74ACT11352  
DUAL 4–LINE TO 1–LINE DATA SELECTOR/MULTIPLEXER  
SCAS168 – DECEMBER 1991 – REVISED APRIL 1993  
D OR N PACKAGE  
Inputs Are TTL-Voltage Compatible  
Permit Multiplexing From N Lines to 1 Line  
Perform Parallel-to-Serial Conversion  
(TOP VIEW)  
1C0  
1C1  
1C2  
1C3  
A
B
1Y  
GND  
2Y  
1OE  
2OE  
2C3  
1
2
3
4
5
6
7
8
16  
15  
14  
13  
12  
11  
10  
9
Strobe Line Provided for Cascading  
(N Lines to N Lines)  
Flow-Through Architecture Optimizes PCB  
V
CC  
Layout  
2C0  
2C1  
2C2  
Center-Pin V  
and GND Pin Configurations  
Minimize High-Speed Switching Noise  
CC  
EPIC (Enhanced-Performance Implanted  
CMOS) 1-µm Process  
500-mA Typical Latch-Up Immunity at 125°C  
Package Options Include Plastic  
Small-Outline Packages, and Standard  
Plastic 300-mil DIPs  
description  
Each of these data selectors/multiplexers contains inverters and drivers to supply full binary-decoding data  
selection to the AND-OR gates. Separate strobe output-enable (OE) inputs are provided for each of the two  
four-line sections.  
The 74ACT11352 is characterized for operation from 40°C to 85°C.  
FUNCTION TABLE  
(each multiplexer)  
SELECT INPUTS  
DATA INPUTS  
STROBE OUTPUT  
OE  
H
L
Y
H
H
L
B
X
L
A
X
L
C0  
X
L
C1  
X
X
X
L
C2  
X
X
X
X
X
L
C3  
X
X
X
X
X
X
X
L
L
L
H
X
X
X
X
X
X
L
L
H
H
L
L
H
L
L
H
X
X
X
X
L
H
H
H
H
L
H
L
L
H
X
X
L
H
H
L
H
L
H
L
EPIC is a trademark of Texas Instruments Incorporated.  
Copyright 1993, Texas Instruments Incorporated  
PRODUCTION DATA information is current as of publication date.  
Products conform to specifications per the terms of Texas Instruments  
standard warranty. Production processing does not necessarily include  
testing of all parameters.  
1
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
74ACT11352  
DUAL 4–LINE TO 1–LINE DATA SELECTOR/MULTIPLEXER  
SCAS168 – DECEMBER 1991 – REVISED APRIL 1993  
logic symbol  
1
A
B
0
1
0
3
2
G
6
MUX  
EN  
0
1OE  
1C0  
1C1  
1C2  
1C3  
16  
15  
14  
13  
3
5
1
1Y  
2Y  
2
3
7
2OE  
2C0  
2C1  
2C2  
2C3  
11  
10  
9
8
This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.  
2
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
74ACT11352  
DUAL 4–LINE TO 1–LINE DATA SELECTOR/MULTIPLEXER  
SCAS168 – DECEMBER 1991 – REVISED APRIL 1993  
logic diagram (positive logic)  
6
1OE  
16  
1C0  
1C1  
1C2  
15  
14  
13  
3
1Y  
Data 1  
1C3  
B
2
Select  
1
A
11  
10  
9
2C0  
2C1  
2C2  
2C3  
2OE  
Data 2  
5
2Y  
8
7
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)  
Supply voltage range, V  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 V to 7 V  
CC  
Input voltage range, V (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 V to V  
+ 0.5 V  
+ 0.5 V  
I
CC  
CC  
Output voltage range, V (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 V to V  
O
Input clamp current, I (V < 0 or V > V ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20 mA  
IK  
I
I
CC  
Output clamp current, I  
(V < 0 or V > V ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA  
OK  
O O CC  
Continuous output current, I (V = 0 to V ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA  
Continuous current through V  
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65°C to 150°C  
O
O
CC  
CC  
or GND pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±100 mA  
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and  
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not  
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.  
NOTE 1: The input and output voltage ratings may be exceeded if the input and output clamp-current ratings are observed.  
3
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
74ACT11352  
DUAL 4–LINE TO 1–LINE DATA SELECTOR/MULTIPLEXER  
SCAS168 – DECEMBER 1991 – REVISED APRIL 1993  
recommended operating conditions (see Note 2)  
MIN NOM  
MAX  
UNIT  
V
V
V
V
V
V
Supply voltage  
4.5  
2
5
5.5  
CC  
IH  
IL  
High-level input voltage  
Low-level input voltage  
Input voltage  
V
0.8  
V
0
0
V
V
V
I
CC  
Output voltage  
V
O
CC  
I
I
High-level output current  
Low-level output current  
Input transition rise or fall rate  
Operating free-air temperature  
–24  
24  
mA  
mA  
ns/V  
°C  
OH  
OL  
t/v  
0
10  
T
–40  
85  
A
NOTE 2: Unused or floating inputs must be held high or low.  
electrical characteristics over recommended operating free-air temperature range (unless  
otherwise noted)  
T
A
= 25°C  
PARAMETER  
TEST CONDITIONS  
V
MIN  
MAX  
UNIT  
CC  
MIN  
4.4  
TYP  
MAX  
4.5 V  
5.5 V  
4.5 V  
5.5 V  
5.5 V  
4.5 V  
5.5 V  
4.5 V  
5.5 V  
5.5 V  
5.5 V  
5.5 V  
4.4  
5.4  
I
= 50 µA  
OH  
5.4  
V
3.94  
4.94  
3.8  
V
OH  
OL  
I
I
I
= 24 mA  
= 75 mA  
= 50 µA  
OH  
OH  
OL  
4.8  
3.85  
0.1  
0.1  
0.1  
0.1  
V
0.36  
0.36  
0.44  
0.44  
1.65  
±1  
V
I
I
= 24 mA  
OL  
= 75 mA  
OL  
I
I
V = V  
or GND  
or GND,  
±0.1  
µA  
µA  
I
I
CC  
CC  
V = V  
I = 0  
O
8
80  
CC  
I
One input at 3.4 V,  
Other inputs at V  
I  
CC  
5.5 V  
5 V  
0.9  
1
mA  
pF  
or GND  
CC  
V = V or GND  
CC  
C
3.5  
i
I
Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms.  
This is the increase in supply current for each input that is at one of the specified TTL voltage levels rather than 0 V or V  
.
CC  
switching characteristics over recommended operating free-air temperature range,  
V
= 5 V ± 0.5 V (unless otherwise noted) (see Figure 1)  
CC  
T
A
= 25°C  
TYP  
5.3  
FROM  
(INPUT)  
TO  
(OUTPUT)  
PARAMETER  
MIN  
MAX  
UNIT  
ns  
MIN  
2
MAX  
7.8  
9.3  
7.2  
7.8  
5.5  
7.6  
t
t
t
t
t
t
2
2.9  
2.1  
3.3  
2
8.6  
10.7  
8.2  
8.9  
6
PLH  
PHL  
PLH  
PHL  
PLH  
PHL  
A or B  
Any C  
OE  
Y
Y
Y
2.9  
2.1  
3.3  
2
6.7  
5
ns  
6.3  
4.2  
ns  
2.5  
5.5  
2.5  
8.3  
4
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
74ACT11352  
DUAL 4–LINE TO 1–LINE DATA SELECTOR/MULTIPLEXER  
SCAS168 – DECEMBER 1991 – REVISED APRIL 1993  
operating characteristics, V  
= 5 V, T = 25°C  
A
CC  
PARAMETER  
Power dissipation capacitance  
TEST CONDITIONS  
= 50 pF, f = 1 MHz  
L
TYP  
UNIT  
C
C
30  
pF  
pd  
PARAMETER MEASUREMENT INFORMATION  
From Output  
Under Test  
C
= 50 pF  
L
500 Ω  
(see Note A)  
LOAD CIRCUIT  
3 V  
0
Input  
(see Note B)  
1.5 V  
1.5 V  
t
PHL  
t
PLH  
V
OH  
Output  
50% V  
50% V  
CC  
CC  
OL  
V
VOLTAGE WAVEFORMS  
PROPAGATION DELAY TIMES  
NOTES: A. C includes probe and jig capacitance.  
L
B. Input pulses are supplied by generators having the following characteristics: PRR 10 MHz, Z = 50 , t = 3 ns, t = 3 ns.  
O
r
f
C. The outputs are measured one at a time with one input transition per measurement.  
Figure 1. Load Circuit and Voltage Waveforms  
5
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
IMPORTANT NOTICE  
Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue  
any product or service without notice, and advise customers to obtain the latest version of relevant information  
to verify, before placing orders, that information being relied on is current and complete. All products are sold  
subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those  
pertaining to warranty, patent infringement, and limitation of liability.  
TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in  
accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent  
TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily  
performed, except those mandated by government requirements.  
CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF  
DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL  
APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR  
WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER  
CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO  
BE FULLY AT THE CUSTOMER’S RISK.  
In order to minimize risks associated with the customer’s applications, adequate design and operating  
safeguards must be provided by the customer to minimize inherent or procedural hazards.  
TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent  
that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other  
intellectual property right of TI covering or relating to any combination, machine, or process in which such  
semiconductor products or services might be or are used. TI’s publication of information regarding any third  
party’s products or services does not constitute TI’s approval, warranty or endorsement thereof.  
Copyright 1998, Texas Instruments Incorporated  

相关型号:

74ACT11352J

IC,LOGIC MUX,DUAL,4-INPUT,ACT-CMOS,DIP,16PIN,CERAMIC
TI

74ACT11352N

Multiplexer, ACT Series, 2-Func, 4 Line Input, 1 Line Output, Inverted Output, CMOS, PDIP16
YAGEO

74ACT11352N

Dual 4-Line To 1-Line Data Selectors/Multiplexers 16-PDIP -40 to 85
TI

74ACT11353

DUAL 1-OF-4 DATA SELECTORS/MULTIPLEXERS WITH 3-STATE OUTPUTS
TI

74ACT11353D-T

Multiplexer, ACT Series, 2-Func, 4 Line Input, 1 Line Output, Inverted Output, CMOS, PDSO16
YAGEO

74ACT11353J

Multiplexer
TI

74ACT11353N

Dual 1-Of-4 Data Selectors/Multiplexers With 3-State Outputs 16-PDIP -40 to 85
TI

74ACT11373

OCTAL TRANSPARENT D-TYPE LATCH WITH 3-STATE OUTPUTS
TI

74ACT11373D

Bus Driver, ACT Series, 1-Func, 8-Bit, True Output, CMOS, PDSO24
YAGEO

74ACT11373D-T

Bus Driver, ACT Series, 1-Func, 8-Bit, True Output, CMOS, PDSO24
YAGEO

74ACT11373DB

OCTAL TRANSPARENT D-TYPE LATCH WITH 3-STATE OUTPUTS
TI

74ACT11373DBLE

Octal Transparent D-Type Latches With 3-State Outputs 24-SSOP -40 to 85
TI