74ACT11352
DUAL 4–LINE TO 1–LINE DATA SELECTOR/MULTIPLEXER
SCAS168 – DECEMBER 1991 – REVISED APRIL 1993
D OR N PACKAGE
• Inputs Are TTL-Voltage Compatible
• Permit Multiplexing From N Lines to 1 Line
• Perform Parallel-to-Serial Conversion
(TOP VIEW)
1C0
1C1
1C2
1C3
A
B
1Y
GND
2Y
1OE
2OE
2C3
1
2
3
4
5
6
7
8
16
15
14
13
12
11
10
9
• Strobe Line Provided for Cascading
(N Lines to N Lines)
• Flow-Through Architecture Optimizes PCB
V
CC
Layout
2C0
2C1
2C2
• Center-Pin V
and GND Pin Configurations
Minimize High-Speed Switching Noise
CC
• EPIC (Enhanced-Performance Implanted
CMOS) 1-µm Process
• 500-mA Typical Latch-Up Immunity at 125°C
• Package Options Include Plastic
Small-Outline Packages, and Standard
Plastic 300-mil DIPs
description
Each of these data selectors/multiplexers contains inverters and drivers to supply full binary-decoding data
selection to the AND-OR gates. Separate strobe output-enable (OE) inputs are provided for each of the two
four-line sections.
The 74ACT11352 is characterized for operation from –40°C to 85°C.
FUNCTION TABLE
(each multiplexer)
SELECT INPUTS
DATA INPUTS
STROBE OUTPUT
OE
H
L
Y
H
H
L
B
X
L
A
X
L
C0
X
L
C1
X
X
X
L
C2
X
X
X
X
X
L
C3
X
X
X
X
X
X
X
L
L
L
H
X
X
X
X
X
X
L
L
H
H
L
L
H
L
L
H
X
X
X
X
L
H
H
H
H
L
H
L
L
H
X
X
L
H
H
L
H
L
H
L
EPIC is a trademark of Texas Instruments Incorporated.
Copyright 1993, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
1
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
74ACT11352
DUAL 4–LINE TO 1–LINE DATA SELECTOR/MULTIPLEXER
SCAS168 – DECEMBER 1991 – REVISED APRIL 1993
†
logic symbol
1
A
B
0
1
0
3
2
G
6
MUX
EN
0
1OE
1C0
1C1
1C2
1C3
16
15
14
13
3
5
1
1Y
2Y
2
3
7
2OE
2C0
2C1
2C2
2C3
11
10
9
8
†
This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.
2
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
74ACT11352
DUAL 4–LINE TO 1–LINE DATA SELECTOR/MULTIPLEXER
SCAS168 – DECEMBER 1991 – REVISED APRIL 1993
logic diagram (positive logic)
6
1OE
16
1C0
1C1
1C2
15
14
13
3
1Y
Data 1
1C3
B
2
Select
1
A
11
10
9
2C0
2C1
2C2
2C3
2OE
Data 2
5
2Y
8
7
†
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to 7 V
CC
Input voltage range, V (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to V
+ 0.5 V
+ 0.5 V
I
CC
CC
Output voltage range, V (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to V
O
Input clamp current, I (V < 0 or V > V ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20 mA
IK
I
I
CC
Output clamp current, I
(V < 0 or V > V ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA
OK
O O CC
Continuous output current, I (V = 0 to V ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA
Continuous current through V
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
O
O
CC
CC
or GND pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±100 mA
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: The input and output voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
3
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
74ACT11352
DUAL 4–LINE TO 1–LINE DATA SELECTOR/MULTIPLEXER
SCAS168 – DECEMBER 1991 – REVISED APRIL 1993
recommended operating conditions (see Note 2)
MIN NOM
MAX
UNIT
V
V
V
V
V
V
Supply voltage
4.5
2
5
5.5
CC
IH
IL
High-level input voltage
Low-level input voltage
Input voltage
V
0.8
V
0
0
V
V
V
I
CC
Output voltage
V
O
CC
I
I
High-level output current
Low-level output current
Input transition rise or fall rate
Operating free-air temperature
–24
24
mA
mA
ns/V
°C
OH
OL
∆t/∆v
0
10
T
–40
85
A
NOTE 2: Unused or floating inputs must be held high or low.
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
T
A
= 25°C
PARAMETER
TEST CONDITIONS
V
MIN
MAX
UNIT
CC
MIN
4.4
TYP
MAX
4.5 V
5.5 V
4.5 V
5.5 V
5.5 V
4.5 V
5.5 V
4.5 V
5.5 V
5.5 V
5.5 V
5.5 V
4.4
5.4
I
= –50 µA
OH
5.4
V
3.94
4.94
3.8
V
OH
OL
I
I
I
= –24 mA
= –75 mA
= 50 µA
OH
OH
OL
4.8
†
3.85
0.1
0.1
0.1
0.1
V
0.36
0.36
0.44
0.44
1.65
±1
V
I
I
= 24 mA
OL
†
= 75 mA
OL
I
I
V = V
or GND
or GND,
±0.1
µA
µA
I
I
CC
CC
V = V
I = 0
O
8
80
CC
I
One input at 3.4 V,
Other inputs at V
‡
∆I
CC
5.5 V
5 V
0.9
1
mA
pF
or GND
CC
V = V or GND
CC
C
3.5
i
I
†
‡
Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms.
This is the increase in supply current for each input that is at one of the specified TTL voltage levels rather than 0 V or V
.
CC
switching characteristics over recommended operating free-air temperature range,
V
= 5 V ± 0.5 V (unless otherwise noted) (see Figure 1)
CC
T
A
= 25°C
TYP
5.3
FROM
(INPUT)
TO
(OUTPUT)
PARAMETER
MIN
MAX
UNIT
ns
MIN
2
MAX
7.8
9.3
7.2
7.8
5.5
7.6
t
t
t
t
t
t
2
2.9
2.1
3.3
2
8.6
10.7
8.2
8.9
6
PLH
PHL
PLH
PHL
PLH
PHL
A or B
Any C
OE
Y
Y
Y
2.9
2.1
3.3
2
6.7
5
ns
6.3
4.2
ns
2.5
5.5
2.5
8.3
4
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
74ACT11352
DUAL 4–LINE TO 1–LINE DATA SELECTOR/MULTIPLEXER
SCAS168 – DECEMBER 1991 – REVISED APRIL 1993
operating characteristics, V
= 5 V, T = 25°C
A
CC
PARAMETER
Power dissipation capacitance
TEST CONDITIONS
= 50 pF, f = 1 MHz
L
TYP
UNIT
C
C
30
pF
pd
PARAMETER MEASUREMENT INFORMATION
From Output
Under Test
C
= 50 pF
L
500 Ω
(see Note A)
LOAD CIRCUIT
3 V
0
Input
(see Note B)
1.5 V
1.5 V
t
PHL
t
PLH
V
OH
Output
50% V
50% V
CC
CC
OL
V
VOLTAGE WAVEFORMS
PROPAGATION DELAY TIMES
NOTES: A. C includes probe and jig capacitance.
L
B. Input pulses are supplied by generators having the following characteristics: PRR ≤ 10 MHz, Z = 50 Ω, t = 3 ns, t = 3 ns.
O
r
f
C. The outputs are measured one at a time with one input transition per measurement.
Figure 1. Load Circuit and Voltage Waveforms
5
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
IMPORTANT NOTICE
Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue
any product or service without notice, and advise customers to obtain the latest version of relevant information
to verify, before placing orders, that information being relied on is current and complete. All products are sold
subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those
pertaining to warranty, patent infringement, and limitation of liability.
TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in
accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent
TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily
performed, except those mandated by government requirements.
CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF
DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL
APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR
WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER
CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO
BE FULLY AT THE CUSTOMER’S RISK.
In order to minimize risks associated with the customer’s applications, adequate design and operating
safeguards must be provided by the customer to minimize inherent or procedural hazards.
TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent
that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other
intellectual property right of TI covering or relating to any combination, machine, or process in which such
semiconductor products or services might be or are used. TI’s publication of information regarding any third
party’s products or services does not constitute TI’s approval, warranty or endorsement thereof.
Copyright 1998, Texas Instruments Incorporated
相关型号:
![](http://pdffile.icpdf.com/pdf2/p00230/img/page/74ACT11352D-_1350764_files/74ACT11352D-_1350764_1.jpg)
![](http://pdffile.icpdf.com/pdf2/p00230/img/page/74ACT11352D-_1350764_files/74ACT11352D-_1350764_2.jpg)
74ACT11352N
Multiplexer, ACT Series, 2-Func, 4 Line Input, 1 Line Output, Inverted Output, CMOS, PDIP16
YAGEO
![](http://pdffile.icpdf.com/pdf2/p00287/img/page/74ACT11353D-_1743211_files/74ACT11353D-_1743211_1.jpg)
![](http://pdffile.icpdf.com/pdf2/p00287/img/page/74ACT11353D-_1743211_files/74ACT11353D-_1743211_2.jpg)
74ACT11353D-T
Multiplexer, ACT Series, 2-Func, 4 Line Input, 1 Line Output, Inverted Output, CMOS, PDSO16
YAGEO
©2020 ICPDF网 联系我们和版权申明