LM140LQML
LM140LQML Series 3-Terminal Positive Regulators
Literature Number: SNVS381
March 2006
LM140LQML Series
3-Terminal Positive Regulators
General Description
tion. If internal power dissipation becomes too high for the
heat sinking provided, the thermal shut-down circuit takes
over, preventing the IC from overheating.
The LM140L series of three terminal positive regulators is
available with several fixed output voltages making them
useful in a wide range of applications. The LM140LA is an
improved version of the LM78LXX series with a tighter out-
put voltage tolerance (specified over the full military tem-
perature range), higher ripple rejection, better regulation and
lower quiescent current. The LM140LA regulators have 2%
VOUT specification, 0.04%/V line regulation, and 0.01%/mA
Features
n Line regulation of 0.04%/V
n Load regulation of 0.01%/mA
n Output voltage tolerances of 2% at Tj = 25˚C and 4%
over the temperature range
load regulation. When used as a zener diode/resistor com-
bination replacement, the LM140LA usually results in an
effective output impedance improvement of two orders of
magnitude, and lower quiescent current. These regulators
can provide local on card regulation, eliminating the distribu-
tion problems associated with single point regulation. The
voltages available allow the LM140LA to be used in logic
systems, instrumentation, Hi-Fi, and other solid state elec-
tronic equipment. Although designed primarily as fixed volt-
age regulators, these devices can be used with external
components to obtain adjustable voltages and currents.
n Output current of 100 mA
n Internal thermal overload protection
n Output transistor safe area protection
n Internal short circuit current limit
Output Voltage Options
Device ID
LM140LA-5.0
LM140LA-12
LM140LA-15
Output Voltage
5V
12V
15V
With adequate heat sinking the regulator can deliver 100 mA
output current. Current limiting is included to limit the peak
output current to a safe value. Safe area protection for the
output transistor is provided to limit internal power dissipa-
Ordering Information
NS Part Number
LM140LAH-5.0/883
LM140LAH-12/883
LM140LAH-15/883
JAN Part Number
NS Package Number
Package Description
3LD T0–39 Metal Can
3LD T0–39 Metal Can
3LD T0–39 Metal Can
H03A
H03A
H03A
Connection Diagrams
TO-39 Metal Can Package (H)
20155302
Bottom View
See NS Package Number H03A
© 2006 National Semiconductor Corporation
DS201553
www.national.com
Equivalent Circuit
20155301
www.national.com
2
Absolute Maximum Ratings (Note 1)
Input Voltage
35V
Internal Power Dissipation (Note 2)
Operating Temperature Range
Maximum Junction Temperature
Storage Temperature Range
Lead Temperature (Soldering, 10 sec.)
Thermal Resistance
Internally Limited
−55˚C ≤ TA ≤ +125˚C
+150˚C
−65˚C ≤ TA ≤ +150˚C
+300˚C
θJA
@
Still Air 0.5W
201˚C/W
79˚C/W
38˚C/W
TBD
@
500LF / Min Air Flow 0.5W
@
1.0W)
θJC
(
ESD Susceptibility (Note 3)
Quality Conformance Inspection
Mil-Std-883, Method 5005 - Group A
Subgroup
Description
Static tests at
Temp ˚C
25
1
2
Static tests at
125
-55
25
3
Static tests at
4
Dynamic tests at
Dynamic tests at
Dynamic tests at
Functional tests at
Functional tests at
Functional tests at
Switching tests at
Switching tests at
Switching tests at
Settling time at
Settling time at
Settling time at
5
125
-55
25
6
7
8A
8B
9
125
-55
25
10
11
12
13
14
125
-55
25
125
-55
3
www.national.com
LM140LA-5.0 Electrical Characteristics
DC Parameters
The following conditions apply, unless otherwise specified.
DC: VI = 10V, IL = 40mA
Sub-
groups
Symbol
IQ
Parameter
Quiescent Current
Conditions
Notes
Min Max
Unit
4.5
4.2
mA
mA
V
1
2
VO
Output Voltage
4.9
4.8
4.8
4.8
4.8
-20
-40
-30
-30
-0.1
-0.5
5.1
5.2
5.2
5.2
5.2
20
1
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1
VI = 20V, IL = 5mA
V
VI = 20V, IL = 100mA
VI = 7.2V, IL = 5mA
VI = 7.2V, IL = 100mA
5mA ≤ IL ≤ 40 mA
5mA ≤ IL ≤ 100mA
IL = 100mA, 7.5V ≤ VI ≤ 25V
7V ≤ VI ≤ 25V
V
V
V
RLoad
RLine
∆IQ
Load Regulation
mV
mV
mV
mV
mA
mA
40
1
Line Regulation
30
1
30
1
Quiescent Current Change
5mA ≤ IL ≤ 40mA
0.1
0.5
1, 2, 3
1
7.5V ≤ VI ≤ 35V
AC Parameters
Sub-
groups
4
Symbol
RR
Parameter
Ripple Rejection
Conditions
Notes
Min Max
Unit
ƒ = 120Hz, eI = 1VRMS
55
dB
LM140LA-12 Electrical Characteristics
DC Parameters
The following conditions apply, unless otherwise specified.
DC: VI = 19V, IL = 40mA
Sub-
groups
Symbol
IQ
Parameter
Quiescent Current
Conditions
Notes
Min Max
Unit
4.5
4.2
mA
mA
V
1
2
VO
Output Voltage
11.75 12.25
11.5 12.5
11.5 12.5
11.5 12.5
11.5 12.5
1
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1
VI = 27V, IL = 5mA
V
VI = 27V, IL = 100mA
VI = 14.5V, IL = 5mA
VI = 14.5V, IL = 100mA
5mA ≤ IL ≤ 40mA
V
V
V
RLoad
RLine
∆IQ
Load Regulation
-40
-80
-65
-65
-0.1
-0.5
40
80
mV
mV
mV
mV
mA
mA
5mA ≤ IL ≤ 100mA
IL = 100mA, 14.5V ≤ VI ≤ 30V
14.2V ≤ VI ≤ 30V
1
Line Regulation
65
1
65
1
Quiescent Current Change
5mA ≤ IL ≤ 40mA
0.1
0.5
1, 2, 3
1
14.3V ≤ VI ≤ 35V
AC Parameters
Sub-
groups
4
Symbol
Parameter
Ripple Rejection
Conditions
Notes
Min Max
Unit
RR
ƒ = 120Hz, eI = 1VRMS
47
dB
www.national.com
4
LM140LA-15 Electrical Characteristics
DC Parameters
The following conditions apply, unless otherwise specified.
DC: VI = 23V, IL = 40mA
Sub-
groups
Symbol
IQ
Parameter
Quiescent Current
Conditions
Notes
Min Max
Unit
4.5
4.2
mA
mA
V
1
2
VO
Output Voltage
14.7 15.3
14.4 15.6
14.4 15.6
14.4 15.6
14.4 15.6
1
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1
VI = 30V, IL = 5mA
V
VI = 30V, IL = 100mA
VI = 17.6V, IL = 5mA
VI = 17.6V, IL = 100mA
5mA ≤ IL ≤ 40mA
V
V
V
RLoad
RLine
∆IQ
Load Regulation
-50
50
mV
mV
mV
mV
mA
mA
5mA ≤ IL ≤ 100mA
IL = 100mA, 17.3V ≤ VI ≤ 30V
17.3V ≤ VI ≤ 30V
-100 100
1
Line Regulation
-70
-70
70
70
1
1
Quiescent Current Change
5mA ≤ IL ≤ 40mA
-0.1
-0.5
0.1
0.5
1, 2, 3
1
17.5V ≤ VI ≤ 35V
AC Parameters
Sub-
groups
4
Symbol
RR
Parameter
Ripple Rejectionƒ
Conditions
Notes
Min Max
Unit
f = 120Hz, eI = 1VRMS
47
dB
Note 1: Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for which the device is
functional, but do not guarantee specific performance limits. For guaranteed specifications and test conditions, see the Electrical Characteristics. The guaranteed
specifications apply only for the test conditions listed. Some performance characteristics may degrade when the device is not operated under the listed test
conditions.
Note 2: The maximum power dissipation must be derated at elevated temperatures and is dictated by T
(maximum junction temperature), θ (package junction
JA
Jmax
to ambient thermal resistance), and T (ambient temperature). The maximum allowable power dissipation at any temperature is P
= (T
- T )/θ or the
A
Dmax
Jmax A JA
number given in the Absolute Maximum Ratings, whichever is lower.
Note 3: Human body model, 100pF discharged through 1.5KΩ
Note 4: It is recommended that a minimum load capacitor of 0.01 µF be used to limit the high frequency noise bandwidth.
5
www.national.com
Typical Performance Characteristics
Maximum Average Power
Dissipation
Maximum Average
Power Dissipation
20155307
20155308
20155311
20155313
Peak Output Current
Dropout Voltage
20155310
Output Impedance
Ripple Rejection
20155312
www.national.com
6
Typical Performance Characteristics (Continued)
Quiescent Current
Quiescent Current
20155315
20155314
Typical Applications (Note 4)
Fixed Output Regulator
20155305
*Required if the regulator is located far from the power supply filter.
**See note 3 in the electrical characteristics table.
Adjustable Output Regulator
20155306
V
OUT
= 5V + (5V/R1 + I ) R2
O
5V/R1 = 3 I load regulation (L,) [(R1 + R2)/R1] (L, of LM140LA-5.0)
O
7
www.national.com
Revision History
Released
Revision
Section
Originator
Changes
03/10/06
A
New release to corporate format
L. Lytle
3 MDS data sheets converted into one Corp.
data sheet format. Drift tables were removed
from electrical characteristics since not
performed on 883 product. MDS data sheets
MNLM140LA-05-H Rev. 0B0,
MNLM140LA-12-H Rev. 0B0 and
MNLM140LA-15-H Rev. 0B0. will be
archived.
www.national.com
8
Physical Dimensions inches (millimeters) unless otherwise noted
TO-39 Metal Can Package (H)
NS Package Number H03A
National does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and National reserves
the right at any time without notice to change said circuitry and specifications.
For the most current product information visit us at www.national.com.
LIFE SUPPORT POLICY
NATIONAL’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS
WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT AND GENERAL COUNSEL OF NATIONAL SEMICONDUCTOR
CORPORATION. As used herein:
1. Life support devices or systems are devices or systems
which, (a) are intended for surgical implant into the body, or
(b) support or sustain life, and whose failure to perform when
properly used in accordance with instructions for use
provided in the labeling, can be reasonably expected to result
in a significant injury to the user.
2. A critical component is any component of a life support
device or system whose failure to perform can be reasonably
expected to cause the failure of the life support device or
system, or to affect its safety or effectiveness.
BANNED SUBSTANCE COMPLIANCE
National Semiconductor manufactures products and uses packing materials that meet the provisions of the Customer Products
Stewardship Specification (CSP-9-111C2) and the Banned Substances and Materials of Interest Specification (CSP-9-111S2) and contain
no ‘‘Banned Substances’’ as defined in CSP-9-111S2.
Leadfree products are RoHS compliant.
National Semiconductor
Americas Customer
Support Center
National Semiconductor
Europe Customer Support Center
Fax: +49 (0) 180-530 85 86
National Semiconductor
Asia Pacific Customer
Support Center
National Semiconductor
Japan Customer Support Center
Fax: 81-3-5639-7507
Email: new.feedback@nsc.com
Tel: 1-800-272-9959
Email: europe.support@nsc.com
Deutsch Tel: +49 (0) 69 9508 6208
English Tel: +44 (0) 870 24 0 2171
Français Tel: +33 (0) 1 41 91 8790
Email: ap.support@nsc.com
Email: jpn.feedback@nsc.com
Tel: 81-3-5639-7560
www.national.com
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements,
and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should
obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are
sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment.
TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard
warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where
mandated by government requirements, testing of all parameters of each product is not necessarily performed.
TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and
applications using TI components. To minimize the risks associated with customer products and applications, customers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right,
or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information
published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a
warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual
property of the third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied
by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive
business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional
restrictions.
Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all
express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not
responsible or liable for any such statements.
TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably
be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing
such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and
acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products
and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be
provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in
such safety-critical applications.
TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are
specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military
specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at
the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use.
TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are
designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated
products in automotive applications, TI will not be responsible for any failure to meet such requirements.
Following are URLs where you can obtain information on other Texas Instruments products and application solutions:
Products
Audio
Applications
www.ti.com/audio
amplifier.ti.com
dataconverter.ti.com
www.dlp.com
Communications and Telecom www.ti.com/communications
Amplifiers
Data Converters
DLP® Products
DSP
Computers and Peripherals
Consumer Electronics
Energy and Lighting
Industrial
www.ti.com/computers
www.ti.com/consumer-apps
www.ti.com/energy
dsp.ti.com
www.ti.com/industrial
www.ti.com/medical
www.ti.com/security
Clocks and Timers
Interface
www.ti.com/clocks
interface.ti.com
logic.ti.com
Medical
Security
Logic
Space, Avionics and Defense www.ti.com/space-avionics-defense
Transportation and Automotive www.ti.com/automotive
Power Mgmt
Microcontrollers
RFID
power.ti.com
microcontroller.ti.com
www.ti-rfid.com
Video and Imaging
www.ti.com/video
OMAP Mobile Processors www.ti.com/omap
Wireless Connectivity www.ti.com/wirelessconnectivity
TI E2E Community Home Page
e2e.ti.com
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2011, Texas Instruments Incorporated
相关型号:
©2020 ICPDF网 联系我们和版权申明