BQ20Z80DBT [TI]

SBS 1.1-COMPLIANT GAS GAUGE ENABLED WITH IMPEDANCE TRACK TECHNOLOGY FOR USE WITH THE bq29312A; SBS 1.1标准的电量监测计启用Impedance Track技术为使用的bq29312A
BQ20Z80DBT
型号: BQ20Z80DBT
厂家: TEXAS INSTRUMENTS    TEXAS INSTRUMENTS
描述:

SBS 1.1-COMPLIANT GAS GAUGE ENABLED WITH IMPEDANCE TRACK TECHNOLOGY FOR USE WITH THE bq29312A
SBS 1.1标准的电量监测计启用Impedance Track技术为使用的bq29312A

光电二极管
文件: 总73页 (文件大小:1137K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
SBS 1.1-COMPLIANT GAS GAUGE ENABLED WITH IMPEDANCE TRACK™  
TECHNOLOGY FOR USE WITH THE bq29312A  
FEATURES  
38-Pin TSSOP (DBT)  
Patented Impedance Track™ Technology  
Accurately Measures Available Charge in  
Li-Ion and Li-Polymer Batteries  
APPLICATIONS  
Notebook PCs  
Medical and Test Equipment  
Portable Instrumentation  
Better than 1% Error Over Lifetime of the  
Battery  
Instant Accuracy – No Learning Cycle  
Required  
DESCRIPTION  
The bq20z80 SBS-compliant gas gauge IC,  
incorporating patented Impedance Track technology,  
is designed for battery-pack or in-system installation.  
The bq20z80 measures and maintains an accurate  
record of available charge in Li-ion or Li-polymer  
batteries using its integrated high-performance  
analog peripherals. The bq20z80 monitors capacity  
change, battery impedance, open-circuit voltage, and  
other critical parameters of the battery pack, and  
reports the information to the system host controller  
over a serial-communication bus. It is designed to  
work with the bq29312A analog front-end (AFE)  
protection IC to maximize functionality and safety,  
and minimize component count and cost in smart  
battery circuits.  
Supports the Smart Battery Specification SBS  
V1.1  
Works With the TI bq29312A Analog  
Front-End (AFE) Protection IC to Provide  
Complete Pack Electronics Solution  
Full Array of Programmable Voltage, Current,  
and Temperature Protection Features  
Integrated Time Base Removes Need for  
External Crystal with Optional Crystal Input  
Electronics for 7.2-V, 10.8-V or 14.4-V Battery  
Packs With Few External Components  
Based on a Powerful Low-Power RISC CPU  
Core With High-Performance Peripherals  
Integrated Field Programmable FLASH  
Memory Eliminates the Need for External  
Configuration Memory  
The Impedance Track technology continuously  
analyzes the battery impedance, resulting in superior  
gas-gauging accuracy. This enables remaining  
capacity to be calculated with discharge rate,  
temperature, and cell aging all accounted for during  
each stage of every cycle.  
Measures Charge Flow Using a  
High-Resolution, 16-Bit Integrating  
Delta-Sigma Converter  
– Better Than 0.65-nVh of Resolution  
– Self-Calibrating  
AVAILABLE OPTIONS  
PACKAGE  
TA  
– Offset Error Less Than 1-µV  
38-PIN TSSOP (DBT)  
Tube  
38-PIN TSSOP (DBT)  
Tape & Reel  
Uses 16-Bit Delta-Sigma Converter for  
Accurate Voltage and Temperature  
Measurements  
–40°C to  
85°C  
bq20z80DBT-V101(1)  
bq20z80DBTR-V101(2)  
Extensive Data Reporting Options For  
Improved System Interaction  
Optional Pulse Charging Feature for Improved  
Charge Times  
Drives 3-, 4- or 5-Segment LED Display for  
Remaining Capacity Indication  
(1) A single tube quantity is 50 units.  
(2) A single reel quantity is 2000 units  
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas  
Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.  
IMPEDANCE TRACK is a trademark of Texas Instruments.  
PRODUCTION DATA information is current as of publication date.  
Products conform to specifications per the terms of the Texas  
Instruments standard warranty. Production processing does not  
necessarily include testing of all parameters.  
Copyright © 2004–2005, Texas Instruments Incorporated  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
These devices have limited built-in ESD protection. The leads should be shorted together or the device  
placed in conductive foam during storage or handling to prevent electrostatic damage to the MOS gates.  
TSSOP (DBT)  
(TOP VIEW)  
1
2
3
38  
37  
36  
35  
34  
33  
32  
31  
VIN  
VSSD  
NC  
TS1  
TS2  
NC  
4
PU  
PRES  
SCLK  
SAFE  
VDDD  
RBI  
CLKOUT  
XCK1 / VSSA  
XCK2 / ROSC  
FILT  
5
6
7
8
VDDA  
VSSA  
VSSA  
SR1  
30  
29  
28  
9
10  
11  
12  
SDATA  
VSSD  
SAFE  
NC  
27  
26  
25  
24  
23  
22  
21  
20  
SR2  
13  
14  
15  
MRST  
XALERT  
LED1  
NC  
SMBC  
16  
17  
18  
19  
SMBD  
DISP  
LED2  
LED3  
LED4  
PFIN  
VSSD  
LED5  
NC - No internal connection  
TERMINAL FUNCTIONS  
TERMINAL  
NAME  
I/O(1)  
DESCRIPTION  
NO.  
1
VIN  
TS1  
I
I
Voltage measurement input from the AFE  
2
1st Thermistor voltage input connection to monitor temperature  
2nd Thermistor voltage input connection to monitor temperature  
Output to pull up the PRES pin for system detection  
3
TS2  
I
4
PU  
O
I
5
PRES  
SCLK  
SAFE  
VDDD  
Active low input to sense system insertion and typically requires additional ESD protection  
6
I/OD Communication clock to the AFE  
7
O
P
Active high output to enforce additional level of safety protection; e.g., fuse blow. (Inverse of pin 12)  
Positive supply for digital circuitry and I/O pins  
8
Backup power to the bq20z80 data registers during periods of low operating voltage. RBI accepts a  
storage capacitor or a battery input.  
9
RBI  
P
10  
12  
13  
14  
15  
16  
SDATA  
SAFE  
NC  
I/O  
O
Data transfer to and from the AFE  
Active low output to enforce additional level of safety protection; e.g., fuse blow. (Inverse of pin 7)  
Not used— leave floating  
Not used— leave floating  
NC  
SMBC  
SMBD  
I/OD SMBus clock open-drain bidirectional pin used to clock the data transfer to and from the bq20z80  
I/OD SMBus data open-drain bidirectional pin used to transfer address and data to and from the bq20z80  
Display control for the LEDs. This pin is typically connected to bq29312A REG via a 100-kresistor  
and a push-button switch to VSSD.  
17  
18  
DISP  
PFIN  
I
Active low input to detect secondary protector output status and allows the bq20z80 to report the  
I
status of the 2nd level protection output  
20  
21  
LED5  
LED4  
O
O
LED5 display segment that drives an external LED depending on the firmware configuration  
LED4 display segment that drives an external LED depending on the firmware configuration  
(1) I = Input, IA = Analog input, I/O = Input/output, I/OD = Input/Open-drain output, O = Output, OA = Analog output, P = Power  
2
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
TERMINAL FUNCTIONS (continued)  
TERMINAL  
I/O(1)  
DESCRIPTION  
NO.  
NAME  
LED3  
LED2  
LED1  
XALERT  
MRST  
SR2  
22  
23  
24  
25  
26  
27  
28  
31  
O
O
O
I
LED3 display segment that drives an external LED depending on the firmware configuration  
LED2 display segment that drives an external LED depending on the firmware configuration  
LED1 display segment that drives an external LED depending on the firmware configuration  
Input from bq29312A XALERT output.  
I
Master reset input that forces the device into reset when held high  
IA  
IA  
P
Connections for a small-value sense resistor to monitor the battery charge- and discharge-current flow  
Connections for a small-value sense resistor to monitor the battery charge- and discharge-current flow  
Positive supply for analog circuitry  
SR1  
VDDA  
Analog input connected to the external PLL filter components which are a 150-pF capacitor to VSSA, in  
parallel with a 61.9-kresistor and a 2200-pF capacitor in series. Place these components as close as  
possible to the bq20z80 to ensure optimal performance.  
32  
FILT  
IA  
32.768-kHz crystal oscillator output pin or connected to a 100k, 50ppm or better resistor if the internal  
oscillator is used  
33  
XCK2/ROSC  
O
34  
35  
36  
37  
XCK1/VSSA  
CLKOUT  
NC  
I
O
-
32.768-kHz crystal oscillator input pin or connected to VSSA if the internal oscillator is used  
32.768-kHz output for the bq29312. This pin should be directly connected to the AFE.  
Not used— leave floating  
NC  
-
Not used— leave floating  
11, 19,  
38  
VSSD  
VSSA  
P
P
Negative supply for digital circuitry  
Negative supply for analog circuitry.  
29, 30  
ABSOLUTE MAXIMUM RATINGS  
over operating free-air temperature range (unless otherwise noted)(1)  
RANGE  
–0.3 V to 4.1 V  
–0.3 V to 6 V  
(2)  
VDDAand VDDD relative to VSS  
Supply voltage range  
(2)  
V(IOD) relative to VSS  
Open-drain I/O pins  
(2)  
VI relative to VSS  
Input voltage range to all other pins  
Operating free-air temperature range  
Storage temperature range  
–0.3 V to VDDA + 0.3 V  
–40°C to 85°C  
TA  
Tstg  
– 65°C to 150°C  
(1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings  
only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating  
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.  
(2) VSS refers to the common node of V(SSA) and V(SSD)  
.
3
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
ELECTRICAL CHARACTERISTICS  
VDD = 3 V to 3.6 V, TA = –40°C to 85°C (unless otherwise noted)  
PARAMETER  
TEST CONDITIONS  
MIN  
TYP  
3.3  
350(1)  
8(1)  
MAX UNIT  
VDD  
IDD  
Supply voltage  
VDDA and VDDD  
No flash programming  
Sleep mode  
3
3.6  
V
Operating mode current  
µA  
µA  
I(SLP)  
VOL  
Low-power storage mode current  
Output voltage low SMBC, SMBD, SDATA, SCLK,  
SAFE, SAFE, PU  
IOL = 0.5 mA  
0.4  
0.4  
LED1 – LED5  
IOL = 10 mA  
VOH  
VIL  
Output high voltage, SMBC, SMBD, SDATA, SCLK, IOH = –1 mA  
SAFE, SAFE, PU  
VDD– 0.5  
–0.3  
Input voltage low SMBC, SMBD, SDATA, SCLK,  
XALERT, PRES, PFIN  
0.8  
V
DISP  
–0.3  
2
0.8  
6
VIH  
Input voltage high SMBC, SMBD, SDATA, SCLK,  
XALERT, PRES, PFIN  
DISP  
2
VCC + 0.3  
CIN  
Input capacitance  
5
pF  
V
V(AI1)  
V(AI2)  
Z(AI1)  
Z(AI2)  
Input voltage range VIN, TS1, TS2  
Input voltage range SR1, SR2  
VSS– 0.3  
1
VSS– 0.25  
0.25  
Input impedance SR1, SR2  
0 V–1 V  
0 V–1 V  
2.5  
8
MΩ  
MΩ  
Input impedance VIN, TS1, TS2  
(1) This value does not include the bq29312  
POWER-ON RESET  
VDD = 3 V to 3.6 V, TA = –40°C to 85°C (unless otherwise noted)  
PARAMETER  
Negative-going voltage input  
Power-on reset hysteresis  
TEST CONDITIONS  
MIN  
TYP  
2.3  
MAX  
2.5  
UNIT  
V
VIT–  
2.1  
50  
VHYS  
150  
200  
mV  
POWER ON RESET BEHAVIOR  
vs  
FREE-AIR TEMPERATURE  
2.50  
2.45  
2.40  
2.35  
2.30  
2.25  
2.20  
140  
135  
130  
125  
120  
115  
110  
105  
100  
V
V
IT-  
hys  
2.15  
2.10  
-20 -10  
0
10 20 30 40 50 60 70 80  
- Free-Air Temperature - °C  
T
A
INTEGRATING ADC (Coulomb Counter) CHARACTERISTICS  
VDD = 3 V to 3.6 V, TA = –40°C to 85°C (unless otherwise noted)  
PARAMETER  
TEST CONDITIONS  
MIN  
–0.25  
TYP  
MAX UNIT  
V(SR)  
Input voltage range, V(SR2) and V(SR1)  
V(SR) = V(SR2) – V(SR1)  
0.25  
V
V(SROS) Input offset  
INL Integral nonlinearity error  
1
µV  
0.004% 0.019%  
4
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
PLL SWITCHING CHARACTERISTICS  
VDD = 3 V to 3.6 V, TA = –40°C to 85°C (unless otherwise noted)  
PARAMETER  
TEST CONDITIONS  
0.5% frequency error  
MIN  
TYP  
MAX  
UNIT  
(1)  
t(SP)  
Start-up time  
2
5
ms  
(1) The frequency error is measured from the trimmed frequency of the internal system clock which is 128 oscillator frequency, nominally  
4.194 MHz.  
OSCILLATOR  
VDD = 3 V to 3.6 V, TA = –40°C to 85°C (unless otherwise noted)  
PARAMETER  
TEST CONDITIONS  
ROSC = 100 kΩ  
MIN  
–2%  
TYP  
0.25%  
0.25%  
MAX UNIT  
2%  
1%  
f(exo)  
Frequency error from 32.768 kHz  
ROSC = 100 k, VDD = 3.3 V  
XCK1 = 12-pF XTAL  
ROSC = 100 kΩ  
–1%  
–0.25%  
0.25%  
(1)  
f(sxo)  
Start-up time  
250  
200  
µs  
XCK1 = 12-pF XTAL  
ms  
(1) The start-up time is defined as the time it takes for the oscillator output frequency to be within 1% of the specified frequency.  
DATA FLASH MEMORY CHARACTERISTICS  
VDD = 3 V to 3.6 V, TA = –40°C to 85°C (unless otherwise noted)  
PARAMETER  
Data retention  
TEST CONDITIONS  
MIN  
(1)10  
TYP  
MAX  
UNIT  
Years  
Cycles  
ms  
tDR  
(1)  
(1)  
(1)  
Flash programming write-cycles  
Word programming time  
20,000  
t(WORDPROG)  
I(DDPROG)  
2
Flash-write supply current  
8
15  
mA  
(1) Assured by design. Not production tested  
REGISTER BACKUP  
VDD = 3 V to 3.6 V, TA = –40°C to 85°C (unless otherwise noted)  
PARAMETER  
TEST CONDITIONS  
V(RBI) > 3 V, VDD < VIT  
MIN  
TYP  
10  
MAX UNIT  
I(RBI)  
RBI data-retention input current  
RBI data-retention voltage(1)  
100  
nA  
V
V(RBI)  
1.3  
(1) Specified by design. Not production tested.  
5
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
SMBus TIMING SPECIFICATIONS  
VDD = 3 V to 3.6 V, TA = –40°C to 85°C (unless otherwise noted)  
PARAMETER  
TEST CONDITIONS  
MIN  
TYP  
MAX UNIT  
fSMB  
SMBus operating frequency  
SMBus master clock frequency  
Bus free time between start and stop  
Hold time after (repeated) start  
Repeated start setup time  
Stop setup time  
Slave mode, SMBC 50% duty cycle  
10  
100  
kHz  
fMAS  
Master mode, no clock low slave extend  
51.2  
tBUF  
4.7  
4
tHD:STA  
tSU:STA  
tSU:STO  
µs  
4.7  
4
Receive mode  
Transmit mode  
0
tHD:DAT  
Data hold time  
300  
250  
(1)25  
4.7  
(2)4  
ns  
tSU:DAT  
tTIMEOUT  
tLOW  
Data setup time  
Error signal/detect  
35  
ms  
Clock low period  
µs  
tHIGH  
Clock high period  
50  
(3)25  
(4)10  
300  
tLOW:SEXT  
tLOW:MEXT  
tF  
Cumulative clock low slave extend time  
Cumulative clock low master extend time  
Clock/data fall time  
ms  
ns  
(VILMAX– 0.15 V) to (VIHMIN + 0.15 V)  
0.9 VDD to (VILMAX – 0.15 V)  
tR  
Clock/data rise time  
1000  
(1) The bq20z80 times out when any clock low exceeds tTIMEOUT  
.
(2) tHIGH:MAX. is minimum bus idle time. SMBC = 1 for t > 50 µs causes reset of any transaction involving the bq20z80 that is in progress.  
(3) tLOW:SEXT is the cumulative time a slave device is allowed to extend the clock cycles in one message from initial start to the stop.  
(4) tLOW:MEXT is the cumulative time a master device is allowed to extend the clock cycles in one message from initial start to the stop.  
SMBus TIMING DIAGRAM  
6
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
FUNCTIONAL DESCRIPTION  
Within the functional description of the bq20z80 System Management Bus (SMBus), commands are prefixed with  
SBS. and data flash variables are prefixed with DF: and are both italicized in full. For example:  
SBS.RemainingCapacity( ) and DF:Fast Charge Current.  
OSCILLATOR FUNCTION  
The oscillator of the bq20z80 can be set up for internal or external operation. On power up, the bq20z80  
automatically attempts to start the internal oscillator. If a 100-kresistor is not connected to ROSC (pin 33), then  
it attempts to start the oscillator using an external 32.768-kHz crystal.  
NOTE:  
Install either the 100-kROSC resistor or the 12-pF, 32.768-kHz crystal. Do not  
install both.  
The performance of the internal oscillator depends on the tolerance of the 100-kresistor between RSOC (pin  
33) and VSSA (pin 34). Choose a resistor with a tolerance of ±0.1%, and 50-ppm or better temperature drift.  
Place this resistor as close as possible to the bq20z80. If a 12-pF crystal is used, place it as close as possible to  
the XCK1 (pin 34) and XCK2 (pin 33) pins. If not properly implemented, the PCB layout in this area can degrade  
oscillator performance.  
SYSTEM PRESENT OPERATION  
The bq20z80 periodically (1 s) pulls the PU output high. Connect this pin to the PRES pin of the bq20z80 via a  
resistor of approximately 5 k. The bq20z80 measures the PRES input during the PU-active period to determine  
its state.  
The bq20z80 detects that the battery is present in the system via a low state on the PRES input. When this  
occurs, the bq20z80 enters normal operating mode and sets the PRES bit in SBS.OperationStatus( ). When the  
pack is removed from the system and the PRES input is high, the bq20z80 enters the battery-removed state,  
disabling the charge and discharge FETs, and enabling the 0-V/precharging FET. If DF:Operation Cfg B [NR] is  
set, the PRES input is ignored and can be left floating.  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE SIZE (BYTES)  
0x0000 to 0xffff  
UNITS  
DEFAULT VALUE  
Operation Cfg B  
Configuration / Registers (64)  
Hex  
2
N/A  
0x6140  
GENERAL OPERATION  
The bq20z80 determines battery capacity by monitoring individual cell voltages and the amount of charge input  
or removed from a rechargeable battery. In addition, the bq20z80 measures individual cell voltages, pack  
voltage, temperature, and current using features of the bq29312A analog front end (AFE) device and calculates  
individual cell impedances using collected data.  
The bq20z80 measures charge/discharge activity by monitoring the voltage across a small-value series sense  
resistor (5 mto 20 mtyp.) between the cell stack negative terminal and the negative terminal of the battery  
pack. When an applications load is applied, impedance of each cell is measured by comparing its Open Circuit  
Voltage (OCV) obtained for the present state of charge using a predefined OCV(SOC) function with measured  
voltage under load.  
The bq20z80 interfaces with the bq29312A to perform battery protection, cell balancing, and voltage translation  
functions. The bq20z80 can accept inputs of up to two identical NTC thermistors (default is Semitec 103AT) for  
temperature measurement, or can also be configured to use its internal temperature sensor. The bq20z80 uses  
temperature to monitor the battery-pack environment.  
BATTERY PARAMETER MEASUREMENTS  
The bq20z80 uses an integrating delta-sigma analog-to-digital converter (ADC) for current measurement, and a  
second delta-sigma ADC for individual cell and battery voltage, and temperature measurement. The individual  
cell and pack voltages, SBS.CellVoltagex( ), SBS.Voltage( ), SBS.Current( ), SBS.AverageCurrent( ), and  
SBS.Temperature( ) are updated at 1-second intervals during normal operation.  
7
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
Charge and Discharge Counting  
The integrating delta-sigma ADC measures the charge/discharge flow of the battery by measuring the voltage  
drop across a small-value sense resistor between the SR1 and SR2 pins. The integrating ADC measures bipolar  
signals from -0.25 V to 0.25 V. The bq20z80 detects charge activity when VSR = V(SR1)-V(SR2) is positive and  
discharge activity when VSR = V(SR1)-V(SR2) is negative. The bq20z80 continuously integrates the signal over time,  
using an internal counter. The fundamental rate of the counter is 0.65 nVh.  
Coulomb Counter Dead Band  
The bq20z80 does not accumulate charge or discharge for gas gauging when the current input is below the  
dead-band current threshold. The threshold is programmed in DF:CC Deadband (Coulomb Counter Deadband)  
and should be set sufficiently high to prevent false signal detection with no charge or discharge flowing through  
the sense resistor.  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE SIZE (BYTES)  
0 to 255  
UNITS  
DEFAULT VALUE  
CC Deadband  
Calibration / Current (107)  
Integer  
1
294nV  
34  
Voltage  
The bq20z80 updates the individual series cell voltages through the bq29312A at one-second intervals. In Sleep  
mode the period changes from 1 s to DF:Sleep Voltage Time. The bq20z80 configures the bq29312A to connect  
the selected cell, cell offset, or bq29312A VREF to the CELL pin of the bq29312, which is required to be  
connected to VIN of the bq20z80. The internal ADC of the bq20z80 measures the voltage, scales and calibrates  
it appropriately, then reports the SBS.Voltage( ) and the individual cell voltages in SBS.CellVoltage1( ),  
SBS.CellVoltage2( ), SBS.CellVoltage3( ), and SBS.CellVoltage4( ). This data is also used to calculate the  
impedance of the cell for the Impedance Track gas-gauging when SBS.Current( ) is above 100 mA and dV/dt is  
< 1 µV/s.  
Current  
The bq20z80 uses the SR1 and SR2 inputs to measure and calculate the battery charge and discharge current.  
This value is reported via SBS.Current( ) and is updated at one-second intervals in normal mode, and at intervals  
defined by DF:Sleep Current Time in sleep mode. SBS.AverageCurrent( ) is implemented as a single-pole  
infinite-impulse response (IIR) filter with a 14.5 s time constant using SBS.Current( ) data and is also updated  
once per second.  
NAME  
CLASS / SUBCLASS  
FORMAT VALID RANGE SIZE (BYTES)  
Integer 0 to 255  
UNITS  
DEFAULT VALUE  
Sleep Current Time  
Power / Power (68)  
1
s
20  
Auto Calibration  
The bq20z80 provides an auto-calibration feature to cancel the voltage offset error across SR1 and SR2 for  
maximum charge measurement accuracy. The bq20z80 performs auto-calibration when the SMBus lines stay  
low continuously for a minimum of 5 s and SBS.Temperature( ) is within bounds of DF:Cal Inhibit Temp Low and  
DF:Cal Inhibit Temp High. The bq20z80 is capable of automatic offset calibration down to 1 µV.  
NAME  
CLASS / SUBCLASS FORMAT  
VALID RANGE  
SIZE (BYTES)  
UNITS  
DEFAULT VALUE  
Cal Inhibit Temp Low  
Cal Inhibit Temp High  
50  
Power / Power (68) Signed Int  
-400 to 1200  
2
0.1°C  
450  
Temperature  
The bq20z80 TS1 and TS2 inputs, in conjunction with two identical NTC thermistors (default are Semitec  
103AT), measure the battery environmental temperature. The bq20z80 can also be configured to use its internal  
temperature sensor. The bq20z80 updates the reported temperature each second in normal mode, and each  
DF:Sleep Voltage Time in Sleep mode, via SBS.Temperature( ) depending on the state of DF:Operation Cfg A  
[TEMP1, TEMP0].  
NAME  
CLASS / SUBCLASS  
Power / Power (68)  
FORMAT  
Integer  
Hex  
VALID RANGE SIZE (BYTES) UNITS  
DEFAULT VALUE  
Sleep Voltage Time  
Operation Cfg A  
0 to 100  
1
2
s
5
Configuration / Registers (64)  
0x0000 to 0xffff  
N/A  
0x0f29  
8
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
Gas Gauging  
The bq20z80 measures individual cell voltages, pack voltage, temperature, and current using features of the  
bq29312A AFE device. The bq20z80 determines battery state of charge by analyzing individual cell voltages  
when a time exceeding 35 minutes has passed since the batteries last charge or discharge activity. The bq20z80  
measures charge and discharge activity by monitoring the voltage across a small-value series sense resistor (5  
mto 20 mtyp.) between the cell stack negative terminal and the negative terminal of the battery pack. The  
batteries State of charge is subsequently adjusted during load or charger application using the integrated charge  
passed through the battery.  
Resistance update takes place in discharge mode, while OCV and Qmax updates take place only in relaxation  
mode. Entry and exit of each mode is controlled by ata flash (DF:) parameters in the subclass 'Gas Gauging:  
Current Thresholds' section. Charge mode is exited and Relaxation mode is entered when SBS.Current( ) goes  
below DF:Quit Current for a period of DF:Chg Relax Time. Discharge mode is entered when SBS.Current( ) goes  
below DF:Dsg Current Threshold. Discharge mode is exited and Relaxation mode is entered when SBS.Current(  
) goes above (–) DF:Quit Current threshold for a period of DF:Dsg Relax Time. Charge mode is entered when  
SBS.Current( ) goes above DF:Chg Current Threshold.  
The total battery capacity is found by comparing states of charge before and after applying the load with the  
amount of charge passed. When an applications load is applied, the impedance of each cell is measured by  
comparing the open circuit voltage (OCV) obtained from a predefined function for present state of charge with the  
measured voltage under load.  
Measurements of OCV and charge integration determine chemical state of charge and Chemical Capacity  
(Qmax). The initial DF:Qmax Pack, DF:Qmax Cell 1, DF:Qmax Cell 2, DF:Qmax Cell 3, and DF:Qmax Cell 4  
values are taken from the cell manufacturers' data sheet multiplied by the number of parallel cells, and are also  
used for the SBS.DesignCapacity( ) value in DF:Design Capacity. The bq20z80 acquires and updates the  
battery-impedance profile during normal battery usage. It uses this profile, along with state-of-charge and the  
Qmax values, to determine SBS.FullChargeCapacity( ) and SBS.RelativeStateOfCharge( ) specifically for the  
present load and temperature. SBS.FullChargeCapacity( ) is reported as capacity or energy available from a fully  
charged battery under the present load and temperature until SBS.Voltage( ) reaches the DF:Term Voltage.  
NAME  
Term Voltage  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
-32768 to 32767  
0 to 1000  
SIZE (BYTES)  
UNITS  
mV  
DEFAULT VALUE  
Gas Gauging / IT Config (80)  
Signed Int  
2
2
1
1
2
2
2
2
2
2
2
2
12000  
10  
Quit Current  
mA  
Dsg Relax Time  
Chg Relax Time  
Chg Current Threshold  
Dsg Current Threshold  
QMax Pack  
0 to 255  
s
1
Gas Gauging /  
Current Thresholds (81)  
0 to 255  
s
60  
0 to 2000  
mA  
50  
0 to 2000  
mA  
100  
4400  
4400  
4400  
4400  
4400  
4400  
Integer  
0 to 65535  
0 to 65535  
0 to 65535  
0 to 65535  
0 to 65535  
0 to 65535  
mAh  
mAh  
mAh  
mAh  
mAh  
mAh  
Qmax Cell 1  
Qmax Cell 2  
Gas Gauging / State (82)  
Qmax Cell 3  
Qmax Cell 4  
Design Capacity  
SBS Configuration / Data (48)  
Impedance Track™ Load Model  
During normal operation, the battery-impedance profile compensation of the Impedance Track algorithm can  
provide more accurate full-charge and remaining state-of-charge information if the typical load type is known.  
The two selectable options are constant current and constant power.  
DF:Load Mode VALUE  
COMPENSATION  
Constant current  
Constant power  
0x00  
0x01  
Impedance Track Load Compensation  
In order to compensate for the I x R drop near the end of discharge, the bq20z80 needs to be configured for  
whatever current (or power) will flow in the future. While it can not be exactly known, the bq20z80 can use load  
history such as the averaged current of the present discharge to make a sufficiently accurate prediction. The  
9
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
bq20z80 can be configured to use several methods of this prediction shown in Table 1, by setting the DF.Load  
Select value. Because this estimate has only a second-order effect on remaining capacity accuracy, different  
measurement based methods (0x00 to 0x03) result in only minor differences in accuracy. However, methods  
0x04-0x06 where an estimate is arbitrarily assigned by the user can result in significant error if a fixed estimate is  
far from the actual load.  
Table 1. Impedance Track Load-Compensation Settings  
DF:Load Select  
Load Mode  
Load Compensation  
Previous Discharge Average Current in DF:Avg I Last Run  
Previous Discharge Average Power in DF:Avg P Last Run  
Present Discharge Average Current  
Present Discharge Average Power  
SBS.Current( )  
0x00  
Constant Current  
Constant Power  
Constant Current  
Constant Power  
Constant Current  
Constant Power  
Constant Current  
Constant Power  
Constant Current  
Constant Power  
Constant Current  
Constant Power  
Constant Current  
Constant Power  
0x01  
0x02  
0x03  
0x04  
0x05  
0x06  
RAM.InstantPower( ) = SBS.Current( ) x SBS.Voltage( )  
SBS.AverageCurrent( )  
SBS.AveragePower( ) = SBS.AverageCurrent( ) x SBS.Voltage( )  
SBS.DesignCapacity( ) / 5  
SBS.DesignEnergy( ) / 5  
SBS.AtRate( ) (mAh)  
SBS.AtRate( ) (10mWh)  
DF:User Rate-mA  
DF:User Rate-10mWh  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
2000 to 9000  
3000 to 14000  
SIZE (BYTES)  
UNITS  
mAh  
DEFAULT VALUE  
User Rate-mAh  
User Rate-10 mWh  
Gas Gauging / IT Config (80)  
Gas Gauging / IT Config (80)  
2
2
0
0
Signed Int  
10 mWh  
Pulsed Load Compensation  
In order to take into account pulsed loads, while calculating remaining capacity until DF:Term Voltage is reached,  
bq20z80 monitors not only average load but also short load spikes. The maximum voltage deviation during a  
load spike is continuously updated during discharge and stored in DF:Delta Voltage.  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
SIZE (BYTES)  
UNITS  
DEFAULT VALUE  
Delta Voltage  
Gas Gauging / State (82)  
Integer  
-32767 to 32768  
2
mV  
0
Reserve Battery Capacity  
The bq20z80 allows an amount of capacity to be reserved in either mAh (DF:Reserve Cap-mAh) or 10 mWh  
(DF:Reserve Cap-10mWh) units between the point where SBS.RemainingCapacity( ) is reported as 0%, and the  
absolute minimum voltage, DF:Term Voltage. This enables a system to report zero energy, but still have enough  
reserve energy to perform a controlled shutdown, or to provide an extended sleep period for the host system.  
Also, if DF:Operation Cfg B [ResCap] = 0, the reserve capacity is compensated at a no-load conditions.  
However, if DF:Operation Cfg B [ResCap] = 1, then the reserve capacity is compensated at the present  
discharge rate as selected by DF:Load Select.  
NAME  
CLASS / SUBCLASS FORMAT  
VALID RANGE  
0 to 9000  
SIZE (BYTES)  
UNITS  
mAh  
DEFAULT VALUE  
Reserve Cap-mAh  
Reserve Cap-10 mWh  
2
2
0
0
Gas Gauging /  
Signed Int  
IT Config (80)  
0 to 14000  
10 mWh  
QMAX Update Conditions  
The bq20z80 updates the no-load full capacity (QMAX) when two open circuit voltage (OCV) readings are taken  
when the battery is in a relaxed state before and after charge or discharge activity. A relaxed state is achieved if  
the battery voltage has a dV/dt of < 4µV. Typically it takes 2 hrs in a charged state and 5 hrs in a discharged  
state to ensure that the dV/dt condition is satisfied. If 5 hrs is exceeded, a reading will be taken even if the dV/dt  
condition was not satisfied. This update is disqualified under the following conditions:  
10  
 
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
Temperature If SBS.Temperature( ) is outside of the range 10°C to 40°C  
Delta Capacity If the capacity change between suitable battery rest periods is less than 37%  
Voltage  
If and SBS.CellVoltage1..4( ) is within the range of 3737mV and 3800mV  
Discharge and Charge Alarms  
The bq20z80 enables SBS.BatteryStatus( ) [TDA, FD, TCA, FC] flags to be set or cleared on the following  
thresholds based on SBS.RelativeStateOfCharge( ).  
DF:Operation Cfg A  
CONDITION  
SBS.BatteryStatus( ) FLAG ACTION  
[DMODE] = 0  
[DMODE] = 1  
DF:TDA Set %  
DF:TDA Clear %  
DF:FD Set %  
Terminate_Discharge_Alarm is set  
Terminate_discharge_Alarm is cleared  
Fully_Discharged is set  
DF:FD Clear %  
DF:TCA Set %  
DF:TCA Clear %  
DF:FC Set %  
Fully_Discharged is cleared  
Terminate_Charge_Alarm is set  
Terminate_Charge_Alarm is cleared  
Fully_Charged is set  
SBS.RelativeStateOfCharge( )  
SBS.AbsoluteOfCharge( )  
DF:FC Clear %  
Fully_Charged is cleared  
The SBS.RelativeStateOfCharge( ) or SBS.AbsoluteStateOfCharge( ) based thresholds can be disabled by  
setting the value to -1%.  
The SBS.BatteryStatus( ) [TDA, FD] flags can also be set or cleared based on the level of SBS.Voltage( ). If the  
voltage settings are not used then they should be set to extreme range values.  
CONDITION  
DF:TDA Volt Threshold for a period of DF:TDA Volt Time  
DF:TDA Recovery  
SBS.BatteryStatus( ) FLAG ACTION  
Terminate_Discharge_Alarm is set  
Terminate_discharge_Alarm is cleared  
Fully_Discharged is set  
SBS.Voltage( )  
DF:FD Volt Threshold for a period of DF:FD Volt Time  
DF:FD Recovery  
Fully_Discharged is cleared  
See the Charge Termination and Protection sections of this data sheet for further details on the setting of  
Terminate_Charge_Alarm.  
VALID  
RANGE  
SIZE  
(BYTES)  
DEFAULT  
VALUE  
NAME  
CLASS / SUBCLASS  
FORMAT  
UNITS  
TDA Set %(1)  
TDA Clear%(1)  
FD Set %(1)  
6
8
2
FD Clear %(1)  
TCA Set %(1)  
TCA Clear %(1)  
FC Set %(1)  
5
Integer  
-1 to 100  
1
%
-1  
95  
-1  
SBS Configuration / Config (49)  
FC Clear %(1)  
TDA Volt Threshold  
TDA Volt Time  
TDA Recovery  
FD Volt Threshold  
FD Volt Time  
98  
5000  
5
0 to 16000  
0 to 60  
2
1
2
2
1
2
mV  
s
0 to 16000  
0 to 16000  
0 to 60  
mV  
mV  
s
5500  
5000  
5
Integer  
FD Recovery  
0 to 16000  
mV  
5000  
(1) Setting to –1% prevents the TDA, TCA, FD, or FC flag from being set or cleared based on state of charge.  
11  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
1st LEVEL PROTECTION FEATURES  
The bq20z80 supports a wide range of battery and system protection features that are easily configured or  
disabled via the integrated data flash.  
Cell Overvoltage  
The bq20z80 can disable charging by turning off the charge FET if any cell voltage is DF:COV Threshold for  
a DF:COV Time. This feature is disabled if DF:COV Time = 0.  
During the time between when an excessive voltage is first detected and the expiration of DF:COV Time,  
SBS.SafetyAlert( ) [COV] is set. If, during this period, the voltage falls below the DF:COV Threshold, this flag is  
cleared.  
If DF:COV Time expires, the charge FET is turned off. The ZVCHG FET is also turned off if the DF:Operation  
Cfg A [ZVCHG1, ZVCHG0] bits are set appropriately. Also, when DF:COV Time expires, SBS.ChargingCurrent( )  
and SBS.ChargingVoltage(  
) are cleared, SBS.BatteryStatus( ) Terminate_Charge_Alarm is set, and  
SBS.SafetyStatus( ) [COV] is set.  
For the bq20z80 to fully recover from a cell overvoltage condition, all SBS.CellVoltagex( ) values must be the  
DF:COV Recovery threshold. When this occurs, the charge FET is allowed to be turned on only if other safety  
and configuration states permit. On recovery from an overvoltage condition, SBS.BatteryStatus(  
)
Terminate_Charge_Alarm is reset, SBS.ChargingCurrent( ) and SBS.ChargingVoltage( ) are set to the  
appropriate value per the charging algorithm, and SBS.SafetyStatus( ) [COV] is reset.  
However, when the bq20z80 has SBS.SafetyStatus( ) [COV] set, the charge FET is turned on again while  
SBS.Current( ) is reported to be (-) DF:Dsg Current Threshold. No other flags change state until full recovery  
is reached. This prevents overheating the charge-FET body diode during discharge from an overvoltage  
condition.  
SIZE  
(BYTES)  
DEFAULT  
VALUE  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
UNITS  
COV Threshold  
COV Recovery  
COV Time  
3700 to 5000  
0 to 4400  
0 to 60  
2
2
1
4300  
3900  
2
mV  
s
1st Level Safety / Voltage (0)  
Integer  
Cell Overvoltage Threshold Compensation  
If the bq20z80 detects charging (SBS.BatteryStatus( ) [DSG] = 0) the actual threshold for cell-overvoltage  
detection may be reduced, based on the reported SBS.Temperature( ).  
If SBS.Temperature( ) is > DF:Over Temp ChgDF:COV Temp Hys, the actual cell-overvoltage threshold used is  
DF:COV ThresholdDF:COV Delta. However, if DF:COV Delta = 0 then the compensation of the cell-overvoltage  
threshold is disabled.  
SIZE  
(BYTES)  
DEFAULT  
VALUE  
NAME  
DESCRIPTION  
FORMAT  
VALID RANGE  
UNITS  
Overtemp Chg  
COV Temp Hys  
COV Delta  
1st Level Safety / Temperature (2)  
0 to 1200  
0 to 250  
0 to 200  
2
1
1
550  
100  
20  
0.1°C  
Integer  
1st Level Safety / Voltage (0)  
mV  
Pack Overvoltage  
The bq20z80 can disable charging by turning off the charge FET if SBS.Voltage( ) is DF:POV Threshold for a  
period DF:POV Time. However, if DF:POV Time = 0, this feature is disabled.  
During the period between when an excessive voltage is detected and the expiration of DF:POV Time, the  
SBS.SafetyAlert( ) [POV] bit is set. If during this period, the voltage falls below the DF:POV Threshold, this flag is  
cleared.  
If DF:POV Time expires, the charge FET is turned off. The ZVCHG FET is also turned off if the DF:Operation Cfg  
A [ZVCHG1, ZVCHG0] bits are set appropriately. Also, when DF:POV Time expires, SBS.ChargingCurrent( ) and  
SBS.ChargingVoltage(  
)
are set to 0, SBS.BatteryStatus(  
)
Terminate_Charge_Alarm is set, and  
SBS.SafetyStatus( ) [POV] is set.  
12  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
For the bq20z80 to fully recover from a pack overvoltage condition, SBS.Voltage( ) must be DF:POV Recovery  
threshold. When this occurs, the charge FET is allowed to be turned on only if other safety and configuration  
states permit. On recovery from a pack overvoltage condition, SBS.BatteryStatus( ) Terminate_Charge_Alarm is  
reset, SBS.ChargingCurrent( ) and SBS.ChargingVoltage( ) are set to the appropriate value per the charging  
algorithm, and SBS.SafetyStatus( ) [POV] is reset.  
However, when the SBS.SafetyStatus( ) [POV] bit set, the charge FET is turned on again while SBS.Current( ) is  
reported to be (-) DF:Dsg Current Threshold. No other flags change state until the full recovery is reached.  
This prevents overheating the charge-FET body diode during discharge from an overvoltage condition.  
SIZE  
(BYTES)  
DEFAULT  
VALUE  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
UNITS  
POV Threshold  
POV Recovery  
POV Time  
0 to 18000  
0 to 17000  
0 to 60  
2
2
1
17500  
16000  
2
mV  
s
1st Level Safety / Voltage (0)  
Integer  
Cell Undervoltage  
The bq20z80 can disable discharging by turning off the discharge FET if any SBS.CellVoltagex( ) is DF:CUV  
Threshold for a period DF:CUV Time. This feature is disabled if DF:CUV Time = 0.  
During the period between the time when a low voltage is first detected and the expiration of DF:CUV Time, the  
SBS.SafetyAlert( ) [CUV] bit is set. If, during this period, the voltage rises above DF:CUV Threshold, this flag is  
cleared.  
If DF:CUV Time expires, the discharge FET is turned off and the ZVCHG FET is turned on if DF:Operation Cfg A  
[ZVCGH1, ZVCHG0] are set appropriately. Also, when DF:CUV Time expires, SBS.BatteryStatus( ) [TDA, FD]  
are set, SBS.ChargingCurrent( ) is set to DF:Pre-Charge Current, SBS.OperationStatus( ) [XDSG] is set and  
SBS.SafetyStatus( [CUV] is set.  
For the bq20z80 to fully recover from a cell undervoltage condition, all SBS.CellVoltagex( ) values should  
be DF:CUV Recovery threshold. When this occurs, the discharge FET is allowed to be turned on only if other  
safety and configuration states permit. On recovery from an undervoltage condition, SBS.BatteryStatus( ) [TDA]  
is reset, SBS.ChargingCurrent( ) and SBS.ChargingVoltage( ) are set to the appropriate value per the charging  
algorithm and SBS.OperationStatus( ) [XDSG] and SBS.SafetyStatus( ) [CUV] are reset.  
However, when the bq20z80 has the SBS.SafetyStatus( ) [CUV] bit set, the discharge FET is turned on again if  
SBS.Current( ) is reported to be DF:Chg Current Threshold. No other flags change state until full recovery is  
reached. This prevents overheating the discharge-FET body diode during charging from an undervoltage  
condition.  
SIZE  
(BYTES)  
DEFAULT  
VALUE  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
UNITS  
CUV Threshold  
CUV Recovery  
CUV Time  
0 to 3500  
0 to 3600  
0 to 60  
2
2
1
2200  
3000  
2
mV  
s
1st Level Safety / Voltage (0)  
Integer  
Pack Undervoltage  
The bq20z80 can disable discharging by turning off the discharge FET if SBS.Voltage( ) is DF:PUV Threshold  
for a time period DF:PUV Time. This feature is disabled if DF:PUV Time = 0.  
During the period between the time when a low voltage is first detected and the expiration of DF:PUV Time,  
SBS.SafetyAlert( ) [PUV] is set. If, during this period, the voltage rises above the DF:PUV Threshold, this flag is  
cleared.  
If DF:PUV Time expires, the discharge FET is turned off and the ZVCHG FET is turned on if DF:Operation Cfg A  
[ZVCHG1, ZVCHG0] are set appropriately. Also when DF:PUV Time expires SBS.BatteryStatus( ) [TDA,FD]are  
set, SBS.ChargingCurrent( ) is set to DF:Pre-Charge Current, SBS.OpertionStatus( ) [XDSG] is set and  
SBS.SafetyStatus( ) [PUV] is set.  
13  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
For the bq20z80 to fully recover from a pack undervoltage condition, SBS.Voltage( ) should be DF:PUV  
Recovery threshold. When this occurs, the discharge FET is allowed to be turned on only if other safety and  
configuration states permit. On recovery from a pack undervoltage condition, SBS.BatteryStatus( ) [TDA] is reset,  
SBS.ChargingCurrent( ) and SBS.ChargingVoltage( ) are set to the appropriate value per the charging algorithm  
and SBS.OperationStatus( ) [XDSG] and SBS.SafetyStatus( ) [PUV] are reset.  
However, when SBS.SafetyStatus( ) [PUV] is set, the discharge FET is turned on again, as long as  
SBS.Current( ) is reported to be DF:Chg Current Threshold. No other flags change state until full recovery is  
reached. This prevents overheating the discharge-FET body diode during charging from an undervoltage  
condition.  
SIZE  
(BYTES)  
DEFAULT  
VALUE  
NAME  
DESCRIPTION  
FORMAT  
VALID RANGE  
UNITS  
PUV Threshold  
PUV Recovery  
PUV TIme  
0 to 16000  
0 to 16000  
0 to 60  
2
2
1
11000  
12000  
2
mV  
s
1st Level Safety / Voltage (0)  
Integer  
Charge and Discharge Overcurrent  
The bq20z80 has two independent tiers (levels) of overcurrent protection for discharge and charge. These two  
tiers require the SBS.Current( ) to be a programmed threshold in either charge or discharge current for a  
period a programmable time. If the programmable time for any of the current-protection levels is set to 0, that  
specific feature is disabled.  
The bq29312A provides a third level of discharge overcurrent (overload) protection that reacts according to the  
bq29312A internal settings. The bq29312A discharge overcurrent is configured by the bq20z80, where DF:AFE  
OC Dsg (see bq29312A OLV register) and DF:AFE OC Dsg Time (see bq29312A OLT register) are used to  
provide the current threshold and delay timing. See the 'Overload Detection' section of the bq29312A data sheet  
for more details and the appropriate values to use.  
For the first two tiers of overcurrent protection, during the period between when excessive current is detected  
and the expiration of the timer, the respective SBS.SafetyAlert( ) bit is set. If the timer expires, or SBS.Current( )  
returns within normal operating parameters, the SBS.SafetyAlert( ) bit is cleared.  
SBS.SAFETYALERT( ),  
SBS.SAFETYSTATUS( )  
AND DF:Nonremovable Cfg  
DF CLEAR  
THRESHOLD  
DF THRESHOLD  
DF TIME  
FET  
Tier-1  
Charge  
OC (1st Tier) Chg  
OC (2nd Tier) Chg  
OC (1st Tier) Dsg  
OC (2nd Tier) Dsg  
AFE OC Dsg  
OC (1st Tier) Chg Time  
OC (2nd Tier) Chg Time  
OC (1st Tier) Dsg Time  
OC (2nd Tier) Dsg Time  
AFE OC Dsg Time  
CHG  
CHG  
DSG  
DSG  
OCC  
OCC2  
OCD  
OC Chg Recovery  
Tier-2  
Charge  
Tier-1  
Discharge  
OC Dsg Recovery  
Tier-2  
Discharge  
OCD2  
AOCD(1)  
Tier-3  
Discharge  
CHG,  
DSG  
AFE OC DsgRecovery  
(1) No SBS.SafetyAlert( ) flag  
If the timer of any tier expires during charging, the charge FET is turned off and the ZVCHG FET is turned off if  
the DF:Operation Cfg A [ZVCHG1, ZVCHG0] are set appropriately. When this occurs, the internal  
AFE_Current_Fault timer is started from 0, SBS.ChargingCurrent( ) and SBS.ChargingVoltage( ) are set to 0,  
SBS.BatteryStatus( ) [TCA] is set, and the appropriate tier flag is set in SBS.SafetyStatus( ).  
However, when the bq20z80 has either of SBS.SafetyStatus( ) [OCC, OCC2] set, the charge FET is turned on  
again, as long as SBS.Current( ) is reported to be (-) DF:Dsg Current Threshold. No other flags change state  
until full recovery is reached. This prevents overheating the charge-FET body diode during discharge. This action  
is not affected by the state of DF:Operation Cfg B [NR].  
14  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
If the timer of either of the first two tiers expires during discharging, the discharge FET is turned off and the  
ZVCHG FET is turned on if DF:Operation Cfg A [ZVCHG1, ZVCHG0] are set appropriately. When this occurs the  
AFE_Current_Fault timer is started from 0, SBS.ChargingCurrent( ) is set to DF:Pre-Charge Current,  
SBS.OperationStatus( ) [XDSG] is set, SBS.BatteryStatus( ) [TDA] is set, and the correct tier flag is set in  
SBS.SafetyStatus( ).  
When the bq29312A detects a discharge-overcurrent fault, the charge and discharge FETs are turned off, the  
XALERT pin of the bq20z80 is driven low by the XALERT pin of the bq29312, and the bq29312A is interrogated.  
When the bq20z80 identifies the overcurrent condition, the AFE_Current_Fault timer is started from 0,  
SBS.BatteryStatus( ) [TDA] is set, SBS.ChargingCurrent( ) is set to 0, and SBS.SafetyStatus( ) [AOCD] is set.  
However, when the bq20z80 has any of SBS.SafetyStatus( ) [OCD, OCD2, AOCD] set, the FETs are turned on  
again, as long as SBS.Current( ) is reported to be (-) DF:Dsg Current Threshold. No other flags change state  
until full recovery is reached. This prevents overheating the charge-FET body diode during discharge. This action  
is not affected by the state of DF:Operation Cfg B [NR].  
The bq20z80 can individually configure each overcurrent-protection feature to recover via two different methods  
based on DF:Operation Cfg B [NR].  
Standard Recovery, where DF:Operation Cfg B [NR] = 0, and the overcurrent tier is not selected in  
DF:Non-Removable Cfg. When the pack is removed and reinserted the condition is cleared. Pack removal and  
reinsertion is detected by a low-to-high-to-low transition on the PRES input. When the tier is not selected in  
DF:Non-Removable Cfg, that particular feature uses the Non-Removable Battery Mode recovery.  
Nonremovable Battery Mode Recovery where DF:Operation Cfg B [NR] = 1. The state of DF:Non-Removable  
Cfg has no consequence when DF:Operation Cfg B [NR] = 1. This recovery requires SBS.AverageCurrent( ) to  
be the respective recovery threshold, and for the AFE_Current_Fault timer DF:Current Recovery Time.  
When a charging-fault recovery condition is detected, then the charge FET is allowed to be turned on, if other  
safety and configuration states permit, the ZVCHG FET is turned off if DF:Operation Cfg A [ZVCHG1, ZVCHG0]  
are set appropriately, SBS.BatteryStatus( ) [TCA] is reset, SBS.ChargingCurrent( ) and SBS.ChargingVoltage( )  
are set to the appropriate value per the charging algorithm, and the appropriate SBS.SafetyStatus( ) flag is reset.  
When a discharging-fault recovery condition is detected, the discharge FET is allowed to be turned on if other  
safety and configuration states permit the ZVCHG FET is turned off if DF:Operation Cfg A [ZVCHG1, ZVCHG0]  
are set appropriately, SBS.BatteryStatus( ) [TDA] is reset, SBS.ChargingCurrent( ) and SBS.ChargingVoltage( )  
are set to the appropriate value per the charging algorithm and the SBS.OperationStatus( ) [XDSG] and the  
appropriate SBS.SafetyStatus( ) flags are reset.  
VALID  
RANGE  
SIZE  
(BYTES)  
DEFAULT  
VALUE  
NAME  
CLASS / SUBCLASS  
FORMAT  
UNITS  
OC (1st Tier) Chg  
OC Chg Recovery  
0 to 20000  
0 to 1000  
0 to 60  
2
2
1
1
2
2
1
2
1
2
1
1
2
1
6000  
200  
2
mA  
OC (1st Tier) Chg Time  
Current Recovery Time  
OC (1st Tier) Dsg  
s
s
0 to 60  
8
0 to 20000  
0 to 1000  
0 to 60  
mA  
mA  
s
6000  
200  
5
OC Dsg Recovery  
Integer  
OC (1st Tier) Dsg Time  
OC (2nd Tier) Chg  
OC (2nd Tier) Chg Time  
OC (2nd Tier) Dsg  
1st Level Protection / Current (1)  
0 to 20000  
0 to 60  
mA  
s
8000  
2
0 to 20000  
0 to 60  
mA  
s
6000  
2
OC (2nd Tier) Dsg Time  
AFE OC Dsg  
Hex  
Integer  
Hex  
00 to 1f  
N/A  
mA  
N/A  
0x12  
100  
0x0f  
AFE OC Dsg Recovery  
AFE OC Dsg Time  
10 to 1000  
00 to 0f  
15  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
Short-Circuit Protection  
The bq20z80 short-circuit protection is controlled by the bq29312A, but is recovered by the bq20z80. This allows  
different recovery methods to accommodate various applications.  
The bq29312A charge short-circuit and discharge short-circuit protection are configured by the bq20z80 in  
DF:AFE SC Chg Cfg (see bq29312A SCC register) and DF:AFE SC Dsg Cfg (see bq29312A SCD register),  
respectively. See the 'Short-circuit Detection' section of the bq29312A data sheet for more details and the  
appropriate values to use.  
SBS.SAFETYSTATUS( )  
AND DF:Nonremovable Cfg  
Short Circuit  
DF NAME  
FET  
DF CLEAR THRESHOLD  
Charge  
AFE SC Chg Cfg  
AFE SC Dsg Cfg  
CHG  
DSG  
ASCC  
ASCD  
AFE SC Recovery  
Discharge  
When the bq29312A detects a short circuit in charge or short circuit in discharge fault, the charge and discharge  
FETs are turned off, the XALERT pin of the bq20z80 is driven low by the XALERT pin of the bq29312A and the  
bq29312A is interrogated. When the bq20z80 identifies the short-circuit condition (charge or discharge current  
direction), the internalAFE_Current_Fault timer is started from 0, either of SBS.BatteryStatus( ) [TCA, TDA] are  
set, SBS.ChargingCurrent( ) and SBS.ChargingVoltage( ) is set to 0, and SBS.SafetyStatus( ) [ASCC, ASCD] is  
set. If the short-circuit condition is in discharge, then SBS.OperationStatus( ) [XDSG] is also set.  
However, when the bq20z80 has SBS.SafetyStatus( ) [ASCC[ set, the CHG FET is turned on again, as long as  
SBS.Current( ) is reported to DF:Dsg Current Threshold. Also, when the bq20z80 has SBS.SafetyStatus( )  
[SCD[ set, the DSG FET is turned on again, as long as SBS.Current( ) is reported to be DF:Chg Current  
Threshold. No other flags change state until full recovery is reached. This prevents overheating of charge- or  
discharge-FET body diode during operation. This action is not affected by the state of DF:Operation Cfg B [NR].  
Each bq20z80 short-circuit protection feature can be individually configured to recover via two different methods,  
based on DF:Operation Cfg B [NR].  
Standard Recovery is where DF:Operation Cfg B [NR] = 0 and the overcurrent tier is not selected in  
DF:Non-Removable Cfg. When the pack is removed and re-inserted, the condition is cleared. Pack removal and  
re-insertion is detected by transition on the PRES input from low to high to low. When the tier is not selected in  
DF:Non-Removable Cfg, that particular feature uses the Nonremovable Battery Mode recovery.  
Nonremovable Battery Mode Recovery is where DF:Operation Cfg  
B [NR] = 1. The state of  
DF:Non-Removable Cfg has no consequence when DF:Operation Cfg B [NR] = 1. This recovery requires  
SBS.AverageCurrent( ) to be DF:AFE SC Recovery threshold and for the internal AFE_Current_Fault timer to  
be DF:Current Recovery Time.  
When the recovery condition for a charging fault is detected, the charge FET is allowed to be turned on if other  
safety and configuration states permit. The ZVCHG FET is turned off if DF:Operation Cfg A [ZVCHG1, ZVCHG0]  
are set appropriately. When this occurs, SBS.BatteryStatus( ) [TCA] is reset, SBS.ChargingCurrent( ) and  
SBS.ChargingVoltage( ) are set to the appropriate values per the charging algorithm, and the appropriate  
SBS.SafetyStatus( ) flag is reset.  
When the recovery condition for a discharging fault is detected, the discharge FET is allowed to be turned on if  
other safety and configuration states permit. The ZVCHG FET is turned off if DF:Operation Cfg A [ZVCHG1,  
ZVCGH0] are set appropriately. When this occurs SBS.BatteryStatus( ) [TDA] is reset, SBS.ChargingCurrent( )  
and SBS.ChargingVoltage(  
)
are set to the appropriate value per the charging algorithm, and  
SBS.OperationStatus( ) [XDSG] and the appropriate SBS.SafetyStatus( ) flags are reset.  
VALID  
RANGE  
SIZE  
(BYTES)  
DEFAULT  
VALUE  
NAME  
CLASS / SUBCLASS  
FORMAT  
UNITS  
Low Nibble = AFE SC Chg  
High Nibble = AFE SC Chg Time  
Low Nibble = AFE SC Dsg  
High Nibble = AFE SC Dsg Time  
Integer  
AFE SC Chg Cfg  
0x77  
0x00 to  
0xff  
Hex  
1
2
N/A  
mA  
1st Level Safety /  
Current (1)  
AFE SC Dsg Cfg  
AFE SC Recovery  
0x77  
1
0 to 200  
16  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
Overtemperature Protection  
The bq20z80 has overtemperature protection for both charge and discharge conditions. In either case, if  
SBS.Temperature( ) is the protection threshold for a period the protection delay time, then action is taken.  
However, if the delay time is set to 0, then the feature is disabled.  
SBS.SAFETYALERT( )  
SBS.SAFETYSTATUS( )  
DF CLEAR  
THRESHOLD  
DF THRESHOLD  
DF TIME  
FET  
Charge  
Over Temp Chg  
Over Temp Chg  
OT Chg Time  
OT Dsg Time  
CHG  
DSG  
OTC  
OTD  
OT Chg Recovery  
OT Dsg Recovery  
Discharge  
During the period between detection of excessive temperature and the expiration of the timer, the respective  
SBS.SafetyAlert( ) bit is set. If the timer expires or SBS.Temperature( ) returns within the normal operation range,  
the SBS.SafetyAlert( ) bit is cleared.  
If SBS.SafetyStatus( ) [OTC] becomes set and if DF:Operation Cfg B [OTFET] is set, the CHG FET is turned off  
and the ZVCHG FET turned off, if DF:Operation Cfg A [ZVCHG1, ZVCHG0] are set appropriately. If  
SBS.SafetyStatus( ) [OTD] becomes set and if DF:Operation Cfg B [OTFET] is set, the DSG FET turns off. If the  
DF:Operation Cfg B [OTFET] bit is cleared, no FET action is taken. Also, SBS.BatteryStatus( ) [OTA] is set,  
SBS.ChargingCurrent( ) and SBS.ChargingVoltage( ) are set to 0, either of SBS.BatteryStatus( ) [TCA, TDA] is  
set, and the corresponding flag in SBS.SafetyStatus( ) is set. If SBS.SafetyStatus( ) [OTD] is set AND  
DF:Operation Cfg B [OTFET] is set then SBS.OperationStatus( ) [XDSG] is set.  
However, when SBS.SafetyStatus( ) [OTC] is set, the CHG FET is turned on again, as long as SBS.Current( ) is  
reported to be (-) DF:Dsg Current Threshold. Also, when the bq20z80 has SBS.SafetyStatus( ) [OTD] set, the  
DSG FET is turned on again, as long as SBS.Current( ) is reported to be DF:Chg Current Threshold. No other  
flags change state until full recovery is reached. This prevents overheating the respective FET's body diode  
during operation. This action is not affected by the state of DF:Operation Cfg B [NR].  
For normal recovery to be achieved, SBS.Temperature( ) must be the respective DF:OT Chg Recovery or  
DF:OT Dsg Recovery. When this occurs, the FETs are returned to the normal operating state if applicable,  
SBS.BatteryStatus(  
)
[OTA] is cleared, either of SBS.BatteryStatus(  
)
[TCA, TDA] is cleared,  
SBS.ChargingCurrent( ) and SBS.ChargingVoltage( ) are set to the appropriate values per the charging  
algorithm, and the appropriate SBS.SafetyStatus( ) flag is reset. If SBS.SafetyStatus( ) [OTD] is cleared, then  
SBS.OperationStatus( ) [XDSG] is cleared.  
VALID  
RANGE  
SIZE  
(BYTES)  
DEFAULT  
VALUE  
NAME  
CLASS / SUBCLASS  
FORMAT  
UNITS  
Over Temp Chg  
OT Chg Recovery  
OT Chg Time  
0 to 1200  
0 to 1200  
0 to 60  
2
2
1
2
1
2
0.1°C  
0.1°C  
s
550  
500  
2
1st Level Safety / Temperature (2)  
Integer  
Over Temp Dsg  
OT Dsg Time  
0 to 1200  
0 to 30  
0.1°C  
s
600  
2
OT Dsg Recovery  
0 to 1200  
0.1°C  
550  
AFE Watchdog  
The bq29312A incorporates a watchdog feature that automatically turns off the CHG, DSG, and ZVCHG FETs if  
the bq29312A does not receive the appropriate frequency input on the WDI pin. The bq20z80 has no warning  
that this is about to happen, but it can report the occurrence, once the bq20z80 is able to interrogate the  
bq29312A.  
When the XALERT input of the bq20z80 is triggered by the XALERT pin of the bq29312A, the bq20z80 reads  
AFE.STATUS. If AFE.STATUS [WDF] is set, then SBS.Safety Status( ) [WDF] is set, and periodic verification of  
the bq29312A RAM is undertaken. If verification of the bq29312A RAM fails then SBS.SafetyStatus( ) [WDF] is  
set and the FET?s will turn off. Verification of the bq29312A RAM will continue every second. If the periodic  
verification passes, then SBS.SafetyStatus( ) [WDF] is cleared and the FETs returned to normal operation. If  
DF:AFE Check Time = 0 then on detection of a verification fault the DF:PF Flags 1 [AFE_C] will NOT be set and  
PF mode will NOT be entered. If DF:AFE Check Time is not 0 then if DF:AFE Check Time attempts of the  
verification fail, the bq20z80 sets DF:PF Flags 1 [AFE_P] and enters permanent failure. See Periodic AFE  
Verification for further details.  
17  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
SIZE  
(BYTES)  
DEFAULT  
VALUE  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
UNITS  
AFE Check Time  
1st Level Safety / AFE Watchdog  
(3)  
0 to 255  
1
0
Integer  
Faults  
18  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
Host Watchdog  
The bq20z80 can be configured to require the host system to communicate with the battery periodically, else the  
battery disables charging and discharging. The Host Watchdog function is only active in Normal Power mode and  
is disabled if the timeout period is set to 0.  
If the bq20z80 does not receive any valid SMBus communications for a period of time DF:Host Watchdog  
Timeout, the FETs are turned off, SBS.ChargingVoltage( ) and SBS.ChargingCurrent( ) are cleared to 0,  
SBS.BatteryStatus( ) [TCA, TCA], SBS.OperationStatus( ) [XDSG], SBS.SafetyStatus( ) [HWDG] are set.  
For normal recovery to be achieved, normal SMBus communications must be resumed. When this occurs, the  
FETs are returned to the normal operating state, SBS.BatteryStatus(  
) [TCA, TDA] are cleared,  
SBS.ChargingCurrent( ) and SBS.ChargingVoltage( ) are set to the appropriate value per the charging algorithm  
and SBS.OperationStatus( ) [XDSG] and SBS.SafetyStatus( ) [HWDG] are reset.  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
SIZE (BYTES)  
UNITS  
DEFAULT VALUE  
Host Watchdog Timeout  
1st Level Safety / Host Comm (3)  
Integer  
0 to 255  
1
s
0
19  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
2nd LEVEL PROTECTION FEATURES  
The bq20z80 provides features that can be used to indicate a more serious fault via the SAFE and SAFE  
outputs. These outputs can be used to blow an in-line fuse to permanently disable the battery pack from charge  
or discharge activity.  
Actions on Detection of 2nd Level (Permanent) Failure  
When the bq20z80 SBS.PFStatus( ) changes from 0x00 to indicate a permanent failure then the following actions  
are taken in sequence.  
CHG, DSG, and ZVCHG FETs are turned OFF.  
SBS.BatteryStatus( ) [TCA, TDA] are set.  
A backup of SBS data is stored to data flash including SBS.Voltage( ), SBS.CellVoltage1( ),  
SBS.CellVoltage2( ), SBS.CellVoltage3( ), SBS.CellVoltage4( ), SBS.Current( ), SBS.Temperature( ),  
SBS.BatteryStatus( ), SBS.RemaingCapacity( ) , SBS.SafetyStatus( ), SBS.ChargingStatus( ), AFE.Data  
(complete memory map).  
Data Flash write access is then disabled, but the data flash can be read.  
SBS.ChargingCurrent( ) and SBS.ChargingVoltage( ) are set to 0.  
The appropriate bit in DF:PF Flag 1 is set.  
If the appropriate bit in DF:Permanent Fail Cfg is set, then 0x3672 is programmed to DF:Fuse Flag, the  
SAFE pin is driven and latched low, and the SAFE pin is driven and latched high.  
SBS.SafetyStatus( ) [PF] is set.  
SIZE  
(BYTES)  
DEFAULT  
VALUE  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
UNITS  
PF Flags 1  
Fuse Flag  
0x0000 to 0xffff  
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
1
1
1
1
1
1
1
1
1
N/A  
N/A  
mV  
0x0000  
0x0000  
0
Hex  
0x0000 or 0x3672  
PF Voltage  
PF C1 Voltage  
PF C2 Voltage  
PF C3 Voltage  
PF C4 Voltage  
PF Current  
mV  
0
0 to 65535  
mV  
0
Integer  
mV  
0
mV  
0
2nd Level Safety / Device  
Status Data (96)  
–32768 to 32767  
–9999 to 9999  
0x0000 to 0xffff  
mA  
0
PF Temperature  
PF Batt Stat  
PF RC-mAh  
PF RC-10mWh  
PF Chg Status  
PF Safety Status  
PF Flags 2  
0.1°C  
N/A  
mAh  
10mWh  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
0
Hex  
0x0000  
0
Integer  
0 to 65535  
0
0x0000 to 0xffff  
0x0000  
0x0000  
0x0000  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
Hex  
AFE Status  
0x00 to 0xff  
0x00 to 0xff  
0x00 to 0xff  
0x00 to 0xff  
0x00 to 0xff  
0x00 to 0xff  
0x00 to 0xff  
0x00 to 0xff  
0x00 to 0xff  
AFE Output  
AFE State  
AFE Function  
AFE Cell Select  
AFE OLV  
2nd Level Safety / AFE Regs  
(97)  
Hex  
AFE OLT  
AFE SCC  
AFE SCD  
20  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
Permanent Failure Flags  
When any NEW cause of PF is detected in SBS.PFStatus( ), the NEW cause is added to DF:PF Flag 1. This  
allows DF:PF Flag 1 to show ALL of the different permanent failure conditions that have occurred.  
On the first occasion of SBS.PFStatus( ) changing from 0x00 the value is stored to DF:PF Flag 2.  
Clearing Permanent Failure  
The bq20z80 permanent failure mode can be cleared by sending two SBS.ManufacturerAccess( ) commands in  
sequence. See SBS.ManufacturerAccess( ) for more details.  
Safety Overvoltage Protection  
The bq20z80 reports a safety-overvoltage condition when SBS.Voltage( ) is the DF:SOV Threshold for a period  
DF:SOV Time. During the time between when the excessive voltage is first detected and the expiration of  
DF:SOV TimeSBS.PFAlert( ) [SOV] is set.  
If DF:Permanent Fail Cfg [XSOV] is set, the SAFE pin is driven low and the SAFE pin is driven high. If DF:SOV  
Time is set to 0, this feature is disabled.  
SIZE  
(BYTES)  
DEFAULT  
VALUE  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
UNITS  
SOV Threshold  
SOV Time  
0 to 20000  
0 to 30  
2
1
mV  
s
18000  
2nd Level Safety / Voltage (16)  
Integer  
0 (4 typical)  
Cell Imbalance Fault Protection  
The bq20z80 reports a cell imbalance condition when SBS.Current( ) is DF:Cell Imbalance Current for a  
period of DF:Battery Rest Time, AND the difference between the highest measured cell voltage  
(SBS.CellVoltagex( )MAX) and lowest measured cell voltage (SBS.CellVoltagex( )MIN) is DF:Cell Imbalance  
Fail Voltage for a period DF:Cell Imbalance Time.  
During the time between when excessive cell-voltage variance is first detected and the expiration of DF:Cell  
Imbalance Time, SBS.PFAlert( ) [CIM] is set.  
If DF:Permanent Fail Cfg [XCIM] is set, the SAFE pin is driven low and the SAFE pin is driven high. If DF:Cell  
Imbalance Time is set to 0, this feature is disabled.  
CLASS /  
SUBCLASS  
SIZE (BYTES)  
NAME  
FORMAT  
VALID RANGE  
UNITS  
DEFAULT VALUE  
Cell Imbalance Fail Voltage  
Cell Imbalance Time  
Cell Imbalance Current  
Battery Rest Time  
0 to 5000  
0 to 30  
2
1
1
1
mV  
s
1000  
0 (4 typical)  
2nd Level Safety/  
Voltage (16)  
Integer  
0 to 200  
0 to 240  
mA  
s
5
60  
2nd Level Protection IC Input  
The PFIN input of the bq20z80 can be used to determine the state of an external protection device such as the  
bq29400. If this pin is logic low for a period of time DF:PFIN Detect Time, the Permanent Failure Mode is  
entered. During the time between when PFIN is detected low and the expiration of DF:PFIN Detect  
TimeSBS.PFAlert( ) [PFIN] is set.  
If DF:Permanent Fail Cfg [XPFIN] is set, the SAFE pin is driven low and the SAFE pin is driven high. Also, if  
DF:PFIN Detect Time is set to 0, this feature is disabled.  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE SIZE (BYTES)  
0 to 30  
UNITS  
DEFAULT VALUE  
PFIN Detect Time  
2nd Level Safety / Voltage (16)  
Integer  
1
s
0 (4 typical)  
21  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
Safety Overcurrent Protection  
The bq20z80 reports a safety-overcurrent condition for either charge (SBS.Current( ) = positive) or discharge  
(SBS.Current( ) = negative). A fault is reported when SBS.Current( ) is the DF:SOC Chg or DF:SOC Dsg  
threshold for a period DF:SOC Chg Time or the DF:SOC Dsg Time. During the period between the time  
when excessive current, in charge, is first detected and the expiration of DF:SOC Chg Time, SBS.PFAlert( )  
[SOCC] is set. Between the time when excessive current, in discharge, is first detected and the expiration of  
DF:SOC Dsg TimeSBS.PFAlert( ) [SOCC] is set.  
The protection in discharge or charge can be independently configured or disabled. If either DF:Permanent Fail  
Cfg [XSOCC, XSOCD] are set, the SAFE pin is driven low and the SAFE pin is driven high. Also, if DF:SOC Chg  
Time or DF:SOC Dsg Time are set to 0, this feature is disabled for the respective current direction.  
SIZE  
(BYTES)  
DEFAULT  
VALUE  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
UNITS  
SOC Chg  
SOC Dsg  
0 to 30000  
0 to 30000  
0 to 30  
10000  
10000  
2
mA  
2nd Level Safety / Current (17)  
Integer  
SOC Chg Time  
SOC Dsg Time  
1
1
s
s
0 (4 typical)  
0 (4 typical)  
0 to 30  
Safety Overtemperature Protection  
The bq20z80 reports a safety overtemperature condition for either charge (SBS.Current( ) = positive) or  
discharge (SBS.Current( ) = negative). A fault is reported when SBS.Temperature( ) DF:SOT Chg or DF:SOT  
Dsg threshold for a period DF:SOT Chg Time or DF:SOT Dsg Time. During the period between the time when  
excessive temperature, in charge, is first detected and the expiration of DF:SOT Chg Time, SBS.PFAlert( )  
[SOTC] is set. Between the time when excessive temperature, in discharge, is first detected and the expiration of  
DF:SOT Dsg Time, SBS.PFAlert( ) [SOTD] is set.  
Either discharge or charge protection can be independently configured or disabled. If either DF:Permanent Fail  
Cfg [XSOTC, XSOTD] is set, the SAFE pin is driven low and the SAFE pin is driven high. If DF:SOT Chg Time or  
DF:SOT Dsg Time is set to 0, this feature is disabled for the respective current direction.  
SIZE  
(BYTES)  
DEFAULT  
VALUE  
NAME  
DESCRIPTION  
FORMAT  
VALID RANGE  
UNITS  
SOT Chg  
SOT Chg Time  
SOT Dsg  
0 to 1200  
0 to 30  
2
1
2
1
0.1°C  
650  
s
0.1°C  
s
0 (4 typical)  
750  
2nd Level Safety / Temperature (18)  
Integer  
0 to 1200  
0 to 30  
SOT Dsg Time  
0 (4 typical)  
The bq20z80 reports an open thermistor condition when SBS.Temperature( ) DF:Open Thermistor for a time  
DF:Open Time .  
Between the time when excessive temperature is first detected and the expiration of DF:Open Time,  
SBS.PFAlert( ) [OTS] is set. When DF:Open Time expires or is cleared then SBS.PFAlert( ) [OTS] is cleared  
If DF:Permanent Fail Cfg [XOTS] is set, the SAFE pin is driven low and the SAFE pin is driven high. If DF:Open  
Time is set to 0, this feature is disabled.  
VALID  
RANGE  
SIZE  
(BYTES)  
DEFAULT  
VALUE  
NAME  
CLASS / SUBCLASS  
FORMAT  
UNITS  
Open Thermistor  
Open Time  
-1000 to 1200  
0 to 30  
2
1
0.1°C  
–333  
2nd Level Safety /  
Temperature (18)  
Signed Int  
s
0 (4 typical)  
22  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
Charge and Zero-Volt Charge FET Fault Protection  
If the bq20z80 has at any time attempted to turn off the CHG or ZVCHG FETs, or AFE.OUTPUT [CHG] is set,  
and a level of charge SBS.Current( ) continues to flow that is DF:FET Fail Limit for a period of DF:FET Fail  
Time, then a CHG FET fault is reported.  
When the first occurrence of excessive level of charge SBS.Current( ) is detected, SBS.PFAlert( ) [CFETF] is set,  
and the bq20z80 attempts to turn off the CHG and ZVCHG FET again. SBS.PFAlert( ) [CFETF] is cleared if at  
any time before the expiration of DF:FET Fail Time, the current is measured below the DF:FET Fail Limit  
threshold.  
If DF:Permanent Fail Cfg [XCFETF] is set, the SAFE pin is driven low and the SAFE pin is driven high. If DF:FET  
Fail Time is set to 0, this feature is disabled.  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
0 to 500  
SIZE (BYTES)  
UNITS  
mA  
DEFAULT VALUE  
20  
FET Fail Limit  
FET Fail Time  
2
1
2nd Level Safety /  
FET Verification (18)  
Integer  
0 to 30  
s
0 (2 typical)  
Discharge FET Fault Protection  
If the bq20z80 has at any time attempted to turn off the DSG FET, or AFE.OUTPUT [DSG] is set, and a level of  
discharge SBS.Current( ) continues to flow (-) DF:FET Fail Limit for a period of DF:FET Fail Time, then a  
DSG FET fault is reported. If DF:FET Fail Time is set to 0, the feature is completely disabled.  
When the first occurrence of excessive level of discharge SBS.Current( ) is detected, SBS.PFAlert( ) [DFETF] is  
set, and the bq20z80 attempts to turn off the DSG FET again. SBS.PFAlert( ) [DFETF] is cleared if at any time  
before the DF:FET Fail Time times out, the current is measured below the (-) DF:FET Fail Limit threshold.  
If DF:Permanent Fail Cfg [XDFETF] is set, the SAFE pin is driven low and the SAFE pin is driven high. If DF:FET  
Fail Time is set to 0, this feature is disabled.  
AFE Communication Fault Protection (AFE_C)  
The bq20z80 continuously validates its read and write communications with the bq29312A. If either a read or  
write verify fails, an internal AFE_Fail_Counter is incremented. If the AFE_Fail_Counter > DF:AFE Fail Limit, the  
bq20z80 reports a permanent failure. If the DF:AFE Fail Limit is set to 0, this feature is not disabled, but reports a  
permanent failure after only one AFE communication fault. An AFE_C fault could also be declared if after a full  
reset the initial offset values read from the AFE cannot be verified. These values are A-to-D readings of the  
bq29312A VCELL output. The bq29312A offset values are verified by reading the values twice and confirming  
that the readings are within acceptable limits. If the offset value verification fails an AFE_C fault is declared.  
The internal AFE_Fail_Counter is decremented by one count each DF:AFE Fail Recovery Time.  
If DF:Permanent Fail Cfg [XAFE_C] is set, the SAFE pin is driven low and the SAFE pin is driven high.  
SIZE  
(BYTES)  
NAME  
CLASS / SUBCLASS FORMAT  
VALID RANGE  
UNITS  
DEFAULT VALUE  
AFE Fail Limit  
2nd Level Safety /  
AFE Verification (20)  
0 to 255  
0 to 255  
1
1
counts  
s
10  
20  
Integer  
AFE Fail Recovery Time  
23  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
Periodic AFE Verification  
The bq20z80 periodically (DF:AFE Check Time) compares the entire RAM in the bq29312A with that of the  
bq20z80 data flash and the expected control-bit states. If an error is detected, the internal AFE_Fail_Counter is  
incremented. If the internal AFE_Fail_Counter reaches the DF:AFE Fail Limit, the bq20z80 reports a permanent  
failure and SBS.PFStatus( ) [AFE_P] is set.  
The internal AFE_Fail_Counter is decremented by one count each DF:AFE Fail Recovery Time.  
However, if DF:Permanent Fail Cfg [XAFE_P] is set, the SAFE pin is driven low and the SAFE pin is driven high,  
and if DF:AFE Check Time is set to 0, this feature is disabled.  
SIZE  
(BYTES)  
DEFAULT  
VALUE  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
UNITS  
AFE Check Time  
2nd Level Safety / AFE Verification (20)  
Integer  
0 to 255  
1
s
0 (10 typical)  
Data Flash Failure  
The bq20z80 can detect if the data flash is not operating correctly. DF:PF Flags 1 [DFF] is set when either (i))  
After a full reset the instruction flash checksum does not verify, (ii) if any data flash write does not verify or (iii) if  
any data flash erase does not verify.  
If DF:Permanent Fail Cfg [XDFF] is set, the SAFE pin is driven low and the SAFE pin is driven high when DF:PF  
Flags 1 [DFF] becomes set.  
Fuse State Detection  
The bq20z80 can detect if an attempt has been made to blow the fuse, but this has failed. If the bq20z80 DF:PF  
Flag 1 is set and SBS.Current( ) is DF:Fuse Fail Limit in either charge or discharge directions for a period ≥  
the DF:Fuse Fail Time, SBS.PFStatus( ) [FBF] is set.  
When the DF:Fuse Fail Time timer begins, SBS.PFAlert( ) [FBF] is set. When the DF:Fuse Fail Time timer  
expires or is cleared, SBS.PFAlert( ) [FBF] is cleared.  
SIZE  
(BYTES)  
DEFAULT  
VALUE  
LABEL  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
UNITS  
Fuse Fail Time  
Fuse Fail Limit  
0 to 30  
0 to 20  
1
1
s
0 (10 typical)  
2
2nd Level Safety /  
Fuse Verification (21)  
Integer  
mA  
24  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
COMMUNICATIONS  
The bq20z80 uses SMBus v1.1 with Master Mode and package error checking (PEC) options per the SBS  
specification.  
SMBus On and Off State  
The bq20z80 detects an SMBus off state when SMBC and SMBD are logic-low for 2 seconds. Clearing this  
state requires either SMBC or SMBD to transition high. Within 1 ms, the communication bus is available.  
Packet Error Checking  
The bq20z80 can receive or transmit data with or without PEC.  
In the read-word protocol, the bq20z80 receives the PEC after the last byte of data from the host. If the host  
does not support PEC, the last byte of data is followed by a stop condition. After receipt of the PEC, the bq20z80  
compares the value to its calculation. If the PEC is correct, the bq20z80 responds with an ACKNOWLEDGE. If it  
is not correct, the bq20z80 responds with a NOT ACKNOWLEDGE and sets an error code.  
In the write-word and block-read in master mode, the host generates an ACKNOWLEDGE after the last byte of  
data sent by the bq20z80. The bq20z80 then sends the PEC, and the host, acting as a master-receiver,  
generates a NOT ACKNOWLEDGE and a stop condition.  
Gas Gauge  
Figure 1. SMBus Communication Protocol Without PEC  
25  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
Gas Gauge  
Figure 2. SMBus Communication Protocol With PEC  
PEC Calculation  
PEC calculation is an 8-bit cyclic redundancy check (CRC-8) based on the polynomial C(X) = X8 + X2 + X1 + 1  
All bytes in the transmission are used in the calculation, including: Address, Command, and Data.  
Not included: ACKNOWLEDGE, NOT ACKNOWLEDGE, start, stop, and repeated start.  
STANDARD SBS COMMANDS  
The bq20z80 SBS commands meet the SBD v1.1 specification.  
ManufacturerAccess( ) (0x00)  
This read- or write-word function provides battery-system level data, access to test controls, and security  
features.  
System Data (Returns Data)  
The commands in this section provide data to be read from 0x00 after the command has been written.  
Device Type: 0x0001, Returns IC part number. 0x0800 - The number is not stored in data flash, but is part of  
the instruction flash.  
Firmware Version: 0x0002, Returns the firmware version. This is not stored in data flash, but is part of the  
instruction flash. Its format is most-significant byte (MSB)  
= Decimal integer, and the  
least-significant byte (LSB) = sub-decimal integer, e.g., 0x0120 = version 01.20.  
Hardware Version: 0x0003, Returns the hardware version stored in single byte of reserved data flash. E.G.:  
0xa2 = Version A2.  
26  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
DF Checksum: 0x0004, This function is only available when the bq20z80 is Unsealed (SBS.OperationStatus( )  
[SS] = 0). A write to this command forces the bq20z80 to generate a checksum of the full Data  
Flash (DF) array and writes it to DF: The generated checksum is then returned within 45 ms.  
NOTE:  
If another SMBus comamnd is received while the checksum is being generated, the  
DF Checksum is generated but the response may be time out (<25ms).  
Manufacturer Status: 0x0006, This function is compatible with the equivalent command in the bq2084, and is  
available while the bq20z80 is in normal operation.  
This 16-bit word reports the battery status and is formatted the same as the bq2084.  
ManufacturerStatus  
High Byte  
bit7  
FET1  
0
bit6  
FET0  
0
bit5  
PF1  
0
bit4  
PF0  
0
bit3  
STATE3  
0
bit2  
STATE2  
0
bit1  
STATE1  
1
bit0  
STATE0  
0
Low Byte  
FET1, FET0 Indicated the state of the charge and discharge FETs  
0,0  
0,1  
1,0  
1,1  
Both charge and discharge FETs are on.  
Charge FET is off, discharge FET is on.  
Both charge and discharge FETs are off.  
Charge FET is on, discharge FET is off.  
PF1, PF0  
Indicates permanent failure cause when permanent failure indicated by STATE3-STATE0  
0,0  
0,1  
1,0  
1,1  
Fuse is blown if enabled via DF:PF Config settings (default, ie: NOT CIM, SOV or xFETF).  
Cell imbalance failure  
Safety voltage failure  
FET failure  
STATE3, STATE2, STATE1, STATE0 Indicates battery state as defined in Table 2  
Table 2. STATE Code for Manufacture Status  
STATE  
STATE CODE (hex)  
CORRESPONDING FLAG  
SBS.OperationStatus( ) WAKE  
Wake Up  
0
3
7
5
Pre-Charge  
SBS.ChargingStatus( ) PCHG and NOT SBS.BatteryStatus( ) DSG  
SBS.ChargeStatus( ) MCHG and NOT SBS.BatteryStatus( ) DSG  
SBS.ChargingStatus( ) FCHG and NOT SBS.BatteryStatus( ) DSG  
Terminate Charge  
Normal Charge  
Normal Discharge  
SBS.ChargingStatus( ) XCHG and NOT SBS.OperationStatus( ) XDSG and  
NOT SBS.OperationStatus( ) XDSGI  
1
Depleted  
Depleted AC  
Overheat Discharge  
Overheat Charge  
e
[SBS.OperationStatus( ) XDSG or XDSGI] and SBS.BatteryStatus( ) DSG  
Battery Fail - Over Charge  
Battery Fail - Low Temperature  
Battery Fail - Charger Termination  
8
c
[SBS.ChargingStatus( ) OCHGI or OCHGV or PCMTO or FCMTO or OC or  
XCHGLV] and NOT SBS.BatteryStatus( ) DSG  
Battery Fail  
SBS.SafetyStatus( ) SCC, AOCD or SCD and NOT Over- Heat - Charge and  
NOT Over Heat - Discharge and NOT Battery Fail - Charge and NOT  
Battery Fail -Discharge  
27  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
Table 2. STATE Code for Manufacture Status (continued)  
STATE  
Battery Fail - Charge  
Battery Fail - Discharge  
Over Heat - Charge  
Over Heat - Discharge  
Removed  
STATE CODE (hex)  
CORRESPONDING FLAG  
SBS.SafetyStatus( ) OCC or OCC2  
a
b
SBS.SafetyStatus( ) OCD or OCD2  
SBS.SafetyStatus( ) OTC  
SBS.SafetyStatus( ) OTD  
f
NOT SBS.OperationStatus( ) PRES  
Communication causes exit of sleep  
SBS.SafetyStatus( ) PF  
Sleep  
d
9
Permanent Failure  
System Control (Triggers Actions)  
The commands in this section cause the bq20z80 to take actions when written. No data is returned.  
Shutdown Command: 0x0010 Instructs the bq20z80 to verify and enter Shutdown. This commenad is only  
available whent he bq20z80 is in unsealed security mode (SBS.OperationStatus( ) [SS] = 0). See Shutdown in  
Power Modes.  
Sleep Command: 0x0011 Instructs the bq20z80 to enter Sleep. This commenad is only available whent he  
bq20z80 is in unsealed security mode (SBS.OperationStatus( ) [SS] = 0). See Sleep in Power Modes.  
IT Enable: 0x0021 A write forces the bq20z80 to begin the Impedance Track™ algorithm and sets DF:Update  
Status [ITEN]. This also sets SBS.OperationStatus( ) [VOK, QEN]. VOK indicates that voltages are OK for a  
QMAX update for the Impedance Track™ algorithm. QEN indicates QMAX update is in progress. This function is  
only available when the bq20z80 is Unsealed.  
DF:Update Status  
bit7  
bit6  
bit5  
bit4  
bit3  
bit2  
bit1  
bit0  
Low Byte  
RSVD  
RSVD  
RSVD  
RSVD  
RSVD  
ITEN  
RSVD  
RSVD  
RSVD (bit 0, 1, 3, 4, 5, 6, 7) Reserved and should be 0  
ITEN (bit 2) 1 = Impedance Track™ algorithm and Lifetime data updating enabled  
SIZE  
(BYTES)  
DEFAULT  
VALUE  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
UNITS  
N/A  
Update Status  
Gas Gauging / State (82)  
Hex  
0x00 or 0x04  
1
0x00  
Permanent Fail Clear: (1) 0x2673 then (2) 0x1712, Instructs the bq20z80 to clear the Permanent Failure  
Status, clear the Permanent Failure Flag, clear the SAFE and SAFE pins, and unlock the data flash for writes.  
This function is only available when the bq20z80 is Unsealed  
NOTE:  
(1) must be followed by (2). If the clear fails then (1) can only be re-sent after 4  
seconds since the last communication in the failed attempt. If communication other  
than the second code occurs after the first code is sent, the clear fails.  
SAFE Activation: 0x0030 Drives the SAFE pin low and the SAFE pin high. This function is only available when  
the bq20z80 is Unsealed.  
SAFE Clear: 0x0031 Drives the SAFE pin high and the SAFE pin low, only if protection functions allow. This  
does not clear PF Mode. This function is only available when the bq20z80 is Unsealed.  
LEDs ON: 0x0032 Activates all configured LEDs to stay on. This function is only available when the bq20z80 is  
Unsealed.  
LEDs OFF: 0x0033 Deactivates all configured LEDs. This function is only available when the bq20z80 is  
Unsealed.  
Display ON: 0x0034 Activates the configured LED display per the level of SBS.RemainingStateOfCharge( ). The  
display turns off per the normal display configuration. This function is only available when the bq20z80 is  
Unsealed.  
28  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
Calibration Mode: 0x0040 Places the bq20z80 into calibration mode. See Calibrating the bq20z80 application  
note for further details. This function is only available when the bq20z80 is Unsealed.  
bq20z80 Reset: 0x00041 When written to the bq20z80 undergoes a full reset. The bq20z80 clocks stretch  
during the few milli-seconds taken to complete the reset. This function is only available when the bq20z80 is  
Unsealed.  
Security (Enables and Disables Features)  
There are three levels of secured operation within the bq20z80. To switch between the levels, different  
operations are needed with different codes. The three levels are Sealed, Unsealed, and Full Access.  
1. Full Access or Unsealed to Sealed: 0x0020 Instructs the bq20z80 to limit access to the SBS functions and  
data flash space and sets SBS.OperationStatus( ) [SS]. In sealed mode, standard SBS functions  
have access per the Smart Battery Data Specification - Appendix A. Extended SBS Functions and  
data flash are not accessible. Once in sealed mode, the part can never permanently return to  
Unsealed or Full Access modes.  
2. Sealed to Unsealed Instructs the bq20z80 to extend access to the SBS and data flash space and clears  
SBS.OperationStatus( ) [SS]. In unsealed mode, all data, SBS, and DF have read/write access.  
Unsealing is performed by using the SBS.ManufacturerAccess( ) command, and writing  
subsequently two unseal keys.  
The unseal keys can be read and changed via the extended SBS block command  
SBS.UnSealKey( ).  
To return to the Sealed mode, either a hardware reset is needed, or a command to transition from  
Full Access or Unsealed to Sealed.  
3. Unsealed to Full Access Instructs the bq20z80 to allow Full Access to all SBS commands and data flash.  
The bq20z80 is shipped from TI in this mode. The keys for Unsealed to Full Access can be read  
and changed via the extended SBS block command SBS.FullAccessKey( ) (0x61) when in Full  
Access mode. Change from Unsealed to Full Access is performed by using the  
SBS.ManufacturerAccess( ) command, and writing subsequently two Full Access keys. In Full  
Access mode, the command to go to Boot ROM can be sent.  
Also available via the SBS.ManufacturerAccess( ) commands are some of the extended SBS commands. The  
following commands available shown with the corresponding SBS.ManufacturerAccess( ) code.  
SBS.SafetyAlert( ) (0x0050)  
SBS.SafetyStatus( ) (0x0051)  
SBS.PFAlert( ) (0x0052)  
SBS.PFStatus( ) (0x0053)  
SBS.OperationStatus( ) (0x0054)  
SBS.ChargingStatus( ) (0x0055)  
SBS.ResetData( ) (0x0057)  
SBS.WDResetData( ) (0x0058)  
SBS.PackVoltage( ) (0x005a)  
SBS.AverageVoltage( ) (0x005d)  
RemainingCapacityAlarm( ) (0x01)  
This read or write function sets or gets a low-capacity alarm threshold unsigned integer value with a range of 0 to  
65535 and units of either mAh or 10 mWh depending on the setting of SBS.BatteryMode( ) [CAPACITY_MODE].  
See the SBS.BatteryMode( ) function for further information  
When the SBS.RemainingCapacity(  
)
is  
<
SBS.RemainingCapacityAlarm( ), the bq20z80 sends  
SBS.AlarmWarning( ) messages to the SMBus Host address with the Remaining_Capacity_Alarm (RCA) bit set.  
RCA is cleared when SBS.RemainingCapacity( ) is SBS.RemainingCapacityAlarm( ) AND SBS.BatteryStatus( )  
[DISCHARGING] is set.  
The default value of SBS.RemainingCapacityAlarm(  
SBS.RemainingCapacityAlarm( ) = 0, this alarm is disabled.  
)
is set in DF:Rem Cap Alarm. If  
29  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
If SBS.BatteryMode( ) [ALARM_MODE] is set, the SBS.AlarmWarning( ) message is disabled for a set time. See  
the SBS.BatteryMode( ) function for further information.  
SIZE  
(BYTES)  
DEFAULT  
VALUE  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
UNITS  
Rem Cap Alarm  
SBS Configuration / Data (48)  
Integer  
0 to 700  
2
mAh  
300  
RemainingTimeAlarm( ) (0x02)  
This read or write-word function sets or gets the Remaining Time Alarm unsigned integer value in minutes and  
with a range of 0 to 65,535.  
When the SBS.AverageTimeToEmpty(  
)
is  
<
SBS.RemainingTimeAlarm( ), the bq20z80 sends  
SBS.AlarmWarning( ) messages to the SMBus Host with the Remaining_Time_Alarm (RTA) bit set.  
The default value of SBS.RemainingTimeAlarm( ) is set in DF:Rem Time Alarm. If SBS.RemainingTimeAlarm( ) =  
0, this alarm is disabled.  
RTA is cleared when SBS.RemainingTimeAlarm(  
SBS.AverageTimeToEmpty( ) is increased by charging.  
) is SBS.AverageTimeToEmpty( ), or when the  
If SBS.BatteryMode( ) [ALARM_MODE] is set then the SBS.AlarmWarning( ) message is disabled for a set time.  
See the SBS.BatteryMode( ) function for further information.  
SIZE  
(BYTES)  
DEFAULT  
VALUE  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
UNITS  
Rem Time Alarm  
SBS Configuration / Data (48)  
Integer  
0 to 100  
2
s
10  
BatteryMode( ) (0x03)  
This read- or write-word function selects the various battery operational modes and reports the battery's  
capabilities, modes, and flags minor conditions requiring attention.  
BatteryMode( )  
High Byte  
bit7  
CapM  
CF  
bit6  
bit5  
AM  
bit4  
bit3  
bit2  
bit1  
PB  
bit0  
CC  
ChgM  
RSVD  
RSVD  
RSVD  
RSVD  
RSVD  
RSVD  
RSVD  
Low Byte  
RSVD  
PBS  
ICC  
The SBS.BatteryMode( ) word is divided into two halves, the High Byte which is read/write and the Low Byte  
which is read only. The default state of SBS.BatteryMode( ) is stored in DF:Init Battery Mode.  
FIELD  
FORMAT  
ALLOWABLE VALUES  
ICC = INTERNAL_CHARGE_CONTROLLER  
PBS = PRIMARY_BATTERY_SUPPORT  
Read Only Fixed to 1  
Read Only Fixed to 0  
0 – Battery OK  
1 – Conditioning Cycle Requested  
CF = CONDITION_FLAG  
Read Only  
CC = CHARGE_CONTROLLER_ENABLED  
PB = PRIMARY_BATTERY  
Read/Write Not used, Fixed to 0  
Read/Write Not use, Fixed to 0  
0 – Enable AlarmWarning( ) broadcasts to Host and Smart Battery Charger  
(default)  
AM = ALARM_MODE  
Read/Write  
1 – Disable AlarmWarning( ) broadcast to Host and Smart Battery Charger  
0 – Enable ChargingVoltage( ) and ChargingCurrent( ) broadcasts to Smart  
Battery Charger (default)  
ChgM = CHARGER_MODE  
CapM = CAPACITY_MODE  
Read/Write  
Read/Write  
1 – Disable broadcasts of ChargingVoltage( ) and ChargingCurrent( ) to  
Smart Battery Charger  
0 – Report in mA or mAh (default)  
1 – Report in 10 mW or 10 mWh  
30  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
NOTE:  
CF, AM, ChgM, and CapM are the only bits described as they are the only ones used  
in the bq20z80. See the SBD specification for details on the remaining bits.  
CONDITION_FLAG: Is initially set and is then permanently cleared when QMAX or the RA table have been  
updated.  
ALARM_MODE: Disables the bq20z80's ability to master the SMBus and send SBS.AlarmWarning( ) messages  
to the SMBus Host and the Smart Battery Charger.  
When ALARM_MODE = 1, the bq20z80 does not master the SMBus, and SBS.AlarmWarning( )  
messages are not sent to the SMBus Host and the Smart Battery Charger for a period of no more  
than 65 seconds and no less than 45 seconds. ALARM_MODE is automatically cleared by the  
bq20z80 60 seconds after being set to 1.  
When ALARM_MODE = 0 (default), the bq20z80 sends the SBS.AlarmWarning( ) messages to the  
SMBus Host and the Smart Battery Charger any time an alarm condition is detected.  
NOTE:  
The system, as a minimum, is required to poll the Smart Battery every 10 seconds if  
the ALARM_MODE bit is set.  
CHARGER_MODE: Enables or disables the bq20z80's transmission of SBS.ChargingCurrent( ) and  
SBS.ChargingVoltage( ) messages to the Smart Battery Charger.  
When CHARGER_MODE = 1, the bq20z80 does NOT transmit SBS.ChargingCurrent( ) and  
SBS.ChargingVoltage( ) values to the Smart Battery Charger.  
When CHARGER_MODE = 0 (default), the bq20z80 transmits the SBS.ChargingCurrent( ) and  
SBS.ChargingVoltage( ) values to the Smart Battery Charger when charging is desired.  
CAPACITY_MODE: Indicates if capacity information is reported in mA/mAh or 10 mW/10 mWh.  
When CAPACITY_MODE = 0 (default), the capacity information is reported in mA/mAh as appropriate. After  
changing the CAPACITY_MODE bit, the following functions are instanteously updated:  
SBS.RemainingCapacityAlarm( )  
SBS.AtRate( )  
SBS.RemainingCapacity( )  
SBS.FullChargeCapacity( )  
SBS.DesignCapacity( ), SBS.DesignCapacity( ) changes between DF:Design Capacity or DF:Design Energy  
depending on the CM bit transition.  
The following functions are calculated on the basis of capacity, and may be calculated differently depending on  
the CAPACITY_MODE bit:  
SBS.AtRateOK( )– Within 1s  
SBS.AtRateTimeToEmpty( )– Within 1s  
SBS.RunTimeToEmpty( )– Within 1s  
SBS.AverageTimeToEmpty( )– Within 1s  
SBS.RemainingTimeAlarm( )– Within 1s  
SBS.BatteryStatus( )– Within 1s  
SIZE  
(BYTES)  
DEFAULT  
VALUE  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
UNITS  
Init Battery Mode  
SBS Configuration / Data (48)  
Hex  
0x0000 to 0xffff  
2
N/A  
0x81  
AtRate( ) (0x04)  
This read- or write-word function is the first half of a two-function call set used to set the AtRate value used in  
calculations made by the SBS.AtRateTimeToFull( ), SBS.AtRateTimeToEmpty( ), and SBS.AtRateOK( )  
functions. The AtRate units are in either current (mA) or power (10 mW) depending on the setting of the  
SBS.BatteryMode( ) CAPACITY_MODE bit. See the SBS.BatteryMode( ) function for further information  
31  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
When the SBS.AtRate( ) value is positive, the SBS.AtRateTimeToFull( ) function returns the predicted time to  
full-charge at the AtRate value of charge. When the SBS.AtRate( value is negative, the  
)
SBS.AtRateTimeToEmpty( ) function returns the predicted operating time at the AtRate value of discharge. When  
the SBS.AtRate( ) value is negative, the SBS.AtRateOK( ) function returns a Boolean value that predicts the  
battery's ability to supply the AtRate value of additional discharge energy (current or power) for 10 seconds.  
The default value for SBS.AtRate( ) is zero. It is a signed integer where the SBS.AtRate( ) value is positive for  
charge, negative for discharge.  
AtRateTimeToFull( ) (0x05)  
This read-word function returns an unsigned integer value of the predicted remaining time to fully charge the  
battery using a CC-CV method at the SBS.AtRate( ) value in minutes, with a range of 0 to 65534. A value of  
65,535 indicates that the SBS.AtRate( ) = 0.  
SBS.AtRateTimeToFull( ) can report time based on constant current (SBS.BatteryMode( ) [CAPACITY_MODE] =  
0) or constant power (SBS.BatteryMode( ) [CAPACITY_MODE] = 1), and updates within one second after the  
SMBus host sets the SBS.AtRate( ) value. The bq20z80 automatically updates SBS.AtRateTimeToFull( ) based  
on the SBS.AtRate( ) at one-second intervals.  
AtRateTimeToEmpty( ) (0x06)  
This read-word function returns an unsigned integer value of the predicted remaining operating time in minutes  
with a range of 0 to 65534, if the battery is discharged at the SBS.AtRate( ) value. A value of 65,535 indicates  
that SBS.AtRate( ) = 0.  
SBS.AtRateTimeToEmpty( ) can report time based on constant current (SBS.OperationStatus( ) [Load_Mode] =  
0), or constant power (SBS.OperationStatus( ) [Load_Mode] = 1), and is updated within one second after the  
SMBus host sets the SBS.AtRate( ) value. The bq20z80 automatically updates SBS.AtRateTimeToEmpty( )  
based on the SBS.AtRate( ) at one-second intervals.  
AtRateOK( ) (0x07)  
This read-word function returns a Boolean value that indicates whether or not the battery can deliver the  
SBS.AtRate( )-value of additional energy for 10 seconds.  
If SBS.AtRate( ) is 0, the SBS.AtRateOK( ) function always returns OK (logic 1).  
The bq20z80 updates SBS.AtRateOK( ) within one second after the SMBus host sets the SBS.AtRate( ) value.  
The bq20z80 automatically updates SBS.AtRateOK( ) based on SBS.AtRate( ) at one-second intervals.  
Temperature( ) (0x08)  
This read-word function returns an unsigned integer value of the temperature in units of 0.1°K, as measured by  
the bq20z80. It has a range of 0 to 6553.5°K.  
The source of the measured temperature is configured by DF:Operation Cfg A [TEMP1, TEMP0].  
TEMP1  
TEMP0  
TEMPERATURE() SOURCE(1)  
Internal Temperature Sensor  
TS1 Input (default)  
0
0
1
1
0
1
0
1
Maximum of TS1 or TS2 Inputs  
Average of TS1 and TS2 Inputs  
(1) Both external temperature sensors, if used, MUST be the same type.  
32  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
Voltage( ) (0x09)  
This read-word function returns an unsigned integer value of the sum of the individual cell voltage measurements  
in mV with a range of 0 to 20000 mV.  
Current( ) (0x0a)  
This read-word function returns a signed integer value of the measured current being supplied (or accepted) by  
the battery in mA, with a range of –32,768 to 32,767. A positive value indicates charge current and negative  
indicates discharge.  
NOTE:  
SBS.Current( ) is the average of four internal current measurements over a  
one-second period.  
AverageCurrent( ) (0x0b)  
This read-word function returns a signed integer value that approximates a one-minute rolling average of the  
current being supplied (or accepted) through the battery terminals in mA, with a range of -32,768 to 32,767.  
SBS.AverageCurrent( ) is calculated by a rolling IIR filtered average of SBS.Current( ) data with a period of  
14.5s. During the time after a reset and before 14.5s has elapsed the reported SBS.AverageCurrent( ) =  
SBS.Current( ).  
MaxError( ) (0x0c)  
This read-word function returns an unsigned integer value of the expected margin of error, in %, in the  
state-of-charge calculation with a range of 1 to 100%.  
SBS.MaxError( ) is set to 100% on a full reset, and is updated by the following mechanism.  
On QMAX and Ra table update, the SBS.MaxError( ) is set to 1%.  
On QMAX update, the SBS.MaxError( ) is set to 3%  
On Ra table update, the SBS.MaxError( ) is set to 5%  
SBS.MaxError( ) is incremented 0.05% for every increment of SBS.CylceCount( ) after the last QMAX update  
RelativeStateOfCharge( ) (0x0d)  
This read-word function returns an unsigned integer value of the predicted remaining battery capacity expressed  
as a percentage of SBS.FullChargeCapacity( ), in %, with a range of 0 to 100%.  
AbsoluteStateOfCharge( )(0x0e)  
This read-word function returns an unsigned integer value of the predicted remaining battery capacity expressed  
as a percentage of SBS.DesignCapacity( ), in %, with a range of 0 to 100% with any fractions of % rounded up. If  
SBS.BatteryMode( ) [CAPACITY_MODE] is set, then the predicted remaining capacity is a percentage of  
SBS.RemainingCapacity( ) / SBS.Design Energy( ).  
NOTE:  
SBS.AbsoluteStateOfCharge( ) can return values > 100%.  
RemainingCapacity( ) (0x0f)  
This read-word function returns an unsigned integer value, with a range of 0 to 65535, of the predicted charge or  
energy remaining in the battery. The SBS.RemainingCapacity( ) value is expressed in either charge (mAh) or  
energy (10 mWh), depending on the setting of SBS.BatteryMode( ) [CAPACITY_MODE].  
33  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
FullChargeCapacity( ) (0x10)  
This read-word function returns an unsigned integer value, with a range of 0 to 65535, of the predicted pack  
capacity when it is fully charged. The SBS.FullChargeCapacity( ) value is expressed in either charge (mAh) or  
power (10 mWh) depending on the setting of SBS.BatteryMode( ) [CAPACITY_MODE].  
RunTimeToEmpty( ) (0x11)  
This read-word function returns an unsigned integer value of the predicted remaining battery life at the present  
rate of discharge, in minutes, with a range of 0 to 65,534 min. A value of 65,535 indicates battery is not being  
discharged.  
SBS.RunTimeToEmpty( ) is calculated and updated based on current or power, depending on the setting of  
SBS.BatteryMode( ) [CAPACITY_MODE].  
AverageTimeToEmpty( ) (0x12)  
This read-word function returns an unsigned integer value of predicted remaining battery life, in minutes, based  
upon SBS.AverageCurrent( ) with a range of 0 to 65534. A value of 65,535 indicates that the battery is not being  
discharged.  
AverageTimeToEmpty( ) is calculated based on current or power, depending on the setting of BatteryMode( )  
[CAPACITY_MODE].  
AverageTimeToFull( ) (0x13)  
This read-word function returns an unsigned integer value of predicted remaining time until the battery reaches  
full charge, in minutes, based on SBS.AverageCurrent( ) with a range of 0 to 65,535. A value of 65,534 indicates  
that the battery is not being charged.  
ChargingCurrent( ) (0x14)  
This read-word function returns an unsigned integer value of the desired charging rate, in mA, with a range of 0  
to 65,535. A value of 65,535 indicates that a charger should operate as a voltage source outside its maximum  
regulated current range.  
See Charging, 1st Level Safety and 2nd Level Safety sections of this data sheet for further details.  
ChargingVoltage( ) (0x15)  
This read-word function returns an unsigned integer value of the desired charging voltage, in mV, where the  
range is 0 to 65,534. A value of 65,535 indicates that the charger should operate as a current source outside its  
maximum regulated voltage range.  
Review the Charging, 1st Level Safety and 2nd Level Safety sections of this data sheet for further information on  
this command.  
BatteryStatus( ) (0x16)  
This read-word function returns the status of the bq20z80-based battery.  
SBS.BatteryStatus( ) [RCA, RTA] are calculated on the basis of either current or power depending on the setting  
of SBS.BatteryMode( ) [CAPACITY_MODE[.  
BatteryStatus( )  
High Byte  
bit7  
OCA  
INIT  
bit6  
TCA  
DSG  
bit5  
RSVD  
FC  
bit4  
OTA  
FD  
bit3  
TDA  
EC3  
bit2  
RSVD  
EC2  
bi1  
RCA  
EC1  
bit0  
RTA  
EC0  
Low Byte  
Alarm Bits  
OVER_CHARGED_ALARM (OCA): See Overcharge in the Charging section of this data sheet.  
TERMINATE_CHARGE_ALARM (TCA): See the Gas Gauging, Charging, 1st Level Safety, and 2nd Level  
Safety sections of this data sheet  
OVER_TEMP_ALARM (OTA): See Overtemperature functions in the 1st Level Safety and 2nd Level Safety  
34  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
sections of this data sheet.  
TERMINATE_DISCHARGE_ALARM (TDA): See the Gas Gauging,1st Level Safety and 2nd Level Safety  
sections of this data sheet.  
REMAINING_CAPACITY_ALARM (RCA): See SBS.RemainingCapacityAlarm( ) section of the data sheet.  
REMAINING_TIME_ALARM (RTA): See SBS.RemainingTimeAlarm( ) section of the data sheet.  
Status Bits  
INITIALIZED: Cleared after a full reset until all SBS parameters have been measured and updated (approx.  
1s).  
DISCHARGING: This bit is controlled under the following conditions.  
STATE  
CONDITION  
SBS.Current( ) DF:Quit Current for a period of DF:Charge Relax Time  
SBS.Current( ) DF:Quit Current AND valid charge termination has occurred  
SBS.Current( ) DF:Quit Current AND the CHG FET is turned OFF  
SBS.Current( ) (-) DF:Discharge Detection Current  
Set (1)  
Clear (0)  
SBS.Current( ) DF:Charge Detection Current  
FULLY_CHARGED: See the Charge and Discharge Alarms in Gas Gauging, Primary Charge Termination, and  
Overcharge functions in the Charging, 1st Level Safety, and 2nd Level Safety sections of this data  
sheet, respectively.  
FULLY_DISCHARGED: See the Charge and Discharge Alarms in Gas Gauging and 1st Level Safety and 2nd  
Level Safety sections of this data sheet  
ERRORS CODES  
EC3...EC0  
0x0  
DESCRIPTION  
The bq20z80 processed the function code with no errors detected.  
The bq20z80 is unable to process the function code at this time.  
OK  
Busy  
0x1  
The bq20z80 detected an attempt to read or write to a function code reserved by this version of the  
specification.  
Reserved  
0x2  
The bq20z80 detected an attempt to access an unsupported optional manufacturer function code.  
The bq20z80 does not support this function code as defined in this version of the specification.  
The bq20z80 detected an attempt to write to a read-only function code.  
The bq20z80 detected a data overflow or underflow.  
Unsupported  
AccessDenied  
Over/Underflow  
BadSize  
0x3  
0x4  
0x5  
0x6  
0x7  
The bq20z80 detected an attempt to write to a function code with an incorrect data block.  
The bq20z80 detected an unidentifiable error.  
UnknownError  
CycleCount( )(0x17)  
This read-word function returns, as an unsigned integer value, the number of cycles the battery has experienced,  
with a range of 0 to 65,534. The default value of SBS.CycleCount( ) is stored in DF:Cycle Count which is  
updated each time SBS.CycleCount( ) increments.  
If DF:Operation Cfg B [CCT] = 0, one cycle = the accumulated discharge of DF:CC Threshold.  
If DF:Operation Cfg  
B
[CCT]  
=
1, one cycle  
=
the accumulated discharge of DF:CC  
%
x
SBS.FullChargeCapacity( ).  
When SBS.OperationStatus( ) [SS] = 0 then this function is R/W.  
SIZE  
(BYTES)  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
UNITS  
DEFAULT VALUE  
CC Threshold  
Cycle Count  
CC %  
0 to 65535  
0 to 65535  
0 to 100  
2
2
1
mAh  
Counts  
%
4400  
0
SBS Configuration / Data (48)  
Integer  
90  
35  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
DesignCapacity( ) (0x18)  
This read-word function returns, as an unsigned integer value, the theoretical or nominal capacity of a new pack,  
stored in DF:Design Capacity or in DF:Design Energy.  
The SBS.DesignCapacity( ) value is expressed in either current (mAh at a C/5 discharge rate) or power, (10  
mWh at a P/5 discharge rate) depending on the setting of SBS.BatteryMode( ) [CAPACITY_MODE].  
When SBS.OperationStatus( ) [SS] = 0 then this function is R/W.  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
SIZE (BYTES)  
UNITS  
DEFAULT VALUE  
Design Capacity  
SBS Configuration / Data (48)  
Integer  
0 to 65535  
2
mAh  
4400  
DesignVoltage( ) (0x19)  
This read-word function returns an unsigned integer value of the theoretical voltage of a new pack, in mV, with a  
range of 0 to 65,534. The default value of SBS.DesignVoltage( ) is in DF:Design Voltage.  
When SBS.OperationStatus( ) [SS] = 0 then this function is R/W.  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
SIZE (BYTES)  
UNITS  
DEFAULT VALUE  
Design Voltage  
SBS Configuration / Data (48)  
Integer  
7000 to 18000  
2
mV  
14400  
SpecificationInfo( ) (0x1a)  
This read-word function returns, as an unsigned integer value, the version number of the Smart Battery  
Specification the battery pack supports, as well as voltage- and current-scaling information.  
Power scaling is the product of the voltage scaling times the current scaling. The SBS.SpecificationInfo( ) is  
packed in the following fashion:  
SpecID_H 0x10 + SpecID_L) + (VScale + IPScale 0x10) 0x100  
VScale (voltage scaling) and IPScale (current scaling) should always be set to zero. The default setting of  
SBS.SpecificationInfo( ) is in DF:Spec Info  
When SBS.OperationStatus( ) [SS] = 0 then this function is R/W.  
LABEL  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
SIZE (BYTES)  
UNITS  
DEFAULT VALUE  
Spec Info  
SBS Configuration / Data (48)  
Hex  
0x0000 to 0xffff  
2
Packed  
0x0031  
FIELD  
SpecID_L  
SpecID_H  
VScale  
BITS USED  
FORMAT  
ALLOWABLE VALUES  
0...3  
4...7  
4-bit binary value  
4-bit binary value  
4-bit binary value  
4-bit binary value  
0–15  
0–15  
8...11  
0 (multiplies voltage by 10VScale  
0 (multiplies current by 10IPScale  
)
)
IPScale  
12...15  
ManufactureDate( ) (0x1b)  
This read-word function returns the date the pack was manufactured in a packed integer. The date is packed in  
the following fashion:  
(year-1980) x 512 + month x 32 + day  
The default SBS.ManufactureDate( ). is in DF:Manuf Date.  
When SBS.OperationStatus( ) [SS] = 0 then this function is R/W.  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
SIZE (BYTES)  
UNITS  
DEFAULT VALUE  
Manuf Date  
SBS Configuration / Data (48)  
Integer  
0 to 65535  
2
Packed  
0
FIELD  
Date  
BITS USED  
FORMAT  
ALLOWABLE VALUES  
0...4  
5...8  
5-bit binary value  
4-bit binary value  
7-bit binary value  
0-31 (corresponds to date)  
Month  
Year  
1–12 (corresponds to month number)  
9...15  
0–127 (corresponds to year biased by 1980)  
36  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
SerialNumber( ) (0x1c)  
This read-word function is used to return an unsigned integer serial number. The default value of  
SBS.SerialNumber( ) is in DF:Serial Number.  
When SBS.OperationStatus( ) [SS] = 0 then this function is R/W.  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
SIZE (BYTES)  
UNITS  
DEFAULT VALUE  
Serial Number  
SBS Configuration / Data (48)  
Hex  
0x0000 to 0xffff  
2
N/A  
0
ManufacturerName( ) (0x20)  
This read-block function returns a character string containing the battery manufacturer's name with a maximum  
length of 11 characters (11 data + length byte).  
The default setting of SBS.ManufacturerName( ) is in DF:Manuf Name. When the bq20z80 is in unsealed or  
higher security mode, this block is R/W.  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
SIZE (BYTES)  
UNITS  
DEFAULT VALUE  
Manuf Name SBS Configuration / Data (48)  
Hex  
N/A  
11  
N/A  
Texas Inst.  
DeviceName( ) (0x21)  
This read-block function returns a character string that contains the battery name with a maximum length of 7  
characters (7 data + length byte).  
The default setting of SBS.DeviceName( ) is in DF:Device Name. When the bq20z80 is in Unsealed or higher  
security mode, this block is R/W.  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
SIZE (BYTES)  
UNITS  
DEFAULT VALUE  
Device Name  
SBS Configuration / Data (48)  
Hex  
N/A  
7
N/A  
bq20z80  
DeviceChemistry( ) (0x22)  
This read-block function returns a character string that contains the battery chemistry with a maximum length of 4  
characters (4 data + length byte).  
The default setting of SBS.DeviceChemistry( ) is in DF:Device Chemistry although it has no use for internal  
charge control or fuel gauging. When the bq20z80 is in Unsealed or higher security mode, this block is R/W.  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
SIZE (BYTES)  
UNITS  
DEFAULT VALUE  
Device Chemistry  
SBS Configuration / Data (48)  
Hex  
N/A  
4
mV  
LION  
ManufacturerData( ) (0x23)  
This read-block function returns several configuration data flash elements with an absolute maximum length of  
14 Data + 1 length byte (stored in Manufacturer Data Length). The Manufacturing data elements shown below  
are stored in the Manufacturer Data (56) subclass of the System Data class. When the bq20z80 is in Unsealed  
or higher security mode, this block is R/W.  
37  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
The data available is:  
MANUFACTURING DATA  
Lot Code of Pack  
Lot Code of PCB  
Firmware Version  
Hardware Revision  
Cell Revision  
Data stored in DF:Pack Lot Code as raw data  
2-bytes  
2-bytes  
1-byte  
Data stored in DF:PCB Lot Code as raw data  
Data stored in DF:Firmware Version as raw data  
Data stored in DF:Hardware Revision as raw data  
1-byte  
Data stored in DF:Cell Revision as raw data  
2-bytes  
SYSTEM DATA  
Reset Counter Partial  
Reset Counter Full  
Reset Counter Watch Dog  
Check Sum  
Count  
Count  
Count  
Number  
1-byte  
1-byte  
1-byte  
1-byte  
Authenticate( ) (0x2f)  
This read/write-block function allows the host to authenticate the bq20z80-based battery using a SHA-1  
authentication transform with a length of 20 data bytes + 1 length byte. See "Battery Authentication using the  
bq20z80" for further details.  
CellVoltage4( ) - CellVoltage1( ) (0x3c-0x3f)  
These read-word functions return an unsigned value of the calculated individual cell voltages, in mV, with a range  
of 0 to 65,534. SBS.CellVoltage1( ) corresponds to the bottom series element.  
EXTENDED SBS COMMANDS  
These commands are only available when the device is unsealed (SBS.OperationStatus( ) [SS] = 0). The  
standard set of commands is also available when unsealed.  
AFEData( ) (0x45)  
This read-block function returns the AFE memory map (9-bytes), beginning with AFE.0x00 as the MSB, and the  
internal AFE_Fail_Counter (2-bytes) returned with a maximum length of 11 data bytes + 1 length byte.  
FETControl( ) (0x46)  
This write/read-word function allows direct control of the FETs for test purposes using SMBus commands.  
FETStatus( )  
bit7  
bit6  
bit5  
bit4  
bit3  
bit2  
bi1  
bit0  
Low Byte  
RSVD  
RSVD  
RSVD  
OD  
ZVCHG  
CHG  
DSG  
RSVD  
When the bit is set, the FET is turned on. When the bit is cleared, the FET is turned off. The bq20z80 overrides  
these commands unless in normal gas-gauge operation. The DSG FET does not turn off if charge current is  
flowing, and the CHG FET does not turn off if discharge current is flowing. This protects the FET body diodes.  
RSVD (bit 0, 5, 6, 7) Reserved and should be 0  
DSG (bit 1) Discharge FET Control  
CHG (bit 2) Charge FET Control  
ZVCHG (bit 3) Zero-Volt (Pre-Charge) charge FET Control  
OD (bit 4) bq29312A OD Output Control  
StateOfHealth( ) (0x4f)  
This read-word function returns the state of health of the battery which is calculated by the formula:  
SBS.FullChargeCapacity( ) / 100 x DF:Design Capacity or SBS.FullChargeCapacity( ) / 100 x DF:Design  
Energy depending on the setting the SBS.BatteryMode( ) [CAPACITY] bit.  
38  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
SafetyAlert( ) (0x50)  
This read-word function returns indications of pending safety issues, such as when safety timers have started, or  
fail counters are nonzero but have not reached the required time or value to trigger an SBS.SafetyStatus( )  
change. The bit arrangement follows that of SBS.SafetyStatus( ). See the SBS.SafetyStatus( ) and 1st Level  
Safety sections of the data sheet for further details.  
SafetyStatus( ) (0x51)  
This read-word function returns the current status of the safety functions.  
SafetyStatus( )  
High Byte  
bit7  
OTD  
CUV  
bit6  
OTC  
COV  
bit5  
OCD  
PF  
bit4  
OCC  
bit3  
OCD2  
WDF  
bit2  
bi1  
bit0  
POV  
SCD  
OCC2  
AOCD  
PUV  
SCC  
Low Byte  
HWDG  
SCD  
SCC  
AOCD  
HWDG  
PF  
1 = Discharge short-circuit fault  
1 = Charge short-circuit fault  
1 = Discharge overcurrent fault  
1 = Host watchdog fault  
PUV  
1 = Pack undervoltage fault  
OCC2  
OCD2  
OCC  
OCD  
OTC  
OTD  
WDF  
1 = Tier-2 charge overcurrent fault  
1 = Tier-2 discharge overcurrent fault  
1 = Charge overcurrent fault  
1 = Permanent failure flag has been set  
1 = Cell overvoltage fault  
1 = Discharge overcurrent fault  
1 = Charge overtemperature fault  
1 = Discharge overtemperature fault  
1 = AFE watchdog fault  
COV  
CUV  
POV  
1 = Cell undervoltage fault  
1 = Pack overvoltage fault  
PFAlert( ) (0x52)  
This read-word function returns indications of pending permanent failure issues, such as when safety timers have  
started, or fail counters are nonzero, but have not reached the required time or value to trigger a DF:Permanent  
Failure Status change. The bit arrangement follows that of SBS.PFStatus( ) except for [AFE_C] and [AFE_P] as  
these have no alert. See the SBS.PFStatus( ), DF:PFStatus and Secondary Protection Features sections of the  
data sheet for further details.  
PFStatus( ) (0x53)  
The permanent failure status register indicates the source of the bq20z80 permanent-failure condition. The bit  
arrangement follows that of DF:PF Flags 1. See the DF:PF Flags 1 and 2nd Level Safety sections of the data  
sheet for further details.  
When any new cause of PF is detected in SBS.PFStatus( ), the new cause is added to DF:PF Flags 1. This  
allows DF:PF Flag 1 to show ALL of the different PF conditions that have occurred. On the first occasion of  
SBS.PFStatus( ) changing from 0x00 the value is stored to DF:PF Flag 2.  
OperationStatus( ) (0x54)  
This read-word function returns the current status of the operation status of the bq20z80.  
OperationStatus( )  
High Byte  
bit7  
bit6  
FAS  
DSG  
bit5  
SS  
bit4  
CSV  
bit3  
bit2  
Load Mode  
bi1  
bit0  
PRES  
WAKE  
Low Byte  
XDSG  
XDSGI  
VOK  
QEN  
QEN  
1 = QMAX updates are enabled  
VOK  
1 = Voltages are OK for a QMAX update  
1 = Discharge disabled due to a current issue  
1 = Discharge fault  
XDSGI  
XDSG  
DSG  
Replica of the SBS.BatteryStatus( ) [DISCHARGING] bit.  
WAKE  
1 = bq20z80 WAKE mode  
39  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
LoadMode Load mode for Impedance Track modeling. 0 = constant current, 1 = constant power  
CSV  
SS  
1 = Data Flash checksum value has been generated  
1 = Sealed mode  
FAS  
PRES  
0 = Full access security mode  
1 = PRES is low, indicating that the system is present (battery inserted).  
ChargingStatus( ) (0x55)  
This read-word function returns the current status of the charging functions.  
ChargingStatus( )  
High Byte  
bit7  
bit6  
CHGSUSP  
CB  
bit5  
bit4  
bit3  
bit2  
bi1  
FCHG  
OC  
bit0  
XCHG  
PCHG  
PCMTO  
MCHG  
FCMTO  
TCHG1  
OCHGV  
TCHG2  
OCHGI  
PULSE  
XCHGLV  
Low Byte  
PULSEOFF  
XCHG  
1 = Charging disabled  
CHGSUSP 1 = Charging suspend conditions exist  
PCHG  
MCHG  
TCHGx  
FCHG  
PULSE  
1 = Precharging conditions exist  
1 = Maintenance charging conditions exist  
1 = Temperature-based throttling of SBS.ChargingCurrent( ) conditions exist  
1 = Fast charging conditions exist  
1 = Pulse charging in progresss  
PULSEOFF 1 = Pulse charging has turned CHG FET OFF  
CB  
1 = Cell balancing in progress  
1 = Precharge timeout fault  
1 = Fast-charge timeout fault  
1 = Overcharge voltage fault  
1 = Overcharge current fault  
1 = Overcharge fault  
PCMTO  
FCMTO  
OCHGV  
OCHGI  
OC  
XCHGLV  
1 = Battery is depleted  
ResetData( ) (0x57)  
This read-word function returns the number of partial resets (low byte) and full resets (high byte) the device has  
experienced.  
WDResetData( ) (0x58)  
This read-word function returns the number of watchdog resets the device has experienced.  
PackVoltage( ) (0x5a)  
This read-word function returns an unsigned integer representing the measured voltage from the AFE pack pin,  
in mV, with a range of 0 to 65,534.  
AverageVoltage( ) (0x5d)  
This read-word function returns a signed integer value that approximates a one-minute rolling average of  
SBS.Voltage( ) in mV, with a range of 0 to 65,534.  
40  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
UnSealKey( ) (0x60)  
This read/write block (2-words) command allows the user to change the Unseal key for the Sealed-to-Unsealed  
security-state transition. This function is only available when the bq20z80 is in the Full-Access mode  
(SBS.OperationStatus( ), FAS is clear).  
FullAccessKey( ) (0x61)  
This read/write block (2-words) command allows the user to change the Full-Access security key for the  
Unsealed-to-Full-Access security-state transition. This function is only available when the bq20z80 is in the  
Full-Access mode (SBS.OperationStatus( ), FAS is clear).  
PFKey( ) (0x62)  
This read/write block (2-words) command allows the user to change the Permanent-Failure-Clear key. This  
function is only available when the bq20z80 is in the Full Access mode (SBS.OpertionStatus( ), FA is set).  
ManufacturerInfo( ) (0x70)  
This read-block function returns the data stored in DF:Manufacturer Info 1...8 (MfgInfo), where byte 1 is the MSB  
with a maximum length of 8 data + 1 length byte. When the bq20z80 is in Unsealed or Full Access mode, this  
block is R/W.  
SenseResistor( ) (0x71)  
This write-word command allows the user to change the sense resistor value used, in units of µΩ with a range of  
0 to 62535. The bq20z80 automatically updates the respective calibration data on receipt of a new sense resistor  
value.  
DataFlashClass( ) (0x77)  
This write word command sets the bq20z80 data flash subclass that is to be accessed by the  
SBS.DataFlashSubClass( ) commands that follow. These commands only allow access to the configuration data  
flash locations within the respective labeled subclass. See the Data Flash Access section for further details.  
A NACK is returned to the SBS.DataFlashClass( ) command if the value of the class is outside of the allowed  
range. The subclasses are defined in the Data Flash section of this data sheet.  
DataFlashSubClass( ) Commands  
These commands are used to access the consecutive 32-byte pages of each subclass.  
NOTE:  
Any DF location deemed Reserved responds with a NACK unless the bq20z80 is in  
the correct security state to allow access.  
DataFlashClassSubClass1( ) (0x78)  
DataFlashClassSubClass2( ) (0x79)  
DataFlashClassSubClass3( ) (0x7a)  
DataFlashClassSubClass4( ) (0x7b)  
DataFlashClassSubClass5( ) (0x7c)  
DataFlashClassSubClass6( ) (0x7d)  
DataFlashClassSubClass7( ) (0x7e)  
DataFlashClassSubClass8( ) (0x7f)  
41  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
DATA FLASH  
CAUTION:  
Care should be taken when mass programming the data flash space using  
previous verisons of data flash memory map files (such as *.gg files) to ensure  
all public locations are updated correctly.  
Data Flash can only be updated if SBS.Voltage( ) or SBS.PackVoltage( ) DF:Flash Update OK Voltage. Data  
flash reads and writes are verified according to the method detailed in the 2nd Level Safety section of this data  
sheet.  
Note: Data Flash updates are disabled when SBS.SafetyStatus( ) [PF] is set.  
Access  
In different security modes, the data flash access conditions change. See SBS.ManufacturerAccess( ) for further  
details.  
SECURITY MODE  
BootROM  
NORMAL DATA FLASH ACCESS  
N/A  
R/W  
R/W  
R
Full Access  
Unsealed  
Sealed  
Data Flash Interface  
The bq20z80 data flash is organized into subclasses where each data flash variable is assigned an offset within  
its numbered subclass. For example: the DF:Pre-chg Temperature threshold location is defined as:  
Class = Charge Control  
SubClass = Pre-Charge Config = 33  
Offset = 2  
Note: Data Flash commands are NACK'ed if SBS.OperationStatus( ) [SS=1].  
Each subclass can be addressed individually by using the SBS.DataFlashClass( ) command and the data within  
each subclass is accessed by using the SBS.DataFlashClassSubClassx( ) commands (0x78..0x7f).  
Reading and Writing subclass data are block operations which are 32 Bytes long but data can be written in  
shorter block sizes. The final block in the subclass can be shorted than 32 bytes so care must be taken as all  
bytes are overwritten correctly. None of the values written are bounded by the bq20z80 and the values are not  
rejected by the gas gauge. Writing an incorrect value may result in hardware failure due to firmware program  
interpretation of the invalid data. The data written is persistent, so a Power On Reset does resolve the fault.  
Reading a SubClass  
Information required:  
SubClassID  
Number of bytes in the subclass  
Variable Offset  
Procedure:  
1. Write the SubClassID using the SMBus Word Write protocol.  
Command = SubClassAccess command as specified in the data sheet (eg; Command 0x77)  
Word = SubClassID  
2. Read a block of data using SMBus Block Read protocol.  
Command = DataFlashClassSubClassx as specified in the data sheet (eg; Command 0x78)  
If a subclass has more than 32 bytes, then to get the next 32 bytes use Command =  
ReadSubClassCommand+1 (e.g. Command 0x79)  
42  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
Writing a SubClass  
Information required:  
SubClassID  
Number of bytes in the subclass  
32 bytes of initialized data to be written. Less than 32 bytes is acceptable if a subclass contains less than 32  
bytes in the last block.  
Procedure:  
1. Write the SubClassID using the SMBus Word Write protocol.  
Command = SubClassAccess command as specified in the data sheet  
Word = SubClassID  
2. Write a block of data using SMBus Block Write protocol.  
Command = DataFlashClassSubClassx as specified in the data sheet  
If a subclass has more than 32 bytes, then to get the next 32 bytes, use Command =  
DataFlashClassSubClassx +1  
Example  
To write the value of DF:Terminate Voltage to a value of 8.7 V the following sequence is used.  
Read complete Gas Gauging-IT Config subclass (SubclassID = 80) into RAM  
Write Subclass ID  
– SMB Slave Address (0x16)  
– SMB CMD 0x77 with 0x0050 as data  
Read Subclass (2 blocks are needed as its over 32 bytes long)  
– SMBSlave Address (0x16)  
– SMB CMD 0x78 receiving 32 bytes of data  
– SMB CMD 0x79 receiving 32 bytes of data  
Overwrite offset 38 of received data with 8.7 V  
Update offset 38 with 0x21fc  
Write the complete subclass back to the bq20z80  
Write Subclass ID  
– SMB Slave Address (0x16)  
– SMB CMD 0x77 with 0x0050 as data  
Write Subclass  
– SMB Slave Address (0x17)  
– SMB CMD 0x78 with 32 bytes of data  
– SMB CMD 0x79 with 32 bytes of data  
Alternatively, only the required block rather than the full subclass can be accessed.  
Read required block of Gas Gauging-IT Config subclass (SubclassID = 80) into RAM  
Write Subclass ID  
– SMB Slave Address (0x17)  
– SMB CMD 0x77 with 0x0050 as data  
Read Subclass (2nd block is needed as its offset 38)  
– SMB Slave Address (0x16)  
– SMB CMD 0x79 receiving 32 bytes of data  
Overwrite offset (38 - 32 = 6) of received data with 8.7 V  
Update offset 6 with 0x21fc  
Write the updated block back to the bq20z80  
Write Subclass ID  
43  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
– SMB Slave Address (0x17) SMB CMD 0x77 with 0x0050 as data  
Write Subclass  
– SMB Slave Address (0x17)  
– SMB CMD 0x79 with 32 bytes of data  
44  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
Table 3. SubClass and Offset Table  
Size (Bytes)  
Unsigned Int  
unless noted  
Class/Subclass  
SubClassID / Offset  
Configurable Value  
1st Level Safety  
Voltage  
0
0
COV Threshold  
COV Time  
2
1
2
1
1
2
1
2
2
1
2
2
1
2
2
3
COV Recovery  
COV Delta  
5
6
COV Temp. Hys  
POV Threshold  
POV Time  
7
9
10  
12  
14  
15  
17  
19  
20  
1
POV Recovery  
CUV Threshold  
CUV Time  
CUV Recovery  
PUV Threshold  
PUV Time  
PUV Recovery  
Current  
0
OC (1st Tier) Chg  
2
2
OC (1st Tier) Chg Time  
OC Chg Recovery  
OC (1st Tier) Dsg  
1
3
Int: 2  
5
2
7
OC (1st Tier) Dsg Time  
OC Dsg Recovery  
1
8
2
2
10  
12  
13  
15  
16  
17  
18  
19  
21  
22  
23  
2
OC (2nd Tier) Chg  
OC (2nd Tier) Chg Time  
OC (2nd Tier) Dsg  
OC (2nd Tier) Dsg Time  
Current Recovery Timer  
AFE OC Dsg  
1
2
1
1
Hex: 1  
Hex: 1  
Hex: 2  
Hex: 1  
Hex: 1  
Hex: 2  
AFE OC Dsg Time  
AFE OC Dsg Recovery  
AFE SC Chg Config  
AFE SC Dsg Config  
AFE SC Recovery  
Temperature  
0
Over Temp Chg  
OT Chg Time  
2
1
2
2
1
2
2
3
OT Chg Recovery  
Over Temp Dsg  
OT Dsg Time  
5
7
8
OT Dsg Recovery  
Host Comm  
3
0
Host Watchdog Timeout  
SOV Threshold  
1
2
2nd Level Safety  
Voltage  
16  
0
45  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
Table 3. SubClass and Offset Table (continued)  
Size (Bytes)  
Unsigned Int  
unless noted  
Class/Subclass  
SubClassID / Offset  
Configurable Value  
2
3
SOV Delay  
1
1
2
1
1
1
Cell Imbalance Current  
Cell Imbalance Fail Voltage  
Cell Imbalance Time  
Battery Rest Time  
4
6
7
8
PFIN Detect Time  
Current  
17  
0
SOC Chg  
2
1
2
1
2
SOC Chg Time  
SOC Dsg  
3
5
SOC Dsg Time  
Temperature  
18  
0
SOT Chg  
2
1
2
SOT Chg Time  
SOT Dsg  
3
2
5
SOT Dsg Time  
Open Thermistor  
Open Time  
1
6
Int: 2  
Int: 1  
8
FET Verification  
AFE Verification  
19  
0
FET Fail Limit  
FET Fail Time  
2
1
2
20  
0
AFE Check Time  
AFE Fail Limit  
1
1
1
1
1
1
2
AFE Fail Recovery Time  
AFE Init Retry Limit  
AFE Init Limit  
3
4
Fuse Verification  
21  
0
Fuse Fail Limit  
Fuse Fail Time  
2
1
2
Charge Control  
Charge Inhibit Config  
32  
0
Chg Inhibit Temp Low  
Chg Inhibit Temp High  
Temp Hys  
Int: 2  
Int: 2  
Int: 2  
2
4
Pre-Charge Config  
Fast Charge Config  
33  
0
Pre-chg Current  
2
Int: 2  
2
2
Pre-chg Temperature  
Pre-chg Voltage  
4
6
Recovery Voltage  
2
34  
0
Fast Charge Current  
Charging Voltage  
Over Charging Voltage  
Delta Temp  
2
2
2
4
2
6
Int: 2  
Int: 2  
8
Suspend Low Temp  
46  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
Table 3. SubClass and Offset Table (continued)  
Size (Bytes)  
Unsigned Int  
unless noted  
Class/Subclass  
SubClassID / Offset  
Configurable Value  
Suspend High Temp  
10  
35  
0
Int: 2  
Pulse Charge Config  
Turn On Voltage  
Turn Off Voltage  
Max ON Pulse Time  
Min OFF Pulse Time  
Max Off Voltage  
2
2
1
1
2
2
4
5
6
Termination Config  
36  
0
Maintenance Current  
Taper Current  
2
2
2
6
Termination Voltage  
Current Taper Window  
TCA Set %  
2
8
2
10  
11  
12  
13  
37  
0
Int: 1  
Int: 1  
Int: 1  
Int: 1  
TCA Clear %  
FC Set %  
FC Clear %  
Cell Balancing Config  
Charging Faults  
Min Cell Deviation  
2
38  
0
Over Charging Voltage  
Overcharge Voltage Time  
Over Charging Current  
Overcharge Current Time  
Overcharge Recovery Current  
Depleted Voltage  
2
2
1
3
2
5
1
6
2
8
2
10  
11  
13  
15  
17  
19  
21  
Depleted Voltage Time  
Depleted Recovery  
Over Charge Capacity  
Over Chg Recovery  
FC-MTO  
1
2
2
2
2
2
PC-MTO  
Charge Fault Cfg  
Hex: 1  
SBS Configuration  
Data  
48  
0
Rem Cap Alarm  
Rem Time Alarm  
Init Battery Mode  
Design Voltage  
Spec. Info  
2
2
2
4
Hex: 2  
6
2
8
Hex: 2  
10  
12  
14  
16  
18  
19  
21  
Manuf Date  
2
Ser Num  
Hex: 2  
Cycle Count  
CC Threshold  
CC %  
2
2
1
2
2
Design Capacity  
Design Energy  
47  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
Table 3. SubClass and Offset Table (continued)  
Size (Bytes)  
Unsigned Int  
unless noted  
Class/Subclass  
SubClassID / Offset  
Configurable Value  
23  
35  
43  
49  
0
Manuf Name  
Device Name  
String: 12  
String: 8  
String: 5  
Device Chemistry  
Config  
TDA Set %  
Int: 1  
1
TDA Clear %  
FD Set %  
Int: 1  
2
Int: 1  
3
FD Clear %  
Int: 1  
4
TDA Volt Threshold  
TDA Volt Time  
TDA Recovery  
FD Volt Threshold  
FD Volt Time  
FD Recovery  
2
1
2
2
1
2
6
7
9
11  
12  
System Data  
Manufacturer Data  
56  
0
Pack Lot Code  
PCB Lot Code  
Firmware Version  
Hardware Revision  
Cell Revision  
Hex: 2  
Hex: 2  
Hex: 2  
Hex: 2  
Hex: 2  
2
4
6
8
Manufacturer Info  
Lifetime Data  
58  
0
Manuf. Info  
String: 9  
59  
0
Lifetime Max Temp  
Int: 2  
Int: 2  
Int: 2  
Int: 2  
Int: 2  
Int: 2  
Int: 2  
Int: 2  
Int: 2  
Int: 2  
Int: 2  
Int: 2  
Int: 2  
2
Lifetime Min Temp  
4
Lifetime Max Cell Voltage  
Lifetime Min Cell Voltage  
Lifetime Max Pack Voltage  
Lifetime Min Pack Voltage  
Lifetime Max Chg Current  
Lifetime Max Dsg Current  
Lifetime Max Chg Pwr  
Lifetime Max Dsg Pwr  
Life Max AvgDsg Cur  
Life Max AvgDsg Pow  
Lifetime Avg Temp  
6
8
10  
12  
14  
16  
18  
22  
26  
28  
60  
0
Lifetime Temp Samples  
LT Temp Samples  
4
Configuration  
Registers  
64  
0
Operation Cfg A  
Operation Cfg B  
Permanent Fail Cfg  
Nonremovable Cfg  
Hex: 2  
Hex: 2  
Hex: 2  
Hex: 2  
2
4
6
LED Support  
48  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
Table 3. SubClass and Offset Table (continued)  
Size (Bytes)  
Unsigned Int  
unless noted  
Class/Subclass  
SubClassID / Offset  
Configurable Value  
LED  
67  
0
LED Flash Rate  
2
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
2
LED Blink Rate  
LED Delay  
4
6
LED Hold Time  
CHG Flash Alarm  
CHG Thresh. 1  
CHG Thresh. 2  
CHG Thresh. 3  
CHG Thresh. 4  
CHG Thresh. 5  
DSG Flash Alarm  
DSG Thresh. 1  
DSG Thresh. 2  
DSG Thresh. 3  
DSG Thresh. 4  
DSG Thresh. 5  
7
8
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
Power  
Power  
68  
0
Flash Update OK Voltage  
Shutdown Voltage  
Shutdown Time  
2
2
2
4
1
5
Charger Present  
2
2
7
Sleep Current  
9
Bus Low Time  
1
10  
12  
14  
15  
Cal Inhibit Temp Low  
Cal Inhibit Temp High  
Sleep Voltage Time  
Sleep Current Time  
Int: 2  
Int: 2  
1
1
Gas Gauging  
IT Config  
80  
0
Load Select  
1
1
Load Mode  
1
41  
56  
58  
60  
62  
81  
0
Term Voltage  
Int: 2  
Int: 2  
Int: 2  
Int: 2  
Int: 2  
User Rate (mA)  
User Rate (10 mW)  
ReservCap (mAh)  
ReservCap (10 mWh)  
Current Thresholds  
Dsg Current Threshold  
Chg Current Threshold  
Quit Current  
2
2
2
1
1
2
4
6
Dsg Relax Time  
7
Chg Relax Time  
State  
82  
49  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
Table 3. SubClass and Offset Table (continued)  
Size (Bytes)  
Unsigned Int  
unless noted  
Class/Subclass  
SubClassID / Offset  
Configurable Value  
0
2
Qmax Cell 0  
Qmax Cell 1  
Qmax Cell 2  
Qmax Cell 3  
Qmax Pack  
2
2
4
2
6
2
8
2
12  
21  
23  
25  
Update Status  
Avg I Last Run  
Hex: 2  
Int: 2  
Int: 2  
Int: 2  
Avg P Last Run  
Delta Voltage  
Ra Table  
R_a0  
88  
0
Cell0 R_a flag  
Hex: 2  
2 to 30  
Cell0 R_a 0 to Cell0 R_a 14  
Int: 2 each  
R_a1  
89  
0
2 to 30  
90  
Cell1 R_a flag  
Hex: 2  
Cell1 R_a 0 to Cell1 R_a 14  
Int: 2 each  
R_a2  
0
Cell2 R_a flag  
Hex: 2  
2 to 30  
91  
Cell2 R_a 0 to Cell2 R_a 14  
Int: 2 each  
R_a3  
0
Cell3 R_a flag  
Hex: 2  
2 to 30  
92  
Cell3 R_a 0 to Cell3 R_a 14  
Int: 2 each  
R_a0x  
R_a1x  
R_a2x  
R_a3x  
PF Status  
0
xCell0 R_a flag  
Hex: 2  
2 to 30  
93  
xCell0 R_a 0 to xCell0 R_a14  
Int: 2 each  
0
xCell1 R_a flag  
Hex: 2  
2 to 30  
94  
xCell1 R_a 0 to xCell1 R_a 14  
Int: 2 each  
0
xCell2 R_a flag  
Hex: 2  
2 to 30  
95  
xCell2 R_a 0 to xCell2 R_a 14  
Int: 2 each  
0
xCell3 R_a flag  
Hex: 2  
2 to 30  
xCell3 R_a 0 to xCell3 R_a 14  
Int: 2 each  
Device Status Data  
96  
0
PF Flags 1  
Hex: 2  
2
Fuse Flag  
Hex: 2  
4
PF Voltage  
2
6
PF C1 Voltage  
PF C2 Voltage  
PF C3 Voltage  
PF C4 Voltage  
PF Current  
2
8
2
10  
12  
14  
16  
18  
2
2
Int: 2  
2
PF Temperature  
PF Batt Stat  
Hex: 2  
50  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
Table 3. SubClass and Offset Table (continued)  
Size (Bytes)  
Unsigned Int  
unless noted  
Class/Subclass  
SubClassID / Offset  
Configurable Value  
20  
22  
24  
26  
28  
97  
0
PF RC - mAh  
Int: 2  
Int: 2  
PF RC - 10mWh  
PF Chg Status  
PF Safety Status  
PF Flags 2  
Hex: 2  
Hex: 2  
Hex: 2  
AFE Regs  
AFE Status  
AFE Output  
AFE State  
AFE Function  
AFE Cell Select  
AFE OLV  
Hex: 1  
Hex: 1  
Hex: 1  
Hex: 1  
Hex: 1  
Hex: 1  
Hex: 1  
Hex: 1  
Hex: 1  
1
2
3
4
5
6
AFE OLT  
7
AFE SCC  
8
AFE SCD  
Calibration  
Data  
104  
0
CC Gain  
Float: 4  
Float: 4  
Int: 2  
Int: 2  
2
4
CC Delta  
8
Ref Voltage  
AFE Corr  
10  
12  
14  
16  
17  
18  
19  
105  
0
AFE Pack Gain  
CC Offset  
Int: 2  
Int: 1  
Int: 1  
Int: 1  
Int: 1  
Board Offset  
Int Temp Offset  
Ext1 Temp Offset  
Ext2 Temp Offset  
Config  
CC Current  
2
2
2
2
2
2
2
2
2
2
Voltage Signal  
Temp Signal  
4
6
CC Offset Time  
ADC Offset Time  
CC Gain Time  
Voltage Time  
8
10  
12  
14  
17  
106  
0
Temperature Time  
Cal Mode Timeout  
Temp Model  
Ext Coef 1  
Ext Coef 2  
Ext Coef 3  
Ext Coef 4  
Ext Min AD  
Ext Max Temp  
Int Coef 1  
Int: 2  
Int: 2  
Int: 2  
Int: 2  
Int: 2  
Int: 2  
Int: 2  
Int: 2  
2
4
6
8
10  
12  
14  
Int Coef 2  
51  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
Table 3. SubClass and Offset Table (continued)  
Size (Bytes)  
Unsigned Int  
unless noted  
Class/Subclass  
SubClassID / Offset  
Configurable Value  
16  
18  
20  
22  
107  
0
Int Coef 3  
Int: 2  
Int: 2  
Int: 2  
Int: 2  
Int Coef 4  
Int Min AD  
Int Max Temp  
Current  
Filter  
1
1
1
1
2
2
1
Deadband  
CC Deadband  
2
3
CC Max Deadband  
4
CC Deadband Sample  
CC Max Offset Sample  
6
Operation Cfg A  
OPERATION  
CONFIGURATION A  
bit7  
bit6  
bit5  
bit4  
bit3  
bit2  
bi1  
bit0  
High Byte  
Low Byte  
LEDR  
RSVD  
LEDRCA  
RSVD  
CHGLED  
SLEEP  
DMODE  
TEMP1  
LED1  
LED0  
SLED  
CC1  
CC0  
TEMP0  
ZVCHG1  
ZVCHG0  
The Operation Cfg bits enable, disable, and configure various features of the bq20z80.  
RSVD These bits are reserved and MUST be programmed to 0.  
ZVCHG0, ZVCHG1 These bits enable or disable the use of ZVCHG or CHG FET for Zero-Volt/Precharge modes.  
ZVCHG1  
ZVCHG0  
FET USED  
ZVCHG  
CHG  
0
0
1
1
0
1
0
1
OD  
No Action  
SLED  
Enables the bq20z80 display to be used in serial or parallel mode.  
0 = Display is in parallel LED mode (default)  
1 = Display is in serial LED mode  
TEMP0, TEMP1 These bits select the measurement source used for SBS.Temperature( ).  
TEMP1  
TEMP0  
TEMPERATURE() SOURCE  
Internal Temperature Sensor  
TS1 Input (default)  
0
0
1
1
0
1
0
1
Maximum of TS1 or TS2 Inputs  
Average of TS1 and TS2 Inputs  
SLEEP  
Enables the bq20z80 to enter Sleep mode.  
0 =  
1 =  
bq20z80 never enters Sleep  
bq20z80 enters Sleep mode under normal Sleep entry requirements  
CC0, CC1  
These bits configure the bq20z80 for the number of series cells in the battery stack.  
52  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
CC1  
CC0  
NUMBER OF SERIES CELLS  
0
0
1
1
0
1
0
1
Reserved  
2
3
4
LED0, LED1  
These bits configure the number of LEDs used in the LED Display.  
LED1  
LED0  
NUMBER OF LEDs USED  
0
0
1
1
0
1
0
1
User(1)  
3
4
5
(1) When User configuration selected, the LEDs are controlled as shown in the Display Format tables.  
See Display section of this data sheet for further details.  
DMODE  
This bit sets the display as Relative or Absolute mode.  
0 = Display reflects SBS.RelativeStateOfCharge( )  
1 = Display reflects SBSAbsoluteStateOfCharge( )  
CHGLED  
LEDRCA  
LEDR  
Enables display while charging.  
0 = Display not activated by charging, requires push-button event or SMBus command.  
1 = Display active during charging.  
Enables activation of the LED display when SBS.BatteryStatus( ) [RCA] is set.  
0 = LED display is not activated when SBS.BatteryStatus( ) [RCA] is set.  
1 = LED display is activated (simulates a DISP transition) when SBS.BatteryStatus( ) [RCA] is set.  
Enables activation of the LED display on device-reset exit.  
0 = LED display is not activated on exit from device reset.  
1 = LED display is activated (simulates a DISP transition) on exit from device reset.  
Operation Cfg B  
OPERATION  
CONFIGURATION B  
bit7  
bit6  
bit5  
bit4  
bit3  
bit2  
bi1  
bit0  
High Byte  
Low Byte  
PFD1  
PFD0  
RESCAP  
CHGFET  
NCSMB NRCHG CSYNC CHGTERM  
CHGIN NR CPE HPE  
CCT  
CHGSUSP  
OTFET  
BCAST  
BCAST  
HPE  
This bit enables or disables SBS broadcasts to smart charger and host.  
0 = Broadcasts to host and charger disabled  
1 = Broadcasts to host and charger enabled  
This bit enables or disables PEC transmissions to the smart-battery host for master-mode alarm  
messages.  
0 = No PEC byte on alarm warning to host  
1 = PEC byte on alarm warning to host  
53  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
CPE  
This bit enables or disables PEC transmissions to the smart-battery charger for master-mode alarm  
messages.  
0 = No PEC byte on alarm warning to charger  
1 = PEC byte on alarm warning to charger  
NR  
This bit can set the bq20z80 in non-removable battery mode and determines the recovery method  
for current based Primary Protection features.  
0 = Removable battery mode  
1 = Non-removable battery mode  
CHGIN  
This bit can set enable the CHG FET (and ZVCHG FET if used) to turn off when the bq20z80 is in  
charge-inhibit mode.  
0 = No FET change in charge-inhibit mode.  
1 = Charge and ZVCHG, if used, turn off in charge-inhibit mode.  
CHGFET  
OTFET  
This bit enables or disables the CHG FET from reacting to a valid charge termination.  
0 = CHG FET stays on at charge termination.  
1 = CHG FET turns off at charge termination.  
This bit enables or disables FET actions from reacting to an overtemperature fault.  
0 = There is NO FET action when an overtemperature condition is detected.  
1 = When SBS.SafetyStatus( ) [OTC] is set then the CHG FET is turned off and when  
SBS.SafetyStatus( ) [OTD] is set then the DSG FET is turned off  
CHGSUSP This bit can enable the CHG FET (and ZVCHG FET if used) to turn off when the bq20z80 is in  
Charge Suspend mode.  
0 = No FET change in Charge Suspend mode.  
1 = Charge and ZVCHG, if used, turns off in Charge Suspend mode.  
CCT  
This bit sets the format of the Cycle Count Threshold.  
0 = DF:Cycle Count is a fixed mAh value.  
1 = DF:Cycle Count is in % of SBS.FullChargeCapacity( ).  
CHGTERM This bit enables or disables SBS.BatteryStatus( ) [TCA, FC] to be cleared after charger termination  
confirmed.  
0 = SBS.BatteryStatus( ) [TCA, FC] are not cleared by charge termination confirmation, but are  
cleared by other means.  
1 = SBS.BatteryStatus( [TCA, FC] are cleared when SBS.Current( ) < DF:Chg Current Threshold  
for a period of 2 x DF:Current Taper Window. Note: This does notdisable clearing by  
DF:TCA_Clear and DF:FC_Clear.  
CSYNC  
Enables the bq20z80 to write SBS.RemainingCapacity( ) to equal SBS.FullChargeCapacity( ) when  
a valid charge termination is detected.  
54  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
0 = SBS.RemainingCapacity( ) is not modified on valid charge termination  
1 = SBS.RemainingCapacity( ) is written up to equal SBS.FullChargeCapacity( ) on valid charge  
termination .  
NRCHG  
NCSMB  
RESCAP  
Enables the charge FET to remain on during sleep when DF:Operation Cfg B [NR] is set  
0 = Charge FET turns off in Sleep (default)  
1 = Charge FET remains on in Sleep  
Enables extended SMBUS tTIMEOUT  
0 = Normal SMBUS tTIMEOUT (default)  
1 = Extended SMBUS tTIMEOUT  
This bit configures the compensation model for the DF:Reserve Cap-mAh and DF:Reserve  
Cap-10mWh.  
0 = Light Load (C/20) Compensation  
1 = SBS.AverageLoad( ) Compensation  
PFD1,0  
Configure the Permanent Failure LED display (disabled if SBS.Operation Cfg A [SLED] = 1)  
PFD1  
PFD0  
OPERATION  
0
0
1
1
0
1
0
1
PF Display not available  
PF Display is activated after SOC display if DISP is held low for tLED_HOLD  
PF Display not available  
PF Display is automatically activated after SOC display  
Nonremovable Configuration  
NONREMOVABLE  
bit7  
bit6  
bit5  
bit4  
bit3  
bit2  
bi1  
bit0  
CONFIGURATION  
High Byte  
Low Byte  
OCD  
OCC  
OCD2  
OCC2  
AOCD  
SCC  
SCD  
The DF:Non-Removable Cfg bits enable the current protection recovery features to be treated differently based  
on DF:Operation Cfg A [NR]. The additional recovery features are detailed with the individual features in the 1st  
Level Safety section of this data sheet.  
SCD  
= Short Circuit in Discharge  
= Short Circuit in Charge  
SCC  
AOCD  
OCC2  
OCD2  
OCC  
= AFE Overcurrent in Discharge  
= Overcurrent in Charge - Tier 2  
= Tier-2 Overcurrent, Discharge  
= Overcurrent in Charge  
OCD  
= Overcurrent in Discharge  
PF Flags 1  
The permanent failure flags 1 register indicates the reason that bq20z80 has entered permanent failure.  
PF FLAGS 1  
bit7  
bit6  
bit5  
bit4  
bit3  
bit2  
bi1  
bit0  
High Byte  
FBF  
SOPT  
SOCD  
SOCC  
AFE_P  
AFE_C  
55  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
PF FLAGS 1  
bit7  
bit6  
bit5  
bit4  
bit3  
bit2  
bi1  
bit0  
Low Byte  
DFF  
DFETF  
CFETF  
CIM  
SOTD  
SOTC  
SOV  
PFIN  
PFIN  
Set on External Input Indication of permanent failure  
Set on a Safety-Overvoltage permanent failure  
SOV  
SOTC  
SOTD  
CIM  
Set on a Charge Safety Overtemperature permanent failure  
Set on a Discharge Safety Overtemperature permanent failure  
Set on a Cell-Imbalance permanent failure  
CFETF  
DFETF  
DFF  
Set on a Charge-FET-Failure permanent failure  
Set on a Discharge-FET-Failure permanent failure  
Set on a Data Flash Fault permanent failure  
AFE_C  
AFE_P  
SOCC  
SOCD  
SOPT  
FBF  
Set on an AFE-Communications permanent failure  
Set on a Periodic-AFE-Communications permanent failure  
Set on a Charge Safety-Overcurrent permanent failure  
Set on a Discharge Safety Overcurrent in permanent failure  
Set on an Open Thermistor permanent failure  
Set when the fuse has not cut off current, even though the output has been driven low  
Permanent Fail Cfg  
The Permanent Failure Configuration register enables or disables the use of the SAFE and SAFE pins when the  
corresponding DF:PF Flags 1 flag is set.  
PERMANENT FAILURE  
bit7  
bit6  
bit5  
bit4  
bit3  
bit2  
bi1  
bit0  
CFG  
High Byte  
Low Byte  
XSOCD  
XSOTD  
XSOCC  
XSOTC  
XAFE_P  
XSOV  
XAFE_C  
XPFIN  
XDFF  
XDFETF  
XCFETF  
XCIM  
If corresponding DF:PF Flags 1 AND DF:Permanent Fail Cfg bits are set (1), the SAFE output is driven and  
latched low and the SAFE output is driven and latched high. This does not include DF:PF Flags 1 [FBF].  
Lifetime Data  
Lifetime Maximum Temperature: This data flash value is updated if the current SBS.Temperature( ) is > the  
current DF:Lifetime Max Temp value for a time > 60s OR an increment > 1.0°C.  
Lifetime Minimum Temperature: This data flash value is updated if the current SBS.Temperature( ) is < the  
current DF:Lifetime Min Temp value for a time > 60s, OR an increment > 1.0°C.  
Lifetime Maximum Cell Voltage: This data flash value is updated if any SBS.CellVoltagex( ) is > the current  
DF:Lifetime Max Cell Voltage value for a time > 60s, OR an increment > 25 mV.  
Lifetime Minimum Cell Voltage: This data flash value is updated if the current SBS.CellVoltagex( ) is < the  
current DF:Lifetime Min Cell Voltage value for a time > 60s, OR an increment > 25 mV.  
Lifetime Maximum Pack Voltage: This data flash value is updated if the current SBS.Voltage( ) is > the current  
DF:Lifetime Max PackVoltage value for a time > 60s, OR an increment > 100 mV.  
Lifetime Minimum Pack Voltage: This data flash value is updated if the current SBS.Voltage( ) is < the current  
Lifetime Min Pack Voltage value for a time > 60s, OR an increment > 100 mV.  
Lifetime Maximum Charge Current: This data flash value is updated if the current SBS.AverageCurrent( ) is >  
the current DF:Lifetime Max Chg Current value, and SBS.AverageCurrent( ) is positive (charge) for  
a time > 60s, OR an increment > 100 mA.  
Lifetime Maximum Discharge Current: This data flash value is updated if the current SBS.AverageCurrent ( )  
is > the current DF:Lifetime Max Dsg Current value, and SBS.AverageCurrent( ) is negative  
56  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
(discharge) for a time > 60s, OR an increment > 100 mA.  
Lifetime Maximum Charge Power: This data flash value is updated when SBS.AveragePower( ) is > the current  
DF:Lifetime Max Chg Power value for a time > 60s, OR an increment > 1000 mW.  
Lifetime Maximum Discharge Power: This data flash value is updated when SBS.AveragePower( ) is > the  
current DF:Lifetime Max Dsg Power value for a time > 60s, OR an increment > 1000 mW.  
Lifetime Average Temperature: DF:Lifetime Avg Temp is updated when the average of SBS.Temperature( )  
exceeds the range of the present value by ± 1°C. The average is calculated as a simple average of  
all the valid temperature readings.  
When any of the Lifetime data value is triggered to be updated then ALL Lifetime data is updated to data flash.  
However, no Lifetime Data is updated until SBS.StatusUpdate( ) [ITEN] is set.  
SIZE  
(BYTES)  
DEFAULT  
VALUE  
NAME  
CLASS / SUBCLASS  
FORMAT  
Signed Int  
Integer  
VALID RANGE  
UNITS  
Lifetime Max Temp  
Lifetime Min Temp  
0 to 1400  
-600 to 1400  
-600 to 1400  
0 to 65,345  
0 to 65,345  
0 to 65,345  
0 to 65,345  
0 to 65,345  
0 to 65,345  
0 to 65,345  
0 to 65,345  
0
0.1°C  
1400  
Lifetime Avg Temp  
0
Lifetime Max Dsg Current  
Lifetime Max Chg Current  
Lifetime Max Pack Voltage  
Lifetime Min Pack Voltage  
Lifetime Max Cell Voltage  
Lifetime Min Cell Voltage  
Lifetime Max Dsg Power  
Lifetime Max Chg Power  
0
mA  
mV  
0
0
System Data /  
Lifetime Data (59)  
2
20,000  
0
10,000  
10,000  
0
10 mWh  
N/A  
System Data / Lifetime  
Temp Samples (60)  
LT Temp Samples  
0 to 140,000,000  
4
0
CHARGE CONTROL  
CC-CV Charging  
SBS.ChargingCurrent( ) (0x14) Read only, 16-bit unsigned integer word, units in mA. Reports the appropriate  
charging current per the charging algorithm in this section. The default value is set in DF:Fast  
Charge Current, and altered per the algorithm or safety conditions.  
SBS.ChargingVoltage( ) (0x15) Read only, 16-bit unsigned integer word, units in mV. Reports the appropriate  
charging voltage per the charging algorithm in this section. The default value is set in DF:Fast  
Charge Voltage, and altered per the charging algorithm or safety condition.  
SIZE  
(BYTES)  
DEFAULT  
VALUE  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
UNITS  
Fast Charge Current  
Fast Charge Voltage  
Integer  
Integer  
0 to 10000  
0 to 20000  
2
2
mA  
mV  
4000  
Charging / Fast Charge Config. (34)  
16800  
Charge Inhibit Mode  
The bq20z80 sets the SBS.ChargingCurrent( ) and SBS.ChargingVoltage( ) values to 0 to inhibit charging when  
SBS.Temperature( ) < DF:Charge Inhibit Temp Low OR > DF:Charge Inhibit Temp High. When charging is  
inhibited, SBS.ChargingStatus( ) [XCHG] is set.  
If DF:Operation Cfg B [CHGIN] is set, the CHG FET and ZVCHG FET (if used) are turned off when the bq20z80  
is in charge-inhibit mode.  
The bq20z80 allows charging to resume when SBS.Temperature( ) DF:Charge Inhibit Temp Low + DF:Temp  
Hys AND is DF:Charge Inhibit Temp HighDF:Temp Hys. The FETs also return to their previous states at this  
time.  
SBS.ChargingStatus( ) [XCHG] is cleared when these conditions are met, or when a fault condition is detected,  
or when the battery is removed if DF:Operation Cfg B [NR] is cleared.  
57  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
SIZE  
(BYTES)  
DEFAULT  
VALUE  
NAME  
DESCRIPTION  
FORMAT  
VALID RANGE  
UNITS  
Charge Inhibit Temp Low  
Charge Inhibit Temp High  
Temp Hys  
-400 to 1200  
-400 to 1200  
0 to 100  
2
2
1
0
Charge Control / Charge Inhibit Config (32)  
Signed Int  
0.1°C  
450  
10  
Precharge Mode  
The bq20z80 sets SBS.ChargingCurrent( ) to DF:Pre-chg Current when SBS.Temperature( ) is DF:Charge  
Inhibit Temp Low, AND is < DF:Pre-chg Temp, OR if any SBS.CellVoltagex( ) is < DF:Pre-chg Voltage.  
Depending on the setting of DF:Operation Cfg A [ZVCHG1, ZVCHG0] FET action may be taken. Precharge  
mode is also entered if any of SBS.SafetyStatus( ) [ CUV, PUV, OCD or OCD2] are set.  
ZVCHG1  
ZVCHG0  
FET USED  
ZVCHG  
CHG  
0
0
1
1
0
1
0
1
OD Pin  
No Action  
During precharge SBS.Charging Status( ) [PCHG] is set, and is cleared when SBS.Temperature( ) is  
DF:Pre-chg Temp + DF:Temp Hys, AND all SBS.CellVoltagex( ) DF:Recovery Voltage, or Charge Suspend  
is entered, a fault condition detected, or the battery removed if DF:Operation Cfg B [NR] is cleared.  
SIZE  
(BYTES)  
DEFAULT  
VALUE  
NAME  
DESCRIPTION  
FORMAT  
VALID RANGE  
UNITS  
Pre-chg Temp  
Pre-chg Voltage  
Recovery Voltage  
Pre-chg Current  
Signed Int  
-400 to 1200  
0 to 20000  
0 to 20000  
0 to 2000  
0.1°C  
mV  
120  
3000  
3100  
250  
Charge Control / Pre-Charge Config (33)  
2
Integer  
mV  
mA  
Fast Charge  
The bq20z80 sets SBS.ChargingCurrent( ) to DF:Fast Charge Current andSBS.ChargingVoltage( ) to DF:Fast  
Charge Voltage when the following are true.  
SBS.Temperature( ) DF:Pre-chgTemp  
SBS.Temperature( ) < DF:Charge Suspend Temp High - (2 x DF:Delta Temp)  
SBS.CellVoltagex( ) DF:Pre-chg Voltage  
SBS.Voltage( ) SBS.ChargingVoltage( ) + DF:Over Charging Voltage  
See the Charging Faults section for further details. During fast charge, SBS.ChargingStatus( ) [FCHG] is set and  
the CHG FET is turned on if no protection conditions are detected.  
SIZE  
(BYTES)  
DEFAULT  
VALUE  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
UNITS  
Fast Charge Voltage  
Fast Charge Current  
Over Charging Voltage  
0 to 2,0000  
0 to 10,000  
0 to 2000  
2
2
2
mV  
mA  
mV  
16,800  
4000  
500  
Charge Control / Fast Charge Config (34)  
Integer  
Fast Charge Temperature Throttling  
The bq20z80 alters SBS.ChargingCurrent( ) and sets SBS.ChargingStatus( ) [TCHG2, TCHG1] during fast  
charge in response to changing temperature conditions. If SBS.Temperature( ) is DF:Charge Suspend Temp  
High AND is DF:Charge Suspend Temp High - DF:DeltaTemp, then SBS.ChargingCurrent( ) is set to  
DF:Pre-chg Current and SBS.ChargingStatus( ) [TCHG1] is set.  
If SBS.Temeprature( ) is < DF:Charge Suspend Temp High - DF:Delta Temp, AND is DF:Charge Suspend  
Temp High– (2 x DF:DeltaTemp), SBS.ChargingCurrent( ) is set to (DF:Fast Charge Current DF:Pre-chg  
Current) / 2, and SBS.ChargingStatus( ) [TCHG2] is set.  
If SBS.Temperature( ) is < DF:Charge Suspend Temp High– (2 x DF:Delta Temp) AND is DF:Pre-Chg Temp,  
SBS.ChargingCurrent( ) is set to DF:Fast Charge Current, and SBS.ChargingStatus( ) TCHG2, TCHG1] are  
cleared.  
58  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
When transitioning from [FCHG] to [TCHG2] or from [TCHG2] to [TCHG1] the there is additional temperature  
hyteresis of DF:Temp Hys.  
SBS.ChargingStatus( ) [TCHG2, TCHG1] are also cleared when another charging mode is entered, a protection  
condition is detected, or the battery is removed while the DF:Operation Cfg B [NR] is set.  
However, if DF:DeltaTemp is set to 0, SBS.ChargingCurrent( ) remains DF:Fast Charge Current during fast  
charge.  
SIZE  
(BYTES)  
DEFAULT  
VALUE  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
UNITS  
Delta Temp  
Charge Control / Fast Charge Config (34)  
Integer  
0 to 500  
0.1°C  
50  
Charge Suspend Mode  
If charging has begun, the bq20z80 suspends charging when:  
SBS.AverageCurrent( ) is > the DF:Chg Current Threshold, AND  
SBS.Temperature( ) is < DF:Charge Suspend Temp Low AND is > DF:Charge Suspend Temp High.  
If DF:Operation Cfg B [CHGSUSP] is set, the CHG FET and ZVCHG FET (if used), are turned off when the  
bq20z80 is in charge-suspend mode.  
When charging is suspended, SBS.ChargingCurrent( ) is set to 0, and SBS.ChargingStatus( ) [CHGSUSP] is set.  
To return to normal charging, SBS.Temperature( ) must be:  
DF:Charge Inhibit Temp Low + DF:Temp Hys, AND  
DF:Charge Inhibit Temp HighDF:Temp Hys.  
The bq20z80 clears SBS.ChargingStatus(  
)
[CHGSUSP] when this condition is met, and sets  
SBS.ChargingCurrent( ) according to the appropriate charging mode entered. The FETs are also returned to their  
previous state at this time.  
SBS.ChargingStatus( ) [CHGSUSP] is also cleared when a protection condition is detected, or when the battery  
is removed while DF:Operation Cfg B [NR] is cleared.  
SIZE  
(BYTES)  
DEFAULT  
VALUE  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
UNITS  
Charge Suspend Temp Low  
Charge Suspend Temp High  
–400 to 1200  
–400 to 1200  
–50  
550  
Charge Control /  
Fast Charge Config (34)  
Signed Int  
2
0.1°C  
Pulse Charging  
Pulse charging is part of the fast-charging mode and is a loop. During the loop, the measured cell voltages are  
calculated every 250 ms. This data is not reported via the SBS.CellVoltagex( ) commands.  
The pulse-charging loop is entered when the maximum cell voltage is DF:Max OFF Voltage, OR maximum cell  
voltage is DF:Turn OFF Voltage for DF:Max ON Pulse Time. When these conditions are met, the CHG FET is  
turned off, and the SBS.ChargingStatus( ) [PULSE. PULSE_OFF] are set.  
If the maximum cell voltage is < DF:Turn ON Voltage, AND the CHG FET is off for DF:Min OFF Pulse Time, the  
CHG FET is turned on and SBS.ChargingStatus( ) [PULSE_OFF] cleared.  
59  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
bq20z80 Normal  
Charging Mode  
(CHG FET = ON)  
Turn CHG FET on  
Reset t  
Timer  
TERM  
and Start t  
MAX  
Hold  
Timer  
t
CHG_OFF  
No  
Timer  
Turn CHG FET off,  
Yes  
Is V  
Has t  
CELLMAX  
MAX  
Reset t  
CHG_ON  
< V  
?
expired?  
CHG_ON  
Timer  
Yes  
No  
Yes  
No  
No  
Has t  
CHG_ON  
Yes  
Has I  
TERM  
Is V  
CELLMAX  
Yes  
Reset  
expired?  
No  
Been Reached?  
(Normal charge  
termination)  
Has t  
t
> V  
MAX  
?
CHG_OFF  
CHG_OFF  
expired?  
Timer  
No  
Yes  
No  
Is V  
Yes  
Reset and Start  
CELLMAX  
Set Terminate Charge  
Alarm  
t
Timer  
> V  
CHG_OFF  
?
CHG_ON  
Figure 3. Pulse Charging  
The pulse-charging loop is exited and SBS.ChargingStatus( ) [PULSE] is cleared if another charging mode is  
entered, a protection condition detected, or the battery is removed when DF:Operation Cfg B [NR] is cleared.  
SIZE  
(BYTES)  
DEFAULT  
VALUE  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
UNITS  
Turn ON Voltage  
Turn OFF Voltage  
Max ON Pulse Time  
Max OFF Pulse Time  
Max OFF Voltage  
0 to 5000  
0 to 5000  
0 to 240  
0 to 240  
0 to 5000  
4150  
4250  
240  
0
2
mV  
Charge Control /  
Pulse Charge Config (35)  
Integer  
1
2
s/4  
mV  
4270  
Cell Balancing  
The bq20z80 uses the unique ability of Impedance Track™ technology to determine the chemical state of charge  
of each cell. The cell balancing algorithm used in the bq20z80 causes the differences in the cells state of charge  
in the fully charged state to gradually decrease, which prevents high cells from overcharge causing their  
excessive degradation, and increases overall pack energy by preventing too early charge termination. This is  
achieved by calculating the differences in the required amount of charge for each cell from its present state until  
the cell is fully charged. For cells that require less charge to reach full, the difference in charge from those cell  
requiring more charge to reach full (dQ) is by-passed during charging by turning ON bypass FETs in bq29312A  
AFE for a predefined time. When any bypass FET is turned on, then SBS.ChargingStatus( ) [CB] is set;  
otherwise, SBS.ChargingStatus( ) [CB] is cleared.  
Note: If DF:Min Cell Deviation is 0, then no bypass FETs are turned ON and cell balancing is disabled.  
The bypass time needed for each cell is calculated as  
Bypass time = dQ x R / (V x duty_cycle).  
Where, R is the value of the bypass resistance that can be calculated by adding the internal bypass FET resistor  
value of 500 (typ) to the two series input filter resistors (Rχ) of bq29312A and corresponding cells. For  
example: an input filter Rχ value of 100 , R = 500 +100 x 2 = 700 .  
The value of resistances used is accounted for in DF:Min Cell Deviation with units on s/mAh and is calculated by:  
60  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
DF:Min Cell Deviation = (500 + (2 x Rχ) ) / 0.4*3.6V, giving a default of 1750.  
SIZE  
(BYTES)  
DEFAULT  
VALUE  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
UNITS  
Min Cell Deviation Charge Control / Cell Balancing (37)  
Integer  
0 to 65535  
2
s/mAh  
1750  
Primary Charge Termination  
The bq20z80 determines charge termination when the average SBS.Current( ) during 2 consecutive periods of  
DF:Current Taper Window is < DF:Taper Current AND during the 2 consecutive periods of DF:Current Taper  
Window the accumulated change in capacity must be > 0.25mAh. If DF:TCA_Set = -1 the SBS.BatteryStaus(  
)[TCA] will be set when charge termination is detected. If DF:FC_Set = -1 the SBS.BatteryStaus( )[FC] will be set  
when charge termination is detected. If DF:Operation Cfg B [CHGFET] is set, the CHG FET is also turned off.  
For a valid charge termination to occur SBS.Voltage( )+ DF:Termination Voltage must also be DF:Fast Charge  
Voltage.  
When charge termination is detected and if DF:TCA_Set = -1, SBS.ChargingStatus( ) [MCHG] is set, and  
SBS.ChargingCurrent( ) is set to DF:Maintenance Charge Current.  
If DF:Operation Cfg B [CSYNC] is set then SBS.RemainingCapacity( ) is updated with the value in  
SBS.FullChargeCapacity( ) regardless of the setting of DF:TCA_Set.  
SBS.BatteryStatus( ) [FC] is cleared and SBS.ChargingCurrent( ) is set to the appropriate value for battery  
conditions when SBS.RelativeStateOfCharge( ) is < DF:FC Clear %.  
SBS.BatteryStatus( ) [TCA] is also cleared, and SBS.ChargingCurrent( ) is set to the appropriate value for battery  
conditions when DF:Operation Cfg B [CHGTERM] is set, AND SBS.Current( ) is < DF:Chg Current Threshold for  
two consecutive periods of DF:Current Taper Window.  
SIZE  
(BYTES)  
DEFAULT  
VALUE  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
UNITS  
Maintenance Charge Current  
Taper Current  
0 to 1000  
0 to 1000  
0 to 1000  
0 to 60  
2
2
2
1
0
mA  
250  
300  
40  
Charge Control /  
Termination Config. (36)  
Integer  
Termination Voltage  
Current Taper Window  
mV  
s
Charge Control SMBus Broadcasts  
All broadcasts are enabled by setting DF:Operation Cfg B [BCAST]. If DF:Operation Cfg B [HPE] is set, the  
Master-Mode broadcasts to the Host address have PEC enabled, and if DF:Operation Cfg B [CPE] is set, the  
Master-Mode broadcasts to the Smart-Charger address have PEC enabled.  
If enabled, SBS.ChargingVoltage( ) and SBS.ChargingCurrent( ) is broadcast to the Smart-Charger address  
between every 10 and 60 seconds.  
If enabled, SBS.AlarmWarning( ) is broadcast to the Host address every 10 seconds, only while any of the  
SBS.BatteryStatus( ), bits 8 -15, are set. Broadcasting stops when SBS.BatteryStatus( ), 8-15, are clear.  
If enabled, SBS.AlarmWarning( ) is broadcast to the Smart Charger address every 10 seconds only when any of  
SBS.BatteryStatus( ), bits 11 -15. Broadcasting stops when SBS.BatteryStatus( ), 11-15, are clear.  
Charging Faults  
Charge Fault Cfg  
CHARGE FAULT Fault  
CONFIGURATION  
bit7  
bit6  
bit5  
bit4  
bit3  
bit2  
bi1  
bit0  
Low Byte  
PCMTO  
FCMTO  
OCHGV  
OCHGI  
OC  
XCHGLV  
61  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
The DF:Charge Fault Cfg bits enable FET action to take place when a fault occurs. See the following details  
within this section for selecting the appropriate settings.  
Battery Depleted  
The bq20z80 sets SBS.ChargingStatus( ) [XCHGLV] when the charger is present AND SBS.Voltage( ) is  
DF:Depleted Voltage for period DF:Depleted Voltage Time.  
When this fault is detected, SBS.ChargingCurrent( ) is set to 0, SBS.BatteryStatus( ) [TDA] is set and if  
DF:Charge Fault Cfg [XCHGLV] is set then the DSG FET is turned off and the CHG and ZVCHG FETs controlled  
per the configuration of DF:Operation Cfg A [ZVCHG1, ZVCHG0].  
To recover from this mode SBS.Voltage( ) must become DF:Depleted Recovery. When the bq20z80 recovers  
from a Battery Depleted state, the DSG, CHG, and ZVCHG FETs are returned to the previous state in  
accordance with the charging algorithm and DF:Operation Cfg, A [ZVCHG1, ZVCHG0] and SBS.BatteryStatus( )  
[TCA] and SBS.ChargingStatus( ) [XCHGLV] are reset.  
SIZE  
(BYTES)  
DEFAULT  
VALUE  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
UNITS  
Depleted Voltage  
Depleted Voltage Time  
Depleted Recovery  
0 to 16,000  
0 to 60  
2
1
2
mV  
s
8000  
2
Charging Control /  
Charging Faults (38)  
Integer  
0 to 16,000  
mV  
8500  
Overcharging Voltage  
The bq20z80 sets SBS.ChargingStatus( ) [OCHGV] when SBS.Voltage( ) SBS.ChargingVoltage( ) + DF:Over  
Charging Voltage for a period DF:Over Charging Volt Time . If DF:Over Charging Volt Time = 0, this feature is  
completely disabled.  
When DF:Charge Fault Cfg [OCHGV] is set, then the CHG and ZVCHG FETs are turned off. Also,  
SBS.ChargingCurrent( ) and SBS.ChargingVoltage( ) are cleared to 0, and SBS.BatteryStatus( ) [TCA] is set.  
To recover from this mode, SBS.Voltage( ) must become DF:Fast Charge Voltage. When the bq20z80 recovers  
from an Overcharging Voltage state, the CHG and ZVCHG FETs are returned to the previous state in  
accordance with the charging algorithm, and SBS.BatteryStatus( ) [TCA] is reset. SBS.ChargingCurrent( )  
[OCHGV] and SBS.ChargingVoltage( ) are not reset via this recovery.  
If SBS.Voltage( ) SBS.ChargingVoltage( ) then SBS.ChargingCurrent( ), SBS.ChargingVoltage( ), and the CHG  
and ZVCHG FETs are returned to the previous state in accordance with the charging algorithm, and  
DF:Operation Cfg A [ZVCHG1, ZVCHG0] and SBS.BatteryStatus( ) [TCA] are reset.  
SIZE  
(BYTES)  
DEFAULT  
VALUE  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
UNITS  
Over Charging Voltage  
Over Charging Volt Time  
Integer  
Integer  
0 to 3000  
0 to 60  
2
1
mV  
s
500  
2
Charging Control /  
Charging Faults (38)  
Overcharging Current  
The bq20z80 sets SBS.ChargingStatus( ) [OCHGI] when SBS.Current( ) is SBS.ChargingCurrent( ) + DF:Over  
Charging Current for a period of DF:Over Charging Curr Time. If DF:Over Charging Curr Time = 0, then feature  
is completely disabled.  
When DF:Charge Fault Cfg [XOCHGI] is set, then the CHG FET is turned OFF and ZVCHG FET is turned ON if  
DF:Operation Cfg  
A [ZVCHG1, ZVCHG0] are set appropriately. Also, SBS.ChargingCurrent( ) and  
SBS.ChargingVoltage( ) are cleared to 0, and SBS.BatteryStatus( ) [TCA] is set.  
To recover from this mode, SBS.AverageCurrent( ) must be DF:Over Charging Curr Recov . When the  
bq20z80 recovers from an Overcharging Current state, then SBS.ChargingCurrent( ), SBS.ChargingVoltage( ),  
and the CHG and ZVCHG FE's are returned to previous state in accordance with the charging algorithm and  
DF:Operation Cfg A [ZVCHG1, ZVCHG0]. SBS.BatteryStatus( ) [TCA] and SBS.ChargingStatus( ) [OCHGI] are  
cleared.  
62  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
VALID  
RANGE  
SIZE  
(BYTES)  
DEFAULT  
VALUE  
NAME  
CLASS / SUBCLASS  
FORMAT  
UNITS  
Over Charging Current  
Over Charging Curr Time  
Over Charging Curr Recov  
0 to 2000  
0 to 60  
2
1
2
mA  
s
500  
2
Charging Control /  
Charging Faults (38)  
Integer  
0 to 2000  
mA  
100  
Overcharge  
The bq20z80 sets SBS.ChargingStatus( ) [OC] when the amount of capacity added after the point where  
SBS.RemainingCapacity( ) is > SBS.FullChargeCapacity( ) + DF:Over Charge Capacity. If DF:Over Charge  
Capacity is set to 0, this feature is completely disabled.  
When DF:Charge Fault Cfg [XOCHG] is set, then the CHG FET and ZVCHG FET are turned off if DF:Operation  
Cfg A [ZVCHG1, ZVCHG0] are set appropriately. Also, SBS.ChargingCurrent( ) and SBS.ChargingVoltage( ) are  
set to 0, and SBS.BatteryStatus( ) [TCA, OCA] are set.  
There are three recovery methods from this fault state:  
1. If DF:Operation Cfg B [NR] = 0, AND a transition input of PRES from low-to-high-to-low (pack removal and  
re-insertion) occurs, the bq20z80 recovers from this fault mode.  
2. If DF:Operation Cfg B [NR] = 1 AND SBS.Current( ) is 0 mA, AND there has been DF:Over Charge  
Recovery amount of continuous discharge, the bq20z80 recovers from this fault mode.  
3. If SBS.RemainingStateOfCharge%( ) becomes DF:FC Clear %, the bq20z80 recovers from this fault  
mode.  
On recovery, the CHG and ZVCHG FETs are returned to the previous state in accordance with the charging  
algorithm, and DF:Operation Cfg A [ZVCHG1, ZVCHG0]. SBS.BatteryStatus( ) [TCA, FC, OCA], and  
SBS.ChargingStatus( ) [OC] are cleared.  
VALID  
RANGE  
SIZE  
(BYTES)  
DEFAULT  
VALUE  
NAME  
CLASS / SUBCLASS  
FORMAT  
UNITS  
Over Charge Capacity  
Over Charge Recovery  
0 to 4000  
0 to 1000  
2
2
300  
2
Charging Control /  
Charging Faults (38)  
Integer  
mAh  
Fast Charge Mode Charging Timeout  
When SBS.Current( ) is DF:Chg Current Threshold, the bq20z80 starts the Fast Charge timer.  
The Fast Charge Timer is suspended when SBS.ChargingStatus( ) [PULSEOFF] = 1 or SBS.ChargingStatus( )  
[FCHG] = 0, or when SBS.BatteryStatus( ) [DSG] = 1, or when the fast charge timer expires.  
The Fast Charge Timer is reset when DF:Over Charge Recovery amount of discharge is detected, OR if  
DF:Operation Cfg B [NR] = 1, AND PRES transitions from low-to-high-to-low.  
The bq20z80 sets SBS.ChargingStatus( ) [FCMTO] if the fast charge timer DF:FC-MTO, then if DF:Charge  
Fault Cfg [XFCMTO] is set, then the CHG FET is turned off, and the ZVCHG FET is turned OFF if DF:Operation  
Cfg A [ZVCGH1, ZVCHG0] are set appropriately. Also, SBS.ChargingCurrent( ) and SBS.ChargingVoltage( ) are  
set to 0, and SBS.BatteryStatus( ) [TCA] is set. If DF:FC-MTO is programmed to 0, this feature is completely  
disabled.  
To recover from this mode,SBS.Current( ) must be (-) DF:Dsg Current Threshold or if DF:Operation Cfg B  
[NR] = 0 AND PRES transitions from low-to-high-to-low. On recovery, the SBS.ChargingCurrent( ),  
SBS.ChargingVoltage( ) and the CHG and ZVCHG FETs are returned to the previous state in accordance with  
the charging algorithm, and DF:Operation Cfg A [ZVCHG1, ZVCHG0]. SBS.BatteryStatus( ) [TCA], and  
SBS.ChargingStatus( ) [FCMTO] are cleared.  
SIZE  
(BYTES)  
DEFAULT  
VALUE  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
UNITS  
FC-MTO  
Charging Control / Charging Faults (38)  
Integer  
0 to 65535  
2
s
10800  
Precharge Mode Charging Timeout  
When SBS.Current( ) is DF:Chg Current Threshold the bq20z80 starts the Precharge Timer.  
The Precharge Timer is suspended when pulse charging is active (SBS.ChargingStatus( ) [PULSEOFF] = 1), and  
when SBS.ChargingStatus( ) [PCHG] = 0).  
63  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
The bq20z80 sets SBS.ChargingStatus( ) [PCMTO] if the Pre-Charge Timer DF:PC-MTO, and if DF:Charge  
Fault Cfg [XPCMTO] is set, then the CHG FET is turned off, and the ZVCHG FET is turned off if DF:Operation  
Cfg A [ZVCHG1, ZVCHG0] are set appropriately. Also, SBS.ChargingCurrent( ) and SBS.ChargingVoltage( ) are  
set to 0, and SBS.BatteryStatus( ) [TCA] is set. If DF:PC-MTO is programmed to 0, this feature is completely  
disabled.  
To recover from this mode, SBS.Current( ) must be (-) DF:Dsg Current Threshold, or if DF:Operation Cfg B  
[NR] = 0 AND PRES transitions from low-to-high-to-low. On recovery, the SBS.ChargingCurrent( ),  
SBS.ChargingVoltage( ) and the CHG and ZVCHG FETs are returned to the previous state in accordance with  
the charging algorithm, SBS.BatteryStatus( ) [TCA] and SBS.ChargingStatus( ) [PCMTO] are cleared.  
SIZE  
(BYTES)  
DEFAULT  
VALUE  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
UNITS  
PC-MTO  
Charging Control / Charging Faults (38)  
Integer  
0 to 65,535  
2
s
3600  
POWER MODE  
The bq20z80 has several power modes. During these modes, the bq20z80 modifies its operation to minimize  
power consumption from the battery.  
During normal operation, the bq20z80 takes ADC.Current, ADC.Voltage, and ADC.Temperature measurements,  
performs calculations, updates SBS data, and makes protection and status decisions at one-second intervals.  
Between these periods of activity, the bq20z80 is in a reduced power state.  
PRES is detected during the measurement period, where the PU pin is pulled high, the PRES input state is read,  
and PU is released. If PRES is high, SBS.OperationStatus( ) [PRES] is cleared. If PRES is low,  
SBS.OperationStatus( ) [PRES] is set indicating the system is present (the battery is inserted).  
If DF:Operation Cfg B [NR] is set, the PRES input can be left floating as it is not monitored.  
Normal Mode Discharge Fault – Current  
The bq20z80 reports a Normal Mode Discharge fault due to Current by setting SBS.OperationStatus( ) [XDSGI]  
any SBS.SafetyStatus(  
) [OCD, OCD2, AOCD, ASCD] is set. Also, SBS.ChargingCurrent( ) and  
SBS.BatteryStatus( ) [TCA] are changed according to SBS.SafetyStatus( ) flag.  
When all of SBS.SafetyStatus( ) [OCD, OCD2, AOCD, ASCD] are cleared, SBS.BatteryStatus( ) [TDA] and  
SBS.OperationStatus( ) [XDSGI] are also cleared.  
Sleep Mode  
In Sleep mode, the bq20z80 measures ADC.Voltage and ADC.Temperature every DF:Sleep Voltage Time  
interval, and ADC.Current is measured at intervals of DF:Sleep Current Time. At each interval, the bq20z80  
performs calculations, updates SBS data and makes protection and status decisions. Between these periods of  
activity, the bq20z80 is in a reduced-power state.  
The bq20z80 enters Sleep mode when the following conditions exist.  
SBS.Current( ) in charge or discharge is DF:Sleep Current, AND SMBus is Low for DF:Bus Low Time,  
AND DF:Operation Cfg A [SLEEP] is set  
OR  
SBS.Current( ) is DF:Sleep Current in discharge, AND SBS.ManufacturerAccess( ) Sleep command is  
received, AND DF:Operation Cfg A [SLEEP] is set.  
AND  
If DF:Operation Cfg B [NR] is cleared, the PRES input must also be high, SBS.OperationStatus( ) [PRES] =  
0, for the bq20z80 to enter sleep.  
Entry to Sleep mode is blocked if any of SBS.SafetyStatus( ) [OCD, OCC, OCD2, OCC2, PF, AOCD, ASCC,  
ASCD] are set, or if any protection-feature recovery timers are active and have not expired, or if DF:Sleep  
Voltage Time =0 or DF:Sleep Current Time = 0, sleep mode is not entered, and the bq20z80 remains in Normal  
mode.  
64  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
On entry to sleep, and if DF:Operation Cfg B [NR] is cleared, the CHG and DSG FETs are turned off, and the  
ZVCHG FET is turned off if DF:Operation Cfg A [ZVCHG1, ZVCHG0] are set appropriately. If DF:Operation Cfg  
B [NR] is set, the CHG FET is turned off, and the ZVCHG FET is turned off if DF:Operation Cfg A [ ZVCHG1,  
ZVCHG0] are set appropriately. However, if DF:Operation Cfg B [NRCHG] is set then the CHG remains on.  
Also, on entry to Sleep mode, the auto calibration of the ADC begins. However, if SBS.Temperature( )  
is DF:Cal Inhibit Temp Low and DF:Cal Inhibit Temp High, Auto Calibration of the ADC is not started on  
entry to sleep mode. The activation of auto calibration is not affected by the state of DF:Operation Cfg A  
[SLEEP], nor DF:Sleep Voltage Time, nore DF:Sleep Current Time nor SBS.Current( ).  
The bq20z80 exits Sleep mode if |SBS.Current( )| is nonzero, OR the SMBC or the SMBD input transitions high,  
OR any SBS.OperationStatus( ), SBS.ChargingStatus( ), or SBS.SafetyStatus( ) flags change state.  
If DF:Operation Cfg B [NR] is cleared, the bq20z80 exits Sleep mode when PRES is pulled low  
(SBS.OperationStatus( ) [PRES] = 1).  
SIZE  
(BYTES)  
DEFAULT  
VALUE  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
UNITS  
Sleep Current  
Sleep Voltage Time  
Sleep Current Time  
Bus Low Time  
0 to 100  
0 to 100  
1
1
1
1
2
2
mA  
10  
5
s
s
Integer  
0 to 255  
20  
5
Power / Power (68)  
0 to 255  
s
Cal Inhibit Temp High  
Cal Inhibit Temp Low  
-400 to 1200  
-400 to 1200  
0.1°C  
0.1°C  
50  
450  
Signed Int  
Battery Removed Mode  
The bq20z80 detects the Battery-Removed state when DF:Operation Cfg B [NR] is cleared AND the PRES input  
is high (SBS.Operation Status( ) [PRES] = 0).  
On entry to Battery-Removed state, SBS.BatteryStatus( ) [TCA, TDA] are set, SBS.ChargingCurrent( ) and  
SBS.ChargingVoltage( ) are set to 0, and the CHG and DSG FETs are turned off, and the ZVCHG FET is turned  
off if DF:Operation Cfg A [ZVCHG1, ZVCGH0] are set appropriately.  
Polling of the PRES pin continues at a rate of once every 1 s.  
The bq20z80 exits the Battery-Removed state if DF:Operation Cfg B [NR] is cleared, AND the PRES input is low  
(SBS.OperationStatus( ) [PRES] = 1). When this occurs, SBS.BatteryStatus( ) [TCA, TDA] are reset.  
Shutdown Mode  
The bq20z80 enters Shutdown mode if the following conditions are met:  
SBS.Voltage( ) DF:Shutdown Voltage AND SBS.Current( )0  
OR  
(SBS.ManufacturerAccess( ) shutdown command received AND SBS.Current( ) = 0) AND Voltage at the  
bq29312A Pack pin < DF:Charger Present threshold.  
If DF:Operation Cfg B [NR], is set, DF:Charger Present must be > DF:Shutdown Voltage + 6% for correct  
operation.  
It is also recommended that the value of DF:Charger Present be > 4.3 V x the number of series cells regardless  
of the setting of DF:Operation Cfg B [NR].  
When the bq20z80 meets these conditions, the CHG, DSG, and ZVCHG FETs are turned off, and the bq29312A  
is commanded to shut down. In Shutdown mode, the bq20z80 is completely powered down because its supply is  
removed.  
To exit Shutdown mode, the voltage at the PACK pin of the bq29312A must be greater than its minimum  
operating voltage. When this occurs, the bq29312A returns power to the bq20z80, SBS.OperationStatus( )  
[WAKE] is set and the bq29312A configured. The SBS.BatteryMode( ) [INIT] and SBS.OperationStatus( )  
[WAKE] are cleared after approximately 1 s when all SBS parameters have been measured and updated.  
65  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
SIZE  
(BYTES)  
DEFAULT  
VALUE  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
UNITS  
Shutdown Voltage  
Shutdown Time  
Charger Present  
5000 to 20000  
0 to 60  
2
1
2
mV  
s
7000  
10  
Power / Power (68)  
Integer  
0 to 23000  
mV  
16800  
Display  
Configuration  
Number of LEDs Supported  
DF:Operation Cfg A [LED1, LED0] determine the number of LEDs supported.  
LED1  
LED0  
LEDs SUPPORTED  
0
0
1
1
0
1
0
1
User(1)  
3
4
5
(1) When User configuration selected, the LEDs are controlled as shown in the Display Format tables.  
NOTE:  
At power up, DF:Operation Cfg A [LED1, LED0] are read, the associated DSG Thresh  
x and CHG Thresh x thresholds are set per the tables in the Display Format -  
Discharge and Display Format - Charge sections.  
Display Type  
If DF:Operation Cfg A [SLED] = 0, then the LEDs are controlled as a parallel configuration display. However, if  
DF:Operation Cfg A [SLED] = 1, then the LEDs are controlled as a series-configuration display and the  
permanent failure display is disabled.  
The serial LED option can be used to implement a much brighter display at the expense of additional hardware  
components. With the normal connection, the 3.3 V output from the bq29312A is used to power the LEDs. Using  
that approach, current in each LED should be limited to 3 mA maximum. With the serial option (DF:Operation Cfg  
A [SLED] = 1), all LEDs can be powered from the battery voltage and driven in series through a simple constant  
current regulator. The current is then diverted to ground at the various nodes between the series LEDs in order  
to program the desired pattern.  
Display Mode  
The mode of the display is set in DF:Operation Cfg A [DMODE].  
DMODE  
LEDs SUPPORTED  
Relative Mode (default)  
Absolute Mode  
% DATA  
FULL REFERENCE  
SBS.DesignCapacity( )  
SBS.FullChargeCapacity( )  
0
1
SBS.RelativeStateOfCharge( )  
SBS.AbsoluteStateOfCharge( )  
66  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
Display Format - Discharge  
This mode is available when SBS.BatteryStatus( ) [DSG] = 1  
LED  
THRESHOLD  
3-LEDs  
10%  
4-LEDs  
10%  
5-LEDs  
10%  
USER  
ALARM  
DSG FLASH ALARM  
DSG FLASH ALARM  
1
2
3
4
5
SBS.RSOC%( )DSG Thresh 1  
SBS.RSOC%( )DSG Thresh 2  
SBS.RSOC%( )DSG Thresh 3  
SBS.RSOC%( )DSG Thresh 4  
SBS.RSOC%( )DSG Thresh 5  
0 to 33%  
34 to 66%  
67 to 100%  
0 to 24%  
25 to 49%  
50 to 74%  
75 to 100%  
0 to 19%  
20 to 39%  
40 to 59%  
60 to 79%  
80 to 100%  
SBS.RSOC%( ) DF:DSG Thresh 1  
SBS.RSOC%( ) DF:DSG Thresh 2  
SBS.RSOC%( ) DF:DSG Thresh 3  
SBS.RSOC%( ) DF:DSG Thresh 4  
SBS.RSOC%( ) DF:DSG Thresh 5  
The DSG Thresh x threshold is the % of SBS.RelativeStateOfCharge( ) or SBS.AbsoluteStateOfCharge( ) to  
enable the respective LED.  
The DSG Flash Alarm threshold is the % of SBS.RelativeStateOfCharge( ) or SBS.AbsoluteStateOfCharge( ) at  
which the remaining active LEDs flash at a 50% duty-cycle rate of DF:LED Flash Rate.  
If DF:Operation Cfg A [LEDRCA] AND SBS.BatteryStatus( ) [RCA] are set, the display flashes at the DF:LED  
Flash Rate with a 50% duty cycle.  
If DF:Operation Cfg A [LED1, LED0] = User, the User data flash percentages are used and the values are  
defined within the range indicated in the Display Timing table.  
When DF:Operation Cfg A [LEDRCA] = 0, the SBS.BatteryStatus( )[RCA] is ignored.  
Display Format - Charge  
This mode is available when SBS.BatteryStatus( ) DSG = 0  
LED  
THRESHOLD  
3-LEDs  
10%  
4-LEDs  
10%  
5-LEDs  
10%  
USER  
ALARM  
CHG Flash Alarm  
CHG Flash Alarm  
1
2
3
4
5
SBS.RSOC%( )CHG Thresh 1  
SBS.RSOC%( )CHG Thresh 2  
0 to 33%  
34 to 66%  
0 to 24%  
25 to 49%  
50 to 74%  
75 to 100%  
0 to 19%  
20 to 39%  
40 to 59%  
60 to 79%  
80 to 100%  
SBS.RSOC%( )DF:CHG Thresh 1  
SBS.RSOC%( )DF:CHG Thresh 2  
SBS.RSOC%( )DF:CHG Thresh 3  
SBS.RSOC%( )DF:CHG Thresh 4  
SBS.RSOC%( )DF:CHG Thresh 5  
SBS.RSOC%( )CHG Thresh 3 67 to 100%  
SBS.RSOC%( )CHG Thresh 4  
SBS.RSOC%( )CHG Thresh 5  
The CHG Thresh x threshold is the % of SBS.RelativeStateOfCharge( ) or SBS.AbsoluteStateOfCharge( ) to  
enable the respective LED.  
During charging the top LED segment flashs at the rate or DF:LED Blink Rate (eg: if  
SBS.RelativeStateOfCharge( ) = 36% and 5 LEDs are being used then LED2 will blink).  
The CHG Flash Alarm threshold is the % of SBS.RelativeStateOfCharge( ) or SBS.AbsoluteStateOfCharge( ) at  
which the remaining active LEDs flash at the rate of DF:LED Flash Rate, with a 50% duty cycle.  
If DF:Operation Cfg A [LEDRCA] AND SBS.BatteryStatus( ) [RCA] are set, the display flashes at the DF:LED  
Flash Rate with a 50% duty cycle.  
If DF:Operation Cfg A [LED1, LED0] = user, the user data flash percentages are used and the values are defined  
within the range indicated in the Display Timing table.  
67  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
Display Format - Permanent Failure  
This mode is available when SBS.SafetyStatus( ) [PF] = 1. The LEDs indicate the permanent failure cause as  
indicated by the flag in SBS.PFStatus( ) and by illuminating LED1 at the DF:LED Flash Rate with a 50% duty  
cycle.  
SBS.PFStatus( )  
No PF Fault  
PFIN  
LED3  
Blink  
Blink  
Blink  
Blink  
Blink  
Blink  
Blink  
Blink  
Blink  
0
LED2  
0
LED1  
0
1
0
SOV  
Flash  
0
0
SOTC  
1
SOTD  
1
1
CIM  
Flash  
0
1
Flash  
Flash  
Flash  
0
CFETF  
DFETF  
DFF  
1
Flash  
Blink  
Blink  
Blink  
Blink  
Blink  
Blink  
Blink  
Blink  
AFE_C  
AFE_P  
SOCC  
SOCD  
SOPT  
1
0
Flash  
0
0
1
1
1
RSVD  
Flash  
0
1
RSVD  
Flash  
Flash  
FBF  
1
68  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
Display Timing  
When the display is activated, between each active LED illumination there is a delay time of DF:LED Delay.  
When all active LEDs are illuminated, the display remains active for DF:LED Hold time. When this time expires,  
all LEDs turn off at the same time.  
SIZE  
(BYTES)  
DEFAULT  
VALUE  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
UNITS  
LED Flash Rate  
LED Blink Rate  
LED Delay  
500  
1000  
100  
4
1 to 65535  
0 to 255  
2
ms  
s
LED Hold Time  
CHG Thresh 1  
CHG Thresh 2  
CHG Thresh 3  
CHG Thresh 4  
CHG Thresh 5  
DSG Thresh 1  
DSG Thresh 2  
DSG Thresh 3  
DSG Thresh 4  
DSG Thresh 5  
CHG Flash Alarm  
DSG Flash Alarm  
0
20  
40  
60  
80  
0
LED Support / LED Cfg (67)  
Signed Int  
1
0 to 101  
%
20  
40  
60  
80  
10  
10  
Display Activation  
There are 4 methods of display activation.  
1. SBS.ManufacturerAcces( ) commands – See the SBS.ManufacturerAccess( ) section for details.  
2. If DF:Operation Cfg A [LEDR] is set, the display is activated on exit from reset.  
3. If DF:Operation Cfg A [CHGLED] is set, while SBS.Current( ) is > DF:Chg Current Threshold, the display  
remains active.  
4. High-to-low logic transition on the DISP pin. The next high-to-low transition of DISP is not recognized until  
DF:LED Hold expires.  
If DF:Operation Cfg B [PFD0] is set, then the Permanent Failure (PF) display can be activated for a further period  
of 2 x DF:LED Hold per each bit set in SBS.PFStatus( ) in two possible ways depending on DF:Operation Cfg B  
[PFD1]. The PF display is shown after the normal capacity display.  
1. If a high-to-low logic transition on the DISP pin occurs, AND the low-state is held for DF:LED Hold, AND  
DF:Operation Cfg B [PFD1] = 0  
2. If a high-to-low logic transition on the DISP pin occurs, AND DF:Operation Cfg B [PFD1] = 1.  
The display is disabled if either of SBS.SafetyStatus( ) [CUV, PUV] are set.  
Application Schematic  
69  
2
DSG  
21  
ZVCHG  
20  
CHG  
1
BAT  
22  
18  
17  
PACK  
19  
3
SLEEP  
VC1  
REG  
TOUT  
U2  
24  
13  
bq29312  
OD  
4
5
6
VC2  
VC3  
VC4  
SCLK  
14  
SDATA  
16  
10  
11  
XALERT  
WDI  
7
VC5  
23  
PMS  
CELL  
SR1 SR2  
GND GND  
15  
12  
8
9
04-26-05  
DW  
PACKAGE OPTION ADDENDUM  
www.ti.com  
8-Aug-2005  
PACKAGING INFORMATION  
Orderable Device  
BQ20Z80DBT  
Status (1)  
ACTIVE  
ACTIVE  
ACTIVE  
ACTIVE  
ACTIVE  
ACTIVE  
Package Package  
Pins Package Eco Plan (2) Lead/Ball Finish MSL Peak Temp (3)  
Qty  
Type  
Drawing  
SM8  
DBT  
38  
38  
38  
38  
38  
38  
50 Green (RoHS & CU NIPDAU Level-2-260C-1 YEAR  
no Sb/Br)  
BQ20Z80DBT-V101  
BQ20Z80DBT-V101G4  
BQ20Z80DBTR  
SM8  
SM8  
SM8  
SM8  
SM8  
DBT  
DBT  
DBT  
DBT  
DBT  
50 Green (RoHS & CU NIPDAU Level-2-260C-1 YEAR  
no Sb/Br)  
50 Green (RoHS & CU NIPDAU Level-2-260C-1 YEAR  
no Sb/Br)  
2000 Green (RoHS & CU NIPDAU Level-2-260C-1 YEAR  
no Sb/Br)  
BQ20Z80DBTR-V101  
BQ20Z80DBTR-V101G4  
2000 Green (RoHS & CU NIPDAU Level-2-260C-1 YEAR  
no Sb/Br)  
2000 Green (RoHS & CU NIPDAU Level-2-260C-1 YEAR  
no Sb/Br)  
(1) The marketing status values are defined as follows:  
ACTIVE: Product device recommended for new designs.  
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.  
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in  
a new design.  
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.  
OBSOLETE: TI has discontinued the production of the device.  
(2)  
Eco Plan  
-
The planned eco-friendly classification: Pb-Free (RoHS) or Green (RoHS  
&
no Sb/Br)  
-
please check  
http://www.ti.com/productcontent for the latest availability information and additional product content details.  
TBD: The Pb-Free/Green conversion plan has not been defined.  
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements  
for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered  
at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.  
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame  
retardants (Br or Sb do not exceed 0.1% by weight in homogeneous material)  
(3)  
MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder  
temperature.  
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is  
provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the  
accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take  
reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on  
incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited  
information may not be available for release.  
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI  
to Customer on an annual basis.  
Addendum-Page 1  
IMPORTANT NOTICE  
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications,  
enhancements, improvements, and other changes to its products and services at any time and to discontinue  
any product or service without notice. Customers should obtain the latest relevant information before placing  
orders and should verify that such information is current and complete. All products are sold subject to TI’s terms  
and conditions of sale supplied at the time of order acknowledgment.  
TI warrants performance of its hardware products to the specifications applicable at the time of sale in  
accordance with TI’s standard warranty. Testing and other quality control techniques are used to the extent TI  
deems necessary to support this warranty. Except where mandated by government requirements, testing of all  
parameters of each product is not necessarily performed.  
TI assumes no liability for applications assistance or customer product design. Customers are responsible for  
their products and applications using TI components. To minimize the risks associated with customer products  
and applications, customers should provide adequate design and operating safeguards.  
TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right,  
copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process  
in which TI products or services are used. Information published by TI regarding third-party products or services  
does not constitute a license from TI to use such products or services or a warranty or endorsement thereof.  
Use of such information may require a license from a third party under the patents or other intellectual property  
of the third party, or a license from TI under the patents or other intellectual property of TI.  
Reproduction of information in TI data books or data sheets is permissible only if reproduction is without  
alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction  
of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for  
such altered documentation.  
Resale of TI products or services with statements different from or beyond the parameters stated by TI for that  
product or service voids all express and any implied warranties for the associated TI product or service and  
is an unfair and deceptive business practice. TI is not responsible or liable for any such statements.  
Following are URLs where you can obtain information on other Texas Instruments products and application  
solutions:  
Products  
Applications  
Audio  
Amplifiers  
amplifier.ti.com  
www.ti.com/audio  
Data Converters  
dataconverter.ti.com  
Automotive  
www.ti.com/automotive  
DSP  
dsp.ti.com  
Broadband  
Digital Control  
Military  
www.ti.com/broadband  
www.ti.com/digitalcontrol  
www.ti.com/military  
Interface  
Logic  
interface.ti.com  
logic.ti.com  
Power Mgmt  
Microcontrollers  
power.ti.com  
Optical Networking  
Security  
www.ti.com/opticalnetwork  
www.ti.com/security  
www.ti.com/telephony  
www.ti.com/video  
microcontroller.ti.com  
Telephony  
Video & Imaging  
Wireless  
www.ti.com/wireless  
Mailing Address:  
Texas Instruments  
Post Office Box 655303 Dallas, Texas 75265  
Copyright 2005, Texas Instruments Incorporated  

相关型号:

BQ20Z80DBT-V101

SBS 1.1-COMPLIANT GAS GAUGE ENABLED WITH IMPEDANCE TRACK TECHNOLOGY FOR USE WITH THE bq29312A
TI

BQ20Z80DBT-V101G4

SBS 1.1-COMPLIANT GAS GAUGE ENABLED WITH IMPEDANCE TRACK TECHNOLOGY FOR USE WITH THE bq29312A
TI

BQ20Z80DBT-V102

SBS 1.1-COMPLIANT GAS GAUGE ENABLED WITH IMPEDANCE TRACK TM TECHNOLOGY FOR USE WITH THE BQ29312A
TI

BQ20Z80DBT-V110

SBS 1.1-COMPLIANT GAS GAUGE ENABLED WITH IMPEDANCE TRACK⑩ TECHNOLOGY FOR USE WITH THE bq29312A
TI

BQ20Z80DBT-V110G4

SBS 1.1-COMPLIANT GAS GAUGE ENABLED WITH IMPEDANCE TRACK
TI

BQ20Z80DBTG4

SBS 1.1-COMPLIANT GAS GAUGE ENABLED WITH IMPEDANCE TRACK⑩ TECHNOLOGY FOR USE WITH THE bq29312A
TI

BQ20Z80DBTR

SBS 1.1-COMPLIANT GAS GAUGE ENABLED WITH IMPEDANCE TRACK TECHNOLOGY FOR USE WITH THE bq29312A
TI

BQ20Z80DBTR-V101

SBS 1.1-COMPLIANT GAS GAUGE ENABLED WITH IMPEDANCE TRACK TECHNOLOGY FOR USE WITH THE bq29312A
TI

BQ20Z80DBTR-V101G4

SBS 1.1-COMPLIANT GAS GAUGE ENABLED WITH IMPEDANCE TRACK TECHNOLOGY FOR USE WITH THE bq29312A
TI

BQ20Z80DBTR-V102

SBS 1.1-COMPLIANT GAS GAUGE ENABLED WITH IMPEDANCE TRACK TM TECHNOLOGY FOR USE WITH THE BQ29312A
TI

BQ20Z80DBTR-V102G4

SBS 1.1-COMPLIANT GAS GAUGE ENABLED WITH IMPEDANCE TRACK TM TECHNOLOGY FOR USE WITH THE BQ29312A
TI

BQ20Z80DBTR-V110

SBS 1.1-COMPLIANT GAS GAUGE ENABLED WITH IMPEDANCE TRACK⑩ TECHNOLOGY FOR USE WITH THE bq29312A
TI