CD74ACT32-Q1 [TI]
QUADRUPLE 2-INPUT POSITIVE-OR GATE; 四路2输入正或门型号: | CD74ACT32-Q1 |
厂家: | TEXAS INSTRUMENTS |
描述: | QUADRUPLE 2-INPUT POSITIVE-OR GATE |
文件: | 总9页 (文件大小:200K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
CD74ACT32-Q1
QUADRUPLE 2-INPUT POSITIVE-OR GATE
SCHS351A − JANUARY 2004 − REVISED JANUARY 2008
M PACKAGE
(TOP VIEW)
D
D
D
D
Qualified for Automotive Applications
Inputs Are TTL-Voltage Compatible
Buffered Inputs
1A
1B
1Y
2A
2B
1
2
3
4
5
6
7
14 VCC
13
12
11
10
9
4B
4A
4Y
3B
3A
3Y
Speed of Bipolar F, AS, and S, With
Significantly Reduced Power Consumption
D
Balanced Propagation Delays
D
24-mA Output Drive Current
− Fanout to 15 F Devices
2Y
GND
8
D
SCR-Latchup-Resistant CMOS Process and
Circuit Design
description/ordering information
The CD74ACT32 is a quadruple 2-input positive-OR gate. This device performs the Boolean function
Y + A • B or Y + A ) B in positive logic.
ORDERING INFORMATION†
ORDERABLE
PART NUMBER
TOP-SIDE
MARKING
‡
T
A
PACKAGE
−40°C to 125°C
SOIC − M
Tape and reel CD74ACT32QM96Q1
ACT32Q
†
‡
For the most current package and ordering information, see the Package Option Addendum at the end of
this document, or see the TI web site at http://www.ti.com.
Package drawings, thermal data, and symbolization are available at http://www.ti.com/packaging.
FUNCTION TABLE
(each gate)
INPUTS
OUTPUT
Y
A
B
X
H
L
H
X
L
H
H
L
logic diagram (positive logic)
A
B
Y
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
Copyright 2008, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
1
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
CD74ACT32-Q1
QUADRUPLE 2-INPUT POSITIVE-OR GATE
SCHS351A − JANUARY 2004 − REVISED JANUARY 2008
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage range, V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 6 V
CC
Input clamp current, I (V < 0 or V > V ) (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 mA
IK
I
I
CC
Output clamp current, I (V < 0 or V > V ) (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 mA
OK
O
O
CC
Continuous output current, I (V = 0 to V ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 mA
O
O
CC
Continuous current through V or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 mA
CC
Package thermal impedance, θ (see Note 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86°C/W
JA
Storage temperature range, T
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
stg
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
2. The package thermal impedance is calculated in accordance with JESD 51-7.
recommended operating conditions (see Note 3)
−40°C to
125°C
T
A
= 25°C
UNIT
MIN
4.5
2
MAX
MIN
4.5
2
MAX
V
V
V
V
V
Supply voltage
5.5
5.5
V
V
CC
IH
IL
I
High-level input voltage
Low-level input voltage
Input voltage
0.8
0.8
V
0
0
V
CC
V
CC
0
0
V
CC
V
Output voltage
V
CC
V
O
I
I
High-level output current
Low-level output current
Input transition rise or fall rate
−24
24
−24
24
mA
mA
ns/V
OH
OL
∆t/∆v
10
10
NOTE 3: All unused inputs of the device must be held at V
or GND to ensure proper device operation. Refer to the TI application report,
CC
Implications of Slow or Floating CMOS Inputs, literature number SCBA004.
2
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
CD74ACT32-Q1
QUADRUPLE 2-INPUT POSITIVE-OR GATE
SCHS351A − JANUARY 2004 − REVISED JANUARY 2008
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
−40°C to
125°C
T
A
= 25°C
PARAMETER
TEST CONDITIONS
V
CC
UNIT
MIN
4.4
MAX
MIN
MAX
I
I
I
I
I
I
= −50 µA
= −24 mA
= −50 mA
= 50 µA
4.5 V
4.5 V
5.5 V
4.5 V
4.5 V
5.5 V
5.5 V
5.5 V
4.4
3.7
OH
OH
OH
OL
OL
OL
3.94
V
OH
V = V or V
I IH
V
IL
†
3.85
0.1
0.1
0.5
1.65
1
= 24 mA
0.36
V
OL
V = V or V
V
I
IH
IL
†
= 50 mA
I
V = V or GND
0.1
4
µA
µA
I
I
CC
I
V = V or GND,
I
O
= 0
80
CC
I
CC
4.5 V to
5.5 V
‡
DI
V = V − 2.1 V
2.4
3
mA
I
CC
CC
C
10
10
pF
i
†
‡
Test one output at a time, not exceeding 1-second duration. Measurement is made by forcing indicated current and measuring voltage to minimize
power dissipation. Test verifies a minimum 75-Ω transmission-line drive capability at 125°C.
Additional quiescent supply current per input pin, TTL inputs high, 1 unit load
ACT INPUT LOAD TABLE
INPUT
UNIT LOAD
All
0.42
Unit load is ∆I
limit specified in
CC
electrical characteristics table
(e.g., 2.4 mA at 25°C).
switching characteristics over recommended operating free-air temperature range,
VCC = 5 V 0.5 V, CL = 50 pF (unless otherwise noted) (see Figure 1)
−40°C to
125°C
FROM
(INPUT)
TO
(OUTPUT)
PARAMETER
UNIT
MIN
3
MAX
t
t
12.1
12.1
PLH
A or B
Y
ns
3
PHL
operating characteristics, VCC = 5 V, TA = 25°C
PARAMETER
TYP
UNIT
C
Power dissipation capacitance
47
pF
pd
3
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
CD74ACT32-Q1
QUADRUPLE 2-INPUT POSITIVE-OR GATE
SCHS351A − JANUARY 2004 − REVISED JANUARY 2008
PARAMETER MEASUREMENT INFORMATION
2 × V
CC
TEST
S1
S1
t
t
/t
Open
R1 = 500 Ω
R2 = 500 Ω
Open
GND
PLH PHL
From Output
Under Test
t
/t
2 × V
PLZ PZL
CC
/t
GND
PHZ PZH
C = 50 pF
L
(see Note A)
t
w
3 V
0 V
1.5 V
1.5 V
Input
LOAD CIRCUIT
VOLTAGE WAVEFORMS
PULSE DURATION
3 V
Reference
Input
3 V
0 V
1.5 V
CLR
Input
1.5 V
0 V
t
t
h
su
t
rec
3 V
0 V
Data
Input
90%
t
90%
3 V
0 V
1.5 V
10%
1.5 V
10%
1.5 V
CLK
t
r
f
VOLTAGE WAVEFORMS
RECOVERY TIME
VOLTAGE WAVEFORMS
SETUP AND HOLD AND INPUT RISE AND FALL TIMES
3 V
0 V
3 V
Input
1.5 V
1.5 V
Output
Control
1.5 V
1.5 V
0 V
t
t
PHL
PLH
t
t
PLZ
PZL
V
OH
Output
Waveform 1
In-Phase
Output
90%
t
90%
≈V
CC
50%
10%
50% V
10%
CC
20% V
20% V
CC
V
OL
S1 at 2 × V
CC
CC
t
r
f
V
OL
(see Note B)
t
t
PLH
PHL
t
t
PHZ
PZH
V
V
OH
90%
90%
Output
Waveform 2
S1 at GND
Out-of-Phase
Output
50% V
10%
50%
10%
CC
V
OH
80% V
80% V
CC
CC
OL
t
t
r
f
≈0 V
(see Note B)
VOLTAGE WAVEFORMS
PROPAGATION DELAY AND OUTPUT TRANSITION TIMES
VOLTAGE WAVEFORMS
OUTPUT ENABLE AND DISABLE TIMES
NOTES: A. C includes probe and test-fixture capacitance.
L
B. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control.
Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control.
C. All input pulses are supplied by generators having the following characteristics: PRR ≤ 1 MHz, Z = 50 Ω, t = 3 ns, t = 3 ns.
O
r
f
Phase relationships between waveforms are arbitrary.
D. For clock inputs, f is measured with the input duty cycle at 50%.
max
E. The outputs are measured one at a time with one input transition per measurement.
F.
G.
H.
t
t
t
and t
and t
and t
are the same as t .
PLH
PZL
PLZ
PHL
PZH
PHZ
pd
are the same as t
.
en
are the same as t
.
dis
I. All parameters and waveforms are not applicable to all devices.
Figure 1. Load Circuit and Voltage Waveforms
4
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
PACKAGE OPTION ADDENDUM
www.ti.com
23-Aug-2012
PACKAGING INFORMATION
Status (1)
Eco Plan (2)
MSL Peak Temp (3)
Samples
Orderable Device
Package Type Package
Drawing
Pins
Package Qty
Lead/
Ball Finish
(Requires Login)
CD74ACT32QM96G4Q1
ACTIVE
SOIC
D
14
2500
Green (RoHS
& no Sb/Br)
CU NIPDAU Level-1-260C-UNLIM
CD74ACT32QM96Q1
CD74ACT32QPWRQ1
OBSOLETE
OBSOLETE
SOIC
D
14
14
TBD
TBD
Call TI
Call TI
Call TI
Call TI
TSSOP
PW
(1) The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2) Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability
information and additional product content details.
TBD: The Pb-Free/Green conversion plan has not been defined.
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that
lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.
Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between
the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above.
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight
in homogeneous material)
(3) MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature.
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information
provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and
continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals.
TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release.
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis.
OTHER QUALIFIED VERSIONS OF CD74ACT32-Q1 :
Catalog: CD74ACT32
•
Military: CD54ACT32
•
Addendum-Page 1
PACKAGE OPTION ADDENDUM
www.ti.com
23-Aug-2012
NOTE: Qualified Version Definitions:
Catalog - TI's standard catalog product
•
•
Military - QML certified for Military and Defense Applications
Addendum-Page 2
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other
changes to its semiconductor products and services per JESD46C and to discontinue any product or service per JESD48B. Buyers should
obtain the latest relevant information before placing orders and should verify that such information is current and complete. All
semiconductor products (also referred to herein as “components”) are sold subject to TI’s terms and conditions of sale supplied at the time
of order acknowledgment.
TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI’s terms
and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary
to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily
performed.
TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and
applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or
other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information
published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or
endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the
third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration
and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered
documentation. Information of third parties may be subject to additional restrictions.
Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service
voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice.
TI is not responsible or liable for any such statements.
Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements
concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support
that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which
anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause
harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use
of any TI components in safety-critical applications.
In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI’s goal is to
help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and
requirements. Nonetheless, such components are subject to these terms.
No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties
have executed a special agreement specifically governing such use.
Only those TI components which TI has specifically designated as military grade or “enhanced plastic” are designed and intended for use in
military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components
which have not been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and
regulatory requirements in connection with such use.
TI has specifically designated certain components which meet ISO/TS16949 requirements, mainly for automotive use. Components which
have not been so designated are neither designed nor intended for automotive use; and TI will not be responsible for any failure of such
components to meet such requirements.
Products
Audio
Applications
www.ti.com/audio
amplifier.ti.com
dataconverter.ti.com
www.dlp.com
Automotive and Transportation www.ti.com/automotive
Communications and Telecom www.ti.com/communications
Amplifiers
Data Converters
DLP® Products
DSP
Computers and Peripherals
Consumer Electronics
Energy and Lighting
Industrial
www.ti.com/computers
www.ti.com/consumer-apps
www.ti.com/energy
dsp.ti.com
Clocks and Timers
Interface
www.ti.com/clocks
interface.ti.com
logic.ti.com
www.ti.com/industrial
www.ti.com/medical
www.ti.com/security
Medical
Logic
Security
Power Mgmt
Microcontrollers
RFID
power.ti.com
Space, Avionics and Defense www.ti.com/space-avionics-defense
microcontroller.ti.com
www.ti-rfid.com
Video and Imaging
www.ti.com/video
OMAP Mobile Processors www.ti.com/omap
Wireless Connectivity www.ti.com/wirelessconnectivity
TI E2E Community
e2e.ti.com
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2012, Texas Instruments Incorporated
相关型号:
CD74ACT323MX
Parallel In Parallel Out, ACT Series, 8-Bit, Bidirectional, True Output, CMOS, PDSO20,
GE