LM741 MD8 [TI]
Military-grade, single, 44-V, 1-MHz operational amplifier | Y | 0 | -55 to 125;型号: | LM741 MD8 |
厂家: | TEXAS INSTRUMENTS |
描述: | Military-grade, single, 44-V, 1-MHz operational amplifier | Y | 0 | -55 to 125 放大器 运算放大器 放大器电路 |
文件: | 总11页 (文件大小:651K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
LM741QML
LM741QML Operational Amplifier
Literature Number: SNOSAN4
August 2005
LM741QML
Operational Amplifier
General Description
The LM741 is a general purpose operational amplifier which
features improved performance over industry standards
such as the LM709. They are direct, plug-in replacements for
the 709C, LM201, MC1439 and 748 in most applications.
Features
The amplifier offers many features which make their appli-
cation nearly foolproof: overload protection on the input and
output, no latch-up when the common mode range is ex-
ceeded, as well as freedom from oscillations.
Ordering Information
NS Part Number
JAN Part Number
NS Package Number
Package Description
8 LD Metal Can
LM741H/883
H08C
J08A
LM741J/883
8LD CERDIP
LM741W/883
LM741WG/883
W10A
WG10A
10LD CERPACK
10LD Ceramic SOIC
Connection Diagrams
Metal Can Package
Dual-In-LinePackage
20143903
20143902
See NS Package Number J08A
See NS Package Number H08C
Ceramic Flatpak and SOIC Package
20143906
See NS Package Number W10A & WG10A
© 2005 National Semiconductor Corporation
DS201439
www.national.com
Schematic Diagram
20143901
www.national.com
2
Absolute Maximum Ratings (Note 1)
Supply Voltage
22V
500 mW
Power Dissipation (Note 2)
Differential Input Voltage
Input Voltage (Note 3)
Output Short Circuit Duration
Operating Temperature Range
Storage Temperature Range
Junction Temperature (TJ)
Lead Temperature (Soldering, 10 Seconds)
Thermal Resistance
θJA
30V
15V
Continuous
−55˚C ≤ TA ≤ +125˚C
−65˚C ≤ TA ≤ +150˚C
150˚C
300˚C
Metal Can (Still Air)
Metal Can (500LF / Min Air Flow)
CERDIP (Still Air)
167˚C/W
100˚C/W
TBD
CERDIP (500LF / Min Air Flow)
CERPACK (Still Air)
CERPACK (500LF / Min Air Flow)
Ceramic SOIC (Still Air)
Ceramic SOIC (500LF / Min Air Flow)
θJC
TBD
228˚C/W
154˚C/W
228˚C/W
154˚C/W
Metal Can
44˚C/W
TBD
CERDIP
CERPACK
27˚C/W
27˚C/W
Ceramic SOIC
Package Weight (typical)
Metal Can
1000mg
1100mg
260mg
225mg
400V
CERDIP
CERPACK
Ceramic SOIC
ESD Tolerance (Note 4)
Quality Conformance Inspection
Mil-Std-883, Method 5005 - Group A
Subgroup
Description
Static tests at
Temp ˚C
25
1
2
3
4
5
6
Static tests at
125
-55
25
Static tests at
Dynamic tests at
Dynamic tests at
Dynamic tests at
125
-55
25
7
Functional tests at
Functional tests at
Functional tests at
Switching tests at
Switching tests at
Switching tests at
Settling time at
8A
8B
9
125
-55
25
10
11
12
13
14
125
-55
25
Settling time at
125
-55
Settling time at
3
www.national.com
Electrical Characteristics
DC Parameters
The following conditions apply to all the following parameters, unless otherwise specified.
DC: VCC
=
15V, VCM = 0V
Sub-
group
1
Symbol
Parameter
Conditions
VCM = -12V
Notes
Min Max
Unit
VIO
Input Offset Voltage
-5.0
-6.0
-5.0
-6.0
-5.0
-6.0
-5.0
-6.0
5.0
6.0
5.0
6.0
5.0
6.0
5.0
6.0
-6.0
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
nA
2, 3
1
VCM = 12V
2, 3
1
2, 3
1
+VCC
=
5V
2, 3
1, 2, 3
1, 2, 3
1
-VIO Adj
+VIO Adj
IIO
Offset Null
Offset Null
6.0
Input Offset Current
VCM = -12V
VCM = 12V
-200 200
-500 500
-200 200
-500 500
-200 200
-500 500
-200 200
-500 500
nA
2, 3
1
nA
nA
2, 3
1
nA
nA
2, 3
1
VCC
=
5V
nA
nA
2, 3
1
IIB
Input Bias Current
VCM = -12V
VCM = 12V
0.0
0.0 1500
0.0 500
0.0 1500
0.0 500
0.0 1500
0.0 500
500
nA
nA
2, 3
1
nA
nA
2, 3
1
nA
nA
2, 3
1
VCC
=
5V
mA
nA
0.0 1500
2, 3
1
ICC
Power Supply Current
2.8
mA
mA
mA
V/mV
V/mV
V/mV
V/mV
dB
2.5
2
3.5
3
+AVS
−AVS
Open Loop Voltage Gain
Open Loop Voltage Gain
RL = 2KΩ, VO = 0 to 10V
RL = 2KΩ, VO = 0 to −10V
(Note 7)
(Note 7)
(Note 7)
(Note 7)
50
25
50
25
77
77
1
2, 3
1
2, 3
1, 2, 3
1, 2, 3
+PSRR
-PSRR
Power Supply Rejection Ratio
Power Supply Rejection Ratio
+VCC = 15V to 5V, -VCC = -15V
-VCC = -15V to -5V,
+VCC = +15V
dB
CMRR
+IOS
Common Mode Rejection Ratio -12V ≤ VCM ≤ 12V
70
dB
mA
mA
mA
mA
V
1, 2, 3
1,2
Output Short Circuit Current
-45
-50
5.0
5.0
12
-5.0
-5.0
45
3
-IOS
Output Short Circuit Current
1,2
50
3
+VOpp
Output Voltage Swing
RL = 10KΩ
RL = 2KΩ
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
10
V
VCC
VCC
=
=
20V, RL = 10KΩ
20V, RL = 2KΩ
16
V
15
V
www.national.com
4
Electrical Characteristics (Continued)
DC Parameters (Continued)
The following conditions apply to all the following parameters, unless otherwise specified.
DC: VCC
=
15V, VCM = 0V
Sub-
group
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1
Symbol
Parameter
Conditions
Notes
Min Max
Unit
-VOpp
Output Voltage Swing
RL = 10KΩ
RL = 2KΩ
-12
-10
V
V
VCC
VCC
=
=
20V, RL = 10KΩ
20V, RL = 2KΩ
-16
V
-15
V
RI
Input Resistance
(Note 6)
(Note 5)
(Note 6)
0.3
MΩ
V
VI
Input Voltage Range
Output Voltage Swing
VCC
VCC
=
=
15V
5V
12
1, 2, 3
1, 2, 3
VO
2.0
V
AC Parameters
The following conditions apply to all the following parameters, unless otherwise specified.
AC: VCC
=
15V, VCM = 0V
Parameter
Sub-
group
7
Symbol
Conditions
Notes
Min Max
Unit
+SR
Slew Rate
Slew Rate
VI = -5V to 5V, AV = 1, RL
=
0.2
V/µS
2KΩ
-SR
VI = 5V to -5V, AV =1, RL
=
0.2
V/µS
7
2KΩ
tR
Rise Time
Overshoot
RL = 2KΩ, AV = 1, CL = 100pF
RL = 2KΩ, AV = 1, CL = 100pF
VI = 50mVRMS, ƒ = 20KHz, RL
= 2KΩ
1.0
30
µS
%
7
7
-
OS
GBW
Gain Bandwidth
250
KHz
Note 1: Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for which the device is
functional, but do not guarantee specific performance limits. For guaranteed specifications and test conditions, see the Electrical Characteristics. The guaranteed
specifications apply only for the test conditions listed. Some performance characteristics may degrade when the device is not operated under the listed test
conditions.
Note 2: The maximum power dissipation must be derated at elevated temperatures and is dictated by T
(maximum junction temperature), θ (package junction
JA
Jmax
to ambient thermal resistance), and T (ambient temperature). The maximum allowable power dissipation at any temperature is P
= (T
- T )/θ or the
A
Dmax
Jmax A JA
number given in the Absolute Maximum Ratings, whichever is lower.
Note 3: For supply voltages less than 15V, the absolute maximum input voltage is equal to the supply voltage.
Note 4: Human body model, 1.5 kΩ in series with 100 pF.
Note 5: Guaranteed by CMRR, I , I , V
IB IO
IO
Note 6: Guaranteed parameter, not tested.
Note 7: Datalog reading in K = V/mV
Typical Application
Offset Nulling Circuit
20143907
5
www.national.com
Revision History
Date
Revision
Section
Originator
Changes
Released
08/22/05
A
New Release to the corporate format L. Lytle
1 MDS datasheet converted into one
corporate datasheet format. Since drift is not
performed on 883 product, the table was
removed. MNLM741-X Rev 1A0 will be
archived.
www.national.com
6
Physical Dimensions inches (millimeters) unless otherwise noted
Metal Can Package (H)
NS Package Number H08C
Ceramic Dual-In-Line Package (J)
NS Package Number J08A
7
www.national.com
Physical Dimensions inches (millimeters) unless otherwise noted (Continued)
10–Lead Ceramic SOIC (WG)
NS Package Number WG10A
10-Lead Ceramic Flatpak (W)
NS Package Number W10A
www.national.com
8
Notes
National does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and National reserves
the right at any time without notice to change said circuitry and specifications.
For the most current product information visit us at www.national.com.
LIFE SUPPORT POLICY
NATIONAL’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS
WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT AND GENERAL COUNSEL OF NATIONAL SEMICONDUCTOR
CORPORATION. As used herein:
1. Life support devices or systems are devices or systems
which, (a) are intended for surgical implant into the body, or
(b) support or sustain life, and whose failure to perform when
properly used in accordance with instructions for use
provided in the labeling, can be reasonably expected to result
in a significant injury to the user.
2. A critical component is any component of a life support
device or system whose failure to perform can be reasonably
expected to cause the failure of the life support device or
system, or to affect its safety or effectiveness.
BANNED SUBSTANCE COMPLIANCE
National Semiconductor manufactures products and uses packing materials that meet the provisions of the Customer Products
Stewardship Specification (CSP-9-111C2) and the Banned Substances and Materials of Interest Specification (CSP-9-111S2) and contain
no ‘‘Banned Substances’’ as defined in CSP-9-111S2.
Leadfree products are RoHS compliant.
National Semiconductor
Americas Customer
Support Center
National Semiconductor
Europe Customer Support Center
Fax: +49 (0) 180-530 85 86
National Semiconductor
Asia Pacific Customer
Support Center
National Semiconductor
Japan Customer Support Center
Fax: 81-3-5639-7507
Email: new.feedback@nsc.com
Tel: 1-800-272-9959
Email: europe.support@nsc.com
Deutsch Tel: +49 (0) 69 9508 6208
English Tel: +44 (0) 870 24 0 2171
Français Tel: +33 (0) 1 41 91 8790
Email: ap.support@nsc.com
Email: jpn.feedback@nsc.com
Tel: 81-3-5639-7560
www.national.com
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements,
and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should
obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are
sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment.
TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard
warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where
mandated by government requirements, testing of all parameters of each product is not necessarily performed.
TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and
applications using TI components. To minimize the risks associated with customer products and applications, customers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right,
or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information
published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a
warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual
property of the third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied
by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive
business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional
restrictions.
Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all
express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not
responsible or liable for any such statements.
TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably
be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing
such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and
acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products
and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be
provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in
such safety-critical applications.
TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are
specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military
specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at
the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use.
TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are
designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated
products in automotive applications, TI will not be responsible for any failure to meet such requirements.
Following are URLs where you can obtain information on other Texas Instruments products and application solutions:
Products
Audio
Applications
www.ti.com/audio
amplifier.ti.com
dataconverter.ti.com
www.dlp.com
Communications and Telecom www.ti.com/communications
Amplifiers
Data Converters
DLP® Products
DSP
Computers and Peripherals
Consumer Electronics
Energy and Lighting
Industrial
www.ti.com/computers
www.ti.com/consumer-apps
www.ti.com/energy
dsp.ti.com
www.ti.com/industrial
www.ti.com/medical
www.ti.com/security
Clocks and Timers
Interface
www.ti.com/clocks
interface.ti.com
logic.ti.com
Medical
Security
Logic
Space, Avionics and Defense www.ti.com/space-avionics-defense
Transportation and Automotive www.ti.com/automotive
Power Mgmt
Microcontrollers
RFID
power.ti.com
microcontroller.ti.com
www.ti-rfid.com
Video and Imaging
www.ti.com/video
OMAP Mobile Processors www.ti.com/omap
Wireless Connectivity www.ti.com/wirelessconnectivity
TI E2E Community Home Page
e2e.ti.com
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2011, Texas Instruments Incorporated
相关型号:
LM741AJ/883
Operational Amplifier, 1 Func, 3000uV Offset-Max, BIPolar, CDIP14, CERAMIC, DIP-14
ROCHESTER
©2020 ICPDF网 联系我们和版权申明