TI

74ACT11245PWRE4

OCTAL BUS TRANSCEIVER WITH 3-STATE OUTPUTS
TI

74ACT11245PWRG4

OCTAL BUS TRANSCEIVER WITH 3-STATE OUTPUTS
TI

74ACT11250D

Multiplexer, 1-Func, 16 Line Input, CMOS, PDSO24
PHILIPS

74ACT11250N

Multiplexer, ACT Series, 1-Func, 16 Line Input, 1 Line Output, Inverted Output, CMOS, PDIP24
YAGEO

74ACT11251

8-INPUT MULTIPLEXER
NXP

74ACT11251D

8-INPUT MULTIPLEXER
NXP