LM92CIM/NOPB [TI]

具有警报功能和 I2C/SMBus 接口的 ±0.5°C 温度传感器 | D | 8 | -55 to 150;
LM92CIM/NOPB
型号: LM92CIM/NOPB
厂家: TEXAS INSTRUMENTS    TEXAS INSTRUMENTS
描述:

具有警报功能和 I2C/SMBus 接口的 ±0.5°C 温度传感器 | D | 8 | -55 to 150

温度传感 输出元件 传感器 换能器 温度传感器
文件: 总25页 (文件大小:1450K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
LM92  
www.ti.com  
SNIS110D MARCH 2000REVISED MARCH 2013  
±0.33°C Accurate, 12-Bit + Sign Temperature Sensor and Thermal Window Comparator  
With Two-Wire Interface  
Check for Samples: LM92  
1
FEATURES  
DESCRIPTION  
The LM92 is a digital temperature sensor and thermal  
window comparator with an I2C™ Serial Bus interface  
and an accuracy of ±0.33°C. The window-comparator  
architecture of the LM92 eases the design of  
temperature control systems. The open-drain  
Interrupt (INT) output becomes active whenever  
temperature goes outside a programmable window,  
23  
Window Comparison Simplifies Design of  
ACPI-Compatible Temperature Monitoring and  
Control  
Serial Bus Interface  
Separate Open-Drain Outputs for Interrupt and  
Critical Temperature Shutdown  
while  
a
separate Critical Temperature Alarm  
Shutdown Mode to Minimize Power  
Consumption  
(T_CRIT_A) output becomes active when the  
temperature exceeds a programmable critical limit.  
The INT output can operate in either a comparator or  
event mode, while the T_CRIT_A output operates in  
comparator mode only.  
Up to Four LM92s can be Connected to a  
Single Bus  
12-Bit + Sign Output  
Operation up to 150°C  
The host can program both the upper and lower limits  
of the window as well as the critical temperature limit.  
Programmable Hysteresis as well as a fault queue  
are available to minimize false tripping. Two pins (A0,  
A1) are available for address selection. The sensor  
powers up with default thresholds of 2°C THYST, 10°C  
TLOW, 64°C THIGH, and 80°C T_CRIT.  
APPLICATIONS  
HVAC  
Medical Electronics  
Electronic Test Equipment  
System Thermal Management  
Personal Computers  
Office Electronics  
Automotive  
The LM92's 2.7V to 5.5V supply voltage range, Serial  
Bus interface, 12-bit + sign output, and full-scale  
range of over 128°C make it ideal for a wide range of  
applications. These include thermal management and  
protection applications in personal computers,  
electronic test equipment, office electronics,  
automotive, medical and HVAC applications.  
KEY SPECIFICATIONS  
Supply Voltage 2.7V to 5.5V  
Supply Current operating 350 μA (typ) 625 μA  
(max) shutdown 5 μA (typ)  
Temperature Accuracy  
30°C, ±0.33°C (max)  
10°C to 50°C, ±0.50°C (max)  
10°C to 85°C, ±1.0°C (max)  
125°C, ±1.25°C (max)  
25°C to 150°C, ±1.5°C (max)  
Linearity ±0.5°C (max)  
Resolution 0.0625°C  
1
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of  
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.  
2
3
I2C is a trademark of dcl_owner.  
All other trademarks are the property of their respective owners.  
PRODUCTION DATA information is current as of publication date.  
Products conform to specifications per the terms of the Texas  
Instruments standard warranty. Production processing does not  
necessarily include testing of all parameters.  
Copyright © 2000–2013, Texas Instruments Incorporated  
LM92  
SNIS110D MARCH 2000REVISED MARCH 2013  
www.ti.com  
Simplified Block Diagram  
Connection Diagram  
SOIC  
See Package Number D (R-PDSO-G8)  
Pin Description  
Label  
SDA  
Pin No.  
Function  
Typical Connection  
1
2
3
Serial Bi-Directional Data Line. Open Drain Output  
From Controller  
From Controller  
SCL  
Serial Bus Clock Input  
T_CRIT_A  
Critical Temperature Alarm Open Drain Output  
Pull Up Resistor, Controller Interrupt Line or System  
Hardware Shutdown  
GND  
INT  
4
5
Power Supply Ground  
Ground  
Interrupt Open Drain Output  
Positive Supply Voltage Input  
User-Set Address Inputs  
Pull Up Resistor, Controller Interrupt Line  
DC Voltage from 2.7V to 5.5V  
Ground (Low, “0”) or +VS (High, “1”)  
+V S  
A0–A1  
8
7,6  
2
Submit Documentation Feedback  
Copyright © 2000–2013, Texas Instruments Incorporated  
Product Folder Links: LM92  
LM92  
www.ti.com  
SNIS110D MARCH 2000REVISED MARCH 2013  
Typical Application  
Figure 1.  
These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam  
during storage or handling to prevent electrostatic damage to the MOS gates.  
(1)  
Absolute Maximum Ratings  
Supply Voltage  
0.3 V to 6.5V  
Voltage at any Pin  
Input Current at any Pin  
0.3 V to (+VS + 0.3V)  
5 mA  
20 mA  
(2)  
Package Input Current  
T_CRIT_A and INT Output Sink Current  
T_CRIT_A and INT Output Voltage  
Storage Temperature  
10 mA  
6.5V  
65°C to +125°C  
2500V  
(3)  
ESD Susceptibility  
Human Body Model  
Machine Model  
250V  
Soldering process must comply with Reflow Temperature Profile specifications. Refer to http://www.ti.com/lit/SNOA549.(4)  
(1) Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. DC and AC electrical specifications do not  
apply when operating the device beyond its rated operating conditions.  
(2) When the input voltage (VI) at any pin exceeds the power supplies (VI < GND or VI > +VS) the current at that pin should be limited to 5  
mA. The 20 mA maximum package input current rating limits the number of pins that can safely exceed the power supplies with an input  
current of 5 mA to four.  
(3) Human body model, 100 pF discharged through a 1.5 kΩ resistor. Machine model, 200 pF discharged directly into each pin.  
(4) Reflow temperature profiles are different for lead-free and non-lead-free packages.  
(1) (2)  
Operating Ratings  
Specified Temperature Range(3), TMIN to TMAX  
55°C to +150°C  
Supply Voltage Range (+VS)  
+2.7V to +5.5V  
(1) Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. DC and AC electrical specifications do not  
apply when operating the device beyond its rated operating conditions.  
(2) LM92 θJA (thermal resistance, junction-to-ambient) when attached to a printed circuit board with 2 oz. foil is 200 °C/W.  
(3) While the LM92 has a full-scale-range in excess of 128°C, prolonged operation at temperatures above 125 °C is not recommended.  
Copyright © 2000–2013, Texas Instruments Incorporated  
Submit Documentation Feedback  
3
Product Folder Links: LM92  
LM92  
SNIS110D MARCH 2000REVISED MARCH 2013  
www.ti.com  
Electrical Characteristics Temperature-to-Digital Converter Characteristics  
Unless otherwise noted, these specifications apply for +VS= +2.7V to +5.5V for LM92CIM . Boldface limits apply for TA = TJ  
= TMIN to TMAX; all other limits TA= TJ= +25°C, unless otherwise noted.  
Typical(1)  
Limits(2)  
Unit  
(Limit)  
Parameter  
Conditions  
Accuracy (This is a summary. For more  
T A = +30°C, +VS = 3.3V to 4.0V  
±0.33  
±0.50  
(3)  
detailed information please see  
)
T A = 10°C or +50°C, +VS = 3.3V to  
4.0V  
T A = 10 °C or +85°C, +VS = 3.3V  
±1.00  
°C (max)  
to 4.0V  
T A = +125°C, +VS = 4.0V  
±1.25  
±1.50  
T A = 25°C to 150°C, +VS = 4.0V  
(4)  
Resolution  
13  
0.0625  
Bits  
°C  
(5)  
Linearity  
±0.5  
°C (max)  
°C (max)  
°C/V (max)  
°C/V (max)  
ms  
(6)  
Offset Error of Transfer Function  
+VS = 4.0V  
Offset Error of Transfer Function Supply 2.7V +VS< 3.6V  
Sensitivity  
3.6V +VS5.5V  
(7)  
Temperature Conversion Time  
500  
0.35  
0.35  
5
1000  
Quiescent Current  
I2C Inactive  
I2C Active  
mA  
0.625  
mA (max)  
µA  
Shutdown Mode  
T HYST Default Temperature  
T LOW Default Temperature  
T HIGH Default Temperature  
T C Default Temperature  
(8)(9)2  
°C  
(9)  
(9)  
(9)  
10  
°C  
64  
°C  
80  
°C  
(1) Typical values are at TA = 25 °C and represent most likely parametric norm.  
(2) Limits are guaranteed to TI's AOQL (Average Outgoing Quality Level).  
(3) The limits found in Table 1 supersede the limits shown in the Electrical Characteristics Table. The Accuracy specification includes errors  
due to linearity, offset and gain. The accuracy specification includes effects of self heating with negligible digital output loading. Pull-up  
resistors should be maximized (10k typical recommended), so that self heating due to digital output loading is negligible.  
(4) Limits at intermediate temperatures can be calculated using a straight line interpolation as shown in Figure 2 and Figure 3.  
(5) Linearity Error is defined as the worse case difference of an actual reading to that of a calculated reading derived from the straight line  
whose endpoints are measured at 30°C and 125°C for the range of 30°C to 125°C or whose endpoints are measured at 30°C and  
25°C for the range of 30°C to 25°.  
(6) Offset Error calibration should be done at 30°C. The residual error of the transfer function is then equivalent to the Accuracy Limit minus  
the Offset Limit. This does not take into account the power supply sensitivity of the offset error. Nor, does it take into account the error  
introduced by the calibration system used.  
(7) This specification is provided only to indicate how often temperature data is updated. The LM92 can be read at any time without regard  
to conversion state (and will yield last conversion result). If a conversion is in process it will be interrupted and restarted after the end of  
the read.  
(8) 12 bits + sign, two's complement  
(9) Default values set at power up.  
Figure 2. Accuracy vs Temperature with +Vs = 5V  
4
Submit Documentation Feedback  
Copyright © 2000–2013, Texas Instruments Incorporated  
Product Folder Links: LM92  
 
LM92  
www.ti.com  
SNIS110D MARCH 2000REVISED MARCH 2013  
Figure 3. Accuracy vs Temperature with +Vs = 3.3V  
Table 1. Temperature Accuracy Parameter Limits  
Conditions  
T A = 25°C  
T A = 10°C  
T A = 0°C  
+VS=2.7V  
1.35/+1.50  
±1.00  
+VS=3.3V  
1.25/+1.50  
0.90/+1.00  
0.70/+0.75  
±0.50  
+VS=4V  
1.25/+1.50  
0.90/+1.00  
0.70/+0.75  
±0.50  
+VS=5V  
+VS=5.5V  
Unit  
1.05/+1.70  
0.70/+1.20  
0.50/+0.95  
0.30/+0.70  
0.13/+0.53  
0.30/+0.70  
0.80/+1.05  
1.05/+1.45  
1.30/+1.70  
1.05/+1.80  
0.70/+1.30  
0.50/+1.05  
0.30/+0.80  
0.13/+0.63  
0.30/+0.80  
0.80/+1.15  
1.05/+1.55  
1.30/+1.80  
°C (max)  
°C (max)  
°C (max)  
°C (max)  
°C (max)  
°C (max)  
°C (max)  
°C (max)  
°C (max)  
0.80/+0.75  
0.60/+0.50  
0.43/+0.33  
0.60/+0.50  
1.10/+0.85  
1.60/+1.25  
±1.90  
T A = 10°C  
T A = 30°C  
T A = 50°C  
T A = 85°C  
T A = 125°C  
T A = 150°C  
±0.33  
±0.33  
±0.50  
±0.50  
1.00/+0.85  
1.50/+1.25  
1.75/+1.50  
1.00/+0.85  
±1.25  
±1.50  
Digital DC Characteristics  
Unless otherwise noted, these specifications apply for +VS= +2.7V to +5.5V for LM92CIM . Boldface limits apply for TA = TJ  
= TMIN to TMAX; all other limits TA= TJ= +25 °C, unless otherwise noted.  
Typical(1)  
Limits(2)  
Unit  
(Limit)  
Symbol  
V IN(1)  
Parameter  
Conditions  
SDA and SCL Logical “1” Input  
Voltage  
+VS × 0.7  
V (min)  
+VS+0.3  
V (max)  
V (min)  
V IN(0)  
SDA and SCL Logical “0” Input  
Voltage  
0.3  
+VS × 0.3  
250  
V (max)  
mV (min)  
V (min)  
V (max)  
V (min)  
V (max)  
µA (max)  
µA (max)  
pF  
VIN(HYST)  
V IN(1)  
SDA and SCL Digital Input Hysteresis  
A0 and A1 Logical “1” Input Voltage  
500  
2.0  
+VS+0.3  
0.3  
V IN(0)  
A0 and A1 Logical “0” Input Voltage  
0.7  
I IN(1)  
I IN(0)  
C IN  
Logical “1” Input Current  
Logical “0” Input Current  
Capacitance of All Digital Inputs  
High Level Output Current  
Low Level Output Voltage  
V IN = + VS  
0.005  
0.005  
20  
1.0  
V IN = 0 V  
1.0  
I OH  
V OH = + VS  
I OL = 3 mA  
10  
µA (max)  
V (max)  
V OL  
0.4  
(1) Typical values are at TA = 25 °C and represent most likely parametric norm.  
(2) Limits are guaranteed to TI's AOQL (Average Outgoing Quality Level).  
Copyright © 2000–2013, Texas Instruments Incorporated  
Submit Documentation Feedback  
5
Product Folder Links: LM92  
LM92  
SNIS110D MARCH 2000REVISED MARCH 2013  
www.ti.com  
Digital DC Characteristics (continued)  
Unless otherwise noted, these specifications apply for +VS= +2.7V to +5.5V for LM92CIM . Boldface limits apply for TA = TJ  
= TMIN to TMAX; all other limits TA= TJ= +25 °C, unless otherwise noted.  
Typical(1)  
Limits(2)  
Unit  
(Limit)  
Symbol  
Parameter  
Conditions  
T_CRIT_A Output Saturation Voltage  
I OUT = 4.0 mA  
0.8  
1
V (max)  
(3)  
T_CRIT_A Delay  
Output Fall Time  
Conversions  
(max)  
t OF  
C L = 400 pF  
I O = 3 mA  
250  
ns (max)  
(3) For best accuracy, minimize output loading. 10k pull-ups resistors should be sufficient. Higher sink currents can affect sensor accuracy  
with internal heating. This can cause an error of 0.64 °C at full rated sink current and saturation voltage based on junction-to-ambient  
thermal resistance.  
Serial Bus Digital Switching Characteristics  
Unless otherwise noted, these specifications apply for +VS= +2.7V to +5.5V for LM92CIM . Boldface limits apply for TA = TJ  
= TMIN to TMAX; all other limits TA= TJ= +25 °C, unless otherwise noted. CL (load capacitance) on output lines = 80 pF unless  
otherwise specified. Boldface limits apply for TA = TJ = TMIN to TMAX; all other limits TA = TJ = +25 °C, unless otherwise noted.  
Typical(1)  
Limits(2) (3)  
Unit  
(Limit)  
Symbol  
t 1  
Parameter  
Conditions  
SCL (Clock) Period  
2.5  
1
µs(min)  
ms(max)  
ns(min)  
ns(min)  
ns(min)  
ns(min)  
t 2  
Data in Set-Up Time to SCL High  
100  
0
t 3  
Data Out Stable after SCL Low  
t 4  
SDA Low Set-Up Time to SCL Low (Start Condition)  
SDA High Hold Time after SCL High (Stop Condition)  
SDA and SCL Time Low for Reset of Serial Interface  
100  
100  
t 5  
(4)  
tTIMEOUT  
75  
300  
ms (min)  
ms (max)  
(1) Typical values are at TA = 25 °C and represent most likely parametric norm.  
(2) Limits are guaranteed to TI's AOQL (Average Outgoing Quality Level).  
(3) Timing specifications are tested at the bus input logic levels (Vin(0)=0.3xVA for a falling edge and Vin(1)=0.7xVA for a rising edge) when  
the SCL and SDA edge rates are similar.  
(4) Holding the SDA and/or SCL lines Low for a time interval greater than tTIMEOUT will cause the LM92 to reset SCL and SDA to the IDLE  
state of the serial bus communication (SDA and SCL set High).  
Figure 4. Serial Bus Communication  
6
Submit Documentation Feedback  
Copyright © 2000–2013, Texas Instruments Incorporated  
Product Folder Links: LM92  
LM92  
www.ti.com  
SNIS110D MARCH 2000REVISED MARCH 2013  
Figure 5. Temperature-to-Digital Transfer Function (Non-linear scale for clarity)  
Copyright © 2000–2013, Texas Instruments Incorporated  
Submit Documentation Feedback  
7
Product Folder Links: LM92  
LM92  
SNIS110D MARCH 2000REVISED MARCH 2013  
www.ti.com  
FUNCTIONAL DESCRIPTION  
The LM92 temperature sensor incorporates a band-gap type temperature sensor, 13-bit ADC, and a digital  
comparator with user-programmable upper and lower limit values. The comparator activates either the INT line  
for temperatures outside the TLOW and THIGH window, or the T_CRIT_A line for temperatures which exceed  
T_CRIT. The lines are programmable for mode and polarity.  
TEMPERATURE COMPARISON  
LM92 provides a window comparison against a lower (TLOW) and upper (THIGH) trip point. A second upper trip  
point (T_CRIT) functions as a critical alarm shutdown. Figure 7 depicts the comparison function as well as the  
modes of operation.  
Status Bits  
The internal Status bits operate as follows:  
True”: Temperature above a THIGH or T_CRIT is “true” for those respective bits. A “true” for TLOW is  
temperature below TLOW  
.
False”: Assuming temperature has previously crossed above THIGH or T_CRIT, then the temperature must  
drop below the points corresponding THYST (THIGH THYST or T_CRIT THYST) in order for the condition to be  
false. For TLOW, assuming temperature has previously crossed below TLOW, a “false” occurs when temperature  
goes above TLOW + THYST  
.
The Status bits are not affected by reads or any other actions, and always represent the state of temperature vs.  
setpoints.  
Hardwire Outputs  
The T_CRIT_A hardwire output mirrors the T_CRIT_A flag, when the flag is true, the T_CRIT_A output is  
asserted at all times regardless of mode. Reading the LM92 has no effect on the T_CRIT_A output, although the  
internal conversion is restarted.  
The behavior of the INT hardwire output is as follows:  
Comparator Interrupt Mode (Default): User reading part resets output until next measurement completes. If  
condition is still true, output is set again at end of next conversion cycle. For example, if a user never reads the  
part, and temperature goes below TLOW then INT becomes active. It would stay that way until temperature goes  
above TLOW + THYST. However if the user reads the part, the output would be reset. At the end of the next  
conversion cycle, if the condition is true, it is set again. If not, it remains reset.  
Event Interrupt Mode: User reading part resets output until next condition "event" occurs (in other words,  
output is only set once for a true condition, if reset by a read, it remains reset until the next triggering threshold  
has been crossed). Conversely, if a user never read the part, the output would stay set indefinitely after the first  
event that set the output. An “event” for Event Interrupt Mode is defined as:  
1. Transitioning upward across a setpoint, or  
2. Transitioning downward across a setpoint's corresponding hysteresis (after having exceeded that setpoint).  
For example, if a user never read the part, and temperature went below TLOW then INT would become active. It  
would stay that way forever if a user never read the part.  
However if the user read the part, the output would be reset. Even if the condition is true, it will remain reset. The  
temperature must cross above TLOW + THYST to set the output again.  
In either mode, reading any register in the LM92 restarts the conversion. This allows a designer to know exactly  
when the LM92 begins a comparison. This prevents unnecessary Interrupts just after reprogramming setpoints.  
Typically, system Interrupt inputs are masked prior to reprogramming trip points. By doing a read just after  
resetting trip points, but prior to unmasking, unexpected Interrupts are prevented.  
Avoid programming setpoints so close that their hysteresis values overlap. An example would be that with a  
THYST value of 2 °C then setting THIGH and TLOW to within 4 °C of each other will violate this restriction. To be  
more specific, with THYST set to 2 °C assume THIGH set to 64 °C. If TLOW is set equal to, or higher than 60 °C this  
restriction is violated.  
8
Submit Documentation Feedback  
Copyright © 2000–2013, Texas Instruments Incorporated  
Product Folder Links: LM92  
 
LM92  
www.ti.com  
SNIS110D MARCH 2000REVISED MARCH 2013  
DEFAULT SETTINGS  
The LM92 always powers up in a known state. LM92 power up default conditions are:  
1. Comparator Interrupt Mode  
2. TLOW set to 10 °C  
3. THIGH set to 64 °C  
4. T_CRIT set to 80 °C  
5. THYST set to 2 °C  
6. INT and T_CRIT_A active low  
7. Pointer set to “00”; Temperature Register  
The LM92 registers will always reset to these default values when the power supply voltage is brought up from  
zero volts as the supply crosses the voltage level plotted in the following curve. The LM92 registers will reset  
again when the power supply drops below the voltage plotted in this curve.  
Figure 6. Average Power on Reset Voltage vs Temperature  
SERIAL BUS INTERFACE  
The LM92 operates as a slave on the Serial Bus, so the SCL line is an input (no clock is generated by the LM92)  
and the SDA line is a bi-directional serial data line. According to Serial Bus specifications, the LM92 has a 7-bit  
slave address. The five most significant bits of the slave address are hard wired inside the LM92 and are  
“10010”. The two least significant bits of the address are assigned to pins A1–A0, and are set by connecting  
these pins to ground for a low, (0); or to +VS for a high, (1).  
Therefore, the complete slave address is:  
1
0
0
1
0
A1  
A0  
MSB  
LSB  
Copyright © 2000–2013, Texas Instruments Incorporated  
Submit Documentation Feedback  
9
Product Folder Links: LM92  
LM92  
SNIS110D MARCH 2000REVISED MARCH 2013  
www.ti.com  
Note: Event Interrupt mode is drawn as if the user is reading the part. If the user doesn't read, the outputs would go  
low and stay that way until the LM92 is read. Comparator Interrupt Mode is drawn as if the user never reads the part.  
If the user does read, the outputs will go high once read instruction is executed and, if the fault condition still exists,  
go low at the end of the next conversion.  
Figure 7. Temperature Response Diagram  
TEMPERATURE DATA FORMAT  
Temperature data can be read from the Temperature and Set Point registers; and written to the Set Point  
registers. Temperature data can be read at any time, although reading faster than the conversion time of the  
LM92 will prevent data from being updated. Temperature data is represented by a 13-bit, two's complement word  
with an LSB (Least Significant Bit) equal to 0.0625 °C:  
Table 2. Temperature Data Output  
Temperature  
Digital Output  
Binary  
Hex  
+130°C  
+125 °C  
+80 °C  
+64 °C  
+25 °C  
+10 °C  
+2 °C  
0 1000 0 010 0000  
0 0111 1101 0000  
0 0101 0000 0000  
0 0100 0000 0000  
0 0001 1001 0000  
0 0000 1010 0000  
0 0000 0010 0000  
08 20h  
07 D0h  
05 00h  
04 00h  
01 90h  
00 A0h  
00 20h  
10  
Submit Documentation Feedback  
Copyright © 2000–2013, Texas Instruments Incorporated  
Product Folder Links: LM92  
LM92  
www.ti.com  
SNIS110D MARCH 2000REVISED MARCH 2013  
Table 2. Temperature Data Output (continued)  
Temperature  
Digital Output  
Binary  
Hex  
+0.0625 °C  
0 °C  
0 0000 0000 0001  
00 0000 0000  
00 01h  
00 00h  
1F FFh  
1E 70h  
1C 90h  
0.0625 °C  
25 °C  
1 1111 1111 1111  
1 1110 0111 0000  
1 1100 1001 0000  
55 °C  
SHUTDOWN MODE  
Shutdown mode is enabled by setting the shutdown bit in the Configuration register via the Serial Bus. Shutdown  
mode reduces power supply current to 5 µA typical. T_CRIT_A is reset if previously set. Since conversions are  
stopped during shutdown, T_CRIT_A and INT will not be operational. The Serial Bus interface remains active.  
Activity on the clock and data lines of the Serial Bus may slightly increase shutdown mode quiescent current.  
Registers can be read from and written to in shutdown mode. The LM92 takes milliseconds to respond to the  
shutdown command.  
INT AND T_CRIT_A OUTPUT  
The INT and T_CRIT_A outputs are open-drain outputs and do not have internal pull-ups. A "high" level will not  
be observed on these pins until pull-up current is provided from some external source, typically a pull-up resistor.  
Choice of resistor value depends on many system factors but, in general, the pull-up resistor should be as large  
as possible. This will minimize any errors due to internal heating of the LM92. The maximum resistance of the  
pull up, based on LM92 specification for High Level Output Current, to provide a 2 volt high level, is 30K ohms.  
FAULT QUEUE  
A fault queue of 4 faults is provided to prevent false tripping when the LM92 is used in noisy environments. The 4  
faults must occur consecutively to set flags as well as INT and T_CRIT_A outputs. The fault queue is enabled by  
setting bit 4 of the Configuration Register high (see CONFIGURATION REGISTER ).  
Copyright © 2000–2013, Texas Instruments Incorporated  
Submit Documentation Feedback  
11  
Product Folder Links: LM92  
 
LM92  
SNIS110D MARCH 2000REVISED MARCH 2013  
www.ti.com  
INTERNAL REGISTER STRUCTURE  
Figure 8.  
There are four data registers in the LM92, selected by the Pointer register. At power-up the Pointer is set to “00”;  
the location for the Temperature Register. The Pointer register latches the last location it was set to. In Interrupt  
Mode, a read from the LM92 resets the INT output. Placing the device in Shutdown mode resets the INT and  
T_CRIT_A outputs. All registers are read and write, except the Temperature register which is read only.  
A write to the LM92 will always include the address byte and the Pointer byte. A write to the Configuration  
register requires one data byte, while the TLOW, THIGH, and T_CRIT registers require two data bytes.  
Reading the LM92 can take place either of two ways: If the location latched in the Pointer is correct (most of the  
time it is expected that the Pointer will point to the Temperature register because it will be the data most  
frequently read from the LM92), then the read can simply consist of an address byte, followed by retrieving the  
corresponding number of data bytes. If the Pointer needs to be set, then an address byte, pointer byte, repeat  
start, and another address byte plus required number of data bytes will accomplish a read.  
The first data byte is the most significant byte with most significant bit first, permitting only as much data as  
necessary to be read to determine the temperature condition. For instance, if the first four bits of the temperature  
data indicates a critical condition, the host processor could immediately take action to remedy the excessive  
temperature. At the end of a read, the LM92 can accept either Acknowledge or No Acknowledge from the Master  
(No Acknowledge is typically used as a signal for the slave that the Master has read its last byte).  
An inadvertent 8-bit read from a 16-bit register, with the D7 bit low, can cause the LM92 to stop in a state where  
the SDA line is held low as shown in Figure 9. This can prevent any further bus communication until at least 9  
additional clock cycles have occurred. Alternatively, the master can issue clock cycles until SDA goes high, at  
which time issuing a “Stop” condition will reset the LM92.  
12  
Submit Documentation Feedback  
Copyright © 2000–2013, Texas Instruments Incorporated  
Product Folder Links: LM92  
LM92  
www.ti.com  
SNIS110D MARCH 2000REVISED MARCH 2013  
Figure 9. Inadvertent 8-Bit Read from 16-Bit Register where D7 is Zero (“0”)  
POINTER REGISTER  
(Selects which registers will be read from or written to):  
P7  
P6  
P5  
P4  
P3  
P2  
P1  
P0  
0
0
0
0
0
Register Select  
P0–P2: Register Select:  
P2  
0
P1  
0
P0  
0
Register  
Temperature (Read only) (Power-up default)  
Configuration (Read/Write)  
THYST (Read/Write)  
0
0
1
0
1
0
0
1
1
T_CRIT (Read/Write)  
1
0
0
TLOW (Read/Write)  
1
0
1
THIGH (Read/Write)  
1
1
1
Manufacturer's ID  
P3–P7: Must be kept zero.  
TEMPERATURE REGISTER  
Table 3. (Read Only):  
D15  
D14  
D13  
D12  
D11  
D10  
D9  
D8  
D7  
D6  
D5  
D4  
D3  
D2  
D1  
D0  
Sign  
MSB  
Bit 10  
Bit 9  
Bit 8  
Bit 7  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
Bit 0  
CRIT  
HIGH  
LOW  
Status Bits  
D0–D2: Status Bits  
D3–D15: Temperature Data. One LSB = 0.0625°C. Two's complement format.  
CONFIGURATION REGISTER  
Table 4. (Read/Write):  
D7  
D6  
D5  
D4  
D3  
D2  
D1  
INT Mode  
D0  
0
0
0
Fault Queue  
INT Polarity  
T_CRIT_A  
Polarity  
Shutdown  
D0: Shutdown - When set to 1 the LM92 goes to low power shutdown mode. Power up default of “0”.  
D1: Interrupt mode - 0 is Comparator Interrupt mode, 1 is Event Interrupt mode. Power up default of “0”.  
D2, D3: T_CRIT_A and INT Polarity - 0 is active low, 1 is active high. Outputs are open-drain. Power up default  
of “0”  
D4: Fault Queue - When set to 1 the Fault Queue is enabled, see FAULT QUEUE. Power up default of “0”.  
D5–D7: These bits are used for production testing and must be kept zero for normal operation.  
Copyright © 2000–2013, Texas Instruments Incorporated  
Submit Documentation Feedback  
13  
Product Folder Links: LM92  
LM92  
SNIS110D MARCH 2000REVISED MARCH 2013  
www.ti.com  
THYST, TLOW, THIGH AND T_CRIT_A REGISTERS  
Table 5. (Read/Write):  
D15  
D14  
D13  
D12  
D11  
D10  
D9  
D8  
D7  
D6  
D5  
D4  
D3  
D2  
D1  
D0  
Sign  
MSB  
Bit 10  
Bit 9  
Bit 8  
Bit7  
Bit6  
Bit5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
Bit 0  
X
X
X
D0–D2: Undefined  
D3–D15: THYST, TLOW, THIGH or T_CRIT Trip Temperature Data. Power up default is TLOW = 10°C, THIGH = 64°C,  
T_CRIT = 80°C, THYST = 2°C.  
THYST is subtracted from THIGH, and T_CRIT, and added to TLOW  
.
Avoid programming setpoints so close that their hysteresis values overlap. See TEMPERATURE COMPARISON.  
Manufacturer's Identification Register  
Table 6. (Read only):  
D15  
D14  
D13  
D12  
D11  
D10  
D9  
D8  
D7  
D6  
D5  
D4  
D3  
D2  
D1  
D0  
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
D0–D15: Manufactures ID.  
14  
Submit Documentation Feedback  
Copyright © 2000–2013, Texas Instruments Incorporated  
Product Folder Links: LM92  
LM92  
www.ti.com  
SNIS110D MARCH 2000REVISED MARCH 2013  
I2C TIMING DIAGRAMS  
Figure 10. Typical 2-Byte Read From Preset Pointer Location Such as Temp or Comparison Registers  
Figure 11. Typical Pointer Set Followed by Immediate Read for 2-Byte Register such as Temp or  
Comparison Registers  
Figure 12. Typical 1-Byte Read from Configuration Register with Preset Pointer  
Figure 13. Typical Pointer Set Followed by Immediate Read from Configuration Register  
Figure 14. Configuration Register Write  
Figure 15. Comparison Register Write  
Copyright © 2000–2013, Texas Instruments Incorporated  
Submit Documentation Feedback  
15  
Product Folder Links: LM92  
LM92  
SNIS110D MARCH 2000REVISED MARCH 2013  
www.ti.com  
APPLICATION HINTS  
The temperature response graph in Figure 16 depicts a typical application designed to meet ACPI requirements.  
In this type of application, the temperature scale is given an arbitrary value of "granularity", or the window within  
which temperature notification events should occur. The LM92 can be programmed to the window size chosen by  
the designer, and will issue interrupts to the processor whenever the window limits have been crossed. The  
internal flags permit quick determination of whether the temperature is rising or falling.  
The T_CRIT limit would typically use its separate output to activate hardware shutdown circuitry separate from  
the processor. This is done because it is expected that if temperature has gotten this high that the processor may  
not be responding. The separate circuitry can then shut down the system, usually by shutting down the power  
supply.  
Note that the INT and T_CRIT_A outputs are separate, but can be wire-ORed together. Alternatively the  
T_CRIT_A can be diode ORed to the INT line in such a way that a T_CRIT_A event activates the INT line, but an  
INT event does not activate the T_CRIT_A line. This may be useful in the event that it is desirable to notify both  
the processor and separate T_CRIT_A shutdown circuitry of a critical temperature alarm at the same time  
(maybe the processor is still working and can coordinate a graceful shutdown with the separate shutdown  
circuit).  
To implement ACPI compatible sensing it is necessary to sense whenever the temperature goes outside the  
window, issue an interrupt, service the interrupt, and reprogram the window according to the desired granularity  
of the temperature scale. The reprogrammed window will now have the current temperature inside it, ready to  
issue an interrupt whenever the temperature deviates from the current window.  
To understand this graph, assume that at the left hand side the system is at some nominal temperature. For the  
1st event temperature rises above the upper window limit, THIGH, causing INT to go active. The system responds  
to the interrupt by querying the LM92's status bits and determines that THIGH was exceeded, indicating that  
temperature is rising. The system then programs the temperature limits to a value higher by an amount equal to  
the desired granularity. Note that in Event Interrupt Mode, reprogramming the limits has caused a second,  
known, interrupt to be issued since temperature has been returned within the window. In Comparator Interrupt  
Mode, the LM92 simply stops issuing interrupts.  
The 2nd event is another identical rise in temperature. The 3rd event is typical of a drop in temperature. This is  
one of the conditions that demonstrates the power of the LM92, as the user receives notification that a lower limit  
is exceeded in such a way that temperature is dropping.  
The Critical Alarm Event activates the separate T_CRIT_A output. Typically, this would feed circuitry separate  
from the processor on the assumption that if the system reached this temperature, the processor might not be  
responding.  
16  
Submit Documentation Feedback  
Copyright © 2000–2013, Texas Instruments Incorporated  
Product Folder Links: LM92  
LM92  
www.ti.com  
SNIS110D MARCH 2000REVISED MARCH 2013  
Note: Event Interrupt mode is drawn as if the user is reading the part. If the user doesn't read, the outputs would go  
low and stay that way until the LM92 is read.  
Figure 16. Temperature Response Diagram for ACPI Implementation  
Typical Applications  
Figure 17. Typical Application  
Copyright © 2000–2013, Texas Instruments Incorporated  
Submit Documentation Feedback  
17  
Product Folder Links: LM92  
LM92  
SNIS110D MARCH 2000REVISED MARCH 2013  
www.ti.com  
Figure 18. Remote HVAC temperature sensor communicates via 3 wires, including thermostat signals  
Figure 19. ACPI Compatible Terminal Alarm Shutdown  
By powering the LM92 from auxiliary output of the power supply, a non-functioning overheated computer can be  
powered down to preserve as much of the system as possible.  
18  
Submit Documentation Feedback  
Copyright © 2000–2013, Texas Instruments Incorporated  
Product Folder Links: LM92  
 
LM92  
www.ti.com  
SNIS110D MARCH 2000REVISED MARCH 2013  
REVISION HISTORY  
Changes from Revision C (March 2013) to Revision D  
Page  
Changed layout of National Data Sheet to TI format .......................................................................................................... 18  
Copyright © 2000–2013, Texas Instruments Incorporated  
Submit Documentation Feedback  
19  
Product Folder Links: LM92  
PACKAGE OPTION ADDENDUM  
www.ti.com  
1-Nov-2013  
PACKAGING INFORMATION  
Orderable Device  
LM92CIM  
Status Package Type Package Pins Package  
Eco Plan  
Lead/Ball Finish  
MSL Peak Temp  
Op Temp (°C)  
-55 to 150  
-55 to 150  
-55 to 150  
-55 to 150  
Device Marking  
Samples  
Drawing  
Qty  
(1)  
(2)  
(6)  
(3)  
(4/5)  
NRND  
SOIC  
SOIC  
SOIC  
SOIC  
D
8
8
8
8
95  
TBD  
Call TI  
CU SN  
Call TI  
CU SN  
Call TI  
LM92  
CIM  
LM92CIM/NOPB  
LM92CIMX  
ACTIVE  
NRND  
D
D
D
95  
Green (RoHS  
& no Sb/Br)  
Level-1-260C-UNLIM  
Call TI  
LM92  
CIM  
2500  
2500  
TBD  
LM92  
CIM  
LM92CIMX/NOPB  
ACTIVE  
Green (RoHS  
& no Sb/Br)  
Level-1-260C-UNLIM  
LM92  
CIM  
(1) The marketing status values are defined as follows:  
ACTIVE: Product device recommended for new designs.  
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.  
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design.  
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.  
OBSOLETE: TI has discontinued the production of the device.  
(2) Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability  
information and additional product content details.  
TBD: The Pb-Free/Green conversion plan has not been defined.  
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that  
lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.  
Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between  
the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above.  
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight  
in homogeneous material)  
(3) MSL, Peak Temp. - The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature.  
(4) There may be additional marking, which relates to the logo, the lot trace code information, or the environmental category on the device.  
(5) Multiple Device Markings will be inside parentheses. Only one Device Marking contained in parentheses and separated by a "~" will appear on a device. If a line is indented then it is a continuation  
of the previous line and the two combined represent the entire Device Marking for that device.  
(6) Lead/Ball Finish - Orderable Devices may have multiple material finish options. Finish options are separated by a vertical ruled line. Lead/Ball Finish values may wrap to two lines if the finish  
value exceeds the maximum column width.  
Addendum-Page 1  
PACKAGE OPTION ADDENDUM  
www.ti.com  
1-Nov-2013  
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information  
provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and  
continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals.  
TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release.  
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis.  
Addendum-Page 2  
PACKAGE MATERIALS INFORMATION  
www.ti.com  
26-Mar-2013  
TAPE AND REEL INFORMATION  
*All dimensions are nominal  
Device  
Package Package Pins  
Type Drawing  
SPQ  
Reel  
Reel  
A0  
B0  
K0  
P1  
W
Pin1  
Diameter Width (mm) (mm) (mm) (mm) (mm) Quadrant  
(mm) W1 (mm)  
LM92CIMX  
SOIC  
SOIC  
D
D
8
8
2500  
2500  
330.0  
330.0  
12.4  
12.4  
6.5  
6.5  
5.4  
5.4  
2.0  
2.0  
8.0  
8.0  
12.0  
12.0  
Q1  
Q1  
LM92CIMX/NOPB  
Pack Materials-Page 1  
PACKAGE MATERIALS INFORMATION  
www.ti.com  
26-Mar-2013  
*All dimensions are nominal  
Device  
Package Type Package Drawing Pins  
SPQ  
Length (mm) Width (mm) Height (mm)  
LM92CIMX  
SOIC  
SOIC  
D
D
8
8
2500  
2500  
367.0  
367.0  
367.0  
367.0  
35.0  
35.0  
LM92CIMX/NOPB  
Pack Materials-Page 2  
IMPORTANT NOTICE  
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other  
changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest  
issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and  
complete. All semiconductor products (also referred to herein as “components”) are sold subject to TI’s terms and conditions of sale  
supplied at the time of order acknowledgment.  
TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI’s terms  
and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary  
to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily  
performed.  
TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and  
applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide  
adequate design and operating safeguards.  
TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or  
other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information  
published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or  
endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the  
third party, or a license from TI under the patents or other intellectual property of TI.  
Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration  
and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered  
documentation. Information of third parties may be subject to additional restrictions.  
Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service  
voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice.  
TI is not responsible or liable for any such statements.  
Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements  
concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support  
that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which  
anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause  
harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use  
of any TI components in safety-critical applications.  
In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI’s goal is to  
help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and  
requirements. Nonetheless, such components are subject to these terms.  
No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties  
have executed a special agreement specifically governing such use.  
Only those TI components which TI has specifically designated as military grade or “enhanced plastic” are designed and intended for use in  
military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components  
which have not been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and  
regulatory requirements in connection with such use.  
TI has specifically designated certain components as meeting ISO/TS16949 requirements, mainly for automotive use. In any case of use of  
non-designated products, TI will not be responsible for any failure to meet ISO/TS16949.  
Products  
Applications  
Audio  
www.ti.com/audio  
amplifier.ti.com  
dataconverter.ti.com  
www.dlp.com  
Automotive and Transportation www.ti.com/automotive  
Communications and Telecom www.ti.com/communications  
Amplifiers  
Data Converters  
DLP® Products  
DSP  
Computers and Peripherals  
Consumer Electronics  
Energy and Lighting  
Industrial  
www.ti.com/computers  
www.ti.com/consumer-apps  
www.ti.com/energy  
dsp.ti.com  
Clocks and Timers  
Interface  
www.ti.com/clocks  
interface.ti.com  
logic.ti.com  
www.ti.com/industrial  
www.ti.com/medical  
Medical  
Logic  
Security  
www.ti.com/security  
Power Mgmt  
Microcontrollers  
RFID  
power.ti.com  
Space, Avionics and Defense  
Video and Imaging  
www.ti.com/space-avionics-defense  
www.ti.com/video  
microcontroller.ti.com  
www.ti-rfid.com  
www.ti.com/omap  
OMAP Applications Processors  
Wireless Connectivity  
TI E2E Community  
e2e.ti.com  
www.ti.com/wirelessconnectivity  
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265  
Copyright © 2013, Texas Instruments Incorporated  

相关型号:

LM92CIMX

【0.33∑C Accurate, 12-Bit Sign Temperature Sensor and Thermal Window Comparator with Two-Wire Interface
NSC

LM92CIMX

0.33 Accurate, 12-Bit Sign Temperature Sensor and Thermal Window Comparator With Two-Wire Interface
TI

LM92CIMX/NOPB

Switch/Digital Output Temperature Sensor, DIGITAL TEMP SENSOR-SERIAL, 13BIT(s), 1.50Cel, RECTANGULAR, SURFACE MOUNT, 0.150 INCH, PLASTIC, SOP-8
NSC

LM92CIMX/NOPB

±0.5&deg;C Temperature Sensor with Alert Function and I2C/SMBus Interface 8-SOIC -55 to 150
TI

LM92_05

【0.33∑C Accurate, 12-Bit + Sign Temperature Sensor and Thermal Window Comparator with Two-Wire Interface
NSC

LM93

Hardware Monitor with Integrated Fan Control for Server Management
NSC

LM93

具有 2 条远程和 1 条本地通道的温度传感器,带硬件监控器和 16 个电源电压监控器
TI

LM93CIMT

Hardware Monitor with Integrated Fan Control for Server Management
NSC

LM93CIMT

Hardware Monitor with Integrated Fan Control for Server Management 56-TSSOP 0 to 85
TI

LM93CIMT/NOPB

IC 16-CHANNEL POWER SUPPLY SUPPORT CKT, PDSO56, MO-153EE, TSSOP-56, Power Management Circuit
NSC

LM93CIMT/NOPB

Hardware Monitor with Integrated Fan Control for Server Management
TI

LM93CIMTX

Hardware Monitor with Integrated Fan Control for Server Management
NSC